Eguard commissioning for


LTE

ZTE

Document
revision no
R 1.0
R 2.0

Revised on
Resion for revision
2015/3/20 first draft
2015/5/6 change channel

ZTE

Content
1.Check EISU flash light ................................................................................................................... 4
2.Check alarm data through EISUconfig software .......................................................................... 4
3.How to debug door sensor and Bell Ring..................................................................................... 5
4.How to check smoke sensor ........................................................................................................ 7
5.How to check temperature sensor .............................................................................................. 9
6.How to check ground cut ........................................................................................................... 11
7.How to check DC Fan ................................................................................................................. 12
8.How to check IIC(infared air-condition controller) .................................................................... 13
9.How to set rectifier .................................................................................................................... 17
1.outdoor site........................................................................................................................ 17
2.Indoor site .......................................................................................................................... 18
10.How to check the comunication from EISU to BBU ................................................................. 19
11.How to check Card Holder ....................................................................................................... 22
12.How to check battery&feeder theft GND cut& AC remove & Phase and arrestor Failure ...... 25
13.Below Is For Add sensor site .................................................................................................... 28
1. you should remove the lid of EISU , and make the below S1-7 to on ........................... 28
2.Before config the channel In the board , you must stop the public module , follow the
next picture.(if no have this module just ignore) ........................................................... 29
3.set add sensor channel ...................................................................................................... 30
14.HOW TO Check add Sensor site sensor................................................................................... 31
1.temperature Sensor ........................................................................................................... 31
2.Smoke sensor ..................................................................................................................... 33
3.Door magnistor .................................................................................................................. 34
4.the battery theft and feeder theft are same ..................................................................... 36

ZTE

The first part is for new site


TESTING EISU
There are two methods to check all sensor in site, those are :
1. Check the EISU green flash light from EISU
2. Check alarm data through EISUconfig software

1.Check EISU flash light


IF EISU communication normal, the RUN light will be flash.

2.Check alarm data through EISUconfig software

Connect LAN cable between host computer and EISU through network port
Set up host computer IP address to get into same network with EISU ( EISU default
server IP address is 10.72.88.80 ), the last two number can be any number, but cant
be same as EISU.
Open configuration program EISUCONFIG, password : 11111111, Click Scan Server IP
and double click the IP to be configured.

ZTE

3.How to debug door sensor and Bell Ring

ZTE

A. Open the door , EISU light ALRM1 flash. Close the door, alarm disappear.
B. Check from EISUconfig, DI50 channel alarm become 0.The chanel DI 50 for door sensor .

ZTE

4.How to check smoke sensor

A. Press the black button on smoke sensoralarm bell ringing

ZTE
B. Blow the smoke sensor with cigarette smoke, DI13 channel alarm become 1

C. Vanish smoke alarm

Select BOARD DO Parameter table , DO number 305 fill in channel field. Control way :
Pulse, Click DO Control button.

ZTE

5.How to check temperature sensor

A. Touch the IIC board with hand ( a black probedetector)or burn a lighter near IIC board
sensor ,the alarm data for AI-49 is dynamic and always change every time

ZTE

Before the IIC sensor is given some heat from lighter or hand touch

After the IIC sensor is given some heat from lighter or hand touch

ZTE

6.How to check ground cut

A. Pull out X3 socket from EISU alarm appear, connect it to EISU alarm
disappear.

ZTE

7.How to check DC Fan

Open BOARD DO PARAMETER table in BOARD MANAGEMENT tab.


The DO channel number for DCFan is 302. Change the control way into High level to turn ON
the DC fan. Change the control way into low level to turn OFF the DC Fan.

2.4
2.5

ZTE

8.How to check IIC(infared air-condition controller)


(infared air-condition controller) the following steps cannot used To DaiKin Aircondition . And DaiKin air-condition have the special operation. Refer DaiKin
Aircondition IIC

A How to study order from AC (The IIC equal AC controller )


If the IIC is studing from AC ,the IIC is similar AC controller

If the IIC connect 2 AC ,The pin for 1 set off .

ZTE

If the IIC connent 1 AC ,The Pin for 2 set off

How to study from Air-conditioner by IIC .


C touth the button ,the data become 0-6

ZTE

0----turn on
1----turn up
2----turn up
3--------turn up
4----turn down
5-----turn down
6-----turn off
d how to test the IIC whether to contro the AC .

ZTE

2.6 How to check from IIC to AC


A check the communication from IIC to EISU whether is ok or not .
DI-9000 is 0
DI-6000 is 0
DI-3000 is 0,
The meaning for 0meaning is ok , the meaning for 1has something wrong
for communication from IIC to EISU .
If IIC connet 1 air-conditioner ,Set the pin for 2 off
If IIC connet 2 air-conditioner ,Set the pin for 1 off
Pls check the communication by software .DI-9000,DI-6000,DI-3000 is 0 .

ZTE

9.How to set rectifier


1.outdoor site:
1.
2.
3.
4.

see to display rectifer choose CTR parameter push enter


2.choose pass 0000_ move the flash to right _ and push enter
System setting----- 1104 para setting to wireless
check the rectifier data from EISUconfig software

0063

if the rectfier CSU have DB 9 head , no need do the


following operation.

ZTE

2.Indoor site (only ZXDU 58 need set and Rect ZXDU68 S301 no
need)
1.see to display rectifer choose CTR parameter push enter
2.choose pass 0000_ move the flash to right _ and push enter
0063
3.enter setup parameter go to 13 and 15 ; 13 seting 9600 15 seting device addr to 001
4 check the rectifier data from EISUconfig software .

ZTE

10.How to check the comunication from EISU to BBU .

ZTE

ZTE
How to check the communication from EISU to BTS whether is ok or not .
1. Only measure the voltage from R(Rx) and Ground is about 4.70 V.
and measure from S(Tx) to Ground is 7.14 V (Look pictures below)

ZTE

11.How to check Card Holder

ZTE

To see/seting access control must be use new software (eisu v1.10.016CDMA).

ZTE
Click softTrans than click read than click set until the display show sensor

ZTE

12.How to check battery&feeder theft GND cut& AC remove &


Phase and arrestor Failure
The Following the the battery&feeder theft and GND cut and AC outdoor part unit & pahse
failure and arrestor failure is same . and the batery theft chanel is 9, feeder theft chanel is 10,
AC outdoor part channel is 11, GND cut is 12, and phase failure channel is 4, arrestor failure
is 5. Like the following channel 9 testing
Before testing make sure the following channel is correct

1) plug the cable in no alarm

ZTE

2) plug out the cable the alarm show

ZTE

ZTE

13.Below Is For Add sensor site

1. you should remove the lid of EISU ,


and make the below S1-7 to on

ZTE

2.Before config the channel In the board , you must stop the
public module , follow the next picture.(if no have this module
just ignore)
The second module in the Read ALL Module Information must be stopped.

ZTE

3.set add sensor channel


Set 2 as smoke sensor , 3 as door magnistor, 7 as digital temperature ,8 as battery theft . 9 as
feeder theft , this five channel setting must follow the next picture
After finish configuration click Set Channels para to save, Next follow the outdoor test these
five channel 2 3 7 8 9, you can reference the outdoor DOC

ZTE

14.HOW TO Check add Sensor site sensor

1.temperature Sensor
1) the temperature value is dynamic change ,channle 7 AI -7

ZTE

ZTE

2.Smoke sensor

Press the black button on the smoke sensor , alarm appear.

2) press again the alarm vanish

ZTE

3.Door magnistor
1) open the door , the alarm show

ZTE

2close the door the alarm vanish

ZTE

4.the battery theft and feeder theft are same


1) plug the cable in no alarm

2) plug out the cable the alarm show

ZTE