Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
The 2210 and 2213 control units are designed to work with the 2223 oxygen transmitter. The
graphical user interface allows for simple operation and has multi-language capability as
standard.
Controls up to six Transmitters simultaneously
Certified for hazardous areas, flammable dusts and flammable gases
Explosion proof design means no instrument purge required
Simple two wire digital connection for ease of installation
Digital Communications Enabled as Standard
Hazardous Area Approvals:
ATEX Category 2 and ATEX Category 3
FM Class I, Division 1 and FM Class I, Division 2
CSA Class I, Division 1 and CSA Class I, Division 2
TIIS Zone 1
IECEx Zone 1 and Zone 2
The control unit provides full access to set up functions such as, auto-calibration, alarms,
relays and faults. A full set of diagnostics information is available that can be used to assist
with predictive maintenance. The unit is compliant with the requirements of NAMUR.
SPECIFICATIONS
Power Supply:
PERFORMANCE
See the relevant Transmitter Technical Data Sheet for
the performance specification
Output resolution:
display
0.001% oxygen
PHYSICAL
IP Rating:
Mounting:
AMBIENT CONDITIONS
Temperature:
Operating:-10 to 50C (14F to 122F) in
sheltered location
Storage: -20 to 70C (-4F to 158F)
Atmospheric Pressure:
76 to 112 kPaa (11 to 16.2 psia)
Warm up time:
Useable immediately, but typically 2 hours
from cold start at 20C
Autocalibration initiation
Remote range change
Validity of mA inputs
Digital flow sensors
Relative Humidity:
0-95% non-condensing
FEATURES
STANDARD:
Graphics LCD display with LED backlight and integral
keypad (seven button). The analyser comes with
password protection as standard.
Software has multi-language capability (English,
French and German languages)
The ability to connect up to six transmitters to a single
control unit.
The maximum separation between a single transmitter
and control unit is 1000m. Please consult Servomex
for the maximum separation between multiple
transmitters and a single control unit.
Digital Communications enabled with Modbus
protocol as standard.
Auto-calibration software as standard (operation will
need one of the relay option cards).
OPTIONAL:
Four option slots exist, any of the following may be
fitted in to each slot:
mA Output Board:
Relay Board:
EC DIRECTIVE COMPLIANCE
The 2210 and 2213 Control Units comply with the
Low Voltage Directive 73/23/EEC and the EMC
Directive 89/336/EEC (as amended by Directive
92/31/EEC), both as amended by Directive 93/68/EEC.
They conform to the following harmonised
European standards for product safety and
electromagnetic compatibility:
EN 61010-1: Safety requirements for electrical
equipment for measurement, control and laboratory
use.
EN 61326-1: Electrical equipment for
measurement, control and laboratory use - EMC
requirements (All induced errors are less than the
intrinsic error).
This product is rated for Installation Category II
in accordance with IEC 664.
This product is rated for Pollution Degree 2 in
accordance with IEC 664.
ATEX (Europe)
ATEX (Europe)
FM (USA)
FM Zones (USA)
CSA (Canada)
CSA Zones
(Canada)
IECEx (other)
Weight:
Ex II 3GD
EEx nC(ia) IIC T4
(-20C < Ta <50C)
Class I, II & III, Division 2
Groups A,B,C,D,F,G
T4, Ambient temperature 50C max.
Class I, Zone 2 IIC T4
Ambient temperature 50C max.
Class I, Division 2, Groups A,B,C
and D
Class II, Division 2, Groups E,F
and G
Class III
Type 4X. T4. ambient temperature
50C maximum
Class I, Zone 2 approval, IIC T4
(Ta = 50C) with IS outputs
Ex nCL ia IIC T4 (-20C Ta +50C)
DIP A21 TA 70C
10kg (22lbs)
FM (USA)
FM Zones (USA)
CSA (Canada)
CSA Zones
(Canada)
TIIS (Japan)
IECEx (other)
Weight:
Ex II 2GD
EEx ia d IIC T4
(-20C < Ta <50C)
Class I, II & III, Division 1
Groups B,C,D,E,F,G
T4, Ambient temperature 50C max.
Class I, Zone 1
AEx d ia (ia IIC) IIB + H2 T4
Ambient temperature 50C max.
Class I, Division 1,Groups B,C and D
Class II, Division 1,Groups E,F and G
Class III
Type 4X, T4, ambient temperature
50C maximum
Class I, Zone 1 approval, Ex d ia (ia)
IIB + H2, T4 (Ta = 50C)
Ex ia d IIC T4
Ex d ia IIC T4 (-20C Ta +50C)
DIP A21 TA 70C
25kg (55lbs)
11
236
290
178
266
12
51
11
478
280
478
280
490
315
250
275
230
290
www.servomex.com
SERVOMEX COMPANIES, AGENTS AND REPRESENTATIVES ARE LOCATED THROUGHOUT THE WORLD. YOUR NEAREST CONTACT IS:
Certificate No._________Q05166
BS EN ISO 9001
Servomex Group Limited, Jarvis Brook, Crowborough, East Sussex, TN6 3DU, England
Servomex B.V., Stephensonstraat 20, 2723 RN Zoetermeer, Netherlands
Servomex S.A., 8 Rue Proudhon, B.P. 50, 93212 St Denis La Plaine Cedex, France
Servomex GmbH, Mnsterstrae 5, 59065 Hamm, Germany
Servomex Company Inc., 525 Julie Rivers, Suite 185, Sugar Land, Texas 77478-2847, USA.
Servomex Asia Pacific Ltd, 7F, No.88, Sec. 6, Chung Shan N. Rd., Taipei, Taiwan
Servomex Group Limited., SAIF Zone, Executive Suites Z1-56, PO Box 8962, Sharjah, UAE.
Servomex Asia Pacific Ltd, (Spectris Instrumentation and Systems (Shanghai) Ltd)
Building 9, Shanghai Euromate Industrial Park, No.88 Lane 2888 Hua Ning Road, Xingzhuang Industrial Park, Shanghai 201108 PR China
Servomex Japan, Spectris Co.Ltd., 1F JP Kaji-cho Bldg., 3-5-2 Kandakaji-cho, Chiyoda-ku,Tokyo 101-0045, Japan