Sei sulla pagina 1di 9

SW0D5-ALVLS-EUL license CD-ROM

2008/March

The following items have been either amended or added to the VLS software package:
2.50 -> 2.60 Updated items
1.Support for Windows Vista.
2. The following bugs were fixed:
1) The error that when a Time Switch FB is imported into the software. All versions corrected other than the
English version as no bug occurs here.
2007/January

2.40 -> 2.50 Updated items


1.Support of AL2 controller version 3.
1.1. The setup of Menu language for AL2 controller is added.
1.2. The setup of Menu call key is added.
1.3. Support Russian characters.
Display function
SMR function
2005/June

2.33 -> 2.40 Updated items


1. Support for AL2-10MR controller.

2.The following function item have been added:


SMR function
CD function
3. Import and export functions for the time switch setting have been added.
4.A summertime setting based on Sunday has been added.
5. The following 2 protection functions have been added.
1) Program read protection
2) Copy program to memory cassette protection

6. The function to add quotation mark to PINCODE has been added to the GSM setting.
7. The FB number replace function has been added.
8. Russian language support has been added.
2004/April

2.32 -> 2.33 Updated items


1. The help contents were revised.
2. The following bugs were fixed:
1) The AND/NOT logic operation within a UserFunc block was incorrect when the output sub-wire was
connected to the same UserFunc block input.
2) After program save, connection wire positions were different to the original location.
3) Communication error occurred during monitoring of the program in which the time switch FB was
included.
2003/December

2.31 -> 2.32 Bug content


Software other than English version had some incorrect translation.
2003/September

2.30 -> 2.31 Bug content


When UseFunc registered had 100 or more wires., this UserFunc was not able to be placed
2003/July

2.20 -> 2.30: Updated items

1. Support of AL2 controller version 2.


1.1 The input icons are added.
Analog input (PT100)
Analog input (TC)
DCF77 flags (M10, M11, M15)
Sensor error flag (M17 to M24)
2DA Power Supply flag (M16)
1.2 The function icons are added.
Analog Output function
PID function
1.3 The setup of Radio Clock (DCF77) is added.
1.4 The temperature scale setup of the analog input is added.
2003/February

2.13 -> 2.20


1) A UserFunc block embedded with a UserFunc block can be registered if the project was created using a
different Personal Computer.
2) The main and sub wires connected to a UserFunc block moved from its original location during a
simulation of the user program.
3) The sub wires connected to an empty UserFunc block disappeared during a simulation of the user
program.
4) An application error occurred if a UserFunc block that had a sub wire connected to an input is copied
and pasted onto the Function Block Diagram (FBD).
5) The Display Function block parameters changed during a simulation of the user program due to a
separate UserFunc block located on the FBD.
6) The Alpha 2 Series Controller does not support space characters, therefore, such characters entered into
a Display function block string will cause an error with the verification function.
7) After simulating the user program, forbidden UserFunc block analog word output pin wiring was
permitted.
8) Under certain circumstances, an application error occurred because the Alpha 2 project settings were
changed to Alpha project settings with a Display Function block located on the FBD.
9) Modification to the number of UserFunc block input/output pins did not always guarantee a successful
change.
10) The deletion of a UserFunc block failed to update the memory usage allocation settings held in the VLS
software.
11) The monitoring items, which are placed under each function block during a simulation of the user
project, failed to appear on the SubFBD when the user scrolled to the bottom of the screen.
12) An application error occurred due to the deletion of a comment from the SubFBD.
13) The parameter information for connected function blocks was not updated when an nsert funcusing
the right click of the mouse was performed on the connecting main wire.
14) The CTRL+Z shortcut key that clears a mistaken operation did not clear a copy and paste procedure.
15) The following operation caused an application error:
16) Select two Function Blocks on the FBD (ex. One Shot and the Up/Down Counter)
17) Connect the two function blocks using their respective word pins
18) Select all and the paste the contents to the Monitoring in System Sketch window.
19) While simulating the user project open the One Shot dialog box.
20) Directly connecting the word input pin to the word output pin of an UserFunc block will prevent an
update of the function block attached to the word output pin.
21) Function blocks held inside a UserFunc were not accessible using the Alpha 2 Series Controller
Computer Link Function.
2.10 -> 2.13 Bug content
1) Parameter information of function blocks held inside a UserFunc block changed after the simulation
of the user project was completed.
2) Shutting down VLS that contained a user project with numerous amounts of UserFunc blocks caused
an application error.
3) Deletion of the UserFunc causes an application error.

4) Simulating the Shift Function Block appears to differ form the actual perceived shift-bit operation.

2.10 -> 2.11 Bug content.


1. When a numerical value was set using the spin buttons within the function block dialog box and then
confirmed with the OK button, if the window was then reopened a different value appeared as the setting for
the function block.
1) Open the setting dialog box of Function Block.
2) Data is set. (Example: Data is 300)

3) Press the [OK] button.


4) Reopen the same setting dialog box.
5) Set data is set to zero.

2.00 -> 2.10 Updated items.


1. Windows XP (home or professional versions) supported.
2. The setup of COM port was enabled to COM10.
3. The function block editing dialog windows now contain easy to use spin buttons.
4. Import/Export feature added for the UserFunc Block.

This CD contains the following:


\Installer
|
|--- \LicenseVersion
|
|--- \DemoVersion
|

(Installer files of official version. Copy the all files to CD-ROM.)


(Installer files of demonstration version. You can provide it by free.)

\Bin_Data
(Binary data files.)
|
|--- \Avi
(AVI Data files.)
|
|
|
|--- Adata.bin
|
|--- Alt.avi
|
|--- Compare.avi
|
|--- Continue.avi
|
|--- Continue2.avi
|
|--- Counter.avi
|
|--- Delay.avi
|
|--- Flicker.avi
|
|--- Lamp.avi
|
|--- OneShot.avi
|
|--- Pulse.avi
|
|--- SetReset.avi
|
|--- Tgl.avi
|
|--- \Program
(Program Data files.)
|
|
|
|--- Common
|
|
|
|
|
|--- CodeGen.dll
|
|
|--- modem.ini
|
|
|--- GSM.ini
|
|
|--- Readme.txt
|
|
|
|--- English
|
|
|
|
|
|--- CommMan.dll
|
|
|--- Vls.cnt
|
|
|--- Vls.exe
|
|
|--- Vls.hlp
|
|
|--- VLSWiz.cnt
|
|
|--- Vlswiz.dll
|
|
|--- Vlswiz.hlp
|
|
|
|--- French
|
|
( The same images as the above <English> folder. )
|
|
|
|--- German
|
|
( The same images as the above <English> folder. )

|
|
|
|--- Italian
|
|
( The same images as the above <English> folder. )
|
|
|
|--- Spanish
|
|
( The same images as the above <English> folder. )
|
|
|
|--- Swedish
|
|
( The same images as the above <English> folder. )
|
|--- \System
(System Data files.)
|
|
|
|--- Common
|
|
|
|
|
|--- mfc42.dll
|
|
|--- mscal.ocx
|
|
|--- Msflxgrd.ocx
|
|
|--- msvcrt.dll
|
|
|--- Oleaut32.dll
|
|
|--- Olepro32.dll
|
|
|--- Stdole2.tlb
|
|
|
\Document
(Document file.)
|
|--- DOC.doc
(This document. Microsoft WORD.)

Attention concerning installer creation.


The in-Datawill be useful for you to make the installer by yourselves. When you make your special
installer, your installer should copy the files using the following:
\Your or customer favorite folder name
\Bin
(Fixed folder name.)
\Avi
(Fixed folder name.)
Adata.bin
Alt.avi
Compare.avi
Continue.avi
Continue2.avi
Counter.avi
Delay.avi
Flicker.avi
Lamp.avi
OneShot.avi
Pulse.avi
SetReset.avi
Tgl.avi
CodeGen.dll
CommMan.dll
modem.ini
GSM.ini
Vls.cnt
Vls.exe
Vls.hlp
VLSWiz.cnt
VLSWiz.dll
Vlswiz.hlp
\Prog
(Fixed folder name. You may not copy any files in this folder.)
\Rel
(Fixed folder name. You may not copy any files in this folder.)
\Library
\Bitmap
(Fixed folder name. You may not copy any files in this folder. )
\Image
(Fixed folder name. You may not copy any files in this folder. )
\UserFunc
(Fixed folder name. You may not copy any files in this folder. )
Readme.txt
(You can copy this file to your favorite place.)
You are required to copy the below files in the Windows System directory. When you copy these files to the
Windows System, check whether the customer PC has the files already or not. If the customer PC
has contains such files, copying the files is not needed.
For this conditional installing, check the date and version of the each file.
\Windows
\System
mfc42.dll
mscal.ocx
Msflxgrd.ocx
msvcrt.dll
Oleaut32.dll
Olepro32.dll
Stdole2.tlb

And it is better for you to set up the Windows Registry as the followings.
\HKEY_CURRENT_USER
\Software
\Mitsubishi Electric
\Visual Logic Support
\Recent File List
\Settings

(No data is required.)


(No data is required.)

\HKEY_LOCAL_MACHINE
\SOFTWARE
\Mitsubishi Electric
\Visual Logic Support
\App

(No data is required.)

Potrebbero piacerti anche