Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Limitorque Actuators
MX-05
Coupling Type
A1
A1E Extended
B4 Rectangular Key
B4 Square Key
B4E (Extended) Rect. Key
B4E (Extended) Square Key
B1 (Fixed Bore)1
BL (Splined)
BL (Splined)
Maximum Turns MX units - 700 Turns for 18/15 & 26/22 RPM
1350 Turns for 40/33 to 200/165 RPM
Maximum Turns MXa units - 10,000
Thrust Rating - 8,000 lbs / 35 kN
3 PHASE / 60 Hz - 460V, 230V, 380V, 575V
3 PHASE / 50 Hz - 380V, 400V, 415V
60Hz RPM
18
26
40
52
77
100
155
200
50Hz RPM
15
22
33
43
65
84
127
165
Ratio
65
65
43
33
22
17
22
17
Start Eff.
0.34
0.38
0.40
0.46
0.55
0.57
0.57
0.62
Stall Factor
0.41
0.46
0.48
0.55
0.64
0.71
0.75
0.76
Motor Start Torque
3.00
2.50
4.00
4.00
4.00
4.00
3.25
3.25
Output Torque
Start (Ft-Lbs)
55
55
55
55
48
39
41
34
Start (Nm)
75
75
75
75
65
53
56
46
MRVS (Ft-Lbs)
67
62
69
61
48
39
41
34
MRVS (Nm)
91
84
94
82
65
53
56
46
Stall (Ft-Lbs)
83
83
83
83
72
59
62
51
Stall (Nm)
113
113
113
113
98
80
84
69
Mod - 100 Starts/Hr (Ft-Lbs)
49
49
49
49
43
NA
NA
NA
Mod - 100 Starts/Hr (Nm)
66
66
66
66
58
NA
NA
NA
Mod - 600 Starts/Hr (Ft-Lbs)
44
44
44
44
38
NA
NA
NA
Mod - 600 Starts/Hr (Nm)
59
59
59
59
51
NA
NA
NA
Mod - 1200 Starts (Ft-Lbs)
38
38
38
38
33
NA
NA
NA
Mod 1200 Starts (Nm)
51
51
51
51
44
NA
NA
NA
1. For 208 Volts multiply above torque values by 0.81
2. "Modulating Continuous" is the maximum modulating running load.
3. 600 Starts/Hr Modulating Service is permissable for limited durations typical of process start-up.
4. Maximum motor stall torque is based on 1.25 X motor start torque.
5. Reduced voltageapplications. Multiply published torque ratings by the derate factors below.
575/460/380/230 volt 60 Hz and 380 volt 50 Hz +10 to -15% = No derate
208 volt 60 Hz and 415/400 50Hz +10 to -15% = 0.81
575/460/380/230 volt 60 Hz and 380 volt 50 Hz +10 to -20% = .81
208 volt 60 Hz and 415/400 50Hz +10 to -20% = 0.81
Mounting Base
OR
Chart - R130-001
Page 1 of 133
WEIGHT - A1 Base
61 Lbs / 28 Kg
Flowserve
Limitorque Actuators
MX-05
Actuator RPM - 60 Hz
Motor RPM
230V (2082) - 60 Hz
1.6
1.4
1.8
1.8
4.2
4.3
6.4
6.4
0.13
0.16
0.26
0.26
0.10
0.12
0.19
0.19
44
54
59
59
0.37
0.46
0.50
0.50
0.78
0.84
0.87
0.87
Power Factor @ Locked Rotor
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
1.2
0.8
1.3
1.3
Locked Rotor Amps (LRA)
2.6
2.1
3.0
3.0
Horsepower (HP)
0.13
0.16
0.26
0.26
Kilowatts (KW)
0.10
0.12
0.19
0.19
Efficiency @ Full Load (%)
37
54
55
55
Power Factor @ Full Load
0.37
0.46
0.52
0.52
0.77
0.84
0.90
0.90
Power Factor @ Locked Rotor
575V - 60 Hz
Full Load Amps (FLA)
0.7
0.8
0.8
0.8
Locked Rotor Amps (LRA)
1.9
2.2
2.9
2.9
Horsepower (HP)
0.13
0.16
0.26
0.26
Kilowatts (KW)
0.10
0.12
0.19
0.19
Efficiency @ Full Load (%)
38
54
54
54
Power Factor @ Full Load
0.39
0.44
0.42
0.42
0.75
0.86
0.87
0.87
Power Factor @ Locked Rotor
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Actuator RPM - 50 Hz
Motor RPM
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
100
1700
155
3400
200
3400
1.8
6.4
0.26
0.19
59
0.50
0.87
1.8
6.4
0.26
0.19
59
0.50
0.87
2.1
10.7
0.42
0.31
60
0.59
0.91
2.1
10.7
0.42
0.31
60
0.59
0.91
1.3
3.0
0.26
0.19
55
0.52
0.90
1.3
3.0
0.26
0.19
55
0.52
0.90
1.3
5.8
0.41
0.31
60
0.59
0.91
1.3
5.8
0.41
0.31
60
0.59
0.91
0.8
2.9
0.26
0.19
54
0.42
0.87
0.8
2.9
0.26
0.19
54
0.42
0.87
1.2
4.4
0.42
0.31
60
0.58
0.91
1.2
4.4
0.42
0.31
60
0.58
0.91
84
1425
127
2800
165
2800
1.4
3.6
0.22
0.16
52
0.40
0.87
1.4
6.2
0.35
0.26
57
0.58
0.95
1.4
6.2
0.35
0.26
57
0.58
0.95
1.3
3.0
0.22
0.16
48
0.38
0.86
1.3
5.8
0.35
0.26
52
0.46
0.91
1.3
5.8
0.35
0.26
52
0.46
0.91
415V (400V3) - 50 Hz
1.2
0.8
1.3
1.3
2.6
2.1
3.0
3.0
0.11
0.14
0.22
0.22
0.087
0.11
0.16
0.16
34
47
48
48
0.37
0.50
0.38
0.38
0.78
0.89
0.86
0.86
Power Factor @ Locked Rotor
3
For 400V service multiply the current values by 1.0375.
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
1.3
3.0
0.22
0.16
48
0.38
0.86
Chart - R130-001
Page 2 of 133
Flowserve
Limitorque Actuators
MX-05
18
1140
26
1700
40
1700
52
1700
230V (2082) - 60 Hz
1.6
1.4
1.8
1.8
4.2
4.3
6.4
6.4
0.13
0.16
0.26
0.26
0.10
0.12
0.19
0.19
44
54
59
59
0.37
0.46
0.50
0.50
0.78
0.84
0.87
0.87
Power Factor @ Locked Rotor
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
1.8
1.2
2.0
2.0
Locked Rotor Amps (LRA)
2.1
3.9
3.0
3.0
Horsepower (HP)
0.13
0.16
0.26
0.26
Kilowatts (KW)
0.10
0.12
0.19
0.19
Efficiency @ Full Load (%)
37
54
55
55
Power Factor @ Full Load
0.37
0.46
0.52
0.52
0.77
0.84
0.90
0.90
Power Factor @ Locked Rotor
575V - 60 Hz
Full Load Amps (FLA)
1.1
1.2
1.2
1.2
Locked Rotor Amps (LRA)
1.9
2.2
2.9
2.9
Horsepower (HP)
0.13
0.16
0.26
0.26
Kilowatts (KW)
0.10
0.12
0.19
0.19
Efficiency @ Full Load (%)
38
54
54
54
Power Factor @ Full Load
0.39
0.44
0.42
0.42
0.75
0.86
0.87
0.87
Power Factor @ Locked Rotor
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
77
1700
100
1700
155
3400
200
3400
1.8
6.4
0.26
0.19
59
0.50
0.87
1.8
6.4
0.26
0.19
59
0.50
0.87
2.1
10.7
0.42
0.31
60
0.59
0.91
2.1
10.7
0.42
0.31
60
0.59
0.91
2.0
3.0
0.26
0.19
55
0.52
0.90
2.0
3.0
0.26
0.19
55
0.52
0.90
2.0
5.8
0.41
0.31
60
0.59
0.91
2.0
5.8
0.41
0.31
60
0.59
0.91
1.2
2.9
0.26
0.19
54
0.42
0.87
1.2
2.9
0.26
0.19
54
0.42
0.87
1.8
4.4
0.42
0.31
60
0.58
0.91
1.8
4.4
0.42
0.31
60
0.58
0.91
15
950
1.7
2.1
0.11
0.08
38
0.44
0.89
22
33
1425
1425
380V - 50 Hz
2.3
2.1
3.9
3.6
0.14
0.22
0.10
0.16
47
52
0.40
0.40
0.91
0.87
43
1425
65
1425
84
1425
127
2800
165
2800
2.1
3.6
0.22
0.16
52
0.40
0.87
2.1
3.6
0.22
0.16
52
0.40
0.87
2.1
3.6
0.22
0.16
52
0.40
0.87
2.1
6.2
0.35
0.26
57
0.58
0.95
2.1
6.2
0.35
0.26
57
0.58
0.95
2.0
3.0
0.22
0.16
48
0.38
0.86
2.0
3.0
0.22
0.16
48
0.38
0.86
2.0
5.8
0.35
0.26
52
0.46
0.91
2.0
5.8
0.35
0.26
52
0.46
0.91
415V (400V3) - 50 Hz
Full Load Amps (FLA)
1.8
1.2
2.0
2.0
Locked Rotor Amps (LRA)
2.6
2.1
3.0
3.0
Horsepower (HP)
0.11
0.14
0.22
0.22
Kilowatts (KW)
0.087
0.11
0.16
0.16
Efficiency @ Full Load (%)
34
47
48
48
Power Factor @ Full Load
0.37
0.50
0.38
0.38
0.78
0.89
0.86
0.86
Power Factor @ Locked Rotor
3
For 400V service multiply the current values by 1.0375.
Full Load is defined as 20% of the rated motor torque.
Chart - R130-001
Page 3 of 133
Flowserve
Limitorque Actuators
MX-10
Coupling Type
A1
A1E Extended
B4 Rectangular Key
B4 Square Key
B4E (Extended) Rect. Key
B4E (Extended) Square Key
B1 (Fixed Bore)1
BL (Splined)
BL (Splined)
Maximum Turns MX units - 700 Turns for 18/15 & 26/22 RPM
1350 Turns for 40/33 to 200/165 RPM
Maximum Turns MXa units - 10,000
Thrust Rating - 15,000 lbs / 67 kN
3 PHASE / 60 Hz -460V, 230V, 380V, 575V
3 PHASE / 50 Hz -380V, 400V, 415V
60Hz RPM
18
26
40
52
77
50Hz RPM
15
22
33
43
65
Ratio
65
65
43
33
22
Start Eff.
0.32
0.33
0.40
0.53
0.54
Stall Factor
0.38
0.45
0.48
0.63
0.72
Motor Start Torque
7.00
5.70
9.00
9.00
9.00
Output Torque
Start (Ft-Lbs)
125
125
125
125
107
Start (Nm)
170
170
170
170
145
MRVS (Ft-Lbs)
144
125
155
156
107
MRVS (Nm)
195
170
210
211
145
Stall (Ft-Lbs)
188
188
188
188
161
Stall (Nm)
255
255
255
255
218
Mod - 100 Starts/Hr (Ft-Lbs)
112
112
112
112
96
Mod - 100 Starts/Hr (Nm)
151
151
151
151
130
Mod - 600 Starts/Hr (Ft-Lbs)
100
100
100
100
85
Mod - 600 Starts/Hr (Nm)
135
135
135
135
115
Mod - 1200 Starts (Ft-Lbs)
87
87
87
87
74
Mod 1200 Starts (Nm)
117
117
117
117
100
100
84
17
.058
0.76
9.00
155
127
22
0.58
0.77
7.00
200
165
17
0.61
0.78
7.00
89
121
89
121
134
182
NA
NA
NA
NA
NA
NA
89
121
89
121
134
182
NA
NA
NA
NA
NA
NA
73
99
73
99
110
149
NA
NA
NA
NA
NA
NA
OR
Chart - R130-002
Page 4 of 133
Flowserve
Limitorque Actuators
MX-10
Actuator RPM - 60 Hz
Motor RPM
230V (2082) - 60 Hz
Full Load Amps (FLA)
4.3
4.0
4.4
4.4
Locked Rotor Amps (LRA)
11.0
11.5
16.2
16.2
Horsepower (HP)
0.31
0.37
0.59
0.59
Kilowatts (KW)
0.23
0.28
0.44
0.44
Efficiency @ Full Load (%)
46
57
63
63
Power Factor @ Full Load
0.42
0.55
0.52
0.52
Power Factor @ Locked Rotor 0.75
0.85
0.81
0.81
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
2.1
1.5
2.5
2.5
Locked Rotor Amps (LRA)
6.3
5.6
8.0
8.0
Horsepower (HP)
0.31
0.37
0.59
0.59
Kilowatts (KW)
0.24
0.28
0.44
0.44
Efficiency @ Full Load (%)
46
57
63
63
Power Factor @ Full Load
0.42
0.55
0.52
0.52
Power Factor @ Locked Rotor 0.75
0.85
0.81
0.81
575V - 60 Hz
Full Load Amps (FLA)
1.5
1.7
1.7
1.7
Locked Rotor Amps (LRA)
4.6
4.9
7.3
7.3
Horsepower (HP)
0.32
0.37
0.59
0.59
Kilowatts (KW)
0.24
0.28
0.44
0.44
Efficiency @ Full Load (%)
46
57
63
63
Power Factor @ Full Load
0.45
0.45
0.50
0.50
Power Factor @ Locked Rotor 0.79
0.83
0.80
0.80
100
1700
155
3400
200
3400
4.4
16.2
0.59
0.44
63
0.52
0.81
4.4
16.2
0.59
0.44
63
0.52
0.81
3.4
22.6
0.91
0.68
80
0.76
0.86
3.4
22.6
0.91
0.68
80
0.76
0.86
2.5
8.0
0.59
0.44
63
0.52
0.81
2.5
8.0
0.59
0.44
63
0.52
0.81
1.4
13.2
0.91
0.68
80
0.76
0.86
1.4
13.2
0.91
0.68
80
0.76
0.86
1.7
7.3
0.59
0.44
63
0.50
0.80
1.7
7.3
0.59
0.44
63
0.50
0.80
1.3
9.6
0.89
0.66
80
0.71
0.86
1.3
9.6
0.89
0.66
80
0.71
0.86
84
1425
127
2800
165
2800
2.3
6.8
0.47
0.35
59
0.46
0.93
1.7
8.5
0.73
0.54
70
0.79
0.89
1.7
8.5
0.73
0.54
70
0.79
0.89
2.5
8.0
0.49
0.37
61
0.44
0.79
1.4
13.2
0.75
0.56
77
0.63
0.70
1.4
13.2
0.75
0.56
77
0.63
0.70
415V (400V3) - 50 Hz
Full Load Amps (FLA)
2.1
1.5
2.5
2.5
Locked Rotor Amps (LRA)
6.3
5.6
8.0
8.0
Horsepower (HP)
0.25
0.31
0.49
0.49
Kilowatts (KW)
0.18
0.23
0.37
0.37
Efficiency @ Full Load (%)
37
53
61
61
Power Factor @ Full Load
0.37
0.49
0.44
0.44
Power Factor @ Locked Rotor 0.64
0.86
0.79
0.79
3
For 400V service multiply the current values above by 1.0375.
2.5
8.0
0.49
0.37
61
0.44
0.79
Chart - R130-002
Page 5 of 133
Flowserve
Limitorque Actuators
MX-10
18
1140
26
1700
40
1700
52
1700
230V (2082) - 60 Hz
Full Load Amps (FLA)
4.3
4.0
4.4
4.4
Locked Rotor Amps (LRA)
11.0
11.5
16.2
16.2
Horsepower (HP)
0.31
0.37
0.59
0.59
Kilowatts (KW)
0.23
0.28
0.44
0.44
Efficiency @ Full Load (%)
46
57
63
63
Power Factor @ Full Load
0.42
0.55
0.52
0.52
Power Factor @ Locked Rotor 0.75
0.85
0.81
0.81
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
3.2
2.3
3.8
3.8
Locked Rotor Amps (LRA)
6.3
5.6
8.0
8.0
Horsepower (HP)
0.31
0.37
0.59
0.59
Kilowatts (KW)
0.24
0.28
0.44
0.44
Efficiency @ Full Load (%)
46
57
63
63
Power Factor @ Full Load
0.42
0.55
0.52
0.52
Power Factor @ Locked Rotor 0.75
0.85
0.81
0.81
575V - 60 Hz
Full Load Amps (FLA)
2.3
2.6
2.6
2.6
Locked Rotor Amps (LRA)
4.6
4.9
7.3
7.3
Horsepower (HP)
0.32
0.37
0.59
0.59
Kilowatts (KW)
0.24
0.28
0.44
0.44
Efficiency @ Full Load (%)
46
57
63
63
Power Factor @ Full Load
0.45
0.45
0.50
0.50
Power Factor @ Locked Rotor 0.79
0.83
0.80
0.80
77
1700
100
1700
155
3400
200
3400
4.4
16.2
0.59
0.44
63
0.52
0.81
4.4
16.2
0.59
0.44
63
0.52
0.81
3.4
22.6
0.91
0.68
80
0.76
0.86
3.4
22.6
0.91
0.68
80
0.76
0.86
3.8
8.0
0.59
0.44
63
0.52
0.81
3.8
8.0
0.59
0.44
63
0.52
0.81
2.9
13.2
0.91
0.68
80
0.76
0.86
2.9
13.2
0.91
0.68
80
0.76
0.86
2.6
7.3
0.59
0.44
63
0.50
0.80
2.6
7.3
0.59
0.44
63
0.50
0.80
2.6
9.6
0.89
0.66
80
0.71
0.86
2.6
9.6
0.89
0.66
80
0.71
0.86
15
950
2.9
4.3
0.24
0.18
50
0.36
0.76
22
33
1425
1425
380V - 50 Hz
2.3
3.5
5.2
6.8
0.31
0.47
0.23
0.35
57
59
0.47
0.46
0.86
0.93
43
1425
65
1425
84
1425
127
2800
165
2800
3.5
6.8
0.47
0.35
59
0.46
0.93
3.5
6.8
0.47
0.35
59
0.46
0.93
3.5
6.8
0.47
0.35
59
0.46
0.93
3.1
8.5
0.73
0.54
70
0.79
0.89
3.1
8.5
0.73
0.54
70
0.79
0.89
415V (400V3) - 50 Hz
Full Load Amps (FLA)
3.2
2.3
3.8
3.8
Locked Rotor Amps (LRA)
6.3
5.6
8.0
8.0
Horsepower (HP)
0.25
0.31
0.49
0.49
Kilowatts (KW)
0.18
0.23
0.37
0.37
Efficiency @ Full Load (%)
37
53
61
61
Power Factor @ Full Load
0.37
0.49
0.44
0.44
Power Factor @ Locked Rotor 0.64
0.86
0.79
0.79
3
For 400V service multiply the current values above by 1.0375.
3.8
8.0
0.49
0.37
61
0.44
0.79
3.8
8.0
0.49
0.37
61
0.44
0.79
2.9
13.2
0.75
0.56
77
0.63
0.70
2.9
13.2
0.75
0.56
77
0.63
0.70
Chart - R130-002
Page 6 of 133
Flowserve
Limitorque Actuators
MX-20
Coupling Type
A1
A1E Extended
B4 Rectangular Key
B4 Square Key
B4E (Extended) Rect. Key
B4E (Extended) Square Key
B1 (Fixed Bore)1
BL (Splined)
BL (Splined)
Maximum Turns MX units - 700 Turns for 18/15 & 26/22 RPM
1350 Turns for 40/33 to 200/165 RPM
Maximum Turns MXa units - 10,000
Thrust Rating - 25,000 lbs / 109 kN
3 PHASE / 60 Hz -460V, 230V, 380V, 575V
3 PHASE / 50 Hz -380V, 400V, 415V
60Hz RPM
18
26
40
52
77
100
155
200
50Hz RPM
15
22
33
43
65
84
127
165
Ratio
65
65
43
33
22
17
22
17
Start Eff.
0.34
0.36
0.42
0.53
0.54
0.58
0.58
0.61
Stall Factor
0.41
0.43
0.50
0.63
0.71
0.73
0.73
0.78
Motor Start Torque
13.00 10.00 15.00 15.00 15.00 15.00 11.00 11.00
Output Torque
Start (Ft-Lbs)
225
225
225
225
178
148
140
114
Start (Nm)
305
305
305
305
241
201
199
155
MRVS (Ft-Lbs)
289
233
269
260
178
148
140
114
MRVS (Nm)
392
316
365
353
241
201
199
155
Stall (Ft-Lbs)
338
338
338
338
267
222
210
171
Stall (Nm)
458
458
458
458
362
302
299
233
Mod - 100 Starts/Hr (Ft-Lbs)
202
202
202
202
160
NA
NA
NA
Mod - 100 Starts/Hr (Nm)
273
273
273
273
216
NA
NA
NA
Mod - 600 Starts/Hr (Ft-Lbs)
180
180
180
180
142
NA
NA
NA
Mod - 600 Starts/Hr (Nm)
244
244
244
244
192
NA
NA
NA
Mod - 1200 Starts (Ft-Lbs)
157
157
157
157
124
NA
NA
NA
Mod 1200 Starts (Nm)
212
212
212
212
168
NA
NA
NA
1. For 208 Volts multiply above torque values by 0.81
2. "Modulating Continuous" is the maximum modulating running load.
3. 600 Starts/Hr Modulating Service is permissable for limited durations typical of process start-up.
4. Maximum motor stall torque is based on 1.25 X motor start torque.
5. Reduced voltageapplications. Multiply published torque ratings by the derate factors below.
575/460/380/230 volt 60 Hz and 380 volt 50 Hz +10 to -15% = No derate
208 volt 60 Hz and 415/400 50Hz +10 to -15% = 0.81
575/460/380/230 volt 60 Hz and 380 volt 50 Hz +10 to -20% = .81
208 volt 60 Hz and 415/400 50Hz +10 to -20% = 0.81
Mounting Base
OR
Chart - R130-003
Page 7 of 133
Flowserve
Limitorque Actuators
MX-20
Actuator RPM - 60 Hz
Motor RPM
230V (2082) - 60 Hz
Full Load Amps (FLA)
6.9
4.3
7.6
7.6
Locked Rotor Amps (LRA)
18.1
19.9
27.5
27.5
Horsepower (HP)
0.57
0.66
0.99
0.99
Kilowatts (KW)
0.43
0.50
0.75
0.75
Efficiency @ Full Load (%)
57
62
67
67
Power Factor @ Full Load
0.52
0.72
0.58
0.58
Power Factor @ Locked Rotor 0.79
0.74
0.79
0.79
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
2.2
1.7
3.5
3.5
Locked Rotor Amps (LRA)
9.5
10.0
15.5
15.5
Horsepower (HP)
0.57
0.66
0.99
0.99
Kilowatts (KW)
0.43
0.50
0.75
0.75
Efficiency @ Full Load (%)
57
62
68
68
Power Factor @ Full Load
0.52
0.72
0.55
0.55
Power Factor @ Locked Rotor 0.79
0.74
0.79
0.79
575V - 60 Hz
Full Load Amps (FLA)
2.0
1.5
2.3
2.3
Locked Rotor Amps (LRA)
7.5
8.3
12.4
12.4
Horsepower (HP)
0.57
0.66
0.99
0.99
Kilowatts (KW)
0.43
0.50
0.75
0.75
Efficiency @ Full Load (%)
57
62
67
67
Power Factor @ Full Load
0.52
0.72
0.58
0.58
Power Factor @ Locked Rotor 0.79
0.74
0.79
0.79
100
1700
155
3400
200
3400
7.6
27.5
0.99
0.75
67
0.58
0.79
7.6
27.5
1.99
0.75
67
0.58
0.79
5.7
34.0
1.42
1.04
81
0.74
0.84
5.7
34.0
1.42
1.04
81
0.74
0.84
3.5
15.5
0.99
0.75
68
0.55
0.79
3.5
15.5
0.99
0.75
68
0.55
0.79
3.5
17.8
1.42
1.04
81
0.76
0.84
3.5
17.8
1.42
1.04
81
0.76
0.84
2.3
12.4
0.99
0.75
67
0.58
0.79
2.3
12.4
0.99
0.75
67
0.58
0.79
2.4
15.7
1.42
1.04
81
0.74
0.84
2.4
15.7
1.42
1.04
81
0.74
0.84
84
1425
127
2800
165
2800
3.3
12.1
0.80
0.59
58
0.51
0.84
3.5
13.6
1.16
0.87
70
0.62
0.87
3.5
13.6
1.16
0.87
70
0.62
0.87
3.5
15.5
0.81
0.60
62
0.56
0.74
3.5
17.8
1.17
0.87
73
0.60
0.82
3.5
17.8
1.17
0.87
73
0.60
0.82
415V (400V3) - 50 Hz
Full Load Amps (FLA)
2.2
1.7
3.5
3.5
Locked Rotor Amps (LRA)
9.5
10.0
15.5
15.5
Horsepower (HP)
0.46
0.54
0.81
0.81
Kilowatts (KW)
0.34
0.40
0.60
0.60
Efficiency @ Full Load (%)
48
59
62
62
Power Factor @ Full Load
0.48
0.56
0.56
0.56
Power Factor @ Locked Rotor 0.82
0.71
0.74
0.74
3
For 400V service multiply the current values above by 1.0375.
Full Load is defined as 20% of the rated motor torque.
* Current values for Arctic units will be higher. See next page.
Chart - R130-003
Page 8 of 133
3.5
15.5
0.81
0.60
62
0.56
0.74
Flowserve
Limitorque Actuators
MX-20
18
1140
26
1700
40
1700
52
1700
230V (2082) - 60 Hz
Full Load Amps (FLA)
6.9
4.3
7.6
7.6
Locked Rotor Amps (LRA)
18.1
19.9
27.5
27.5
Horsepower (HP)
0.57
0.66
0.99
0.99
Kilowatts (KW)
0.43
0.50
0.75
0.75
Efficiency @ Full Load (%)
57
62
67
67
Power Factor @ Full Load
0.52
0.72
0.58
0.58
Power Factor @ Locked Rotor 0.79
0.74
0.79
0.79
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
3.3
2.6
5.5
5.5
Locked Rotor Amps (LRA)
9.5
10.0
15.5
15.5
Horsepower (HP)
0.57
0.66
0.99
0.99
Kilowatts (KW)
0.43
0.50
0.75
0.75
Efficiency @ Full Load (%)
57
62
68
68
Power Factor @ Full Load
0.52
0.72
0.55
0.55
Power Factor @ Locked Rotor 0.79
0.74
0.79
0.79
575V - 60 Hz
Full Load Amps (FLA)
3.0
2.3
3.5
3.5
Locked Rotor Amps (LRA)
7.5
8.3
12.4
12.4
Horsepower (HP)
0.57
0.66
0.99
0.99
Kilowatts (KW)
0.43
0.50
0.75
0.75
Efficiency @ Full Load (%)
57
62
67
67
Power Factor @ Full Load
0.52
0.72
0.58
0.58
Power Factor @ Locked Rotor 0.79
0.74
0.79
0.79
77
1700
100
1700
155
3400
200
3400
7.6
27.5
0.99
0.75
67
0.58
0.79
7.6
27.5
1.99
0.75
67
0.58
0.79
5.7
34.0
1.42
1.04
81
0.74
0.84
5.7
34.0
1.42
1.04
81
0.74
0.84
5.5
15.5
0.99
0.75
68
0.55
0.79
5.5
15.5
0.99
0.75
68
0.55
0.79
5.5
17.8
1.42
1.04
81
0.76
0.84
5.5
17.8
1.42
1.04
81
0.76
0.84
3.5
12.4
0.99
0.75
67
0.58
0.79
3.5
12.4
0.99
0.75
67
0.58
0.79
4.0
15.7
1.42
1.04
81
0.74
0.84
4.0
15.7
1.42
1.04
81
0.74
0.84
15
950
5.0
8.7
0.48
0.36
45
0.41
0.85
22
33
1425
1425
380V - 50 Hz
3.3
5.0
10.2
12.1
0.55
0.80
0.41
0.59
63
58
0.52
0.51
0.85
0.84
43
1425
65
1425
84
1425
127
2800
165
2800
5.0
12.1
0.80
0.59
58
0.51
0.84
5.0
12.1
0.80
0.59
58
0.51
0.84
5.0
12.1
0.80
0.59
58
0.51
0.84
5.3
13.6
1.16
0.87
70
0.62
0.87
5.3
13.6
1.16
0.87
70
0.62
0.87
415V (400V3) - 50 Hz
Full Load Amps (FLA)
3.3
2.6
5.5
5.5
Locked Rotor Amps (LRA)
9.5
10.0
15.5
15.5
Horsepower (HP)
0.46
0.54
0.81
0.81
Kilowatts (KW)
0.34
0.40
0.60
0.60
Efficiency @ Full Load (%)
48
59
62
62
Power Factor @ Full Load
0.48
0.56
0.56
0.56
Power Factor @ Locked Rotor 0.82
0.71
0.74
0.74
3
For 400V service multiply the current values above by 1.0375.
5.5
15.5
0.81
0.60
62
0.56
0.74
5.5
15.5
0.81
0.60
62
0.56
0.74
5.5
17.8
1.17
0.87
73
0.60
0.82
5.5
17.8
1.17
0.87
73
0.60
0.82
Chart - R130-003
Page 9 of 133
Flowserve
Limitorque Actuators
MX-40
Coupling Type
A1
A1E Extended
B4 Rectangular Key
B4 Square Key
B4E (Extended) Rect. Key
B4E (Extended) Square Key
B1 (Fixed Bore)1
BL (Splined)
Maximum Turns MX units - 700 Turns for 18/15 & 26/22 RPM
1350 Turns for 40/33 to 200/165 RPM
Maximum Turns MXa units - 10,000
Thrust Rating - 36,000 lbs / 158 kN
3 PHASE / 60 Hz -460V, 230V, 380V, 575V
3 PHASE / 50 Hz -380V, 400V, 415V
60Hz RPM
18
26
40
52
77
100
155
200
50Hz RPM
15
22
33
43
65
84
127
165
Ratio
65
65
43
33
22
17
22
17
Start Eff.
0.30
0.36
0.40
0.48
0.54
0.58
0.51
0.54
Stall Factor
0.36
0.43
0.48
0.58
0.63
0.68
0.68
0.68
Motor Start Torque
25.00 20.00 29.00 29.00 29.00 29.00 23.00 23.00
Output Torque
Start (Ft-Lbs)
440
440
440
440
345
286
260
210
Start (Nm)
597
597
597
597
468
388
353
285
MRVS (Ft-Lbs)
488
466
499
463
345
286
260
210
MRVS (Nm)
662
632
677
628
468
388
353
285
Stall (Ft-Lbs)
660
660
660
660
518
429
390
315
Stall (Nm)
896
896
896
896
702
582
530
428
Mod - 100 Starts/Hr (Ft-Lbs)
396
396
396
396
310
NA
NA
NA
Mod - 100 Starts/Hr (Nm)
536
536
536
536
420
NA
NA
NA
Mod - 600 Starts/Hr (Ft-Lbs)
352
352
352
352
276
NA
NA
NA
Mod - 600 Starts/Hr (Nm)
477
477
477
477
374
NA
NA
NA
Mod - 1200 Starts (Ft-Lbs)
308
308
308
308
241
NA
NA
NA
Mod 1200 Starts (Nm)
417
417
417
417
326
NA
NA
NA
1. For 208 Volts multiply above torque values by 0.81
2. "Modulating Continuous" is the maximum modulating running load.
3. 600 Starts/Hr Modulating Service is permissable for limited durations typical of process start-up.
4. Maximum motor stall torque is based on 1.25 X motor start torque.
5. Reduced voltageapplications. Multiply published torque ratings by the derate factors below.
575/460/380/230 volt 60 Hz and 380 volt 50 Hz +10 to -15% = No derate
208 volt 60 Hz and 415/400 50Hz +10 to -15% = 0.81
575/460/380/230 volt 60 Hz and 380 volt 50 Hz +10 to -20% = .81
208 volt 60 Hz and 415/400 50Hz +10 to -20% = 0.81
Mounting Base
OR
Chart - R130-004
Page 10 of 133
Flowserve
Limitorque Actuators
MX-40
Actuator RPM - 60 Hz
Motor RPM
230V (2082) - 60 Hz
Full Load Amps (FLA)
10.8
7.4
15.0
15.0
Locked Rotor Amps (LRA)
37.0
39.0
59.5
59.5
Horsepower (HP)
1.10
1.30
1.90
1.90
Kilowatts (KW)
0.82
0.97
1.42
1.42
Efficiency @ Full Load (%)
63
70
71
71
Power Factor @ Full Load
0.40
0.65
0.63
0.63
Power Factor @ Locked Rotor 0.91
0.81
0.87
0.87
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
4.8
3.6
5.0
5.0
Locked Rotor Amps (LRA)
19.5
24.3
26.0
26.0
Horsepower (HP)
1.10
1.30
1.90
1.90
Kilowatts (KW)
0.82
0.97
1.42
1.42
Efficiency @ Full Load (%)
62
70
71
71
Power Factor @ Full Load
0.39
0.65
0.63
0.63
Power Factor @ Locked Rotor 0.91
0.81
0.87
0.87
575V - 60 Hz
Full Load Amps (FLA)
3.2
2.7
4.1
4.1
Locked Rotor Amps (LRA)
14.3
14.3
19.1
19.1
Horsepower (HP)
1.10
1.30
1.90
1.90
Kilowatts (KW)
0.82
0.97
1.42
1.42
Efficiency @ Full Load (%)
63
70
71
71
Power Factor @ Full Load
0.39
0.65
0.63
0.63
Power Factor @ Locked Rotor 0.91
0.81
0.87
0.87
100
1700
155
3400
200
3400
15.0
59.5
1.90
1.42
71
0.63
0.87
15.0
59.5
1.90
1.42
71
0.63
0.87
11.1
75.0
3.00
2.24
80
0.78
0.78
11.1
75.0
3.00
2.24
80
0.78
0.78
5.0
26.0
1.90
1.42
71
0.63
0.87
5.0
26.0
1.90
1.42
71
0.63
0.87
4.7
30.0
3.00
2.24
81
0.78
0.78
4.7
30.0
3.00
2.24
81
0.78
0.78
4.1
19.1
1.90
1.42
71
0.63
0.87
4.1
19.1
1.90
1.42
71
0.63
0.87
4.0
30.0
3.00
2.24
81
0.78
0.78
4.0
30.0
3.00
2.24
81
0.78
0.78
84
1425
127
2800
165
2800
6.0
20.0
1.57
1.18
64
0.49
0.79
7.1
44.0
2.38
1.77
76
0.71
0.85
7.1
44.0
2.38
1.77
76
0.71
0.85
5.0
26.0
1.57
1.17
62
0.63
0.80
4.7
30.0
2.44
1.82
73
0.69
0.79
4.7
30.0
2.44
1.82
73
0.69
0.79
415V (400V3) - 50 Hz
Full Load Amps (FLA)
4.8
3.6
5.0
5.0
Locked Rotor Amps (LRA)
19.5
24.3
26.0
26.0
Horsepower (HP)
0.89
1.10
1.57
1.57
Kilowatts (KW)
0.66
0.82
1.17
1.17
Efficiency @ Full Load (%)
53
63
62
62
Power Factor @ Full Load
0.39
0.52
0.63
0.63
Power Factor @ Locked Rotor 0.66
0.73
0.80
0.80
3
For 400V service multiply the current values above by 1.0375.
5.0
26.0
1.57
1.17
62
0.63
0.80
Chart - R130-004
Page 11 of 133
Flowserve
Limitorque Actuators
MX-40
18
1140
26
1700
40
1700
52
1700
230V (2082) - 60 Hz
Full Load Amps (FLA)
10.8
7.4
15.0
15.0
Locked Rotor Amps (LRA)
37.0
39.0
59.5
59.5
Horsepower (HP)
1.10
1.30
1.90
1.90
Kilowatts (KW)
0.82
0.97
1.42
1.42
Efficiency @ Full Load (%)
63
70
71
71
Power Factor @ Full Load
0.40
0.65
0.63
0.63
Power Factor @ Locked Rotor 0.91
0.81
0.87
0.87
2
For 208V multiply the current values above by 1.1
460V - 60 Hz
Full Load Amps (FLA)
7.2
5.4
7.5
7.5
Locked Rotor Amps (LRA)
19.5
24.3
26.0
26.0
Horsepower (HP)
1.10
1.30
1.90
1.90
Kilowatts (KW)
0.82
0.97
1.42
1.42
Efficiency @ Full Load (%)
62
70
71
71
Power Factor @ Full Load
0.39
0.65
0.63
0.63
Power Factor @ Locked Rotor 0.91
0.81
0.87
0.87
575V - 60 Hz
Full Load Amps (FLA)
4.8
4.2
6.5
6.5
Locked Rotor Amps (LRA)
14.3
14.3
19.1
19.1
Horsepower (HP)
1.10
1.30
1.90
1.90
Kilowatts (KW)
0.82
0.97
1.42
1.42
Efficiency @ Full Load (%)
63
70
71
71
Power Factor @ Full Load
0.39
0.65
0.63
0.63
Power Factor @ Locked Rotor 0.91
0.81
0.87
0.87
77
1700
100
1700
155
3400
200
3400
15.0
59.5
1.90
1.42
71
0.63
0.87
15.0
59.5
1.90
1.42
71
0.63
0.87
11.1
75.0
3.00
2.24
80
0.78
0.78
11.1
75.0
3.00
2.24
80
0.78
0.78
7.5
26.0
1.90
1.42
71
0.63
0.87
7.5
26.0
1.90
1.42
71
0.63
0.87
8.7
30.0
3.00
2.24
81
0.78
0.78
8.7
30.0
3.00
2.24
81
0.78
0.78
6.5
19.1
1.90
1.42
71
0.63
0.87
6.5
19.1
1.90
1.42
71
0.63
0.87
7.5
30.0
3.00
2.24
81
0.78
0.78
7.5
30.0
3.00
2.24
81
0.78
0.78
15
950
8.3
18.0
0.90
0.67
52
0.41
0.79
22
33
1425
1425
380V - 50 Hz
5.9
9.0
18.9
20.0
1.09
1.57
0.81
1.18
71
64
0.52
0.49
0.83
0.79
43
1425
65
1425
84
1425
127
2800
165
2800
9.0
20.0
1.57
1.18
64
0.49
0.79
9.0
20.0
1.57
1.18
64
0.49
0.79
9.0
20.0
1.57
1.18
64
0.49
0.79
11.5
44.0
2.38
1.77
76
0.71
0.85
11.5
44.0
2.38
1.77
76
0.71
0.85
415V (400V3) - 50 Hz
Full Load Amps (FLA)
7.2
5.4
7.5
7.5
Locked Rotor Amps (LRA)
19.5
24.3
26.0
26.0
Horsepower (HP)
0.89
1.10
1.57
1.57
Kilowatts (KW)
0.66
0.82
1.17
1.17
Efficiency @ Full Load (%)
53
63
62
62
Power Factor @ Full Load
0.39
0.52
0.63
0.63
Power Factor @ Locked Rotor 0.66
0.73
0.80
0.80
3
For 400V service multiply the current values above by 1.0375.
7.5
26.0
1.57
1.17
62
0.63
0.80
7.5
26.0
1.57
1.17
62
0.63
0.80
8.7
30.0
2.44
1.82
73
0.69
0.79
8.7
30.0
2.44
1.82
73
0.69
0.79
Chart - R130-004
Page 12 of 133
Flowserve
Limitorque Actuators
MX-85
Maximum Stem Capacity
Coupling Type
Application
Inches
A1
Thrust & Torque
3.50
A1E Extended
Thrust & Torque
3.50
B4 (Bore & Max Key)
Torque Only
2.75, 5/8x7/16 Key
B4E (Extended) (Bore & Max Key)
Torque Only
2.25, 1/2x3/8 Key
mm
88.0
88.0
70, 20x12
56, 16x10
26
22
65
0.34
0.41
45
40
33
43
0.51
0.66
62
52
43
33
0.65
0.84
62
77
65
22
0.72
0.93
62
131
110
13
0.78
1.12
62
170
143
10
0.84
1.09
62
600
814
720
976
900
1221
NA
NA
NA
NA
450
610
540
732
675
916
NA
NA
NA
NA
540
732
648
878
810
1098
NA
NA
NA
NA
405
549
486
659
607
824
NA
NA
NA
NA
OR
OR
Chart - R130-005
Page 13 of 133
Flowserve
Limitorque Actuators
MX-85
Actuator RPM - 60 Hz
Motor RPM
460V - 60 Hz
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
575V - 60 Hz
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
10.3
46.0
4.0
3.0
0.75
0.63
0.86
10.3
46.0
4.0
3.0
0.75
0.63
0.86
10.3
46.0
4.0
3.0
0.75
0.63
0.86
10.3
46.0
4.0
3.0
0.75
0.63
0.86
10.3
46.0
4.0
3.0
0.75
0.63
0.86
4.1
22.0
2.9
2.9
0.76
0.70
0.76
8.5
37.0
4.0
4.0
0.75
0.63
0.86
8.5
37.0
4.0
4.0
0.75
0.63
0.86
8.5
37.0
4.0
4.0
0.75
0.63
0.86
8.5
37.0
4.0
4.0
0.75
0.63
0.86
8.5
37.0
4.0
4.0
0.75
0.63
0.86
65
1425
110
1425
143
1425
9.2
34.0
3.3
2.5
0.77
0.67
0.94
9.2
34.0
3.3
2.5
0.77
0.67
0.94
9.2
34.0
3.3
2.5
0.77
0.67
0.94
11.5
36.0
3.40
2.50
0.71
0.55
0.91
11.5
36.0
3.40
2.50
0.71
0.55
0.91
11.5
36.0
3.40
2.50
0.71
0.55
0.91
13.1
36.0
3.40
2.50
0.71
0.55
0.91
13.1
36.0
3.40
2.50
0.71
0.55
0.91
13.1
36.0
3.40
2.50
0.71
0.55
0.91
Chart - R130-005
170
1700
Page 14 of 133
Flowserve
Limitorque Actuators
MX-85
26
1700
40
1700
52
1700
77
1700
131
1700
170
1700
9.0
28.0
2.9
2.9
0.76
0.7
0.76
11.0
46.0
4.0
3.0
0.75
0.63
0.86
11.0
46.0
4.0
3.0
0.75
0.63
0.86
11.0
46.0
4.0
3.0
0.75
0.63
0.86
11.0
46.0
4.0
3.0
0.75
0.63
0.86
11.0
46.0
4.0
3.0
0.75
0.63
0.86
7.5
28.0
2.9
2.2
0.76
0.70
0.76
11.1
46.0
4.0
3.0
0.75
0.63
0.86
11.1
46.0
4.0
3.0
0.75
0.63
0.86
11.1
46.0
4.0
3.0
0.75
0.63
0.86
11.1
46.0
4.0
3.0
0.75
0.63
0.86
11.1
46.0
4.0
3.0
0.75
0.63
0.86
110
1425
143
1425
11.0
46.0
3.3
2.5
0.77
0.67
0.94
11.0
46.0
3.3
2.5
0.77
0.67
0.94
11.0
46.0
3.40
2.50
0.71
0.55
0.91
11.0
46.0
3.40
2.50
0.71
0.55
0.91
11.0
46.0
3.40
2.50
0.71
0.55
0.91
11.0
46.0
3.40
2.50
0.71
0.55
0.91
Chart - R130-005
Page 15 of 133
Flowserve
Limitorque Actuators
MX-140
Coupling Type
A1
A1E Extended
B4 (Bore & Max Key)
B4E (Extended) (Bore & Max Key)
mm
88.0
88.0
65, 18x11
56, 16x10
26
22
65
0.34
0.41
62
40
33
43
0.51
0.66
85
52
43
33
0.65
0.84
85
77
65
22
0.72
0.93
85
131
110
13
0.78
1.12
85
170
143
10
0.84
1.09
85
815
1105
978
1326
1223
1659
NA
NA
NA
NA
650
881
780
1057
975
1323
NA
NA
NA
NA
733
994
880
1193
1100
1493
NA
NA
NA
NA
585
792
702
951
877
1190
NA
NA
NA
NA
HW Ratio
16
Chart - R130-006
OR
Page 16 of 133
Flowserve
Actuator RPM - 60 Hz
Motor RPM
460V - 60 Hz*
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
575V - 60 Hz*
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
170
1700
9.5
46.0
4.0
3.0
0.75
0.63
0.86
14.7
60.0
5.4
4.1
0.67
0.68
0.84
14.7
60.0
5.4
4.1
0.67
0.68
0.84
14.7
60.0
5.4
4.1
0.67
0.68
0.84
14.7
60.0
5.4
4.1
0.67
0.68
0.84
14.7
60.0
5.4
4.1
0.67
0.68
0.84
6.2
37.0
4.00
3.00
0.75
0.63
0.86
12.4
48.0
5.40
6.00
0.67
0.68
0.84
12.4
48.0
5.40
6.00
0.67
0.68
0.84
12.4
48.0
5.40
6.00
0.67
0.68
0.84
12.4
48.0
5.40
6.00
0.67
0.68
0.84
12.4
48.0
5.40
6.00
0.67
0.68
0.84
65
1425
110
1425
143
1425
13.7
55.0
4.6
1.8
0.78
0.65
0.83
13.7
55.0
4.6
1.8
0.78
0.65
0.83
13.7
55.0
4.6
1.8
0.78
0.65
0.83
16.5
60.0
4.60
3.40
0.67
0.60
0.86
16.5
60.0
4.60
3.40
0.67
0.60
0.86
16.5
60.0
4.60
3.40
0.67
0.60
0.86
19.3
68.0
4.60
3.40
0.67
0.60
0.86
19.3
68.0
4.60
3.40
0.67
0.60
0.86
19.3
68.0
4.60
3.40
0.67
0.60
0.86
Chart - R130-006
Limitorque Actuators
MX-140
Page 17 of 133
Flowserve
Limitorque Actuators
MX-140
26
1700
40
1700
52
1700
77
1700
131
1700
170
1700
11.0
46.0
4.0
3.0
0.75
0.63
0.86
17.2
68.0
5.4
4.1
0.67
0.68
0.84
17.2
68.0
5.4
4.1
0.67
0.68
0.84
17.2
68.0
5.4
4.1
0.67
0.68
0.84
17.2
68.0
5.4
4.1
0.67
0.68
0.84
17.2
68.0
5.4
4.1
0.67
0.68
0.84
11.1
46.0
4.00
3.00
0.75
0.63
0.86
17.2
68.0
5.40
6.00
0.67
0.68
0.84
17.2
68.0
5.40
6.00
0.67
0.68
0.84
17.2
68.0
5.40
6.00
0.67
0.68
0.84
17.2
68.0
5.40
6.00
0.67
0.68
0.84
17.2
68.0
5.40
6.00
0.67
0.68
0.84
110
1425
143
1425
18.3
68.0
2.4
1.8
0.78
0.65
0.83
18.3
68.0
2.4
1.8
0.78
0.65
0.83
17.2
68.0
4.60
3.40
0.67
0.60
0.86
17.2
68.0
4.60
3.40
0.67
0.60
0.86
17.2
68.0
4.60
3.40
0.67
0.60
0.86
17.2
68.0
4.60
3.40
0.67
0.60
0.86
Chart - R130-006
Page 18 of 133
Flowserve
Limitorque Actuators
MX-150
Maximum Stem Capacity
Application
Thrust & Torque
Thrust & Torque
Coupling Type
A1
A1E Extended
B4 (Bore & Max Key)
B4E (Extended) (Bore & Max Key)
Torque Only
Torque Only
Inches
3.50
3.50
mm
88.0
88.0
65, 18x11
56, 16x10
131
110
13
0.78
1.12
150
170
143
10
0.84
1.09
150
380V
1350
1830
1620
2195
1890
2560
1035
1400
1240
1681
1450
1965
OR
Chart - R130-007
Page 19 of 133
Flowserve
MX-150
Limitorque Actuators
170
3400
16.5
116.0
10.0
7.5
0.67
0.68
0.84
16.5
116.0
10.0
7.5
0.67
0.68
0.84
143
2800
380V - 50 Hz
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
16.2
130.0
8.4
6.3
0.78
0.65
0.83
16.2
130.0
8.4
6.3
0.78
0.65
0.83
400V - 50 Hz
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
15.0
120.0
8.4
6.3
0.67
0.60
0.86
15.0
120.0
8.4
6.3
0.67
0.60
0.86
415V - 50 Hz
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
16.0
120.0
8.4
6.3
0.67
0.60
0.86
16.0
120.0
8.4
6.3
0.67
0.60
0.86
Chart - R130-007
Page 20 of 133
Flowserve
Limitorque Actuators
MX-HS
MX-10/HS
MX-20/HS
MX-40/HS
MX-85/HS
(in)
2.00 diam
1/2 sq key
2.00 diam
1/2 sq key
2.875 diam
3/4 sq key
2.875 diam
3/4 sq key
(mm)
51 diam
16 x 10 key
51 diam
16 x 10 key
73 diam
20 x 12 key
73 diam
20 x 12 key
(in)
2.00 diam
1/2 x 3/8 key
2.00 diam
1/2 x 3/8 key
2.875 diam
3/4 x 1/2 key
2.875 diam
3/4 x 1/2 key
START TORQUEnote 1
MRVS TORQUEnote 1
STALL TORQUEnote 1
MX-10/HS
MX-20/HS
MX-40/HS
MX-85/HS
139
202
101
149
197
129
140
198
104
152
195
168
245
123
181
239
129
170
240
126
184
237
(Ft-Lbs)
36
28
19
69
47
36
130
98
70
369
253
197
(Nm)
49
38
26
94
64
49
177
134
96
503
345
269
(Ft-Lbs)
41
32
22
82
56
43
147
111
79
443
304
236
(Nm)
56
44
30
112
77
59
201
152
109
604
414
323
(Ft-Lbs)
54
42
29
104
71
54
195
147
105
554
380
296
(Nm)
74
57
39
141
96
74
266
201
144
755
518
404
Power supplies - MX-10/HS, MX-20/HS, MX-40/HS --- 3 PHASE / 60 Hz -460V, 230V, 380V, 575V and
3 PHASE / 50 Hz -380V, 400V, 415V, 440V
Power supplies - MX-85/HS --- 3 PHASE / 60 Hz -460V, 575V and 3 PHASE / 50 Hz -400V, 415V (MX-85/HS can also
be supplied as 50 hz, 380V, derate torque values by 10%)
MX-10/HS
HS gearbox ratio (HS is an
increaser gear)
3.3
4.2
MX-20/HS
6.1
3.1
4.5
6.0
HS gearbox efficiency
Maximum turns
3.2
MX-85/HS
4.3
6.0
3.1
4.6
5.9
4.1
5.7
2.9
4.4
5.6
95%
Handwheel torque
multipliernote 2
Weight (HS only)note 3
MX-40/HS
3.1
5.8
2.9
4.3
5.7
(Lbs)
50
71
238
403
(Kg)
22
32
106
180
409
321
221
435
300
Motor ratings
225
422
314
225
429
289
225
(see note 1)
Note 1 - All selections are based on MX units that are speed 3 (40 RPM @ 60hz, 33 RPM @ 50hz) type. Refer to
specific MX chart for MX ratios, motor ratings, etc
Note 2 - Multiply the required valve torque by this factor and use this value to calculate the rim pull
Note 3 - Weight is for the HS gearbox only, add to MX weight
Chart - R130-008
Page 21 of 133
Flowserve
Limitorque Actuators
SMB-000
60Hz RPM
50Hz RPM
4P Motors
2P Motors
60Hz RPM
50Hz RPM
2/4P
2/2P
5/4P
5/2P1
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
17
14
72
72
155
23
19
54
54
116
120
135
225
MRVS
Stall
1For use on Postion Seat Applications ONLY.
30
25
41
41
89
102
102
171
86
195
86
71
23
23
53
26
26
54
57
57
102
65
99
81
19
19
44
24
24
50
48
48
86
60
123
101
14
14
34
30
30
60
36
36
65
75
65
149
60
136
75
166
137
112
13
13
31
159
131
190
157
23
23
46
19
19
39
57
48
57
126
48
106
33
33
60
WEIGHTS (Lbs)
Controls
Top HW
NCU
135
All Nuclear Safety Related Applications are to be referred to our Lynchburg Headquarters
Chart - R100-001
Page 22 of 133
Flowserve
SMB-000
Limitorque Actuators
MOTOR RATINGS
Motor Size (Ft. Lb.)
2/4P
0.6
3.5
0.13
0.10
1
0.60
0.76
2/4P
1.2
7
0.13
1.1
0.56
0.60
0.76
2/4P
0.48
2.5
0.125
0.10
0.56
0.60
0.76
Motor Size
2/DC
1.6
16
0.144
0.11
0.43
2/2P
5/4P
460V - 60 Hz
0.55
1.0
5.0
5.5
0.25
0.33
0.19
0.25
0.74
0.57
0.76
5/2P
2/2P
5/4P
230V - 60 Hz
1.1
2.0
10
11
0.25
0.33
0.19
0.25
0.74
0.57
0.76
5/2P
1.31
10.4
0.65
0.48
0.71
0.73
0.80
2.62
20.8
0.65
0.49
0.71
0.73
0.80
2/2P
5/4P
5/2P
575V - 60 Hz
0.8
4.5
0.33
0.25
0.74
0.57
0.76
5/DC
125V DC
3.8
22.0
0.361
0.27
0.68
Motor Size
2/DC
0.8
5
0.144
0.11
0.52
5/DC
250V DC
1.9
10.4
0.361
0.27
0.74
Chart - R100-001
Page 23 of 133
Flowserve
Limitorque Actuators
4P Motors
2P Motors
24
19
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
60Hz RPM
50Hz RPM
25/40
72.00
0.36
0.50
3 PHASE MOTORS
44
50
60
74
36
41
50
61
45 : 1 (Self Locking)
35/30 37/28 40/25 43/22
38.57 34.05 28.13 23.02
0.36
0.36
0.36
0.36
0.60
0.60
0.60
0.60
88
73
121
100
148
122
45 : 1 (Self Locking)
35/30 37/28 40/25 43/22
38.57 34.05 28.13 23.02
0.41
0.41
0.41
0.41
0.65
0.65
0.65
0.65
24
19
259
259
421
88
73
Start
MRVS
Stall
Start
158
10/2P
MRVS
158
Stall
311
Start
208
183
151
124
15/4P
MRVS
208
183
151
124
Stall
405
358
295
242
Start
237
1
15/2P
MRVS
237
Stall
501
Start
253
207
25/4P
MRVS
253
207
Stall
500
409
1For SMB's use on Postion Seat Applications ONLY, for SB's Torque Seating is permitted.
For SBs use a 0.9 Application Factor on the Output Torque.
10/4P
100
82
100
82
121
100
148
122
139
139
274
115
115
227
94
94
186
209
209
443
172
172
366
141
141
299
WEIGHTS (Lbs)
Controls
Side HW
SMB NCU
225
SB NCU
290
All Nuclear Safety Related Applications are to be referred to our Lynchburg Headquarters
Chart - R100-002
Page 24 of 133
Flowserve
Limitorque Actuators
MOTOR RATINGS
Motor Size (Ft. Lb.)
10/4P
2.3
12
0.67
0.50
0.67
0.48
0.82
10/4P
4.6
24
0.67
0.5
0.67
0.48
0.82
10/4P
1.9
10.0
0.67
0.50
0.67
0.48
0.82
Motor Size
10/DC
Chart - R100-002
10/DC
3.4
19.5
0.722
0.54
0.73
10/2P 15/4P
460V - 60 Hz
2.4
2.8
16
16
1.3
1.0
0.97
0.75
0.75
0.70
0.70
0.45
0.84
0.80
15/2P
25/4P
3.5
26
2.0
1.49
0.83
0.68
0.79
4.0
25.5
1.6
1.19
0.73
0.57
0.80
10/2P 15/4P
230V - 60 Hz
4.8
5.6
32
32
1.3
1.0
0.97
0.75
0.75
0.70
0.70
0.45
0.84
0.80
15/2P
25/4P
7.0
52
2.0
1.49
0.83
0.68
0.79
8.0
51
1.6
1.19
0.73
0.57
0.80
10/2P 15/4P
575V - 60 Hz
1.9
2.2
13.0
12.8
1.33
1.0
0.97
0.75
0.75
0.70
0.70
0.45
0.84
0.80
15/2P
25/4P
2.8
21.0
2.0
1.49
0.83
0.68
0.79
3.2
20.0
1.6
1.19
0.73
0.57
0.80
15/DC
125V DC
9.4
50
1.083
0.81
0.69
25/DC
15/DC
250V DC
4.7
25
1.083
0.81
0.69
25/DC
14.5
82
1.805
1.35
0.75
7.5
42
1.805
1.35
0.71
Page 25 of 133
Flowserve
Limitorque Actuators
4P Motors
2P Motors
18
15
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
20/52
96.20
0.36
0.50
3 PHASE MOTORS
24
33
39
49
63
78
20
27
32
40
52
64
37 : 1 (Self Locking)
25/47 29/43 33/39 37/35 42/30
69.56 54.86 43.73 35.00 26.43
0.36
0.36
0.36
0.36
0.36
0.50
0.50
0.50
0.55
0.55
37 : 1 (Self Locking)
20/52
25/47 29/43 33/39
96.2
69.6
54.9
43.7
0.36
0.36
0.36
0.36
0.55
0.55
0.55
0.55
18
15
346
346
563
97
80
129
106
37/35
35.0
0.41
0.60
42/30
26.4
0.41
0.60
78
64
97
80
129
106
157
157
298
143
143
260
108
108
197
236
236
481
215
215
420
162
162
317
393
393
709
358
358
620
270
270
468
Chart - R100-003
Page 26 of 133
Flowserve
Limitorque Actuators
10/2P
2.4
16
1.3
0.97
0.75
0.70
0.84
10/4P
4.6
24
0.67
0.50
0.67
0.48
0.82
10/4P
1.9
10.0
0.67
0.50
0.67
0.48
0.82
Motor Size
10/DC
10/DC
Chart - R100-003
10/4P 15/4P
460V - 60 Hz
2.3
2.8
12
16
0.67
1.0
0.50
0.75
0.67
0.70
0.48
0.45
0.82
0.80
15/2P
25/4P
25/2P
40/4P
3.5
26
2.0
1.49
0.83
0.68
0.79
4.0
25.5
1.6
1.19
0.73
0.57
0.8
5.2
36
3.2
2.39
0.79
0.78
0.82
5.9
38
2.6
1.94
0.80
0.66
0.79
10/2P 15/4P
230V - 60 Hz
4.8
5.6
2
32
1.3
1.0
0.97
0.75
0.75
0.70
0.70
0.45
0.84
0.80
15/2P
25/4P
25/2P
40/4P
7.0
52
2.0
1.49
0.83
0.68
0.79
8.0
51
1.6
1.19
0.73
0.57
0.8
10.4
72
3.2
2.39
0.79
0.78
0.82
11.8
76
2.6
1.94
0.80
0.66
0.79
10/2P 15/4P
575V - 60 Hz
1.9
2.2
13.0
12.8
1.33
1.0
0.97
0.75
0.75
0.70
0.70
0.45
0.84
0.80
15/2P
25/4P
25/2P
40/4P
2.8
21.0
2.0
1.49
0.83
0.68
0.79
3.2
20.0
1.6
1.19
0.73
0.57
0.8
4.2
29.0
3.3
2.39
0.79
0.78
0.82
15/DC
125V DC
9.4
50
1.083
0.81
0.69
25/DC
15/DC
250V DC
4.7
25
1.083
0.81
0.69
25/DC
14.5
82
1.805
1.35
0.75
7.5
42
1.805
1.35
0.71
Page 27 of 133
Flowserve
Limitorque Actuators
4P Motors
2P Motors
60Hz RPM
50Hz RPM
19
16
Worm Ratio
Spur Ratio 20/52
Overall Ratio 88.40
Start Eff.
0.36
Stall Eff.
0.50
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
19
16
795
795
1308
23
19
23/49
72.43
0.36
0.50
3 PHASE MOTORS
30
38
46
53
61
76
89
25
31
38
44
50
62
74
34 : 1 (Self Locking)
27/45 31/41 34/38 37/35 40/32
56.67 44.97 38.00 32.16 27.20
0.36
0.36
0.36
0.36
0.36
0.50
0.50
0.55
0.55
0.55
34 : 1 (Self Locking)
20/52 23/49
27/45 31/41 34/38
88.40 72.43
56.67 44.97 38.00
0.36
0.36
0.36
0.36
0.41
0.55
0.55
0.60
0.60
0.60
61
50
244
244
443
510
510
1003
391
391
733
816
816
1700
587
587
1212
125
103
37/35
32.16
0.41
0.60
40/32
27.20
0.41
0.60
89
74
106
87
125
103
389
389
673
329
329
569
278
278
481
623
623
1140
527
527
965
446
446
816
934
934
1938
791
791
1640
669
669
1387
76
62
Start
MRVS
Stall
Start
404
25/2P
MRVS
404
Stall
796
Start
40/4P
MRVS
Stall
Start
647
40/2P1
MRVS
647
Stall
1349
Start
60/4P
MRVS
Stall
Start
60/2P1
MRVS
Stall
1For SMB's use on Postion Seat Applications ONLY, for SB's Torque Seating is permitted.
For SBs use a 0.9 Application Factor on the Output Torque.
25/4P
106
87
Chart - R100-004
Page 28 of 133
Flowserve
Limitorque Actuators
25/4P
4.0
25.5
1.6
1.19
0.73
0.57
0.80
25/4P
8.0
51
1.6
1.19
0.73
0.57
0.80
25/4P
3.2
20.0
1.6
1.19
0.73
0.57
0.80
Motor Size
25/DC
25/DC
Chart - R100-004
25/2P 40/4P
460V - 60 Hz
5.2
5.9
36
38
3.2
2.6
2.39
1.94
0.79
0.80
0.78
0.66
0.82
0.79
40/2P
60/4P
60/2P
8.0
61
5.3
3.95
0.84
0.76
0.74
7.5
48
3.9
2.91
0.77
0.61
0.78
11.4
94.3
7.8
5.82
25/2P 40/4P
230V - 60 Hz
10.4
11.8
72
76
3.2
2.6
2.39
1.94
0.79
0.80
0.78
0.66
0.82
0.79
40/2P
60/4P
16
122
5.3
3.95
0.84
0.76
0.74
15
96
3.9
2.91
0.77
0.61
0.78
60/4P
60/2P
7.2
48.0
4.0
2.91
0.77
0.61
0.78
9.1
76.3
7.8
5.82
40/DC
125V DC
24
104
2.89
2.16
0.76
40/DC
250V DC
11
82
2.89
2.16
0.72
Page 29 of 133
Flowserve
Limitorque Actuators
4P Motors
2P Motors
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
60Hz RPM
50Hz RPM
40/4P
40/2P
60/4P
60/2P
80/4P
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
3 PHASE MOTORS
24
30
39
47
60
76
96
117
151
19
25
32
39
49
62
79
96
124
33:1 (Self Locking)
13.3:1 (Non-Locking)
22/48 26/44 30/40
22/48 26/44 30/40
72.00 55.85 44.00
29.02 22.51 17.73
0.36
0.36
0.36
0.36
0.54
0.54
0.50
0.50
0.50
0.55
0.85
0.85
33:1 (Self Locking)
13.3:1 (Non-Locking)
22/48 26/44
22/48 26/44
72.00 55.85
29.02 22.51
0.36
0.36
0.41
0.54
0.55
0.55
0.60
0.90
24
19
1036
1036
1764
1555
1555
2916
1950
2073
3348
76
62
486
486
937
729
729
1549
972
972
1779
MRVS
1608
80/2P
Stall
3072
1For SMB's use on Postion Seat Applications ONLY, for SB's Torque Seating is permitted.
For SBs use a 0.9 Application Factor on the Output Torque.
1
96
79
383
383
739
117
96
151
124
475
475
871
486
486
1013
713
713
1480
729
729
1722
951
972
951
1741
972
2026
574
574
1220
766
766
1402
Chart - R100-005
Page 30 of 133
Flowserve
Limitorque Actuators
40/4P
5.9
38
2.6
1.94
0.80
0.66
0.79
40/4P
11.8
76
2.6
1.94
0.80
0.66
0.79
40/4P
4.7
30.0
2.6
1.94
0.80
0.66
0.79
Chart - R100-005
40/2P 60/4P
460V - 60 Hz
8.0
7.5
61
48
5.3
3.9
3.95
2.91
0.84
0.77
0.76
0.61
0.74
0.78
60/2P
80/4P
80/2P
11.4
94.3
7.8
5.82
10.6
60
5.2
3.88
0.81
0.57
0.74
15.1
116
10.3
7.68
40/2P 60/4P
230V - 60 Hz
16
15
122
96
5.3
3.9
3.95
2.91
0.84
0.77
0.76
0.61
0.74
0.78
80/4P
21.2
120
5.2
3.88
0.81
0.57
0.74
80/4P
8.5
48.0
5.20
3.88
0.81
0.57
0.74
Page 31 of 133
Flowserve
Limitorque Actuators
60Hz RPM
50Hz RPM
4P Motors
2P Motors
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Stall Eff.
60Hz RPM
50Hz RPM
60/4P
60/2P
80/4P
80/2P
100/4P
100/2P
150/4P
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
3 PHASE MOTORS
24
30
36
48
60
74
93
20
24
30
40
50
61
77
41:1 (Self Locking)
16:1 (Non-Locking)
22/38 25/35 28/32
22/38 25/35 28/32
70.82 57.40 46.86
27.64 22.40 18.29
0.36
0.36
0.36
0.54
0.59
0.59
0.60
0.60
0.60
0.90
0.90
0.90
41:1 (Self Locking)
22/38 25/35 28/32
70.82 57.40 46.86
0.36
0.41
0.41
0.60
0.60
0.60
24
20
1529
1529
3442
2039
2039
3952
2549
2549
4929
3824
3824
7776
150/2P1
74
61
792
792
1633
1152
1152
2390
1057
1057
1875
1536
1536
2811
1321
1321
2339
1921
1921
3093
1982
1982
3689
2881
MRVS
3824
3530
2881
Stall
7223
5855
4779
1For SMB's use on Postion Seat Applications ONLY, for SB's Torque Seating is permitted.
For SBs use a 0.9 Application Factor on the Output Torque.
Chart - R100-006
Page 32 of 133
93
77
647
647
1333
123
101
152
125
186
153
16:1 (Non-Locking)
22/38 25/35 28/32
27.64 22.40 18.29
0.59
0.63
0.63
0.95
0.95
0.95
123
101
152
125
186
153
978
978
2232
846
846
1809
691
691
1477
1304
1304
2625
1128
1128
2128
921
921
1737
1630
1630
2888
1411
1411
2341
1152
1152
1911
2445
2116
1728
2445
4463
2116
3618
1728
2953
863
863
1531
1078
1078
1909
1618
1618
3012
Flowserve
Limitorque Actuators
60/4P
9.0
60
4.0
2.98
0.78
0.68
0.78
60/4P
14
119
4.0
2.98
0.78
0.68
0.78
60/4P
Chart - R100-006
60/2P 80/4P
460V - 60 Hz
11.4
10.6
94.3
60
7.8
5.2
5.82
3.88
0.84
0.81
0.76
0.57
0.82
0.74
60/2P 80/4P
230V - 60 Hz
22.8
21.2
189
120
7.8
5.2
5.82
3.88
0.84
0.81
0.76
0.57
0.82
0.74
60/2P 80/4P
575V - 60 Hz
8.5
48.0
5.2
3.88
0.81
0.57
0.74
15.1
116
10.3
7.68
30.2
232
10.3
7.68
12.1
93.0
10.3
7.68
10
84.4
6.6
4.92
0.89
0.70
0.75
20
169
6.6
4.92
0.89
0.70
0.75
8
67.5
6.6
4.92
0.89
0.70
0.75
Page 33 of 133
18.4
143
13
9.69
0.86
0.76
36.8
286
13.0
9.69
0.86
0.76
14.7
114.0
13.0
9.69
0.86
0.76
19.5
130.0
9.9
7.38
0.82
0.62
39.0
260
9.9
7.38
0.82
0.62
25.7
195
19.2
14.32
0.85
0.86
51.4
390
19.2
14.32
0.85
0.86
15.6
104.0
9.9
7.38
0.82
0.62
Flowserve
Limitorque Actuators
13
11
18
15
Worm Ratio
Spur Ratio 20/52 25/47
2P/4P Motors Overall Ratio 127.40 92.12
Start Eff.
0.36
0.36
Stall Eff.
0.55
0.55
60Hz RPM
50Hz RPM
13
11
4586
4586
8128
18
15
3316
3316
5877
23
19
29/43
72.66
0.36
0.55
23
19
2615
2615
4635
3 PHASE MOTORS
31
37
42
47
25
30
34
39
49:1 (Self Locking)
22/50 25/47 27/45 29/43
111.36 92.12 81.67 72.66
0.36
0.36
0.36
0.36
0.60
0.60
0.60
0.60
OUTPUT TORQUE (Ft-Lbs)
31
37
42
47
25
30
34
39
59
48
66
54
84
69
33/39
57.91
0.36
0.60
35/37
51.80
0.36
0.60
23/49
40.48
0.59
0.95
59
48
66
54
84
69
95
78
121
99
143
118
169
139
1864
1864
3419
2388
2388
4230
2107
2107
3733
1774
1774
2944
1496
1496
2482
1265
1265
2099
2797
2797
5284
3582
3582
6537
3161
3161
5769
2662
2662
4550
2244
2244
3836
1898
1898
3244
3729
3729
7086
4776
4776
8768
4214
4214
7737
3549
3549
6102
2992
2992
5144
2530
2530
4351
4662
4662
9169
5970
5970
11344
5268
5268
10011
4437
4437
7895
3740
3740
6656
3163
3163
5629
Start
MRVS
Stall
Start
4009
3316
2940
2615
2084
100/2P
MRVS
4009
3316
2940
2615
2084
Stall
7350
6080
5390
4795
3822
Start
6879
4974
3923
150/4P
MRVS
6879
4974
3923
Stall
12823 9272
7313
Start
6013
4974
4410
3923
3127
150/2P
MRVS
6013
4974
4410
3923
3127
Stall
11359 9396
8330
7411
5907
Start
8300
6632
5231
200/4P
MRVS
9172
6632
5231
Stall
16466 11907 9391
Start
8018
6632
5880
5231
4169
200/2P
MRVS
8018
6632
5880
5231
4169
Stall
15235 12602 11172 9939
7922
Start
8290
6538
250/4P
MRVS
8290
6538
Stall
14946 11788
Start
8290
7350
6538
5211
250/2P
MRVS
8290
7350
6538
5211
Stall
16305 14455 12860 10250
For SBs use a 0.9 Application Factor on the Output Torque.
100/4P
Chart - R100-007
95
121
143
78
99
118
19:1 (Non-Locking)
25/47 29/43 32/40
35.72 28.17 23.75
0.59
0.63
0.63
0.95
0.95
0.95
169
139
35/37
20.09
0.63
0.95
Page 34 of 133
Flowserve
Limitorque Actuators
WEIGHTS (Lbs)
SMB NCU
1910
SB NCU
2705
All Nuclear Safety Related Applications are to be referred to our Lynchburg Headquarters
MOTOR RATINGS
Motor Size (Ft. Lb.)
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Chart - R100-007
Page 35 of 133
Flowserve
Limitorque Actuators
SMB-5 & 5T
Max. Stem Diam. - SMB-5T Bore & KW - 8.00", 2 x 3/4 KW
SMB-5 Threaded - 6.25"
Thrust Rating - SMB-5 500,000 Lbs.
Mounting Base - Special - Non standard
60Hz RPM
50Hz RPM
12
10
Worm Ratio
Spur Ratio 1.48/1.39
2P/4P Motors Overall Ratio 146.06
Start Eff.
0.36
Stall Eff.
0.60
60Hz RPM
50Hz RPM
150/4P
150/2P
200/4P
200/2P
250/4P
250/2P
300/4P
300/2P
350/4P
350/2P
400/2P
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Chart - R100-008
12
10
7887
7887
16037
3 PHASE MOTORS
23
31
19
25
71:1 (Self Locking)
1.48/1.87 1.48/1.39 1.48/1.05
196.50
146.06
110.33
0.36
0.36
0.36
0.65
0.65
0.65
17
14
17
14
34
28
1.36/1.05
101.39
0.36
0.65
43
35
51
55
42
46
43.1 (Self Locking)
1.60/1.15 1.36/1.15 1.36/1.05
79.12
67.25
61.40
0.41
0.41
0.41
0.65
0.65
0.65
34
28
43
35
51
42
55
46
10610
10610
21713
7887
7887
16140
5958
5958
12192
5474
5474
11203
4865
4865
8743
4135
4135
7431
3776
3776
6785
14147
14147
29121
10516
10516
21646
7944
7944
16351
7299
7299
15026
6487
6487
11726
5514
5514
9967
5035
5035
9100
17684
17684
37679
13145
13145
28007
9930
9930
21157
9124
9124
19441
8109
8109
15171
6893
6893
12896
6293
6293
11774
15774
15774
33704
11916
11916
25460
10949
10949
23395
9731
9731
18257
8271
8271
15518
7552
7552
14169
18403
18403
37027
13902
13902
27970
15888
15888
34424
12774
12774
25702
14599
14599
31633
11353
11353
20057
12975
12975
24685
9650
9650
17048
11029
11029
20983
8811
8811
15566
10070
10070
19158
10516
10516
20595
13145
13145
25853
15774
15774
29358
18403
18403
35493
Page 36 of 133
Flowserve
Limitorque Actuators
SMB-5 & 5T
SMB-5T NCU
SMB-5 NCU
WEIGHTS (Lbs)
3375
3375
All Nuclear Safety Related Applications are to be referred to our Lynchburg Headquarters
3 PHASE / 60 Hz MOTOR RATINGS*
Motor Size (Ft. Lb.)
150/4P
150/2P
12.5
115.0
9.9
7.4
24.6
239.0
19.6
14.6
250/4P
250/2P
460V - 60 Hz
25.6
43.5
183.0
391.0
16.2
33.0
12.1
24.8
300/4P
300/2P
350/4P
350/2P
48.1
468.0
39.4
29.6
46.5
441.0
39.3
29.3
36.0
280.0
23.0
17.2
60.0
536.0
46.0
34.3
400/2P
71.0
629.0
52.9
39.5
460V - 60 Hz
Chart - R100-008
Page 37 of 133
Flowserve
Limitorque Actuators
L120-10
Max. Stem Diam. - B4 (Drive 1) - 1.0", 1/4 x 3/32 KW
A1 (Drive 2) - 1.25"
BL (Drive 3) - 1.25" 6 SAE Splines
BL (Drive 3) - 1.25" 38 Involute Splines
Thrust Rating - 10,000 Lbs. / 4,500 Kg
60Hz RPM
50Hz RPM
12
10
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Worm Ratio
2P Motors
Spur Ratio
Overall Ratio
Start Eff.
* High speed, locking gearset
8P & 4P
Motors
60Hz RPM
50Hz RPM
RPM
5/8P
5/4P
5/2P
7.5/4P
7.5/2P
Chart - R120-001
3 PHASE MOTORS
24
29
37
50
58
73
100
20
24
30
41
47
60
82
34 : 1 (Self Locking)
17 : 1 (Non-Locking)
22/30 17/35 19/33 22/30 26/26 19/33 22/30 26/26
46.36 70.00 59.05 46.36 34.00 29.53 23.18 17.00
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
34 : 1 (Self Locking)
19/33 22/30 26/26
59.05 46.36 34.00
0.45
0.45
0.45
18
15
115
95
126*
104*
17:1
19/33
29.53
0.50
34:1
29/23
26.98
0.45
Start
MRVS
3/4P
Stall
Mod -100
Mod - 600
Start
MRVS
5/8P
Stall
Mod -100
Mod - 600
Start
MRVS
5/4P
Stall
Mod -100
Mod - 600
Start
5/2P
MRVS
Stall
Start
MRVS
7.5/4P
Stall
Mod -100
Mod - 600
Start
7.5/2P
MRVS
Stall
* High speed, locking gearset
3/4P
17/35
70.00
0.35
Start
MRVS
Stall
Mod -100
Mod - 600
Start
MRVS
Stall
Mod -100
Mod - 600
Start
MRVS
Stall
Mod -100
Mod - 600
Start
MRVS
Stall
Start
MRVS
Stall
Mod -100
Mod - 600
Start
MRVS
Stall
10
15
100
109
134
90
80
83
83
101
74
66
100
138
169
90
80
100
117
142
90
80
91
91
112
81
72
100
134
163
90
80
67
67
82
60
53
98
98
120
89
78
Page 38 of 133
82
25
25
30
147
121
200
165
252
208
17 :1 (Non-Locking)
22/30 26/26 29/23
23.18 17.00 13.49
0.50
0.50
0.50
126*
104*
147
121
200
165
252
208
68
68
83
65
65
79
47
47
58
38
38
46
100
106
130
100
102
125
75
75
92
59
59
73
95
104*
121
165
208
73
73
89
57
57
70
42
42
51
100
132
161
100
118
130
100
104
127
84
93
102
76
76
93
61
68
75
73
73
90
60
60
74
58
58
70
42
42
52
33
33
41
100
164
200
100
120
147
100
116
142
94
94
116
91
91
111
67
67
82
53
53
65
Flowserve
Motor Size (Ft-Lbs)
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
3/4P
3.4
10
0.19
0.14
36
0.47
0.87
5/8P
4.0
9.0
0.17
0.13
31
0.30
0.58
3/4P
1.4
4.0
0.19
0.14
36
0.47
0.87
5/8P
1.6
3.6
0.17
0.13
31
0.30
0.58
3/4P
1.8
5
0.19
0.15
36
0.47
0.87
5/8P
2
4.5
0.14
0.10
23
0.29
0.58
3/4P
3.8
11.1
0.19
0.14
36
0.47
0.87
S
5/8P
4.4
10.0
0.17
0.13
31
0.30
0.58
U
60 Hz RPM
50 Hz RPM
10
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
MRVS
Stall
Start
MRVS
Stall
Chart - R120-001
Limitorque Actuators
L120-10
3 PHASE MOTOR RATINGS
230V - 60 Hz
5/4P
5/2P 7.5/4P 7.5/2P 3/4P
3.4
3.2
3.4
4.8
1.7
11.0
22
15.0
26.0
5.0
0.33
0.67
0.5
1.0
0.19
0.24
0.5
0.37
0.75
0.14
51
64
62
74
36
0.40
0.68
0.50
0.61
0.47
0.89
0.85
0.86
0.86
0.87
575V - 60 Hz
5/4P
5/2P 7.5/4P 7.5/2P 3/4P
1.4
1.3
1.4
1.9
1.7
4.4
8.8
6
10.4
5.0
0.33
0.67
0.5
1.0
0.16
0.24
0.5
0.37
0.75
0.11
51
64
62
74
40
0.40
0.68
0.50
0.61
0.50
0.89
0.85
0.86
0.86
0.86
400V - 50 Hz
5/4P
5/2P 7.5/4P 7.5/2P 3/4P
1.9
1.6
1.8
2.4
2.2
6
10
6
13.0
4.5
0.27
0.55
0.40
0.80
0.17
0.20
0.41
0.30
0.60
0.13
35
61
54
69
31
0.48
0.64
0.52
0.57
0.30
0.89
0.88
0.86
0.86
0.58
208V - 60 Hz
5/4P
5/2P 7.5/4P 7.5/2P
3.8
3.6
3.8
5.3
12.2
24.3
17.0
29.0
0.33
0.67
0.50
1.00
0.24
0.50
0.37
0.75
51
64
62
74
0.40
0.68
0.50
0.61
0.89
0.85
0.86
0.86
R
P
P
N
5/8P
2
4.5
0.17
0.13
31
0.30
0.58
5/8P
2
4.0
0.14
0.10
25
0.31
0.57
5/8P
2.2
4.5
0.14
0.10
20
0.27
0.59
460V - 60 Hz
5/4P
5/2P
1.7
1.6
5.5
11.0
0.33
0.67
0.24
0.5
51
64
0.40
0.68
0.89
0.85
380V - 50 Hz
5/4P
5/2P
1.7
1.5
5.0
10.0
0.27
0.55
0.20
0.41
40
64
0.53
0.68
0.89
0.88
415V - 50 Hz
5/4P
5/2P
2.2
1.8
6.0
10.0
0.27
0.55
0.20
0.41
32
61
0.46
0.64
0.89
0.88
7.5/4P 7.5/2P
1.7
2.4
7.5
13.0
0.5
1.0
0.37
0.75
62
74
0.50
0.61
0.86
0.86
7.5/4P 7.5/2P
1.5
2.1
6.0
13.0
0.40
0.80
0.30
0.60
58
72
0.57
0.7
0.86
0.86
7.5/4P 7.5/2P
2
2.7
6.5
14.0
0.40
0.80
0.30
0.60
50
62
0.50
0.50
0.87
0.87
115V - 60 Hz
5
10
9.6
12.3
36
57
0.33
0.66
0.25
0.49
39
54
0.57
0.66
0.95
0.89
Page 39 of 133
220V - 50 Hz
5
10
4.8
6.1
18
28.5
0.28
0.56
0.21
0.42
32
45
0.57
0.66
0.95
0.89
Flowserve
L120-10
Limitorque Actuators
RPM
2
5
7.5
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Stall
Start
Stall
Start
Stall
DC Motor Ratings
Motor Size (Ft-Lbs)
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
7.5/4P
3.0
16.0
0.5
0.37
58
0.53
0.80
2
1.5
21.5
0.15
125vdc
5
3.6
21.5
0.33
7.5
5.5
41
0.5
2
0.8
9.5
0.15
250vdc
5
1.8
9.5
0.33
7.5
2.8
24
0.5
Drive 1
Controls
NCU
BIC
UEC/Clamshell
Torque Setting
Output Torque (FT-LBS)
Top HW
100
115
140
Side HW
112
127
152
WEIGHTS (Lbs)
Drive 2
Top HW
Side HW
107
119
122
134
147
159
Chart - R120-001
Page 40 of 133
Flowserve
Limitorque Actuators
L120-20
RPM
Start
MRVS
7.5/4P
Stall
Mod-100
Mod-600
Start
7.5/2P
MRVS
Stall
Start
MRVS
10/8P
Stall
Mod-100
Mod-600
Start
MRVS
15/4P
Stall
Mod-100
Mod-600
Start
15/2P
MRVS
Stall
* High speed, locking ratio
Chart - R120-002
10
200
235
288
180
160
15
82
61
61
75
95
104*
121
165
208
120
120
147
116
116
142
95
95
117
91
91
111
67
67
82
53
53
65
200
234
286
192
192
235
184
184
225
135
135
165
107
107
131
178
178
218
160
142
200
281
343
180
160
200
206
252
180
160
Page 41 of 133
200
224
273
175
175
214
129
129
157
200
331
404
200
243
297
Flowserve
Limitorque Actuators
L120-20
7.5/4P
3.4
15.0
0.5
0.37
62
0.50
0.86
7.5/4P
1.4
6.0
0.5
0.37
62
0.50
0.86
7.5/4P
1.8
6.0
0.40
0.30
54
0.52
0.86
7.5/4P
3.8
17.0
0.5
0.37
62
0.50
0.86
42
P
60 Hz RPM
50 Hz RPM
10
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
MRVS
Stall
Start
MRVS
Stall
Chart - R120-002
460V - 60 Hz
10/8P 15/4P
3.0
3.1
6.5
15.0
0.32
1.0
0.24
0.75
39
69.0
0.34
0.49
0.58
0.83
380V - 50 Hz
10/8P 15/4P
2.5
2.7
6.5
14.0
0.28
0.80
0.20
0.60
40
64
0.35
0.5
0.58
0.83
415V - 50 Hz
10/8P 15/4P
3.5
4.0
6.5
16.0
0.28
0.80
0.20
0.60
35
52
0.30
0.42
0.53
0.85
15/2P
4.5
27.0
2.0
1.53
75
0.60
0.85
15/2P
4.0
25.0
1.6
1.2
73
0.66
0.86
15/2P
5.0
27.0
1.60
1.20
67
0.58
0.88
115V - 60 Hz
5
10
9.6
12.3
36
57
0.33
0.66
0.25
0.49
39
54
0.57
0.66
0.95
0.89
Page 42 of 133
220V - 50 Hz
5
10
4.8
6.1
18
28.5
0.28
0.56
0.21
0.42
32
54
0.57
0.66
0.95
0.89
Flowserve
L120-20
Limitorque Actuators
5/8P
5/4P
7.5/4P
Start
MRVS
Stall
Mod -100
Mod - 600
Start
MRVS
Stall
Mod -100
Mod - 600
Start
MRVS
Stall
Mod-100
Mod-600
93
123
150
90
80
70
93
114
70
63
117
155
190
105
94
170
227
277
153
140
10
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Stall
Start
Stall
DC Motor Ratings
Motor Size (Ft-Lbs)
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
78
103
126
78
70
112
150
184
101
90
57
75
92
57
52
83
110
135
75
67
7.5/4P
3.0
16.0
0.5
0.37
58
0.53
0.80
RPM
7.5
99
131
160
90
80
143
191
234
129
117
125vdc
7.5
10
5.5
6.8
41
41
0.5
0.75
250vdc
7.5
10
2.8
3.8
24
20
0.5
0.75
Drive 1
Controls
NCU
BIC
UEC/Clamshell
Top HW
140
155
180
Side HW
158
173
198
WEIGHTS (Lbs)
Drive 2
Top HW
Side HW
153
171
168
186
193
211
Chart - R120-002
Page 43 of 133
Flowserve
60Hz RPM
50Hz RPM
4P Motors
2P Motors
15/2P
25/4P
25/2P
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
RPM
15/4P
15/2P
25/4P
25/2P
Chart - R120-003
3 PHASE MOTORS
31
36
50
61
72
100
123
25
30
41
50
60
82
101
34:1 (Self Locking)
17:1 (Non-Locking)
17/33 19/31 21/29 25/25 19/31 21/29 25/25
66.00 55.47 46.95 34.00 27.74 23.48 17.00
0.40
0.40
0.45
0.45
0.50
0.50
0.50
34:1 (Self Locking)
17:1
17/33 19/31 21/29 25/25 19/31
66.00 55.47 46.95 34.00 27.74
0.40
0.40
0.45
0.47
0.50
26
21
60Hz RPM
50Hz RPM
15/4P
Limitorque Actuators
L120-40
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
127*
105*
34:1
28/22
30.55
0.45
21
400
400
488
360
320
400
620
757
360
320
Page 44 of 133
145
119
200
165
254
210
17:1 (Non-Locking)
21/29 25/25 28/22
23.48 17.00 13.36
0.50
0.50
0.50
145
119
200
165
254
210
209
209
256
151
151
185
119
119
145
301
301
368
218
218
266
171
171
209
101
105*
119
165
210
220
220
269
214
214
262
186
186
228
135
135
165
106
106
129
317
317
387
274
274
354
268
268
328
194
194
237
152
152
186
Flowserve
15/4P
5.00
35.60
1.00
0.75
64
0.60
0.82
15/4P
2.6
19.0
0.83
0.62
53
0.60
0.82
15/4P
5.8
42.0
1.00
0.75
64
0.60
0.82
48
R
RPM
10
15
25
Limitorque Actuators
L120-40
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Stall
Start
Stall
Start
Stall
DC Motor Ratings
Motor Size (Ft-Lbs)
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
10
6.80
41.00
0.75
15/4P
2.00
11.50
1.00
0.75
64
0.60
0.82
15/4P
3.60
16.50
0.83
0.62
53
0.60
0.82
575V - 60 Hz
15/2P 25/4P
3.20
3.60
20.00 22.80
2.00
1.60
1.50
1.20
72
73
0.68
0.53
0.84
0.72
415V - 50 Hz
15/2P 25/4P
5.00
5.35
32.20 33.00
1.67
1.40
1.25
1.04
60
61
0.68
0.53
0.84
0.72
25/2P
3.60
27.30
3.20
2.39
85
0.79
0.85
25/2P
4.80
33.00
2.70
2.01
71
0.79
0.85
112
25/25
17.00
0.50
67
153
107
245
159
364
125vdc
250vdc
15
25
10
15
25
9.60
17.00
3.80
4.80
45.00
48.50 102.00 20.00 31.00
8.00
1.00
1.80
0.75
1.00
1.80
Top HW
190
205
230
Side HW
216
231
256
Top HW
212
227
252
3
240
280
Drive 2
Side HW
238
253
278
3.5
280
320
4
320
360
4.5
360
400
5
-
Chart - R120-003
Page 45 of 133
Flowserve
60Hz RPM
50Hz RPM
4P Motors
2P Motors
60Hz RPM
50Hz RPM
40/4P
40/2P
60/4P
60/2P
3 PHASE MOTORS
30
37
48
60
73
25
30
39
49
60
Worm Ratio
38:1 (Self Locking)
Spur Ratio 21/39 24/36 27/33 31/29
Overall Ratio 70.57 57.00 46.44 35.55
Start Eff.
0.40
0.40
0.28
0.33
Worm Ratio
38:1 (Locking)
Spur Ratio
21/39 24/36 27/33
Overall Ratio
70.57 57.00 46.44
Start Eff.
0.40
0.40
0.40
24
20
40/2P
60/4P
60/2P
Chart - R120-004
96
79
31/29
35.55
0.40
119
98
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
20
850
859
1050
765
680
Page 46 of 133
146
121
191
158
19:1 (Non-Locking)
24/36 27/33 31/29
28.50 23.22 17.77
0.46
0.48
0.48
RPM
40/4P
Limitorque Actuators
L120-85
146
121
191
158
390
397
530
311
311
415
575
656
874
475
513
684
98
121
158
390
396
529
315
334
445
225
261
348
575
623
831
490
525
699
390
411
547
Flowserve
RPM
15
25
40
60
Output RPM
60 / 50 Hz
24 / 20
30 / 25
37 / 30
48 / 39
60 / 49
73 / 60
96 / 79
119 / 98
146 / 121
191 / 158
Chart - R120-004
Limitorque Actuators
L120-85
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Stall
Start
Stall
Start
Stall
Start
Stall
Ratio
70.57
57.00
46.44
35.55
57.00
46.44
35.55
28.50
23.22
17.77
60/2P
17.1
120.5
8.0
5.80
84
0.76
0.82
40/4P
4.7
30.4
2.6
1.94
80
0.66
0.79
60/2P
13.0
104.0
6.7
5.0
86
0.76
0.85
40/4P
5.4
34.8
2.2
1.64
75
0.58
0.83
575V - 60 Hz
40/2P 60/4P
6.4
7.2
48.8
52.0
5.3
4.0
3.95
2.98
84
75
0.76
0.56
0.74
0.76
415V - 50 Hz
40/2P 60/4P
7.3
8.2
56.0
59.5
4.4
3.3
3.28
2.46
83
73
0.89
0.58
0.75
0.79
60/2P
9.1
75.4
7.8
5.82
84
0.76
0.82
60/2P
10.4
86.4
6.7
5.0
86
0.76
0.85
67
82
107
19:1 (Non-Locking)
24/36 27/33 31/29
28.50 23.22 17.77
0.50
0.50
0.50
193
158
121
212
173
132
321
262
201
462
376
288
356
288
225
816
658
515
684
552
432
1566
1264
989
Page 47 of 133
Flowserve
Limitorque Actuators
L120-85
WEIGHTS (Lbs)
Controls
NCU
BIC
UEC/Clamshell
60/2P Motor
Torque Setting
Output Torque (FT-lBS)
Drive 1
275
295
315
Drive 2
345
365
405
Add 125# To The Weights Above
* Factory torque switch settings are made during the actuator torque test and may differ from the nominal values above.
Chart - R120-004
Page 48 of 133
Flowserve
60Hz RPM
50Hz RPM
4P Motors
2P Motors
60Hz RPM
50Hz RPM
60/4P
60/2P
80/4P
80/2P
60/2P
80/4P
80/2P
Chart - R120-005
3 PHASE MOTORS
30
39
48
60
76
97
119
151
192
25
32
39
49
63
80
98
124
158
33:1 (Self Locking)
13.33:1 (Non-Locking)
22/48 26/44 30/40 34/36 22/48 26/44 30/40 34/36
72.01 55.84 43.89 34.95 29.09 22.55 17.73 14.12
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
33:1 (Self Locking)
13.33:1 (Non-Locking)
22/48 26/44 30/40 34/36 22/48 26/44 30/40
72.01 55.84 43.89 34.95 29.09 22.55 17.73
0.40
0.40
0.40
0.40
0.50
0.50
0.50
24
19
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
RPM
60/4P
Limitorque Actuators
L120-190
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
Start
MRVS
Stall
Mod-100
Mod-600
Start
MRVS
Stall
Page 49 of 133
151
124
192
158
670
670
967
527
527
761
974
974
1407
766
766
1106
98
335
335
447
124
158
691
691
998
442
442
590
536
536
774
421
421
608
1005
1005
1452
779
779
1126
613
613
885
Flowserve
RPM
60
80
Limitorque Actuators
L120-190
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Stall
Start
Stall
80/2P
15.1
116.4
10.3
7.68
84
0.79
0.83
60/4P
7.2
52.0
4.0
2.98
75
0.56
0.76
80/2P
18.0
128.0
8.6
6.4
83
0.79
0.86
60/4P
8.2
59.5
3.3
2.46
73
0.58
0.79
575V - 60 Hz
60/2P 80/4P
9.1
8.5
75.4
48.0
8.0
5.2
5.82
3.88
84
81
0.76
0.57
0.82
0.74
415V - 50 Hz
60/2P 80/4P
10.4
9.7
86.4
55.0
6.7
4.3
5.0
3.21
86
82
0.76
0.58
0.85
0.75
80/2P
12.1
92.8
10.3
7.68
84
0.79
0.83
80/2P
13.8
106.0
8.6
6.4
83
0.79
0.86
107
1.33
17.73
0.50
426
974
567
1135
Chart - R120-005
Page 50 of 133
Flowserve
Limitorque Actuators
L120-190
WEIGHTS (Lbs)
L120-190
L120S-190
Controls
NCU
INT
UEC
NCU
INT
UEC
Drive 1
520
586
586
-
Drive 2
520
586
586
740
806
806
STANDARD
HEAVY
1
300
1.5
420
2
550
2.5
690
3
840
3.5
1140
4
1440
1440
4.5
4.75
1740
1900
Note 1 - Factory torque switch settings are made during the actuator torque test and may differ from the nominal values above.
Note 2 - The above settings apply to both Standard and Heavy spring packs. The Standard pack may be used up to 1500 foot
pounds and the Heavy pack from 1500-1900 foot pounds
Chart - R120-005
Page 51 of 133
Flowserve
60Hz RPM
50Hz RPM
4P Motors
2P Motors
60Hz RPM
50Hz RPM
100/4P
100/2P
150/4P
150/2P
100/2P
150/4P
150/2P
Chart - R120-006
3 PHASE MOTORS
24
30
37
49
60
74
96
123
152
186
20
24
31
40
50
61
79
101
125
154
41:1 (Self Locking)
16:1 (Non-Locking)
19/41 22/38 25/35 28/32 19/41 22/38 25/35 28/32
88.53 70.93 57.40 46.74
34.56 27.68 22.40 18.24
0.40
0.40
0.40
0.40
0.45
0.45
0.50
0.50
41:1 (Self Locking)
16:1 (Non-Locking)
19/41 22/38 25/35 28/32 19/41 22/38 25/35 28/32
88.53 70.93 57.40 46.74
34.56 27.68 22.40 18.24
0.40
0.40
0.40
0.40
0.45
0.45
0.50
0.50
19
16
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
RPM
100/4P
Limitorque Actuators
L120-420
Start
MRVS
Stall
Mod-100
Start
MRVS
Stall
Start
MRVS
Stall
Mod-100
Start
MRVS
Stall
Page 52 of 133
123
101
152
125
186
154
1222
1222
1901
1099
1099
1709
895
895
1392
1850
1850
2877
1663
1663
2587
1354
1354
2107
61
952
952
1374
79
775
775
1119
101
125
154
1467
1467
2282
1322
1322
1910
1221 978
1221 978
1899 1521
1077
1077
1556
879
879
1367
716
716
1113
2221
2221
3455
1848
1848
2874
1331
1331
2070
1083
1083
1685
1480
1480
2307
Flowserve
RPM
100
150
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Stall
Start
Stall
Chart - R120-006
Limitorque Actuators
L120-420
575V - 60 Hz
150/2P 100/4P 100/2P 150/4P
25.7
8.0
15.0
16.0
195.0
67.5
114.0 104.0
19.2
6.6
13.0
9.9
14.30
4.92
9.70
7.40
89
0.70
0.75
415V - 50 Hz
150/2P 100/4P 100/2P 150/4P
25.0
9.1
17.0
18.0
207.0
77.0
131.0 119.0
16.0
5.5
10.8
8.3
12.0
4.1
8.1
6.2
86
0.73
0.75
150/2P
21.0
156.0
19.2
14.30
150/2P
23.5
179.0
16.0
12.0
104
1.14
18.24
0.50
730
1459
1094
2189
Page 53 of 133
Flowserve
Limitorque Actuators
L120-420
WEIGHTS (Lbs)
L120-420
L120S-420
Controls
NCU
INT
NCU
INT
Drive 1
1130
1220
-
Drive 2
1130
1220
1540
1630
Chart - R120-006
Page 54 of 133
Flowserve
Max. Stem Diam. - B4 (Drive 1) - 4.50", 1 x 1/2 KW
A1 (Drive 2) - 5.0"
Thrust Rating - 250,000 Lbs. / 112,500 Kg
Mounting Base - FA40 (MSS)
60Hz RPM
50Hz RPM
2P/4P Motors
Limitorque Actuators
L120-800
14
11
18
15
Worm Ratio
Spur Ratio 20/51 25/47
Overall Ratio 124.95 92.12
Start Eff.
0.35
0.40
60Hz RPM
50Hz RPM
150/4P
150/2P
200/4P
200/2P
250/4P
250/2P
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
23
19
29/43
72.62
0.40
3 PHASE MOTORS
31
37
42
47
25
30
34
39
49:1 (Self Locking)
22/50 25/47 27/45 29/43
111.36 92.12 81.67 72.62
0.40
0.40
0.40
0.40
59
48
66
54
84
69
33/39
57.87
0.40
35/37
51.80
0.40
23/49
40.48
0.45
95
121
143
78
99
118
19:1 (Non-Locking)
25/47 29/43 32/40
35.72 28.17 23.75
0.45
0.45
0.55
169
139
35/37
20.09
0.55
95
78
121
99
143
118
169
139
2387
2387
3978
1882
1882
3137
1940
1940
3233
1641
1641
2735
3226
3226
5377
2544
2544
4240
2622
2622
4369
2218
2218
3696
3949
3949
6582
3115
3115
5191
3209
3209
5349
2715
2715
4525
200/2P 250/2P
36.6
44.2
304
368.0
22
27.1
16.4
20.2
Chart - R120-007
Page 55 of 133
Flowserve
L120-800
Limitorque Actuators
WEIGHTS (Lbs)
L120-800
L120S-800
Controls
NCU
NCU
Drive 1
1700
-
Drive 2
1700
2520
Chart - R120-007
Page 56 of 133
Flowserve
60Hz RPM
50Hz RPM
2P/4P Motors
12
10
Worm Ratio
Spur Ratio 1.48/1.39
Overall Ratio 145.57
Start Eff.
0.40
60Hz RPM
50Hz RPM
200/4P
200/2P
250/4P
250/2P
300/4P
300/2P
350/4P
350/2P
Limitorque Actuators
L120-2000
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
Start
MRVS
Stall
3 PHASE MOTORS
23
31
19
26
71:1 (Self Locking)
1.48/1.87 1.48/1.39 1.48/1.05
195.64
145.57
109.80
0.40
0.40
0.40
17
14
34
28
1.36/1.05
101.43
0.40
43
35
50
55
42
46
43.1 (Self Locking)
1.60/1.15 1.36/1.15 1.36/1.05
79.12
67.43
61.43
0.40
0.40
0.40
50
42
55
46
8815
8815
15181
8143
8143
14024
6352
6352
10939
5413
5413
9323
4932
4932
8493
10791
10791
18585
9969
9969
17168
7776
7776
13392
6627
6627
11413
6037
6037
10398
13242
13242
22805
12232
12232
21067
9542
9542
16433
8132
8132
14005
7408
7408
12759
15337
15337
26413
14168
14168
24400
11051
11051
19033
9419
9419
16221
8581
8581
14778
Chart - R120-008
250/4P
25.6
183.0
16.2
12.2
200/2P
37.4
332.0
26.4
20.0
300/2P
48.1
468.0
39.4
29.8
Page 57 of 133
Flowserve
L120-2000
Limitorque Actuators
L120-2000
Controls
NCU
WEIGHTS (Lbs)
Drive 1
3300
Drive 2
3300
4.5
-
Chart - R120-008
Page 58 of 133
Flowserve
QX
Limitorque Actuators
POWER SUPPLY
Suitable for AC power supplies from 100vAC 575vAC including: 1/60/115, 1/60/230, 1/50/115,
1/50/220, 3/60/208, 3/60/230, 3/50/380, 3/60/380,
3/50/400, 3/50/415, 3/50/440, 3/60/460, 3/50/515,
3/60/575. (Note: de-rating for reduced voltage is not
required, provided supply voltage is 90vAC or
greater. Maximum voltage may not exceed 264vAC)
Also available as 24 & 48 VDC. Incoming DC power
can range from 21.6 volts to 52.8 volts (-10% of
24VDC and +10% of 48VDC).
QX-1
QX-2
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
(in)
1.41
35
2.00
50
1.00
1.41
35
2.00
50
1.00
mm)
25
25
(sec)
5-20
8-30
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
100
136
90
122
80
250
340
225
306
200
Modulating - Continuous
(NM)
(Ft lbs)
109
70
272
175
(Ft lbs)
(NM)
33
44
83
112
(Ft lbs)
(NM)
(Ft lbs)
(NM)
50
68
200
271
125
170
500
678
STEM CAPACITY
B4/B4E Max bore / Max square key
B4/B4E Max bore / Max rec key
B4/B4E Max bore / key
OPERATING TIME
(for 90 degree travel, adjustable)note 1
TORQUE RATINGS
On/Off
Modulating - 100 Starts/Hr
Stall
Chart R110-001
Page 59 of 133
Flowserve
QX
Limitorque Actuators
QX-1
QX-2
(lbs)
(KG)
45
21
45
21
(in.)
(lbs)
200:1
26%
3
15
200:1
26%
3
37
50
50
MSS type
FA10
FA10
ISO type
F10
F10
WEIGHT
HANDWHEEL
Ratio
Eff
Diameter
Input for full rating (lbs)
Turns for 90 degrees output
MOUNTING BASE - STANDARD
MSS-FA07
ISO-F07
MSS-FA07
ISO-F07
100
136
.875 / 3/16 sq key
100
136
1.1875 / 1/4 sq key
200
272
1.1875 / 1/4 sq key
Base
On/Off torque rating
Max bore / Max square key
Max bore / Max rec key
Max bore / key
Max square shaft
Max square shaft
Max double D (diameter)
Max double D (diameter)
(Ft lbs)
(NM)
(in)
MOTOR RATINGS
1/60/115, 3/60/208, 1/50/115, 1/50/220,
1/60/230, 3/60/230
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
1.5
7.0
0.16
0.12
69
0.6
0.65
Chart R110-001
Page 60 of 133
2.5
9.0
0.26
0.18
73
0.6
0.65
Flowserve
QX
24/48 VDC
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
Limitorque Actuators
QX-1
QX-2
0.75
3.5
0.16
0.12
64
0.6
0.65
1.25
4.5
0.26
0.18
68
0.6
0.65
5.6/2.8
27/13.5
0.16
0.12
64
Not Applicable
Not Applicable
8.5/4.3
40/20
0.26
0.18
68
Not Appicable
Not Appicable
(sec)
10
10
(sec)
15
15
(sec)
N/A
30
(sec)
N/A
N/A
(sec)
N/A
60
(sec)
N/A
N/A
Page 61 of 133
Flowserve
QX
Limitorque Actuators
POWER SUPPLY
Suitable for AC power supplies from 100vAC 575vAC including: 1/60/115, 1/60/230, 1/50/115,
1/50/220, 3/60/208, 3/60/230, 3/50/380, 3/60/380,
3/50/400, 3/50/415, 3/50/440, 3/60/460, 3/50/515,
3/60/575. (Note: de-rating for reduced voltage is not
required, provided supply voltage is 90vAC or
greater. Maximum voltage may not exceed 264vAC)
Also available as 24 & 48 VDC. Incoming DC power
can range from 21.6 volts to 52.8 volts (-10% of
24VDC and +10% of 48VDC).
QX-3
QX-4
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
(in)
1.75
45
2.5
64
2.00
1.75
45
2.50
64
2.00
mm)
50
50
(sec)
15-60
30-120
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
400
542
360
488
320
750
1016
675
915
600
Modulating - Continuous
(NM)
(Ft lbs)
433
280
813
525
(Ft lbs)
(NM)
133
180
250
339
(Ft lbs)
(NM)
(Ft lbs)
(NM)
N/A
N/A
800
1084
N/A
N/A
1500
2033
STEM CAPACITY
B4/B4E Max bore / Max square key
B4/B4E Max bore / Max rec key
B4/B4E Max bore / key
OPERATING TIME
(for 90 degree travel, adjustable)note 1
TORQUE RATINGS
On/Off
Modulating - 100 Starts/Hr
Stall
Chart R110-001
Page 62 of 133
Flowserve
QX
Limitorque Actuators
QX-3
QX-4
(lbs)
(KG)
80
36
80
36
(in.)
(lbs)
276:1
26%
7.5
17
276:1
26%
7.5
33
70
70
MSS type
FA12
FA14
ISO type
F12
F14
WEIGHT
HANDWHEEL
Ratio
Eff
Diameter
Input for full rating (lbs)
Turns for 90 degrees output
MOUNTING BASE - STANDARD
MSS-FA14
ISO-F14
MSS-FA12
ISO-F12
400
542
1.625 / 3/8 sq key
400
542
2.375 5/8 sq key
750
1016
2.375 5/8 sq key
Base
On/Off torque rating
Max bore / Max square key
Max bore / Max rec key
Max bore / key
Max square shaft
Max square shaft
Max double D (diameter)
Max double D (diameter)
(Ft lbs)
(NM)
(in)
MOTOR RATINGS
1/60/115, 3/60/208, 1/50/115, 1/50/220,
1/60/230, 3/60/230
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
1.5
7.0
0.16
0.12
69
0.6
0.65
Chart R110-001
Page 63 of 133
2.5
9.0
0.26
0.18
73
0.6
0.65
Flowserve
QX
24/48 VDC
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
Limitorque Actuators
QX-3
QX-4
0.75
3.5
0.16
0.12
64
0.6
0.65
1.25
4.5
0.26
0.18
68
0.6
0.65
5.6/2.8
27/13.5
0.16
0.12
64
Not Applicable
Not Applicable
8.5/4.3
40/20
0.26
0.18
68
Not Appicable
Not Appicable
(sec)
30
60
(sec)
60
60
(sec)
N/A
no change
(sec)
N/A
N/A
(sec)
N/A
120
(sec)
N/A
N/A
Page 64 of 133
Flowserve
QX
Limitorque Actuators
POWER SUPPLY
Suitable for AC power supplies from 100vAC 575vAC including: 1/60/115, 1/60/230, 1/50/115,
1/50/220, 3/60/208, 3/60/230, 3/50/380, 3/60/380,
3/50/400, 3/50/415, 3/50/440, 3/60/460, 3/50/515,
3/60/575. (Note: de-rating for reduced voltage is not
required, provided supply voltage is 90vAC or
greater. Maximum voltage may not exceed 264vAC)
Also available as 24 & 48 VDC. Incoming DC power
can range from 21.6 volts to 52.8 volts (-10% of
24VDC and +10% of 48VDC).
QX-5
STEM CAPACITY
B4/B4E Max bore / Max square key
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
(in)
1.75
45
2.50
64
2.00
mm)
50
(sec)
60-120
OPERATING TIME
(for 90 degree travel, adjustable)note 1
TORQUE RATINGS
On/Off
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
1500
2033
1350
1830
1200
Modulating - Continuous
(NM)
(Ft lbs)
1626
1050
(Ft lbs)
(NM)
500
678
(Ft lbs)
(NM)
(Ft lbs)
(NM)
N/A
N/A
3000
4067
Stall
Chart R110-001
Page 65 of 133
Flowserve
QX
Limitorque Actuators
QX-5
WEIGHT
HANDWHEEL
Ratio
Eff
Diameter
Input for full rating (lbs)
(lbs)
(KG)
80
36
(in.)
(lbs)
276:1
26%
7.5
65
70
FA14
ISO type
F14
Base
On/Off torque rating
Max bore / Max square key
Max bore / Max rec key
Max bore / key
Max square shaft
Max square shaft
Max double D (diameter)
Max double D (diameter)
MOTOR RATINGS
1/60/115, 3/60/208, 1/50/115, 1/50/220,
1/60/230, 3/60/230
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
Chart R110-001
Page 66 of 133
(Ft lbs)
(NM)
(in)
1000
1355
2.375 5/8 sq key
(in)
(mm)
(in)
mm)
(in)
mm)
2.5
9.0
0.26
0.18
73
0.6
0.65
Flowserve
QX
Limitorque Actuators
QX-5
1.25
4.5
0.26
0.18
68
0.6
0.65
24/48 VDC
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
8.5/4.3
40/20
0.26
0.18
68
Not Appicable
Not Appicable
(sec)
60
(sec)
120
(sec)
no change
(sec)
N/A
(sec)
120
(sec)
N/A
Page 67 of 133
Flowserve
QX/M
POWER SUPPLY
Limitorque Actuators
Suitable for AC power supplies from 100vAC 575vAC including: 1/60/115, 1/60/230, 1/50/115,
1/50/220, 3/60/208, 3/60/230, 3/50/380, 3/60/380,
3/50/400, 3/50/415, 3/50/440, 3/60/460, 3/50/515,
3/60/575. (Note: de-rating for reduced voltage is
not required, provided supply voltage is 90vAC or
greater. Maximum voltage may not exceed
264vAC) Also available as 24 & 48 VDC.
QX-1/M
QX-1/ML
(in)
(mm)
(in)
(mm)
(in)
(mm)
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
(in)
mm)
1.57
40
2.75
70
2.00
50
1.625 / 3/8 sq key
1.75 / 3/8x1/4 key
42 / 12x8 key
1.41
35
2.00
50
1.00
25
1.57
40
2.75
70
2.00
50
1.625 / 3/8 sq key
1.75 / 3/8x1/4 key
42 / 12x8 key
1.41
35
2.00
50
1.00
25
(lbs)
12,000
12,000
(Kn)
53
53
(RPM)
Locking
Locking
12
18
24
LOCKING/NON-LOCKING note 2
Non-locking
MAXIMUM TURNS
20
20
TORQUE RATINGS
On/Off
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Run torque (33%) - max 15 min.
Run torque (40%) - max 15 min.
Run torque (50%) - max 15 min.
Stall
Chart R110-002
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
100
136
90
122
80
109
70
52
33
44
50
68
200
271
Page 68 of 133
45
61
41
55
36
49
32
43
40
54
36
49
32
43
28
38
30
41
27
37
24
33
21
28
18
24
16
22
14
20
13
17
18
24
N/A
N/A
90
122
16
22
N/A
N/A
80
108
12
16
N/A
N/A
60
81
7
9
N/A
N/A
36
49
Flowserve
QX/M
POWER SUPPLY
Limitorque Actuators
Suitable for AC power supplies from 100vAC 575vAC including: 1/60/115, 1/60/230, 1/50/115,
1/50/220, 3/60/208, 3/60/230, 3/50/380, 3/60/380,
3/50/400, 3/50/415, 3/50/440, 3/60/460, 3/50/515,
3/60/575. (Note: de-rating for reduced voltage is
not required, provided supply voltage is 90vAC or
greater. Maximum voltage may not exceed
264vAC) Also available as 24 & 48 VDC.
QX-1/MH
QX-2/M
(in)
(mm)
(in)
(mm)
(in)
(mm)
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
(in)
mm)
1.57
40
2.75
70
2.00
50
1.625 / 3/8 sq key
1.75 / 3/8x1/4 key
42 / 12x8 key
1.41
35
2.00
50
1.00
25
1.57
40
2.75
70
2.00
50
1.625 / 3/8 sq key
1.75 / 3/8x1/4 key
42 / 12x8 key
1.41
35
2.00
50
1.00
25
(lbs)
12,000
12,000
(Kn)
53
53
(RPM)
12
18
24
1.9
LOCKING/NON-LOCKING note 2
Locking
Non-locking
Locking
MAXIMUM TURNS
20
20
TORQUE RATINGS
On/Off
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Run torque (33%) - max 15 min.
Run torque (40%) - max 15 min.
Run torque (50%) - max 15 min.
Stall
Chart R110-002
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
90
122
81
110
72
98
63
85
78
106
70
95
62
85
55
74
55
75
50
67
44
60
39
52
38
52
34
46
30
41
27
36
36
49
N/A
N/A
180
244
31
42
N/A
N/A
156
212
22
30
N/A
N/A
110
149
15
20
N/A
N/A
76
103
Page 69 of 133
250
339
225
305
200
271
175
237
83
112
125
170
500
678
Flowserve
QX/M
POWER SUPPLY
Limitorque Actuators
Suitable for AC power supplies from 100vAC 575vAC including: 1/60/115, 1/60/230, 1/50/115,
1/50/220, 3/60/208, 3/60/230, 3/50/380, 3/60/380,
3/50/400, 3/50/415, 3/50/440, 3/60/460, 3/50/515,
3/60/575. (Note: de-rating for reduced voltage is
not required, provided supply voltage is 90vAC or
greater. Maximum voltage may not exceed
264vAC) Also available as 24 & 48 VDC.
QX-3/M
QX-4/M
QX-5/M
(in)
(mm)
(in)
(mm)
(in)
(mm)
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
(in)
mm)
N/A
N/A
N/A
N/A
N/A
N/A
2.375 / 5/8 sq key
2.5 / 5/8x7/16 key
60 / 18x11 key
1.75
45
2.5
64
2.00
50
N/A
N/A
N/A
N/A
N/A
N/A
2.375 / 5/8 sq key
2.5 5/8x7/16 key
60 / 18x11 key
1.75
45
2.50
64
2.00
50
N/A
N/A
N/A
N/A
N/A
N/A
2.375 / 5/8 sq key
2.5 5/8x7/16 key
60 / 18x11 key
1.75
45
2.50
64
2.00
50
(lbs)
N/A
N/A
N/A
(Kn)
N/A
N/A
N/A
.5
.25
Locking
Locking
Locking
20
20
20
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
400
542
360
488
320
433
280
750
1016
675
915
600
813
525
1500
2033
1350
1830
1200
1626
1050
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
(Ft lbs)
(NM)
133
180
250
339
500
678
N/A
N/A
800
1084
N/A
N/A
1500
2033
N/A
N/A
3000
4067
(RPM)
LOCKING/NON-LOCKING note 2
Note 2 - locking refers to QX/M worm set. In most
cases QX/M units are used with linear type valves
where the threaded stem locks the valve
MAXIMUM TURNS
TORQUE RATINGS
On/Off
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Run torque (33%) - max 15 min.
Run torque (40%) - max 15 min.
Run torque (50%) - max 15 min.
Stall
Chart R110-002
Page 70 of 133
Flowserve
QX/M
Limitorque Actuators
QX-1/M
QX-1/ML
(lbs)
(KG)
(lbs)
(KG)
45
21
54
25
45
21
54
25
(in.)
200:1
26%
3
WEIGHT
QX/M, B4 or B4E base
QX/M, B4 or B4E base
QX/M, A1 or A1E base
QX/M, A1 or A1E base
HANDWHEEL
Ratio
Eff
Diameter
200:1
26%
50
48%
50
48%
50
48%
FA10
F10
FA10
F10
Base
On/Off torque rating
Max bore / Max square key
Max bore / Max rec key
Max bore / key
Max square shaft
Max square shaft
Max double D (diameter)
Max double D (diameter)
(Ft lbs)
(NM)
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
MSS-FA05
ISO-F05
100
136
.875 / 3/16 sq key
0.93 / 3/16x1/8 key
22 / 6x6 key
0.750
19
1.06
27
MSS-FA07
ISO-F07
100
136
1.1875 / 1/4 sq key
1.25 / 1/4x3/16 key
30 / 8x7 key
1.000
25
1.44
36
MSS-FA05
ISO-F05
100
136
.875 / 3/16 sq key
0.93 / 3/16x1/8 key
22 / 6x6 key
0.750
19
1.06
27
MSS-FA07
ISO-F07
100
136
1.1875 / 1/4 sq key
1.25 / 1/4x3/16 key
30 / 8x7 key
1.000
25
1.44
36
1.5
7.0
0.16
0.12
69
0.6
0.65
1.5
7.0
0.16
0.12
69
0.6
0.65
0.75
3.5
0.16
0.12
64
0.6
0.65
0.75
3.5
0.16
0.12
64
0.6
0.65
24/48 VDC
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
Flowserve's standard stem nut machining tolerances
Shaft Fits
English - Reference ANSI B4.1 Class RC9
Metric - Reference ANSI B4.2 Free Running Fit
Chart R110-002
Page 71 of 133
Flowserve
QX/M
Limitorque Actuators
QX-1/MH
QX-2/M
45
21
54
25
45
21
54
25
WEIGHT
QX/M, B4 or B4E base
QX/M, B4 or B4E base
QX/M, A1 or A1E base
QX/M, A1 or A1E base
(lbs)
(KG)
(lbs)
(KG)
HANDWHEEL
Ratio
Eff
Diameter
200:1
26%
50
48%
50
48%
3
200:1
26%
3
FA10
F10
FA10
F10
(in.)
50
48%
Base
On/Off torque rating
Max bore / Max square key
Max bore / Max rec key
Max bore / key
Max square shaft
Max square shaft
Max double D (diameter)
Max double D (diameter)
(Ft lbs)
(NM)
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
MSS-FA05
ISO-F05 (note 1)
100
136
.875 / 3/16 sq key
0.93 / 3/16x1/8 key
22 / 6x6 key
0.750
19
1.06
27
MSS-FA07
ISO-F07
100
136
1.1875 / 1/4 sq key
1.25 / 1/4x3/16 key
30 / 8x7 key
1.000
25
1.44
36
MSS-FA07
ISO-F07
200
272
1.1875 / 1/4 sq key
1.25 / 1/4x3/16 key
30 / 8x7 key
1.000
25
1.44
36
2.5
9.0
0.26
0.18
69
0.6
0.65
2.5
9.0
0.26
0.18
73
0.6
0.65
1.25
4.5
0.26
0.18
64
0.6
0.65
1.25
4.5
0.26
0.18
68
0.6
0.65
24/48 VDC
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
Flowserve's standard stem nut machining tolerances
Shaft Fits
English - Reference ANSI B4.1 Class RC9
Metric - Reference ANSI B4.2 Free Running Fit
Chart R110-002
Page 72 of 133
Flowserve
QX/M
Limitorque Actuators
QX-3/M
QX-4/M
QX-5/M
(lbs)
(KG)
(lbs)
(KG)
80
36
N/A
N/A
80
36
N/A
N/A
80
36
N/A
N/A
(in.)
276:1
26%
7.5
276:1
26%
7.5
276:1
26%
7.5
FA12
F12
FA14
F14
FA14
F14
MSS-FA10
ISO-F10
400
542
1.625 / 3/8 sq key
1.875 / 1/2x3/8 key
50 / 14x9 key
1.625
42
2.25
58
MSS-FA12
ISO-F12
750
1016
2.375 5/8 sq key
2.5 5/8x7/16 key
64 /18x11 key
1.750
45
2.5
64
MSS-FA12
ISO-F12
1000
1355
2.375 5/8 sq key
2.5 5/8x7/16 key
64 /18x11 key
1.750
45
2.5
64
1.5
7.0
0.16
0.12
69
0.6
0.65
2.5
9.0
0.26
0.18
73
0.6
0.65
2.5
9.0
0.26
0.18
73
0.6
0.65
0.75
3.5
0.16
0.12
64
0.6
0.65
1.25
4.5
0.26
0.18
68
0.6
0.65
1.25
4.5
0.26
0.18
68
0.6
0.65
5/2.5
23/11
0.16
0.12
64
N/A
N/A
8/4
30/15
0.26
0.18
0.68
N/A
N/A
8/4
30/15
0.26
0.18
0.68
N/A
N/A
WEIGHT
QX/M, B4 or B4E base
QX/M, B4 or B4E base
QX/M, A1 or A1E base
QX/M, A1 or A1E base
HANDWHEEL
Ratio
Eff
Diameter
Base
On/Off torque rating
Max bore / Max square key
Max bore / Max rec key
Max bore / key
Max square shaft
Max square shaft
Max double D (diameter)
Max double D (diameter)
(Ft lbs)
(NM)
(in)
(in)
(mm)
(in)
mm)
(in)
mm)
24/48 VDC
Full Load Amps (FLA)
Locked Rotor Amps (LRA)
Horsepower (HP)
Kilowatts (KW)
Efficiency @ Full Load (%)
Power Factor @ Full Load
Power Factor @ Locked Rotor
Flowserve's standard stem nut machining tolerances
Shaft Fits
English - Reference ANSI B4.1 Class RC9
Metric - Reference ANSI B4.2 Free Running Fit
Chart R110-002
Page 73 of 133
Flowserve
QX/M
Limitorque Actuators
QX-1/M
QX-1/ML
(RPM)
1.5
No change
(RPM)
1.0
No change
(RPM)
N/A
No change
(RPM)
N/A
N/A
(RPM)
N/A
No change
(RPM)
N/A
N/A
Chart R110-002
Page 74 of 133
Flowserve
QX/M
Limitorque Actuators
QX-1/MH
QX-2/M
(RPM)
No change
1.5
(RPM)
No change
1.0
(RPM)
No change
0.50
(RPM)
N/A
N/A
(RPM)
No change
0.50
(RPM)
N/A
N/A
Chart R110-002
Page 75 of 133
Flowserve
QX/M
Limitorque Actuators
QX-3/M
QX-4/M
QX-5/M
(RPM)
0.5
0.25
No change
(RPM)
0.25
0.25
0.125
(RPM)
N/A
No change
No change
(RPM)
N/A
N/A
N/A
(RPM)
N/A
0.125
0.125
(RPM)
N/A
N/A
N/A
Chart R110-002
Page 76 of 133
Flowserve
Limitorque Actuators
LY
LY-1001
STEM CAPACITY
Maximum Stem Capacity (Inches)
Maximum Stem Capacity (mm)
MOUNTING BASE - Standard
- Optional
OUTPUT TORQUE
60 Hz Operating Time (Sec.)
50 Hz Operating Time (Sec.)
On/Off Start Torque (Ft-Lbs)
LY-2001
1.125 with
2.375 with
2.375 with
1/4 x 1/8
5/8 x 5/16
5/8 x 5/16
Keyway
Keyway
Keyway
28, 6 x 3 Keyway 60, 15 x 7.5 KW 60, 15 x 7.5 KW
FA10/MSS
F10/ISO
15
18
FA14/MSS
F14/ISO
(NM)
Modulating 100 Starts/Hr (Ft-Lbs)
(NM)
Modulating 600 Starts/Hr (Ft-Lbs)
(NM)
NA
NA
NA
NA
30
60
36
72
200
270
180
243
160
216
MOTOR RATINGS
60 Hz Operating Time (Sec.)
50 Hz Operating Time (Sec.)
15
18
30
36
60
72
15
18
NA
NA
NA
NA
30
60
36
72
600
814
540
733
480
651
NA
NA
NA
NA
15
18
30
36
20
24
60
72
20
24
30
60
36
72
1200
1628
1080
1465
960
1302
30
36
LY-3001
32
0.36
6
230
44
0.36
6
316.8
40
20
75
34
90
41
Page 77 of 133
32
0.36
12
460.8
89.3
0.33
12
1179
100
45
110
50
144
65
105
48
130
59
149
68
60
72
6.0
9.0
0.13
3.1
4.5
0.13
1.28
4.0
0.13
0.64
2.0
0.13
0.51
1.6
0.13
0.29
0.99
0.05
0.7
2.2
0.108
Flowserve
LY
Limitorque Actuators
Chart - R150-001
Page 78 of 133
Flowserve
Limitorque Actuators
L75
PERFORMANCE DATA
START
MOD
TORQUE TORQUE2
MODEL
in.-lbs.
L75-10
120
in.-lbs.
120
L75-12
180
180
L75-15
L75-20
260
480
480
L75-22
720
L75-23
950
L75-25
1440
L75-30
2400
720
950
1440
2400
POWER SUPPLY
60 hz
AC
120, 240
120, 240
120, 240
120
120, 240
120, 240
120, 240
120
120
120, 240
120, 240
120, 240
120
120, 240
120, 240
120
120, 240
120, 240
120, 240
120, 240
120, 240
50 hz
AC
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
DC
12, 24
12, 24
12, 24
12, 24
12, 24
12, 24
12, 24
12, 24
12, 24
OP. TIME
(sec. for 900)
60 hz
AC
2.5
5
17
17
4
8
27
27
5
2.5
5
17
27
4
8
27
25
10
15
15
23
50 hz
AC
3
6
20
20
5
10
32
32
6
3
6
20
32
5
10
32
30
12
18
18
28
STALL
TORQUE
DC
5
15
8
25
5
15
8
25
25
DUTY
CYCLE1
10%
25%
75%
100%
10%
25%
75%
100%
20%
10%
25%
75%
100%
10%
25%
75%
75%
25%
75%
25%
75%
MANUAL
DRIVE3
WEIGHT
in.-lbs.
RATIO
EFF
Lbs
KG
150
1:1
100%
8.2
3.7
225
1:1
100%
8.2
3.7
325
1:1
100%
8.5
3.8
600
1:1
100%
9.5
4.3
900
1:1
100%
9.5
4.3
1200
1:1
100%
17.7
1800
40:1
30%
48
22
3000
40:1
30%
48
22
MOTOR RATINGS
OP. TIME
(sec. for 900)
MODEL
L75-10
L75-12
L75-15
L75-20
L75-22
L75-23
L75-25
L75-30
AC
2.5
5
17
17
4
8
27
27
5
2.5
5
17
27
4
8
27
25
10
15
15
23
DC
5
15
8
25
5
15
8
25
25
Chart - R180-001
Page 79 of 133
Flowserve
Limitorque Actuators
L270-10
Max. Stem Diam. - B4 (Drive 1) - 1.0", 1/4 x 3/32 KW
A1 (Drive 2) - 1.25"
Thrust Rating - 10,000 Lbs. / 4,500 Kg
60 PSI
80 PSI
100 PSI
RPM
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Run
Stall
Start
Run
Stall
Start
Run
Stall
Controls
NCU
Control Valve
WEIGHTS (Lbs)
Drive 1
Top HW
Side HW
100
112
115
127
Drive 2
Top HW
107
122
Side HW
119
134
5
-
Chart - R270-001
Page 80 of 133
Flowserve
Limitorque Actuators
L270-20
Max. Stem Diam. - B4 (Drive 1) - 1.875", 1/2 x 3/16 KW
A1 (Drive 2) - 2.25"
Thrust Rating - 20,000 Lbs. / 9,000 Kg
RPM
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
60 PSI
80 PSI
100 PSI
Start
Run
Stall
Start
Run
Stall
Start
Run
Stall
60 PSI
80 PSI
100 PSI
Start
Run
Stall
Start
Run
Stall
Start
Run
Stall
36
42
60
34:1 (Self Locking)
19/33 22/30 26/26
59.05 46.36 34.00
0.40
0.40
0.40
72
84
120
17:1 (Non-Locking)
19/33 22/30 26/26
29.53 23.18 17.00
0.50
0.50
0.50
47
19
52
56
23
62
75
30
83
34
14
38
41
17
45
55
22
61
100 PSI 6.9 Bar
130
3.7
70
28
77
94
38
103
117
47
129
52
21
57
69
28
76
86
34
95
100 PSI 6.9 Bar
180
5.1
Controls
NCU
Control Valve
Chart - R270-002
WEIGHTS (Lbs)
Drive 1
Top HW
Side HW
140
158
155
173
Page 81 of 133
Drive 2
Top HW
153
168
Side HW
171
186
Flowserve
L270-20
Limitorque Actuators
5
-
Chart - R270-002
Page 82 of 133
Flowserve
Limitorque Actuators
L270-40
Max. Stem Diam. - B4 (Drive 1) - 2.125", 1/2 x 3/16 KW
A1 (Drive 2) - 2.625"
Thrust Rating - 30,000 Lbs. / 13,500 Kg
60 PSI
80 PSI
100 PSI
RPM
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
Start
Run
Stall
Start
Run
Stall
Start
Run
Stall
Controls
NCU
Control Valve
WEIGHTS (Lbs)
Drive 1
Top HW
Side HW
190
216
205
231
Drive 2
Top HW
212
227
Side HW
238
253
5
-
Chart - R270-003
Page 83 of 133
Flowserve
Limitorque Actuators
L270-190
Worm Ratio
Spur Ratio
Overall Ratio
Start Eff.
60 PSI
80 PSI
100 PSI
26/44
55.85
0.40
80 PSI
100 PSI
Ratio
22.30
22.30
22.30
22.30
22.30
9.00
9.00
9.00
9.00
30/40
17.73
0.50
5 Gear
31,100
1,150
13.33:1 (Non-Locking)
34/36
38/32
42/28
14.08
11.20
8.87
0.50
0.50
0.50
RPM (DV20F)
Start
Run
Stall
Start
Run
Stall
Start
Run
Stall
Output RPM
27/45
34/57
43/72
54/90
68/114
85/141
107/178
134
169
42/28
34.95
0.40
RPM (DV10H)
Start
Run
Stall
Start
Run
Stall
Start
Run
Stall
60 PSI
107
318
152
329
317
245
473
422
355
617
134
174
121
262
252
195
376
336
282
491
169
137
96
208
200
154
298
266
224
389
100 PSI 6.9 Bar
435
12.3
178
296
186
439
380
304
566
465
422
684
100 PSI 6.9 Bar
870
24.6
Controls
NCU
Control Valve
Drive 1
520
586
Drive 2
520
586
4.5
Page 84 of 133
Flowserve
Limitorque Actuators
HBC
(inches) 1.500
(inches) 3/8 x 1/8
(inches) 0.50
Ratio
Dynamic Torque
Modulating Torque
Max. One Time Input
(motor operation only) (note 3)
1.875
2.875
1/2 x 3/16
0.625
3/4 x 1/4
0.75
70:1
200:1
70:1
200:1
Start
Run
Stall
0.30
0.30
0.27
0.30
0.27
0.30
0.30
0.27
0.30
0.27
0.35
0.35
0.30
0.35
0.30
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
445
1300
2,200
605
178
1768
520
2,992
880
242
333
707
975
1,197
1,650
453
1326
2,244
(Ft -Lbs)
(NM)
100
136
600
814
230
312
675
915
260
353
(Lbs)
(Kg)
65
30
120
55
155
71
150
69
185
85
FA25
FA25
Pos B
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
Pos A
Weight (note2)
Mounting base
HBC-2/2.86
71:1
Efficiency
Torque ratings
On/Off Torque
HBC-2
(MSS) (Note 1)
FA30
Electric Adapters-MSS
(MX)
(L120)
(SMB)
Notes:
1) Mounting base not in accordance with MSS standar
2) Add 30 pounds (14 kg) for AWWA stop when used
3) For AWWA C504 applications, manually operated
valves, the AWWA input stop is required where the
max one time input is less than 300 foot pounds
4) HBC-7 & 7M
Chart - R300-001
Page 85 of 133
Flowserve
HBC-3
Stem Capacity
Max. Bore:
Max Keyway
Minimum bore
(inches)
(inches)
(inches)
Ratio
Efficiency
Torque ratings
On/Off Torque
Dynamic Torque
Modulating Torque
Max. One Time Input
(motor operation only) (note 3)
Start
Run
Stall
HBC-3/2.86
HBC-4
HBC-4/6 HBC-4/12
3.750
4.250
7/8 x 5/16
1.50
1 x 3/8
1.875
70:1
200:1
60
360:1
720
0.30
0.27
0.30
0.27
0.27
0.30
0.27
0.30
0.27
0.27
0.35
0.30
0.35
0.30
0.30
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
5,650
12,800
7,684
2,260
17,408
5,120
3,074
4,237
6,963
9,600
5,763
13,056
(Ft -Lbs)
(NM)
510
692
200
271
1,290
1,749
240
325
120
162
(Lbs)
(Kg)
230
105
265
121
420
191
495
225
495
225
Weight (note2)
Mounting base
Limitorque Actuators
HBC
(MSS)
Pos B
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
Pos A
Electric Adapters-MSS
(MX)
(L120)
(SMB)
Notes:
1) Mounting base not in accordance with MSS standar
2) Add 30 pounds (14 kg) for AWWA stop when used
4) HBC-7 & 7M
Chart - R300-001
Page 86 of 133
Flowserve
HBC-5
Stem Capacity
Max. Bore:
Max Keyway
Minimum bore
Efficiency
Dynamic Torque
Modulating Torque
Max. One Time Input
(motor operation only) (note 3)
Start
Run
Stall
(Ft -Lbs)
(NM)
(Lbs)
(Kg)
HBC-6
HBC-6/13.6
6.500
7.500
1.5 x 1/2
2.50
1.75 x 5/8
3.0
390:1
780:1
66:1
897
0.30
0.27
0.27
0.30
0.25
0.30
0.27
0.27
0.30
0.25
0.35
0.30
0.30
0.35
0.30
19,583
46,000
26,633
7,833
62,560
18,400
10,653
14,687
25,024
34,500
19,975
46,920
1,830
2,481
340
461
170
230
3,900
5,288
319
433
560
255
635
289
635
289
1,300
591
1,375
625
(MSS)
HBC-5/12
65:1
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
Weight (note2)
Mounting base
HBC-5/6
(inches)
(inches)
(inches)
Ratio
Torque ratings
On/Off Torque
Limitorque Actuators
HBC
Note 1
Note 1
Pos B
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
Pos A
Electric Adapters-MSS
(MX)
(L120)
(SMB)
Notes:
1) Mounting base not in accordance with MSS standar
2) Add 30 pounds (14 kg) for AWWA stop when used
3) For AWWA C504 applications, manually operated
valves, the AWWA input stop is required where the
max one time input is less than 300 foot pounds
4) HBC-7 & 7M
Chart - R300-001
Page 87 of 133
Flowserve
Limitorque Actuators
HBC
HBC-7
Stem Capacity
Max. Bore:
Max Keyway
Minimum bore
(inches)
(inches)
(inches)
Ratio
Efficiency
Torque ratings
On/Off Torque
Dynamic Torque
Modulating Torque
Max. One Time Input
(motor operation only) (note 3)
Start
Run
Stall
HBC-7M HBC-7M/19.2
9 (note 4)
2.5 x 7/8 (note 4)
2.5" (note 4)
69
1325
50
950
0.30
0.25
0.30
0.25
0.30
0.25
0.30
0.25
0.35
0.30
0.35
0.30
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
63,333
93,000
86,133
25,333
126,480
37,200
34,453
47,500
50,592
69,750
64,600
94,860
(Ft -Lbs)
(NM)
6,600
8,950
375
509
10,000
13,560
613
831
(Lbs)
(Kg)
2,100
955
2,380
1082
2,100
955
2,380
1082
Weight (note2)
Mounting base
HBC-7/19.2
(MSS)
Note 1
Pos A
Pos B
Pos B
Pos A
Pos B
Pos A
Pos A
Pos B
Electric Adapters-MSS
(MX)
(L120)
(SMB)
Notes:
1) Mounting base not in accordance with MSS standar
2) Add 30 pounds (14 kg) for AWWA stop when used
4) HBC-7 & 7M
Metrric -
Chart - R300-001
Page 88 of 133
Flowserve
Limitorque Actuators
B320
B320-20
B320-40
B320-50
B320-70
B320-80
B320-90
2.36
2.87
3.54
4.02
5.12
6.0
60
73
90
102
130
73, 19 Key
89, 22 Key
152
5.44, 1-1/4
Key
138, 32 Key
3.0, 3/4x1/2
3.7, 7/8x5/8
STEM CAPACITY
Max Stem Diam.
(In.)
(mm)
(In.)
(mm)
(In.)
(mm)
61, 16 Key
2.52
5/8x7/16
64, 16x11 Key
114, 24 Key
140, 32x22
Key
Metric -
(Lbs)
40,000
80,000
100,000
150,000
200,000
325,000
Max. Thrust
Normal rating
(KN)
180
360
450
675
900
1463
Max. Thrust
Special rating
(Lbs)3
25,000
45,000
65,000
90,000
110,000
325,000
Max. Thrust
Special rating
(KN)3
113
203
293
405
495
1,463
(Lbs)
51
68
143
254
418
745
23
31
65
115
190
339
Weight w/ SGA
(Lbs)
80
97
198
309
474
875
36
44
90
140
215
398
FA14/F14
FA16/F16
FA25/F25
FA30/F30
FA36/F35
FA40/F404
(Kg)
(Kg)
Base type
(MSS/ISO)
The special rating should be applied to all torque seated valves for power plant applications when temp exceeds 500 0 F, or when temp is
unknown.
4)
B320-90 FA40 base has special bolt hole size
3
MOTORIZED RATINGS
Ratio
Efficiency
On/Off Torque
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
1,500
2,034
1,000
1,355
600
813
(Ft.-Lbs.)
(NM)
3,000
4,067
4,500
6,101
6,500
8,813
6.2
0.9
8,000
10,846
530
400
1,000
440
2,000
1,330
1,985
1,917
718
542
1,355
596
2,711
1,803
2,691
2,599
(Ft-Lbs)
420
1050
700
2100
3150
4550
5600
(Nm)
(Ft-Lbs)
(Nm)
569
300
406
1423
750
1017
948
500
678
2846
1500
2034
4270
2250
3051
6169
3250
4407
7592
4000
5424
168
420
280
840
1260
1820
2240
227
569
379
1138
1708
2467
3036
750
1,800
1,250
3,750
6,000
8,000
8,000
1,017
2,440
1,695
5,084
8,135
10,847
10,846
(Nm)
MANUAL RATINGS
Output Torque
(Ft.-Lbs.)
(NM)
Spur Ratio
Spur Efficiency
Max. One Time
Input w/SGA
Chart - R320-001
6.3
10.8
10.8
10.3
17.5
0.9
0.9
0.8
0.8
0.8
0.8
0.8
(Ft.-Lbs.) 195
145
370
160
395
260
230
150
235
175
300
230
137
(NM)
196
501
216
536
353
311
203
318
237
406
311
185
264
Page 89 of 133
Flowserve
Limitorque Actuators
A110RM
A111RM
A110RSM
A111RSM
(inches)
5.5
5.5
5.5
5.5
(mm)
140
140
140
140
STEM CAPACITY
Max Stem Diam.
(inches)
(mm)
(inches)
(mm)
(Lbs)
247,300
247,300
359,700
359,700
(KN)
1100
1100
1600
1600
(Lbs)
698
698
698
698
(Kg)
310
310
310
310
FA40/F40
FA40/F40
FA40/F40
FA40/F40
Ratio
5:1
5.8:1
5:1
5.8:1
Efficiency
0.85
0.85
0.85
0.85
(Ft. lbs)
11,800
8,850
11,800
8,850
(NM)
16,000
12,000
16,000
12,000
(Ft. lbs)
4278
3687
4278
3678
(NM)
5818
5014
5818
5014
8,260
11,200
6,195
8,400
8,260
11,200
6,195
8,400
Weight
Base type
(MSS/ISO)
MOTORIZED RATINGS
On/Off Torque
(Ft. lbs)
(NM)
MOTOR ADAPTERS
MX
L120
(MSS) L120-85, 190, 420 L120-85, 190, 420 L120-85, 190, 420 L120-85, 190, 420
Chart - R320-002
Page 90 of 133
MX-85, 140,150
Flowserve
Limitorque Actuators
MT bevels
MT-2
MT-3
MT-4
2.87
3.54
6.0
73
90
152
61, 16 Key
73, 19 Key
138, 32 Key
3.0, 3/4x1/2
5.50, 1-1/4x7/8
STEM CAPACITY
Max Stem Diam.
(in)
(mm)
(in)
(mm)
(in)
(mm)
2.52
5/8x7/16
Weight w/ SGA
Base type
(Lbs)
65,000
100,000
150000
(KN)
290
450
675
(Lbs)
95
218
745
(KN)
43
99
339
(Lbs)
124
273
875
(KN)
56
124
398
FA16/F16
FA25/F25
(MSS)
1)
FA30/F30
4:1
6:1
4:1
6:1
Efficiency
0.9
0.9
0.9
0.9
(Ft-Lbs)
1,500
1,000
3,000
4500
(NM)
2,034
1,355
4,067
6101
(Ft-Lbs)
1,000
440
2,000
1,330
1917
(NM)
1,355
596
2,711
1,803
2599
(Ft-Lbs)
(NM)
(Ft-Lbs)
(NM)
1050
1423
750
1017
700
948
500
678
2100
2846
1500
2034
3150
4270
2250
3051
Modulating Continuous
(Ft-Lbs)
420
280
840
1260
(NM)
569
379
1138
1708
1,800
2,440
1,250
1,695
3,750
5,084
6000
8135
10.8
17.5
0.9
0.8
0.8
On/Off Torque
6.2
0.9
MANUAL RATINGS
Output Torque
(Ft-Lbs)
(NM)
Spur Ratio
Spur Efficiency
Max. One Time
Input w/SGA
(Ft-Lbs)
370
160
230
150
137
(NM)
501
216
311
203
185
Chart - R340-001
20, 40, 85
20, 40, 85
00
Page 91 of 133
85, 140
85, 190, 420
0
Flowserve
Limitorque Actuators
WTR
NOTE: Red = unavailable
WTRC 10
WTRA 12
STEM CAPCITY & WEIGHTS
2 Piece - Max. Bore & Sq. Key (In.) 2.25, 3/8 Key
(mm)
2 Piece - Max Bore & Rect. Key (In.) 2.25, 5/8x7/16
(mm) 58, 16x10 Key
2 Piece - Minimum Bore (In.)
0.75
(mm)
19
1 Piece - Max Bore & Sq Key (In.)
(mm)
1 Piece - Max Bore & Rect. Key (In.)
(mm)
1 Piece - Minimum Bore (In.)
(mm)
Weight (Lbs)
33
(Kg)
15
WTRC Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
(NM)
Dynamic Torque (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
WTRA Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
(NM)
Dynamic Torque (Ft.-Lbs.)
(NM)
Modulating - 100 Starts/Hr (Ft.-Lbs.)
(NM)
Modulating - 600 Starts/Hr (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
Chart - R330-001
15
21
10
50
15
72
0.25
1,000
1,356
400
543
150
203
0.25
0.25
1,200
1,627
0.25
12
55
21
55
0.31
1,200
1,627
480
651
900
1,220
840
1,139
150
203
0.31
0.31
1,200
1,627
0.31
Page 92 of 133
15/S1.69
21/S1.69
28
36
15/S1.69
122
28
70
0.23
0.28
1,800
2,441
720
977
200
271
125
170
300
407
0.23
0.28
0.26
125
170
0.26
3,600
4,882
21/S1.69
93
36
53
0.29
0.31
2,100
2,848
840
1,139
1,575
2,136
1,470
1,993
2,100
2,848
28/S3.7
259
2,800
3,797
1,120
1,520
2,100
2,848
250
339
28/S3.7
36/S3.7
36/S3.7
196
0.29
3,600
4,882
1,440
1,953
2,700
3,661
2,520
3,417
150
203
450
610
0.29
0.31
175
237
0.29
3,600
4,882
Flowserve
Limitorque Actuators
WTR
WTRC 40
40/S3.71
WTRA 48
48/S3.71
STEM CAPCITY & WEIGHTS
2 Piece - Max. Bore & Sq. Key (In.)
3.75, 3/4 Key
(mm)
2 Piece - Max Bore & Rect. Key (In.) 3.75, 1.0x3/4 Key
(mm)
96, 28x16 Key
2 Piece - Minimum Bore (In.)
1.125
(mm)
28.5
1 Piece - Max Bore & Sq Key (In.)
(mm)
1 Piece - Max Bore & Rect. Key (In.)
(mm)
1 Piece - Minimum Bore (In.)
(mm)
Weight (Lbs)
128
170
(Kg)
58
77
WTRC Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
40
70
(NM)
WTRA Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
0.26
0.28
500
678
0.28
48
55
600
814
0.26
0.28
72
55
0.29
0.32
550
746
0.32
0.26
150
203
0.26
7,200
9,763
4,800
6,509
1,920
2,604
3,600
4,882
3,360
4,556
(NM)
(NM)
Modulating - 100 Starts/Hr (Ft.-Lbs.)
(NM)
Modulating - 600 Starts/Hr (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
150
203
48/S3.71
204
0.32
60/S4.64
325
6,000
8,136
2,400
3,256
4,800
6,509
Chart - R330-001
60
70
4,000
5,424
1,600
2,171
60/S4.64
72/S4.64
40/S3.71
259
0.28
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
60
72
72/S4.64
255
0.29
7,200
9,763
2,880
3,905
5,400
7,322
5,040
6,834
175
237
800
1,085
200
271
0.29
0.32
0.29
4,800
6,509
Page 93 of 133
7,200
9,763
150
130
150/S8.25
130/S8.25
150/S8.25
495
0.28
0.24
12,000
16,272
4,800
6,513
1,200
175
1,627
237
0.28
0.24
15,000
20,340
130
60
130/S8.25
495
0.32
0.28
13,000
17,628
5,200
7,051
9,750
13,221
9,100
12,340
1,100
200
1,492
271
0.32
0.28
13,000
17,628
Flowserve
430
430
WTRC -
430
65
430/S6.3
410
430/S10.8
702
430/S24.8
1612
0.30
0.25
1,800
2,441
0.26
15,000
20,340
6,000
8,141
300
407
185
251
NA
NA
NA
NA
NA
85
115
0.34
0.30
0.28
0.28
Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
309
140
(NM)
Dynamic Torque (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
WTRA Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
430/S10.8
430/S10.8
430/S24.8
430/S24.8
430
65
430/S6.3
410
430/S10.8
702
430/S24.8
1612
0.30
0.25
1,800
2,441
0.26
15,000
20,340
6,000
8,136
11,250
15,255
10,500
14,238
300
407
185
251
NA
NA
NA
NA
NA
NA
NA
NA
NA
85
115
0.34
0.30
0.28
0.28
(NM)
(NM)
Modulating - 100 Starts/Hr (Ft.-Lbs.)
(NM)
Modulating - 600 Starts/Hr (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
430/S6.3
430/S6.3
22,000
29,832
Chart - R330-001
Limitorque Actuators
WTR
Page 94 of 133
22,000
29,832
Flowserve
Limitorque Actuators
WTR
NOTE: Red = unavailable
WTRC WTRA STEM CAPCITY & WEIGHTS
2 Piece - Max. Bore & Sq. Key (In.)
(mm)
2 Piece - Max Bore & Rect. Key (In.)
(mm)
2 Piece - Minimum Bore (In.)
(mm)
1 Piece - Max Bore & Sq Key (In.)
(mm)
1 Piece - Max Bore & Rect. Key (In.)
(mm)
1 Piece - Minimum Bore (In.)
(mm)
Weight (Lbs)
(Kg)
450
450
WTRC -
450
68
450/S4.3
292
450/S10.3
700
450/S30
2040
0.30
0.26
2,400
3,254
0.28
21,000
28,476
8,400
11,398
600
814
300
407
NA
NA
NA
NA
NA
100
136
0.34
0.31
0.30
0.28
Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
412
187
(NM)
Dynamic Torque (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
WTRA Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
450/S30
450/S30
452
205
450
68
450/S4.3
292
450/S10.3
700
450/S30
2040
0.30
0.26
2,400
3,254
0.28
21,000
28,476
8,400
11,390
15,750
21,357
14,700
19,933
600
814
300
407
NA
NA
NA
NA
NA
NA
NA
NA
NA
100
136
0.34
0.31
0.30
0.28
(NM)
Chart - R330-001
450/S10.3
450/S10.3
32,000
43,392
450/S4.3
450/S4.3
Page 95 of 133
32,000
43,392
Flowserve
Limitorque Actuators
WTR
NOTE: Red = unavailable
WTRC WTRA STEM CAPCITY & WEIGHTS
2 Piece - Max. Bore & Sq. Key (In.)
(mm)
2 Piece - Max Bore & Rect. Key (In.)
(mm)
2 Piece - Minimum Bore (In.)
(mm)
1 Piece - Max Bore & Sq Key (In.)
(mm)
1 Piece - Max Bore & Rect. Key (In.)
(mm)
1 Piece - Minimum Bore (In.)
(mm)
Weight (Lbs)
(Kg)
500
500
WTRC -
500
69
500/S4.3
297
500/S10.3
711
500/S30
2070
0.33
0.29
3,200
4,339
0.30
30,000
40,680
12,000
16,282
800
1,085
370
502
NA
NA
NA
NA
NA
130
176
0.36
0.33
0.31
0.30
Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
(NM)
WTRA Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
558
253
500
69
500/S4.3
297
500/S10.3
711
500/S30
1463
0.33
0.29
3,200
4,339
0.30
30,000
40,680
12,000
16,272
22,500
30,510
21,000
28,476
800
1,085
370
502
NA
NA
NA
NA
NA
NA
NA
NA
NA
130
176
0.36
0.33
0.31
0.30
(NM)
Chart - R330-001
500/S30
500/S30
41,000
55,596
500/S10.3
500/S10.3
500/S4.3
500/S4.3
Page 96 of 133
41,000
55,596
Flowserve
575
575
WTRC -
575
60
575/S5.2
309
575/S7.8
468
575/S38.9
2338
0.34
0.30
9,000
12,204
0.30
70,000
94,920
28,000
37,992
1,800
2,441
1,300
1,763
NA
NA
NA
NA
NA
270
366
0.38
0.33
0.33
0.31
Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
(NM)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
WTRA Ratio
Motorized
Efficiency
On/Off Torque (Ft.-Lbs.)
575/S7.8
575/S7.8
575/S38.9
575/S38.9
89,000
120,684
575
60
575/S5.2
309
575/S7.8
468
575/S38.9
2338
0.34
0.30
9,000
12,204
0.30
70,000
94,920
28,000
37,968
52,500
71,190
49,000
66,444
1,800
2,441
1,300
1,763
NA
NA
NA
NA
NA
NA
NA
NA
NA
270
366
0.38
0.33
0.33
0.31
(NM)
Dynamic Torque (Ft.-Lbs.)
(NM)
Modulating - 100 Starts/Hr (Ft.-Lbs.)
(NM)
Modulating - 600 Starts/Hr (Ft.-Lbs.)
(NM)
Max. One Time Input (Ft.-Lbs.)
(NM)
Manual
Efficiency
Output Torque (Ft.-Lbs.)
(NM)
575/S5.2
575/S5.2
Chart - R330-001
Limitorque Actuators
WTR
Page 97 of 133
89,000
120,684
Flowserve
Limitorque Actuators
PTA
PTA-12
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
1.25
(mm)
32
(inches)
5/16
(mm)
8
(inches) 5/16 x 1/4
(mm)
10 x 8
(inches)
0.625
(mm)
16
1.75
44
2.5
63.5
7/16
10
5/8
16
1/2 x 3/8
5/8 x 7/16
12 x 8
0.75
18 x 11
0.75
19
19
Ratio
42:1
60:1
210:1
60:1
210:1
Efficiency
0.27
0.27
0.24
0.27
0.24
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
1600
2170
1000
1356
665
1600
2170
1000
1356
665
502
902
902
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
Weight
880
1193
555
753
370
(Lbs)
(Kg)
150
203
195
264
62
79
195
264
62
79
880
1600
1600
1193
2170
2170
27
13
38
17
50
23
38
17
50
23
(MSS)
FA12
FA14
FA14
(ISO)
F12
F14
F14
(MSS)
(ISO)
FA12, FA16
F12, F16
FA12, FA16
F12, F16
FA12, FA16
F12, F16
FA12, FA16
F12, F16
Pos A
Pos A
Pos A
N/A
N/A
N/A
Electric Adapters-MSS
05
(MX)
(L120)
(SMB)
05, 10
10
05
05, 10
10
05
* - No longer available
Chart - R23801-001
Page 98 of 133
Flowserve
Limitorque Actuators
PTA
PTA-18*
PTA-32*
PTA-32/3.1*
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
3.00
75
4.0
110
5/8
-
7/8
-
7/8 x 5/8
1 x 3/4
20 x 12
7/8
28 x 16
7/8
22
22
Ratio
65:1
60:1
186:1
Efficiency
0.30
0.35
0.34
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
1,800
2,441
1,620
2,197
1,440
3,200
4,339
3,200
4,339
3,200
1,953
4,339
(Ft.-Lbs.)
(NM)
1,260
3,200
1,709
4,339
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
190
257
Weight
(Lbs)
(Kg)
619
838
208
282
1,800
3,200
2,441
4,339
61
28
166
76
203
93
(MSS)
FA14
FA16
(ISO)
F14
F16
(MSS)
(ISO)
FA12
F12
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Electric Adapters-MSS
05, 10
10
20
20
05
10
(MX)
(L120)
(SMB)
* - No longer available
Chart - R23801-001
Page 99 of 133
Flowserve
Limitorque Actuators
PTA
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
2.625
65
3.3
86
5/8
-
3/4
-
3/4 x 1/2
7/8 X 5/8
18 X 11
none (solid nut)
25 X 14
Ratio
68:1
238:1
68:1
238:1
Efficiency
0.30
0.27
0.30
0.27
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
3,000
4,068
1,875
2,543
1,260
1,709
1,709
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
338
458
(Lbs)
(Kg)
74
34
Weight
3,000
4,068
1,875
2,543
1,260
107
145
338
458
107
145
3,000
3,000
4,068
4,068
86
40
74
34
86
40
(MSS)
FA16
FA16
(ISO)
F16
F16
(MSS)
(ISO)
FA14
F14
FA14
F14
Pos A
Pos A
N/A
N/A
Electric Adapters-MSS
05
10
05, 10, 20
10, 20
05
10
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
2.95
75
3.6
92
1/2
-
5/8
-
5/8 X 7/16
3/4 x 1/2
20 X 12
none (solid nut)
25 X 14
none (solid nut)
Ratio
88:1
308:1
88:1
308:1
Efficiency
0.30
0.27
0.30
0.27
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
4,000
5,424
2,500
3,390
1,680
2,278
2,278
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
338
458
(Lbs)
(Kg)
107
49
Weight
4,000
5,424
2,500
3,390
1,680
107
145
338
458
107
145
4,000
4,000
5,424
5,424
119
55
107
49
119
55
(MSS)
FA16
FA16
(ISO)
F16
F16
(MSS)
(ISO)
FA25
F25
FA25
F25
FA25
F25
FA25
F25
Pos A
Pos A
N/A
N/A
Electric Adapters-MSS
05
10
05, 10, 20
10, 20
05
10
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
PTA-50/2
PTA-50/1
PTA-60
PTA-60/3.1 PTA-60/6.6
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
2.95
(mm)
75
(inches)
1/2
(mm)
(inches) 5/8 X 7/16
(mm)
20 X 12
(inches) none (solid nut)
(mm) none (solid nut)
3.6
92
4.0
110
5/8
-
7/8
-
3/4 x 1/2
1 x 3/4
25 X 14
28 x 16
1
25.4
Ratio
183:1
183:1
60:1
184:1
393:1
Efficiency
0.31
0.31
0.32
0.30
0.30
5,310
7,200
3,319
4,500
2,230
5,310
7,200
3,319
4,500
2,230
8,800
11,930
7920
10737
7040
3,024
3,024
9,544
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
6,160
8351
206
279
206
279
5,310
5,310
8,800
7,200
7,200
11,930
98
45
98
45
(MSS)
FA25
FA25
FA25
(ISO)
F25
F25
F25
Pos A
Pos A
Pos B
Pos B
Pos B
N/A
N/A
Pos A
Pos A
Pos A
05, 10
10
05, 10
10
20, 40, 85
20, 40, 85
05, 10, 20
10, 20
05, 10
10
Manual Operation
Weight
(Lbs)
(Kg)
712
965
169
77
248
336
186
84
119
161
186
84
(MSS)
(ISO)
Electric Adapters-MSS
(MX)
(L120)
(SMB)
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
4.0
110
7/8
1 x 3/4
28 x 16
7/8
22
Ratio
60:1
186:1
378:1
Efficiency
0.35
0.34
0.34
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
8,000
10,848
7,200
9,763
6,400
(Ft.-Lbs.)
(NM)
5,600
7,594
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
680
838
(Lbs)
(Kg)
166
76
Weight
8,678
208
282
102
138
8,000
10,848
203
93
(MSS)
FA25
(ISO)
F25
(MSS)
(ISO)
FA16
F16
203
93
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
05, 10, 20
10, 20
05
10
Electric Adapters-MSS
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
5.5
140
1-1/4
1-1/4 x 7/8
36 x 20
1.25
32
Ratio
60:1
186:1
378:1
648:1
Efficiency
0.28
0.26
0.26
0.26
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
12,000
16,270
12,000
16,270
12,000
(Ft.-Lbs.)
(NM)
10,500
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
Weight
(Lbs)
(Kg)
16,270
14,236
1,639
844
518
303
283
149
161
87
312
142
312
142
12,000
16,270
275
124
312
142
(MSS)
FA30
(ISO)
F30
(MSS)
(ISO)
FA35
F35
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
10, 20, 40
10, 20,40
05,10,20
10,20,40
05,10
10
Electric Adapters-MSS
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
5.5
140
1-1/4
1-1/4 x 7/8
36 x 20
1.25
32
Ratio
60:1
186:1
378:1
648:1
Efficiency
0.28
0.26
0.26
0.26
283
149
161
87
312
142
312
142
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
15,000
20,338
13,500
18,303
12,000
(Ft.-Lbs.)
(NM)
10,500
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
Weight
(Lbs)
(Kg)
16,270
14,236
1,639
844
518
303
15,000
20,338
275
124
312
142
(MSS)
FA35
(ISO)
F35
(MSS)
(ISO)
FA30
F30
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
10, 20, 40
10, 20,40
05,10,20
10,20, 40
05,10
10
Electric Adapters-MSS
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
PTA-130
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
5.5"
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
140
1-1/4
1-1/2 x 1
36 x 20
1.25
32
Ratio
61:1
180:1
357:1
542:1
Efficiency
.33
0.30
0.30
0.30
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
15,400
20,880
13,860
16,270
12,270
(Ft.-Lbs.)
(NM)
10,780
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
Weight
(Lbs)
(Kg)
16,704
14,616
1,275
1,728
473
647
239
324
162
220
270
122
305
138
305
138
305
138
(MSS)
FA30 / FA35
(Standard base is drilled for both FA30 and FA35)
(ISO)
F30 / F35
(Standard base is drilled for both F30 and F35)
(MSS)
(ISO)
FA40
F40
Pos B
Pos B
Pos B
Pos B
Pos A, consult
factory for leadtime
Pos A, consult
factory for leadtime
Pos A, consult
factory for leadtime
Pos A, consult
factory for leadtime
20, 40, 85
20, 40, 85
10, 20, 40
10,20,40
05,10,20
10,20, 40
05,10
10
Electric Adapters-MSS
(MX)
(L120)
(SMB)
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
PTA-250
PTA-250/6
PTA-250/18
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
7.00
178
1-3/4
1-3/4 x 1-1/2
45 x 25
3.25
82
Ratio
64:1
384:1
1152:1
Efficiency
0.36
0.33
0.31
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
36,000
48,816
32,400
43,934
28,800
(Ft.-Lbs.)
(NM)
25,200
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
Weight
(Lbs)
(Kg)
39,053
34,171
2,604
3,531
473
641
168
227
30,000
40,680
600
273
670
305
(MSS)
FA35
(ISO)
F35
(MSS)
(ISO)
FA30, FA40
F30, F40
670
305
Pos B
Pos A
Pos B
Pos A
Pos B
Pos A
10, 20, 40
20, 40
05, 10
10, 20, 40
Electric Adapters-MSS
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
7.5
190
1-3/4
1-3/4 x 1-1/2
45 x 25
3.93
100
7.75" - 1.75" sq key --- 55,000 ft lbs
8.00" - 2" sq key --- 48,000 ft lbs
8.25" - 2" sq key --- 43,000 ft lbs
8.50" - 2" sq key --- 38,000 ft lbs
8.75" - 2" sq key --- 29,000 ft lbs
Ratio
137:1
272:1
678:1
1344:1
Efficiency
0.35
0.35
0.34
0.34
434
589
218
297
1,430
650
1,430
650
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
61,000
82,768
54,900
74,444
48,800
(Ft.-Lbs.)
(NM)
42,700
57,901
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
2,085
2,829
(Lbs)
(Kg)
1,400
636
Weight
66,173
1,050
1,425
61,000
82,768
1,400
636
(MSS)
FA40
(ISO)
F40
(MSS)
(ISO)
FA35, FA48
F35, F48
Pos A
Pos A
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
85, 140
190
40, 85
40, 85, 190
20,40
20,40
20
20, 40
Electric Adapters-MSS
(MX)
(L120)
(SMB)
* - No longer available
Chart - R23801-001
Flowserve
Limitorque Actuators
PTA
PTA-1000/6
PTA-1000/24
Stem Capacity
Max. Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
9.00
229
2
2 x 1-1/2
50 x 28
5.25
133
9.25" - 2.5" sq key --- 125,000 ft lbs
9.50" - 2.5" sq key --- 110,000 ft lbs
9.75" - 2.5" sq key --- 100,000 ft lbs
10.00" - 2.5" sq key --- 88,000 ft lbs
10.50" - 2.5" sq key --- 70,000 ft lbs
Ratio
348:1
1392:1
Efficiency
0.34
0.34
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
135,000
183,060
121,500
164,754
108,000
146,448
(Ft.-Lbs.)
(NM)
Manual Operation
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
1,741
2,360
(Lbs)
(Kg)
2,625
1,193
Weight
94,500
128,142
463
627
100,000
135,600
2,600
1,182
(MSS)
FA48
(ISO)
F48
(MSS)
(ISO)
FA40
F40
Pos A
Pos B
Pos B
Pos A
20, 40
20, 40, 85
Electric Adapters-MSS
(MX)
(L120)
(SMB)
* - No longer available
Chart - R23801-001
Flowserve
PTC-12
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
PTC
(inches)
1.25
(mm)
32
(inches)
5/16
(mm)
8
(inches) 5/16 x 1/4
(mm)
10 x 8
(inches)
0.625
(mm)
16
1.75
2.5
44
7/16
63.5
5/8
10
1/2 x 3/8
16
5/8 x 7/16
12 x 8
0.75
18 x 11
0.75
19
19
Ratio
42:1
60:1
210:1
60:1
210:1
Efficiency
0.27
0.27
0.24
0.27
0.24
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
880
1600
1600
1193
2170
2170
(Ft -Lbs)
(NM)
150
195
62
195
62
203
264
84
264
84
(Lbs)
(Kg)
27
13
38
17
50
23
38
17
50
23
Weight
(MSS)
(ISO)
(MSS)
(ISO)
FA12
F12
FA14
F14
FA14
F14
FA12, FA16
FA12, FA16
FA12, FA16
FA12, FA16
F12, F16
F12, F16
F12, F16
F12, F16
Pos A
Pos A
Pos A
N/A
N/A
N/A
Electric Adapters-MSS
05
(MX)
(L120)
(SMB)
05, 10
10
05
05, 10
05
10
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
2.625
3.3
65
5/8
86
3/4
3/4 x 1/2
7/8 X 5/8
18 X 11
none (solid nut)
25 X 14
Ratio
68:1
238:1
68:1
238:1
Efficiency
0.30
0.27
0.30
0.27
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
3,000
3,000
4,068
4,068
(Ft -Lbs)
(NM)
338
107
338
107
458
145
458
145
(Lbs)
(Kg)
74
34
86
40
74
34
86
40
Weight
(MSS)
(ISO)
FA16
F16
FA16
F16
(MSS)
(ISO)
FA14
FA14
F14
F14
Pos A
Pos A
N/A
N/A
Electric Adapters-MSS
05
05, 10, 20
05
10
10, 20
10
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
PTC-32** PTC-32/3.5**
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
3.00
75
5/8
7/8 x 5/8
20 x 12
7/8
22
Ratio
65:1
227.5:1
Efficiency
0.29
0.26
Torque ratings
On/Off Torque
(Ft.-Lbs.)
(NM)
3,200
4,339
(Ft -Lbs)
(NM)
338
110
257
149
(Lbs)
(Kg)
61
28
98
45
Weight
(MSS)
(ISO)
FA16
F16
(MSS)
(ISO)
FA14
F14
Pos B
Pos A
Pos A
Pos B
Electric Adapters-MSS
05
10
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
2.95
3.6
75
1/2
92
5/8
5/8 X 7/16
3/4 x 1/2
20 X 12
none (solid nut)
25 X 14
Ratio
88:1
308:1
88:1
308:1
Efficiency
0.30
0.27
0.30
0.27
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
4,000
4,000
5,424
5,424
(Ft -Lbs)
(NM)
338
107
338
107
458
145
458
145
(Lbs)
(Kg)
107
49
119
55
107
49
119
55
Weight
(MSS)
(ISO)
FA16
F16
FA16
F16
(MSS)
(ISO)
FA-25
FA-25
F25
F25
Pos A
Pos A
N/A
N/A
Electric Adapters-MSS
05
05, 10, 20
05
10
10, 20
10
** - No longer available
Chart - R23801-002
Flowserve
PTC-50/2
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
PTC
(inches)
2.95
(mm)
75
(inches)
1/2
(mm)
(inches) 5/8 X 7/16
(mm)
20 X 12
(inches) none (solid nut)
(mm) none (solid nut)
PTC-50/1
PTC-60
PTC-60/3.1 PTC-60/6.6
3.6
4.0
92
5/8
110
7/8
3/4 x 1/2
1 x 3/4
25 X 14
28 x 16
1
25.4
Ratio
183:1
183:1
60:1
184:1
393:1
Efficiency
0.31
0.31
0.32
0.30
0.30
(Ft.-Lbs.)
(NM)
5,310
5,310
8,800
7,200
7,200
11,930
(Ft -Lbs)
(NM)
206
206
712
248
119
279
279
965
336
161
(Lbs)
(Kg)
98
45
98
45
169
77
186
84
186
84
FA25
F25
FA25
F25
Pos A
Pos A
Pos B
Pos B
Pos B
N/A
N/A
Pos A
Pos A
Pos A
05, 10
05, 10
20, 40, 85
05, 10, 20
05, 10
10
10
20, 40, 85
10, 20
10
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
Weight
(MSS)
(ISO)
(MSS)
(ISO)
FA25
F25
Electric Adapters-MSS
(MX)
(L120)
(SMB)
** - No longer available
Chart - R23801-002
Flowserve
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
PTC
PTC-75/2
PTC-75/1
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
4.0
3.75
4.88
110
7/8
95
1/2
124
3/4
1 x 3/4
3/4 x 1/2
1 x 3/4
28 x 16
7/8
25 X 14
(none)
28 x 16
(none)
22
100
Ratio
Efficiency
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
60
186
378:1
309.1:1
309.1:1
0.30
0.28
0.28
0.29
0.29
8,000
9,625
9,625
10,848
13,051
13,051
(Ft.-Lbs.)
(NM)
(Ft -Lbs)
(NM)
722
249
122
215
215
978
336
165
291
291
(Lbs)
(Kg)
166
76
203
93
203
93
185
84
185
84
FA30
F30
FA30
F30
FA25
FA25
F25
F25
Weight
(MSS)
(ISO)
(MSS)
(ISO)
FA25
F25
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
Pos A
N/A
N/A
05, 10, 20
05, 10
05, 10
05, 10
10, 20
10
10
10
Electric Adapters-MSS
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
5.5
140
1-1/4
1-1/4 x 7/8
36 x 20
1.25
32
Ratio
60:1
186:1
378:1
648:1
Efficiency
0.24
0.22
0.22
0.22
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft -Lbs)
(NM)
Weight
(Lbs)
(Kg)
12,000
16,270
1,913
518
283
161
844
303
149
87
275
124
312
142
312
142
312
142
(MSS)
(ISO)
FA30
F30
(MSS)
(ISO)
FA35
F35
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
10, 20, 40
05,10,20
05,10
10,20,40
10,20, 40
10
Electric Adapters-MSS
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
5.5
140
1-1/4
1-1/4 x 7/8
36 x 20
1.25
32
Ratio
60:1
186:1
378:1
648:1
Efficiency
0.24
0.22
0.22
0.22
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft -Lbs)
(NM)
Weight
(Lbs)
(Kg)
15,000
20,338
1,913
518
283
161
844
303
149
87
275
124
312
142
312
142
312
142
(MSS)
(ISO)
FA35
F35
(MSS)
(ISO)
FA30
F30
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
Pos A
Pos A
10, 20, 40
05,10,20
05,10
10, 20,40
10,20,40
10
Electric Adapters-MSS
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
PTC-250
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
PTC-250/6
PTC-250/18
7.00
178
1-3/4
1-3/4 x 1-1/2
45 x 25
3.25
82
Ratio
64:1
384:1
1152:1
Efficiency
0.36
0.33
0.31
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft -Lbs)
(NM)
Weight
(Lbs)
(Kg)
36,000
48,816
2,604
473
168
3,531
641
227
600
273
670
305
670
305
(MSS)
(ISO)
FA35
F35
(MSS)
(ISO)
FA30, FA40
F30, F40
Pos B
Pos A
Pos B
Pos A
Pos B
Pos A
Electric Adapters-MSS
10, 20, 40
05, 10
20, 40
10, 20, 40
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
7.5
190
1-3/4
1-3/4 x 1-1/2
45 x 25
3.93
100
7.75" - 1.75" sq key --- 55,000 ft lbs
8.00" - 2" sq key --- 48,000 ft lbs
8.25" - 2" sq key --- 43,000 ft lbs
8.50" - 2" sq key --- 38,000 ft lbs
8.75" - 2" sq key --- 29,000 ft lbs
Ratio
137:1
272:1
678:1
1344:1
Efficiency
0.35
0.35
0.34
0.34
Torque ratings
On/Off Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
61,000
82,768
(Ft -Lbs)
(NM)
2,085
1,050
434
218
2,829
1,425
589
297
(Lbs)
(Kg)
1,400
636
1,400
636
1,430
650
1,430
650
Weight
(MSS)
(ISO)
FA40
F40
(MSS)
(ISO)
FA35, FA48
F35, F48
Pos A
Pos A
Pos B
Pos B
Pos B
Pos B
Pos A
Pos A
85, 140
40, 85
20,40
20
190
20,40
20, 40
Electric Adapters-MSS
(MX)
(L120)
(SMB)
** - No longer available
Chart - R23801-002
Flowserve
Limitorque Actuators
PTC
PTC-1000/6
Stem Capacity
Max. Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
PTC-1000/24
9.00
229
2
2 x 1-1/2
50 x 28
5.25
133
9.25" - 2.5" sq key --- 125,000 ft lbs
9.50" - 2.5" sq key --- 110,000 ft lbs
9.75" - 2.5" sq key --- 100,000 ft lbs
10.00" - 2.5" sq key --- 88,000 ft lbs
10.50" - 2.5" sq key --- 70,000 ft lbs
Ratio
348:1
1392:1
Efficiency
0.34
0.34
Torque ratings
On/Off Torque
(Ft.-Lbs.)
(NM)
135,000
183,060
(Ft -Lbs)
(NM)
1,741
463
2,360
627
(Lbs)
(Kg)
2,625
1,193
2,600
1,182
Weight
(MSS)
(ISO)
FA48
F48
(MSS)
(ISO)
FA40
F40
Pos A
Pos B
Pos B
Pos A
Electric Adapters-MSS
(MX)
(L120)
(SMB)
20, 40
20, 40, 85
** - No longer available
Chart - R23801-002
Flowserve
PTD-250
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
PTD
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
PTD-250/6
PTD-250/18
7.00
178
1-3/4
1-3/4 x 1-1/2
45 x 25
3.25
82
Ratio
64:1
384:1
1152:1
Efficiency
0.36
0.33
0.31
Torque ratings
Start Torque
Dynamic Torque
Max. One Time Input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft -Lbs)
(NM)
Weight
(Lbs)
(Kg)
36,000
48,816
12,600
17,086
2,604
3,531
473
641
168
227
600
273
670
305
670
305
(MSS)
(ISO)
FA35
F35
(MSS)
(ISO)
FA30, FA40
F30, F40
Pos B
Pos A
Pos B
Pos A
Pos B
Pos A
85, 140,150
85, 190
0, 1, 2
10, 20, 40
10, 20, 40
00
05, 10
10, 20, 40
00
Electric Adapters-MSS
Chart - R23801-003
(MX)
(L120)
(SMB)
Flowserve
PTD-500
Stem Capacity
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
PTD
PTD-500/2.15
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
PTD-500/4.25
PTD-500/10.6
PTD-500/20.9
7.5
190
1-3/4
1-3/4 x 1-1/2
45 x 25
3.93
100
7.75" - 1.75" sq key --- 55,000 ft lbs
8.00" - 2" sq key --- 48,000 ft lbs
8.25" - 2" sq key --- 43,000 ft lbs
8.50" - 2" sq key --- 38,000 ft lbs
8.75" - 2" sq key --- 29,000 ft lbs
Ratio
64:1
137:1
272:1
678:1
1344:1
Efficiency
0.36
0.35
0.35
0.34
0.34
Torque ratings
Start Torque
Dynamic Torque
Max. One Time Input
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
61,000
82,768
21,350
28,969
(Ft -Lbs)
(NM)
4,034
5,474
2,085
2,829
1,050
1,425
434
589
218
297
(Lbs)
(Kg)
1,000
454
1,400
636
1,400
636
1,400
636
1,400
636
(MSS)
(ISO)
FA40
F40
FA40
F40
FA40
F40
FA40
F40
FA40
F40
(MSS)
(ISO)
Weight
FA35, FA48
F35, F48
Pos B
Pos A
Pos A
Pos B
Pos B
Pos A
Pos B
Pos B
Pos A
Pos A
85, 140
190
0, 1, 2
40, 85
40, 85, 190
00, 0, 1, 2
20,40
20,40
00
20
20, 40
00
Electric Adapters-MSS
Chart - R23801-003
Flowserve
WG-04-B
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
WGB
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
WG-04-1S-B WG-04-1SD-B
WG-05-B
WG-05-1S-B WG-05-1SD-B
3.688
95
4.5
115
7/8 x 7/8
-
1x1
-
7/8 x 5/8
25x14
1 x 3/4
32x18
Ratio
56:1
168:1
504:1
60:1
180:1
540:1
Efficiency
.31
.27
.24
.32
0.27
0.24
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
7670
10399
11720
15890
6903
9359
6136
10548
14300
9376
8319
12711
(Ft.-Lbs.)
(NM)
5369
8204
7279
11122
(Ft.-Lbs.)
660
252
96
942
360
138
(Lbs)
(Kg)
124
155
177
194
225
247
56
70
80
88
102
112
Weight
(MSS)
(ISO)
FA25
FA25/FA30
F25
F25/F30
(MSS)
(ISO)
FA16
F16
-------
Pos A
Pos A
Pos A
Pos A
Pos A
Pos A
Pos D
Pos D
Pos D
Pos D
Pos D
Pos D
Electric Adapters-MSS
20, 40
20, 40
05, 10, 20
10, 20
05
10
20, 40
20, 40
05, 10, 20
10, 20
05,10
10,20
Chart - R23801-001
(MX)
(L120)
Flowserve
WG-55-B
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
WGB
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
4.875
125
1 1/4 x 1 1/4
1 1/4 x 7/8
32x18
Ratio
62:1
186:1
372:1
558:1
Efficiency
.32
.28
0.24
.24
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
17330
23497
(Ft.-Lbs.)
(NM)
12131
(Ft.-Lbs.)
(Lbs)
(Kg)
Weight
15597
21146
13864
18796
16447
1,318
504
289
193
276
319
347
347
125
145
157
157
(MSS)
(ISO)
FA25/FA30
(MSS)
(ISO)
FA30/FA35
F30/F35
F25/F30
Pos A
Pos A
Pos A
Pos A
Pos D
Pos D
Pos D
Pos D
20, 40, 85
20, 40, 85
10, 20, 40
10,20,40
05, 10, 20
10, 20
05,10
10, 20
Electric Adapters-MSS
Chart - R23801-001
(MX)
(L120)
Flowserve
Limitorque Actuators
WGD
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
WG-05-D
WG-05-1S-D WG-05-1SD-D
3.688
95
4.5
115
7/8 x 7/8
-
1x1
-
7/8 x 5/8
25x14
1 x 3/4
32x18
Ratio
56:1
168:1
504:1
60:1
180:1
540:1
Efficiency
.31
.27
.24
.32
0.27
0.24
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
7,670
10399
11720
15890
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
660
252
96
942
360
138
(Lbs)
124
155
177
194
225
247
(Kg)
56
70
80
88
102
112
Weight
(MSS)
(ISO)
FA25
F25
FA25/FA30
F25/F30
(MSS)
(ISO)
FA16
F16
-------
Pos A
Pos A
Pos A
Pos A
Pos A
Pos A
Pos D
Pos D
Pos D
Pos D
Pos D
Pos D
Electric Adapters-MSS
20, 40
20, 40
05, 10, 20
10, 20
05
10
20, 40
20, 40
05, 10, 20
10, 20
05,10
10,20
Chart - R23801-001
(MX)
(L120)
Flowserve
WG-55-D
Max. Bore:
Max Square Key:
Max Rectangular Key:
Minimum Bore:
Limitorque Actuators
WGD
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
(inches)
(mm)
4.875
125
1 1/4 x 1 1/4
1 1/4 x 7/8
32x18
Ratio
62:1
186:1
372:1
558:1
Efficiency
.32
.28
0.24
.24
Torque ratings
On/Off Torque
Modulating - 100 Starts/Hr
Modulating - 600 Starts/Hr
Modulating - Continuous
Max one time input
(motor operation only)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
(NM)
17330
23497
(Ft.-Lbs.)
(NM)
(Ft.-Lbs.)
Weight
1,318
504
289
193
(Lbs)
276
319
347
347
(Kg)
125
145
157
157
(MSS)
(ISO)
FA25/FA30
F25/F30
(MSS)
(ISO)
FA30/FA35
F30/F35
Pos A
Pos A
Pos A
Pos A
Pos D
Pos D
Pos D
Pos D
20, 40, 85
20, 40, 85
10, 20, 40
10,20,40
05, 10, 20
10, 20
05,10
10, 20
Electric Adapters-MSS
Chart - R23801-001
(MX)
(L120)
Multi-turn actuators
and gearboxes
mounting base comparison
Flowserve
Unit Size
FA (MSS) F (ISO)
STD (Standard)
OPT (Optional)
Base
MX-05
MX-10
MX-20
MX-40
MX-85
MX-140
MX-85
FA10
FA10
FA14
FA14
FA16
FA25
FA25
F10
F10
F14
F14
F16
F25
F25
STD
STD
STD
STD
STD
STD
OPT
L120-10
L120-20
L120-40
L120-80
L120-85
L120-190
L120-420
L120-420
L120-800
L120-800
L120-2000
L120-2000
FA10
FA14
FA14
FA16
FA16
FA30
F10
F14
F14
F16
F16
F30
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
SMA-000
SMA-00
SMA-0
SMA-1
SMA-2
SMA-3
SMA-4
SMA-5
SMB-000
SMB-00
SMB-0
SMB-1
SMB-2
SMB-3
SMB-4
SMB-5
SMB-5T
SMC-04
SMC-03
SMC-031
SMC-041
SMC-00
SMC-0
SMC-1
SMC-2
SMC-3
SMC-4
SMC-4T
SMC-5
Chart R400-001
F35
FA40
FA14
FA16
FA25
FA30
FA40
FA14
FA16
FA25
FA30
FA40
FA10
FA10
FA10
FA14
FA16
FA25
FA30
FA40
Limitorque Actuators
Comments
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
Multi-turn actuators
and gearboxes
mounting base comparison
Flowserve
Unit Size
FA (MSS) F (ISO)
SM-00
SM-0
SM-1
SM-2
SM-3
SM-4
SM-5
SB-000
SB-00
SB-0
SB-1
SB-2
SB-3
SB-4
SBD-00
SBD-0
SBD-1
SBD-2
SBD-3
SBD-4
LMC-04
LMC-041
LMC-03
LMC-031
LMC-00
LMC-3
FA14
FA16
FA25
FA30
STD
STD
STD
STD
STD
STD
STD
FA14
FA16
FA25
FA30
FA40
FA14
FA16
FA25
FA30
STD
STD
STD
STD
STD
STD
FA40
STD
STD
STD
STD
STD
STD
FA10
FA10
FA14
FA10
FA14
FA16
FA10
FA10
FA14
LNC-000
LNC-00
LNC-0
FA10
FA14
FA16
B-20
B-30
B-35
B-40
B-50
B-60
FA14
FA16
FA25
FA25
FA30
B320-05
B320-10
B320-20
B320-30
B320-40
B320-50
FA10
FA14
FA14
FA14
FA16
FA25
Chart R400-001
STD
STD
STD
STD
STD
STD
STD
FA40
LNC-000
LNC-00
LNC-0
LMC-03
LMC-031
LMC-00
LMC-3
STD (Standard)
OPT (Optional)
Base
STD
STD
STD
STD
STD
STD
STD
Limitorque Actuators
Comments
STD
STD
STD
F14
F16
F25
F25
F30
STD
STD
STD
STD
STD
Same as FA35 but has Non-standard bolt size 8 holes 1 1/4x7
F10
F10
F14
F14
F16
F25
STD
STD
STD
STD
STD
STD
Multi-turn actuators
and gearboxes
mounting base comparison
Flowserve
Unit Size
FA (MSS) F (ISO)
B320-60
B320-70
FA30
FA30
STD (Standard)
OPT (Optional)
Base
F30
B320-80
B320-80
B320-90
B320-90
B320-100
B320-100
F35
STD
STD
Manufactured by Mastergear
Manufactured by Mastergear
FA40
FA40
MT-2
MT-3
MT-4
FA16
FA25
FA30
STD
STD
STD
VB-3
VB-9.5
VB-21
VB-120
FA14
FA16
FA25
FA40
STD
STD
STD
STD
VBT-3/2.5
VBT-3/5
VBT-21/8
VBT-9.5/5
VBT-9.5/8
VBT-21/12
VBT-80/20
VBT-120/3
VBT-120/4
FA14
FA16
FA25
FA25
FA25
FA30
STD
STD
STD
STD
STD
STD
STD
STD
STD
B-3H
B-3H
FA40
STD
STD
STD
STD
STD
STD
STD
STD
FA25
FA30
FA16
F16
STD
STD
STD
STD
STD
A110
A111
HOBC
H1BC
H2BC
H3BC
H4BC
H5BC
H6BC
H7BC
F40
F40
Comments
STD
STD
STD
FA40
Limitorque Actuators
STD
STD
Notes:
1) This information is for reference only. When repacing existing actautors, always refer to the applicable bill of material to
confirm exact base of existing actuator
2) Base types listed above as standard will be provided unless the optional base is specified.
3) These are the 360 degree gear HBC units
Chart R400-001
Flowserve
Unit Size
FA
F
(MSS) (ISO)
STD (Standard)
OPT (Optional)
Base
LY-1001
LY-2001
LY-3001
FA10
FA14
FA14
F10
F14
F14
STD
STD
STD
QX-1
QX-1
QX-1
QX-2
QX-2
QX-3
QX-3
QX-3
QX-4
QX-4
QX-5
QX-5
FA10
FA05
FA07
FA10
FA07
FA12
FA10
FA14
FA14
FA12
FA14
FA12
F10
F05
F07
F10
F07
F12
F10
FA14
FA14
F12
FA14
F12
STD
OPT
OPT
STD
OPT
STD
OPT
OPT
STD
OPT
STD
OPT
PB2A
FA14
T-050
T-100
T-140
T-150
T-160
T-200
T-250
T-300
T-325
T-350
T-400
T-425
T-430
T-450
T-500
T-550
T-575
T-600
T-650
T-700
T-750
FA10
FA12
FA12
FA12
FA12
FA14
FA16
FA16
FA25
FA25
FA30
FA30
FA35
FA35
FA40
FA48
FA48
FA48
FA48
WTRC-3
WTRC-5
WTRA-6
WTRC-10
WTRA-12
WTRC-15
WTRA-21
WTRA-36
WTRC-40
WTRC-40
WTRA-48
WTRA-48
WTRC-60
WTRA-72
WTRA-130
WTRC-150
WTRA/C-430
WTRA/C-450
WTRA/C-500
WTRA/C-575
Chart R400-002
FA10
FA10
FA10
FA12
FA10
FA14
FA16
FA19
Comments
Reduced torque
STD
F10
F12
F12
F12
F12
F14
F16
F16
F25
F25
F30
F30
F35
F35
F40
F48
F48
F48
F48
F07
F10
F14
F14
F16
F16
FA19
FA25
FA25
FA30
FA30
FA35
FA35
FA40
FA48
Limitorque
F16
F25
F25
F30
F30
F35
F35
F40
F48
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
Flowserve
Unit Size
FA
F
(MSS) (ISO)
VGC-3
VGC-8
VGC-20
STD (Standard)
OPT (Optional)
Base
STD
STD
STD
PTA10
PTA/C-12
PT-18
PTA/C-14
PTA/C-14
PTA/C-14
PTA/C-18
PTA/C-30
PTA/C-30
PTA/C-32
PTA/C-40
PTA/C-40
PTA/C-50
PTA/C-60
PTA/C-65
PTA/C-65
PTC-75
PTC-75
PTA/C-120
PTA/C-150
PTA/C-250
PTA/C-120
PTA/C-150
PTA/C-250
PTA/C-500
PTA/C-250
PTA/C-500
PTA/C-500
PTA/C-1000
PTA/C-1000
FA12
FA12
FA12
FA14
FA12
FA16
FA14
FA16
FA14
FA16
FA16
FA25
FA25
FA25
FA25
FA16
FA30
FA25
FA30
FA30
FA30
FA35
FA35
FA35
FA35
FA40
FA40
FA48
FA48
FA40
HOBC
H1BC
H2BC
FA25
FA30
F12
F12
F12
F14
F12
F16
F14
F16
F14
F16
F16
F25
F25
F25
F25
F16
F30
F25
F30
F30
F30
F35
F35
F35
F35
F40
F40
F48
F48
F40
Limitorque
Comments
STD
STD
OPT
STD
OPT
OPT
STD
STD
OPT
STD
STD
OPT
STD
STD
STD
OPT
STD
OPT
STD
OPT
OPT
OPT
STD
STD
OPT
OPT
STD
OPT
STD
OPT
STD
STD
STD
H3BC
STD
H4BC
STD
H5BC
H6BC
H7BC
STD
STD
STD
Notes:
1) This information is for reference only. When repacing existing actautors, always refer to the applicable
bill of material to confirm exact base of existing actuator
2) Base types listed above as standard will be provided unless the optional base is specified.
Chart R400-002
Flowserve
Limitorque
FA (MSS)
Mountin
g
Base
FA07
FA10
FA14
FA16
FA25
FA30
FA35
FA40
FA48
F (ISO)
No. of Bolt
Bolt
Registe
Bolts Size (d4) Circle (d3) r (d2)
Mounting No. of
Base
Bolts
Bolt
Bolt
Register
Size (d4) Circle (d3) (d2)
4
4
4
4
8
8
8
8
12
F07
F10
F14
F16
F25
F30
F35
F40
F48
M8
M10
M16
M20
M16
M20
M30
M36
M36
Chart R400-003
5/16-18
3/8-16
5/8-11
3/4-10
5/8-11
3/4-10
1-8
1 1/4-7
1 1/4-7
2.75
4.00
5.50
6.50
10.00
11.75
14.00
16.00
19.00
2.166
2.312
3.750
5.000
6.000
7.000
8.500
9.000
4
4
4
4
8
8
8
8
12
70
102
140
165
254
298
356
406
483
55
70
100
130
200
230
260
300
370
Flowserve
Chart 400-004
Limitorque