Sei sulla pagina 1di 2

13-19(F)/300 Water is heated in a copper tube of 1/D at a pt.

along the tube the average temp. is 100F and the tube wall temp.
Is 210F. Calculate the heat transfer coefficient and the heat flux for
a water velocity at 5 ft/s.

4.5-1(G)/240 Air at 206.8 kPa and an average of 477.6 K is being


treated as it flows through a tube of 25.4 mm inside diameter at a
velocity of 76.2 m/s. The heating medium is 488.7K steam
condensing at the outside of the tube. Since the heat transfer
coefficient of condensing steam is several thousand Wm2K and the
resistance of the metal wall is very small, it will be assumed that the
surface wall temperature of the metal in contact with air 488.7 K.
Calculate the heat transfer flux.

Calculate the rate of heat by convection of 2 sch 40 pipe at 120C


to the surrounding air at 30C. Express the answer n W/m length of
pipe. (horizontal arrangement)

Calculate the net interchange of radiation between a 2 sch 40


oxidized steel pipe at 120oC and a big room whose wall temperature
is 30oC.
13.20(F) /300 Air at atmospheric pressure and an average
temperature of 100F is flowing at 10,000ft3/min through a 3
circular duct. The wall temperature is 300F. Calculate the heat flux.

13.20(F) /300 Air at atmospheric pressure and an average


temperature of 100F is flowing at 10,000ft3/min through a 3
circular duct. The wall temperature is 300F. Calculate the heat flux.

Determine the net heat transfer by radiation bet. Two surfaces A &
B, expressed in Watts. If the temperature A & B are 700 K & 300 K,
respectively.
a) Surfaces A& B are infinitely parallel planes (stainless steel) of
b) Surfaces A is a 6mx2m oxidized aluminum plate & B is a
double row of staggered Cu pipe 4 cm in diameter, 2 m long
set on an 8 cm pitch.
c) Surfaces A & B are concentric oxidized steel pipes 10 cm and
12 cm in diameter respectively & 2 m long.
Paddle agitator w/ no baffles
a= 0.36, b=2/3, m=0.21, Nre= 300- 3x105
Flat blade turbine agitator w/ no baffles
a= 0.54, b=2/3, m=0.14, Nre= 30- 3x105
Flat blade turbine agitator w/ baffles
a= 0.74, b=2/3 m= 0.14, Nre= 500- 3x105
Anchor agitator w/ no baffles
a= 1.0, b= 1/2 , m= 0.18, Nre= 10-300
a= 0.36, b= , m= 0.18, Nre= 300- 4x104
Helical ribbon agitator w/ no baffles
a= 0.633, b= , m= 0.18, Nre= 8x105

Paddle agitator w/ no baffles


a= 0.36, b=2/3, m=0.21, Nre= 300- 3x105
Flat blade turbine agitator w/ no baffles
a= 0.54, b=2/3, m=0.14, Nre= 30- 3x105
Flat blade turbine agitator w/ baffles
a= 0.74, b=2/3 m= 0.14, Nre= 500- 3x105
Anchor agitator w/ no baffles
a= 1.0, b= 1/2 , m= 0.18, Nre= 10-300
a= 0.36, b= , m= 0.18, Nre= 300- 4x10 4
Helical ribbon agitator w/ no baffles
a= 0.633, b= , m= 0.18, Nre= 8x105
A jacketed vessel 1.83m diameter agitated vessel w/ baffles s being
used to heat a liquid w/c is at 300K. The agitator is 0.61m in
diameter and s a flat-blade turbine rotating at 100 rpm. Hot H2O is
in the heating jacket. The wall surface temp is constant at 355.4K.
Calculate the heat transfer coefficient.
A heat exchanger is to be designed to cool oil from 450 oF to 225oF
by passing it through 1 ID tubes at a velocity of 5 ft/s. Another oil
will flow outside the tubes and will be heated from 100 to 400 oF. If
the overall coefficient of the heat transfer is assumed constant at
50, calculate the length of each tube (i.e, sum of all passes)
required in the following cases:
a. For a double pipe countercurrent H.E
b. For a baffled H.E with 3 shell passes & 6 tube passes
c. For a baffled H.E with 6 shell passes & 12 tube passes
The density and specific heat of both oils may be taken as 55
lbm/ft3 and 0.5 BTU/lb-oF, respectively.
Air for a furnace is preheated from 70degF to 120degF in a
preheater, flue gases are cooled from 450degF to 300degF. Air
enters at 2000 scfm. The U= 35 BTU/hrft2oF. Determine the
corrected LMTD & the required area for a flow pattern.
a. 1-2 shell & tube counterflow
b. Single pass cross flow, both streams are mixed
c. 2-4 shell & tube counterflow
d. Single pass cross flow, air mixed and gas unmixed

Potrebbero piacerti anche