49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
** ON A/C ALL
TASK 49-90-00-600-007-A
Check Oil Level and Replenish (131-9(A))
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN
YOU DO THE MAINTENANCE TASK(S).
WARNING:
CAUTION:
1.
B.
QTY
1
1
AR
DESIGNATION
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
CONTAINER 3 L(3/4 USGAL)
SAFETY CLIP - CIRCUIT BREAKER
ZONE DESCRIPTION
C. Referenced Information
REFERENCE
(Ref. 24-42-00-861-001-A).
(Ref. 24-42-00-862-001-A).
(Ref. 29-00-00-864-001-A).
DESIGNATION
Energize the Ground Service Network from the External Power
De-energize the Ground Service Network Supplied from the External
Power
Put the Related Hydraulic System in the Depressurized Configuration
before Maintenance Action
Oil Change (Drain Procedure) (131-9(A))
Oil Change (Top-Off Procedure) (131-9(A))
Brand/Type Oil Change (Flush Procedure) (131-(A))
Open the APU Doors for Access
Close the APU Doors after Access
Low-Oil Level (131-9(A))
(Ref. 49-90-00-600-008-A).
(Ref. 49-90-00-600-008-A-01).
(Ref. 49-90-00-600-008-A-02).
(Ref. 52-41-00-010-001-A).
(Ref. 52-41-00-410-001-A).
Ref. TSM 49-00-81-810-867
Oil Servicing SHEET 1
Guideline for the Oil Consumption of the APU 131-9(A) in Service SHEET 1
Page 1 of 7
Customer : AXM
Manual : AMM
Type : A318/A319/A320/A321
Selected applicability : 228-228
Rev. Date : Feb 01, 2016
49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
FR80
Z315
Z316
FR84
FULL
1 LT
ADD
FULL
1 LT
APU
RUN
APU
OFF
LUBE MODULE
FILTERS
316AR
315AL
FILLER CAP
OIL SIGHT
GLASS
DRAIN PLUG/MAGNETIC
CHIP COLLECTOR
N_MM_499000_3_PAM0_01_00
Page 2 of 7
0.0
2
(0.42)
4
(0.84)
6
(1.25)
8
(1.67)
10
(2.07)
12
(2.51)
20
30
50
60
70
40
0.099qt/hr
(93cc/hr)
80
90
NOTE:
10
0.196qt/hr
(185cc/hr)
100
0.0
1.9
3.8
5.7
7.6
9.4
11.4
13.2
15.1
16
(3.32)
14
(2.9)
17.0
18
(3.74)
18.9
LITERS
20
(4.16)
QUARTS
(US GALLONS)
NOTE:
CAUTION:
Customer : AXM
Manual : AMM
Type : A318/A319/A320/A321
Selected applicability : 228-228
Rev. Date : Feb 01, 2016
49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
N_MM_499000_3_PCM0_01_00
Page 3 of 7
Customer : AXM
Manual : AMM
Type : A318/A319/A320/A321
Selected applicability : 228-228
Rev. Date : Feb 01, 2016
49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
3.
Job Set-up
Subtask 49-90-00-860-060-A
A.
Subtask 49-90-00-865-062-A
B.
DESIGNATION
APU/APU/CTL
APU/ECB/SPLY
FIN
2KD
1KD
LOCATION
L42
L41
Subtask 49-90-00-010-056-A
C.
Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the APU access door
315AL and 316AR.
(2) Open the APU access doors 315AL, 316AR (Ref. AMM TASK 52-41-00-010-001) .
(3) Set the LIGHT control SW 11LJ to the ON position.
Subtask 49-90-00-869-052-A
D.
AMBIENT
TEMP. MINIMUM
-54C (-65F)
-54C (-65F)
AMBIENT TEMP.
MAXIMUM
54C (130F)
54C (130F)
AMBIENT
TEMP. MINIMUM
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
-40C (-40F)
AMBIENT TEMP.
MAXIMUM
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
54C (130F)
Page 4 of 7
Customer : AXM
Manual : AMM
Type : A318/A319/A320/A321
Selected applicability : 228-228
Rev. Date : Feb 01, 2016
49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
AMBIENT
TEMP. MINIMUM
-40C (-40F)
-40C (-40F)
AMBIENT TEMP.
MAXIMUM
54C (130F)
54C (130F)
AMBIENT
TEMP. MINIMUM
-54C (-65F)
-54C (-65F)
AMBIENT TEMP.
MAXIMUM
54C (130F)
54C (130F)
AMBIENT
TEMP. MINIMUM
-40C (-40F)
-40C (-40F)
-40C (-40F)
AMBIENT TEMP.
MAXIMUM
54C (130F)
54C (130F)
54C (130F)
AMBIENT
TEMP. MINIMUM
-40C (-40F)
AMBIENT TEMP.
MAXIMUM
54C (130F)
WARNING:
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN
YOU DO THE MAINTENANCE TASK(S).
CAUTION:
MONITOR THE OIL CONSUMPTION OF THE APU VERY CAREFULLY. IF THE OIL CONSUMPTION IS TOO HIGH, OR IF IT INCREASES SUDDENLY, THERE IS A RISK OF DAMAGE TO THE
APU.
4.
Procedure
(Ref. Fig. Oil Servicing SHEET 1) (Ref. Fig. Guideline for the Oil Consumption of the APU 131-9(A) in
Service SHEET 1)
Subtask 49-90-00-612-058-A
A.
Page 5 of 7
Customer : AXM
Manual : AMM
Type : A318/A319/A320/A321
Selected applicability : 228-228
Rev. Date : Feb 01, 2016
49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
NOTE: If the APU page of the ECAM shows 'LOW OIL LEVEL' and there is no oil leakage, Airbus recommends to do oil servicing before 10 APU operating hours.
NOTE: Do the Oil level inspection check and servicing a minimum of 15 minutes after the last shutdown.
Do not re-service before the APU is operated again.
NOTE: If oil consumption is high, do the troubleshooting procedure Ref. TSM 49-00-81-810-867 .
(1) Do a check of the oil level on the sight glass.
NOTE: If the oil level is at the FULL mark on the sight glass, do not add oil to the APU.
(2) Put the CONTAINER 3 L(3/4 USGAL) in position below the APU filling port to collect oil overflow.
(3) Make sure that the filler cap is clean.
WARNING: BE CAREFUL WHEN YOU DRAIN THE ENGINE OIL AND/OR LOOSEN THE FILLER
CAP. HOT OIL CAN SPILL PAST THE FILLER CAP WHEN THE OIL LEVEL IS ABOVE
THE 'ADD' RANGE (MARKED ON THE SIGHT GLASS).
(4) Open the filler cap.
(a) Pull the lock and slowly open the filler cap to release any pressure from the APU.
(5) Add the oil.
WARNING: PUT THE OIL INTO THE GRAVITY-FILL PORT SLOWLY. THIS WILL PREVENT A
BLOW-BACK OF HOT OIL WHICH CAN BURN YOU.
CAUTION: DO NOT FILL THE GEARBOX ABOVE THE FULL MARK ON THE SIGHT GLASS.
DURING APU OPERATION THE OIL EXPANDS WHICH COULD CREATE AN OVERFILLED CONDITION RESULTING IN LEAKAGE AND POSSIBLE OIL SMELL IN THE
CABIN.
(a) Slowly add the oil until the level in the APU is at the FULL mark.
Close-up
Subtask 49-90-00-410-058-A
A.
Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the LIGHT control SW 11LJ to the OFF position.
Page 6 of 7
Customer : AXM
Manual : AMM
Type : A318/A319/A320/A321
Selected applicability : 228-228
Rev. Date : Feb 01, 2016
49-90-00-600-007-A - Check Oil Level and Replenish (131-9(A))
(3) Close the APU access doors 315AL, 316AR (Ref. AMM TASK 52-41-00-410-001) .
(4) Remove the access platform(s).
Subtask 49-90-00-865-063-A
B.
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANEL
121VU
121VU
DESIGNATION
APU/APU/CTL
APU/ECB/SPLY
FIN
2KD
1KD
LOCATION
L42
L41
Subtask 49-90-00-860-061-A
C.
End of document