Sei sulla pagina 1di 2

STS100-STS300

Single and Three-phase


Static Transfer Switches

Product Snapshot
Technology: SCR, Microprocessor
Rating:

25-100A 1Ph (STS100)

100-3000A 3Ph (STS300)

Voltage:

110-270 Vac 1Ph

208/380/400/415/440/480 Vac 3Ph

Frequency: 50/60 Hz

In mission-critical environments such as data


centers, telecommunication installations, ISPs, and
government facilities, the reliable and seamless
transfer of power is fundamental to meeting
absolute uptime requirements.
The STS100 and STS300 systems are static
switches controlled by thyristor modules to feed
critical AC loads without interruption.

characteristics of the input voltage. If the input lines


are synchronized, the exchange from one line to
the other is less than 4 ms.
The basic STS100 is a single phase product,
mounted in a 19 (9 units) rack. The STS300 is a
three phase version (free standing cabinet). For
maintenance operations Units include a double
manual by-pass. Other configurations can be
supplied according to technical requirements.

Units switch between different AC input lines


according to priority criteria and technical

Main Features

4 Continuous monitoring

Main Options
-

System mimic panel for visual

of sources (voltage and

indication with LEDs and

frequency)

audible alarm

4 Automatic instantaneous
transfers without cross
connection of sources

4 Automatic retransfer
4 Manual Transfer capability
4 Redundant (3x3) internal
power distribution in all
system control boards

4 Enhanced monitoring and


diagnostics enhance system
availability by enabling quick
response to events:
-

RS232 and RS-485 interface

System graphic control panel

Alarm, data history and event

with Modbus protocol

logs

Metering: kVA, kW, CF,


PF, current, voltage, and
frequency

4 Short circuit transfer inhibit


4 Dual maintenance manual
bypass protected to prevent
cross-connection

4 True oversized neutral (2 In)


4 Programmable alarm relay
contacts

4 Front access to all power


components

4 Bottom and top cable entry


4 Redundant cooling with
monitored fans

4 1-phase 2-pole configuration


3-phase 4-pole configuration

4 Plug-in circuit breakers


4 Operation without neutral
4 Different protection degrees
and painting

4 Isolation transformer
4 Output distribution panels
4 Modbus port for STS100
4 Panel Builder Kits
Typical Applications

4Data Centers
4Internet Providers
4Industrial Facilities
4Process Control Applications
4Utilities
4Telecommunications

BORRI STS100-STS300
STS300 Technical specifications
Rating
Dimensions WxHxD
Weight
Input/Output connection

100A
820x1475x835
265
Hardwired

250A
820x1475x835
290
Hardwired

400A
820x1475x835
305
Hardwired

630A
1220x1900x860
615
Hardwired

800A
1220x1900x860
660
Hardwired

Operational
Nominal input voltage (Vac)
Source voltage range
Frequency
Transfer time and mode
Efficiency
Load power factor
THD current f.back from load
Standard Options
Options on request

208/380/400/415/440/480 Vac three phase


up to 20%, 10% factory adjusted
50/60 Hz
<=4ms, Break before Make (avoiding fault propagation)
>=99%
1 to 0,3
unlimited
3-phase 4-pole configuration, Plug-in circuit breakers, operation without neutral, Panel Builder versions
Output Distribution Panels, Isolation Transformer, Special IP Rating, Paint Finish

User interface
Front Display
Communication ports

Graphical LCD display showing status, meters, alarms and event log, mimic with leds

RS232, RS485, Modbus, 9 programmable inputs, 5 (+9 optional) programmable output relays,
additional relays (optional)

Environmental
Operating temperature
Relative humidity
Altitude
Audible noise at 1 meter (dBA)

STS100 Technical specifications


0C +40C
095% non-condensing
<1000 m
<65 dBA (According to ISO 3747)

Rating

25A

Dimensions WxHxD

rack 19, 9u

50A

Weight

25

Input/Otput connection

Hardwired

25

80A

100A

28

28

Nominal input voltage (Vac) 110/115/120/220/230/240/277 Vac single phase

Certification
Markings
Safety
EMC
Low voltage assemblies
Semiconductor convertors
Degree of protection

CE
EN 50178
EN61000-6-4, EN61000-6-2
IEC 60439-1, 60439-2, 60439-3
IEC 60146-1-1, 60146-1-3, 60146-2
IEC 60529

Source voltage range

up to 20%, 10% factory adjusted

Frequency

50/60 Hz

Transfer time and mode

<=4ms, Break before Make (avoiding fault propagation)

Efficiency

>=99%; >=98% 2 pole

Load power factor

1 to 0.3 lag

Option

2-pole configuration

Front Panel

mimic with leds, output voltage & current meters

Optional ports

RS232, RS485, Modbus, additional relays

STS300 HC Series, 1000-3000A


Includes the same features as the
STS300 range but with higher power
handling. The HC Series is available
in either kit form for Panel Builders or
assembled into factory enclosures, in
the following Ratings: 1000A, 1250A,
1600A, 2000A, 3000A.

BORRI S.p.A.

STS Family

Head Office & Factory


Via 8 Marzo, 2 - 52012 Bibbiena (Arezzo)

Ptinted in Italy - 2007 - Borri s.p.a.

Tel. +39-0575-5351 - Fax +39-0575-561438

The information contained


in this publication is subject
to variations without notice.

www.borri.it

Potrebbero piacerti anche