1. DVD Contents
This dual-layer DVD includes the CCURE 9000 from Software House and the victor product in support of
American Dynamics and Unified deployments. The DVD also includes the supporting Services, Integration drivers,
and latest firmware for both products.
NOTE: The CCURE 9000 Server component is now named the victor Application Server.
CCURE 9000 Install components (victor Application Server and CCURE 9000 Client)
EULA.rtf End User License Agreement.
9000_2_40_Relnote_RN00107.pdf the CCURE 9000 v2.40 Release Notes file.
Quick Start Guide.pdf the Unified Installer Quick Start Guide.
Setup.exe Executable to launch the installation dashboard.
Bin folder containing supporting installers and support files for CCURE 9000 and victor products.
(Installers should be installed via the installation dashboard, not through individual install files.)
English folder with Manuals folder containing PDF (Portable Document Format) files for manuals.
LanguagePack folder containing the v2.40 Language Pack. The v2.40 Language Pack, included with this
release of CCURE 9000 v2.40, can be installed with CCURE 9000 v2.40 or higher and includes PDF
files for manuals.
Prerequisites folder containing prerequisite software requirements for CCURE 9000 and victor.
ThirdParty folder containing support files for CCURE Mobile handheld reader.
NOTE: The Intellex, Video Edge, and HDVR/Exacq video drivers are included with this 2.40 release.
RN- 00107
Visitor Management is a licensed feature for creating and managing visitor appointments natively within
CCURE 9000 when you do not require separately integrated third-party visitor management options. This
feature provides a digital replacement for paper-based visitor log books and can organize and track visits to your
facility more efficiently. CCURE 9000 Visitor Management includes single-/multi-visitor group scheduled
appointments, temporary credential issuance, individual visitor check-in/check-out, and host
e-mail notification of visitor arrivals. (For information, see the CCURE 9000 Visitor Management Guide.)
Temporary Credentials is a standard feature that now allows Credentials to be created in advance for general
re-use without being associated with specific personnel records. These Credentials can be assigned/unassigned
quickly for temporary issuance to visitors and can also serve as temporary replacement cards for employees who
misplaced or forgot their regular Credentials. (For information, see the Credentials chapter in the CCURE 9000
Personnel Configuration Guide.)
Carpool Antipassback is a standard feature that now allows you to manage iSTAR Areas for parking lot control.
This feature allows you to organize personnel into Carpool Groups permitted to park in designated Carpool Areas
and to move these Group members in/out of the Areas based on a drivers Credential. The feature also supports
the monitoring of vehicle counts for parking lot occupancy restrictions (For information, see the iSTAR Areas
chapter in the CCURE 9000 Areas and Zones Guide.)
Area Pass-through is a standard feature that now allows you to restrict the length of time that Personnel can
linger in an Area they entered before being required to exit. (For information, see the iSTAR Areas chapter in
the CCURE 9000 Areas and Zones Guide.)
Maintenance Mode is a standard feature that now allows you to limit the information that displays for Security
Objects in the CCURE 9000 database. This gives you the ability to manage and filter false alarms from normal
monitoring of security points or equipment that is being installed, tested, or serviced. Activity and/or Events from
Objects in Maintenance Mode are recorded and identified accordingly in the historical Journal. (For information,
see the Maintenance Mode chapter in the CCURE 9000 Hardware *Configuration Guide.)
Schlage support on iSTAR Ultra CCURE 9000 now supports Schlage Wireless Locks via PIM connectivity on
iSTAR Ultra GCM RS-485 ports. (For information, see the CCURE 9000 Hardware Configuration Guide.)
ICU Available from Administration Station CCURE 9000 now makes the iSTAR Configuration Utility (ICU)
available from the Administration Station Options and Tools Pane. (For information, see the CCURE 9000 System
Maintenance Guide.)
Pre-Admit Event Trigger CCURE 9000 now provides a new trigger value Pre-admit for the Admit Status
property. You can select this trigger value to activate a panel event for a valid Card swipe at an iSTAR door
before the door actually opens. (For information, see the Door chapter in the CCURE 9000 Hardware
Configuration Guide.)
View Preferences CCURE 9000 now supports filtering on Administration and Monitoring Station Dynamic
Views of Partitions and/or Security Objects that are in Maintenance Mode. This allows setting your working
environment so you only have to deal with certain data subsets. (For information, see the Dynamic Views
chapter in the CCURE 9000 Data Views Guide.)
RN- 00107
Operator Accounts and Privilege Enhancements CCURE 9000 now provides the following improvements for
managing Operators and Privileges:
Basic User Authentication with locally defined user names/password, including strong password rule
enforcementin addition to standard Windows Single Sign-On (SSO) domain authenticated operator
accounts.
Simplified management and categorization of Privileges within a tree view, which allows assigning and
removing single or group privileges in bulk.
Import and management of Operators with their respective Privilege Groups using XML and LDAP role-based
templates.
Support for Read-only Privileges, which allows Operators to access and view only those records.
(For information, see the Operator and Privilege chapters in the CCURE 9000 Software Configuration Guide.)
Journal and Audit Triggers Enhancements
Journal Triggers have been enhanced to include Event Message activation cause information. The
Monitoring Event Status screen now displays the reason a particular Event was pulsed by a Journal trigger.
You are now also able to configure an Event Action that sends email notification with a description of the
activation cause each time a Journal trigger is activated.
Audit Triggers have also been enhanced to allow you to define Event Triggers based on Audit Log
Messages.
(For information, see the Audit Trigger and Journal Trigger chapters in the CCURE 9000 Software
Configuration Guide.)
Personnel Enhancements CCURE 9000 now provides the following improvements for managing Personnel:
Credential Status Color the ability to use two new System Variables to set different background colors for
the Active and Expired Credential Status field on the Personnel Editor Credentials tab.
Extend Maximum Cards per Person the ability to assign more than five Credentials to a person using a new
System Variable that only counts Active and/or Expired Cards towards the maximum assignable Cards per
Person. Lost, stolen, and disabled Cards are excluded from the system Five-Card Limit.
Time Span of Expiration the ability to use an enhanced System Variable to define the default period of time
(in Days and Hours, as well as in Years) from a Credentials Activation Date until its Expiration. In addition,
you can now set an override of that default for a particular Personnel Type, use Personnel Date fields to
personalize Expiration Dates, and configure a unique Expiration Time Span for Individual Temporary
Credentials.
Create from Template the ability to easily select a template for creating a new Personnel record by using
the new context-menu command Create from Template on the Personnel Templates Dynamic View.
Image Capture and Import Facility the ability on the Personnel Image tab to either Capture a persons
portrait or to import it from a file if the new option on the CCURE ID Portrait Configuration dialog box,
Enable both device capture and import from file, is selected. (You no longer have to exit the Personnel
Image tab and return to CCURE ID Badge Setup each time to change the options.)
(For information, see the CCURE 9000 Personnel Configuration Guide and the System Variables chapter in the
CCURE 9000 System Maintenance Guide.)
Monitoring Station Enhancements CCURE 9000 now provides the following improvements for monitoring:
Emailing Content of Activity and Event Viewers the ability for Operators with the appropriate Privileges to
click a new Email icon and mail selected on-screen transactionsthus permitting speedy communication of
an incident to other CCURE 9000 system Personnel.
Explorer Bar the ability to customize the Explorer Bar in Application Layouts to personalize the display of
categories/Security Objects to better reflect the needs of your facility. You can select the categories to
display as defaults, re-name them, and also add and remove newly created categories and their included
Security Objects.
RN- 00107
Swipe and Show the option to view multiple Personnel portrait images at one time and switch views on the
flysingle/dual/quad/ carousel. You are also able to resize the images to your liking, add text overlays, and
set border colors that indicate access transaction status, such as Access Denied or Access Granted. (The
updated Swipe and Show functionality will co-exist on the system with the Legacy single-image Swipe and
Show and can be selected when you configure the Application Layout.)
(For information, see the Application Layout chapter in the CCURE 9000 Data Views Guide and the relevant
chapters in the CCURE 9000 Monitor Guide.)
Usability Enhancements CCURE 9000 now provides the following improvements for managing your security
system:
Copy, Paste, and Rename of iSTAR Clusters the ability to use new context menu commands to quickly
create an exact duplicate of a fully configured iSTAR Cluster or individual iSTAR Controller (including all their
child objects) with the fewest clicks and least configuring. You can also use the new Copy To/Paste From
commands to duplicate iSTAR Cluster/Controller configurations on other Partitions or systems.
(For information, see the Hardware Pane chapter in the CCURE 9000 Hardware Configuration Guide.)
Show Associations the ability to use a new context menu command to view the Security Objects associated
with the selected Object. (For more information, see the User Interfaces chapter in the CCURE 9000
Getting Started Guide.)
Monitor the ability to use a new context menu command on the Administration Station to display a realtime Activity Viewer and monitor the selected Security Object and any of its related child Objects. (For
information, see the User Interfaces chapter in the CCURE 9000 Getting Started Guide.)
User-defined Fields for Hardware/Video the ability to create User-defined fields for Hardware and Video
Objects from the Configuration Pane and display them on a new User-defined Fields tab on the
Controller, Door, Reader, Elevator, Input, Output, Video Camera, and Video Server Editors.
New Save Button allows you to save your configuration on the User-defined Fields editor and
continue editing.
Enumerated User-defined Field Type supports Progressive typing, a filtering method for matching
values to quickly search and retrieve items from long drop-down lists.
(For information, see the User-defined Fields chapter in the CCURE 9000 Software Configuration Guide.)
Dynamic View Enhancements CCURE 9000 now provides the following improvements for managing Dynamic
Views:
Add, Remove, and Resize Columns allows changes made to a Dynamic View while viewing to be saved so
that Dynamic Views can be re-opened with the last customized changes.
Dynamic View Grouping supports pre-configured grouping by types of Objects for certain Dynamic Views
to make it easier for you to find related items.
(For information, see the Dynamic Views chapter in the CCURE 9000 Data Views Guide.)
GPI Enhancements CCURE 9000 now provides a new General Purpose Dynamic Action for improved
integration that allows the configuring/passing of variables in data message content sent to third party devices.
In addition, extended ASCII codes are now supported, allowing you to enter raw Hex values from 00 to FF. (For
information, see the CCURE 9000 General Purpose Interface Configuration Guide.)
For support information for Operating Systems, DBMSs, and SQL Server Collations, see Table 1, Table 2, and
Table 3 respectively.
NOTE: There are limitations on full client support for 64-bit.
RN- 00107
RN- 00107
Server or Client
server or client
server or client
server or client
server or client
server or client
server or client
server or client
server or client
Server or Client
server or client
server or client
server or client
server or client
server or client
server or client
server or client
server or client
Server or Client
client only
client only
client only
client only
server or client
server or client
server or client
server or client
Server or Client
client only
client only
client only
client only
server or client
server or client
server or client
server or client
Server or Client
server only
server only
server or client
server or client
Client
Windows 7 Professional
Windows 7 Enterprise
Windows 8.1 Professional
Windows 8.1Enterprise
Windows Server 2008 R2 Standard
Windows Server 2008 R2 Enterprise
Supported Version
32-bit, 64-bit, SP1 or later
32-bit, 64-bit, SP1 or later
32-bit, 64-bit
32-bit, 64-bit
64-bit, SP1 or later
64-bit, SP1 or later
Client
client only
client only
client only
client only
client only
client only
Supported Version
10.50.1600.1 RTM (32- and 64-bit)
10.50.1600.1 (32- and 64-bit)
10.50.1600.1 (32- and 64-bit)
SP1 or later (32- and 64-bit)
SP1 or later (32- and 64-bit)
SP1 or later (32- and 64-bit)
(32- and 64-bit)
(32- and 64-bit)
(32- and 64-bit)
Supported Version
10.50.1600.1 (32- and 64-bit)
10.50.1600.1 (32- and 64-bit)
SP1 or later (32- and 64-bit)
(64-bit)
(64-bit)
(64-bit)
RN- 00107
4.1.4 Required Hard Drive Space for Upgrading Enterprise Architecture Systems
Upgrading the MAS and SAS requires a significant amount of hard drive space. Please ensure that SQL Server has
at least 100GB of available hard drive before upgrading to v2.40.
4.1.5 Upgrading MAS before its SAS
It is required that when you upgrade your MAS and SAS systems, you first upgrade the MAS and then upgrade
the SAS systems to the same version. Otherwiseif you upgrade your SAS systems first, those SASes will require
another full restart once youve upgraded the MAS.
RN- 00107
RN- 00107
Very large imports can cause the MAS performance to significantly degrade when synching with the SAS.
Importing personnel records with attached documents and/or images can use significant amounts of
memory during replication. Software House recommends you keep imports down to a total of 400MB,
including both Image and Document data.
Example:
3000 personnel with 500KB Documents for each personnel record = 1.5GB of memory to process.
RN- 00107
10
RN- 00107
RN- 00107
11
The following list includes some of the third-party products compatible with CCURE 9000 Version 2.40.
Table 4: Third-Party Hardware
Equipment Type
Vendor
Model
Latest Supported Version
____________________________________________________________________________________
Digital Video
American Dynamics
Intellex
5.0
Management System
____________________________________________________________________________________
Digital Video
American Dynamics
NVR
4.6
Management System
____________________________________________________________________________________
Digital Video
American Dynamics
HDVR
1.7
Management System
2.1
2.2
____________________________________________________________________________________
Digital Video
Exacq
Exacq
5.8.4.49984
Management System
____________________________________________________________________________________
Bioscrypt
Bioscrypt
V-SMART I CLASS
7.5K
Readers
Soft. 5.50
V-STATION I CLASS
7.30
Soft. 5.51
____________________________________________________________________________________
Schlage Electronic
Schlage
AD-400/401
AD.A.60
Locks
AD-300/301
AD.A.60
____________________________________________________________________________________
Assa Abloy
Assa Abloy
Aperio
Hub: 6.2.28176
Electronic Locks
____________________________________________________________________________________
Signature Capture
Topaz
T-S261-B
3.0.3
Topaz USB
T-S261-HSB
4.4.0
PenWare 100
PW100
4.5.0
____________________________________________________________________________________
USB Badging Cameras
Video Associates
Val Cam
6.1.76.00
VA 3 USB Camera
7.7
Videology
24C7.38USB
9.0
20K758USB
TWAIN
2.1.18
____________________________________________________________________________________
IP Cameras
AXIS
2400/2401
2.33
____________________________________________________________________________________
Badging Printers
Fargo
HDP 5000
2.7.0.13
Fargo
DTC 4500E
2.1.0.3.2
Magicard
Prima 4
8.01
Magicard
Pronto
2.0.13.0
Magicard
Rio Pro
2.0.13.0
Omnikey
Ecoder
2.18.0.0
_____________________________________________________________________________________
Smart Card Device
SCM Microsystems
SDI010
5.21
_____________________________________________________________________________________
CCURE Mobile
Datastrip
DSV 11SG
1.0.63.46
_____________________________________________________________________________________
12
RN- 00107
The following list includes some of the third-party software compatible with CCURE 9000 Version 2.40.
Table 5: Third-Party Software
Company
Product
Latest Supported Version
__________________________________________________________________________________
Data Dynamics
Active Reports
6.2.3681
__________________________________________________________________________________
American Dynamics
Intellex API
5.00.74.189
__________________________________________________________________________________
Flexera
FLEXNet Publisher
11.10.1
__________________________________________________________________________________
LEAD Technologies
LEADTOOLS
14.5.0.68
__________________________________________________________________________________
Infragistics
Infragistics
14.1
__________________________________________________________________________________
Microsoft
.NET
4.5
3.5 required if installing SQL Server
Windows Installer
4.5
MFC Runtime
9.0 SP1,10.0 SP1, and 11.0
Silverlight
5.0.61118.0
WIX
3.7
__________________________________________________________________________________
Sequiter Inc
CodeBase
6.5
__________________________________________________________________________________
Stratus
everRun MX
6.x
everRun Enterprise
7.2
__________________________________________________________________________________
Stunnel
Stunnel
5.00
__________________________________________________________________________________
The OpenSSL Project
OpenSSL
1.0.1h
__________________________________________________________________________________
The following list includes the firmware versions for the controllers for CCURE 9000 Version 2.40.
Table 6: Firmware for Tyco Security Products Controllers
Controller
Latest Supported Version
__________________________________________________________________________________
iSTAR Classic
4.4.C
__________________________________________________________________________________
iSTAR Edge, eX, Ultra
6.2.0
__________________________________________________________________________________
iSTAR Pro
5.2.9
__________________________________________________________________________________
apC, apC/8x, apC/L
x.7ZF
__________________________________________________________________________________
9. SPARs Fixed
SPAR # 27475 You can now view Personnel records with a read-only Privilege.
SPAR # 32754 The Access to Common Objects Privilege no longer gives Operators access to the Options &
Tools objects. (There is now a separate Access to Options and Tools Privilege.)
SPAR # 51828 You can now add multiple Privileges to an Operator at one time (in bulk) and have the Always
Schedule applied to all the Privileges by default.
SPAR # 52548 The Verify and Delete conflicts function has been removed from the Sync Conflicts dialog box
since the system now deletes Sync conflicts automatically.
RN- 00107
13
SPAR # 110726 The system now allows you to use a period (.) in an Object name when filtering to select from
drop-down listfor example, sal.1.
SPAR # 112465 In an Enterprise System, the DB restore integrity check field now resets itself correctly.
SPAR # 115943 The Administration or Monitoring Stations no longer crash if the database has two different
state images for a monitor property value for an Object. (The second state image is not used.)
SPAR # 122726 CCURE Mobile no longer receives intermittent "Access forbidden" message for no apparent
reason.
SPAR # 122854 Set Property is no longer slow when used to edit Personnel records.
SPAR # 123160 Enumerated List values are now sorted alpha-numerically when the field name is used as
criteria in a Query.
SPAR # 123501 Performing a load server configuration on multiple CCURE Mobile units simultaneously no
longer causes undesirable mobile connectivity and IIS behavior.
SPAR # 125205 The Audit Log no longer displays a Dash (-) instead of the Object name when a Door is removed
from a Clearance. The name of both the Door and the Schedule now display.
SPAR # 127764 Printing a Badge no longer sporadically causes disabled Credentials to be re-enabled.
SPAR # 132321 You can now arm/ disarm generic Input Groups that include both iSTAR and apC Inputs when
using a Custom Privilege.
SPAR # 132753 A null value no longer causes CrossFire to disconnect from the iSTAR driver.
SPAR # 133815 The Privilege level of the domain system account can no longer be modified by any operator
when the CrossFire Service is executing.
SPAR # 137106 ODBC Import no longer occasionally re-imports the entire source database even though nothing
actually changed in the source table.
SPAR # 138244 You are now able to grace a global person when using a custom privilege and connected to the
MAS.
SPAR # 138271 Complex Queries now execute OR expressions correctly and return correct results, whether
the Query is run alone or for its related Report.
SPAR # 138382 The diagnostics that trace operator logins now return the names and privileges of Operators
logging in and out as well as the number in cache.
SPAR # 139861 Operators are no longer prevented from removing Custom Clearances even though they have
the Privilege to do so.
SPAR # 140559 Leading and trailing spaces are no longer saved in Personnel record Name fields, and as a result,
no longer cause skewed results when Personnel records are sorted by name in a Dynamic View.
SPAR # 140599 When you save a newly created Personnel record by clicking the Save and New button and the
empty Personnel Editor opens for you to create a new record, the Badge Layout field on the Credentials tab is
now available.
SPAR # 141015 Upgrades no longer fail if either of the fields in the System Variables Customer Support
categoryContact Information and Contact Person Email Address (labeled Email Address prior to
version 2.30)has more than 100 characters. (Note: the field is truncated at 100 characters.)
SPAR # 142544 The Journal Sync to the MAS no longer fails when there are more than one million records or
the tracking table is empty.
SPAR # 142548 Inputs that are armed by default no longer become disarmed after a restart or a patch install.
SPAR # 142955 Events that sometimes were not activating properly now activate as they should.
SPAR # 144053 Orphaned iSTAR Boards no longer cause download problem for Controllers.
SPAR # 144249 You can now change the Application Server name.
SPAR # 144252 The journal and audit databases in upgraded SASes no longer have incorrect triggers for
synchronization.
SPAR # 145721 Events now work with activate and deactivate alarm CCTV strings whether the parameter values
are before or after alarm number parameter.
14
RN- 00107
SPAR # 146707 The Display Map button on the Event Details tab and the Quick Action button on the Monitoring
Station Event Viewer now work properly.
SPAR # 147179 Troubleshooting synchronization conflicts is now easier because the Object Type is now
included in the Dynamic View as well as the Object ID.
SPAR # 147584 In an Enterprise environment, the system now saves the data entered into a Date field when it
is moved to the Personnel Editor Credential tab.
SPAR # 147946 The system now provides options for Admit Visitor and Reject Visitor when you are
configuring a Door Trigger for Admit Status.
SPAR # 147947 The system now properly updates the names of the Elevator buttons when you change the
name of an Elevator.
SPAR # 148276 The card numbers for Credentials deleted from the Credential Dynamic View are now properly
deleted from the iSTAR Personnel database.
SPAR # 148632 The second Door in a Schlage AD300 chain now unlocks properly.
SPAR # 149387 You now receive similar Warning messages and information when you perform a Remove
Personnel from Area action whether from the Administration application, Monitoring Station, or via an Event.
SPAR # 150653 The driver no longer crashes when a Host Event with a recurring schedule, hourly for example,
activates panel hardware, as in unlocking apC and iSTAR Doors.
SPAR # 150706 You are now able to edit the Time in the Custom Clearance Activation and Expiration fields.
SPAR # 151777 HDVR cameras now come back online automatically after losing network connections.
SPAR # 151832 You can now send an email message activated by an Event when using an Email Server that
requires authentication.
SPAR # 152137 A Remote Client no longer takes up to 10 minutes to connect.
SPAR # 153679 Guard Tours no longer time out early, and therefore no longer cause "not completed on time"
and "completed late" messages to display before the Tour actually ends.
The CCURE 9000 Installation and Upgrade Guide includes step-by-step instructions for upgrading your CCURE
9000 system. The upgrade chapter explains the steps you need to take prior to upgrading, the database updates
that are performed when you upgrade, and the tasks you need to perform after the upgrade is completed. Please
refer to this guide for information. You can upgrade to CCURE 9000 v2.40 directly from the following earlier
versions:
V2.20
V2.30
V2.30 R2
CAUTION: Before upgrading to CCURE 9000 v2.40, see Important Notes on Page 1 of these Release Notes.
In addition, if you currently have the CCURE 9000 Language Pack installed, see Item 5.16 on Page 11.
Be aware that upgrading removes the existing firmware files (<INSTALLDIR>Tyco\CrossFire\ServerComponents\
apC and istar) while adding the new firmware versions. If you need to keep your existing firmware, save the files
elsewhere before you upgrade to v2.40. Otherwise, you will have to re-download these files from the Software
House web site.
10.1 CCURE + victor Server Databases May Expand During Upgrade
During an upgrade, the CCURE + victor Server application databases may grow in size due to index re-creation
and upgrade of the database tables. Depending on the size of the databases beforehand, the size may expand by
up to 10GB. Thus, you should ensure that ample disk space is available before you begin.
10.2 Upgrade May Freeze with Out-of-Disk Space Error
During an upgrade, a message may inform you that there is not enough disk space available.
Workaround: Add more disk space on an existing/new drive and run the upgrade again.
RN- 00107
15
10.3 Error Message During CCURE 9000 Client Upgrade from v2.20
When upgrading a CCURE 9000 Client from v2.20, the following error message sometimes appears: Error:
Configuration registry key is invalid. You can ignore this error message by clicking OK. The upgrade then
continues and completes successfully.
10.4 Post-Upgrade Steps for CCURE 9000 v2.40 System on Custom (Non-default) Path
If you are upgrading a system in a custom (non-default) location, once the upgrade to v2.40 is completed, you
must verify that the System Variable paths for Import, Export, and Database Backup are correct.
10.5 Exported Objects into External XML Documents
If you have exported objects into external XML documents from previous versions of CCURE 9000, you may not
be able to re-import them directly into CCURE 9000 v2.40. Object definitions in the database can change from
version to version, so the import may fail or the imported object may not work correctly in CCURE 9000 v2.40.
Workaround: If you have any valuable XML documents generated by Data Export in a prior version of CCURE
9000, you should do the following prior to upgrading CCURE 9000 to v2.40:
1. Re-Import the XML documents.
2. Upgrade to v2.40.
3. Export the Objects again.
10.6 Upgrading BIRS from v2.20 to v2.40
If you have been using the BIRS reporting product from Professional Services and are planning to upgrade to
CCURE 9000 v2.40, you must perform some manual steps before you upgrade. For detailed information, see the
BIRS Application Note #8200-1068-01 A0 in Program Files(x86)\Tyco\CrossFire\Tools\UpdateBIRS.
10.7 SDK Connected Program Drivers
10.7.1 SDK Connected Program Drivers and CCURE 9000 Upgrade
BEFORE UPGRADING CCURE 9000: If you licensed any of the SDK Connected Program drivers with a previous
release, check the Software House web site (Home>Support>Software House Connected>
Compatibility Matrix http://www.swhouse.com/support/SWH_Connected_Compatibility_Matrix.aspx) to
confirm that your integration is compatible with v2.40 BEFORE YOU UPGRADE.
Contact the distributor of the Connected Program driver to get your CCURE 9000 v2.40 compatible driver.
NOTE: Client Auto-Update does not update clients with new versions of a Connected Program Driver product;
you must perform Client updates for these products manually at each client.
10.7.2 Uninstalling SDK Connected Program Drivers
If you have a Connected Program Integration from a previous release that you do not intend to upgrade and wish
to uninstall, you must uninstall it before you upgrade your CCURE 9000 to v2.40. If you upgrade to v2.40 and
then try to uninstall, the uninstall may fail.
16
RN- 00107
11.3 Installation Completes on Longer-than-15-Character Name Computer But Clients Do Not Connect
If you install CCURE 9000 on a computer with a name longer than 15 characters, the following error message
displays: The NetBIOS name is limited to 15 characters. You can continue the install, but the system name will
be truncated. Consequently, Clients will be unable to log in to CCURE 9000.
Workaround: Change the computer name to match the 15-character truncated version.
11.4 Installation Completes on Windows 7 system without SP 1 Prerequisite Installed
If you are installing CCURE 9000 on a Windows 7 system without the SP 1 prerequisite installed, the process still
continues and completes. However, before you use CCURE 9000, you should install SP1.
11.5 Post-Install Steps for CCURE 9000 v2.40 System on Custom (Non-default) Path
If you are installing CCURE 9000 v2.40 in a custom (non-default) location, you should verify that the System
Variable paths for Import, Export, and Database Backup are correct once the install is complete.
11.6 Services/Server Components Manual Start
After installing CCURE 9000 v2.40, you must run the Server Configuration Application (Start>All Programs>
Tyco>Server Configuration Application) one time to start the CrossFire Framework and CrossFire Server
Component Framework Services. (You cannot access CCURE 9000 functions until you start these services.)
You also need to enable and start the Extension Service (Hardware Driver) for each type of controller, video, or
network component to be used on the server. (The Extension Services [Drivers] are not automatically started by
default because enabling drivers for devices that are not used can affect system performance. In addition,
starting them automatically would trigger a download for apC and iSTAR controllers.) See the CCURE 9000
Installation and Upgrade Guide on the product DVD for specific instructions. You can view the status of these
drivers from Windows Services, but should not configure them to start automatically from there; startup is
managed by the CrossFire Server Component Framework Service.
11.7 victor Temporary License Expiration May Cause CCURE 9000 Licensed Video Drivers to Not Work
If you install a CCURE 9000 + victor Unified system but do not obtain a permanent license for victor, CCURE
9000 Video drivers may stop working when the victor temporary license expires.
Workaround:
1. Either obtain a permanent victor license or remove the victor temporary license.
2. Edit, disable, and then save each Video Server on the CCURE 9000 Administration Station.
3. Edit, enable, and save each Video Server to restore the connection with each server.
11.8 Installing CCURE Go Web Service and CCURE 9000 Web Client
11.8.1 IP Address Requirements for CCURE Go Install
You should install the CCURE Go Web Service application either on a system with a fixed IP address or on a
system that cannot switch from one IP address to another by a simple reboot. Since CCURE Go has no way of
knowing that the IP address has changed, it cannot distinguish a server IP address change from the service on the
server stopping or the server being shut down.
11.8.2 IIS Version Prerequisite for CCURE Go Install
If the required IIS version for the CCURE GO Web Service is not installed as a prerequisite, an error message
appears when the CCURE Go Web Service installation actually begins, rather than on the final prerequisite
review screen earlier in the process.
RN- 00107
17
11.8.3 Installing Language Pack for CCURE Go and CCURE 9000 Web Client
If you install either the CCURE Go Web Service or the CCURE 9000 Web Client on a computer that does not
have the CCURE 9000 client on it, you will not be able to install the language pack. Consequently, you will not
have a fully translated product.
Workaround:
1. Install the CCURE 9000 client.
2. Install the language pack on the computer with the CCURE Go Web Service/ CCURE 9000 Web Client.
11.8.4 CCURE Go Web Service Installation Not Supported on MAS
You are not prevented from installing the CCURE Go Web Service on a MAS system that is an IIS server.
However, you should be aware that this configuration is not supported and the CCURE 9000 MAS license does
not allow it.
11.9 Uninstalling CCURE 9000 Fails on Window Server 2012 with Remote SQL if .NET 3.5 Not Enabled
If you try to uninstall CCURE 9000 from a Windows Server 2012 system that uses a remote SQL database and
does not have .NET 3.5 installed locally, the following error message displays: There is a problem with this
Windows installer package. A program did not finish, etc."
Workaround:
1. Click OK to terminate the uninstall process.
2. Enable the .NET 3.5 feature.
3. Re-start the uninstall process.
The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks
is strictly prohibited and Tyco will aggressively enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal
prosecution wherever necessary. All trademarks not owned by Tyco are the property of their respective owners, and are used with permission or allowed
under applicable laws.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features.
Availability varies by region; contact your sales representative.
2015 Tyco Security Products. All Rights Reserved
18