Exception Code= 171:


- cause code 14 : this is reflected by pmNoRrcReqDeniedAdmUlHw, this
cause code means that more RAX boards need to be added to the RBSs in
order to meet the uplink requirements. many admission rejects due to a
lack of uplink channel elements which will trigger soft congestion.
- cause code 15 : RbsDlHwResources this can be seen by
pmNoRrcReqDeniedAdmDlHw, this exception means that more Tx boards need to
be added in order to meet the downlink requirement for channel elements.
- cause code 16 : PhysHsChanLimit. maxNumHsdpaUsers 4 is surpassed
(license allows maximum of 4). example more then 4 HS users were trying
to make calls, but license only allows 4 HSDPA users. The solution is to
load a license allowing more HS users and to change parameter
maxNumHsdpaUsers to reflect the new license. .
- cause code 19 (similar to 17-20): SF16UL limitation --->This number
needs to be increased in order to avoid this accessibility restriction
for SH16UL which corresponds for example to RAB HS/64. example SF16UL set
to 16 meaning that the utrancell will only allow 16 radiolinks with
spreading factor 16. The analysis shows that this number has to be
increased in order to meet the traffic requirement.
- cause code 22 : EdchLimitServingCell, maxNumEulUsers = 4, license
allows 16, thus number of eul users for this cell should be increased to
allow for eul users.
-cause code 5 : DlCode. This can be seen by counter
pmNoRrcReqDeniedAdmDlChnlCode. This exception occurs when there is a
shortage of channelization codes. RRC is rejected because all the codes
are used up. A solution to this problem is to either deploy another
carrier or another RBS in order to offload the traffic
- cause code 25: The number of HS users with 2ms TTI within serving cell
is limited by parameter UtranCell::eulServingCellUsersAdmTti2 (default is
4). When more than eulServingCellUsersAdmTti2 UEs attempt to have
particular cell as serving cell with 2ms TTI, the exception coed is
raised. This may be applicable when changing serving cell, or RAB
establishment. It's most probbable, that higher number of this exception
codes comes directly from increased PS HS/EUL traffic.
Exception Code 7:
- causecode = 301 means drhDcRh_noResources. DC overloaded, not evenly
allocated, check "stda" command UEs column
Exception Code 11:
- causecode = 8: CELLO_AAL2NCI_SERVER_OVERLOAD. This reject cause is
issued to protect aal2 server because of a possible overload from the
application side. Some of the reasons that cause those rejects: reason 1,

the AAL2NCI client is sending bursts of connection establishment requests


to the server. The server accepts a limited number (500) of requests (for
all clients together), and it will reject all further rejects before it
finishes handling at least 10 of them. reason 2, some of the data
transfer resources (AAL2RI clients) are not responding fast enough or not
responding at all on connect/disconnect requests received from the AAL2RI
server (the same program as AAL2 NCI server) thereby delaying the moment
when the server will be able to accept new connection establishment
requests.
- causecode = 411: Problem seen in DRH allocating traffic beared in the
internal CPP AAL2 reservation function. Even in IP configuration 3820
still uses ATM for internal communication.
- causecode = 406: drhTrBr_cppNciNodeConnRej ( NCI rejected the local
AAL2 connection request. It could be connetion between DC SP and ET
board.
- causecode 67108962: This cause indicates that there are currently no
AAL2AP program that could serve current CelloAal2Nci_netConnectReq(). The
AAL2AP program is handling the signalling to the peer node. There are two
possible reasons for this. reason 1 the AAL2AP program is temporarilly
down due to a (re)start. reason 2 the rpuId specified for the Aal2Ap
object is not running in active mode
- causecode = 83886257: AAL2 Congestion. Solution 1: Add three aal2paths
(QOS CLASS A,B,C) in congestion Iublink. Impact Small. Only add some new
MOs, no modify or delete Solution 2: Increase egressAtmPcr in
AtmTrafficDescriptor. Impact Medium. SW Configuration Change. Some MOs
have to be changed Solution
Exception Code 11: Change the Iub over ATM to IP Transport. Impact Large.
Both SW and HW Configuration change
- causecode = 83886258 and causecode = 405: the reason is that current
connection requires a bandwidth greater than the bandwidth available on
any of the paths towards that node. The congestion will remain until at
least one connection towards that node has been released:
Exception Code 12: Received signal faultyTrBrInd. IUC Initialisation
procedure wasnt completed successfully. Either the Initialisation Frames
werent sent from the MSC or were lost in the Transport Network. lock each
Aal2path towards MSC individually.
Exception Code 23:
- Cause code 334: Cause 1 CNID modification on the RNC. the URA to FACH
succ rate will drop to 0% temporarily. Cause 2 Capacity crossed on all
PDR devices which can be checked via coli command: lh mod drh_pdrrh.
Cause 3. PDR load spike reported to DRH. SP sends load status in
pdrLoadStatusInd and it can be Low, Medium or High. When High load is
reported by sp, status flag is set to LoadHigh and sp becomes unavailable
for Rab resuming.
Exception Code 40:
- causecode = 0: DC devices lost and DcRh can't use them. In DcRh there
is a fault protection mechanism to removes the devices that are not

attached within 20 seconds. This mechanism prevents hangings. See


SCS1094225
Exception Code 54: This exception is generated when maximum number of
retransmissions are performed on RLC and reset
- causecode = 1: seen in conjunction the exceptions EC521/523/552. In
many cases an RLC reset has occurred due to max number of RLC
retransmissions being sent.
- causecode = 101: seen with problems with primary scrambling codes or
other misconfiguration in cells.
rBId 16 or 17, Processing failure on PS rbId = 16, release PS Rab(s)
involving UeRc=54, sourceConnType = uehPsInt64HsPsInt64Hs. This is raised
when the UE initiates an RLC reset due to the mis-match in PDU size
Exception Code 58:
- causecode=1, CELL_NOT_IN_NEIGHBOURSET, means that a proposed cell to be
added to an Active Set is not part of the neighbour list. Generally this
means checking that neighbour lists are correct and reconfiguring as
needed. This may be a symptom of an issue reported in PLM Info 717 which
can affect this RNCs SW Release, W10.1.3.3.
Exception Code 110: Received signal messageReject on UehNbapDedicatedP.
- cause code 1: Encode failed, cause code 2: Timeout, cause code 3:
Transaction removed. Either network overload or link disturbances.
Investigate loss of RadioLinkSetupRequestFDD or RadioLinkReconfPrepare
messages between the SRNC and RBS, or response messages not being sent
back by the RBS
Exception Code 122: incorrectly stored conn id is being used by a drift
context. In this case when RabEstablishDedToCom is deported an SCCP
disconnect is sent towards the SRNC, generating the exception in the
SRNC
Exception Code 130: Incorrectly stored conn id is being used by another
serving context which has a drift RL set up. In this case when
RabEstablishDedToCom is deported and SCCP disconnect is sent towards the
DRNC, generating the exception in the DRNC
Exception Code 142: When an IU signalling connection is being set up for
a UE Connection, the signal uehRanapInitialUeReq is sent from UEH via RNH
to the CN. In response to this request a uehRanapInitialUeRej could be
returned by RNH to indicate that the connection setup failed. If
uehRanapInitialUeRej is received in the SignConnSetup procedure with
"disconnectType = abnormaldisconnect" then UEH Exception 142 is raised.
Exception Code 160: RRC Request failures caused by too high ModMP CPU
load. The ModMP start rejecting RRC Request when the CPU load reaches
85%. Verify with counter pmNoRejRrcConnMpLoadC
Exception Code 181: Received signal connRejV2 on
UehUeCtxtProcCpxAal2NciP. Enter the rejectType = X & causeCode = XXXXXXX

in the form on the AAL2 troubleshooting web page to get decoded


information:
http://www.design.etk.extern.eu.ericsson.se/DEPARTMENTS/ETK_D_C/sys_mng/n
ch_i_v/aal2_hints.shtml
Exception Code 223: result of decreased available resources in the node.
Similar to 171
Exception Code 262: Failed to allocate a UeContext in UEH. Too many
Hanging Drift UE Ctxts. See Primus SCS921790
Exception Code 310: Received signal NBAP RADIO LINK SETUP FAILURE. Cause
code: 0, unknown_CID, 1 cell_not_available, 2 power_level_not_supported.
- cause nodeB-resource-unavaiable: The reason for this issue is RBS
running out of resource, especially when to allocate E-DBCH for AGCH.
This indicates that the issue for this EC310 is simply heavy traffic
load.
Exception Code 311: Received signal NBAP RADIO LINK ADDITION FAILURE.
Cause code: 0, unknown_CID, 1 cell_not_available, 2
power_level_not_supported.
Exception Code 312: NBAP RadiolinkReconfigurationFailure
- cause REQUESTED_CONFIGURATION_NOT_SUPPORTED: Missing information in
NBAP message RL Reconfiguration Prepare.
Exception Code 327: Received signal NBAP RADIO LINK FAILURE INDICATION.
If UehDriftUeCtxtC: This happens when the connid which was incorrectly
released is reselected for a new incoming SCCP connection. When this
happens UEH detects that there are two UeRef associated with same connid
the hanging Drift Context and new Drift Context allocated for the
incoming RL Setup Request. UEH then triggers a release of the hanging
Drift Context. It is also possible that the SCCP disconnect is received
during deletion of the last RL in the DRNC. In this case, the RL in the
drift RBS will have been released but the context will not since SRNC
cannot send SCCP disconnect to DRNC.
Exception Code 400: The UE rejects the radioBearerSetup sent by the RNC
with failure cause : Invalid Configuration. Check radioBearerSetup
messages fo abnormal fields sent by the RNC. seen with qualcomm chipset
MSM6275/MSM6280.
Exception Code 401: UE receives SECURITY MODE COMMAND message with
variable INCOMPATIBLE_SECURITY_RECONFIGURATION=true, UE shall send
SECURITY MODE FAILURE message to RNC. RNC issues exception 401. Normal
behavior
Exception Code 407: Received signal RRC CellUpdate with Failure Cause.
Cell Update fails, UE in FACH release call

Exception Code 451: Received signal RANAP Relocation Preparation Failure.


Problem with IRAT handover
Exception Code 456: Received signal RANAP Initial Ue Reject. Investigate
Transport and Core Networks
Exception Code 504: TIMER T_RABREL_1 has expired waiting for RRC Radio
Bearer Release Response. Possible reasons for that: reason 1) The PS RAB
has some problem, such as faulty TrBr was reported, then UEH will drop
the whole call, so the CS call drop rate has also been affected. reason
2)Its timeout when waiting for Radio Bearer Release Response from UE.
reason 3) whether the UE has received the release request message. the
request message may not reach UE OR UE received the message, but decoded
error or too high BLER, UE cant understand the message. OR UE decoded
the request normally and sent out the response correctly, but RNC lost
the message. After the timers time-out, the UE has been dropped.
Exception Code 509: This covers the scenario where the UE is in
compressed mode and a timer expires while the RNC is waiting for a
message from the UE. The RNC sends RRC PhysicalChannelReconfiguration to
order the Ue to the new configuration on the RL. Once this RRC message is
sent, a timer "tcpmPcr" (5 seconds) is started and the RNC waits for
PhysicalChannelReconfigurationComplete from the UE. If this is never
received the timer expires and UEH Exception above is triggered.
Exception Code 512: This Exception can be raised when there is a problem
trying to perform IRAT CC UTRAN to GSM.
Exception Code 521: "TIMER rrcSetuptimerId has expired; InterfaceTimout".
Occurs when Neither RRC Connection Setup Complete or NBAP Radio Link
Restore Indication received This Exception can be sometimes be associated
with Synchronization issues between RNC and RBS, but no NodeSynch alarms
were observed from the RNC. Further investigation of the sites affected
would be needed to clarify the exact cause of this Exception.
Exception Code 523: Exception if expires: Timeout waiting for Active Set
update complete. In the soft handover procedure, timeout waiting for ASU
complete message. If the RNC does not receive either ACTIVE SET UPDATE
COMPLETE or ACTIVE SET UPDATE FAILURE message before the timer
tRrcActiveSetUpdate is expired, the RNC considers the communication with
the UE to be lost. This results in the connection being released and a
RANAP Iu Release Request is sent. This is normal system behaviour. The
system does not maintain the UE connection when the timer expires, the
call is released. The occurrence of EC523 indicates the customer may have
coverage issues in their network and need to perform RF optimization.
There may also be missing neighbour relations or incorrectly configured
primary scrambling codes.
Exception Code 529 inactivityDchTimerId has expired. The inactivity timer
expires due to a lack of, for example, RANAP RAB Assignment Request
investigate MSC. RNC considers this type of release a normal release see pmNoNormalNasSignReleaseCs pegging and not
pmNormalSystemNasSignReleaseCs
Exception Code 545: Timeout RRC SecurityModeComplete not received

Exception Code 552: TIMER T_CH_SWITCH_1 has expired Here the UE has not
responded during a Channel Switching procedure. Further investigation
required on the cells affected. From the DCG it is interesting to note
that nearly all the channel switching transitions involved DCH -> FACH.
This could suggest that UE lost contact with the network initially
leading to channel switching due to UE Inactivity which then experienced
this timeout.
Exception Code 554: Internal timing issue in the RNC when executing
Channel Switch. This CFN handling applies at Radio Bearer Setup and at
Radio Link Reconfiguration. At synchronised reconfigurations the RNC
decides at which point in time the reconfiguration shall take place. This
point in time is called the activation time for the reconfiguration and
it is signalled to both the RBS and UE in order for them and for the RNC
to perform the reconfiguration at exactly the same time. The activation
time is given as a Connection Frame Number (CFN).
Exception Code 562: related to the releasing of SCCP connections
Exception Code 563 This exception is generated when all radio links in
the Active Set have lost synch, i.e. NBAP Radio Link Failure cause
synchronization failure is received for all RLs. The exception is
generated after 5s timeout. Often optimization issue. Example reasons: 1)
UE for some reason stopped sending DPCCH (turns of transmitter). For
example battery is empty/removed. 2) UE for some reason suddenly
disappears from the range of the RBS. The change in RF must be so sudden
that power control is unable to adapt the power levels. For example walks
around the corner of a building, jumps into a train/car/bus 3) UE/RBS
for some reason send/receive DPCCH with the wrong scrambling code or
DPCCH format. Mismatch in configuration between RBS and UE. 4) UE has
timed out on one of the RLC-bearers (max number of retransmissions
followed by RLC Resets). UE is then forced to turn off TX and return to
Idle. 5) Simply a UE crash or UE fault for unknown issues. Remember that
Utran (RBS & RNC) is usually unaware of internal problems in UE. In most
cases, an unexpected UE crash would be noticed by Utran as "loss-ofULsynch"- EC563. 6) If the UE is engaged in a multiRAB, then problems on
PS side (e.g. transport NW issues) can result in RLC problems and that UE
is forced to go to Idle.
Exception Code 564: Timeout: The RNC (more accurately the allocated DC
device) sends Initialisation message to the MGW to negotiate the codec
type, but no response is received. RNC initiates release procedure by
sending a RAB-AssignmentResponse ( cause:radioNetwork/iu-up-failure) to
the MSC.
Exception Code 594: Received signal initialUeIdCollisionActionReq
This exception is commonly called UE Id Collision and can occur for
scenarios involving both speech and PS/HS. A UE Id collision EC594 is
triggered when the RNC detects a new RRC connection for a UE that the RNC
already has an existing RRC connection for. The race condition is that
the UE has lost connectivity with the network and tries to access again
with a new RRC connection request before the RNC has actually detected
and released the RRC connection for the loss of contact with the UE. In
this case, the exception code 594 is triggered as only one RRC connection
is possible. The delay in the RNC releasing the connection can be due to

loss of contact timers. The rcLost timer controls how long RNC waits
after losing a connection before releasing the resources. The purpose of
these timers is to reduce the number of dropped calls because the UE may
come back in synchronisation on the radio link before this timer expires
which will recover the call. This is just an example of where the network
is delaying releasing the RRC resources. The behaviour on the UE side can
be different between vendors resulting in UE retrying RRC connection
before RNC has released the previous RRC connection. Please refer to PLM
Info 562 for changes in behaviour of this Exception after P7.1.
Exception Code 595: UE doesnt reply to physical channel reconfiguration
complete message. Possible reason for that: a) UE doesnt support URA_PCH
state. b)Some problem with synch between network and UE, maybe poor RF
condition.
Exception Code 654: OGICAL ERROR IN NBAP RADIO LINK RECONF RESPONSE.
Decode and troubleshoot NBAP RadioLinkReconfigurationReady message, for
missing information.
Exception Code 702: LOGICAL ERROR IN RNSAP RADIO LINK ADDITION REQUEST.
RNC in DRNC role didn't understand the information from SRNC in
RadioLinkAdditionRequest message
Exception Code 756: logical error in rrc radio bearer reconf Message in
DL, so the UE thinks that the message is wrong
Exception Code 757: logical error in rrc radio bearer reconf complete
Message in UL, in this case is the RNC that does not like the answer from
the UE.
Exception Code 900: unallocated UeCtxt in UEH receives the unexpected
chSwitchEvalInd signal from DCS, this is caused by UE hanging /status
mismatch between UEH, DCS, DRH, And UEH will then send startSpAuditInd to
DCS to init audit between UEH/DCS/DRH, and finally all hanging UEs should
be released. It has nothing to do with the RRC rejection.
Exception Code 930: when the RNC rejects : 1. Cell Update with cause
uplinkDataTransmission when UE on Common Channel 2. Cell Update with
cause cellReselection when UE on URA_PCH

Exception Code 947: Failed handover of EUL/HS call and


release due to DCS set relOnReject = True. The reason for
failed handover is when there is only one cell in active set,
target cell not supporting HS or EUL.