Sei sulla pagina 1di 7

DT Cable Vaults Sidewalk/Driveway

Product Description
The DT range of thermoplastic Cable Vaults offer superior vertical and lateral load capabilities in sidewalk and
driveway applications. Specifically designed to withstand high static loads and sidewall deflection, the DT vaults are
manufactured from a strong and lightweight HDPE material for ease of handling and designed to perform in harsh
environmental conditions.
The DT Cable Vault is a robust underground access solution for use in telecommunication, electrical, utility and
transport infrastructure deployments where vault integrity is paramount.

Features

Strong and Lightweight Straight Wall Design Superior Static and Sidewall Deflection
Robust - Structural Foam Construction (UV stabilised)
Extension Collar or Base Depth Extensions
Suitable for Cutover applications.
External rib pockets secure and stabilise vault in position when backfilled
Security Lid options - Polymer Concrete (PC) and Steel (ST).
Design Load 22.5k lbs Test Load 50k pounds lbs (22.5 tonne)
- Medium Duty - Grey Body and Grey Polymer Concrete (PC) drop-in or Steel Lid
- Heavy Duty - Grey Body and Grey Polymer Concrete (PC) with PC Collar
Stainless Steel Hardware
Sidewall or Bottom Conduit Entry - Self-Draining
Closed Lifting Holes on PC Lid
Private Logo Option

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

DT1118
External Dimensions (W) 425mm (16) x (L) 603mm (23)
Standard Body Depths 230mm (9), 457mm (18)
Nominal Body Weight: 7kg; PC Lid - 13kg

DT1212
External Dimensions (W) 457mm (18) x (L) 457mm (18)
Standard Body Depths 356mm (14)
Nominal Body Weight 10kg

DT1124 Clear Opening

DT1212 Clear Opening


DT1324
External Dimensions: (W) 466mm (18) x (L) 708mm (27)
Standard Body Depths 381mm (15), 457mm (18), 610mm (24)
Nominal Body Weight 13kg; PC Lid 18kg

DT1324 Clear Opening

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

DT1730
External Dimensions: (W) 560mm (30) x (L) 890mm (35)
Standard body Depth 381mm (15), 610mm (24), 914mm (36)
Nominal Body Weight 17kg; PC Lid 36kg

DT1730 Clear Opening

DT2436
External Dimensions: (W) 762mm (30) x (L) 1041mm (41)
Standard Body Depth 427mm (16), 610mm (24), 914mm (36)
Nominal Body Weight 36kg; PC Lid 52kg solid (26kg split lid)

DT2436 Clear Opening

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

DT3048
External Dimensions: (W) 942mm (37) x (L) 1359mm (53)
Standard Body Depth 914mm (36)
Nominal Body Weight 55kg; PC Lid 92kg solid (46kg split lid)

DT2436 Clear Opening


PC Lid and Collar Hex Lock
Bolt Down (standard)

Rack and Steps (Galvanised)

Racks
381mm (15) long
610 mm (24) long
762mm (30) long
Steps
178mm (7) long
254mm (10) long
356mm (14) long
457mm (18) long
Polymer Concrete
(Medium Duty)

Polymer Concrete
Lid with PC Collar
(Heavy Duty)

HDPE Raising Collar Extension


Standard Body Depth 75mm (3)
Nominal Body Weight 6kg
Available sizes: DT1324-3 and DT1730-3

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

Parts and Configurations

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

Technical Information
Underground Enclosure Technical Performance Specifications
PenCell products are designed and tested for compliance with Western Underground Committee Guide 3.6,
Telcordia GR-902 and GR-13, and ANSI/SCTE 77-2007 which is referenced in the National Electric Code (N.E.C.)
section 314.30 as the requirement for enclosure integrity.
All PenCell products have met the acceptance of the (USDA) United States Dept of Agriculture, (R.U.S.) Rural Utility
Service and are listed with this organization.
To meet the acceptance criteria of these agencies, underground enclosures must successfully pass numerous
material and product performance tests.
Some of these requirements include:
Three position load testing for structural integrity verification.
(Vertical, Vertical Sidewall and Lateral Sidewall loading)
UV Degradation per ASTM G-53
Fire Resistance per RUS7CFR 1755.910 and WUC 3.6 Section 5.2.7
Chemical Resistance per ASTM D-543
Water Absorption per ASTM D-570
Impact Resistance per ASTM D-2444
Accelerated Service per ASTM D-756
Weathering per ASTM D-822
Static Coefficient of Friction (Cover Slip Test) per ASTM C1028-96
Material Information:
High Density Polyethylene (H.D.P.E.) is used in both Structural Foam injection molded and Rotation molded
products. Polymer Concrete is used for lids that are rated to 10,000 (Class B 80kN) and 20,000 lbs. (Class C
150kN) loads. Steel lids are available on some products and are rated up to 10,000 lbs. (Class B -80kN).
Testing on PenCell products is conducted by third party independent testing labs; Under observation of a private
third party licensed P.E. (Professional Engineer) and at Pencells Certified Testing Lab by qualified Engineering and
Quality Assurance personnel, All test results are documented in accordance with our ISO 9001-2008 Quality
Management System standards.
PenCell Products are not intended for use in a direct roadway application.

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

About Polymer Concrete


Polymer concrete is made from selectively-graded aggregates in combination with a polymer resin system.
When combined through a process of mixing, molding and curing, an extremely powerful cross-linked bond is
formed.
Precast polymer concrete is reinforced with fiberglass for exceptional strength and rigidity.

Reasons to Choose Polymer Concrete


1. Lightweight - 1/10 to 1/3 the weight of concrete
2. High Strength - compressive, flexural and tensile strengths three to five times higher than traditional
concrete
3. Reduced Installation Costs - easy to handle, no special equipment required
4. Stable Under Freeze/Thaw Conditions
5. Impact Resistant - tested per ASTM D-2444
6. Low Water Absorption - less than 1% per ASTM D-570
7. Corrosion Resistant - resistant to alkalines, acids, weathering and other forms of deterioration
8. Cost Effective - outperforms conventional materials for longer service and lower life cycle costs
9. Nonflammable - will not support combustion
10. Nonconductive - no grounding required for the box or cover
11. Non Hazardous

Velnah Pty Limited | Sydney, Australia | ph: +61 487 911 361 | sales@velnah.com | www.velnah.com
2012 Velnah Pty Limited. All rights reserved.

Potrebbero piacerti anche