C9600/C9800/ES3640 Error Codes


Rev.1 2005-5-24 Based on Status handler Rev.31

[Note]
The service calls that CU firmware displays on the operator panel (LCD) are color-coded in "S/C No." column as follows
(1) CU firmware or CPU detected a CU board related physical problem.
(2) CU firmware detected an anomaly in a program or data in nonvolatile media connected to CU board (ROM,FLASH memory,HDD) or in an optional board.
(3) CU firmware detected an anomaly in behavior in PU (including a violation of communication protocol between CU and PU). Where the cause exists (in CU or PU?) is not known.
(4) CU(CPU or CU firmware itself) detected an abnormal behavior of CU firmware. (It is possible that the root cause is a problem of the CU board.)
(5) PU firm detected a physical problem in mechanism or PU board and CU displays S/C No. according to the problem.
(6) Above (5) is happening and a user can fix the error.
When a S/C No. in red background column is reported, make sure you record the conditions when it happened (sent data, CU/PU firmware versions, operation and etc.) and also
print the MenuMap. The firmware problems in red column.
*1 S.C. = LCD displays a service call. P.O. = A message appears and prompts a user POW ON.
*2 When it happened, confirm it can be reproduced. After rebooting, operate the printer in the same way that caused the problem, and check if the same service call message appears.
*3 This service call may happen only at factory shipping.

Fatal No.

Name

001

Machine Check Exception

002

DSI Exception (Data read failure)

003
004
005

ISI Exception (Instruction read failure)


Alignment Exception (Memory access error)
Program Exception (Illegal instruction, trap
instruction, privilege violation, and so on)
Floating-point Unavailable Exception
Instruction Address Breakpoint Exception (for
debugging mode only)
Thermal Management Interrupt Exception
Instruction TLB miss <Reserved>
Data TLB load miss <Reserved>

006
007
008
009
010
011
012~019
020
021
022
023

Occurs under the following condition.


A serious problem in CU board was detected.
This is notified when CPU detected parity error of the address bug, the data bus or
the L2 bus; and so on
The program referred to an illegal address.
This is notified when CPU detected unexpected exceptions.

CU Font ROM Hash Check Error (resident)


<Reserved>
CU Font ROM Hash Check Error (ROM slot 1)

025

CU Font ROM Hash Check Error (ROM slot 2)

026

CU Font ROM Hash Check Error (ROM slot 3)


<Reserved>
027
CU Font ROM Hash Check Error (otherwise)
<Reserved>
028~029 <Not assigned>
030
CU RAM Check Error (resident)

Display *1

Leisus I/F

PX723

S.C.

Record the displayed information on LCD (max. 3 lines of hexdecimal numbers), and then reboot. *2

P.O.

P.O.
P.O.
P.O.
P.O.
P.O.

m
m

S.C.
P.O.
P.O.

m
-

The temperature of CPU exceeds 75C.

Reboot

The program referred to an illegal address.

Record the 24 digit addresses (usually 3) displayed in LCD, and


then reboot. *2

Data TLB store miss <Reserved>


<Reserved>
CU ROM Hash Check Error (resident or ROM slot A problem has happened to program ROM in CU.
CU ROM Hash Check Error (option 1)
CU ROM Hash Check Error (option 2)

024

How to handle
If rebooting the machine does not improve the symptom, you need
to replace the board.

P.O.

m
m
m

Reboot the machine. *2

S.C.
S.C.
S.C.

An incorrect hash value was detected in resident (directly mounted) font ROM in CU
board.
An incorrect hash value was detected in the font ROM installed in DIMM slot 1 (A)
in CU board. (Only for Japanese Non-PS model)
An incorrect hash value was detected in the font ROM installed in DIMM slot 2 (B)
in CU board. (Only for Japanese PS model)
An incorrect hash value was detected in the font ROM installed in DIMM slot 3 (C)
in CU board.
An incorrect hash value was detected in somewhere other than the above DIMM
slots in CU board.

If rebooting the machine does not improve the symptom, you need
to check the device.
The data in the font ROM (or Flash) may be damaged or font ROM
that is not compatible with the CU firm (different version) may be
installed.

S.C.

S.C.

S.C.

S.C.

S.C.

The behavior of the RAM installed in slot 1 was checked and a problem was
detected.
The behavior of the RAM installed in slot 2 was checked and a problem was
detected.
The behavior of the RAM installed in slot 3 was checked and a problem was
The behavior of the RAM installed in slot 4 was checked and a problem was

If rebooting the machine does not improve the symptom, you need
to replace the device.

S.C.

S.C.

S.C.
S.C.

m
-

031

CU RAM Check Error (RAM slot 1)

032
033

CU RAM Check Error (RAM slot 2)


CU RAM Check Error (3rd option) <Reserved>

034
035
036
037
038
039

RAM Configuration Error


Slot1 RAM Spec Error
Slot1 RAM Spec Error
Slot2 RAM Spec Error
Slot4 RAM Spec Error <Reserved>
<Not assigned>

RAM installation order is not correct.


RAM that does not meet the spec was installed in slot 1.
RAM that does not meet the spec was installed in slot 2.
RAM that does not meet the spec was installed in slot 3.
RAM that does not meet the spec was installed in slot 4.

Check with the spec document, and install RAM in the correct
Check with the spec document, and install the RAM whose spec
the product supports.

S.C.
S.C.
S.C.
S.C.
S.C.

040

CU EEPROM Error

If rebooting the machine does not improve the symptom, you need
to replace the device.

CU Flash Memory Error

S.C.

042

Flash File System Error

The behavior of EEPROM installed in CU board was checked, and a problem was
detected.
The behavior of Flash memory installed in CU board was checked, and a problem
was detected.
Initialization of Flash memory as DOS file system (TrueFFS) failed.

S.C.

041

S.C.

043

Flash File System Version Mismatch

The format version of Flash is different from the format version that the program

If rebooting and initializing Flash does not improve the symptom,


you need to check the device. (A problem in Flash memory is
possible.)

S.C.

044
045

PS Flash File System Error


Flash File System Recovery Failed

Initialization of Flash file system failed for PostScript requirement.


Formatting the Flash file system was failed, so as to recover S/C042 error.

S.C.
S.C.

046~047 <Not assigned>


048
PS Protection

049
050
051
052

CU Engine Type Mismatch


Operator Panel Error<Reserved>
CU Fan Error
Image Processor Driver Error

053~059
060
061
062
063

<Not assigned>
Parallel Interface Driver Error
Serial (RS232C) Driver Error <Reserved>
USB Driver Error
PCI Driver Open error

064
065
066~069
070

<Reserved>
NIC Combination Error <Reserved>
<Not assigned>
PostScript Internal Error

c969800ErrorCodes.xls

If rebooting and initializing Flash does not improve the symptom,


the CU board needs to be replaced.

m
m
-

m
m

PS ROM is installed into Non-PS machine.

Replace the CU ROM with the correct one for the model.

S.C.

When the EFI controller was installed into 600dpi printing engine, this error should
A problem with the operator panel controller was detected.
The FAN intended to cool down the CU stopped or strangely behaved.
A problem was detected with image processing LSI; not detecting response to DMA
abort or LSI initialization.

Replace the CU board with the correct one for the head model.

S.C.
S.C.
S.C.
P.O.

CONF

m
m

m
m
m

If rebooting the machine does not improve the symptom, you need
to replace the device.
If rebooting the machine does not improve the symptom, you need
to replace the device.

Damage of network device or an error close to it was detected.

If rebooting the machine does not improve the symptom, you need
to replace the device.

P.O.

You installed NIC that is not compatible with the printer.

Replace the NIC with a compatible one.

S.C.

An error was detected in PostScript core.

If an address is displayed in LCD, record it and reboot.

P.O.

ServiceCalls

Efi Supported
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

No
No
No
No
No
No
No
No
No
No
No
No
No
No

1/4

Oki Data Confidential


Fatal No.

Name

Occurs under the following condition.

How to handle

Display *1

071

Video Overrun detect <Reserved>

072
073

Engine Communication Error


H/W Overrun detect

A communication error happened between CU and PU.


A image processing controller could not send data to the engine fast enough.

074

F/W Overrun detect

CPU program could not set the video data to meet VideoDMA request.

P.O.

075
076

Video Interface Error


VIC Decomp Write Error <Reserved>

The video parameter was not meet the image processing controller.

P.O.

077
VIC Illegal Decomp Error <Reserved>
078~079 <Not assigned>
080
Parameter I/O Error
081

Parameter Consistency Check Error

082~089 <Not assigned>


090
Finisher Stapler Error <Reserved>
091
Finisher Tray Elevator Error <Reserved>

Record the 2 digit number displayed in the right bottom line in LCD,
Reboot. Keep the print result when the problem happened. *2

Access failure to parameter storage location due to file damage or etc.


Consistency error was detected in the parameters.

Finisher stapler error (for the PX703/713 Finisher)


Finisher tray elevator motor error (for the PX703/713 Finisher)

Finisher Bin2 Exit Belt Motor Error <Reserved>


Finisher Jogging Motor Error <Reserved>

Finisher bin 2 exit belt motor error (for the PX703/713 Finisher)
Finisher jogging motor error (for the PX703/713 Finisher)

094

Finisher Main Feed Motor Error <Reserved>

Finisher main feed motor error (for the PX703/713 Finisher)

095
096

<Not assigned>
Finisher Unrecoverable Error

097

Inverter Power Supply Error

01 : An error was detected with the exit motor of the finisher.


02 : An error was detected with the tray lifting motor of the finisher.
03 : An error was detected with the jogger motor of the finisher.
04 : An error was detected with the staple motor (staple/folder) of the finisher.
05 : An error was detected with the paper stack handling motor of the finisher.
06 : An error was detected with the stapler unit swing motor of the finisher.
07 : An error was detected with the puddle motor of the finisher.
08 : An error was detected with the folder sensor of the finisher.
09 : An error was detected with the backup RAM of the finisher.
0A : An error was detected with the punch motor of the finisher.
0B : An error was detected with the punch unit transfer motor of the finisher.
0C : An error was detected with communication with the punch unit of the finisher.
0D : The power failure of the punch unit was detected.
0E : An error was detected with the punch backup RAM of the finisher.
0F : An error was detected with the punch registration sensor of the finisher.
10 : An error was detected with the punch side registration sensor of the finisher.
11 : An error was detected with the punch dust sensor of the finisher.
24V could not be detected in spite that 24V drive voltage in the inverter is on.

<Not assigned>
Engine Program Hash Check Error <Reserved>
Engine Loader Hash Check Error <Reserved>
Engine RAM Error
or Belt stuck Error (PX723)
Engine SRAM Error

At POW ON, an error was detected in RAM reading/writing.


On PX723, the belt stuck error was detected.
At POW ON, an error was detected in static RAM writing/reading.

103
104
105
106
107
108~109
110

At POW ON, an error was detected in EEPROM reading/writing.


At POW ON, EEPROM was not detected.
An error was detected in engine control logic.
At POW ON, an error was detected in ROM sumcheck.

111

Illegal Duplex Unit

112
113

Illegal Tray2 Unit


Illegal Tray3 Unit

As a duplex unit, an unsupported version was detected on a connection check;


perhaps an invalid model of the unit.
As a 2nd tray unit, an unsupported version was detected on a connection check.
As a 3rd tray unit, an unsupported version was detected on a connection check.

Envelope Feeder Unit for a different model was detected.

m
m
m

m
-

P.O.

S.C.

If rebooting the machine does not improve the symptom, you need
to have the finisher serviced.

S.C.
S.C.

HW/FIN1 #4
HW/FIN1 #3

S.C.
S.C.

HW/FIN1 #2
HW/FIN1 #1

S.C.

HW/FIN1 #0

If rebooting the machine does not improve the symptom, you need
to have the finisher serviced.

S.C.

If rebooting the machine does not improve the symptom, you need
to have the finisher/inverter serviced.

S.C.

HW/FIN1 #0
HW/FIN1 #1
HW/FIN1 #2
HW/FIN1 #3
HW/FIN1 #4
HW/FIN1 #5
HW/FIN1 #6
HW/FIN1 #7
HW/FIN2 #0
HW/FIN2 #1
HW/FIN2 #2
HW/FIN2 #3
HW/FIN2 #4
HW/FIN2 #5
HW/FIN2 #6
HW/FIN2 #7
HW/FIN3 #0
HW/INV1 #0

S.C.
S.C.
S.C.

HW/PCU #5

S.C.

HW/PCU #2

S.C.
S.C.
S.C.
S.C.

HW/PCU #4
HW/PCU #3
HW/PCU #1
HW/PCU #6

m
m
m
-

S.C.

S.C.

OPTROMERR #5

S.C.
S.C.

OPTROMERR #1
OPTROMERR #2

m
m

S.C.
S.C.
S.C.
S.C.

OPTROMERR #3
OPTROMERR #4
OPTROMERR #6
OPTROMERR #7

m
m
m
m

POW OFF and remove the unit. If the error appears even though
you install the correct unit for the printer, you need to check each
unit of the device
POW OFF and remove the unit. If the error appears even though
you install the correct unit for the printer, you need to check each
unit of the device.

Illegal Tray4 Unit


Illegal Tray5 Unit
Illegal Finisher Unit
Illegal Inverter Unit
<Not assigned>
PU Board Fan Motor Error

As a 4th tray unit, an unsupported version was detected on a connection check.


As a 5th tray unit, an unsupported version was detected on a connection check.
As a finisher unit, an unsupported version was detected on a connection check.
As an inverter unit, an unsupported version was detected on a connection check.

121
122

Power Supply LSI Error


Power Supply Fan Motor Error

123

Humidity Sensor

A communication error with high voltage LSI was detected.


Low voltage power supply unit temperature alarm was detected or an anomaly was
detected in fuser exhaust ventilation fan/power supply unit cooling fan.
*ODC(600dpi) do not display Same as 128(02)
The sensor detected an anomaly in ambient humidity or humidity sensor is not

124
125
126

Temperature Sensor
Multi-purpose Tray Home Error
Sensor Dewed Error

The sensor detected an anomaly in ambient temperature.


An error was detected in front feeder home position.
A condensation error was detected.

127

Fuser Unit Fan Error

An error was detected in fuser cooling fan.


*ODC(600dpi) do not display. Same as 128(01).

128

Engine Fan Motor Error

01 : An error was detected with the cooling fan of fuser unit.


02 : An error was detected with the engine power supply cooling fan.
03 : An error was detected with the engine cavity cooling fan.
04 : An error was detected with the belt cooling fan.
05 : An error was detected with the image drum cooling fan.
06 : An error was detected with the top cover cooling fan.

If rebooting the machine does not improve the symptom, you need
to check the device.

129

<Not assigned>

130

LED Head Over Temperature

A high temperature anomaly was detected in LED head.

131
132

Yellow LED Head Missing


Magenta LED Head Missing

A yellow LED head connection was not detected.


A magenta LED head connection was not detected.

If rebooting the machine does not improve the symptom, you need
If rebooting the machine does not improve the symptom, you need
to check the device.

133
134

Cyan LED Head Missing


Black LED Head Missing

A cyan LED head connection was not detected.


A black LED head connection was not detected.

If rebooting the machine does not improve the symptom, you need
to check the device.

An error was detected in PU board cooling fan.


*ODC(600dpi) do not display. Same as 128(03).

P.O.
P.O.

If rebooting the machine does not improve the symptom, you need
to check the device.
Reformatting EEPROM/FLASH and then initialization by service
personnel is needed.

If rebooting the machine does not improve the symptom, you need
to check the device.

Engine EEPROM Error


Engine EEPROM Missing Error
Engine Control Error
Engine ROM error
<Not assigned>
Illegal Envelope Feeder Unit <Reserved>

114
115
116
117
118~119
120

PX723

092
093

098~099
100
101
102

Leisus I/F

Wait for a while and power ON.


LCD displays "POW OFF and wait for a while. / 126:Condensation
If rebooting the machine does not improve the symptom, you need
to check the device.

Efi Supported
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No

S.C.

HW/IO1 #3

S.C.
S.C.

HW/PCU #0
HW/IO1 #2

m
-

S.C.

HW/IO2 #3

S.C.
S.C.
P.O.

HW/IO2 #4
HW/IO1 #4
HW/IO2 #5

m
m
m

S.C.

HW/IO1 #1

S.C.

HW/FAN #0
HW/FAN #1
HW/FAN #2
HW/FAN #3
HW/FAN #4
HW/FAN #5

Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes

135~139 <Not assigned>


140
Yellow Image Drum Up/Down Sensor Error
141

Magenta Image Drum Up/Down Sensor Error

142

Cyan Image Drum Up/Down Sensor Error

c969800ErrorCodes.xls

An abnormal Yellow image drum installation position was detected.


PX723: A yellow image drum motor was out of control on its up/down driving.
An abnormal Magenta image drum installation position was detected.
PX723: A magenta image drum motor was out of control on its up/down driving.
An abnormal Cyan image drum installation position was detected.
PX723: A cyan image drum motor was out of control on its up/down driving, or an
error was occurred with the image drum up/down detecting sensor

If rebooting the machine does not improve the symptom, you need
to check the device.

ServiceCalls

Yes

S.C.

HW/IO2 #0

S.C.
S.C.

HW/IMAG #3
HW/IMAG #2

m
m

S.C.
S.C.

HW/IMAG #1
HW/IMAG #0

m
m

S.C.

HW/XER #3

S.C.

HW/XER #2

S.C.

HW/XER #1

No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes

2/4

Oki Data Confidential


Fatal No.

Name

Occurs under the following condition.

143
144
145
146

Black Image Drum Up/Down Sensor Error


Yellow Toner Supply Switch Error
Magenta Toner Supply Switch Error
Cyan Toner Supply Switch Error

An error was detected with the yellow toner supply mechanism sensor.
An error was detected with the magenta toner supply mechanism sensor.
An error was detected with the cyan toner supply mechanism sensor.

147

Black Toner Supply Switch Error

An error was detected with the black toner supply mechanism sensor.

148~149 <Not assigned>


150
Yellow Image Drum Fuse Cut Error

If rebooting the machine does not improve the symptom, you need
to check the device.

If rebooting the machine does not improve the symptom, you need
to check the device.

At POW ON, Yellow drum fuse cut error was detected.

151
152
153

Magenta Image Drum Fuse Cut Error


Cyan Image Drum Fuse Cut Error
Black Image Drum Fuse Cut Error

At POW ON, Magenta drum fuse cut error was detected.


At POW ON, Cyan drum fuse cut error was detected.
At POW ON, Black drum fuse cut error was detected.

154
155

Belt unit Fuse Cut Error


Fuser unit Fuse Cut Error

At POW ON, belt unit fuse cut error was detected.


At POW ON, fuser unit fuse cut error was detected.

156~159 <Not assigned>


160
Yellow Toner Sensor Error

How to handle

You need to check the device. *3

Yellow toner sensor error happened. (In Factory mode only)

Display *1

Leisus I/F

PX723

S.C.
S.C.
S.C.
S.C.

HW/XER #0
HW/XER2 #3
HW/XER2 #2
HW/XER2 #1

m
m
m

S.C.

HW/XER2 #0

S.C.

HW/FUSE #3

S.C.
S.C.
S.C.

HW/FUSE #2
HW/FUSE #1
HW/FUSE #0

m
m
m

S.C.
S.C.

HW/FUSE #4
HW/FUSE #5

m
m

S.C.

HW/TONER #3

161

Magenta Toner Sensor Error

Magenta toner sensor error happened. (in Factory mode only)

S.C.

HW/TONER #2

162
163

Cyan Toner Sensor Error


Black Toner Sensor Error

Cyan toner sensor error happened. (in Factory mode only)


Black toner sensor error happened. (in Factory mode only)

S.C.
S.C.

HW/TONER #1
HW/TONER #0

164
165

Waste Toner Sensor Error <Reserved>


Waste Toner Full <Reserved>

S.C.
S.C.

166

<Not assigned>

167

Thermistor Slope Error

The heat roller thermistor is detected out of control.

168

Compensation Thermistor Error

01 : The compensation thermistor is detected as shorted.


02 : The compensation thermistor is detected as open..
03 : The compensation thermistor indicates high temperature error.
04 : The compensation thermistor indicates low temperature error.

169

Upper Side Thermistor Error

170
171
172
173
174
175
176

POW OFF, and reboot after the temperature drops. If it does not
recover, you need to check the device.
POW OFF, and reboot after the temperature drops. If it does not
recover, you need to check the device.

S.C.

HW/IO3 #3

S.C.

HW/FSR2 #3
HW/FSR2 #2
HW/FSR2 #1
HW/FSR2 #0

01 : The upper side thermistor is detected as shorted.


02 : The upper side thermistor is detected as open..
03 : The upper side thermistor indicates high temperature error.
04 : The upper side thermistor indicates low temperature error.

POW OFF, and reboot after the temperature drops. If it does not
recover, you need to check the device.

S.C.

HW/FSR2 #7
HW/FSR2 #6
HW/FSR2 #5
HW/FSR2 #4

Upper Thermister Circuit Shortened


Upper Thermister Circuit Opened
Upper Heater High Temperature
Upper Heater Low Temperature
Lower Thermister Circuit Shortened
Lower Thermister Circuit opened
Lower Heater High Temperature

Heat roller thermister short was detected (in case of high temperature)
Heat roller thermister open was detected (in case of low temperature).
Heat roller thermister indicates a high temperature error.
Heat roller thermister indicates a low temperature error.
Back up roller thermister short was detected (in case of high temperature).
Back up roller thermister open was detected (in case of low temperature).
Back up roller thermister indicates a high temperature error.

If rebooting the machine does not improve the symptom, you need
to check the device.

S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.

HW/FSR #7
HW/FSR #6
HW/FSR #5
HW/FSR #4
HW/FSR #3
HW/FSR #2
HW/FSR #1

m
m
m
m
m
m
m

177

Lower Heater Low Temperature

Back up roller thermister indicates a low temperature error.

S.C.

HW/FSR #0

178
179
180
181
182
183
184
185
186
187
188
189

Drive Roller Over Temperature <Reserved>


Fuser Mismatch
Envelop feeder I/F Error
Duplex Unit I/F Error
Tray2 Unit I/F Error
Tray3 Unit I/F Error
Tray4 Unit I/F Error
Tray5 Unit I/F Error
Finisher Unit I/F Error
Engine Control Panel I/F Error
Sub-CPU I/F Error
Inverter Unit I/F Error

Fuser spec does not match.


Communication with Envelope Feeder was cut.
Communication with Duplex Unit was cut.
Communication with Tray2 was cut.
Communication with Tray3 was cut.
Communication with Tray4 was cut.
Communication with Tray5 was cut.
Communication with Finisher was cut.
Communication with Control Panel was cut.
Communication with Engine Sub-CPU was cut.
Communication with Inverter was cut.

You need to check the device.

S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.
S.C.

HW/FSR #4, #5
HW/OPT1 #3
HW/OPT1 #1
HW/OPT1 #2
HW/OPT2 #0
HW/OPT2 #3
HW/OPT2 #1
HW/IO1 #6
HW/OPT1 #0
HW/OPT2 #2

m
m
m
m
m
m
m
m
m

System Memory Overflow


Page Memory Overflow<Reserved>
<Not assigned>
PU F/W download Check Sum Error
PU F/W Flash Write Error

System memory overflows.


Page memory overflows.

Reboot
Reboot

P.O.
P.O.

m
-

A check-sum confirmation error was occurred in PU F/W downloading file.


Reboot and do PU Flash Download again.
No response was detected for Flash Download Command on PU F/W downloading.

S.C.
S.C.

m
m

202
203
204

PU F/W Flash Data Missing


EnginePageSequencer IMGACK Error
EnginePageSequencer IMGSET Error

A value of file size was not correct in a header part of the PU F/W downloading file.
Record the string displayed in the bottom line in LCD, and reboot.
Reboot. *2

S.C.
P.O.
P.O.

205
206
207

<Reserved>
<Reserved>
EnginePageSequencer illegal Function Call

CU program error (No Page DUPIN - not used)


CU program error (No Page PPOUT - not used)
CU program error (OKI Controller only)

Reboot. *2

P.O.
P.O.
P.O.

208
209

EnginePageSequencer Parameter Error


Media Table Download Failure

MediaTable Download to PU failed.

Reboot. *2

P.O.
P.O.

210
211
212

EngineControl illegal Page Cargo


EngineControl Page Error
EngineControl Video Queue Error

CU program error (OKI Controller only)

Reboot. *2

P.O.
P.O.
P.O.

213

EngineControl Print Sequence Error


PrintScheduler Illegal Sequence
<Not assigned>
Print Statistic No-match HDD
<Not assigned>

CU detected a PU program error. (OKI Controller only)

Reboot. *2

P.O.

Print Statistics System is set to ON and HDD was removed or replaced.

Get the original HDD back.

S.C.

230

RFID Reader not installed

The RFID reader device cannot be detected.

If rebooting the machine does not improve the symptom, you need
to check the device.

S.C.

HW/RFID #0

231

RFID Reader I/F Error

An interface error was detected with the RFID reader device.


01 : communication error between the RFID reader and the engine PCB.
02 : the transceiver circuit error of the RFID reader.
03 : communication error between the RFID reader and the Tag chip.
04 : the RFID Tag detection error (more than 4 chips)

If rebooting the machine does not improve the symptom, you need
to check the device.

S.C.

HW/RFID #1~4

If rebooting the machine does not improve the symptom, you need
to check the device.

S.C.

FLASH2 #0

S.C.

FLASH2 #5

190
191
192~199
200
201

214
215~219
220
221~229

CU program error (OKI Controller only)

POW OFF, and reboot after the temperature drops. If it does not
If the symptom does not improve even though you reboot, you need
to check the device.
POW OFF, and reboot after the temperature drops.
If it does not recover, you need to check the device.
If rebooting the machine does not improve the symptom, you need
to check the device.

If rebooting the machine does not improve the symptom, you need
to check the device.

P.O.

Efi Supported
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
Yes

Yes

m
m
m
m
m
m
m
m
m
m
m

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

Yes

232~239 <Not Assigned>

Yes

240

Engine Program Memory Error

The engine detects a hardware error in a flash memory.

241

Duplex Unit Program Memory Error

The engine detects a H/W error in a flash memory of the duplex unit.

242

Option Tray2 Program Memory Error

The engine detects a H/W error in a flash memory of the option tray2.

S.C.

FLASH2 #1

243
244

Option Tray3 Program Memory Error


Option Tray4 Program Memory Error

The engine detects a H/W error in a flash memory of the option tray3.
The engine detects a H/W error in a flash memory of the option tray4.

S.C.
S.C.

FLASH2 #2
FLASH2 #3

m
m

245
246

Option Tray5 Program Memory Error


<Not Assigned>

The engine detects a H/W error in a flash memory of the option tray5.

S.C.

FLASH2 #4

c969800ErrorCodes.xls

ServiceCalls

Yes
Yes
Yes
Yes
Yes
Yes

3/4

Oki Data Confidential


Fatal No.
247
248
249~299
300~900

Name

Occurs under the following condition.

How to handle

Engine Sub-CPU Program Memory Error


Inverter Program Memory Error
<Not Assigned>
<Reserved>

The engine detects a H/W error in a flash memory of the Sub-CPU.


The engine detects a H/W error in a flash memory of the inverter.

901

Belt Thermister Error; Shorten

Belt thermister short error (A thermister failure is assumed. 120C or higher)

902

Belt Thermister Error; Open

903

Belt Thermister Error; High Temperature

Belt thermister open error (A thermister failure or a connection error is assumed. 10C or lower)
Belt thermister high temperature error (70C or higher assumed)
Belt thermister low temperature error (0C or less assumed)

904
Belt Thermister Error; Low Temperature
905~909 <Reserved>
910

Tray1 GDDC Error

An error was detected with the geared motor (Tray1)

911
912

Tray2 GDDC Error


Tray3 GDDC Error

(Tray2)
(Tray3)

913
914

Tray4 GDDC Error


Tray5 GDDC Error

(Tray4)
(Tray5)

If rebooting the machine does not improve the symptom, you need
to check the device.
These numbers are assigned for errors that may be recovered by a
user.
If rebooting the machine does not improve the symptom, you need
to check the device.

If rebooting the machine does not improve the symptom, you need
to check the device. (Tray1)
(Tray2)
(Tray3)
(Tray4)
(Tray5)

Display *1

Leisus I/F

PX723

S.C.
S.C.

FLASH2 #6
FLASH2 #7

m
m

P.O.

PUSC #0~#7

P.O.

PUSC #0~#7

P.O.

PUSC #0~#7

P.O.

PUSC #0~#7

No

P.O.

PUSC #0~#7

P.O.
P.O.

PUSC #0~#7
PUSC #0~#7

m
m

P.O.
P.O.

PUSC #0~#7
PUSC #0~#7

m
m

915~916 <Reserved>
917

Belt Slit Sensor Error

An error was detected with the belt rotation sensor.

918

Duplex FAN0 Alarm Detection

An error was detected with Duplex FAN motor.

919
920

Duplex 24V Abnormal Current Detection


Yellow Image Drum Lock Error

24V power isn't supplied (Duplex unit).


An error was detected with Drum Motor rotation by overload. (Yellow ID)

921

Magenta Image Drum Lock Error

(Magenta ID)

922
923

Cyan Image Drum Lock Error


Black Image Drum Lock Error

(Cyan ID)
(Black ID)

924
925

Tray2 24V Abnormal Voltage Detection


Tray3 24V Abnormal Voltage Detection

24V power isn't supplied (Tray2 unit).


(Tray3 unit).

926
927
928

Tray4 24V Abnormal Voltage Detection


Tray5 24V Abnormal Voltage Detection
Fuser Motor Lock Error

(Tray4 unit).
(Tray5 unit).
An error was detected with Fuser Motor rotation by overload.

929

Waste Toner Transfer Motor Lock Error

An error was detected with Toner Transfer Motor rotation by overload.

930

Sub-CPU Clock Frequency Error

Clock frequency of sub-CPU is detected out of permissible range.

931

Duplex CPU Clock Frequency Error

Clock frequency of Option unit is detected out of permissible range.(Duplex)

932
933
934
935
936
937~939
940

Inverter CPU Clock Frequency Error


Tray2 CPU Clock Frequency Error
Tray3 CPU Clock Frequency Error
Tray4 CPU Clock Frequency Error
Tray5 CPU Clock Frequency Error
<Reserved>
Waste Toner Transfer Error

941~999 <Reserved>
0xF0C
0xF0D
0xFFE

System Call Exception


Trace Exception
Bus Controller H/W Break Point

0xFFF

Bus Controller ROM Write Protection

c969800ErrorCodes.xls

If rebooting the machine does not improve the symptom, you need
to check the device. (Slit sensor)
Check Duplex FAN connector , Duplex connector and Duplex unit.

Reserved for Engine F/W Notification


An error was detected with Waste Toner Transfer duct by overload.
Reserved for Engine F/W Notification
The program referred to an illegal address.

P.O.

PUSC #0~#7

P.O.

PUSC #0~#7

P.O.
P.O.

PUSC #0~#7
PUSC #0~#7

m
m

P.O.

PUSC #0~#7

P.O.
P.O.

PUSC #0~#7
PUSC #0~#7

m
m

Check Tray-n connector and Tray-n unit.(Tray2 unit)


(Tray3 unit).

P.O.
P.O.

PUSC #0~#7
PUSC #0~#7

m
m

(Tray4 unit).
(Tray5 unit).
If rebooting the machine does not improve the symptom, you need
to check the device. (Fuser Unit)
If rebooting the machine does not improve the symptom, you need
to check the device (Toner Transfer Motor) and clean Waste Toner
duct and box
If rebooting the machine does not improve the symptom, you need
to change S2M board.
If rebooting the machine does not improve the symptom, you need
to change the board.(Duplex)
(Inverter unit)
(Tray2 unit)
(Tray3 unit)
(Tray4 unit)
(Tray5 unit)

P.O.
P.O.
P.O.

PUSC #0~#7
PUSC #0~#7
PUSC #0~#7

m
m
m

P.O.

PUSC #0~#7

P.O.

PUSC #0~#7

P.O.

PUSC #0~#7

P.O.
P.O.
P.O.
P.O.
P.O.

PUSC #0~#7
PUSC #0~#7
PUSC #0~#7
PUSC #0~#7
PUSC #0~#7

If rebooting the machine does not improve the symptom, you need
to check the device (Duct rotation sensor) and clean Waste Toner
duct and box

P.O.

PUSC #0~#7

m
m
m
m
m
m

Record the information displayed on LCD (max. 3 lines of hexadecimal numbers) and reboot. *2

S.C.
S.C.
S.C.

Check Duplex connector and Duplex unit.


If rebooting the machine does not improve the symptom, you need
to check the device. (Yellow-ID)
(Magenta ID)
(Cyan ID)
(Black ID)

Record the information displayed on LCD (if existing) and reboot. *2

No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

S.C.

ServiceCalls

Efi Supported
Yes
Yes
No

m
m
m
m

Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
No

4/4

Potrebbero piacerti anche