Sei sulla pagina 1di 42

INDEX

TECHNICAL FEATURES
COMPONENT SPECIFICATIONS
ENERGY LABEL
NAME PLATE
FAILURE CODES
AUTO TEST CHART
DETERGENT BOX GROUP WORK PRINCIPLE
CHILD LOCK MANUAL
AUTOTEST MANUAL

Technical Features
Capacity

: 4 kg, 5 kg, 6 kg, 7 kg,

Colour

: White

Spinning

: 400 RPM, 500 RPM, 600 RPM, 800 RPM, 1000

RPM, 1400 RPM ,


Voltage

: 220-240 V

Frequency

: 50 Hz

Ampere

: 10 A

Total electrical power

: 2100 W

Component specifications
DOOR LOCK

Door lock is activated at the beginning of the program in


order to prevent the door from opening. It can be
unlocked approximately after 2 minutes of the program
end. This time delay is caused by the PTC which is
assambled in the door lock.

Figure 1. Door lock

Technical features :
Lock Time (20 C)
Unlock Time (20 C)
Nominal voltage
Nominal current

2 6
35 75
250 V
16 (4) A

Checking of component :
Check the resistance value on the component with multimeter as shown in Figure2.
Resistance value on the PTC should be 1000 50%.

Figure 2. Checking the component

DRAIN PUMP
Drain pump is both a mechanical and elektrical component
which is used to drain water inside the washing machine. It
has an synchronous motor inside. For better performance
maintanance, pump filter should be cleaned regularly.

Figure 3. Drain pump

Technical features :
Nominal voltage
Nominal current
Nominal power
Frequency
Resistor (coil)
Water flow:
Thermal protector

230 V
0.2 A
30 W
50 Hz
170 (7%)
18 l/min(to 1 m height)
YES

Checking of component :
Check the resistance value on the component with multimeter as shown in Figure 4.
Resistance value should be between 140- 200 Ohm

Figure 4. Checking the component

NTC
Component which sends signals to PCB about the water temperature inside
the tub. The Resistance (Ohm) value of the NTC decreases as the
temperature increases.

Figure 5. NTC

Techinal Feature :

Tem (C) R nom () R min () R max () R (+/- %)


-10,00
58.722,00 54.874,00 62.570,00
6,60
- 5,00
45.778,00 42.961,00 48.596,00
6,20
0,00
35.975,00 33.900,00 38.050,00
5,80
5,00
28.516,00 26.977,00 30.055,00
5,40
10,00
22.763,00 21.616,00 23.910,00
5,00
15,00
18.279,00 17.421,00 19.137,00
4,70
20,00
14.772,00 14.128,00 15.417,00
4,40
25,00
11.981,00 11.497,00 12.464,00
4,00
30,00
9.786,00
9.421,00 10.150,00
3,70
35,00
8.047,00
7.772,00
8.322,00
3,40
40,00
6.653,00
6.444,00
6.861,00
3,10
45,00
5.523,00
5.365,00
5.680,00
2,80
50,00
4.608,00
4.489,00
4.726,00
2,60
55,00
3.856,00
3.767,00
3.945,00
2,30
60,00
3.243,00
3.178,00
3.308,00
2,00
65,00
2.744,00
2.681,00
2.808,00
2,30
70,00
2.332,00
2.273,00
2.392,00
2,50
75,00
1.990,00
1.934,00
2.045,00
2,80
80,00
1.704,00
1.653,00
1.755,00
3,00
85,00
1.464,00
1.416,00
1.511,00
3,20
90,00
1.262,00
1.218,00
1.305,00
3,40
95,00
1.093,00
1.053,00
1.133,00
3,70
100,00
949,90
913,20
986,60
3,90
Table 1 .NTC Tempure Resistance Values

Checking of component :
Check the resistance value on the component with multimeter as shown in Figure 6.

Figure 6. Checking the component

EMI FILTER
EMI Filter Functions:
1. To adjust the frequency changes to the value of 50-60 Hz
which is the nominal frequency for the components.
2. To prevent harmonic frequency feedback sent by motor ,
resistance to the the network.

Figure 7. EMI Filter

Technical features :
Rated Voltage
Rated Current
Cx
Cy
L
R

250 V
16 A
0,47 F (20%)
2 x 25 nF (20%)
2 x 1 mH (+%50,-%30)
680 k (10%)

Checking of component :
Check the resistance value on the component with multimeter as shown in Figure 8.
Resistance value on the EMI filter (between L-N polars) should be 680 kohm (10%).

Figure 8. Checking the component


8

PRESSURE SWITCH
Voltage
Amper

: 250 V
:16 A

Figure 9. Pressure switch


Pressure switch is the component which regulates the water intake according to the water levels set
inside. The component is operated by PCB card. It has four connections : Reset, set, common,
overflow.

Technical features :
The component has three levels. When the component is at reset level, the machine begins to take
water inside. When the component is at set level, the machine stops to take water inside by
communicating with PCB card. The third level, overflow level, is set to prevent taking excessive
water(overflow) into the machine.
The pressure switches that have different water set levels have different water intake values
accordingly.

Checking of component :
1 ) Blow into the pressure switch hose or pressure switch entry. Be sure that you hear the switch click.
2 ) Turn the program adjustment knob rinse mode and let the machine take water in. Be sure that you
hear the switch click or the machine stops to take water inside after a while. (Figure 10.)

Figure 10. Program knob

RESISTANCE

Heating element (Resistance) is a component which is


desingned to regulate temperature of water inside the
drum. It has three connections: Phase, notral and ground
connections.

Figure 11. Resistance

Technical features :
Kind of heating
Nominal voltage
Nominal power
Resistance
Thermal fuse

Tubular heating element with NTC sensor


230 V
1850 W (5%)
26.96-29.80
2 sided

Checking of component :
Check the resistance value on the component with multimeter as shown in Figure 12.
Resistance value should be between 25- 30 Ohm.

Figure 12. Checking the component

10

VALVE
Valve is an electrical and mechanical component which is
designed to take water from the network system into the washine
machine. It is operated by PCB card.

Figure 13. Valve

Technical features :
Nominal voltage
Nominal power
Frequency
Rated flow:
Operating water pressure

220 240 V
8 VA
50 Hz
6 1/min (15%) (for cold inlet)
5.5 1/min (15%) (for hot inlet)
0.2 10 bar

Checking of component :
Check the resistance value on the component with multimeter as shown in Figure 14.
Valve water flow rate should be between 6 - 8 lt/min.
Each valve bobbin resistance values should be between 3 - 4.5 k .

Figure 14. Checking the component

11

MOTOR
The washing machine has an asynchronous
motor. It is controlled by the PCB.
It is essential to check the motor for correct
diagnosis and quick servicing. In the below picture,
socket points on the motor is shown to measure with
multimeter.

Figure 15. Motor

Tacho socket
terminal

Rotor coil
socket
terminal

Stator coil
socket
terminal

Tapped filled
coil socket
terminal

Figure 16. Motor socket terminals

12

Earthing

Tacho and stator (full field-half field) ohm resistance values for the motor types are listed in the below table.

MOTOR
CODE

SUPPLIER

STATOR (FULL
FIELD) (ohm)

TACHO
(ohm)

STATOR (HALF
FIELD) (ohm)

30027193

ANAIMEP

1.87-/+7%

180 -/+10%

20 C

30023397

ANAIMEP

1.75-/+7%

180 -/+10%

20 C

32002064

ANAIMEP

2.01-/+7%

180 -/+7%

20 C

32003425

ANAIMEP

2.01-/+7%

180 -/+7%

20 C

32000536

CESET

1.01 -/+7%

68.7-/+7%

20 C

32000271

CESET

1.40 -/+7%

68.7-/+7%

32000535

CESET

1.24 -/+7%

68.7-/+7%

32000537

CESET

1.34 -/+7%

68.7-/+7%

32002064

WELLING

2.08 -/+7%

66.6 -/+7%

20 C

32003425

WELLING

1.59 -/+7%

66.6 -/+7%

20 C

32004572

ACC

1.20 -/+7%

184 -/+10%

32004968

ATB

1.63-/+7%

90 -/+12%

32004969

ATB

1.57-/+7%

90 -/+12%

32004970

ATB

1.57-/+7%

90 -/+12%

0.56 -/+7%

Check the motor tacho terminals on the


motor socket with multimeter as shown in the
picture. For resistance values, refer to the table 1.

13

20 C
20 C

0.56 -/+7%

0.60 -/+7%

20 C

20 C
20 C

0.80 -/+7%

Table 2. Resistance values for the motor types

Tacho resistance control

TEMPERATURE

20 C
20 C

Stator Full Field Resistance Control

Check the motor stator terminals on the


motor socket with multimeter as shown in the
picture. For resistance values, refer to the table 1.

Stator Half Field Resistance Control

Check the motor stator terminals on the


motor socket with multimeter as shown in the
picture. For resistance values, refer to the table 1.

Operating the motor manually


In order to check the motor operation, it is operated manually by supplying input electricity.
The motor operation s should be checked by supplying energy for a short time. In the below pictures,
the checking operation is demonstrated.
Connect the rotor coil terminal and stator coil terminal with a conductive wire.

-W Tf-

-W0 Tf-

14

Connect one of the wires on the power cable with other rotor coil terminal.

-W Tf-

-W0 Tf-

Connect the other wire on the power cable with other stator coil terminal.

-W Tf-

-W0 Tf-

Note: The motor must be earthed by the


earth cable as shown in the picture.

15

Plug the power cable. (220 V 50 Hz). After


checking the motor operation, unplug the power
cable soonest.

(Please do not plug the power cable more than


15 seconds. )

ELECTRONIC CARD

Electronic card (PCB) is the control department of the washing machine. PCB gets and
sends signals to electrical components. All the program software is loaded in PCB.

16

ENERGY LABEL

LOGO:XXXXXX
MODEL:XXXXX
ENERGY PERFORMANCE
A
ENERGY CONSUMPTION
5
6
7
7,5

KG
KG
KG
KG

: 0,95 kWh/program
: 1,14 kWh/program
: 1,33 kWh/program
: 1,42 kWh/program

WASHING PERFORMANCE
A
SPINNING PERFORMANCE
600 RPM
800 RPM
1000 RPM
1200 RPM
1400 RPM
1600 RPM

:E
:D
:C
:B
:B
:A

CAPACITY
5 KG
6 KG
7 KG
7,5 KG
WATER CONSUMPTION
5 KG
6 KG
7 KG
7,5 KG

:
:
:
:

43 lt
49 lt
62 lt
63 lt

17

NAME PLATE

0000

18

SERVICE INDEX
NUMBER

Failure Codes
FAILURE CODE 1

A- Failure indicator situations

19

C- Error flowcharts

20

FAILURE CODE 2

A- Failure indicator situations

21

C- Error flowcharts

22

FAILURE CODE 3

A- Failure indicator situations

23

C- Error flowcharts

24

FAILURE CODE 4

A- Failure indicator situations

25

C- Error flowcharts

26

FAILURE CODE 5

B- Failure indicator situations

27

C- Error flowcharts

28

FAILURE CODE 6

A- Failure indicator situations

29

C- Error flowcharts

30

FAILURE CODE 7

A- Failure indicator situations

31

C- Error flowcharts

32

FAILURE CODE 8

A- Failure indicator situations

33

C- Error flowcharts

34

FAILURE CODE 9

A- Failure indicator situations

35

C- Error flowcharts

36

37

Auto Test Chart

DETERGENT BOX GROUP WORK PRINCIPLE


MAIN

SOFTENER

VALVE 1

PREWASH

VALVE 2

PREWASH = WATER ENTRY VALVE 1


MAIN
= WATER ENTRY VALVE 2
SOFTENER = WATER ENTRY VALVE 1 + VALVE 2

38

CHILD LOCK MANUAL


Press the first and second function button for 3-4 seconds to activate child lock.

Wash, rinse and spin LEDs will flash for 2 seconds.

39

Wash, rinse and spin LEDs will flash for 2 seconds, if any button is pressed on the
control panel.

Press the first and second function button for 3-4 seconds to inactivate child lock.

40

End LED will be on for 2 seconds.

41

AUTOTEST MANUAL
1) Press the 1st Function button when the Program knob is at the STOP position.

2) While pressing 1st Fuction button. Change the position of the knob to 1.

42