INTRODUCTION
These notes accompany the release of OLGA 7.1.3 from SPT Group. The notes
describe changes in OLGA 7.1.3 and the previous releases relative to OLGA 7.1.0.
This document should be read by all users of the program. The complete program
documentation consists of the OLGA Help, Installation Guide and these Release
Notes. In addition, module specific User Guides are available.
The program is available on PCs with Microsoft Windows operating systems (Windows
XP, Windows Vista and Windows 7). Several versions of OLGA may be installed in
parallel.
The customer centre provides useful information about frequently asked questions and
known issues. The customer centre is accessible from www.sptgroup.com.
Please contact SPT Group if problems or missing functionality are encountered when
using OLGA or any of the related tools included in the OLGA software package.
E-mail: olgasupport@sptgroup.com
Telephone: +47 6389 0400
Fax: +47 6484 4500
Address: SPT Group AS, P.O. Box 113, N-2027 Kjeller, Norway
23 Jan 2012
Page 2
23 Jan 2012
Page 3
T
TIME, TSAT, TSV, TWATMFR, TWATMFRBOUN
V
VISHLEFF, VISRATIO, VISWTEFF, VOL, VOLCHANGE, VOLGBL
W
WACBEWA, WACWA, WALLROUGH, WATMFR, WATMFRBOUN, WAXPOROSITY,
WC , WCRIT and WCWALL.
This applies to all versions from OLGA 7.0. (OLGA-10923)
23 Jan 2012
Page 4
23 Jan 2012
Page 5
23 Jan 2012
Page 6
Parametric studies
Saving Parallel simulations
Parallel simulations could not be retrieved when you had saved a case and then tried
to reopen it.
This is fixed and the number of Parallel simulations is saved to the case.
(OLGA 10599)
Run parallel simulations in Parametric Study
You can now run more than 1 parallel simulation in parametric study with the Run
Study button in the Parametric study window. Due to an error this was not possible in
OLGA 7.1. Note that this functionality is not implemented if you run a parametric study
in batch.
(OLGA-10514)
23 Jan 2012
Page 7
Wells
Unit in Casing&Completion updated
The selected unit of top and bottom header columns of the casing completion table is
now updated correctly when the unit is changed.
(OLGA 10509)
Fixed error when changing the lumped reservoir depth to lower depths
In some circumstances, when you changed the depth of a lumped reservoir inflow, you
could get a warning that the Top MD could not be below the Bottom MD. This error only
appeared if you selected distributed inflow.
(OLGA 10627)
The smoothing factor w is an S-shaped smooth curve going from zero to one as liquid
volume fraction goes from 5.5% to 4.5%. The value of the smoothing factor w is 0.5
when the liquid volume fraction is 5%. The smoothing factor is continuous and has
continuous differential in the range it is used. The change will affect the inner wall
surface temperature (TWS) for high gas flow rate. In particular, you will not see
discontinuities (sudden drop) in TWS when liquid volume fraction drops below 5% for
high gas flow rates.
(OLGA 10406)