shall be constructed entirely of incombustible materials concrete not less than 200 millimeters
when more than 7.50 meters in height, and shall be directly
thick, Except, that stone masonry
supported on an incombustible framework to the ground.
shall
No be not less than 300 millimeters
such skeleton towers shall be supported on roofs of
thick and, in addition shall be lined
combustible framings. They shall be designed to withstand
withanot less than 100 millimeters of
wind load from any direction in addition to any other
firebrick laid in a solid bed of fire
loads.
clay mortar with solidly filled head,
Section 1211. Chimneys, Fireplaces, and Barbecues.
bed, and wall joints, starting not
(a) Chimneys
less than 600 millimeters below the
(1) Structural Design
chimney connector entrance. Chimneys
Chimneys shall be designed, anchored, supported,
extending 7.50 meters or less above
reinforced, constructed, and installed in
the chimney connector shall be lined
accordance with generally accepted principles of
to the top.
engineering. Every chimney shall be capable of
(2.4) Masonry Chimneys for High-Heat
producing a draft at the appliance not less than
Appliances
that required for the safe operation of the
Masonry chimneys for high-heat
appliance connected thereto. No Chimney shall
appliances shall be constructed with
support any structural load other than its own
double walls of solid masonry units or
weight unless it is designed to act as a
reinforced concrete not less than 200
supporting member. Chimneys in a wood-framed
millimeters in thickness, with anr
building shall be anchored laterally at the
space of not less than 50 millimeters
ceiling line and at each floor line which is more
between walls. The inside of the
than 1.80 meters above grade, except when
interior walls shall be of fire-brick
entirely within the framework or when designed to
not less than 100 millimeters in
be free standing.
thickness laid in a solid bed of fire
__________________________________________________________________
clay mortar with solidly filled head,
________
bed, and wall joints.
Anotated PRESIDENTIAL DECREE (P.D.) NO. 1096
__________________________________________________________________
(The 1977 National Building Code of the Philippines/ NBCP)
________
45 of 81
Anotated PRESIDENTIAL DECREE (P.D.) NO. 1096
(2) Walls
(The 1977 National Building Code of the Philippines/ NBCP) page
Every masonry chimney shall have walls of masonry
46 of 81
units, bricks, stones, listed masonry chimney
(2.5) Masonry Chimneys for Incinerators
units, reinforced concrete or equivalent solid
Installed in Multi-Storey Buildings
thickness of hollow masonry and lined with
(Apartment-Type Incinerators)
suitable liners in accordance with the following
Chimneys for incinerators installed in
requirements:
multi-storey building using the
(2.1) Masonry Chimneys for Residential Type
chimney passageway as a refuse chute
Appliances
where the horizontal grate area of
Masonry chimneys shall be constructed
combustion chamber does not exceed
of masonry units or reinforced
0.80 square meter shall have walls of
concrete with walls not less than 100
solid masonry or reinforced concrete,
millimeters thick; or of rubble stone
not less than 100 millimeters thick
masonry not less than 300 millimeters
with a chimney lining as specified in
thick. The chimney liner shall be in
this Code. If the grate area of such
accordance with this Code.
an incinerator exceeds 0.80 square
(2.2) Masonry Chimneys for Low Heat
meter, the walls shall not be less
Appliances
than 100 millimeters of firebrick
Masonry chimneys shall be constructed
except that higher than 9.00 meters
of masonry units or reinforced
above the roof of the combustion
concrete with walls not less than 200
chamber, common brick alone 200
millimeters thick: Except, that rubble
millimeters in thickness, may be used.
stone masonry shall be not less than
(2.6) Masonry Chimneys for Commercial and
300 millimeters thick. The chimney
Industrial Type Incinerators Masonry
liner shall be in accordance with this
chimneys for commercial and industrial
Code.
type incinerators of a size designed
(2.3) Masonry Chimneys for Medium-Heat
for not more than 110 kilograms of
Appliances
refuse per hour and having a
Masonry chimneys for medium-heat
horizontal grate area not exceeding
appliances shall be constructed of
0.50 square meter shall have walls of
solid masonry units of reinforced
solid masonry or reinforced concrete