Sei sulla pagina 1di 24

( III ) INSULATING SYSTEM PAINTS

(A) WATER PROOFING


ROOF
SILICONE STONE GUARD
ACRYLIC LATEX CAULK
ACRYLIC LATEX CAULK SUPER SEAL
SWIMMING POOL

(B)THERMAL INSULATING PAINTS


INTUMESCENT PAINT
FIRE RETARDANT
FIRE RETARDANT CLEAR
FIRE RETARDANT THINNER
CAVALIER THERMAL INSULATING PAINT

(C) ANTI CARBONATION SYSTEM


PENETRATING SILOXANE PRIMER SEALER
AQUA SILOXANE PRIMER
ALIPHATIC ACRYLIC H.B.
PROTECT SEAL

(A) WATER PROOFING


ROOF
SILICONE STONE GUARD
ACRYLIC LATEX CAULK
ACRYLIC LATEX CAULK SUPER SEAL
SWIMMING POOL

ROOF
DESCRIPTION

RECOMMENDED USE

Colors
Finish
Viscosity
Specific Gravity
Solid by Weight %
Theoretical Spreading Rate
Film Thickness
Elongation - DIN 53455
Water Resistance
Water Vapour Permebility
U. V. Resistance
Reinforcement
Drying Time

Application Methods
Thinning / Cleaning of Tools

An Acrylic copolymer base, one component seamless, highly flexible


and durable waterproofing system which has good adhesion and
excellent weather resistance.
Roof protection, also suitable to protect expanded polyurethane foam
from deterioration by U.V rays.
TECHNICAL INFORMATION
White, Brick.
Smooth - Semi Gloss.
20 - 30 Poise.
1.34 0.05
60 2%
2 - 6 m/Lit. (depending on thickness).
(D.F.T.) 300 - 400 microns per coat.
(W.F.T.) 650 - 860 microns per coat.
400% Approx. (max).
Excellent
Good
Excellent
Fibre Glass
Touch dry : 4 - 6 hrs.
Recoatable: 12 - 16 hrs.
APPLICATION DATA
Brush, Roller or Towel.
Water.

RECOMMENDED SYSTEM
Primer Coat: 1 coat National Roof diluted (1 : 1) with water.
Intermediate coat: 1 coat National Roof diluted (2 : 1) with water.
Fix National Fiber Glass mesh while the intermediate is wet, allow to dry.
Top Coat: 1 - 2 coats National Roof undiluted.
OR
Without fibre mesh directly apply over dry intermediate coat 2 coats undiluted National Roof.
SURFACE PREPARATION
Must be clean, dry and free from dust, sand, other contaminations. Local touch -up of larger blow holes /
cracks should be carried out prior to the application of the first full coat of National Roof.

1/2

ROOF
MISCELLANEOUS DATA
STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

The product must be stored according to National Regulations. The


product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.
2/2

SILICONE STONE GUARD


DESCRIPTION

RECOMMENDED USE

A Silicone base transparent water proofing system which has good


penetration and drying even on damp substrate and develops water
repellency very fast along with high alkaline resistance.
All kind of concrete, mineral stucco, cement fiber-boards, sand-line brick
work, mineral paints etc

Flash Point

TECHNICAL INFORMATION
Clear, Transparent.
Matt.
2.5 - 3.5 Poise.
0.78 0.02
5 0.2%
3 - 5 m/Lit.
Touch dry : 1 hr.
Recoatable: 2 - 4 hrs.
38C

Application Methods
Thinning / Cleaning of Tools

APPLICATION DATA
Brush, Roller or Spray.
White Spirits.

Colors
Finish
Viscosity
Specific Gravity
Solid by Weight %
Theoretical Spreading Rate
Drying time

SURFACE PREPARATION
The stone walls should be throughly clean from dust and dirt.
MECHANICIAL
Reacts with atmospheric moisture or pore water in the substrate, thereby generating the active ingredient and
liberating alcohol, the active ingredient greatly lowers absorbency of the substrate. Since neither pores nor
capillaries are clogged, the substrate retains a very high degree of water vapor permeability.

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
6 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

ACRYLIC LATEX CAULK


DESCRIPTION

RECOMMENDED USE

An Acrylic copolymer base sealant filler which is flexible, has high


adhesion and good weather resistance along with resistance to
algae/moss/fungus.
For filling up splits and parties in door and windows as well as sanitary
pipes.

Colors
Viscosity
Specific Gravity
Solid by Weight %
Drying Time

TECHNICAL INFORMATION
White, Bronze.
Thick paste.
1.56 0.05
75 2%
Touch dry: 30 min.
Hard dry : 24 hrs.

NOTE:

It must not be used for splits wider than 1cm before treatment.

Application Methods
Cleaning of Tools

APPLICATION DATA
Special Gun.
Water

SURFACE PREPARATION
Surface to be sealed should be sound dry, free of oils, dust mortar spatter, release agents, old caulks,
intermediate old paint or other contaminants.

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

ACRYLIC LATEX CAULK SUPER SEAL


DESCRIPTION

RECOMMENDED USE

A high solid Styrene-Acrylic base sealant filler which is flexible, has


high adhesion and good weather resistance along with resistance to
algae/moss/fungus.
For filling up splits and parties in door and windows as well as sanitary
pipes.

Colors
Specific Gravity
Solid by Weight %
Drying Time

TECHNICAL INFORMATION
White
1.68 2%
70 2%
Touch dry : 2 hrs.
Recoatable: 6 hrs.

NOTE:

It must not be used for splits wider than 1 cm before treatment.

Application Methods
Cleaning of Tools

APPLICATION DATA
Special Gun.
Water

SURFACE PREPARATION
Surface to be sealed should be sound dry, free of oils, dust mortar spatter, release agents, old caulk,
intermediate old paint or other contaminants.

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

SWIMMING POOL
DESCRIPTION

A chlorinated rubber base paint having good color retention, high


resistance to severe weather conditions, durability and flexibility.

RECOMMENDED USE

For use on concrete, swimming pool etc.

Flash point

TECHNICAL INFORMATION
White, Blue.
Smooth & Matt.
14 - 16 Poise.
1.44 0.05
70 5%
5 - 6 m2/Lit.
Touch dry: 15 - 20 min.
Hard dry : 2 - 4 hrs.
35C

NOTE:

It must not be used for splits wider than 1 cm before treatment.

Application Methods
Thinning / Cleaning of Tools
Film Thickness
Guiding Data for Airless Spray

APPLICATION DATA
Brush, Spray, Roller.
Ready for use, could be diluted with Synthetic Thinner.
(D.F.T.) 100 microns.
Nozzle Tip: 0.015" - 0.20"
Nozzle Pressure: 2200 P.S.I

Colures
Finish
Viscosity (25C)
Specific Gravity
Solid by Weight %
Theoretical Spreading Rate
Drying time

SURFACE PREPARATION
Surface must be clean, dry and free from oil grease, dirt etc...

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 month.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

(B)THERMAL INSULATING PAINTS


INTUMESCENT PAINT
FIRE RETARDANT PAINT
FIRE RETARDANT CLEAR
FIRE RETARDANT THINNER
CAVALIER THERMAL INSULATING PAINT

INTUMESCENT PAINT
DESCRIPTION

A special resin base intumescent paint developed for protection from


fire. The dried film gives resistance against fire and protection to base
substrate.

RECOMMENDED USE

As an intumescent top coat paint on wood, steel, concrete etc.

Colors
Finish
Solid by Volume %
Theoretical Spreading Rate
Specific Gravity
Drying Time

Fire Resistance
Flash Point

Application Methods
Thinning (Max. Vol.)
Film Thickness
Guiding Data for Airless Spray

TECHNICAL INFORMATION
White
Matt or Silky
60 2%
3 m2/Lit. per coat.
1.20 0.05
Touch Dry: 2 hrs.
Recoat Interval: 24 hrs.
Hard Dry: 48 hrs.
Temperature, humidity, air movment, film thickness and number of coats
all affect the drying time.
Direct : 600C: 30 min.
Indirect : 600C: 2 hrs.
29C
APPLICATION DATA
Brush, Roller or Spray.
5 - 10% by National Thinner No.110
(D.F.T.) 200 microns.
(W.F.T.) 380 microns.
Nozzle Orifice: 0.0017"
Nozzle Pressure: 2200 P.S.I.
Atomizing Pressure: 50 P.S.I.

SURFACE PREPARATION
Surface should be thoroughly cleaned, dry and primed.
1)
Apply first thin coat.
2)
Apply second coat.
3)
Apply third coat for better fire retardant properties.

1/2

INTUMESCENT PAINT
MISCELLANEOUS DATA
STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

The product must be stored according to National Regulations. The


product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.
2/2

FIRE RETARDANT PAINT


DESCRIPTION

A solvent special resin base fire-retardant coating developed for giving


protection against fire. When applied on a surface gives fire resistance
and protects the base surface.

RECOMMENDED USE

As a fire retardant topcoat on wood, steel, concrete, etc.

Colors
Finish
Solid by Volume %
Theoretical Spreading Rate
Specific Gravity
Drying Time:

Fire Resistance
Flash Point

Application Methods
Thinning (Max. Vol.)
Film Thickness
Guiding Data for Airless Spray

TECHNICAL INFORMATION
White
Matt
55% 2
2.5 m2/Lit.
1.25 0.05
Touch Dry: 1 - 2 hrs.
Recoat Interval: 10 - 12 hrs.
Hard Dry: 24 hrs.
Temperature, humidity, air movment, film thickness and number of coats
all affect the drying time.
Direct : 400C : 30 min.
Indirect : 400C : 2 hrs.
29C
APPLICATION DATA
Brush, Roller or Spray.
5 - 10% by National Fire Retardant Thinner.
(D.F.T.) 100 microns.
(W.F.T.) 180 microns.
Nozzle Orifice: 0.0017"
Nozzle Pressure: 2200 P.S.I.
Atomizing Pressure: 50 P.S.I.

SURFACE PREPARATION
Surface should be thoroughly cleaned, dry.
1)
Apply first thin coat.
2)
Apply second coat.
3)
Apply third coat for better fire retardant properties.

1/2

FIRE RETARDANT PAINT


MISCELLANEOUS DATA
STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

The product must be stored according to National Regulations. The


product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.
2/2

FIRE RETARDANT CLEAR


DESCRIPTION

RECOMMENDED USE

Colors
Finish
Solid by Volume %
Theoretical Spreading Rate
Specific Gravity
Drying Time

Fire Resistance
Flash Point

A solvent synthetic resin base Fire Retardant Clear specially developed


to give a clear transparent finish which when applied protects the surface
from fire.
Suitable for use on wood and other surfaces making it fire retardant by
resisting the fire for a prolonged period.
TECHNICAL INFORMATION
Clear, Transparent.
Semigloss.
37 % 2
4 m2/Lit.
0.94 0.05
Touch Dry: 1 - 2 hrs.
Recoat Interval: 10 - 12 hrs.
Hard Dry: 24 hrs.
Temperature, humidity.air movment, film thickness and number of coats
will all affect the drying time.
Direct : 600C: 30 min.
Indirect : 600C: 1 hrs.
32C
APPLICATION DATA

Application Methods
Thinning (Max. Vol.)
Film Thickness
Guiding Data for Airless Spray

Brush, Roller or Spray.


5 - 10% by National Thinner No.110.
(D.F.T.) 100 microns.
(W.F.T.) 270 microns.
Nozzle Orifice: 0.0017"
Nozzle Pressure: 2200 P.S.I.

SURFACE PREPARATION
Surface should be thoroughly cleaned, dry.
(1) Apply first thin coat National Fire Retardant Paint
: 2 - 3 coats
(2) Apply second coat National Fire Retardant Clear
: 1 coat
OR
(3) Apply National Fire Retardant Clear
: 3 coats

1/2

FIRE RETARDANT CLEAR


MISCELLANEOUS DATA
STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

The product must be stored according to National Regulations. The


product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.
2/2

FIRE RETARDANT THINNER


DESCRIPTION

A special Thinner for Fire Retardant Coating.

RECOMMENDED USE

As reducer Thinner for Fire Retardant Coating.


TECHNICAL INFORMATION

Appearance

Transparent Liquid.

Specific Gravity @ 15 C

0.77 - 0.79

Viscosity by Fordcup B4

12 - 14 Seconds.

Odour

Mild

Flash Point

41C

Refractive Index @ 20C


ASTM D-1218

1.432

Distillation Range @ 101,3kpa


(ASTM D-1078)

150 - 197C

STORAGE

HANDLING
SHELF LIFE

SAFETY / HEALTH

NOTE:

MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
24 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

CAVALIER THERMAL INSULATING PAINT


DESCRIPTION

RECOMMENDED USE

An Insulating paint based on water base elastomeric Acrylic resin. It


contains special hollow ceramic microspheres as primary filler, which
mainly functions for thermal insulation. The dried film has good
flexibility, adhesion, toughness and excellent water resistance and UV
resistance. It contains antifungal and antibacterial additives.
Most suitable as roof coating, as water proofing and thermal insulating
material. Can be applied on cementitious surfaces, metal roofs for
commercial and residential buildings. Also useful for duct coating
insulation.

Flash Point

TECHNICAL INFORMATION
White and Light colors.
Matt / Rough
56% 2%
1.0 - 0.6 m2/Lit. (depending on thickness).
1.05 0.05
Touch Dry: 4 - 6 hrs.
Recoat Interval: 12 - 16 hrs.
Temperature, humidity, air movement, film thickness and number of
coats all affect the drying time.
Water base.

Application Methods
Thinning (Max. Vol.)
Thinning / Cleaning of Tools
Film Thickness

APPLICATION DATA
Roller, Spray, long haired brush or knife applicator.
5% depending on the method of application.
Water
(D.F.T.) 600 -1000 microns.

Colors
Finish
Solid by Volume %
Theoretical Spreading Rate
Specific Gravity KG/L
Drying Time

SURFACE PREPARATION
Surface should be thoroughly cleaned, dry and applied as follows:-.
National Acrylic Primer (W.B.)
: 1 coat
OR
National Thermal Insulating Paint (1:1 diluted)
: 1 coat
: 2 coats
National Thermal Insulating Paint
For galvanized surface use National Wash Primer before application.

1/2

CAVALIER THERMAL INSULATING PAINT


MISCELLANEOUS DATA
STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

The product must be stored according to National Regulations. The


product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.
2/2

(C) ANTI CARBONATION SYSTEM


PENETRATING SILOXANE PRIMER SEALER
AQUA SILOXANE PRIMER
ALIPHATIC ACRYLIC H.B.
PROTECT SEAL

PENETRATING SILOXANE PRIMER SEALER


DESCRIPTION

RECOMMENDED USE

Colors
Finish
Viscosity
Specific Gravity KG/L
Solid by Weight %
Penetration)
Drying Time

Flash point
Application Methods
Thinning (Max. Vol.)
Thinning / Cleaning of Tools
Guiding Data for Airless Spray
Conv. Spray Requirements
Recommended System

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

A special solvent based polysiloxane primer sealer, with excellent


penetrating and good sealing properties. It penetrates deeply into the
pores of the cement concrete and masonry surface, resulting better
water repellant properties. It has excellent resistance to alkali, moisture
and light.
As Penetrating Primer Sealer for interior and exterior concrete, plaster
asbestos, brick work, etc
TECHNICAL INFORMATION
Clear
Smooth, Matt.
20 2%
0.91 0.02
4 - 5 m2/Lit. (Depends on surface and film thickness).
2 - 3 mm.
Touch Dry : 1 hrs.
Recoatable: 2 - 3 hrs.
Temperature, humidity, air movement and film thickness all affect the
drying time.
25C.
APPLICATION DATA
Brush, roller or spray.
Ready to use.
National GP Thinner.
Nozzle Tip: 0.025"
Nozzle Pressure As low as possible.
As low as possible.
Apply one coat of National Penetrating Siloxane Sealer for masonry
on dry and clean surface. On too much porous surface apply two coats.
Then apply recommended system.
MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected
from heat and direct sunlight at temp 5-35C. Containers must be kept
tightly closed.
Handle with care, mix well before use.
6 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

AQUA SILOXANE PRIMER


DESCRIPTION

RECOMMENDED USE

Colors
Finish
Viscosity
Specific Gravity KG/L
Solid by Weight %
Penetration)
Drying Time

Flash point
Application Methods
Thinning (Max. Vol.)
Thinning / Cleaning of Tools
Guiding Data for Airless Spray
Conv. Spray Requirements
Recommended System

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

A special solvent based polysiloxane primer sealer, with excellent


penetrating and good sealing properties. It penetrates deeply into the
pores of the cement concrete and masonry surface, resulting better water
repellant properties. It has excellent resistance to alkali, moisture and
light. It contains antifungal and antibacterial properties.
As Penetrating Primer Sealer for interior and exterior concrete, plaster
asbestos, brick work, etc
TECHNICAL INFORMATION
Clear
Smooth, Matt.
16 2%
1.00 0.05
4 - 5 m2/Lit. (Depends on surface and film thickness).
2 - 3 mm.
Touch Dry : 1 hrs.
Recoatable: 2 - 3 hrs.
Temperature, humidity, air movement and film thickness all affect the
drying time.
Water base.
APPLICATION DATA
Brush, roller or spray.
Ready to use.
Ready to use, if required water to be used.
Nozzle Tip: 0.025"
Nozzle Pressure As low as possible.
As low as possible
Apply one coat of National Aqua Siloxane Primer for masonry on dry
and clean surface. On too much porous surface apply two coats. Then
apply recommended system.
MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
12 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

ALIPHATIC ACRYLIC H.B.


DESCRIPTION

RECOMMENDED USE

Colors
Finish
Volume Solids
Specific Gravity KG/L
Theoretical Spreading Rate
Film Thickness
Drying Time @ 30C.

It is special Aliphatic Acrylic H.B. based on methacrylate polymer. Has


tough dry film giving long lasting performance, very good adhesion and
weather resistance. Additionally it has excellent resistance against water
and U.V. radiation and anti-carbonization properties.
Specifically developed as a top coat on National Penetrating Siloxane
Primer Sealer, for application on cementatious surface, walls, etc.
TECHNICAL INFORMATION
As per shade card.
Matt.
55 2%
1.40 0.05 (for white and pastel shades).
7 - 8 m2/Lit. per coat
(D.F.T.) 70 microns per coat (Depends on surface).
(W.F.T.) 130 microns per coat (Depends on surface).
Touch Dry: 1 hr.
Recoatable: 3 - 4 hrs.

Hard Dry : 24 hrs.


Flash point
Application Methods
Thinning (Max. Vol.)
Thinning / Cleaning of Tools
Guiding Data for Airless Spray
Conv. Spray Requirements
Mixing Ration (Volume)
Pot Life @ 30C.
Recommended System

STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

Temperature, humidity, air movement and film thickness all affect the
drying time.
32C.
APPLICATION DATA
Roller or spray.
5% depending on the method of application.
National Acrylic Thinner.
Nozzle Tip: : 0.018" - 0.020"
Nozzle Pressure: 2100 P.S.I.
Automizing Pressure: 50 P.S.I.
Base : Hardener : N.A.
N.A.
National Penetrating Siloxane Primer Sealer: 1 coat.
National Aliphatic Acrylic H.B.
: 2 coats.
MISCELLANEOUS DATA
The product must be stored according to National Regulations. The
product should be kept in cool and well ventilated place, protected from
heat and direct sunlight at temp 5-35C. Containers must be kept tightly
closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.

PROTECT SEAL
DESCRIPTION

RECOMMENDED USE

National Protect Seal has been specifically designed to meet the


requirements of durable, protective, water proofing membrane for
concrete surfaces. It is based on Acrylic emulsion, with inert pigment
and has good flexibility, abrasion and elastomeric properties. It
contains anti-fungal and anti-bacterial additives.
Good mechanical and abrasion resistant properties, mostly suitable for
curb stone, bridges, car parking areas, since it has excellent anticarbonation, chloride ion stability, chemical resistance, suitable for
concrete surfaces.
TECHNICAL INFORMATION

Colors
Finish
Volume Solids
Specific Gravity KG/L
Theoretical Spreading Rate
Film Thickness
Drying Time @ 30C.

Flash point

White and pastel colors.


Satin.
57 2%
1.30 0.05
6 m2/Lit. per coat.
(D.F.T.) 100 microns per coat (Depends on surface).
(W.F.T.) 175 microns per coat (Depends on surface).
Touch Dry: 30 min.
Recoatable: 8 - 10 hrs.
Temperature, humidity, air movement and film thickness all affect the
drying time.
Water base.
APPLICATION DATA

Application Methods
Thinning (Max. Vol.)
Thinning / Cleaning of Tools
Guiding Data for Airless Spray
Conv. Spray Requirements
Mixing Ration (Volume)
Pot Life @ 30C.
Recommended System

For metal, use suitable primer

Brush, roller or spray.


5% depending on the method of application.
Water.
Nozzle Tip: : 0.017" - 0.020"
Nozzle Pressure: 2200 P.S.I.
Automizing Pressure: 30 - 40 P.S.I.
Base : Hardener : N.A.
N.A.
National Acrylic Primer (W.B.) : 1 coat
National Protect Seal
: 2 - 3 coats.

* Thick material can be applied by trowel, without dilution.

1/2

PROTECT SEAL
MISCELLANEOUS DATA
STORAGE

HANDLING
SHELF LIFE
SAFETY / HEALTH

NOTE:

The product must be stored according to National Regulations. The


product should be kept in cool and well ventilated place, protected
from heat and direct sunlight at temp 5-35C. Containers must be kept
tightly closed.
Handle with care, mix well before use.
18 months.
- Ensure good ventilation during application and drying.
- Avoid contact with skin and eyes. While painting it is advisable to
wear eye protector. In case of contact with eyes, rinse immediately
with plenty of water and seek medical advice. To remove splashes
from skin; use soap and water or a recognized skin cleaner.
- Keep out of reach of children.

We warranty the quality of our product and this data sheet represents test results and practical experience
obtained under controlled conditions. We reserve the right to change data without prior notice.
2/2