Sei sulla pagina 1di 2

STRUCTURAL DESIGN CALCULATION

Part : Wind load Calculation


Project : Bldg-2A, 2B

Date

Calculation of Wind Load


1)

09-May-16

(As per IS 875-Part3 :1987)

Basic Site Data


Height of wall

He

16.3 m

Length of wall in plan


Width of wall in plan

L
B

:
:

97.4 m
12.2 m

basic wind speed (mean hourly)

Vb

Terrain Category
Class of building
2)

33

m/s

118.8 km/hr

: Category-2
: Class C

Dynamic Pressure (q s )
pz
VZ
where,
Vz
Vb
k1
k2

k3

2
: 0.6 VZ
: V b x k1 x k 2 x k 3

(sec-5.4)
(sec-5.3)

Design wind speed


Basic wind speed
Risk coefficient for different classes of structure as per Table-1
k1
: 1.00
Factor as per Table-2
k2
: 0.93
Topography factor
k3
: 1.00

: 33 x 1 x 0.93 x 1
:

Dynamic pressure,
pz

30.69 m/s

: 0.6 x (30.69)^2
2
: 565.1 N/m

X direction
Wind
Pressure

Pww

(Table - 2)
(Sec- 5.3.3)

Therefore,
VZ

(Table - 1)

PLw

0.7
-0.3
0.396 -0.17

Psw
-0.7
-0.40

STRUCTURAL DESIGN CALCULATION


Part : Wind load Calculation
Project : Bldg-2A, 2B

Z direction

Wind
Pressure

Date

Pww

PLw

Psw

0.7
0.396

-0.1
-0.06

-0.5
-0.28

09-May-16

Potrebbero piacerti anche