Sei sulla pagina 1di 8

Datasheet

Safety Equipment Datasheet


ConocoPhillips (Grissik) Ltd.

B-84567-SB-HP1-DSR-ST-72-0002 Rev. 1
Page 2 of 2

Revision Sheet
ConocoPhillips (Grissik) Ltd.

REVISION

DATE

DESCRIPTION OF CHANGE

0A

07-May-2015

First Issuance

0B

19-Jun-2015

Issued for Approval:


Revise Document Title
Revise Document Header
Update Number of SCBA
Update First Aid Box
Update Stretcher

14-Jul-2015

Issued for Use:


Revise Document Title

Additional Approvers (If Applicable)


Name

Designation

Signature

Date

SUBAN COMPRESSION PROJECT


Safety Equipment Datasheet
CLIENT
LOCATION

ConocoPhillips (Grissik) Ltd.

DOC NO.

South Sumatra, Indonesia

REVISION NO. 1
PAGE

B-84567-SB-HP1-DSR-ST-72-0002
3

DATE July 14, 2015


OF

Safety Equipment List / Datasheet Index


1
2
3
4
5
6
7
8
9
10
11
12
13

No.

ITEM DESCRIPTION

Minimum Quantity
(EA)

1.

FIRST AID KIT

2.

SELF CONTAINED BREATHING


APPARATUS

Reference Layout Document

note 1
note 1, 2
B-84567-SB-PP1-LAY-ST-00-0002

3.

FIRE BLANKET

note 1

4.

STRETCHER

note 1

14
15

note 1: Location inside Power Control Room # 3

16

note 2: Each SCBA's quantity shall be provided with spare bottle

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Remark

SUBAN COMPRESSION PROJECT


Safety Equipment Datasheet
CLIENT

ConocoPhillips (Grissik) Ltd.

DOC NO.

B-84567-SB-HP1-DSR-ST-72-0002

LOCATION

South Sumatra, Indonesia

REVISION NO.

PAGE

DATE July 14, 2015


OF

FIRST AID BOX DATA SHEET


1 ITEM NO.

2 SERVICE

First Aid Box

MIN. REQUIRED :

SET

DESIGN CRITERIA

3
4
5

1. Type

Self-standing type with stretcher, Indoor installation

2. Location

Indoor (Power Control Room #3 )

One kit appropriate for up to 25 people, containing bandages, dressings,

6
7
8
9
10

3. Containing items
-

First Aid Kit

11

adhesive tape, scissors, cotton wool, antiseptic, mouth to mouth resuscitators,

12

safe pins, inflatable splints, set of tweezers.

13
14

Wool blanket

One set, by Maker's standard

Stretcher

One set, foldable type, equipped with patient restraints, foot rest,

15
16

non-absorbent foam pad and hand hold for easy transport.

17
18
19

4. Painting

Green

5. Approval

UL listed or FM approved

6. Accessories

Expansion bolts & Nuts

7. Test & Inspection

Dimension & Visual inspection

8. Letter

White letter "FIRST AID BOX"

20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

SUBAN COMPRESSION PROJECT


Safety Equipment Datasheet
CLIENT

ConocoPhillips (Grissik) Ltd.

DOC NO.

B-84567-SB-HP1-DSR-ST-72-0002

LOCATION

South Sumatra, Indonesia

REVISION NO.

PAGE

DATE July 14, 2015


OF

SELF CONTAINED BREATHING APPARATUS (SCBA) DATA SHEET


1 ITEM NO.

2 SERVICE

Breathing Apparatus

NO. REQUIRED :

SET

DESIGN CRITERIA

3
4
5

1. General Type

- Positive pressure type; single cylinder

- Able to provide respiratory protection in toxic and hazardous atmospheres

- Fitted with a pressure gauge to indicate the cylinder contents remaining and also show

by means of a red sector on the dial when approximately a 10 minute supply of air remains in the cylinder

10
11

- Fitted with a warning whistle


- Resistant to corrosion

12

- Be suitable for use with radio equipment

13

- The quick connect hose fittings supplied on the air masks shall fit all breathing air supply connections, bottles and

14
15
16
17

manifolds.
- A mounted block assembly with quick connect to accept the SCBA quick connects such as those supplied
on breathing air hose assemblies
- Each SCBA' s unit shall be provided with spare bottles and located near SCBA storage.

18
19

2. Location

Indoor (Power Control Room #3 )

20
21
22

3. Material and Containing items ( see note 1,3 ) :


-

Cylinder
Type

Rechargeable breathing air cylinder

24

Material

Carbon Fiber Reinforced Plastic (FRP)

25

Maximum Chargeable
Pressure

300 barg/4352 psi

Type

Have a robust positive action handwheel and prevent accidentally disconnected

Material

Shall use minimum Stainless Steel

enabling wearer to confirm own whistle operation in particularly

23

26
27
28

29

Cylinder Valve
in use once the cylinder valve turned on

30
31
32
33

Warning Whistle unit


Type

34
35

noisy environments

36

Set to operate when a 10 minute supply of air remains in the cylinder.

37
38

39

Backplate
Type

Shall fitted with Stainles Steel cylinder band or kevlar composite material

Material

Manufactured from Stainless Steel or Fiber Carbon struts

Type

Back mount type harness with adjustable shoulder straps and waist belt

Material

Polyester or woven terylene or equivalent

with safety lock and adjustable for different cylinder size.

40
41
42
43
44

Harness
Provided with stainless steel fittings and adjusters

45
46
47
48

SUBAN COMPRESSION PROJECT


Safety Equipment Datasheet
CLIENT

ConocoPhillips (Grissik) Ltd.

DOC NO.

B-84567-SB-HP1-DSR-ST-72-0002

LOCATION

South Sumatra, Indonesia

REVISION NO.

PAGE

DATE July 14, 2015


OF

SELF CONTAINED BREATHING APPARATUS (SCBA) DATA SHEET


1 ITEM NO.

2 SERVICE

Breathing Apparatus

NO. REQUIRED :

SET

DESIGN CRITERIA

3
4

Face Mask

Type

Constructed with a lightweight non-dermatitic neoprene full face mask

Material

Shall comply with test standard NIOSH 42 CFR part 84

4. Working duration

30 minutes at breathing rate of minimum 40 L/min

5. Cabinet or Wall Mounted

Hanger cabinet or weatherproof box ( see note 2 ) contain expansion bolt - nut

UL listed or FM approved

8
9
10
11

Hanger

12
13
14

6. Approval

Test Standard NIOSH 42 CRF part 84

15
16
17
18
19

7. Test & Inspection


-

*Chemical Agent Permeation and Penetration Resistance Against Distilled Sulfur Mustard and SARIN

20

*Laboratory Respirator Protection Level (LRPL)

21
22

As per NIOSH

Visual inspection, test certification, and certification of compliance

23
24

8. Letter

Write "SCBA CABINET" (50 mm high letters)

25
26
27
28

Notes
1. The use of copper material is not acceptable such as copper or copper alloys including brass and bronze for any piping,
piping components and equipment.

29

2. The SCBA storage shall be wall mounted cabinet for indoor installation or weatherproof cabinet for outdoor installation.

30

3. Not limited with containing items.

31
32
33
34
35
36
37
38
39
40
41
42
43
44
45

SUBAN COMPRESSION PROJECT


Safety Equipment Datasheet
CLIENT

ConocoPhillips (Grissik) Ltd.

DOC NO.

B-84567-SB-HP1-DSR-ST-72-0002

LOCATION

South Sumatra, Indonesia

REVISION NO.

PAGE

DATE July 14, 2015


OF

FIRE BLANKET DATA SHEET


1 ITEM NO.

2 SERVICE

Fire Blanket

NO. REQUIRED :

SET

DESIGN CRITERIA

3
4
5

1. Type

Non combustible fire blanket

2. Location

Indoor (Power Control Room #3 )

3. Blanket Dimension

Min. 6 ft X 6 ft size

6
7
8
9
10
11

4. Material (See Note 1)

12

Blanket

100% Wool Fire Blanket, non asbestos material

13

Container

'- Material : PVC

14

'- Wall-mountable

15

- Dimensions as per manufacturing standard

16
17

5. Painting

Manufacturing Standard

6. Approval

- UL listed or FM approved

18
19

- Comply with NFPA 701

20
22
21

7. Accessories

Expansion bolts & Nuts

8. Test & Inspection

Dimension & Visual inspection

9. Letter

Write "FIRE BLANKETS" (50 mm high letters)

22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

Notes
1. The use of copper material is not acceptable such as copper or copper alloys including brass and
bronze for any piping, piping components and equipment.

SUBAN COMPRESSION PROJECT


Safety Equipment Datasheet
CLIENT

ConocoPhillips (Grissik) Ltd.

DOC NO.

B-84567-SB-HP1-DSR-ST-72-0002

LOCATION

South Sumatra, Indonesia

REVISION NO.

PAGE

DATE July 14, 2015


OF 8

STRETCHER DATA SHEET


1 ITEM NO.

2 SERVICE

Stretcher

NO. REQUIRED :

SET

DESIGN CRITERIA

3
4
5

1. Type

Stretcher fold or assembly type, Indoor Stored

2. Location

Manufacturing Standard

Stretcher type, rigid and light weigh

6
7
8
9

3. Design Feature

10

Shall be designed suitable for medical evacuation by helicopter or ambulance car

11

Shall be supplied with the folowing :

12
13
14

4. Containing items

- 4 side carrying handles

(note 1)

- Shoulder harness

15

- 4 patient restraint straps

16

- Removeable backboard

17

- Head/ neck brace

18

- Foot brace

19

- Brackets for wall mounting

20
21

5. Material

22

-Shell

High Density Polyethylene

23

-Frame / outer ring

Stainless Steel or Aluminium

International Orange for Shell

24
25

6. Colour

26
27

7. Test & Inspection

28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Notes
1. Not limited with listed follwing