Tekla Structures

Hole Reservation Manager


.

Purpose to coordinate structural design with


building services designers when handling hole
reservations (void provisions)

29.5.2013
Hole Reservation Manager

Process description

29.5.2013
Hole Reservation Manager

Insert IFC files

29.5.2013
Hole Reservation Manager

Open Hole Reservation Manager dialog

29.5.2013
Hole Reservation Manager

Create Tekla Structures hole reservation part

29.5.2013
Hole Reservation Manager

Help view creation to check situation


3D view creates a basic view of selected hole
reservation

29.5.2013
Hole Reservation Manager

Create real cut (hole) to model

29.5.2013
Hole Reservation Manager

Find a right hole reservation in the model/dialog

29.5.2013
Hole Reservation Manager

Management options in dialog

29.5.2013
Hole Reservation Manager

10

Hole reservation GA drawing in Tekla Structures

29.5.2013
Hole Reservation Manager

11

Edit GA drawing

29.5.2013
Hole Reservation Manager

12

Revision handling

29.5.2013
Hole Reservation Manager

13

Update hole reservation parts/real cuts

29.5.2013
Hole Reservation Manager

14

GA drawing will be updated

29.5.2013
Hole Reservation Manager

15

Status accepted but changed

29.5.2013
Hole Reservation Manager

16

Report creation

29.5.2013
Hole Reservation Manager

17

Needed files 1/3

29.5.2013
Hole Reservation Manager

18

Needed files 2/3

29.5.2013
Hole Reservation Manager

19

Needed files 3/3

29.5.2013
Hole Reservation Manager

20

Important items to know 1/2


When building service designer creates a circular hole reservation
(ifc) the length can not be exactly the same as diameter because
otherwise Tekla hole reservation part may be rotated 90 degrees.
Better to put length e.g. 10 mm longer. Tekla hole reservation part
can also be rotated manually and changed Accept status = 2 to get
real cut to part element correctly. But this is extra work. Similar effect
may happen sometimes also if all sides of cubical part have equal
length. Then it is also better to put some e.g. 5 mm extra length in
cut direction
In new version (09.04.2012->) in comment field a text REMARK
SHAPE will be written if ifc shape not correctly recognized. This
appears after refreshing the dialog. Even message appears usually
Tekla hole reservation part is correctly converted
It is better to have separate (smaller) ifc file for hole reservations. If
also reference pipes wanted be shown in Tekla drawings it is faster
when ifc files not subdivided. In this case only hole reservation ifc file
needs to be subdivided
Hole Reservation Manager

29.5.2013

21

Important items to know 2/2


IFC reference object hole reservation attributes need to be defined in
the following way so that Tekla can recognize them as hole
reservations. See previous Needed files slide for an example.
Object type = ProvisionForVoid
Shape, width height, diameter, system attributes are defined in the following
way

Pset_ProvisionForVoid.Shape
Pset_ProvisionForVoid.Width
Pset_ProvisionForVoid.Height
Pset_ProvisionForVoid.Diameter
Pset_ProvisionForVoid.System

If needed ifc file can also be edited to have correct syntax


Pset_ProvisionForVoid.Depth attribute is in the direction of void and shows
the length of void. Note: direction is different e.g. in wall and slab cases

Hole reservation manager works faster if ifc file subdivided before


hand
29.5.2013
Hole Reservation Manager

22

Potrebbero piacerti anche