Sei sulla pagina 1di 29

Product Documentation

Rev.Date

2009-09-28

Prepared by

HRS

Rev.

Document ID
Approved by

NGP\00654

Evolution Series EDGE


Configuration Guide

1.

INTRODUCTION...............................................................................................................................3

2.
2.1
2.1.1
2.2

UNIT DESCRIPTIONS......................................................................................................................3
IFU.....................................................................................................................................................3
SD Memory Card (support from SW release 2) ................................................................................3
ODU ..................................................................................................................................................3

3.

LINK CONFIGURATIONS ................................................................................................................5

4.
4.1
4.2
4.3
4.4
4.5
4.6
4.6.1
4.6.2

LICENCES ........................................................................................................................................5
Capacity ............................................................................................................................................5
Adaptive Coded Modulation..............................................................................................................5
NMS encryption.................................................................................................................................5
E1s ....................................................................................................................................................6
E1Cross-Connect (PXC) .................................................................................................................6
ETHERNET features.........................................................................................................................6
VLAN .................................................................................................................................................6
RSTP.................................................................................................................................................6

5.
5.1
5.2
5.3
5.4
5.5
5.5.1
5.5.2
5.6
5.6.1
5.6.2
5.7
5.8
5.9
5.10
5.10.1

INSTALLATION MATERIAL .............................................................................................................7


IFU Mounting kit ................................................................................................................................7
Power cable ......................................................................................................................................7
Grounding Kit ....................................................................................................................................7
Lightening protection.........................................................................................................................8
Data cables .......................................................................................................................................9
Data cables for ETHERNET and EBUS interfaces...........................................................................9
Data cables for E1 interfaces............................................................................................................9
ODU Mounting Material ..................................................................................................................10
Pole Mount kit with WG adapter .....................................................................................................11
Flexible WG and Coax kits..............................................................................................................12
Rack frame & accessories ..............................................................................................................13
Power distribution............................................................................................................................14
E1 Patch Panels..............................................................................................................................15
IFU-ODU Cables .............................................................................................................................16
IFU-ODU Jumper Cable..................................................................................................................16

6.

ANTENNAS.....................................................................................................................................16

7.

CONFIGURATION EXAMPLES ETHERNET ..............................................................................17

8.

CONFIGURATION EXAMPLES ETHERNET & E1 .....................................................................21

9.
9.1
9.2

CONFIGURATION EXAMPLES HOT STANDBY........................................................................25


HSB Equipment Protection System (EPS) ..................................................................................25
HSB Radio Protection System (RPS) ..........................................................................................26

10.

INTERCONNECTION XPAND/METRO EDGE ...........................................................................27

11.

INTERCONNECTION XPAND/METRO EDGE USING PATCH PANEL.....................................28

12.

E1 ACCESS THROUGH PATCH PANELS ....................................................................................29

Nera Networks

Page 1(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 7-1 Single Link configuration (1+0) ......................................................................................................................17


Figure 7-2 Repeater (1+0) with add/drop of Ethernet-traffic ............................................................................................18
Figure 7-3 Spur Site Ethernet connections.....................................................................................................................19
Figure 7-4 Ring Configuration Ethernet connections ....................................................................................................20
Figure 8-1 Ethernet & E1, 1+0 Link .................................................................................................................................21
Figure 8-2 Ethernet & E1, 1+0 Repeater...........................................................................................................................22
Figure 8-3 E1 & Ethernet Spur Site (1+0) .....................................................................................................................23
Figure 8-4 E1 & Ethernet in a ring configuration (1+0) ...................................................................................................24
Figure 9-1 Hot Standby EPS principal block diagram ...................................................................................................25
Figure 9-2 Hot Standby RPS principal diagram.............................................................................................................26
Figure 10-1 XPAND/METRO connection to EDGE - 1+0, or to EDGE RPS (ODU protection) .................................27
Figure 10-2 XPAND/METRO connection to EDGE EPS (IFU and ODU protection)..................................................27
Figure 11-1 XPAND/METRO connection to EDGE using patch panel (1+0 and HSB-RPS)..........................................28
Figure 11-2 XPAND/METRO connection to EDGE using patch panel (HSB-EPS)........................................................28
Figure 12-1 EDGE 1+0 - E1 access using patch panel (Coax, 75ohm or RJ45, 120ohm) ................................................29
Figure 12-2 EDGE HSB-EPS - E1 access using patch panel (Coax, 75ohm or RJ45, 120ohm) ......................................29

Page 2(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

1. INTRODUCTION
This document covers Evolution Series EDGE configurations

2. UNIT DESCRIPTIONS
2.1 IFU

IFU

FUBU6812A-T (Ethernet + 20E1 interface)

or

FUBU6812B-T (Ethernet only)

2.1.1 SD Memory Card (support from SW release 2)


The IFUs (from HW release 1) have a slot for an optional SD memory card. The memory card can be used for
configuration backup and storage of performance data. Standard SD or SDHC cards can be used
SD card offered by Nera:
o 2Gb card : TBD

2.2 ODU
The ODU consist of a XCVR and a diplexer. The XCVR is tuneable over the whole frequency band, both high and low
part. The diplexer determines subband range and high or low TX. For most bands and duplex spacings four ODUs
codes are defined. The EDGE XCVRs are not compatible with other XCVRs in the Evolution family. Diplexers,
Antennas and Grounding Kits are common for EDGE, XPAND and METRO.
ODUs from 7-38 GHz can be mounted directly to single polarised antennas up to 180 cm / 6 ft.

Page 3(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

HSB or 2+0 (DF-SP) Configurations


Two ODUs and RF Coupler
The ODUs must be in the same sub-band

NGP\00654

1+0 Configuration

ODU coverage example.


ODU Article Code : FU08ADC0A-suffix (the D in the middle indicates EDGE-ODU)
Duplex spacing : 300/310/311.32 MHz
Subband

ODU
suffix
TX-low

-11LA

-12LA

Low sub-band
passband
7718 7851

High sub-band
passband
8025 8163

7822 - 7971

ODU
suffix
TX-high
-11UA

8133 - 8282

-12UA

Page 4(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

3. LINK CONFIGURATIONS
The following link configurations are available.
Description

Configuration
1+0

Non-protected

1+1 HSB EPS

IFU and ODU protected. External switches used for


Ethernet switching and Y-cable used for E1 split

1+1 HSB RPS

ODU protected. Internal switch used for Ethernet switching


and E1-switching. Customer connection to one IFU only
Table 3-1 Link Configurations

4. LICENCES
Evolution Series EDGE has two types of licences; Transmission Capacity/Adaptive Modulation and Features. The
licenses are stored in the IFU. All licenses are SW based and none of them requires additional hardware. HSB
configurations require one license per IFU (double set of licenses).

4.1 Capacity
A licence is required to enable 16 and 32 QAM modulation (max 100 Mbps Ethernet and max link capacity of 111
Mbps). Without this license or the ACM-license the system can only be configured with 4QAM modulation.

16 and 32 QAM license for max capacity

EVLIC-EDGE-C100

Link Capacity vs. channel BW


Modulation

7 MHz

14 MHz

28 MHz

4QAM (no license)

10.5 Mb/s (0-5 E1)

21 Mb/s (0-10 E1)

44 Mb/s (0-20 E1)

16QAM (license)

21 Mb/s (0-10 E1)

44 Mb/s (0-20 E1)

89 Mb/s (0-20 E1)

32QAM (license)

27 Mb/s (0-12 E1)

56 Mb/s (0-20 E1)

111 Mb/s (0-20 E1)

4.2 Adaptive Coded Modulation


A license is required to enable Adaptive Coded Modulation. This license supersedes the C100 license (above) and will
in addition enable the adaptive change of modulation based in received SNR.

ACM license

EVLIC-EDGE-ACM

4.3 NMS encryption


This license enables SSL encryption and the SNMPv3 protocol on the communication between the network element and
the computer (manager).

Encrypted management traffic

EVLIC-EDGE-NMSENC

Page 5(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

4.4 E1s
Two alternative licenses are available to enable E1 traffic over the radio-interface (air). Without a PXC license the E1s
will automatically be routed to the E1-front-ports.

License for 1-5 E1s


License for 1-20 E1s

EVLIC-EDGE-5E1T1
EVLIC-EDGE-20E1T1

4.5 E1Cross-Connect (PXC)


A license is available to enable the built-in 4-port E1 cross-connect. With a PXC license you can configure E1 to E1,
E1 to EBUS1, E1 to EBUS2 and E1s in EBUS1 to E1s in EBUS2.
Combined with an E1 license you can also configure the E1s to use the radio-port of the PXC.

PXC License.

EVLIC-EDGE-PXC

4.6 ETHERNET features


Ethernet QoS is standard and does not require any license.

4.6.1 VLAN
This license is used to enable configuration and switching based on VLAN-ID.

VLAN switching license

EVLIC-EDGE-VLANSW

4.6.2 RSTP
This license is used to enable the RST Protocol to avoid Ethernet loops in the network.

RSTP license

EVLIC-EDGE-RSTP

Page 6(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

5. INSTALLATION MATERIAL
5.1 IFU Mounting kit
The IFU Mounting kit contains mounting-frame for up to two IFUs (1RU), 1 blind panel and screws for the blind panel
and 4 rack screws.

IFU mounting Kit:

ABZ6814

5.2 Power cable


Code: 88W5362-PWR10000
Power cable, 10m (one cable per IFU). One end has a
male power-connector mounted (matching the IFU). The
other end is open.

5.3 Grounding Kit


The grounding kit contains IFU grounding cable 4mm2, 2.5m and ODU grounding cable 10mm2, 2.5m. One kit per
IFU/ODU.

IFU and ODU grounding kit

UWA6462

Page 7(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

5.4 Lightening protection


The EDGE IFU and ODU have built-in lightening protection, but in areas with heavy lightening we recommend to add
additional protection by introducing a lightening arrestor on the IFU-ODU cable. This arrestor should be installed at the
entrance to a cabinet or shelter and be properly grounded. An additional arrestor may also be installed close to the
ODU.
Code: BGXZ-60TFTN-CSN
Water-proof lightening arrestor with TNCfemale connectors. Includes HW Kit for
mounting:

Code: 9100-0454
ODU mounting kit for lightening arrestor.
Use:
o

To be used when mounting the


lightening arrestor on a pole close to
the ODU.

Page 8(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

5.5 Data cables


5.5.1 Data cables for ETHERNET and EBUS interfaces
Cat5, STP cables with 8P8C male termination (Tyco/AMP) in both ends. (1/2 crossed with 3/6 and 4/5 crossed with
7/8)
88W5361-MULT400
Crossover cable, 40 cm, 100 ohm
88W5361-MULT1000
Crossover cable, 1 m, 100 ohm
88W5361-MULT3000
Crossover cable, 3 m, 100 ohm
88W5361-MULT5000
Crossover cable, 5 m, 100 ohm
RJ-45 male-connector in both ends.
Use:
1. LAN connections to external equipment
2. LAN connections to other Evolution IFUs
3. EDGE EBUS-EBUS connections.
88W5363-MULT400
ETH4 adapter cable, 40 cm, 100ohm.
RJ-45 male-connector in one end and RJ-45 female connector in
other end.
Use:
o
Tip:
o

ETH4 adapter cable from proprietary pinout to standard


pinout. Pin 4&5 mapped to pin 1&2, and pin 7&8 mapped
to pin 3&6.
Use 88W5361-MULT<xxxx> to extend length

5.5.2 Data cables for E1 interfaces


Cables with an 8P8C male termination (Tyco/AMP) in both ends. For detailed wiring, please see the Evolution Series
EDGE User Manual:
88W5371-MULT400
88W5371-MULT5000
88W5371-MULT10000
88W5371-MULT15000
Use:
o
Tip:
o

E1 connection from IFU to external equipment. Standard


pinning for E1#1. Proprietary pinning for E1#2.
Use 88W5370-MULT500 to split the 2xE1 to 2 x standard
E1s if 2xE1 per IFU-port is used

88W5360-MULT400
88W5360-MULT5000
88W5360-MULT10000
88W5360-MULT15000
Use:
o

E1 straight-thru cable, 40 cm, 120 ohm


E1 straight-thru cable, 5 m, 120 ohm
E1 straight-thru cable, 10 m, 120 ohm
E1 straight-thru cable, 15 m, 120 ohm

E1 crossover cable, 40 cm, 120 ohm


E1 crossover cable, 5 m, 120 ohm
E1 crossover cable, 10 m, 120 ohm
E1 crossover cable, 15 m, 120 ohm

E1 connections between EDGE IFUs. This is not needed


when EBUS connections are available.

Page 9(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

88W5370-MULT500
Use:
o
Tip:
o

Tip:

o
o

Combine with 88W5352-MULT500 or 88W5353 if EDGE


configuration HSB-EPS is used

E1 Y-cable, 50 cm, 120 ohm

Used in HSB-EPS configuration to split E1s to both IFUs.


(2xE1 on the female connector same pinning as IFUfront)

E1 Y-cable with split, 50 cm, 120 ohm

Used in HSB-EPS configuration to split E1s to both IFUs.


(1xE1 on each of the 2 female connectors same pinning
as IFU-front E1#1)

UWMK6706
Use:
o

E1 patch cable, 2 m, 120 ohm

Evolution male multi-connector to EDGE 8P8C male


termination. 1 or 2 x E1 per RJ-45 as configured.
Maximum 12xE1 per patch cable.
75 ohm Patch Panel 88B5328 to EDGE IFU

88W5353-MULT500
Use:
o

E1 split cable, 50 cm, 120 ohm

Use 88W5360-MULT<xxxx> or 88W5371-MULT<xxxx>


to extend length

88W5352-MULT500
Use:
o

NGP\00654

E1 split cable. 1x8P8C male to 2x8P8C female. Use to


split the two E1s from an IFU-port to two standard E1s

88W5354-MULT2000
Use:
o

Document ID

A
Evolution Series EDGE

Patch cable 2 m / 6.6 ft / crossover:

To be used with the patch panels to connect from Evolution


E1-multiconnector (XPAND/METRO) to back side of
patch panel (12 E1s per cable)

5.6 ODU Mounting Material


The ODU can be mounted directly to the antenna.

Page 10(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

5.6.1 Pole Mount kit with WG adapter


It is recommended to use the pole mount kit with WG adapter. The Flex-WG is then mounted to the adapter and not
directly to the ODU or Coupler. The advantage is that the ODU can be removed without removing the Flex-WG.

Article

Interface

Frequency

RMT-PDR70-NR3

PDR 70

6 GHz

RMT-PBR84-NR3

PBR 84

7/8 GHz

RMT-PBR100-NR3

PBR 100

10/11GHz

RMT-PBR120-NR3

PBR 120

13 GHz

RMT-PBR140-NR3

PBR 140

15 GHz

RMT-PBR220-NR3

PBR 220

18/23/26 GHz

RMT-PBR320-NR3

PBR 320

28/32/38 GHz

Page 11(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

5.6.2 Flexible WG and Coax kits


All Flexible WG kits include gaskets plus two sets of short and two sets of long flange screws.
(Both short and long for both ends). They have tin-plated flanges at both ends. They fit both against Brass and
Aluminium flanges. Cable ties are included with each kit L=368 mm
Article Number
FLXT1000-PDR70PDR-T-1

ODU
Frequency
6 GHz

ODU
WG-flange
PBR70

Antenna
WG-Flange
PDR70

FLXT1000-PBR84PDR-T-1

7 and 8 GHz

PBR84

PDR84

FLXT1000-PBR84PBR-T-1

7 and 8 GHz

PBR84

PBR84

FLXT1000-PBR100PBR-T-1

11 GHz

PBR100

PBR100

FLXT1000-PBR100PDR-T-1

11 GHz

PBR100

PDR100

FLXT900-PBR120PBR-T-1

13 GHz

PBR120

PBR120

FLXT900-PBR120PDR-T-1

13 GHz

PBR120

PDR120

FLXT900-PBR140PBR-T-1

15 GHz

PBR140

PBR140

FLXT900-PBR140PDR-T-1

15 GHz

PBR140

PDR140

FLXT900-PBR220PBR-T-1

18 - 26 GHz

PBR220

PBR220

FLXT900-UBR220UBR-T-1

18 - 26 GHz

UBR220

UBR220

FLXT600-PBR320PBR-T-1

28 -38 GHz

PBR320

PBR320

Length
1000
3.3 ft
1000
3.3 ft
1000
3.3 ft
1000
3.3 ft
1000
3.3 ft
900 mm
3 ft
900 mm
3 ft
900 mm
3 ft
900 mm
3 ft
900 mm
3 ft
900 mm
3 ft
600 mm
2 ft

Page 12(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

5.7 Rack frame & accessories


A basic rack frame and accessory kits are available.

Rack Frame

The rack frame is available in two


heights. Flat packed version available
Q4-2009
210 cm / 7 ft high, max 10 XCVRs

97B5284A-1

170 cm / 5.6 ft high, max 8 XCVRs

97B5284A-2

210 cm / 7 ft high, max 10 XCVRs


Flat packed

ABW6886-2092

170 cm / 5.6 ft high, max 8 XCVRs


Flat packed

ABW6886-1692

Screw and Bracket Kit

MSK5371

Support Bar

MJK46

Includes items for fixing the rack to the


floor or to the support bar.
Coach screws w/plastic plugs
Brackets for Support bar

225 mm long

Rack Installation kit

ABZ6478

Rack to wall/ceiling brackets including


support for ODU jumper cable
Earthing bar
4 adjustable feet
Cage nuts (50)
Cable ties (20)
Rack grounding cable (station earth)
2.5m 10 mm2
Rack top grounding cable
20 cm 6mm2

Page 13(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

5.8 Power distribution


Power distribution with circuit breakers is available as an option.

Power distribution

UWC6709-04

2 main switches and 4 secondary


switches/circuit breakers, earth terminals,
DIN rail, brackets and front panel

2 main switches and 11 secondary


switches/circuit breakers, earth terminals,
DIN rail, brackets and front panel.

UWC6709-11

Page 14(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

5.9 E1 Patch Panels


Patch panel for interfacing between Evolution multi-connector and
Evolution EDGE E1 connectors (RJ-45). Patch cable UWMK6706
must be used between the XPAND/METRO E1-Unit and the Panel.
Between the Panel and the Edge IFU you can use the 88W5360MULTxxxx cables (E1-crossover)
88B5328-K260

Front
Back

88B5328-K244
88B5328-K245
88B5328-K246
88B5328-K247
88B5328-K255
88B5328-K257

12xE1, BNC connectors


25xE1, BNC connectors
12xE1, 1.0/2.3 connectors
25xE1, 1.0/2.3 connectors
25xT1/E1 RJ45 connectors.
25xT1/E1 IDC (Krone)
connectors.

Patch panel with conversion from 120 ohm to coaxial 75 ohm. Patch
cable 88W5354-MULT2000 must be used between IFU Unit and the
Panel

Single baluns and panel is an alternative if the number of E1s is low. The standard E1 cable is used between the E1 Unit
and the balun.
97B5323B-1
97B5323B-2A
97B5323B-3

25xE1,for 1.6/5.6 baluns


23xE1, for BNC baluns
25xE1, for 1.0/2.3 baluns

87T33-3A

Balun with 1.0/2.3 connector

87T33-1C

Balun with 1.6/5.6 connector

87T33-2C

Balun with BNC connector

Page 15(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

5.10 IFU-ODU Cables


Maximum cable length between IFU and ODU is 200m/650ft.
CNT-400 Cable
100 m/328 ft Cable and ties
200 m/656 ft Cable and ties
500 m/1640 ft.cable reel
Cable ties, Pack of 50.
Connectors & grounding kit, CNT-400

UWMH6506-100
UWMH6506-200
AN-CNT-400-500M
AN-40417
UWA6510

5.10.1 IFU-ODU Jumper Cable


IFU-ODU Jumper Cable 2.5 m / 8.2 ft

UWMH6475

It is highly recommended to use jumper cable between IFU and IFU ODU main cable.
The cable has one female and one male connector.

6. ANTENNAS
Two types of integrated antennas are available. The Low Profile Series and the BaseLine Series.
Antennas in the Low Profile Series comply with ETSI RPE class 3 specification.
Antennas in the BaseLine Series comply with ETSI RPE class 2 specification.

Low Profile Series antenna

BaseLine Series antenna

Page 16(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

7. CONFIGURATION EXAMPLES ETHERNET

Figure 7-1 Single Link configuration (1+0)


Configuration hints and options:
o Use adapter cable 88W5363-MULT400 to get access to ETH4
o NMS and User Traffic are separated when using the factory default configuration (as shown above)
o In MAC-switching mode, NMS and user traffic is mixed, and can be connected to any port
o VLAN-license gives full flexibility to configure NMS and User Traffic to any port
Mandatory licenses:
o None
o
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
o RSTP license is needed if there is more than one connection to one external unit not supporting RSTP
Cables:
o ETH1-4:

4x 88W5361-MULT<XXXX> (ETH1 is NMS connection)

Page 17(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 7-2 Repeater (1+0) with add/drop of Ethernet-traffic


Configuration hints and options:
o The example shows ETH4 (using an EBUS-cable) used to interconnect the IFUs. ETH2 or ETH3 may also be
used for interconnection of IFUs, but management traffic does not go on ETH2 and ETH3 in default mode
o NMS connection locally is optional. Local management connection to one IFU will also provide access to the
2nd IFU (through ETH4)
o NMS and User Traffic are separated when using the factory default configuration (as shown above)
o In MAC-switching mode, NMS and user traffic is mixed, and can be connected to any port
o VLAN-license gives full flexibility to configure NMS and User Traffic to any port
Mandatory licenses:
o None
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
o RSTP license is needed if there is more than one connection to one external unit not supporting RSTP
Cables:
o ETH1-4:

4x 88W5361-MULT<XXXX> (ETH1 is NMS connection)

Page 18(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 7-3 Spur Site Ethernet connections

Configuration hints and options:


o The example shows EBUS1 used to interconnect node A & B (Management- and User- traffic)
o Management traffic between node A to C goes through ETH1
o Ethernet traffic from node A to C goes through ETH3
o Traffic (Management and User traffic) from node B to C is going through node A. A redundant connection
may be established between node B and C (requires RSTP license to avoid Ethernet loops)
o Two cables between node A and C is necessary to keep management traffic separated from user traffic. In
MAC-switching mode or with VLAN licenses activated, one cable is sufficient between node A & C
Mandatory licenses:
o None
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
o RSTP license is needed if there is more than one connection to one external unit not supporting RSTP or if a
redundant Ethernet connection is established between node B and C.
Cables:
o ETH1-4:

4x 88W5361-MULT<XXXX> (ETH1 is NMS connection)

Page 19(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 7-4 Ring Configuration Ethernet connections

Configuration hints and options:


o The example shows ETH4 used to interconnect the IFUs
o It may be wise to avoid using ETH1 for user-traffic to have the port available for management connections
during site visits
o Bridge priority should be modified from default-value to select root bride in the Ethernet-ring (optimization of
RSTP loop break-point)
Mandatory licenses:
o RSTP license is needed on all IFUs to avoid Ethernet loops (available from R2)
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
Cables:
o ETH1-4:

4x 88W5361-MULT<XXXX> (ETH1 is NMS connection)

Page 20(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

8. CONFIGURATION EXAMPLES ETHERNET & E1

Figure 8-1 Ethernet & E1, 1+0 Link


Configuration hints and options:
o Use adapter cable 88W5363-MULT400 to get access to ETH4
o Configurations with < 10xE1 is using one 1xE1 per interface to allow simpler interconnection to external
equipment (no split cable is needed)
o NMS and User Traffic are separated when using the factory default configuration (as shown above)
o In MAC-switching mode, NMS and Ethernet traffic is mixed, and can be connected to any port
o VLAN-license gives full flexibility to configure NMS and Ethernet traffic to any port
Mandatory licenses:
o E1 license is required to enable E1 over the air
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
o RSTP license is needed if there is more than one connection to one external unit not supporting RSTP
o PXC license is not required unless PXC functionality is desired on a specific terminal. One link can have PXC
license activated on one terminal or both terminals as desired
Cables:
o ETH1-3:
1-3x 88W5361-MULT<XXXX> (ETH1 is NMS connection)
o ETH4:
1x 88W5363-MULT400 + 1x 88W5361-MULT<XXXX>
o E1 options:
88W5371-MULT<XXX>
Used for connection to external equipment (one E1 per cable)
88W5370-MULT500
Used to split to 2xE1. Use 88W5371-MULT<XXXX> to extend length

Page 21(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 8-2 Ethernet & E1, 1+0 Repeater


Configuration hints and options:
o Unused E1 & ETH-ports should be disabled to avoid unnecessary alarms
o Configurations with < 10xE1 is using one 1xE1 per interface to allow simpler interconnection to external
equipment (no split cable is needed)
o NMS and User Traffic are separated when using the factory default configuration (NMS on ETH1)
o In MAC-switching mode, NMS and Ethernet traffic is mixed, and can be connected to any port
o VLAN-license gives full flexibility to configure NMS and Ethernet traffic to any port
Mandatory licenses:
o E1 license is required to enable E1 over the air
o PXC license is required to enable E1 cross-connected into EBUS1 and/or EBUS2
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
o RSTP license is needed if there is more than one connection to one external unit not supporting RSTP
Cables:
o ETH1-3:
1-3x 88W5361-MULT<XXXX> (ETH1 is NMS connection)
o ETH4:
1x 88W5363-MULT400 + 1x 88W5361-MULT<XXXX>
o E1 options:
88W5371-MULT<XXX>
Used for connection to external equipment (one E1 per cable)
88W5370-MULT500
Used to split to 2xE1. Use 88W5371-MULT<XXXX> to extend length

Page 22(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 8-3 E1 & Ethernet Spur Site (1+0)


Configuration hints and options:
o Configurations with < 10xE1 is using one 1xE1 per interface to allow simpler interconnection to external
equipment (no split cable is needed)
o The example shows EBUS1 used to interconnect node A & B (Management- and User- traffic)
o Management traffic between node A to C goes through ETH1
o Ethernet traffic from node A to C goes through ETH3
o Traffic (Management and User traffic) from node B to C is going through node A. A redundant connection
may be established between node B and C (requires RSTP license to avoid Ethernet loops)
o Two cables between node A and C is necessary to keep management traffic separated from user traffic. In
MAC-switching mode or with VLAN licenses activated, one cable is sufficient between node A & C
Mandatory licenses:
o E1 license is required to enable E1 over the air (one license per IFU in the relevant link)
o PXC license is required to enable E1 cross-connected into EBUS1 and/or EBUS2
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
o RSTP license is needed if there is more than one connection to one external unit not supporting RSTP
Cables:
o ETH1-3 & EBUS:
88W5361-MULT<XXXX>
(<XXXX> is the length in mm)
o E1s:
88W5371-MULT<XXX>
Used for connection to external equipment (one E1 per cable)
88W5370-MULT500
Used to split to 2xE1. Use 88W5371-MULT<XXXX> to connect
to 88W5370-MULT500
88W5360-MULT<XXXX>
Used for direct E1 connection between IFUs (not EBUS)

Page 23(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

Figure 8-4 E1 & Ethernet in a ring configuration (1+0)


Configuration hints and options:
o The example shows ETH4 used to interconnect the IFUs
o It may be wise to avoid using ETH1 for user-traffic to have the port available for management connections
during site visits
o Bridge priority should be modified from default-value to select root bride in the Ethernet-ring (optimization of
RSTP loop break-point)
Mandatory licenses:
o E1 license is required to enable E1 over the air
o PXC license is required to enable E1 cross-connected into EBUS1 and/or EBUS2
o RSTP license is needed on all IFUs to avoid Ethernet loops (available from R2)
Optional licenses:
o Capacity (C100) or ACM license is needed to use higher modulation than 4QAM
o VLAN license to be included if VLAN partitioning is planned
Cables:
o ETH1-3 & EBUS:
88W5361-MULT<XXXX>
(<XXXX> is the length in mm)
o E1s:
88W5371-MULT<XXX>
Used for connection to external equipment (one E1 per cable)
88W5370-MULT500
Used to split to 2xE1. Use 88W5371-MULT<XXXX> to connect
to 88W5370-MULT500
(88W5360-MULT<XXXX>
Used for direct E1 connection between IFUs (not EBUS))
Warning:
o No ring protection of E1s

Page 24(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

9. CONFIGURATION EXAMPLES HOT STANDBY


9.1 HSB Equipment Protection System (EPS)

Figure 9-1 Hot Standby EPS principal block diagram


HSB EPS characteristics:
o Protected IFU and ODU
o Y-cables used for E1 split (1 or 2 E1 per cable)
o External split of LAN- and Management traffic (external switch with management and user data separated on
different ports)
o EBUS2 is used for control signals only
Mandatory licenses:
o None
Optional licenses:
o E1/Capacity/ACM/VLAN licenses as for 1+0. One license per IFU (Two licenses per HSB terminal)
o PXC- or RSTP- licenses are not needed for this configuration
Configuration alternatives:
o An integrated one antenna solution may be used by including a coupler. Using the coupler may require larger
antennas to compensate for the coupler losses
o EBUS1 may be used between IFUs instead of EBUS2 if ETH4 is disabled
o Two options exist for E1 Y-cable. One has two E1s on the female connector to external equipment, and the
other has a built in split to two female connectors (one E1 on each)
Cables:
o ETH1-3 & EBUS:
88W5361-MULT<XXXX>
(<XXXX> is the length in mm)
o E1 Y -cables:
88W5352-MULT500 or 88W5353-MULT500 (with split)
o E1 cable extension from the Y-cables as for 1+0 (see Figure 8-1 Ethernet & E1, 1+0 Link)

Page 25(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

9.2 HSB Radio Protection System (RPS)

Figure 9-2 Hot Standby RPS principal diagram


HSB RPS characteristics:
o Configuration is available from SW-Rel 2 (October 2009) (SW-upgrade)
o Protected ODU
o All user connections to Main IFU. Both Ethernet- and E1- traffic to Standby IFU goes the through EBUS1
cable
o Simplified cabling lower cost no external switch needed for Ethernet traffic
Mandatory licenses:
o None
Optional licenses:
o E1/Capacity/ACM/VLAN licenses as for 1+0. One license per IFU (Two licenses per HSB terminal)
o PXC- license is not required for any IFU
o RSTP- license is not needed for this configuration
Configuration alternatives:
o An integrated one antenna solution may be used by including a coupler. This solution may require larger
antennas to compensate for the coupler losses
Cables:
o ETH1-3 & EBUS:
88W5361-MULT<XXXX>
o E1 cables as for 1+0 (see Figure 8-1 Ethernet & E1, 1+0 Link)

(<XXXX> is the length in mm)

Page 26(29)

Product Documentation
Rev.Date

2009-09-28

Rev.

Document ID

A
Evolution Series EDGE

NGP\00654

10. INTERCONNECTION XPAND/METRO EDGE

&

Figure 10-1 XPAND/METRO connection to EDGE - 1+0, or to EDGE RPS (ODU protection)

"#$%

NMS/LAN: Include as many cables as needed to achieve the desired connectivity. Minimum is 1 cable if
NMS and Data are configured in MAC- or VLAN switching mode. Minimum 2 cables if NMS and User data
are configured on separate ports.
The E1 cable can carry up to 12 E1. Use two cables if more is needed.

&

Figure 10-2 XPAND/METRO connection to EDGE EPS (IFU and ODU protection)

Page 27(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

11. INTERCONNECTION XPAND/METRO EDGE USING PATCH PANEL

"#$%

&

"
#
$
%

&

Figure 11-1 XPAND/METRO connection to EDGE using patch panel (1+0 and HSB-RPS)

(
"! ! 6
26&
$ "! !"2

' 4
5&
"! ! 6" "2 "! ! 6
(

'

!1 2 !
))*+ ,
- .///0

))*+ ,
- .////0
/
$
:%
" "9
!1 2 ! 3 !1

* 7,8 ,
" "9 $ !1 :%
/ "2 :%
;
)/ "2 :%

!1 2 % " "9
"6 <.//////0

Figure 11-2 XPAND/METRO connection to EDGE using patch panel (HSB-EPS)

Page 28(29)

Product Documentation
Rev.Date

Rev.

2009-09-28

Document ID

A
Evolution Series EDGE

NGP\00654

12. E1 ACCESS THROUGH PATCH PANELS

"#$%

&

"
#
$
%

&

Figure 12-1 EDGE 1+0 - E1 access using patch panel (Coax, 75ohm or RJ45, 120ohm)

(
"! ! 6
26&
$ "! !"2

' 4
5&
"! ! 6" "2 "! ! 6
'

!1 2 !
))*+ ,
- .///0

))*+ ,
- .////0
/
$
:%
" "9
!1 2 ! 3 !1

!1 2 % " "9
"6 <.//////0

* 7,8 ,
$ !1 :%
/

* 7,8 ,
$ !1 :%
/

!1 2 %
"6 <)) + ) 7.///0

Figure 12-2 EDGE HSB-EPS - E1 access using patch panel (Coax, 75ohm or RJ45, 120ohm)