CONSTRUCTION DOCUMENTATION
THE WOODSTONE
WOODSTONE
THE WOODSTONE
PRESENTATION
VIEWS
Aug 1, 2006
SHEET NUMBER
GENERAL NOTES
125.'
N90E
THESE PLANS SHALL NOT BE USED FOR CONSTRUCTION UNTIL STAMPED AND SIGNED BY AN ENGINEER AND APPROVED BY
THE LOCAL BUILDING DEPARTMENT. THE BUILDER IS EXPECTED TO FOLLOW THESE PLANS, APPLICABLE BUILDING CODES
AND LOCAL ORDINANCES. HE SHALL VERITY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING
WORK. WHILE THESE PLANS ARE DRAWN TO SHOW THE PROPOSED WORK AS ACCURATELY AS POSSIBLE, SCHEMATIC
DETAILS MAY BE USED IN SOME CASES FOR CLARITY. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE
SAME QUALITY AS SIMILAR WORK THAT IS DETAILED.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES.
FOUNDATION AND TRUSS DESIGN SHALL BE VERIFIED BY A QUALIFIED ENGINEER FOR COMPLIANCE WITH SITE REQUIREMENTS.
30'
PROPERTY LINE
DIMENSIONS AND NOTES SHALL TAKE PRECEDENCE OVER THE SCALING OF DRAWINGS.
BUILDING PERFORMANCE
Aug 1, 2006
LUMBER COMING IN CONTACT WITH CONCRETE OR MASONRY SHALL BE TREATED TO A MINIMUM OF 40.CCA. ALL LUMBER IN
CONTINUOUS CONTACT WITH THE GROUND SHALL BE TREATED TO A MINIMUM OF .60 CCA.
WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES.
THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE
DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE
INTENT OF THE PLANS OR NOTES.
HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF REGIONAL AND LOCAL CODES. SEE CALCULATIONS.
PROJECT ADDRESS:
15'
NEW RESIDENCE
FURNACE FIREBOX SHALL HAVE OUTSIDE COMBUSTION AIR SUPPLY PURSUANT TO REGIONAL AND LOCAL CODES.
BUILDING AREA:
ZONING:
APN:
00000-00000-00000
SITE AREA
123-456
PERMIT #:
1234567890
FIRE DISTRICT
KOOTENAI COUNTY
WATER
IDW
FIRST FLOOR:
2780 SQ. FT.
SECOND FLOOR: 634 SQ. FT.
GARAGE:
922 SQ. FT.
PATIO
LOCATED IN A CORRIDOR, HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. ATTICS WITH A MAXIMUM VERTICAL
HEIGHT OF LESS THAN 30" WILL NOT REQUIRE ACCESS OPENINGS.
VENTILATION
SEWAGE DISPOSAL
291.38
'
S9 42
' 31"W
CITY SEWER
PROPOSED STRUCTURE
SOIL PARAMETERS:
BASED ON SOILS INDIGENOUS TO THE AREA:
BEARING PRESSURE - 1000 PSI
LATERAL ACTIVE PRESSURE 35 PSF FLUID EQUIVALENT
SOIL-CONCRETE COEFFICIENT 0.35
SOIL PROFILE SD
ATTIC SHALL HAVE VENTILATION EQUAL TO 1 SQ. FOOT PER 150 SQ. FEET OF ATTIC SPACE. VENTILATION SHALL BE PROTECTED
FROM SNOW AND RAIN AND SHALL BE COVERED WITH GALVANIZED WIRE SCREEN. OPENINGS SHALL BE LOCATED TO PROVIDE
CROSS VENTILATION.
GARAGES SHALL BE VENTED WITH 60 SQUARE INCHES LOCATED 6" ABOVE THE FLOOR SURFACE.
UNDER FLOOR SPACES SHALL HAVE VENTILATION EQUAL TO ONE SQ. FOOT PER 150 SQ. FEET OF FLOOR SPACE. VENTS SHALL BE
CAST INTO THE CONCRETE STEM WALLS AND COVERED WITH GALVANIZED WIRE SCREEN. VENTS SHALL BE LOCATED TO PROVIDE
CROSS VENTILATION.
RAILING NOTES:
w/W
STAIRWAYS SHALL HAVE A MIN. WIDTH OF 34". HAND RAILS MAY ENCROACH A MAX. OF 3 1/2" INTO THE REQUIRED WIDTH.
w/W
w/W
LATERAL DESIGN
TREADS SHALL HAVE A MIN. WIDTH OF 9". STAIR TREADS MUST BE UNIFORM AND CAN NOT VARY FROM THE LARGEST TO THE
SMALLEST BY MORE THAN 3/8".
w/W
w/W
CONCRETE
DRIVEWAY
STAIRWAYS SHALL HAVE MIN. 6'-8" OF HEADROOM AT THE NOSE OF THE STAIR.
w/W
w/W
w/W
ENCLOSED USABLE SPACE UNDER INTERIOR STAIRS SHALL BE PROTECTED ON THE ENCLOSED FACE WITH 5/8" TYPE "X" GYPSUM
WALL BOARD.
w/W
w/W
STAIRWAYS SHALL HAVE AT LEAST ONE HANDRAIL LOCATED 34" TO 38" ABOVE THE NOSING OF TREADS AND LANDINGS. THE
HAND GRIP PORTION OF HANDRAILS SHALL NOT BE LESS THAN 1-1/2" OR GREATER THAN 2" IN CROSS-SECTIONAL DIMENSION.
w/
W
w/
C/
W
w/
W
w/
w/
W
w/
W
SEWER
w/
W
w/
W
w/
W
WALK WAY
w/
C/
W
w/
W
w/
C/
W
w/
C/
w/
W
C/
w/
30'
W
w/
C/
w/
C/
w/
w/
W
ALL EXTERIOR DOORS AND WINDOWS SHALL BE FINISHED WITH WEATHER RESISTANT
COATINGS AND WEATHERSTRIPPED.
34" MIN. HEIGHT GUARDRAILS SHALL BE PROVIDED FOR AT PORCHES, DECKS, BALCONIES, STAIRWAYS AND LANDINGS WHERE
THE ADJACENT SURFACE IS GREATER THAN 24" BELOW.
THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF GUARDRAIL SHALL NOT ALLOW A 6" DIAMETER
SPHERE TO PASS THROUGH.
119
.45
r=9
'
40.
89'
w/
50'
w/
C/
C/
C/
C/
POWER
CABLE
PHONE
HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. THE ENDS OF HANDRAILS SHALL RETURN TO WALL OR
TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL.
w/
C/
C/
EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW WITH FINISH SILL
HEIGHT NOT GREATER THAN 44" ABOVE THE FINISH FLOOR HEIGHT AND SHALL HAVE A
MINIMUM OPENABLE AREA OF 5.7 SQ. FT. EGRESS WINDOWS SHALL NOT HAVE AN
OPENABLE AREA LESS THAN 20" WIDE OR 24" HIGH.
C/
C/
CHIMNEY HEIGHT SHALL BE DETERMINED USING A 10' RADIUS PLANE AND SHALL BE 2' HIGHER
THAN ANY ROOF SURFACE 10' FROM THE CHIMNEY.
WINDOWS SHALL BE DUAL PANE WITH WOOD FRAMES (MIN U VALUE OF 0.6).
MANUFACTURER AND COLOR TO BE DETERMINED BY OWNER.
C/
WATER
C/
/W
C/
ROOFING TO BE LIGHT WEIGHT TILE OVER 30# FELT, 5/8 CDX PLYWOOD/OSB.
FINISH GRADE SHALL SLOPE AWAY FROM STRUCTURE MIN. 1/2" PER FOOT OF RUN FOR 4' MIN.
EXTERIOR FINISH TO BE SIDING OVER 5/8 CDX PLYWOOD/OSB. MATERIAL AND COLOR BY
OWNER.
C/
30'
WATER RESISTANT GYPSUM BACKING BOARD MAY BE INSTALLED OVER OR AS PART OF THE FIRE RESISTANCE RATED SYSTEM IN
SHOWER AND TUB AREAS TO RECEIVE CERAMIC OR PLASTIC WALL TILE OR PLASTIC FINISHED WALL PANELS. THE GYPSUM BOARD
RATING SHALL BE BROUGHT DOWN TO THE FLOOR BEHIND THE FIXTURES.
MINERAL FIBER OR GLASS FIBER INSULATION OF A THICKNESS NOT EXCEEDING THAT OF THE STUD DEPTH MAY BE ADDED WITHIN
THE STUD CAVITY WITHOUT DEGRADING THE FIRE RESISTANCE RATING.
WATER
ALL PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE OF NON-COMBUSTIBLE MATERIAL THAT EXTENDS AT LEAST 6" FROM THE
FACE OF THE ASSEMBLY. THE MEMBRANES ON EACH SIDE OF THE ASSEMBLY AND THE FULL THICKNESS OF THE PENETRATION
SHALL BE SEALED WITH A FIRE RESISTIVE SEALANT SO THAT HOT GASSES CANNOT PASS THROUGH. IN THE EVENT OF A CENTRAL
VACUUM SYSTEM THE PIPE SHALL BE METALLIC FROM THE MACHINE THROUGH THE DRYWALL. SEAL AROUND THE PIPE
PENETRATION.
WOODSTONE
DRIVE
DOORS
PLOT PLAN
SCALE: 1" = 15'
DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60 MINUTES.
DOOR SHALL BE SELF CLOSING.
EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOOR WAY SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE
WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY
GLASS WITH MIN. U-VALUE OF 0.60. PERIMETER OF DOOR SHALL BE WEATHER STIRPPED.
INTERIOR DOORS TO BE SOLID CORE. STYLE AND FINISH BY OWNER.
GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS, MATERIALS AND FINISH TO BE DETERMINED BY OWNER.
KOOTENAI COUNTY
JURISDICTION
WOODSTONE
15'
PLOT PLAN
GENERAL NOTES
OWNER:
WIND:
SEISMIC:
EXPOSURE
SHEET NUMBER
1'10
1'10
5'10
2840 FIXED
90" TOP HT.
23'4 1/2
4'8
4'
5'7
18'7 1/2
5'6
5'6
6'9 1/2
5'7 3/4
3'8
3'8
5'7 3/4
ROOF
OPENINGS
SH P
40 O
16 0" T
9
1'8
14'6
4050 FIXED
2050
CASEMENT
4050 FIXED
5050
FIXED
2050
CASEMENT
HARDWOOD
(15)10" TREADS
(16)7-9/16" RISERS
Tile
2868
50 CFM
WH
18'X8' GARAGE
DOOR W/OPENER
WH
CONCRETE PORCH
GAS
FAU
+90
5050 XO
8'6
2'
3'4
3'4
14'
2'10
GARAGE
9
11'6
6'6
2'2
2'2
13'8 3/4
8:12 SLOPE UP
38'
2019 FIXED
10'
3'
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO THE SAMPLE DRAWINGS THAT
HAVE BEEN PROVIDED TO YOU SOLELY FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF
ARCHITECT, INC MAKES NO WARRANTY THAT THE DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE
AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS
COMPLY WITH ANY BUILDING CODES. THESE SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF
ARCHITECT, INC. AND THE LICENSORS OF THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES
WITH RESPECT TO THESE SAMPLE DRAWINGS, WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR
TRADE USAGE, AND, SPECIFICALLY, MAKE NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE.
10'
2050 FIXED
3'6
This Sample Drawing is owned and/or licensed by Chief Architect, Inc. and is distributed with Chief Architect Software solely
for demonstrative and illustrative purposes as a way to help you more quickly learn and better understand the functional
capabilities of the software program. You agree, under the License Agreement, that you will not reproduce, distribute or use
these Sample Drawings for any other purpose without the prior written consent of Chief Architect, Inc..
9'X8' GARAGE
DOOR W/OPENER
UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR
CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND
CONDITIONS PURSUANT TO THESE SAMPLE DRAWINGS.
2'
2050 FIXED
1/4" = 1'
2'
5050 FIXED
220 Outlet
3'6
2'6
The WoodStone
3'
CONCRETE
LANDING
4'6 1/2
3'
2'6
8'
3'6
3'6
GARAGE
5050 XO EGRESS
5'
2019 FIXED
5'5 1/2
14'
3'6
8'1" CEILING
16'
11168
CROWN MOLDING
2050 FIXED
9080
2'
15'8 1/2
8:12 SLOPE
CEILING UP
8:12 SLOPE
CEILING UP
OCCUPANCY SEPARATION:
BETWEEN R-3 & U-1 SHALL BE A
MIN. 1 HR. CONSTRUCTION. MIN.
5/8" G.W.B. SHALL EXTEND UP TO
ROOF SHEATHING. IF USING THE
LID OPTION THEN 2 LAYERS REQ.
WHEN TRUSSES ARE GREATER
THAN 16" O.C. ALL POST &
BEAMS TO BE WRAPPED. MIN.
20-MINUTE SELF-CLOSING,
TIGHT-FITTING, SOLID WOOD
DOOR MIN. 1 3/8" THICK.
BONUS
9
(3)2X10 PORCH
BEAMS
Cabinet/Work Bench
CABINETS BUILT-IN
BETWEEN TRUSSES
CLOSET
9
6"
3068
DRYWALL, CARPET,
& PAINT ATTIC
STORAGE
8'9 1/2
B
11
15'6
2846
STORAGE
ACCESS
CROWN MOLDING
LIVING
72'
CROWN MOLDING
CARPET
6'
3068
36'5 1/2
8:12 SLOPE
CEILING UP
BATH 4
9
TEMPERED
GLASS
SHOWER
DOOR
3'5
5068
CLOSET
6'11
LIVING
9
OFFICE
9
OFFICE
See thru
Gas FP
9'1" CEILING
HEIGHT
CROWN
MOLDING
2868
15'8 1/2
36'5 1/2
8'1" CEILING
6'9
5'
20-MINUTE MIN.
SELF-CLOSING
11'6
2868
CLOSET
Cabinets
Above,
Shelf,
Base
Cabinet
Storage Cabinet to
Floor to Ceiling
18080
2868
6'
2050 FIXED
3'
10'
3'6
8'
8'
16'
2'
28'
85'6
3'8 1/2
13'1
3'4
HARDWOOD
LAUNDRY
7'8 1/2
18" RAISED
PLATFORM,
Enclosed in
Closet
2'4 1/2
2'6
72'
10'
5068
CLOSET
6'11
BDRM 4
9
2668
Cabinets Above,
Shelf, Base
Cabinet
3068
2'
4'
(3) 2629 SINGLE CASEMENT
EGRESS 75" TOP HEIGHT
4:12 SLOPE
CEILING UP
73'8
4'
8:12 SLOPE
CEILING UP
2868
5068
CLOSET
6'11
8'1" CEILING
LINEN
1640 FIXED
CONCRETE
LANDING
50 CFM
5'
3668
22'
7'3 13/16
DINING
LAUNDRY
D
B
9
DINING
9
ENTRY
9
19'
DN
M BATH
MASTER
BATH
9
CARPET
6'3 5/8
GLASS
DOOR
10'6
Ironing
Board
Cabinet
2868
STORAGE
UNDER
STAIRS
CLOSET
6068
8'
6'8 3/8
BEDROOM
JETTED TUB
3080
HARDWOOD
9'1" CEILING
HEIGHT
Tile
2'X4' VELUX
SKYLIGHT
Above
Counter
Vanity
Cabinet
2'4
B
SLOPE UP
24X32
CRAWL
SPACE
ACCESS
4'
4050 DOUBLE
CASEMENT EGRESS
13'
PLANT SHELF
BATH
21'
8'1" CEILING
2668
7'
Tile
2'4
BATH 3
9
5'
OPEN RAIL
CARPET
SLOPE UP
CROWN MOLDING
8' CEILING HEIGHT
14'8
2668
Tile
2'
2'4 1/2
2'8 1/4
70610
UP
BDRM 3
9
6'
Carpet
20'4
Buffet
2868
LINEN
OPEN BELOW
11'10
5'1 1/2
8'
2'
4'2
2'
ON FIRST FLOOR
3'8
5'4
2868
Tile
4068
3'6
HARDWOOD
70610
1'1 1/2
3'
Tile
7'8 1/4
Carpet
6'2
50 CFM
11'
4'8
5468
2'
3'2
SHELVES
BATH
3'
2'9
GREATFAMILY
ROOM
3'
Walk-in
Shower
56610
4016 XO
TEMP GLASS
FAMILY
REFRIG.
CROWN MOLDING
ENTERTAINMENT
CABINETS
2468
3'6
GAS FP
2868
Tile
BATH 2
9
SLOPE UP
3'6
7'
Carpet
HARDWOOD
PANTRY
50 CFM
8:12 SLOPE UP
2'5 1/2
2868
MASTER BDRM
68
26
2868
M BDRM
9
FLOOR PLANS
FIREPLACE TO CEILING
D.V. THROUGH CHASE
OUT ROOF
20'
ENTERTAINMENT
CABINETS
KITCHEN
5'6
4'6 1/4
KITCHEN
9
2'5 1/2
DBL.
OVEN
4'2 1/2
3'6
Breakfast Bar
ISLAND
5'
BEDROOM
B
SLOPE UP
1/4" = 1'
3068
6'
4'6
6'
CLOSET
6068
4050 DOUBLE
CASEMENT EGRESS
9'
BDRM 2
9
2'
5'
8:12 SLOPE UP
2'6
TEMP GLASS
EGRESS
DOOR
8:12 SLOPE UP
14'
2'X4' VELUX
SKYLIGHTS
3068
TEMP GLASS
DOOR
D/W
4'9 1/2
NOOK
3'6
3650 DOUBLE
CASEMENT
2'2
1'8
WOODSTONE
3'8
Aug 1, 2006
1'8
16
90 40
"T S
O H
P
9'
3'
2'4
B
11
11'2
SHEET NUMBER
PATIO
2'
16'6
1'8
3'8
1'8
14'6
23'4 1/2
18'7 1/2
3'6
2. PROVIDE CONTINUOUS BLOCKING OR RIM JOIST AT PERIMETER.
3. ALL CANTILEVERED JOISTS ARE TO HAVE LATERAL SUPPORT BLOCKING AT BEARING LOCATIONS - SEE PLANS.
1'8
1'8
SHEET NUMBER
85'6
2. ALL BACKFILL AND SOIL BELOW SLABS AND FOOTINGS MUST BE COMPACTED TO 2000 PSF MIN.
3. FOUNDATION CONTRACTOR IS TO PROVIDE 1/2" X 10" ANCHOR BOLTS AT 72" O.C. AND 12" FROM CORNERS AT ALL PERIMETER
FOUNDATION WALLS AND ALL BEARING WALLS.
14'
AA
4. CONTRACTOR IS RESPONSIBLE FOR ALL REINFORCEMENT IN CONCRETE WALLS AND BELOW SLABS WHERE REQUIRED. ALL
REINFORCEMENT IS TO MEET LOCAL CODES AND IS TO BE INSPECTED BY BUILDING DEPT. OFFICIALS.
20'
AA
Aug 1, 2006
CONCRETE NOTES:
FOUNDATION STEEL:
FOUNDATION PLAN
BB
7'
7'
2'8" MIN. WIDTH ALTERNATE BRACE PANEL PER 1997 UBC 2320.11.4
NAILING: ALL PANEL EDGES - 8d AT 6" O/C. IN FIELD 8d AT 12" O/C.
PROVIDE TIE DOWNS AT ENDS OF PANEL WITH UPLIFT CAPACITY OF NOT LESS THAN 1800 LBS. SET INTO FOUNDATION.
13'
SIMPSON IT HANGER
BB
2X8 PT SILL
1/2"X10" AB
FINISHED GRADE
AA
11'
11'6
3/8" = 1'
3'
AA
AA
R-30 INSULATION
I-JOISTS
1'11 9/16
2'4
DD
18" MIN.
2'4
6'6
2'4
2 - #4 STEEL REBAR
8"
20'
18'2
22'
9'2
1'4
CONCRETE FTG
CC
GARAGE SLAB 1/4" PER FOOT
SLOPE TO DRAIN OUT DOORS
BB
GARAGE
38'
WOODSTONE
73'8
4'
6'
2'
2'
11"
10"
AA
8"X16" FOOTING
8"X36" CONC.
STEM WALL
3'2
73'8
SIDING
PER SPECS
TOP OF FOUNDATION
GARAGE FLOOR 4"
CONCRETE SLAB W/#3
REBAR 24" O.C. EACH WAY,
OVER PEA GRAVEL FILL
R-19 WALL
INSULATION
TYVEK
HOUSEWRAP
2'4
1'10
10'
9'2
8"
1'4
2'
3'11
2'
CC
10'
16'
2'
9'6
6'6
85'6
14'
10'
8'
3'6
2'4
4'
8"
8"
2'
1'4
DD
2'
906 sq ft
SHEET NUMBER
STHD
STHD
STHD
5. PROVIDE JOIST HANGERS AT ALL LOCATIONS AT WHICH JOISTS BUTT UP TO BEAMS OF OTHER BUILT-UP JOISTS - SEE PLANS.
STHD
6. PROVIDE PRESSURE TREATED OR GALVANIZED FLASHING SEPARATION BETWEEN JOIST AND CONCRETE AT ALL LOCATIONS.
AA
PAI35
8' O.C.
IUT11
@ EACH
2. ALL BACKFILL AND SOIL BELOW SLABS AND FOOTINGS MUST BE COMPACTED TO 2000 PSF MIN.
3. FOUNDATION CONTRACTOR IS TO PROVIDE 1/2" X 10" ANCHOR BOLTS AT 72" O.C. AND 12" FROM CORNERS AT ALL PERIMETER
FOUNDATION WALLS AND ALL BEARING WALLS.
AA
4. CONTRACTOR IS RESPONSIBLE FOR ALL REINFORCEMENT IN CONCRETE WALLS AND BELOW SLABS WHERE REQUIRED. ALL
REINFORCEMENT IS TO MEET LOCAL CODES AND IS TO BE INSPECTED BY BUILDING DEPT. OFFICIALS.
5. VENTILATION 1 S.F. PER 150 S.F. OF CRAWL SPACE.
CONCRETE NOTES:
Aug 1, 2006
FOUNDATION STEEL:
WALLS UNDER 4'0":
#4 REBAR VERT. AT 48" O/C.
#4 REBAR HORIZ. AT 24" O/C.
FLOOR FRAMING
STHD
WALLS OVER 4'0":
#4 REBAR VERT. AND HORIZ. AT 18" O/C.
FOOTINGS:
(2)#4 REBAR CONTINUOUS IN FOOTING.
BB
SHEAR WALL-A [SW-A]:
4' MIN. WIDTH BRACE PANEL PER 1997 UBC 2320.11.3
NAILING: ALL PANEL EDGES - 8d AT 6" O/C. IN FIELD 8d AT 12" O/C.
SHEATHING TO COVER FULL DEPTH OF RIM JOISTS OR SOLID BLOCKED JOIST ENDS.
STHD
STHD
CRAWL
SPACE
ACCESS
STHD
BB
AA
ONE #4
REBAR IN
SHEAR CONE
STHD
10"
STHD
AA
STHD
AA
2X8 PT MUD SILL
DD
SIMPSON IT JOIST HANGERS
18'2
2'4
6'6
CC
Simpson Strong-Tie
STHD Corner Installation
Simpson Strong-Tie
PAI35
(Hanger not Shown)
2'4
FASTEN WITH
10dx1 1/2" NAILS
INTO WEB STIFFENERS
Simpson Strong-Tie
IUT11 (with web stiffener)
STHD
9'2
1 "2
STHD
PAI35
IUT11
WOODSTONE
STHD
2'
3'2
MIN. REBAR
LENGTH 30"
STHD
STHD
STHD
STHD
STHD
9'2
1'10
3'11
STHD
11"
12" MIN.
REBAR LENGTH
SHEET NUMBER
TR-59
CANTILEVER ROOF TRUSSES OVER PATIO
TR-20
TR-17
TR-26
ROOF PLAN
TR-16
TR-15
TR-14
TR-26
TR-13
TR-12
TR-11
TR-10
TR-9
TR-8
GREAT ROOM
TR-7
TR-6
TR-5
TR-4
TR-2
TR-3
TR-1
TR-0
TR-42
TR-81
TR-42
TR-42
TR-94
TR-26
TR-55
TR-56
TR-57
TR-58
Aug 1, 2006
TR-51
TR-45
TR-64
TR-54
TR-21
TR-38
TR-36
TR-22
TR-52
TR-33
TR-37
TR-53
TR-23
TR-50
TR
3
-4
TR-24
TR-49
TR-25
TR-48
TR-44
TR-27
4
-3
TR-39
TR
TR-31
TR-47
TR-30
TR-35
TR-79
TR-29
TR-28
TR-32
TR-88
TR-41
TR-41
TR-89
TR-89
B
11
TR-89
8 / 12
TRUSS NOTES:
TR-88
8 / 12
8 / 12
TR-89
DN
DN
8 / 12
DN
TR-88
TR-88
8 / 12
WOODSTONE
TR-40
TR-89
DN
8 / 12
TR-88
8 / 12
DN
8 / 12
8 / 12
4 / 12
12. PROVIDE 1" MIN. AIR GAP AT EAVES WITH INSULATION BAFFLES TYP. AT ALL TRUSS BAYS.
DN
DN
8 / 12
8 / 12
TR-62
DN
DN
8 / 12
8 / 12
DN
8 / 12
DN
8 / 12
DN
DN
Simpson Strong-Tie
H15
Simpson Strong-Tie
A35F
DN
Simpson Strong-Tie
H8 Hip Valley Truss
DN
8 / 12
14. PROVIDE GALV. ROOF VENTS ON BACKSIDE OF ROOFLINE ABOVE CONDITIONED AREA.
Simpson Strong-Tie
A35- Chimney Framing
DN
8 / 12
11. ATTIC VENTILATION: 2780 S.F. / 300 = 9.3 S.F. REQUIRED ABOVE HOUSE.
2"
MIN.
END DIST.
DN
DN
TR-87
TR-61
DN
8 / 12
TR-86
DN
8 / 12
TR-90
TR-93
TR-91
DN
DN
Simpson Strong-Tie
THA29
DN
DN
8 / 12
DN
DN
DN
8 / 12
8 / 12
8 / 12
B
11
DN
DN
8 / 12
DN
TR-84
TR-85
8 / 12
DN
DN
DN
8 / 12
TR-83
DN
8 / 12
5. NON BEARING WALLS SHOULD BE HELD DOWN FROM THE TRUSS BOTTOM CHORD W/
SIMPSON STC TO INSURE THAT THE TRUSS BOTTOM CHORD WILL NOT BEAR ON THE WALL.
8 / 12
TR-82
8 / 12
4. ALL TRUSSES SHALL HAVE DESIGN DETAILS & DRAWINGS ON SITE FOR FRAMING INSPECTION.
TR-92
TR-78
TR-46
TR
3
-6
TR-45
TR-65
TR-77
TR-46
TR-19
TR-66
TR-76
-1
8
TR-19
TR
TR-67
TR-69
TR- **
TR-70
TR-71
TR-27
TR-74
TR-72
TR-73
TR-68
TR-60
12
12
13'9
Aug 1, 2006
SHEET NUMBER
TOP OF RIDGE
22'-10"
FINISHED FLOOR
T.O.W. CONCRETE
GRADE
FRONT ELEVATION
1/4" = 1'
1/8" = 1'
REAR PORCH
LEFT ELEVATION
REAR PORCH
RIGHT ELEVATION
REAR ELEVATION
1/4" = 1'
CSV EUROPEAN
CASTLE STONE
WOODSTONE
EXTERIOR
ELEVATIONS
9'1
TOP OF PLATE
9'-0"
1/8" = 1'
1/8" = 1'
RIGHT ELEVATION
1/4" = 1'
6500 N. Mineral Dr. Coeur d'Alene, ID. 83815
800-482-4433
www.chiefarchitect.com
WOODSTONE
EXTERIOR
ELEVATIONS
1/4" = 1'
LEFT ELEVATION
DRAWN BY: A.F.
Aug 1, 2006
SHEET NUMBER
WP
R
4 4 3
SMOKE DETECTORS SHALL BE POWERED FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL
SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP.
SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING AREA, AT POINTS CENTRALLY LOCATED IN THE CORRIDOR OR
AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA.
SMOKE DETECTORS SHALL BE INSTALLED IN THE HALLWAY AND IN THE ADJACENT ROOM WHEN THE CEILING HEIGHT OF A
ROOM OPEN TO THE HALLWAY SERVING THE BETROOM EXCEEDS THAT OF THE HALLWAY BY 24" OR MORE.
D/W
3
3
WP
3
3
3
WP
SMOKE DETECTORS:
R
4 4
SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING IN WHICH THEY ARE
LOCATED.
LIGHTING:
THE PRIMARY LIGHTING FOR KITCHENS AND BATHROOMS SHALL HAVE A MIN EFFICIENCY OF 40 LUMENS PER WATT.
Aug 1, 2006
COVERED JUNCTION BOXES SHALL BE PROVIDED UNDER KITCHEN SINKS TO PROVIDE POWER FOR DISHWASHERS, GARBAGE
DISPOSERS AND OTHER APPLIANCES AS REQUIRED.
SHEET NUMBER
ELECTRICAL NOTES
INCANDESCENT LIGHTS SHALL NOT BE PLACED CLOSER THAN 12" FROM THE NEAREST POINT OF A STORAGE AREA ON A
SHELF.
SD
SD
ELECTRICAL PLAN
R
3
VAC SWITCH
3
SD
LIGHTING WILL BE PROVIDED FOR MECHANICAL EQUIPMENT LOCATED IN AN ATTIC OR UNDER FLOOR SPACE. A LIGHT
SWITCH SHALL BE PROVIDED AT THE ACCESS OPENING.
GFCI
4
SD
WP FIXTURE
3
4
4 4
3
3
SD
GFCI
DM
UP
R
3
GFCI
DIMMER SWITCHES
GFCI
R
GFCI
SD
ROPE LIGHT AT
STRINGER CONTINUOUS
TOP TO BOTTOM.
SD
R
R
FLUORESCENT
PHOTO CELL
DN
4
4
R
4 4
WP
FLUORESCENT
WH
WP
SD
B
11
R
R
Outlets,
Recessed
lighting in
eves
Fluorescent lighting
R
GFCI
WP
The WoodStone
DRYWALL, CARPET,
& PAINT ATTIC
STORAGE
CABINETS BUILT-IN
BETWEEN TRUSSES
This Sample Drawing is owned and/or licensed by Chief Architect, Inc. and is distributed with Chief Architect Software solely
for demonstrative and illustrative purposes as a way to help you more quickly learn and better understand the functional
capabilities of the software program. You agree, under the License Agreement, that you will not reproduce, distribute or use
these Sample Drawings for any other purpose without the prior written consent of Chief Architect, Inc..
UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR
CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND
CONDITIONS PURSUANT TO THESE SAMPLE DRAWINGS.
220V OUTLET
SINGLE POLE SWITCH
3 WAY SWITCH
WP
Storage
Access area.
Carpet, Paint
GFI
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO THE SAMPLE DRAWINGS THAT
HAVE BEEN PROVIDED TO YOU SOLELY FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF
ARCHITECT, INC MAKES NO WARRANTY THAT THE DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE
AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS
COMPLY WITH ANY BUILDING CODES. THESE SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF
ARCHITECT, INC. AND THE LICENSORS OF THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES
WITH RESPECT TO THESE SAMPLE DRAWINGS, WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR
TRADE USAGE, AND, SPECIFICALLY, MAKE NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE.
ELECTRICAL SCHEDULE
CEILING FAN
4
4
TELEPHONE
TV
T
WP
TELEVISION
THERMOSTAT
INTERCOM
C5/TV
ELECTRICAL OUTLETS
DATA TERMINAL/TV
ELECTRIC OUTLETS IN BATHROOMS WITHIN SIX FEET OF SINKS, IN GARAGES, BASEMENTS AND OUTDOORS SHALL BE GFI PROTECTED.
EXTERIOR ELECTRICAL OUTLETS SHALL BE PROVIDED AT THE FRONT AND BACK OF THE BUILDING.
SD
SMOKE DETECTOR
ELECTRICAL OUTLETS SHALL BE PLACED NOT FURTHER THAT 12' O.C. ON EVERY WALL AND SHALL BE PLACED ON WALLS GREATER THAN 2' IN LENGTH.
COUNTERTOPS 12" AND WIDER SHALL HAVE ELECTRICAL OUTLETS SPACED NOT GREATER THAN 48" O.C.
HALLWAYS 10' OR GREATER IN LENGTH SHALL HAVE AT LEAST ONE ELECTRICAL OUTLET.
MECHANICAL EQUIPMENT SHALL HAVE AN ELECTRICAL OUTLET LOCATED WITHIN 25'.
AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND COUNTER SPACES WITH A LONG DIMENSION OF 24" OR GREATER AND A SHORT DIMENSION OF 12" OR GREATER.
PROVIDE TWO OR MORE DEDICATED 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM OR SIMILAR AREA.
AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH PENINSULA COUNTER WITH A LONG DIMENSION OF 24" OR GREATER AND A SHORT TIMENSION OF 12" OR GREATER.
ELECTRICAL PLAN
CEILING FAN
SCALE: 1/4"=1'0"
FLUORESCENT CEILING FIXTURE
SD
TEMPERED
GLASS
SHOWER
DOOR
WOODSTONE
WH
CLOSET
SD
SHEET NUMBER
B
11
11'2
2'4
9'
3'
1'8
3'8
2'2
1'10
1'8
14'6
1'10
5'10
23'4 1/2
4'8
4'
5'7
18'7 1/2
5'6
5'6
6'9 1/2
5'7 3/4
3'8
3'8
5'7 3/4
OPEN BELOW
C
3'6
3'8
C/W
C/W
C/W
C/W
C/W
C/W
C/W
C/W
4'2
H/W
H/W
H/W
8'
H/W
H/W
H/W
11'10
H/W
H/W
H/W
H/W
20'4
H/W
H/W
6'
w/W
w/W
w/W
w/W
w/W
w/W
w/W
w/W
w/W
C/O
C
w/W
H
C/W
C/W
H/W
w/W
/W
H/W
C/W
/W
w/W
MASTER BATH
C/W
H/W
H/W
C/W
H/W
C
H
/W
14'8
w/W
H/W
/W
C
w/W
H/W
C/W
H/W
13'1
LAUNDRY
7'8 1/2
G
G
OFFICE
LIVING
8'9 1/2
C/O H
WH
6"
2'
2'6
2'
C
w/W
C/W
WH
C
4'
w/W
C/W
11'6
C/O
2-WAY
2'
3'4
3'4
14'
2'10
5'5 1/2
4'6 1/2
3'
2'6
C/W
B
11
w/W
C/W
22'
19'
2'6
11'6
6'6
w/W
14'
10'
8'
3'6
WOODSTONE
11'
6'8 3/8
CLOSET
8'
DINING
w/W
H/W
C/W
C/W
2'5 1/2
/W
13'
BEDROOM
G
C/W
73'8
w/W
2'
5'
w/W
C/W
CABINETS BUILT-IN
BETWEEN TRUSSES
w/W
C / WC
C/W
2'4
BATH
w/W
w/W
2'
DRYWALL, CARPET,
& PAINT ATTIC
STORAGE
H / WH
w/W
w/W
C/W
w/W
C
w/W
H
w/W
7'8 1/4
2'4
H/W
H/W
C/W
w/W
3'
38'
H/W
/W
w/W
H
C
w/W
w/W
w/W
2'2
3'
C/W
2'8 1/4
H/W
C/W
6'2
H/W
UP
C/W
3'6
H/W
C/W
C/W
7'
C/W
H/W
C/W
C/W
3'6
H
H/ W
2'2
20'
G
G
5'1 1/2
3'6
PLUMBING/
HVAC PLAN
2'5 1/2
2'9
3'6
7'
w/W
/W
1'1 1/2
C/W
3'5
C/W
H/W
4'8
C/W
5'4
CLOSET
H/W
3'2
C/W
BATH
C/W
w/W
C/W
H/W
w/W
C/W
C/W
C/W
/W
3'
C/W
H/W
/W
C/W
C/W
/W
/W
TEMPERED
C/W
GLASS w / W
H/W
H SHOWER
DOOR
FAMILY
H/W
C/W
w/W
CLOSET
PANTRY
6'
C/W
w/W
H/W
C/W
w/W
3'8 1/2
C/W
/W
w
C/O
3'4
13'8 3/4
4'2 1/2
2'6
CLOSET
4'6 1/4
5'
3'6
5'
KITCHEN
5'6
G
C/W
C/W
G
w/W
MASTER BDRM
CLOSET
14'
C/W
H/W
C/W
w/W
2'4 1/2
C/W
w/W
C/W
H/W
C/W
w/W
BEDROOM
Aug 1, 2006
4'9 1/2
C/W
2'
C/W
6'
D/W
4'6
CLOSET
9'
C/W
C/W
w/W
C/W
DN
6'
ALL WASTE LINE TO BE CAST IRON, SIZED FOR APPLICATION. PROVIDE CLEANOUTS
PER UPC 2002 OR AS SHOWN ON PLAN.
C
15'6
w/W
C/W
3'6
3'6
8'
w/W
w/W
2'
C/W
16'
28'
2'
8'
C/W
3'
10'
C/W
w/W
FUEL BURNING WATER HEATERS SHALL BE INSTALLED PER 2002 UPC SECTION
501.0 AND TABLE 5-1 FOR COMBUSTION AIR.
This Sample Drawing is owned and/or licensed by Chief Architect, Inc. and is distributed with Chief Architect Software solely
for demonstrative and illustrative purposes as a way to help you more quickly learn and better understand the functional
capabilities of the software program. You agree, under the License Agreement, that you will not reproduce, distribute or use
these Sample Drawings for any other purpose without the prior written consent of Chief Architect, Inc..
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO THE SAMPLE DRAWINGS THAT
HAVE BEEN PROVIDED TO YOU SOLELY FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF
ARCHITECT, INC MAKES NO WARRANTY THAT THE DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE
AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS
COMPLY WITH ANY BUILDING CODES. THESE SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF
ARCHITECT, INC. AND THE LICENSORS OF THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES
WITH RESPECT TO THESE SAMPLE DRAWINGS, WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR
TRADE USAGE, AND, SPECIFICALLY, MAKE NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE.
UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR
CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND
CONDITIONS PURSUANT TO THESE SAMPLE DRAWINGS.
2'
w/W
8'6
3'6
10'
3'6
w/W
C/W
w/W
C/W
C/W
ALL GAS LINES SHALL BE SIZED FOR APPLIANCE LOAD. "BLACK" PIPE SHALL BE
USED INSIDE THE BUILDING, "GREEN" PIPE WHERE UNDERGROUND OR EXPOSED
TO WEATHER. ALL JOINTS SHALL BE TAPED WHERE BURIED OR EXPOSED TO
WEATHER.
The WoodStone
NOTICE AND DISCLAIMER
3'
w/W
GARAGE
C/W
G
C/W
METALLIC GAS PIPE, WATER PIPE, AND FOUNDATION REINFORCING BARS SHALL BE
BONDED TO THE ELECTRICAL SERVICE GROUND.
5'
ATTIC
9'2 7/16
BEDROOM
DORMER
6' 5/16
BONUS
(FAMILY ROOM)
8'1 1/8
ENGINEERED ATTIC
ROOF TRUSSES
Aug 1, 2006
SHEET NUMBER
16'
5'
ATTIC
3'10 3/16
ATTIC
R-38 INSULATION
SIMPSON H-1 TRUSS TO
TOP PLATE CONNECTORS
OFFICE
10'3 1/4
MASTER BEDROOM
R-21 INSUL.
R-21 INSUL.
1/2" GWB
TYVEK HOUSEWRAP
FLOOR SHEATHING
GLUED & SCREWED
I-JOISTS
2X6 PLATE
R-30 INSUL.
BLOCKING ABOVE
CRIPPLE WALL
I-JOISTS
I-JOISTS
R-30 INSUL.
2X6 PLATE
8"
8"
14"
R-19 WALL
INSULATION
TYVEK
HOUSEWRAP
FINISHED GRADE
6"
REBAR PER
STRUCTURAL
ENGINEER
8"
14"
16"
(2)#4 REBAR
CONT. IN FTGS.
40 1/4 X 49 X 24
APPLIANCE SPECIFICATIONS
1'4
FRAMING SPECIFICATIONS
MODEL: CST 38
SECTION 2
4'1
2'8
5 3/4"
1'9
5 1/4"
4' 3/4
10 1/2"
1' 1/2
3'2
3'3 1/4
END VIEW
1' 1/2
3'6 3/4
4' 3/4
3'6 1/2
SKYLIGHT SHAFT
GAS LINE
COMBUSTION AIRACCESS
3 1/16"
2 13/16"
3 7/8"
WOODSTONE
8"
16"
KEYWAY
8"
8"
24"
6 MIL VAPOR BARRIER
EXTEND MIN. 1' UP WALL
2'4
REBAR PER
STRUCTURAL
ENGINEER
8"
24"
KEYWAY
8"
8"
6"
1/2"X10" AB'S
PER PLAN
SIDING
PER SPECS
1/2"X10" AB'S
1/2"X10" AB'S
1/2"X10" AB'S
PER PLAN
GARAGE
TOP OF FOUNDATION
TYVEK HOUSEWRAP
RIM JOIST
FINISHED GRADE
FLOOR SHEATHING
GLUED & SCREWED
FLOOR SHEATHING
GLUED & SCREWED
I-JOISTS
R-30 INSUL.
FLOOR SHEATHING
GLUED & SCREWED
R-30 INSUL.
1/2" GWB
BLOCKING ABOVE
CRIPPLE WALL
SECTIONS
DETAILS
FRONT VIEW
END VIEW
3'6 3/4
1'11 15/16
3'4 1
SUPERIOR.
/4
1'1
BEDROOM
6
5/1
11
STAIR WELL
FRAMING
BATH
BONUS ROOM
sf18.dwg
KITCHEN
JOIST/HEADER
GARAGE
HALL
ATTACH TO HEADER WITH TH
STEEL HEADER ATTACHMENT B
LAMINATED SUPPORT BEAM
NOTE:
SECTION 3
SECTION SCALE: 3/8"=1'0"
2 9/1
6"
3'3 1/4
TOP VIEW
7'2 1/2
8"
2'1 3/16
4X4
HEADER
2X4
FALSE HEADER
(OPTIONAL)
2'6 15/16
2'6
2'6
1'2
10"
7'6
2'3
5'6 1/2
2'
2'
KITCHEN - A
KITCHEN - D
KITCHEN PERSPECTIVES
3'6
2'
2'3
1'6
BATH - 4 VANITY
BATH - 2 VANITY
APPLIANCE SCHEDULE
NUMBER
A01
A02
A03
A04
A05
A06
A07
QTY
1
1
1
1
1
2
1
FLOOR
1
1
1
1
1
1
1
DIMENSIONS
WIDTH
26 3/4X22X60 1/2 " 26 3/4 "
36X30 3/4X66 "
36 "
28X27X42 "
28 "
24X40X45 "
24 "
18 1/2X28 5/8X60 " 18 1/2 "
12X108X8 "
12 "
30X20X1 7/8 "
30 "
DEPTH
22 "
30 3/4 "
27 "
40 "
28 5/8 "
108 "
20 "
HEIGHT
60 1/2 "
66 "
42 "
45 "
60 "
8"
1 7/8 "
DESCRIPTION
STACKED 27"
SIDE-BY-SIDE
DRYER (ELECTRIC)
DOUBLE SIDED
18" W/ GAS@UPFLOW
GARAGE@DOOR OPENER
GAS 30"
CODE
MANUFACTURER
COMMENTS
QTY
1
1
1
1
1
2
1
2'3
2'6
3'8
3'3
3'8
3'7
3'5
3'7
NUMBER
A01
A02
A03
A04
A05
A06
A07
OFFICE CABINETRY
Aug 1, 2006
INTERIOR ELEVATIONS
PERSPECTIVES
2'
3'
STAIRCASE VIEW
KITCHEN - C
1'6
2'6
WOODSTONE
2'6
2'7
SHEET NUMBER
2'6
3'8
WOODSTONE
INTERIOR ELEVATIONS
PERSPECTIVES
Aug 1, 2006
SHEET NUMBER