Using the formula in accordance with the rules mentioned above, the smallest flow area Ao shall be calculated to
discharge the required mass flow. The flow area selected shall be equal to or larger than the required one. A substantial
over sizing shall be avoided e.g. by fitting a lift stopper.
We have the equation,
(i) Capacity calculation for (saturated or
superheated) steam at critical flow
Qm = 0.2883 C A Kdr Po
n
Qm
M
ZTo
Po C Kdr
Qm
0.2883 C Kdr
Po
n
Po
n
Description
Flow area of a safety valve (not curtain area)
Function of the isentropic exponent
Theoretical capacity correction factor for subcritical flow
Coefficient of discharge*
Certified derated coefficient of discharge (Kd x 0.9)*
Viscosity correction factor
Isentropic exponent
Molar Mass
Number of tests
Relieving pressure
Back pressure
Critical pressure
Mass flow rate
Theoretical specific discharge capacity
Specific discharge capacity determined by tests
Universal gas constant
Relieving temperature
Critical temperature
Dynamic viscosity
Specific volume at actual relieving pressure and temperature
Dryness fraction of wet steam at the valve inlet at actual relieving pressure and temperature**
Compressibility factor at actual relieving pressure and temperature.
* Kd and Kdr are expressed as 0.xxx.
C = 3.948
Unit
mm
kg/kmol
bar (abs.)
bar (abs.)
bar (abs.)
kg/h
kg/(h.mm)
kg/(h.mm)
K
K
Pa.s
m/kg
2 (k + 1) / (k 1)
k+1
** x is expressed as 0.xx.
7/01
Sizing
The equations are used to calculate the required discharge area for a Safety Valve. The selected Safety Valve shall
have an effective (flow) area, in accordance with the corresponding orifice letter, equal to or larger than that of the
required area.
Orifice Letter
D
E
F
G
H
J
K
L
M
N
P
Q
R
T
Effective area
in
mm
0.110
71.0
0.196
126.5
0.307
198.1
0.503
324.5
0.785
506.5
1.287
830.3
1.838
1185.8
2.853
1840.6
3.600
2322.6
4.340
2800.0
6.380
4116.1
11.050
7129.0
16.000
10322.6
26.000
16774.2
Standard size *
(inlet & outlet) inches
1x2
1x2
1 x 2
1 x 3
1 x 3
2x3
3x4
3x4
4x6
4x6
4x6
6x8
6 x 10
8 x 10
NOTE
* Please refer to page 7/06 also for any revision in size due to different pressure & temperature.
NOTE
where,
A
W
Z
T
C
Kd
Kb
P
M
1. The derating factor of 0.9 may be considered (as stated in ASME Sec.VIII, Div. 1, UG-131) while arriving at the Orifice Area.
2. Coefficient of discharge, Kd to be considered as 0.975 as stated in ASME Sec.VIII, Div. 1.
3. Overpressure to be considered as 10% or 3 psig whichever is greater.
4. The factor C is based on cp/cv (k) and the value can be obtained from the following table:
7/02
Sizing
k
1.01
1.02
1.04
1.06
1.08
1.10
1.12
1.14
1.16
1.18
1.20
1.22
1.24
Constant
C
343
345
347
349
351
352
354
356
358
359
361
363
364
k
1.26
1.28
1.30
1.32
1.34
1.36
1.38
1.40
1.42
1.44
1.46
1.48
1.50
k
1.52
1.54
1.56
1.58
1.60
1.62
1.64
1.66
1.68
1.70
1.80
2.00
2.20
Constant
C
366
368
369
371
372
374
376
377
379
380
387
400
412
Pao
-------Po
2
--------k+1
k
------k-1
k
--------- x r
k-1
2
--k
k-1
1 - r ------Pao
x ----------- k and r = -------1-r
Po
where,
A = Calculated Orifice Area, in
Wt = Required Relieving Capacity, lb/h
P = Absolute Pressure, psia = Set Pressure + Overpressure + 14.7
Pd = Back Pressure, psia
w = Specific Weight, lb/ft.
Kd = Coefficient of discharge
NOTE
1. The derating factor of 0.9 may be considered (as stated in ASME Sec. VIII, Div. 1, UG-131) while arriving at the Orifice Area.
2. Coefficient of discharge, Kd to be considered as 0.65 as per API RP-520.
3. Overpressure to be considered as 10% or 3 psig whichever is greater.
7/03
Sizing
Wt
A = ----------------------------------------2407 [(P - Pd) x w] x Kd x Kv
Q (2800 G)
R = ---------------m x A'
12700 Q
R = --------------U A'
NOTE
1.
2.
3.
4.
5.
The derating factor of 0.9 may be considered (as stated in ASME Sec. VIII, Div. 1, UG-131) while arriving at the orifice area.
Coefficient of discharge, Kd to be considered as 0.65 as per API RP-520.
Overpressure to be considered as 10% or 3 psig whichever is greater.
The viscosity has to be specified in only ONE of the TWO above referred units.
For viscosity correction factor Kv, refer to the following graph.
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
101
102
103
104
105
R= Reynold's Number
7/04
Sizing
In the formula for determining the total heat absorption, the thickness of the refractory insulation is represented by the
environment factor, F.
where:
Formula Used,
Q = Total heat absorption, Btu/h
F = Environment factor for the insulation thickness
0.82
Q = 21000 x F x A 3
= 1.0 for Bare Vessel
Q
= 0.3 for vessel with 25mm insulating thickness
W = -------= 0.15 for vessel with 50mm insulating thickness
L
= 0.075 for vessel with 100 mm insulating
thickness
= 0.03 for Earth covered vessel above ground
= 0.0 for underground storage vessel
A3 = Total wetted surface of vessel, ft
W = Mass flow to be discharged by Safety Valve,
where,
A = Calculated Orifice Area, in
W = Flow rate, lb/h
P = Absolute Pressure, psia = Set Pressure + Overpressure + 14.7
Kd = Coefficient of discharge = 0.975
KSH =1, for saturated steam.
(Correction factor for Superheated steam: to be obtained from table)
W
A = -----------------------51.5 x P x Kd x KSH
psi g
15
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
350
400
500
600
800
1000
1250
1500
1750
2000
2500
3000
300
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
400
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
500
0.93
0.93
0.93
0.93
0.93
0.94
0.94
0.94
0.94
0.94
0.95
0.95
0.95
0.95
0.96
0.96
0.96
0.96
0.96
0.97
1.00
1.00
1.00
600
0.88
0.88
0.88
0.88
0.88
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.90
0.90
0.90
0.90
0.90
0.91
0.92
0.92
0.95
0.96
0.97
1.00
1.00
1.00
1.00
Pound/Inch units
Temperature in F
700
800
0.84
0.80
0.84
0.80
0.84
0.81
0.84
0.81
0.84
0.81
0.84
0.81
0.84
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.85
0.81
0.86
0.82
0.86
0.82
0.86
0.82
0.87
0.82
0.88
0.83
0.89
0.84
0.91
0.85
0.93
0.86
0.94
0.86
0.95
0.86
0.95
0.85
1.00
0.82
900
0.77
0.77
0.77
0.77
0.77
0.77
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.79
0.79
0.79
0.80
0.81
0.81
0.80
0.78
0.74
1000
0.74
0.74
0.74
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.76
0.76
0.77
0.77
0.77
0.76
0.73
0.69
1100
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.73
0.73
0.73
0.73
0.74
0.74
0.73
0.72
0.69
0.65
1200
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.71
0.71
0.71
0.70
0.69
0.66
0.62
7/05
Sizing
Valve Sizes / Flange Rating w.r.t. Set Pressure & Temperature (acc. to API 526)
Set Pressure & Flange Rating for Temp. up to
REVISED
Temp. up to
Sl.
No.
API Standard
100 F
450 F
800 F
1000 F
Orifice
Size
Flange (37.8 C) (232.2 C)(426.7 C) (538 C)
Letter inches Rating
Set press. Set press. Set press. Set press.
kg/cm2(g) kg/cm2(g)kg/cm2(g) kg/cm2(g)
D, E
1X2
1X2
1X2
1.5 X 2
1.5 X 2
1.5 X 2
1.5 X 3
1.5 X 3
1.5 X 3
1.5 X 3
1.5 X 3
1.5 X 3
AXA
BXA
CXA
AXA
BXA
CXA
AXA
BXA
CXA
DXB
AXA
BXA
20.04
52.04
104.07
20.04
52.04
104.07
20.04
52.04
104.07
156.02
20.04
20.04
13.01
43.25
86.85
13.01
43.25
86.85
13.01
43.25
86.85
129.75
13.01
20.04
5.62
35.86
71.38
5.62
35.86
71.38
5.62
35.86
71.38
107.24
5.62
20.04
----15.82
31.29
----15.82
31.29
----15.82
31.29
47.12
---------
2X3
2X3
AXA
BXA
20.04
20.04
13.01
20.04
5.62
20.04
---------
3X4
3X4
3X4
3X4
3X4
AXA
BXA
CXA
AXA
BXA
20.04
20.04
104.08
20.04
20.04
13.01
43.25
86.85
13.01
20.04
5.62
35.86
58.02
5.62
20.04
----15.82
15.82
---------
10
11
12
13
AXA
BXA
CXA
----AXA
BXA
CXA
DXA
AXA
BXA
CXA
DXA
AXA
BXA
CXA
AXA
BXA
AXA
BXA
20.04
52.04
77.35
----20.04
52.04
70.32
---20.04
36.92
70.32
----11.60
21.10
42.19
7.03
7.03
4.57
21.10
13.01
43.25
71.15
----13.01
43.25
70.32
----13.01
36.92
70.32
----11.60
21.10
42.19
7.03
7.03
4.57
21.10
5.62
35.86
58.02
77.35
5.62
35.86
58.02
70.32
5.62
35.86
58.02
70.32
5.62
21.10
42.10
5.62
7.03
4.57
21.10
----15.82
31.29
4X6
4X6
4X6
DXA
4X6
4X6
4X6
4X6
4X6
4X6
4X6
4X6
6X8
6X8
6X8
6X8
6X8
8 X 10
8 X 10
----15.82
31.29
47.12
----15.82
15.82
47.12
----11.60
31.30
------------15.82
Size
For Higher
Pressure
Upto
1000 F
(538 C)
Flange
Rating
1.5 X 2
1.5 X 2
1.5 X 3
1.5 X 3
1.5 X 3
1.5 X 3
2X3
2X3
-----
DXB
EXB
FXB
DXB
EXB
FXB
EXB
FXB
-----
156.12
260.55
421.94
156.12
260.55
351.62
260.55
260.55
-----
129.75
216.61
361.11
129.75
216.61
351.62
216.61
260.55
-----
107.24
178.62
297.46
107.24
178.62
297.46
178.62
241.21
-----
47.12
78.41
130.82
47.12
78.41
130.82
78.41
130.80
-----
2X3
2X3
2X3
2X3
3X4
3X4
3X4
3X4
3X6
3X6
BXA
CXA
DXA
EXB
BXA
CXA
DXA
EXB
DXA
EXB
52.04
104.11
156.12
193.39
52.03
104.11
156.12
189.87
156.12
156.12
43.25
86.85
129.36
193.39
43.25
86.85
129.75
189.37
129.75
156.12
35.86
58.01
86.15
143.46
35.86
58.01
86.15
144.86
86.85
144.87
15.82
31.29
47.12
78.41
15.82
31.29
47.12
78.41
----78.41
4X6
4X6
4X6
4X6
BXA
CXA
DXA
EXA
52.04
70.32
105.48
-----
43.25
70.32
105.48
105.48
35.86
70.31
105.48
105.48
15.82
31.29
47.12
78.41
6 X 10
6 X 10
BXA
CXA
16.17
21.10
16.17
21.10
16.17
21.10
-----
100 F
450 F
800 F 1000 F
(37.8 C) (232.2 C) (426.7 C) (538 C)
Set press. Set press. Set press. Set press.
kg/cm2(g) kg/cm2(g) kg/cm2(g) kg/cm2(g)
NOTE
A --> ANSI 150#; B --> ANSI 300#; C --> ANSI 600#; D --> ANSI 900#; E --> ANSI 1500#; F --> ANSI 2500#.
7/06
Sizing
where,
A = Calculated throat/flow area, mm
= p d /4; d = Calculated throat/flow dia, mm
E = Required Relieving Capacity, kg/h
C = IBR constant
= 38 for FAINGER LESER make Safety Valves
P = Set Pressure, bar abs.
F = Superheat correction factor (F=1 for saturated steam)
2.7 Ts
1 + ---------- ,
1000
Ts is degree of superheat, C
NOTE
Using the above formula, the smallest flow Area A shall be calculated to discharge the required mass flow. The flow
area/dia selected shall be equal to or larger than the required one. Based on the selected flow area/dia, the inlet & outlet
size of the Safety Valve shall be chosen to match with the size as indicated in API 526 or as per customer requirement.
7/07
Sizing
Client : M/s.
1
Sl.No./TAG No.
Qty. (Nos.)
Size, In X Out, mm
Connections
M.O.C.
Body
Bonnet
Trim
Nozzle
10
Disc
11
Spring
12
Bellow Material
13
14
Sizing Code
15
16
Working Pressure
17
Design Pressure
18
19
Overpressure %
20
Fluid (Service)
21
Fluid State
22
23
Discharge Temp.oC
24
25
26
Cp/CV, if Gas/Vap
27
28
29
30
Orifice Letter
31
32
Model No.
33
Valve Type
34
Inspection by