PURE LINK SYSTEMs


Pure drinking water
wherever you want it
PURE Link Systems use a centrally located cooling and
filtration unit, from which the piped chilled and filtered
water is routed through a wet riser with taps located on
floors as required.
This concept has been developed to overcome the issues of
having coolers located throughout a building, which requires
local water and power supplies, meaning increased enabling
works and service visits.

Dispense taps can be positioned in any


of the following service areas:

Reception areas
Meeting rooms
Staff pantry
Office areas
Staff restaurant
Kitchen area (bottling point)

Having used bottled water and


bottle-fed coolers for many years
we felt our move to Alexandra
House presented the perfect
opportunity to upgrade to a PURE
Link System. We are also excited
to have our own branded bottles.
Paul Watling, Facilities Manager
Wilsons Solicitors, Salisbury

www.thepurewaterco.co.uk

TEL: 0844 809 4404

The pure water company LTD

Pure drinking water wherever you want it


At the heart of the PURE Link SYSTEM
is the cooling filtration plant
and the python pipework WHICH IS
THE delivery system for THE remote
dispense of CHILLED drinking water.

1
Bottling Tap
The cobra tap is designed for
bottling or self serve and offers
two dispense points: chilled still
and chilled sparkling.

Restaurant

Kitchen
1

The latest in cooling technology provides water


cooling though ice bank technology, carbonation
and a pump set, all built into one system.
A wall mounted carbon filter (removing taste,
sediment and odours) and UV filter (eliminating
bacteria) are located above the cooler.

Meeting Room

Dispense Tap (self serve)


The elegant and versatile PURE
Touch tap with its digital display
screen serves hot water as well as
ambient, chilled, still or sparkling
water. The instant hot water is ideal
for tea, coffee and all other types
of hot drink.

Office

The cooler lines are subject to routine sanitisation


that ensures maximum hygiene from cooler through
to dispense point.

INDICATIVE SCHEDULE OF WORKS


Phase One 3 days
1. Establish route of python pipework from
the plant areas
2. Establish entry point on each floor level
for dispense points
3. Run and fix python pipework at each floor level.
4. Pressure test pipework
5. Lag and seal pipework
Phase Two 3 days
1. Locate cooler
2. Connect cooler to water and power supplies
3. Fit pump sets
4. Flush system
5. Connect dispense points in appropriate areas
6. Flush system and test
7. Leave system idle for 24 hours to build up ice bank
8. Return to commission and test
9. Staff training, Q&A manual issue

Staff Pantry

Office

3
Python PIPE SECTION
Once the python has been routed
through the riser it is teed off
through the floor or ceiling void
and positioned to allow connection
to the dispense point.

Reception

Central Plant Area


4

Central Cooling AND


Filtration Unit
This can be located in a basement,
plant room, roof void or any area
that provides adequate ventilation
and access to the riser.

TECHNICAL DATA

Cooler Dimensions
Width of cooler unit: 900mm

Depth of cooler unit: 540mm

Height of cooler unit: 690mm

Services
POWER

2 x 13amp electrical sockets

WATER

1 x 15mm mains feed minimum pressure 2bar constant, 24/7

CO2

1 x 'SB' size food safe CO2 cylinder


(spares required to be held on site)

Carbonation functions

Benefits

3 Litre Carbonator Bowl Reserve

Avoids system trip-out and allows larger volume of sparkling


water to be dispensed

Electronically controlled

Less mechanical wear and tear

Priming Assistance
(removes pockets of CO2 from in the system)

Avoids CO2 wastage, system self charges

Built-in Soda Recirculation Pump

Maintains constant temperature

Thermal Cut Out/Switch on Recirculation Pump Motor/


Flood Protection 3 Minute Time Out

Protects internal pumps from burning out

Design Considerations

Benefits

Space for central plant area

Plant Room/LG Area/Roof Void/External (with protection)/


Store Room/Stairwell

Ventilation for central plant

Preferred open area allowing air circulation to prevent cooler


overheating

Quantity of taps per cooler

Up to 12 (subject to location)

Size of access hole for python pipework

80mm diameter (fire proofed post installation)

Route of python pipework from riser to dispense point

Through riser, into floor or ceiling void, into wall or under


counter space

Diameter of hole through counter for dispense point

Cobra Dispense 40mm/Swan Neck 30mm