1.

SERIES MOTOR highest torque


2. FILTER - convert pulsating to unidirectional forms
3. HOOK-ON WATTMETER measure w/t of electrical machines
4. DIMMER reduce brightness of incandescent lamps
5. SOFTWARE made calculation easier
6. FH-TRANSFORMER classified according to cooling system except. (FOA FDW OA)
7. SUPERPOSITION METHOD used with ckt with 2 or more voltage sources
8. 4 number of layers for 13.8 Kv
9. MCS latest trend in control of powerplant (SCADA REMOTE DIGITAL)
10. DISCONNECT SWITCH MANNER it breaks the circuit except top
11. Letters designated to cooling of transformers (O,L,G) except X
12. IEC standard for coolant circulation of transfoemers (N F D) except A
13. OIL CONSERVATION purpose of conservator tank of transformers
14. BIL factory test on transformers
15. CTs classification according to construction (wound primary, through a bar,
window or bushing) except auxiliary
16. Cores of current transformers classified to metering and PROTECTION
17. Connection of CT when using differential relay for delta-wye. WYE-DELTA
18. LAOAG ILOCOS NORTE area most frequented by thunderstorm
19. FIELD HV electrical testing for machines are generally classified except(factory,
proof , maintenance)
20. WHEATSTONE BRIDGE used to measure winding resistance of power
transformers
21. TWO POINT simplest method for measuring ground resistance
22. HFERMI measure earth resistance
23. SR51 famous multi-amp relay test
24. DPWH-96-006E form for final electrical inspection
25. 12.4 kv/ft voltage gradiant of lighting at half mile horizontal distance
26. GROUNDING MECHANISM 0 used to discharge static charges on HV
27. JUNGUER other name for nickel cadmium battery
28. FORWARD BREAK OVER voltage applied to SCRs which switches to conduct w/o
bias
29. 10 YEARS frequency of checking undercover power transformers
30. BURNISHER clean silver coaled contacts of relays
31. Anthracite coal w/ 90-95% carbon buns w/ no smoke
32. BALATA elastic grum from Venezuela used for insulation
33. BANJO in pole line construction for tightening a wire
34. BARAD unit of pressure in cgs
35. BELT CIRCUIT circuit for electric lighting connected in series with extended loop
rather than parallel lines
36. BURETITIZE method of protection wood poles from decay by saturating it with
zinc chloride
37. CONSNEQUENT poles occurring in a dyanamo oat points else where other than
at pole pieces
38. CONVOLUTIONS loops in a coil of wire
39. CYRNOSCOPE device which indicates the presence of electric waves
40. ELECTREPETER used to change direction of electric currend
41. ENDOSCOPE lamp used to illimunate internal cautig of human body
42. ENTREFER open space ebetween the face of the pole piece of a dynamo and the
surface of the armature
43. EPSTEIN HYSTERESIS TESTER use to measure hysteresis and eddy current losses
in conjunction with an AC wattmeter
44. Zwitter ions ions which are positive and negative charge at the same time
45. KAPLAN reactor type turbine with adjustable blades suitable for run off rivers
with variable head and flow
46. .285 SG of fully charged lead acid battery at 80F
47. CHORRITTEN common commercial name of synthetic insulation oil except this
(chlorextor,inerten , ppyranol)
48. CO2 extinguishing agent for fires due to electrical

49. 140% - setting for overload protection of hermetic motors


50. 3R NEMA code for enclosures that are weather proof
51. 50A lowest ampere frame available for modelled case of CB
52. PLATINUM IRON common thermocouples used with potentiometer except
this(iron-constantan, copper constantan, pronel-alumel)
53. 105C thermal limit of class A
54. DISSIPATION FACTOR R/X
55. PILOT small transformer set at any point in an AC system to indicate to the
central station the pressure at that point
56. TRANSFORMER ON THE POLE most common outdoor type Mpe electric
substation
57. LITZENDRANT multi stranded wire0having transpositions to reduce skin effect
58. FLUVIOGRAPH records automatically the water level on river or dam
59. CLYCLOMETER register number of rev made by motors or alternatios
60. 20% - spare breakers installed on panel board
61. RED COLOR code for the three phase hot conductor
62. N- used to purge sealed type power transformer
63. ELECTRIC POWER SUBSTATION can be classified except grounding (function,
service control)
64. SHADED POLE can be reversed by physically inverting the position of the rotor
65. ENGLAND Michael faraday
66. ELECTRICAL MEASURING INSTRUMENT except electrodynamics
67. Residential,commercial,VA 200VA
68. GPR ground potential rise
69. Bedrock soil 10,000
70. CAPACITORS, IMPROVED PF- shunt
71. INDUCTION MOTORS , D, K lesser
72. CHARGING OF SECONDARY BATTERY trickle charging
73. Voltage regulation, determination except ANSI METHOD
74. Switching equipment separate, ISOLATED PHASE
75. Electrolyte , nickel iron POTASSIUM HYDRIDE
76. Parallel synchronous gen NONE OF THE ABOVE
77. Union skin 50% OF THE CONTACT AREA
78. Regreasing 50 to 100 HP ONCE EVER 4 MOS.
79. Alter voltage in DC MG SET
80. AC superior to DC FLEXIBILITY IN CHANGING VOLTAGE
81. Error , annalog measuring PARALLAX
82. Voltmeter, upper element defective 9,7
83. Motion electrical current speed CREEPING
84. Both positive and negative POSITION
85. R, cube, diagonal opposite 5/6 R
86. Ammeter, switches ,part ,, panel board copper third
87. DC system , transit trains 750 volts
88. DC system powerplants and substations 125 volts
89. Mix acid to water , electrolyte MIX ACID TO WATER
90. Asymmetrical, symmetrical X1.73
91. Windows 1000mm
92. SLD frontage of switch 0 miniature bus
93. Arrangement, free parallax semi- circular type
94. Modern road makers DELIMEATORS
95. Reduction capacity delta-delta 42.2%
96. Fasten, tray supports RAM set
97. Protect transformers, pressure bucholz relay
98. De-ion contact developed by WESTINGHOUSE
99. Sealed type transformer , purge NITROGEN
100.
Polarity , transformer, additive , subtractive INDUCTIVE KICK
101.
HV transmission line , safer PEOPLE WILL STAY AWAY
102.
Sag except EARTHQUAKE
103.
ACSR 266,000 18/1 WAXWING

104.
105.
106.
107.
108.
109.
110.
111.
112.
113.
114.
115.
116.
117.
118.

119.

Sparing of poles VERTICAL LOADING OF POLES


Ratio of actual light COEFFICIENT OF UTILIZATION
Hysteresis loss , reduced USING GRADIENT SILICON STEEL
No-load current , magnetic flux EXCITING
Windind, SM, start,rated , speed, - AMORTISSEU
Latest CLASS E
Sizes, ANSI/NEMA bigger
T and pi combination 0 stenmentz equivalent ckt.
Overload series fault
Least prevalent LLL fault
Rule of thumb 1000A/in^2
Only + and sequence LL fault
Swinging panel, avoid parallax syndroscope
Spot testing 1 minute
PI, class B 1.5
% fill of conduits , NEC- <40%