2 Way Slab Design W/ Drop Panels And No Edge Beam

Name:

Keaten Claney

Job #:

Date:

8/9/2016

Client:

Member Parameters
Slab Thickness
Slab Dead Load
Superimposed Dead Load
Slab Live Load
Drop Panel Thickness
Drop Panel Width
Drop Panel Dead Load
Factored Load at Slab
Factored Load at Drop
Span Length
Column Diameter

t
wd(slab)
wd(superimposed)
LL

wd(drop panel)
wu(slab)
wu(drop)
l
dia.

7 in
87.5 psf
40 psf
100 psf
0 in
4 ft
0 psf
313 psf
313 psf
18 ft
18 in

End Span
Static Moment w/ Slab Loading
Static Moment from Additional Drop
Total Static Moment

Mo

228.18 k-ft
0.00 k-ft
228.18 k-ft

Panel Moments
Exterior Column (-)
Total Bottom Moment
Column Strip (+)
Middle Strip (+)
First Interior Column (-)
Column Strip (-)
Middle Strip (-)

59.33 k-ft
118.65 k-ft
71.19 k-ft
47.46 k-ft
159.72 k-ft
119.79 k-ft
39.93 k-ft
Flexural Reinforcement

*Assuming f'c=4ksi, fy=60ksi


Total Slab Thickness with Drop Panel
Depth at Support
Depth at Slab

h
d1
d2

7 in
5.5 in
5.5 in

Exterior Column:
Column Strip Top Bars Moment
As (d1)
Column Strip Bottom Bars Moment
As (d2)
Middle Strip Bottom Bars Moment
As (d2)

79.10136 k-in/ft
0.278 in^2 / ft
94.921632 k-in/ft
0.337 in^2 / ft
63.281088 k-in/ft
0.221 in^2 / ft
First Interior Column

Column Strip Top Bars Moment


As (d1)
Middle Strip Top Bars Moment
As (d2)

159.7239 k-in/ft
0.586 in^2 / ft
53.2413 k-in/ft
0.186 in^2 / ft

Shear Constants at Exterior Column


b1
b2
b0
Ac
Cab
Ccd
J

20.75 in
23.5 in
65 in
357.5 in^2
6.624 in
14.126 in
17647.67 in^4

Factored Moments and Shears at Centerline of Exterior Column


Span - Column
Vu at ext. Col
Vu at C.L. of ext col
Vext
Mext
M

16.500 ft
46.47 kips
50.70 kips
54.93 kips
95.77 k-ft
72.30 k-ft
Shear Check at Exterior Column

vc1
vc2
.75 Theta Vc
Min yf
yv
vu
theta vc

287.04 psi
252.98 psi
50.87 kips
0.61
0.39
163.53 psi
189.74 psi

Extra Bars in Column Strip at Exterior Column


yf*Mu
Effective Width
Moment per foot width
Min As

36.48 k-ft
3.25 ft
134.69 k-in/ft
0.49 in^2 / ft
Interior Span

Bottom Positive Moment


Column Strip (+)
Middle Strip (+)
Top Negative Moment
Column Strip (-)
Middle Strip (-)

79.86 k-ft
47.92 k-ft
31.94 k-ft
148.32 k-ft
111.24 k-ft
37.08 k-ft

*Greater than Vext?

OK

Interior Moments
Column Strip Bottom Bars Moment
As (d1)
Middle Strip Bottom Bars Moment
As (d1)
Column Strip Top Bars Moment
As (d2)
Middle Strip Top Moment
As(d1)

63.890 k-in/ft
0.224 in^2 /
42.593 k-in/ft
0.148 in^2 /
148.315 k-in/ft
0.540 in^2 /
49.438 k-in/ft
0.172 in^2 /

ft
ft
ft
ft

Shear Constants at Interior Column


b1
b2
b0
Ac
Cab
Ccd
J

23.5 in
23.5 in
94 in
517 in^2
11.750 in
11.750 in
48237.18 in^4

Factored Moments and Shears at Centerline of Interior Column


Span - Column
Vu at int. Col
Vint
Mint
V

16.500 ft
46.47 kips
92.95 kips
27.44 k-ft
31.73 k
Shear Check at Interior Column

vc1
vc2
Factored Shear with No Unbalanced
Theta Vc
Min yf
yv
Factored Shear with Unbalanced
theta vc

274.51 psi
252.98 psi
179.785 psi
189.74 psi
0.60
0.40
93.47 psi
189.74 psi

OK

OK

Shear Check Outside of Drop Panel


b1
b2
b0
Ac
Theta Vc

53.5 in
53.5 in
214 in
1177 in^2
223.32 kips

Reinforcing Bars (E.W.)

As / ft
Total As

Top Ext.
0.278
2.506

Edge Panel
Column Strip
Additional
Bottom
0.49
0.337
1.583
3.029

Top Int.
0.586
5.270

Middle Strip
Bottom
Top Int.
0.221
0.186
1.992
1.670

Interior Panel
Column Strip
Middle Strip
Top
Bottom
Top
Bottom
0.540
0.224
0.172
0.148
4.863
2.012
1.549
1.332

OK