Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
General
1
1.1
Engineering design drawings shall be prepared based on approved /agreed over all equipment layout
Dewa Practice
1.2
Engineering design drawings shall be submitted to DEWA as per priority highlighted in DDCMS list .
Dewa Practice
1.3
Engineering design drawings shall be provided with List of required legends and reference of related drawing.
Dewa Practice
1.4
1.5
DEWA approved title Blocks only to be used for each drawings. Drawing number and drawing title must be same as indicated in
DDCMS.
DEWA approval status of reference drawings to be indicated in reference list respectively.
Dewa Practice
Dewa Practice
1.6
Major references drawings to be provided to Dewa Engineers in time to avoid delay in approval process.
Dewa Practice
1.7
Revision number and date shall be maintained based on revised submission to DEWA only.
Dewa Practice
1.8
Engineering design drawings shall be prepared signed and endorsed by approved consultant prior to submission to DEWA for
approval .
Dewa Practice
Engineering
2
2.1
Introduction about the substation type ,its capacity ,contract number should be mentioned.
Dewa Practice
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
2.2
2.3
2.4
Category
Dewa Practice
Standard
Dewa Specification
2.4.1 All Designs shall be prepared in accordance with British Standards and code of practices .
Dewa Specification
2.4.2 All British codes referred in the Design ,construction ,steel work ,Drainage ,masonry ,earth work , shall be listed .Any British Code not
listed shall also be considered.
Standard
2.4.3 Seismic Analysis shall be as per UBC 97 ; Seismic zone shall be 2B as per lattest DM regulations.
Standard
Standard
2.5
2.5.1 Breakage of all loads (self weight ,imposed dead weight and live or equipment loads )on the Roof ,First floor ,Ground floor and the
basement shall be given as per the standard design criteria.
Dewa Specification
2.5.2 Dead loads shall comprise of the self weight of the structure multiplied by the density and the self imposed dead loads
of the structures like the walls ,finishes ,services ,pipes etc.
Standard
2.5.3 Live loads shall as per the as per BS 6399 or manufacturers specification ,whichever is stringent.Equipment loads are to be
considered as live loads .
Standard
2.5.4 Surcharge loads due to heavy vehicle load of 33.3 kn/m2 should be used in design of all underground structures should be mentioned.
Standard
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
2.5.5 Lateral Earth pressure on walls of basement and tanks shall be calculated with coefficient of earth pressure at rest as per the soil
Report.
Standard
2.5.6 Basic wind loads shall be considered and dynamic wind pressure to be calculated as per the building location conditions as per BS
6399
Standard
2.5.7 Seismic loads shall be considered for seismic zone 2A and base shear calculated as per parameters of the structure as per UBC 97
Standard
2.5.8 Blast load of 5 kn/m2 shall be considered in design of Transformer and Reactor internal walls.
Dewa Specification
2.5.9 Crane loads shall be checked for the vertical and horizontal load percentages to be increased for electric overhead crane and hand
operated cranes.
Dewa Specification
2.5.10 The capacity of the electrically operated crane of 5 MT capacity in the 132 kv GIS and monorail load of 2.0 MT capaciy in the fire
pump house roof of switchgear control building offloading area shall be checked as live loads.
Dewa Specification
Standard
2.6.2 Unit weight of soil under saturated condition and unit weight of water is to be checked.All hydrostaic loads to be considered as dead
loads.
Standard
2.7
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
2.7.1 Analysis shall be performed using a 3 dimensional structural analysis software that takes care of all aspects of designing like model
development ,analysis,verification and visualization.ETAB'S ,STAAD PRO ,SAFE and SAP are to be mentioned in the calculations.
Dewa Practice
2.80 Input data for the beams and columns are to be defined as frames members ,slabs as membrane ,walls as shells and the connection at
the base level as fixed.Raft will be designed by exporting all reactions from ETABS and defining the subgrade modulus as per soil
report.In STAAD PRO an integrate model can be directly designed.
Standard
2.9
ANALYSIS RESULTS
2.9.1 All computer generated results such as member forces ,support reactions ,displacements and graphical output of analysis such as
bending moment ,shear force diagram,displacement to substantiate the numerical output to be checked.
Dewa Practice
Dewa Specification
2.10.2 Grade of concrete for design shall be grade C40 with compressive strength of 35 N/mm2 @28days
Dewa Specification
2.10.3 Grade of concrete for construction shall be C40 with compressive strength of 40N/mm2 @ 28 days.
Dewa Specification
Dewa Specification
2.10.5 Blinding and plain cement concrete -C20 with compressive strength of 15N/mm2 @ 28 days.
Dewa Specification
Dewa Specification
2.10.7 Grade of Steel considered shall be Grade 420 for Design purpose.
Dewa Specification
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
Dewa Specification
Dewa Specification
2.22.10.106.4
Welded wire mesh shall comply with BS 4483
Standard
2.10.11 Material Strengths and allowable stresses shall be as per BS 8110 Part 1 & 2.
Standard
2.10.12 Maximum shear stress at any section shall not exceed 4.73 N/mm2.
Standard
Standard
Standard
Standard
Standard
Standard
2.11.1 Loads & load combinations for dead ,imposed ,wind ,seismic ,earth and crane loads ( ultimate and service conditions) shall be given as
per the standard design criteria.
Dewa Specification
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
2.12.1 Check for the minimum safety factors for overturning in SLS condition: 1.5
Standard
Standard
Standard
2.13 DESIGN
2.13.1 Design should be done for both servisibility and ultimate conditions for worst combinations of loads.
2.13.2 Design of Structural Elements shall be performed using the latest sofwares.
Standard
Dewa Specification
Standard
2.14.1 Clear cover to reinforcement for members in contact with soil =75 mm
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
2.15.1 Anchorage length and lap length shall as indicated in table 3.27 of BS 8110 Part 1.
2.16 FOUNDATION
All rights reserved TED-2015
Standard
Standard
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
2.16.1 Raft foundation is proposed for main as well as for all ancilliary buildings.All soil parameters shall be
as per the soil report .Safe bearing capacity ,water table level shall be a per soil report.
Dewa Specification
2.16.2 Allowable Settlement shall be 25 mm as per specification and differentiak settlement 10 mm.
Dewa Specification
2.16.3 Retaining walls shall be designed for worst combination of earth pressure ,hydroststic pressure & surcharge
as applicable.
Dewa Specification
2.17 MASONRY
Dewa Specification
2.17.1 Masonry :the minimum characteristic strength of non-load bearing walls shall be 7 N/mm2.
2.17.2 Internal walls shall be 200 mm thick single leaf hollow block work
Dewa Specification
2.17.3 External wall shall be 250 /350 mm thick thermal block wall
Dewa Specification
Dewa Specification
2.18 DETAILING
2.18.1 Detailing :shall be as per british standards of practice and preparation of bar bending schedules will conform to BS 4466.
Standard
Standard
2.19.2 Moment Capacity and deflection of the steel members shall be calculated based on BS 5950
Standard
Standard
2.19.4 Bolt design shall cpmply with BS 3692 & BS 4190 (Minimum no of bolts at any joint shall be two)
Standard
2.19.5 Minimum size of the weld should 6mm and electrode classification should be based on table 37 of BS 5050
Standard
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
Dewa Specification
Inspection
3
3.1
3.2
4
4.1
4.2
5
5.1
5.2
Maintenance
6
6.1
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
6.2
Nasreen Mir
Prepared By:
Checked By:
Approv
CL-Rev.1
Document Title
Document Number
Rev.
KHORDXB/C/15/316
SR. Description
Category
Mariam Abdullah Al Suwaidhi
Srinivas Kupuswamy
Zeenat Pasha
Nasreen Mir
Prepared By:
Checked By:
Approv
Khawla Saleh Aldhebaiei
10
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Noted
Noted
Noted
Noted
Noted
Noted
Noted
Noted
Complied
11
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Complied
Complied
Complied
BS 8110
Complied
UBC 97
Zone-2A
BS 6399
Complied
Complied
Complied
BS 8110
Complied
BS 8110
Complied
12
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
BS 8110
Complied
BS 6399
Complied
UBC 97
Complied
Complied
Complied
Complied
BS 8110
Complied
BS 8110
Complied
13
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Complied
BS 8110
Complied
Complied
14
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Grade 500
Complied
Bs 4483
Complied
BS 8110
Complied
BS 8110
5 N/mm2
BS 8110
As per compressive
strength of concrete
BS 8110
As per compressive
strength of concrete
BS 8110
As per compressive
strength of concrete
BS 8110
Complied
BS 8110
Complied
15
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
BS 8110
Complied
BS 8110
Complied
BS 8110
Complied
BS 8110
BS 8110
Complied
Complied
BS 8110
Complied
BS 8110
Complied
BS 8110
Complied
BS 8110
Complied
BS 8110
40 mm
BS 8110
Complied
BS 8110
Complied
BS 8110
BS 8110
Complied
BS 8110
All rights reserved TED-2015
16
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Complied
Complied
Complied
Complied
Complied
Complied
Complied
BS 4466
Complied
BS 5950 PART 1
Complied
BS 5950
Complied
BS 5950 PART 1
Complied
BS 5950 PART 1
Complied
BS 5950 PART 1
Complied
17
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Complied
18
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Approved By:
19
CL-Rev.1
Date
Approval Status
9/23/2016
Applicable Reference
Complied with
Approved By:
20
CL-Rev.1