Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Table of contents
1.
Pump data
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.
Performance range
3.
Product range
13
4.
Operating conditions
19
Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.
Pumped liquids
21
Pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Liquid temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended shaft seal for water/glycol mixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
21
22
24
6.
25
7.
27
8.
29
9.
32
10. TPE2
35
11. TPE3
39
43
47
80
15. Communication
81
16. Speed regulation of TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D pumps
82
Affinity equations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
83
85
86
Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Electrical data, mains-operated motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Electrical data, speed-controlled motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
20. Installation
91
Mechanical installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
97
Table of contents
Motors for TPE, TPE2 and TPE3 pumps fitted with 2-pole motors from 0.12 - 2.2 kW and 4-pole motors from 0.12 - 1.1
kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
MGE motors, 1.5 to 18.5 kW, 4-pole, and 3 to 22 kW, 2-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
22. EMC
109
110
111
28. Accessories
Unions and valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Counter-flanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Base plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blanking flanges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulating kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Grundfos sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MP 204 - advanced motor protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control MP 204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Potentiometer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grundfos GO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIU communication interface units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIM communication interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMC filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
114
114
126
150
188
192
192
193
195
197
198
198
198
200
202
202
203
203
204
208
210
214
215
219
220
220
221
221
222
222
223
224
225
226
227
228
229
231
Pump data
1. Pump data
Introduction
TP pumps are designed for applications such as
district heating systems
heating systems
air-conditioning systems
district cooling systems
water supply
industrial processes
industrial cooling.
The pumps are available with either mains-operated
motors (TP and TPD) or electronically
speed-controlled motors (TPE, TPED, TPE2, TPE2 D,
TPE3, TPE3 D).
The pumps are all single-stage, in-line centrifugal
pumps with mechanical shaft seal. The pumps are of
the close-coupled type, i.e. pump and motor are
separate units.
Fig. 1
TPE2 pumps
TPE3 pumps
1
Pump data
ATEX-approved TP pumps
On request, Grundfos offers TP and TPD pumps with
ATEX-approval.
See section Key application data, page 229.
Fig. 2
Pump data
Identification
Type key for TP, TPD, TPE, TPED
Code Example
TP
65
-120
/2
-S
-A
-F
-A
-BUBE
-120
-S
-A
-F
-A
-BUBE
Pump range
Electronically speed-controlled pump (Series 1000, 2000)
Twin-head pump
Nominal diameter of suction and discharge ports (DN)
Maximum head [dm]
S
A
A3
B
E
I
X
F
O
A
I
Z
B
O
Y
Pole number
TPE Series 2000 (with factory-fitted differential-pressure sensor)
Code for pump version (the codes may be combined):
Basic version
PN 25 flange
Oversize motor
With ATEX approval, certificate or test report, the second character of the code for pump version is an E
PN 6 flange
Special version
Code for pipework connection:
DIN flange
Union
Code for materials:
Basic version
Stainless steel 1.4308 pump housing and motor stool
Bronze pump housing and motor stool
Bronze impeller
Ductile cast-iron pump housing with cast iron impeller
Ductile cast-iron pump housing with bronze impeller
Code for shaft seal (incl. other plastic and rubber pump parts, except the neck ring)
TPE3
65
A
B
D
G
R
A
B
Q
U
B
Q
U
E
P
V
F
Performance range
2. Performance range
Performance range, TPE2, TPE3, PN 6, 10, 16
See page 114 for performance curves.
+
>P@
73('
73('
4>PK@
73('
73('
4>PK@
5
5
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 112.
The hatched area shows the performance range of TPE pumps.
5
5
4>PK@
4>OV@
31SROH+]
Performance range
S
+
>N3D@ >P@
2
TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D
S
+
>N3D@ >P@
31SROH+]
73
4>OV@
4>PK@
Performance range
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 112.
10
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 112.
The hatched area shows the performance range of TPE pumps.
4>OV@
4>PK@
31SROH+]
+
>P@
Performance range
S
>N3D@
2
TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D
Performance range
4>OV@
4>PK@
73
31SROH+]
S
+
>N3D@ >P@
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 112.
11
4>OV@
4>PK@
12
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 112.
S
>N3D@
+
>P@
73'
31SROH+]
Performance range
3. Product range
Product range, TPE2, TPE2 D, TPE3, TPE3 D
Pressure stage
Electronically
speed-controlled
motor
Materials
Pump
housing
Impeller
1)
Composite
PES-GF30
Stainless steel 1)
PN 6
PN 6/10
Cast iron
EN-GJL-250
DBUE
BQQE
BAQE
AUUE
PN 16
PN 10
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
BUBE
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE3, TPE3 D
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2, TPE2 D
Pump type
Voltage [V]
3 x 380-500 V
Shaft seal
1 x 200-240 V
Design
Product range
P2
[kW]
P2
[kW]
0.25
0.25
0.37
0.55
0.75
0.25
0.37
0.55
0.75
1.1
1.5
0.37
0.37
0.55
0.75
1.1
1.5
0.25
0.25
0.37
0.55
0.75
0.25
0.37
0.55
0.75
1.1
1.5
0.37
0.37
0.55
0.75
1.1
1.5
2.2
0.37
0.55
0.75
1.1
1.5
2.2
0.25
1.1
1.5
2.2
0.25
1.1
1.5
2.2
0.37
0.55
0.75
1.1
1.5
0.25
1.1
1.5
0.25
1.1
1.5
13
PN 25
PN 16
PN 10
Electronically
speed-controlled
motor
Voltage [V]
Voltage [V]
P2
P2
[kW] [kW]
P2
[kW]
0.12
0.18
0.37
0.12
0.25
0.37
0.25
0.37
0.37
0.55
0.75
1.1
1.5
0.12
0.25
0.25
0.37
0.37
0.55
0.75
1.1
1.5
0.37
0.75
0.75
1.1
1.5
0.55
1.1
1.5
0.12
0.18
0.37
0.12
0.25
0.37
0.25
0.37
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.12
0.25
0.25
0.37
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
0.37
0.75
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
15.0
18.5
22.0
0.55
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
3 x 380-500 V
Impeller
Mains-operated
motor
3 x 380-480 V
Pump housing
Pump type
14
Materials
1 x 200-240 V
Pressure
stage
3 x 380-415 V/
660-690 YV 2)
Shaft seal
3 x 220-240 V/
380-415 YV
Design
Cast iron
EN-GJL-150
Cast iron
EN-GJL-200
Cast iron
EN-GJL-250
Nodular cast iron
EN-GJS-400-18-LT
Bronze 1)
Stainless steel
Stainless steel
Cast iron
Composite
Bronze
1 x 220-230 V/
240 YV
Product range
P2
P2
P2
[kW] [kW] [kW]
0.12
0.18
0.37
0.12
0.25
0.37
1.5
2.2
2.2
3.0
4.0
5.5
3.0
4.0
5.5
0.12
0.25
0.37
2.2
3.0
4.0
5.5
7.5
11.0
3.0
4.0
5.5
7.5
11.0
2.2
3.0
4.0
5.5
7.5
11.0
15.0
15.0
18.5
22.0
3.0
4.0
5.5
7.5
11.0
15.0
15.0
18.5
22.0
2.2
3.0
4.0
5.5
7.5
11.0
15.0
3.0
4.0
5.5
7.5
11.0
15.0
PN 25
PN 16
PN 10
Voltage [V]
Voltage [V]
P2
[kW]
P2
P2
P2
[kW] [kW] [kW]
18.5
22.0
30.0
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
18.5
22.0
30.0
18.5
22.0
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
45.0
55.0
75.0
90.0
110.0
132.0
160.0
3 x 380-500 V
P2
P2
[kW] [kW]
3 x 380-480 V
Pump type
Impeller
Electronically
speed-controlled
motor
Cast iron
EN-GJL-150
Cast iron
EN-GJL-200
Cast iron
EN-GJL-250
Nodular cast iron
EN-GJS-400-18-LT
Bronze 1)
Stainless steel
Stainless steel
Cast iron
Composite
Bronze
1 x 220-230 V/
240 YV
Pump housing
Mains-operated
motor
1 x 200-240 V
Materials
3 x 380-415 V/
660-690 YV 2)
Pressure
stage
Shaft seal
3 x 220-240 V/
380-415 YV
Design
Product range
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22.0
Standard.
Bronze versions are only available as single-head pumps.
2)
2-pole motors above 5.5 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot.
1)
15
16
P2
P2
[kW] [kW]
P2
[kW]
0.12
0.25
0.25
0.25
0.37
0.55
0.12
0.25
0.25
0.55
0.75
1.1
0.25
0.37
0.55
0.75
1.1
1.5
0.25
0.55
0.75
1.1
1.5
0.37
0.75
1.1
1.5
0.55
1.1
1.5
0.12
0.25
0.25
0.25
0.37
0.55
0.12
0.25
0.25
0.55
0.75
1.1
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.25
0.55
0.75
1.1
1.5
2.2
3.0
4.0
0.37
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
0.55
1.1
1.5
2.2
3.0
4.0
5.5
5.5
7.5
11.0
15.0
18.5
22.0
2.2
3.0
4.0
4.0
5.5
7.5
3 x 380-500 V
Voltage [V]
3 x 380-480 V
Voltage [V]
1 x 200-240 V
Electronically
speed-controlled
motor
3 x 380-415 V/
660-690 YV 2)
Bronze
Cast iron
EN-GJL-250
PN 25
PN 16
PN 10
PN 6
DAQF
DQQE
DBUE
BQQE
BAQE
AUUE
BUBE
TP Series 300
TP Series 200
TP Series 100
Stainless steel
Pump type
Impeller
Bronze 1)
Pump housing
Mains-operated
motor
3 x 220-240 V/
380-415 YV
Materials
1 x 220-230 V/
240 YV
Pressure
stage
Shaft seal
Cast iron
Design
Product range
P2
P2
P2
[kW] [kW] [kW]
2.2
3.0
2.2
3.0
4.0
4.0
2.2
3.0
4.0
5.5
7.5
11.0
3.0
4.0
5.5
7.5
11.0
1.1
2.2
3.0
4.0
5.5
5.5
7.5
11.0
15.0
18.5
22.0
2.2
3.0
4.0
4.0
5.5
7.5
1.5
2.2
3.0
4.0
5.5
5.5
7.5
11.0
15.0
18.5
2.2
3.0
4.0
4.0
5.5
7.5
Voltage [V]
Voltage [V]
P2
P2
P2
[kW] [kW] [kW]
7.5
11.0
15.0
18.5
22.0
30.0
5.5
7.5
11.0
15.0
7.5
11.0
15.0
18.5
22.0
18.5
22.0
30.0
7.5
11.0
15.0
18.5
22.0
30.0
5.5
7.5
11.0
15.0
7.5
11.0
15.0
18.5
22.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
4.0
5.5
7.5
11.0
15.0
15.0
18.5
22.0
30.0
45.0
37.0
55.0
37.0
45.0
55.0
75.0
75.0
90.0
110
132
30.0
37.0
45.0
55.0
75.0
90.0
110.0
132.0
160.0
55.0
75.0
90.0
110.0
132.0
160.0
200.0
250.0
7.5
11.0
15.0
18.5
45.0
55.0
75.0
4.0
5.5
7.5
11.0
15.0
15.0
18.5
22.0
30.0
30.0
3 x 380-500 V
P2
[kW]
3 x 380-480 V
P2
P2
[kW] [kW]
1 x 200-240 V
Bronze
Stainless steel
Bronze 1)
Cast iron
EN-GJL-250
PN 25
PN 16
PN 10
DAQF
PN 6
DQQE
DBUE
AUUE
BUBE
TP Series 300
TP Series 200
TP Series 100
Impeller
Electronically
speed-controlled
motor
3 x 380-415 V/
660-690 YV 2)
BQQE
BAQE
TP 125-150/4
TP, TPD 125-190/4
TP, TPD 125-230/4
TP, TPD 125-300/4
TP, TPD 125-340/4
TP, TPD 125-400/4
TP 150-70/4
TP 150-110/4
TP 150-155/4
TP 150-170/4
TP, TPD 150-130/4
TP, TPD 150-160/4
TP, TPD 150-200/4
TP, TPD 150-220/4
TP, TPD 150-250/4
TP 150-260/4
TP 150-280/4
TP 150-340/4
TP 150-390/4
TP 150-450/4
TP 150-520/4
TP 150-660/4
TP 200-50/4
TP 200-70/4
TP 200-90/4
TP 200-130/4
TP 200-150/4
TP 200-160/4
TP 200-190/4
TP 200-200/4
TP 200-240/4
TP 200-270/4
TP 200-290/4
TP 200-320/4
TP 200-330/4
TP 200-360/4
TP 200-400/4
TP 200-410/4
TP 200-470/4
TP 200-530/4
TP 200-590/4
TP 200-660/4
TP 300-190/4
TP 300-220/4
TP 300-250/4
TP 300-290/4
TP 300-390/4
TP 300-420/4
TP 300-430/4
TP 300-500/4
TP 300-550/4
TP 350-230/4
TP 350-280/4
TP 350-310/4
TP 350-360/4
TP 350-420/4
TP 350-480/4
TP 350-530/4
TP 350-650/4
Pump type
Pump housing
Mains-operated
motor
3 x 220-240 V/
380-415 YV
Materials
1 x 220-230 V/
240 YV
Pressure
stage
Shaft seal
Cast iron
Design
Product range
5.5
7.5
11.0
15.0
7.5
11.0
15.0
18.5
18.5
4.0
5.5
7.5
11.0
15.0
15.0
18.5
17
P2
P2
[kW] [kW]
P2
[kW]
3 x 380-500 V
Voltage [V]
3 x 380-415 V/
660-690 YV 2)
Voltage [V]
3 x 220-240 V/
380-415 YV
Electronically
speed-controlled
motor
1 x 220-230 V/
240 YV
Cast iron
Stainless steel
Bronze 1)
Cast iron
EN-GJL-250
PN 25
PN 16
PN 10
PN 6
DAQF
Bronze
DQQE
DBUE
BQQE
BAQE
AUUE
BUBE
TP Series 300
TP Series 200
TP Series 100
350-780/4
400-470/4
400-510/4
400-540/4
400-670/4
400-720/4
400-760/4
TP
TP
TP
TP
TP
TP
TP
Pump type
Impeller
Mains-operated
motor
3 x 380-480 V
Materials
1 x 200-240 V
Pressure
stage
Shaft seal
Pump housing
Product range
Design
P2
P2
P2
[kW] [kW] [kW]
315.0
315.0
355.0
400.0
500.0
560.0
630.0
Standard.
Bronze versions are only available as single-head pumps.
2)
4-pole motors above 4 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot.
1)
125-60/6
125-70/6
125-80/6
125-100/6
125-130/6
125-160/6
150-60/6
150-70/6
150-90/6
150-110/6
Standard.
Bronze versions are only available as single-head pumps.
1)
18
3 x 380-415 V
Voltage [V]
3 x 380-480 V
Voltage [V]
1 x 200-240 V
Electronically
speed-controlled
motor
3 x 380-415 V/
660-690 YV
Bronze
Impeller
Stainless steel
Bronze 1)
Cast iron
EN-GJL-250
PN 25
PN 16
PN 10
PN 6
DBUE
AUUE
BUBE
TP Series 200
TP Series 100
TP Series 300
BQQE
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
BAQE
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
Pump type
Pump housing
Mains-operated
motor
3 x 220-240 V/
380-415 YV
Materials
1 x 220-230 V/
240 YV
Pressure
stage
Shaft seal
Cast iron
Design
P2
P2
P2
P2
P2
P2
[kW] [kW] [kW] [kW] [kW] [kW]
1.5
2.2
3.0
4.0
5.5
7.5
2.2
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
2.2
3.0
4.0
5.5
4. Operating conditions
System and test pressures
System pressure
Pressure
PN
PN
PN
PN
6
10
16
25
Test pressure
[bar]
[MPa]
[bar]
[MPa]
6
10
16
25
0.6
1.0
1.6
2.5
10
16
24
38
1.0
1.6
2.4
3.8
Ambient temperature
Operating conditions
Three-phase motors
2-pole
4-pole
6-pole
56
56
57
53
53
58
60
59.5
63
62
60
60
60
60.5
65.5
70
71
67
72
74
73
76
76
76
-
41
45
42
59.5
49.5
50
51
53
54
50
51
53
54
60
60
62
66
66
67
70
70
70
70
70
70
73
73
75
75
75
78
78
47
52
63
63
63
66
-
-20 - 60 C
-20 - 55 C
-20 - 50 C
-20 - 40 C
-20 - 40 C
Down to -30 C
19
Operating conditions
Installation altitude
If the ambient temperature exceeds maximum values
or if the motor is located more than 1,000 metres
above sea level, the motor output (P2) must be
reduced due to the low density and consequent low
cooling effect of the air. In such cases, it may be
necessary to use an oversize motor with a higher rated
output.
Pos.
Description
Fig. 3
Description
MGE motors:
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
Fig. 4
20
P2
[%]
1
0.99
0.98
0.97
0.96
0.95
0.94
0.93
0.92
0.91
0.90
0.89
0.88
5. Pumped liquids
Pumped liquids
Liquid temperature
Examples of liquids
Pump type
TP Series 100
TP Series 200
TP Series 300, 16-bar version
TP Series 300, 25-bar version
TP Series 300, DN400 version
TPE2, TPE3
Shaft seal
Temperature
BUBE
BQQE
BUBE
BQQE
0-120 C
-25 - +120 C
0-140 C
-25 - +120 C
BAQE
0-120 C (140 C) 1)
-25 - +120 C
-40 - +120 C
BQQE
DQQE
DAQF
0-150 C 3)
DBUE
0-150 C 2)
BUBE
0-120 C4)
-25 - +120 C
BQQE
Pumped liquids
1)
21
Pumped liquids
Legend
The shaft seal rubber parts must be replaced with FKM rubber.
Shaft seal
Pumped liquids
Notes
Additional
information
TPE2, TPE3
TP Series 100
TP Series
200
TP Series
300
PN 16
TP Series
300
PN 25
TP Series
300
DN 400
BUBE
BQQE
BUBE
BQQE
BUBE
BQQE
BQQE2)
DQQE
DAQF4)
DBUE
BUBE
DAQF2) + 4)
DAQF4)
BUBE
BQQE
BAQE
BQQE
DQQE
DAQF
DBUE
BUBE
DAQF2)
DAQF
DBUE
DAUE
DBUE
DBUE
Water
< 120 C
Groundwater
> 120 C
< 120 C
Boiler-feed water
BUBE
BQQE
BUBE
BQQE
< 140 C
< 150 C
< 120 C
BUBE
BQQE
< 120 C
BUBE
BQQE
BUBE
BQQE
BUBE
BQQE
> 120 C
Softened water
< 120 C
BUBE
BQQE
BUBE
BQQE
> 120 C
Brackish water
BUBE
BQQE
BAQE
BQQE
DQQE
DAQF
BUBE
BQQE
BAQE
BQQE
DQQE
DAQF
BUBE
DAQF
BUBE
BQQE
DAQF2)
BQQE
BAQE
DQQE
DAQF
BUBE
DAQF2)
DAQF
pH > 6.5, 40 C,
1000 ppm Cl-
BUBE
BQQE
BUBE
BQQE
BUBE
BQQE
BQQE
DQQE
< 120 C
BQQE
BQQE
BQQE
BQQE
DQQE
BQQE
BQQE
BQQE
BQQE
DQQE
BQQE
BQQE
BQQE
BQQE
BQQE
DQQE
BQQE
BQQE
BQQE
BQQE
DQQE
BQQE
BQQE
BQQE
BQQE
DQQE
DBUE
DBUE
DBUE
Coolants
Ethylene glycol
Glycerine (glycerol)
Potassium acetate
B, D, H
B, D, H
B, D, C, H
DQQE2)
< 90 C
< 120 C
DQQE2)
< 90 C
< 120 C
< 110 C
DQQE2)
< 90 C
Potassium formate
Propylene glycol
Brine sodium chloride
22
B, D, C, H
B, D, H
B, D, C, H
< 120 C
DQQE2)
< 90 C
< 120 C
DQQE2)
< 90 C
< 5 C, 30 %
BQQE
BQQE
BQQE
BQQE
DQQE2)
(To be continued)
DQQE
Shaft seal
Additional
information
TPE2, TPE3
TP Series 100
TP Series
200
TP Series
300
PN 16
TP Series
300
PN 25
TP Series
300
DN 400
B, E
BUBE
BQQE
BUBE
BQQE
BUBE
BQQE
BAQE
BQQE
DAQF
DQQE
DBUE
Corn oil
B, F, E
BUBV2) + 3)
BQQV2) + 3)
BUBV2)
BQQV2)
BUBV2)
BQQV2)
BAQV2)
BQQV2)
DAQF
DBUV2)
Olive oil
B, F, E
BUBV2) + 3)
BQQV2) + 3)
BUBV2)
BQQV2)
BUBV2)
BQQV2)
BAQV2)
BQQV2)
DAQF
DBUV2)
Peanut oil
B, F, E
BUBV2) + 3)
BQQV2) + 3)
BUBV2)
BQQV2)
BUBV2)
BQQV2)
BAQV2)
BQQV2)
DAQF
DBUV2)
D, B, F, E
BUBV2) + 3)
BQQV2) + 3)
BUBV2)
BQQV2)
BUBV2)
BQQV2)
BAQV2)
BQQV2)
DAQF
DBUV2)
B, F, E
BUBV2) + 3)
BQQV2) + 3)
BUBV2)
BQQV2)
BUBV2)
BQQV2)
BAQV2)
BQQV2)
DAQF
DBUV2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
BQQE
(BQQV)2)
DQQE
DQQE2)
DQQE
DQQE2)
< 40 C, < 2 %
BUBE
BQQE
BUBE
BQQE
BUBE
BQQE
BQQE
DAQF
DQQE
DQQE2)
< 20 C, < 15 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
A, B
< 20 C, < 30 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Potassium bicarbonate
< 20 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Potassium carbonate
< 20 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Potassium permanganate
< 20 C, < 10 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Potassium sulphate
< 20 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium acetate
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium bicarbonate
< 20 C, < 2 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium carbonate
< 20 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium nitrate
< 0 C, < 40 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium nitrite
< 20 C, < 40 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
< 90 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium sulphate
< 20 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium sulphite
< 20 C, < 1 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Calcium hydroxide
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Potassium hydroxide
< 20 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Sodium hydroxide
< 40 C, < 20 %
BQQE
BQQE
BQQE
BQQE
DQQE
DQQE2)
Pumped liquids
Notes
Synthetic oils
Silicone oil
Pumped liquids
Vegetable oils
Rapeseed oil
Soybean oil
< 80 C
Cleaning agents
Soap (salts of fatty acids)
A, E, (F)
< 80 C
A, E, (F)
< 80 C
Oxidants
Hydrogen peroxide
Salts
Ammonium bicarbonate
Calcium acetate
Alkalis
Ammonium hydroxide
1)
BAQE must not be used for potable water. For potable water, Grundfos recommends that you use a BBQE shaft seal.
The shaft seal is not standard, but available on request.
3)
Applies only for TPE2.
4) Must not be used for potable water.
2)
23
Glycol content
[%]
50
40
30
BQQE
/DQQE
20
10
-25-20
-10
10
20
30
40
50
60
70
80
90
100
110
120
Temperature [C]
Fig. 5
Pumped liquids
Glycol content
[%]
50
40
20
10
-10
10
20
30
40
50
60
70
80
90
Temperature [C]
Fig. 6
24
BQQV
30
GrB2850 - Gr8261
TP Series 100
Fig. 7
Flow rate:
Up to 90 m3/h
Head:
Up to 27 m
Liquid temperature (TP Series 100): -25 - +120 C
Liquid temperature (TP Series 200): -25 - +140 C
Maximum operating pressure:
Up to 16 bar
Direction of rotation:
Counter-clockwise
Construction
Grundfos TP Series 100 and Series 200 pumps are
single-stage, close-coupled pumps with in-line suction
and discharge ports of identical diameter.
The pumps are fitted with a fan-cooled asynchronous
motor. Motor and pump shafts are connected via a
rigid two-part coupling.
TP Series 100 pumps with union connection are
available as single-head (TP) pumps.
TP Series 200 pumps are available as single-head
(TP) and twin-head (TPD) pumps.
TP Series 200 pumps have PN 6 or PN 10 flanges.
The pumps are fitted with an unbalanced mechanical
shaft seal.
The pumps are of the top-pull-out design, i.e. the
power head (motor, pump head and impeller) can be
removed for maintenance or service while the pump
housing remains in the pipework.
The twin-head pumps are designed with two parallel
power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped
liquid and prevents backflow of liquid into the idle
pump head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
TP, TPD Series 100 and 200 pumps are fitted with
high-efficiency motors.
Pumps with a bronze or stainless-steel pump housing
are suitable for circulation of domestic hot water.
Technical data
Fig. 8
Material
EN/DIN
EN-JL 1020
EN-JL 1030
1.4308
Pump housing
Impeller
Composite PES/PP 30 % GF
Shaft
Stainless steel
1.4057
Coupling
0.7040
Pump head
EN-JL 1030
1.4308
Tungsten carbide
Silicon carbide
Stationary seat
Carbon (resin-impregnated),
silicon carbide
25
2
1
Fig. 9
Connections
EN/DIN
EN-JL 1040
2.1093
Pump housing
Impeller
Stainless steel
1.4301
Shaft
Stainless steel
1.4305
Coupling
0.7040
Pump head
0.6025
2.1093
Secondary seals
EPDM
Carbon (resin-impregnated),
silicon carbide
Version KU according to EN
TP Series 100
12756
TP, TPD Series Version NU according to EN
200
12756
12 and 16 mm
EPDM
Tungsten carbide/carbon
Silicon carbide/silicon carbide
26
Material
Gr8259
Materials
Fig. 10
TP Series 300
Technical data
Head [m]
Liquid temperature [C]
Maximum operating
pressure [bar]
Direction of rotation
*
3
PN 16 version
PN 25 version
Up to 2000
Up to 4500
Up to 93
Up to 140
-25 - +140
-40 - +150*
16
25
2
1
TM04 9586 2115
Clockwise
Fig. 11
Construction
Material specification
TP Series 300, PN 16
Pos. Component
Material
EN/DIN
EN-JL 1040
Pump housing
Impeller
Stub shaft
Stainless steel
Two-part stub shaft Stainless steel/steel
1.4301
1.4301/1.0301
Pump head/motor
stool
EN-JL 1040
Secondary seals
EPDM
Metal-impregnated
carbon
Silicon carbide
Stationary seat
Silicon carbide
Wear ring
Bronze CuSn10
2.1093
TP Series 300, PN 25
Pos. Component
Material
EN/DIN
EN-JS 1025
Pump housing
Impeller
Stub shaft
Stainless steel
Two-part stub shaft Stainless steel/steel
1.4301
1.4301/1.0301
Motor stool
EN-JL 1040
Secondary seals
EPDM
FXM
Metal-impregnated
carbon
Silicon carbide
Stationary seat
Silicon carbide
Wear ring
Bronze CuSn10
2.1093
27
Pump housing
Material
EN/DIN
EN-JS1020
Impeller
Pump shaft
Stainless steel
1.4436
Coupling
EN-JL1040
Motor stool
EN-JL1040
Secondary seals
EPDM rubber
Bronze CuSn10
2.1093
Tungsten carbide
Connections
TP Series 300 pumps have PN 16 or PN 25 flanges. All
dimensions are according to ISO 7005-2 or EN 1092-2.
28
Electrocoating
Spray painting
x
2x
Electrocoating includes:
1. Alkaline cleaning.
2. Pretreatment with zinc phosphate coating.
3. Cathodic electrocoating (epoxy).
4. Curing of paint film at 200-250 C.
For low-temperature applications at a high humidity,
Grundfos offers TP pumps with extra surface treatment
to avoid corrosion. These pumps are available on
request.
Applications
Fig. 12
HH
[m]
[m]
100 % (110 %)
Flow rate:
Head:
Liquid temperature:
Maximum operating pressure:
Motor sizes (single-phase):
Motor sizes (three-phase):
Up to 340 m3/h
Up to 90 m
-25 to 140 C
16 bar
0.12 to 1.5 kW
0.12 to 22 kW
Construction
TPE, TPED Series 1000 pumps are based on TP, TPD
Series 100, 200 and 300 pumps.
The main difference between the TP and the TPE
Series 1000 pump range is the motor. The MGE motor
of TPE Series 1000 pumps has a built-in frequency
converter for continuous adjustment of the pressure to
the flow rate. TPE, TPED pumps with 2-pole motors
below 3 kW and 4-pole motors below 1.5 kW are fitted
with permanent-magnet motors which have an
efficiency that exceeds the IE4 demands - including
the energy consumption of the integrated frequency
converter (compared to IE levels in IEC 60034-30-1
Ed. 1).
TPE Series 1000 pumps are suitable for applications
where the pressure, temperature, flow rate or another
parameter is to be controlled on the basis of signals
from a sensor at some point in the system.
Note: TPE Series 1000 pumps are not fitted with a
sensor from factory.
For further information on construction and materials
of TPE Series 1000 pumps, see pages 25 to 28.
25 %
Fig. 13
3h]
QQ[m
[m/h]
Technical data
29
The charts below show possible control modes of TPE Series 1000 pumps in different applications.
System application
In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems.
Two-pipe heating systems with thermostatic valves and the following:
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary
circuit.
Air-conditioning systems with the following:
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.
Pump type
H
All
H
All
Q
Constant temperature
H
All
Q
Constant differential temperature
H
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
Q
Constant curve
If an external controller is installed, the pump is able to change from one constant
curve to another, depending on the value of the external signal.
The pump can also be set to operate according to the maximum or minimum
curve:
The maximum curve mode can be used in periods in which a maximum flow is
required.
This operating mode is for instance suitable for hot-water priority.
The minimum curve mode can be used in periods in which a minimum flow is
required.
H
All
Q
Constant flow rate
H
In systems requiring a constant flow, independently of pressure drop.
Examples:
chillers for air-conditioning
heating surfaces
cooling surfaces.
All
Q set
30
System application
Pump type
Constant level
H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
process water tanks
boiler condensate tanks.
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
parallel (two to four pumps) and without the use of external controllers. The
pumps in a multipump system communicate with each other via the wireless
GENIair connection or the wired GENI connection.
TPE 50-570/2-S
60 100 %
50
20
10
5
Fig. 14
10
15
20
25
30
35
40
45
50
55
60 Q(m3/h)
100 %
30
0
0
Alternating operation
Standby operation
101 %
40
3 x 400 V, 50 Hz
Q = 45.1 m3/h
H = 45 m
n = 100 %
109 %
107 %
105 %
103 %
Control options
Communication with TPE, TPED Series 1000 pumps is
possible via a central building management system,
remote control (Grundfos GO) or control panel.
The purpose of controlling a TPE, TPED Series 1000
pump is to monitor and control the pressure,
temperature, flow rate and liquid level of the system.
For further information on control options of TPE
pumps, see page 81.
31
Applications
Fig. 15
Technical data
Flow rate:
Head:
Liquid temperature:
Maximum operating pressure:
Motor sizes (single-phase):
Motor sizes (three-phase):
Up to 340 m3/h
Up to 90 m
-25 to 140 C
16 bar
0.12 to 1.5 kW
0.12 to 22 kW
25 %
Construction
Fig. 16
32
Fig. 17
Q [m/h]
[m h]
Q
The charts below show possible control modes of TPE Series 2000 pumps in different applications.
System application
In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems.
Two-pipe heating systems with thermostatic valves and the following:
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary
circuit.
Air-conditioning systems with the following:
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.
In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems.
Two-pipe heating systems with thermostatic valves and the following:
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary
circuit.
Air-conditioning systems with the following:
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.
In systems with relatively small pressure losses in the distribution pipes.
Two-pipe heating systems with thermostatic valves and the following:
dimensioned for natural circulation
small pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching) or
modified to a high differential temperature between flow pipe and return pipe
(for example district heating).
Underfloor heating systems with thermostatic valves.
One-pipe heating systems with thermostatic valves or pipe balancing valves.
Primary circuit pumps in systems with small pressure losses in the primary
circuit.
Pump type
Proportional pressure
H
Hset
All
Hset
2
Q
Constant differential pressure
(with differential-pressure sensor
located in the system)
H
0.12 - 2.2 kW, 2 pole
0.12 - 1.1 kW, 4 pole
Q
Constant differential pressure
H
All
Q
Constant curve
If an external controller is installed, the pump is able to change from one constant
curve to another, depending on the value of the external signal.
The pump can also be set to operate according to the maximum or minimum curve:
The max. curve mode can be used in periods in which a maximum flow is
required.
This operating mode is for instance suitable for hot-water priority.
The minimum curve mode can be used in periods in which a minimum flow is
required.
H
All
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
parallel (two to four pumps) without the use of external controllers. The pumps in a
multipump system communicate with each other via the wireless GENIair
connection or the wired GENI connection.
33
TPE 50-570/2-S
60 100 %
50
3 x 400 V, 50 Hz
Q = 45.1 m3/h
H = 45 m
n = 100 %
109 %
107 %
105 %
103 %
101 %
100 %
40
30
20
10
0
0
Fig. 18
10
15
20
25
30
35
40
45
50
55
60 Q(m3/h)
Control options
Communication with TPE, TPED Series 2000 pumps is
possible via a central building management system,
remote control (Grundfos GO) or control panel.
The purpose of controlling TPE, TPED Series 2000
pumps is to monitor and control the pressure,
temperature, flow rate and liquid level of the system.
For further information on control options of TPE
pumps, see page 81.
34
10
TPE2
10. TPE2
TM05 8250 2212 - TM05 8252 2212
Materials
Fig. 19
Technical data
Up to 120 m3/h
Up to 25 m
-25 to 120 C (140 C
for a short period)
Maximum operating pressure: 16 bar
Motor sizes (single-phase):
0.25 to 1.5 kW
Motor sizes (three-phase):
0.25 to 2.2 kW
Flow rate:
Head:
Liquid temperature:
Construction
Via an external signal (from a sensor or a controller),
TPE2 pumps allow for any configuration and control
method required, i.e. constant pressure, temperature,
flow or level.
The permanent-magnet motor of TPE2 pumps has a
built-in frequency converter for continuous adjustment
of the pressure to the flow rate.
The TPE2 range is a preset solution for quick and safe
installation.
TPE2 pumps are available as single-head (TPE2) and
twin-head (TPE2 D) pumps.
TPE2 pumps have PN 6, PN 10 or PN 16 flanges.
The pumps are fitted with an unbalanced mechanical
shaft seal.
The power head (motor, pump head and impeller) and
pump housing are held together by a specially
designed clamp. The clamp allows for fast
repositioning of the pump housing and fast service of
the pump.
The twin-head pumps are designed with two parallel
power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped
liquid and prevents backflow of liquid into the idle
pump head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
Pumps with stainless steel pump housing (version I)
are suitable for circulation of domestic hot water.
Fig. 20
Material specification
Pos. Component
1
Pump housing
Material
EN/DIN
EN1561
EN 1.4308
Impeller
Composite PES-GF30
Neck ring
Stainless steel
EN 1.4404
Pump head/motor
stool
EN1561
EN 1.4308
Secondary seals
EPDM
Tungsten carbide
Silicon carbide
Stationary seat
Carbon
(resin-impregnated)
Silicon carbide
Stub shaft
Stainless steel
EN 1.4404
35
10
TPE2
Applications
Constant curve
TPE2 pumps are factory-set to control mode constant
curve.
H
H
[m]
[m]
Minimum speed
3
QQ[m
h]
[m/h]
Fig. 21
Maximum speed
System application
In systems with relatively large pressure losses in the distribution pipes and in air-conditioning
and cooling systems.
Two-pipe heating systems with thermostatic valves and the following:
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total quantity of water
flows (for example boiler, heat exchanger and distribution pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary circuit.
Air-conditioning systems with the following:
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.
Pump type
H
All
Q
Constant differential pressure
H
All
Q
Constant temperature and constant
differential temperature
H
All
Q
Constant curve
If an external controller is installed, the pump is able to change from one constant curve to
another, depending on the value of the external signal.
The pump can also be set to operate according to the maximum or minimum curve, like an
uncontrolled pump:
The maximum curve mode can be used in periods in which a maximum flow is required.
This operating mode is for instance suitable for hot-water priority.
The minimum curve mode can be used in periods in which a minimum flow is required.
This operating mode is for instance suitable for manual night setback instead of automatic
night setback.
36
H
All
System application
Pump type
TPE2
10
H
In systems requiring a constant flow, independently of pressure drop.
Examples:
chillers for air-conditioning
heating surfaces
cooling surfaces.
All
Q set
Constant level
H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
process water tanks
boiler condensate tanks.
All
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in parallel (two to
four pumps) and twin-head pumps without the use of external controllers. The pumps in a
multipump system communicate with each other via the wireless GENIair connection or the
wired GENI connection.
"Assist" menu
"Multipump setup"
All
37
10
TPE2
Multipump system
Cascade operation
Alternating operation
Only one pump is operating at a time. The change from
one pump to the other depends on time or energy. If a
pump fails, the other pump will take over automatically.
Pump system:
Twin-head pump.
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
Backup operation
One pump is operating continuously. The backup
pump is operated at intervals to prevent seizing up. If
the duty pump stops due to a fault, the backup pump
will start automatically.
Pump system:
Twin-head pump.
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
38
Control options
Communication with TPE2 pumps is possible via a
central building management system, Grundfos GO or
control panel.
The purpose of controlling TPE2 pumps is to monitor
and control the pressure, temperature, flow rate and
liquid level of the system.
For further information on control options of TPE2
pumps, see page 81.
11
Fig. 22
TPE3
11. TPE3
The twin-head pumps are designed with two parallel
power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped
liquid and prevents backflow of liquid into the idle
pump head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
Pumps with stainless steel pump housing (version I)
are suitable for circulation of domestic hot water.
Materials
Technical data
Up to 120 m3/h
Up to 25 m
-25 to 120 C (140 C
for a short period)
Maximum operating pressure: 16 bar
Motor sizes (single-phase):
0.25 to 1.5 kW
Motor sizes (three-phase):
0.25 to 2.2 kW
TM05 8200 2113
Flow rate:
Head:
Liquid temperature:
Construction
TPE3 pumps have built-in differential-pressure and
temperature sensor.
The permanent-magnet motor of TPE3 pumps have a
built-in frequency converter for continuous adjustment
of the pressure to the flow rate.
The TPE3 range is a preset solution for quick and safe
installation.
TPE3 has a colour display for easy and intuitive pump
setup and with full access to all functions.
Fig. 24
Material specification
Pos. Component
1
Pump housing
Material
EN/DIN
Impeller
Composite PES-GF30
Neck ring
Stainless steel
Pump head/motor
stool
Secondary seals
EPDM
EN 1.4404
Tungsten carbide
Rotating seal face
Silicon carbide
Fig. 23
Stationary seat
Carbon
(resin-impregnated)
Silicon carbide
Stub shaft
Stainless steel
EN 1.4404
39
11
TPE3
Applications
AUTOADAPT
TPE3 pumps are factory-set to AUTOADAPT which
continuously adapts the pump performance according
to the actual system characteristic.
H
H
[m]
[m]
Minimum speed
Fig. 25
Q [m/h]
[m h]
Q
Maximum speed
System application
Pump type
AUTOADAPT
Recommended for most heating systems, especially in systems with relatively large
pressure losses in the distribution pipes. See description under proportional
pressure.
In replacement situations where the proportional-pressure duty point is unknown.
The duty point has to be within the AUTOADAPT operating range. During operation,
the pump automatically makes the necessary adjustment to the actual system
characteristics.
This setting ensures minimum energy consumption and low noise level from the
valves, and therefore reduces operating costs and increases comfort.
The FLOWADAPT control mode is a combination of AUTOADAPT and FLOWLIMIT.
This control mode is suitable for systems where a maximum flow limit, FLOWLIMIT,
is desired. The pump continuously monitors and adjusts the flow, thus ensuring that
the selected FLOWLIMIT is not exceeded.
Main pumps in boiler applications where a steady flow through the boiler is
required. No extra energy is used for pumping too much liquid into the system.
In systems with mixing loops, the control mode can control the flow in each loop.
Benefits:
Enough water for all loops at peak load conditions if each loop has been set to
the right maximum flow.
The dimensioned flow for each zone (required heat energy) is determined by the
flow from the pump.
This value can be set precisely in the FLOWADAPT control mode without the use
of pump throttling valves.
When the flow is set lower than the balancing valve setting, the pump ramps
down instead of losing energy by pumping against a balancing valve.
Cooling surfaces in air-conditioning systems operate at high pressure and low
flow.
In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems.
Two-pipe heating systems with thermostatic valves and the following:
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary
circuit.
Air-conditioning systems with the following:
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.
40
H
All
FLOWADAPT
H
All
Proportional pressure
H
Hset
All
Hset
2
System application
In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems.
Two-pipe heating systems with thermostatic valves and the following:
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary
circuit.
Air-conditioning systems with the following:
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.
In systems with relatively small pressure losses in the distribution pipes.
Two-pipe heating systems with thermostatic valves and the following:
dimensioned for natural circulation
small pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching)
modified to a high differential temperature between flow pipe and return pipe
(for example district heating).
Underfloor heating systems with thermostatic valves.
One-pipe heating systems with thermostatic valves or pipe balancing valves.
Primary circuit pumps in systems with small pressure losses in the primary
circuit.
Pump type
TPE3
11
H
All
Q
Constant differential pressure
H
All
Q
Constant temperature and constant
differential temperature
H
All
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
parallel (two to four pumps) and twin-head pumps without the use of external
controllers. The pumps in a multipump system communicate with each other via the
wireless GENIair connection or the wired GENI connection.
"Assist" menu
"Multipump setup"
All
41
11
TPE3
Multipump system
Cascade operation
Alternating operation
Only one pump is operating at a time. The change from
one pump to the other depends on time or energy. If a
pump fails, the other pump will automatically take over.
Pump system:
Twin-head pump.
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
Backup operation
The duty pump is operating continuously and the
backup pump operates in intervals to prevent seizing
up. If the duty pump stops due to a fault, the backup
pump will start automatically.
Pump system:
Twin-head pump.
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
42
Control options
Communication with TPE3 pumps is possible via the
control panel, Grundfos GO or a central building
management system.
The purpose of controlling TPE3 pumps is to monitor
and control the pressure, temperature, flow rate of the
system.
For further information on control options of TPE3
pumps, see page 81.
4)
4)
4)
4)
4)
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 1000
4-pole
TPE2,
TPE2 D
0.25 - 2.2 kW
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 2000
4-pole
E-pump functions
TPE3,
TPE3 D
Control panel
0.25 - 2.2 kW
E-pump type
Overview of functions
12
4)
Control mode
4)
4)
Flow limit
4)
Analog inputs
Analog input 1
4)
Analog input 2
4)
4)
3) + 4)
3) + 4)
Analog input 3
Built-in Grundfos sensor
3)
3)
Pt100/1000 inputs
Pt100/1000 input 1
3)
3)
3) + 4)
3) + 4)
Pt100/1000 input 2
3)
3)
3) + 4)
3) + 4)
Digital inputs
Digital input 1
4)
4)
Digital input 2
3)
3)
3) + 4)
3) + 4)
Digital inputs/outputs
Digital in/output 3
Digital in/output 4
3)
3)
4)
4)
3) + 4)
3) + 4)
4)
4)
Signal relay 1
4)
4)
Signal relay 2
4)
4)
3)
3)
3) + 4)
3) + 4)
3)
3)
3) + 4)
3) + 4)
3)
3)
3) + 4)
3) + 4)
4)
4)
4)
4)
4)
4)
4)
Relay outputs
Analog output
Output signal
Function of analog output
Controller settings
Operating range
Setpoint influence
3)
3)
3) + 4)
3) + 4)
4)
4)
4)
4)
4)
4)
4)
4)
4)
4)
4)
4)
Ramps
4)
4)
4)
4)
4)
4)
4)
4)
4)
4)
4)
Limit-exceeded function
Special functions
Standstill heating
Communication
Pump number
Enable/disable radio communication
General settings
4)
4)
Available.
1) Only 11-22 kW.
2)
Lubricated, only 11-22 kW.
3) Only available if an advanced functional module is fitted.
4)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1 kW, 4-pole.
43
12
4)
4)
4)
4)
4)
4)
Resulting setpoint
4)
4)
Liquid temperature
Speed
4)
4)
4)
4)
4)
4)
4)
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 1000
4-pole
Pump performance
TPE2,
TPE2 D
0.25 - 2.2 kW
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 2000
4-pole
Operating status
E-pump functions
TPE3,
TPE3 D
Control panel
0.25 - 2.2 kW
Overview of functions
E-pump type
4)
3)
3)
3) + 4)
3) + 4)
4)
4)
Heat energymonitor
Operating log
4)
4)
4)
4)
3) + 4)
3) + 4)
Analog output
Fitted modules
Date and time
3)
3)
Product identification
4)
4)
4)
4)
Multipump system
4)
4)
Start/stop
Max. curve
Min. curve
Alarm reset
Operating indication
Fault indication
Flow in %
External control
Stop
Setpoint
Start/stop
Max. curve
Min. curve
Alarm reset
Operating indication
Fault indication
Available.
1)
Only 11-22 kW.
2) Lubricated, only 11-22 kW.
3)
Only available if an advanced functional module is fitted.
4)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1 kW, 4-pole.
44
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 1000
4-pole
TPE2,
TPE2 D
0.25 - 2.2 kW
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 2000
4-pole
E-pump functions
0.25 - 2.2 kW
Control panel
TPE3,
TPE3 D
E-pump type
Overview of functions
12
Start/stop
Max. curve
Min. curve
Alarm reset
Operating indication
Fault indication
Operating mode
Control mode
3)
3)
3)
3)
FLOWLIMIT
Temperature influence
Buttons on product
Controller
Operating range
Ramps
Pump number
Radio communication
Sensor type
Analog input 1
Analog input 2
Analog input 3
3)
3)
3)
3)
Pt100/1000 input 1
3)
3)
3)
3)
Pt100/1000 input 2
3)
3)
3)
3)
Digital input 1
Digital input 2
3)
3)
3)
3)
Digital in/output 3
Digital in/output 4
3)
3)
3)
3)
Predefined setpoint
3)
3)
3)
3)
3)
3)
3)
3)
Analog output
Signal relay 1
Signal relay 2
1)
Limit 1 exceeded
Limit 2 exceeded
Standstill heating
2)
2)
Service
Store settings
Recall settings
Undo
Pump name
Unit configuration
Available.
1) Only 11-22 kW.
2)
Lubricated, only 11-22 kW.
3) Only available if an advanced functional module is fitted.
4)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1 kW, 4-pole.
45
12
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 2000
4-pole
0.25 - 2.2 kW
3-22 kW,
TPE, TPED
2-pole
1.5 - 18.5 kW, Series 1000
4-pole
Power consumption
Energy consumption
TPE2,
TPE2 D
Resulting setpoint
Actual controlled value
E-pump functions
TPE3,
TPE3 D
Control panel
0.25 - 2.2 kW
Overview of functions
E-pump type
Operating hours
Pt100/1000 input 1
3)
3)
3)
3)
Pt100/1000 input 2
3)
3)
3)
3)
Analog output
3)
3)
3)
3)
Analog input 1
Analog input 2
Analog input 3
3)
3)
3)
3)
Digital input 1
Digital input 2
3)
3)
Digital in/output 3
Digital in/output 4
3)
3)
3)
3)
3)
3)
Fitted modules
Trend data
Heat energymonitor
Start/stop
Max. curve
Min. curve
Operating indication
Pump status
Predefined setpoint
Start/stop
Alarm resetting
Analog output
Available.
1)
Only 11-22 kW.
2)
Lubricated, only 11-22 kW.
3)
Only available if an advanced functional module is fitted.
4) The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1 kW, 4-pole.
46
Additional functions
Twin-head pump function
Optional functions
Pos.
Fitted as
standard
Option
TPE3, TPE3 D
TPE2, TPE2 D
TPE Series
1000
Remote controls
Grundfos GO.
See section Grundfos GO on page 55.
If the power supply to the pump is switched off, the
settings will be stored.
Description
Grundfos Eye
Shows the operating status of the pump.
See page 76 for further information.
TPE Series
2000
Symbol
13
Setpoint setting
Set the desired setpoint of the pump by pressing
or
. The light fields on the control panel will indicate
the setpoint set.
Pump in differential-pressure control mode
The following example applies to a pump in an
application where a pressure sensor gives a feedback
to the pump. If the sensor is retrofitted to the pump, it
must be set up manually as the pump does not
automatically register a connected sensor.
Figure 27 shows that the light fields 5 and 6 are
activated, indicating a desired setpoint of 3 metres with
a sensor measuring range from 0 to 6 metres. The
setting range is equal to the sensor measuring range.
m
Fig. 26
4
Stop
0
Fig. 27
47
13
Q
Fig. 30
Fig. 28
Start/stop of pump
Q
Fig. 29
48
Option
TPE3, TPE3 D
TPE2, TPE2 D
TPE Series
2000
TPE Series
1000
Example
Figure 32 shows that light fields 5 and 6 are activated,
indicating a desired setpoint of 3.4 m. The sensor
measuring range is 0 to 6 m. The setting range is equal
to the sensor measuring range (see sensor
nameplate).
Pump variant
Fig. 32
13
Buttons
Example
Light fields
Indicator lights
Setpoint setting
Note: The setpoint can only be set when the operating
mode is "Normal".
Set the desired setpoint by pressing
or .
The light fields on the control panel will indicate the
setpoint set.
Fig. 33
Fig. 31
49
13
Fitted as
standard
Option
TPE3, TPE3 D
TPE2, TPE2 D
TPE Series
2000
Q
Fig. 34
TPE Series
1000
Press
continuously to change to the minimum curve
of the pump (bottom light field flashes). See fig. 35.
To change back, press
continuously until the
desired setpoint is indicated.
Q
Fig. 35
Fig. 36
Start/stop of pump
Start the pump by continuously pressing
until the
desired setpoint is indicated.
Stop the pump by continuously pressing
until none
of the light fields are activated and the green indicator
light flashes.
50
Pos.
Description
Fig. 37
Fig. 40
(pos. 2)
13
Proportional pressure
Press
continuously to change to the minimum curve
of the pump (MIN illuminates). See fig. 41.
To change back, press
continuously until the
desired head is indicated.
H
Fig. 38
Fig. 41
0.25 x Hmax.
0.9 x Hmax.
Start/stop of pump
Constant pressure
Figure 39 shows that light fields 5 and 6 are activated,
indicating a desired head of 3.4 metres. The setting
range is between 1/8 (12.5 %) of maximum head and
maximum head.
0.125 x Hmax.
Fig. 39
Hmax.
51
13
Menu structure
The pump incorporates a startup guide which is started
at the first startup. After the startup guide, the four
main menus will appear in the display.
Pump variant
Fitted as
standard
Option
TPE3, TPE3 D
TPE2, TPE2 D
2. Status
3. Settings
TPE Series
2000
TPE Series
1000
1. Home
4. Assist
This menu enables assisted pump setup, provides a
short description of the control modes and offers fault
advice.
See section Assist on page 75.
4
5
Fig. 42
Pos.
Description
Grundfos Eye
Shows the operating status of the pump.
See section Grundfos Eye on page 76 for
further information.
1
2
52
13
TPE2, TPE2 D
TPE2, TPE2 D
Analog input 3
1)
1)
1)
1)
Pt100/1000 input 1
1)
1)
1)
1)
Pt100/1000 input 2
1)
1)
1)
1)
1)
1)
1)
1)
Status
Operating status
Operating mode, from
Control mode
Pump performance
Actual controlled value
Max. curve and duty point
Resulting setpoint
Liquid temperature
Speed
Acc. flow, specific energy
Power and energy consumption
Measured values
Analog input 1
Analog input 2
Analog output
Warning and alarm
Actual warning and alarm
Warning log
Alarm log
Heat energymonitor
Heat power
Heat energy
Flow rate
Volume
Hour counter
Temperature 1
Temperature 2
Differential temp.
Operating log
Operating hours
Trend data
Fitted modules
Date and time
Product identification
Motor bearing monitoring
Multipump system
System operating status
System performance
System input power and energy
Pump 1, multipump sys.
Pump 2, multipump sys.
Pump 3, multipump sys.
1)
TPE3, TPE3 D
Home
TPE3, TPE3 D
Main menus
Section
Page
58
1)
1)
1)
1)
53
13
TPE2, TPE2 D
TPE3, TPE3 D
Section
Setpoint
Setpoint
58
Operating mode
Operating mode
58
59
Control mode
Control mode
59
Flow limit
FLOWLIMIT
64
65
Analog inputs
Analog inputs
65
Pt100/1000 inputs
66
Digital inputs
66
Digital inputs/outputs
67
Relay outputs
67
Analog output
68
Settings
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
Relay output 1
Relay output 2
1)
1)
1)
1)
Output signal
1)
1)
1)
1)
Analog output
1)
1)
1)
1)
Operating range
Operating range
69
Setpoint influence
Setpoint influence
70
70
1)
1)
1)
1)
Predefined setpoints
72
Temperature influence
73
Monitoring functions
73
Limit-exceeded function
73
Special functions
74
Limit-exceeded function
Special functions
74
Ramps
Ramps
74
Communication
74
Pump number
Pump number
74
74
General settings
74
TPE2, TPE2 D
Communication
TPE3, TPE3 D
Standstill heating
General settings
Assist
54
Relay outputs
1)
Page
Section
Multipump setup
Page
75
Grundfos GO
13
+
2
Fig. 43
Pos.
Description
Grundfos MI 202:
Add-on module which can be used in conjunction with an
Apple iPhone or iPod with 30-pin connector and iOS 5.0 or
later, e.g. fourth generation iPhone or iPod.
Grundfos MI 204:
Add-on module which can be used in conjunction with an
Apple iPhone or iPod with Lightning connector, e.g. fifth
generation iPhone or iPod.
(The MI 204 is also available together with an Apple iPod
touch and a cover.)
Grundfos MI 301:
Separate module enabling radio or infrared communication.
The module can be used in conjunction with an Android or
iOS-based smart device with Bluetooth connection.
Communication
When Grundfos GO communicates with the pump, the
indicator light in the middle of Grundfos Eye flashes
green. See section Grundfos Eye on page 76.
Communication must be established using one of
these communication types:
radio communication
infrared communication.
Radio communication
Radio communication can take place at distances up
to 30 metres. It is necessary to enable communication
by pressing
or
on the pump control panel.
Infrared communication
When communicating via infrared light, point Grundfos
GO at the pump control panel.
55
13
Resulting setpoint
TPE2, TPE2 D
Status
TPE2, TPE2 D
Dashboard
TPE3, TPE3 D
Main menus
TPE3, TPE3 D
External setpoint
Power consumption
Energy consumption
Operating hours
Liquid temperature
Analog input 1
Analog input 2
Analog input 3
1)
1)
1)
1)
Pt100/1000 input 1
1)
1)
1)
1)
Pt100/1000 input 2
1)
1)
1)
1)
Analog output
1)
1)
1)
1)
Digital input 2
1)
1)
1)
Digital in/output 3
1)
1)
Digital in/output 4
1)
1)
1)
Fitted modules
Trend data
1)
1)
Controlled from
58
TPE3, TPE3 D
TPE2, TPE2 D
Section
Setpoint
Setpoint
58
Operating mode
Operating mode
58
Control mode
Control mode
59
1)
1)
1)
Settings
Page
1)
Flow limit
FLOWLIMIT
64
65
Temperature influence
Temperature influence
73
Buttons on product
Controller
Operating range
Ramps
Pump number
56
Digital input 1
1)
Sensor value
Page
Actual setpoint
Actual controlled value
Section
Controller settings
68
Operating range
69
Ramps
74
Pump number
74
Radio communication
Sensor type
Analog input 1
Analog input 3
1)
1)
1)
1)
Pt100/1000 input 1
1)
1)
1)
1)
Pt100/1000 input 2
1)
1)
1)
1)
Digital input 1
Digital input 2
1)
1)
1)
74
Sensor type
65
Analog inputs
65
Pt100/1000 inputs
66
Digital inputs
66
Digital inputs/outputs
67
Analog input 2
1)
Digital in/output 3
Digital in/output 4
1)
1)
1)
1)
Predefined setpoint
1)
1)
1)
1)
Predefined setpoints
72
Analog output
1)
1)
1)
1)
Analog output
68
70
Signal relay 1
Signal relay 2
2)
2)
Relay outputs
67
Limit-exceeded function
73
Standstill heating
Service
Store settings
Recall settings
Undo
Pump name
Unit configuration
Limit 1 exceeded
Limit 2 exceeded
Assist
Alarm log
Warning log
"Reset alarm" button
TPE2, TPE2 D
TPE2, TPE2 D
TPE3, TPE3 D
2)
TPE3, TPE3 D
1)
13
Section
Multipump setup
Page
75
57
13
Setpoint
Pump variant
Setpoint
TPE3, TPE3 D
TPE2, TPE2 D
Pump variant
TPE3, TPE3 D
TPE2, TPE2 D
Fig. 44
Operating mode
Pump variant
Operating mode
TPE3, TPE3 D
TPE2, TPE2 D
Min.
Q
Fig. 45
58
Max.
Pump variant
AUTO ADAPT
TPE3, TPE3 D
TPE2, TPE2 D
Control mode
TPE3, TPE3 D
TPE2, TPE2 D
Pump variant
Control mode
fac
HHfac
Hset1
A1
Hauto_min
Hauto_min
A3
Hset2
Q
Note: Not all control modes are available for all pump
variants.
Possible control modes:
AUTOADAPT
FLOWADAPT
Prop. press. (proportional pressure)
Const. pressure (constant pressure)
Const. temp. (constant temperature)
Con. diff. press. (constant differential pressure)
Con. diff. temp. (constant differential temperature)
Const. flow rate (constant flow rate)
Const. level (constant level)
Const. other val. (constant other value)
Const. curve (constant curve).
The setpoint for all control modes, except AUTOADAPT
and FLOWADAPT, can be changed in the "Setpoint"
submenu under "Settings" when the desired control
mode has been selected.
A2
Fig. 46
Pump variant
AUTOADAPT
13
AUTOADAPT
A2:
A3:
Hset1:
Hset2:
Hfac.:
59
13
FLOWADAPT
Proportional pressure
Pump variant
FLOWADAPT
Pump variant
Proportional pressure
TPE3, TPE3 D
TPE2, TPE2 D
TPE3, TPE3 D
TPE2, TPE2 D
90 % Q max
Setting range
fac
QQfac
Fig. 47
Hset
Hset
2
FLOWADAPT
Q
Fig. 48
Proportional pressure
Example
Factory-fitted differential-pressure sensor.
p
Fig. 49
60
Proportional pressure
auto_min
HHauto_min
fac
Hfac
Constant pressure
Constant temperature
Pump variant
Constant pressure
Pump variant
Constant temperature
TPE3, TPE3 D
TPE2, TPE2 D
TPE3, TPE3 D
TPE2, TPE2 D
13
Fig. 50
Constant pressure
Q
Fig. 52
Examples
One external pressure sensor.
Constant temperature
Examples
One external temperature sensor.
Fig. 51
Constant pressure
t
Fig. 53
Constant temperature
61
13
Pump variant
Constant differential
pressure
Pump variant
Constant differential
temperature
TPE3, TPE3 D
TPE2, TPE2 D
TPE3, TPE3 D
TPE2, TPE2 D
Q
Fig. 54
Q
Fig. 56
Examples
One external differential-pressure sensor.
t
t
t
p
p
p
p
p
Fig. 55
62
TPE3, TPE3 D
TPE2, TPE2 D
Fig. 60
Fig. 58
Q set
13
Constant level
Fig. 59
Constant level
Pump variant
Constant level
TPE3, TPE3 D
TPE2, TPE2 D
Fig. 61
Constant level
TPE3, TPE3 D
TPE2, TPE2 D
63
13
Pump variant
Constant curve
Pump variant
FLOWLIMIT
TPE3, TPE3 D
TPE2, TPE2 D
TPE3, TPE3 D
TPE2, TPE2 D
90 % Q max
25 %
Setting range
Constant curve
H [%]
100 %
80 %
Q [m3/h]
64
Fig. 63
FLOWLIMIT
Fig. 62
Q limit
Fig. 64
Q max
FLOWLIMIT
Constant curve
FLOWLIMIT
Pump variant
TPE3, TPE3 D
TPE2, TPE2 D
TPE Series 2000
Analog inputs
Pump variant
Analog inputs
TPE3, TPE3 D
TPE2, TPE2 D
Sensor type
FM 200
(standard)
FM 300
(advanced)
Pump variant
Sensor type
TPE3, TPE3 D
TPE2, TPE2 D
Unit
13
Possible units
Pressure
Pump flow
Liquid temperature
Other parameter
Electrical signal
Select signal type (0.5 - 3.5 V, 0-5 V, 0-10 V, 0-20 mA
or 4-20 mA).
Sensor range, minimum value
Set the minimum value of the connected sensor.
Sensor range, maximum value
Set the maximum value of the connected sensor.
65
13
Pt100/1000 inputs
Function
Pump variant
Pt100/1000 inputs
TPE3, TPE3 D
TPE2, TPE2 D
FM 200
(standard)
FM 300
(advanced)
Function
The Pt100/1000 inputs can be set to these functions:
Not active
Feedback sensor (not applicable for TPE Series
2000)
Ext. setpoint infl.
See section Setpoint influence on page 70.
Other function.
Measured parameter
Select one of the parameters, i.e. the parameter to be
measured in the system.
Digital inputs
Pump variant
Digital inputs
TPE3, TPE3 D
TPE2, TPE2 D
FM 200
(standard)
FM 300
(advanced)
66
Function if output
Not active
External stop
Min.
Max.
External fault
Alarm resetting
Dry running
Accumulated flow*
Predefined setpoint digit 3
This function is only available for TPE2 and TPE Series 1000
pumps with motor sizes from 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1
kW, 4-pole.
Not active
Ready
Alarm
Operation
Pump running
Warning
Limit 1 exceeded*
Limit 2 exceeded*
Relay outputs
Relay outputs
Pump variant
Signal
relay 1
Signal
relay 2
TPE3, TPE3 D
TPE2, TPE2 D
Digital inputs/outputs
Pump variant
Digital inputs/outputs
TPE3, TPE3 D
TPE2, TPE2 D
13
FM 200
(standard)
FM 300
(advanced)
Function if output
Not active
External stop
Min.
Max.
External fault
Alarm resetting
Dry running
Accumulated flow*
Predefined setpoint digit 2
This function is only available for TPE2 and TPE Series 1000
pumps with motor sizes from 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1
kW, 4-pole
This function is only available for TPE2 and TPE Series 1000
pumps with motor sizes from 0.12 to 2.2 kW, 2-pole and 0.12 - 1.1
kW, 4-pole.
Not active
Ready
Alarm
Operation
Pump running
Warning
Limit 1 exceeded*
Limit 2 exceeded*
67
13
Analog output
Controller settings
Pump variant
Analog output
Pump variant
Controller settings
TPE3, TPE3 D
TPE2, TPE2 D
TPE3, TPE3 D
TPE2, TPE2 D
FM 200
(standard)
FM 300
(advanced)
Actual speed
Actual value
Resulting setpoint
Motor load
Motor current
Limit 1 exceeded*
Limit 2 exceeded*
Flow rate.
This function is only available for TPE2 and TPE Series 1000
pumps with motor sizes from 0.12 - 2.2 kW, 2-pole and 0.12 - 1.1
kW, 4-pole.
Kp
Ti
0.5
0.5
0.5
L1 < 5 m: 0.5
L1 > 5 m: 3
L1 > 10 m: 5
L1
S
L1
S
68
13
Temperature control
Heating
system 1)
Cooling
system 2)
Ti
0.5
-0.5
10 + 5L2
t
L2
L2
t
0.5
-0.5
30 + 5L2
1)
Kp
Ti
-0.5
10 + 5L2
L2
Kp
Operating range
Pump variant
Operating range
TPE3, TPE3 D
TPE2, TPE2 D
67 %
t
t
L2
Kp
Ti
0.5
0.5
Kp
Ti
0.5
0.5
0.1
0.5
Kp
Ti
-2.5
100
2.5
100
24 %
12 %
0%
Constant-pressure control
Fig. 65
Flow control
Operating range
Level control
L
69
13
[bar]
Upper value
Setpoint
Actual
setpoint
1.2
Lower value
100
Actual input
External
100 setpoint
signal
signal [%]
Fig. 66
70
Not active
Linear function
Linear with Stop
Linear with Min.
Inverse function
Inverse with Stop
Inverse with Min.
Influence table
Influence table with Stop
at Min.
Influence table with Stop
at Max.
TPE Series
2000
TPE Series
1000
Type of setpoint
influence
TPE3, TPE3 D
TPE2, TPE2 D
External setpoint
influence
TPE2
Pump variant
TPE3
Setpoint influence
Inverse function
The setpoint is influenced inversely from 0 to 100 %.
See fig. 69.
Setpoint influence [%]
100
0
20
Fig. 67
40
60
80
100
External input
[%]
20
Linear function
Fig. 69
40
60
80
100
External input
[%]
100
13
Inverse function
100
100
0
40
60
80
100
External
input [%]
TM05 6283 4612
20
Normal
0
40
60
80
100
External
input [%]
Normal
Min. or
Stop
Fig. 68
Min. or
Stop
TM05 6281 4612
20
Fig. 70
71
13
100
0
20
60
80
100
External input
[%]
100
Influence table
0
20
Fig. 73
80
100
Normal
Min. or
Stop
Fig. 72
72
External
input [%]
TM05 6285 4612
60
100 External
input [%]
Predefined setpoints
Pump variant
Predefined setpoints
TPE3, TPE3 D
TPE2, TPE2 D
40
80
Min. or
Stop
20
60
Normal
100
40
Fig. 71
40
Influence table
The setpoint is influenced by a curve made out of
two to eight points. There will be a straight line
between the points and a horizontal line before the
first point and after the last point.
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
Setpoint
Normal setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
1
2
3
4
5
6
7
Temperature influence
Selection of Tmax.
Pump variant
Temperature
influence
TPE3, TPE3 D
TPE2, TPE2 D
Monitoring functions
Limit-exceeded function
100 %
30 %
20
Fig. 74
50
actual
TTactual
80 T [C]
HHactual
actual
Temperature influence
Pump variant
Limit-exceeded
function
TPE3, TPE3 D
TPE2, TPE2 D
13
73
13
Speed
Maximum
TPE3, TPE3 D
TPE2, TPE2 D
Minimum
Initial ramp
Final ramp
Ramp-up
Ramp-down
TPE3, TPE3 D
TPE2, TPE2 D
Fig. 75
Communication
Pump number
Pump variant
Pump number
TPE3, TPE3 D
TPE2, TPE2 D
Pump variant
Time
Special functions
Pump number
TPE3, TPE3 D
TPE2, TPE2 D
General settings
Language
Pump variant
Language
TPE3, TPE3 D
TPE2, TPE2 D
74
Units
Alternating operation
Enable/disable settings
In this display, you can disable the possibility of
making settings for protective reasons.
To unlock the pump and allow settings, press and
simultaneously for at least 5 seconds.
Delete history
In this menu, you can delete the following historic data:
Delete work log.
Delete heat energy data.
Delete energy consumption.
Define Home display
In this menu, you can select whether the "Home"
display should show various user-defined parameters
or a graphical illustration of a performance curve with
the actual duty point of the pump.
Display settings
In this menu you can adjust the display brightness and
define whether or not the display should turn off if no
buttons have been touched for a period of time.
Store actual settings
In this menu you can store the actual settings for later
use.
Recall stored settings
In this menu, you can recall the last stored settings
that the pump will then use.
Run startup guide
The startup guide guides you through the general
settings of the pump.
Assist
Multipump setup
Pump variant
Multipump setup
TPE3, TPE3 D
TPE2, TPE2 D
Backup operation
One pump is operating continuously. The backup
pump is operated at intervals to prevent seizing up. If
the duty pump stops due to a fault, the backup pump
starts automatically.
Pump system:
Twin-head pump.
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
13
User interfaces for TPE pumps
Cascade operation
Cascade operation ensures that the pump
performance is automatically adapted to the
consumption by switching pumps on or off. The system
thus runs as energy-efficiently as possible with a
constant pressure and a limited number of pumps.
When a TPE3 D twin-head pump runs in
constant-pressure control mode, the second pump
head starts at 90 % and stops at 50 % performance.
All pumps in operation run at equal speed. Pump
changeover is automatic and depends on energy,
operating hours and fault.
Pump system:
TPE3 D twin-head pump.
Two to four single-head pumps connected in
parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
Set the control mode to "Const. pressure", Const.
diff. pressure or "Const. curve".
75
13
Grundfos Eye
Fig. 76
Grundfos Eye
Grundfos Eye
Indication
Description
No lights on.
Power off.
Motor not running.
Power on.
Motor running.
Power on.
Motor not running.
Warning.
Motor stopped.
Alarm.
Motor stopped.
76
13
Grundfos Eye
Operation
Pump
running
Ready
Alarm
Warning
Power off.
Operating
mode
Off
NO NC
NO NC
NO NC
NO NC
NO NC
Normal, Min.
or Max.
Green, rotating
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
Manual
Green, rotating
Stop
Green, steady
NO NC
NO NC
NO NC
NO NC
NO NC
Normal, Min.
or Max.
Yellow, rotating
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
Manual
Yellow, rotating
NO NC
Stop
Yellow, steady
NO NC
NO NC
NO NC
NO NC
NO NC
Normal, Min.
or Max.
Red, rotating
NO NC
NO NC
NO NC
NO NC
NO NC
Manual
Red, rotating
NO NC
NO NC
NO NC
NO NC
NO NC
Stop
Red, flashing
NO NC
NO NC
NO NC
NO NC
NO NC
77
13
Fig. 77
78
TM05 85922513
The functions of the two indicator lights and the signal relay are as shown in the following table:
Indicator lights
Fault
(red)
Operation
(green)
Off
Off
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
NO NC
Flashing
NO NC
Off
C
NO NC
NO NC
NO NC
NO NC
Permanently on Permanently on
C
Permanently on
Description
Permanently on
Pump running
Permanently on
C
Off
Ready
Off
Operating
13
NO NC
NO NC
NO NC
NO NC
Flashing
C
NO NC
NO NC
NO NC
NO NC
79
14
Setpoint
Operating mode
Control mode
Function
description
Auto
page 58
Normal
Normal
Normal
Normal
Normal
page 58
AutoAdapt
Constant
curve
Constant
curve
Constant
curve
page 59
Flow limit
1)
page 64
Temperature influence
page 65
page 73
Kp
1.0
0.5
0.5
Ti
8.0
0.5
0.5
1)
Proportional Proportional
pressure
pressure
1)
Buttons on product
Comments
Normal
1)
1)
Settings
Function is enabled.
Function is disabled.
Function is not available.
TPE2, TPE2 D
TPE3, TPE3 D
Controller
page 68
Operating range
Min.
25 %
25 %
25 %
25 %
25 %
25 %
Max.
100 %
100 %
110 %
110 %
110 %
110 %
Ramps
page 74
Pump number
page 74
Radio communication
page 74
Sensor type
page 65
page 65
Analog input 1
Analog input 2
Analog input 3 1)
Pt100/1000 input 2 1)
Digital input 1
Digital input 2 1)
Digital in/output 3
Digital in/output 4 1)
setpoint 1)
page 66
page 66
page 67
Analog output 1)
page 68
Alarm
page 70
Signal relay 1
Alarm
Signal relay 2
Operation 2)
Operation 2)
Limit 1 exceeded
Limit 2 exceeded
Standstill heating
Grundfos
Grundfos
Grundfos
Grundfos
SI units
SI units
SI units
SI units
SI units
SI units
Predefined
80
page 69
page 72
page 67
page 73
15. Communication
Communication with TPE2, TPE2
D, TPE3, TPE3 D, TPE, TPED
pumps
Remote control
The operator can monitor and change control modes
and settings of the pump with Grundfos GO. See
section Grundfos GO on page 55.
15
Communication
CIM
CIM
CIM
CIM
CIM
CIM
CIM
CIM
CIM
100:
150:
200:
250:
270:
300:
500:
500:
050:
100:
150:
200:
250:
270:
300:
500:
500:
LonWorks
PROFIBUS DP
Modbus RTU
GSM
GRM
BACnet MS/TP
Modbus TCP
PROFINET IO
GENIbus
LonWorks
PROFIBUS DP
Modbus RTU
GSM/GPRS
GRM
BACnet MS/TP
Modbus TCP
PROFINET
Fig. 78
CIU
CIU
CIU
CIU
CIU
CIU
CIU
CIU
81
16
Affinity equations
Hn
Hx
H
n n 2
n
------- ------
H
n x
x
nn
nx
Eta
Q
Qx
H
H
[m]
[m]
Qn
nx
n
------- 1
nn
Max. curve
Q
P
Fig. 79
Q [m/h]
[m3h]
Q
Qx
Qn
Px
Pn
n n 3
------- -----
Px
n x
nn
Pn
Min. curve
82
nn
Q
n------ -----n
Q
x
x
nx
Fig. 80
Affinity equations
Legend
Hn
Hx
Qn
Qx
nn
nx
n
x
Pn
Px
TPE3 D
TPE
Built-in parallel
operation function
TPE3
TPE
TPE2 D
Built-in
alternation/standby
function
TP
TPE2
Parallel-operation
control possibilities
Control MPC
17
Control of pumps in parallel
Available.
Available on request.
Alternation/standby function
The alternation/standby function is activated from
factory and "Alternating" mode is selected as default.
See pages and 34 and 31.
83
17
Control of pumps in parallel
84
18
Grundfos CUE
GrA 4404
Fig. 81
Grundfos CUE
Fig. 82
x
x
x
x
x
200-240
200-240
380-500
525-600
525-690
x
x
x
x
x
200-240
200-240
380-500
525-600
525-690
Motor [kW]
1.1 - 7.5
0.75 - 45
0.55 - 250
0.75 - 7.5
11-250
External communication
Grundfos CUE can communicate with LonWorks,
PROFIBUS, Modbus, BACnet or GSM/GPRS via a
Grundfos CIU.
85
19
Motor data
Motor range
kW
2-pole
Mounting designation
Pump type
TP
TP
TP
TP
Series
Series
Series
Series
100
200
300
400
Relative humidity:
Enclosure class:
Insulation class:
Ambient temperature:
86
Mains-operated motors
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
90.0
110
132
160
200
250
315
355
400
500
560
630
1-phase MG,
3-phases
Siemens
4-pole
6-pole
Electronically
speed-controlled
motors
2-pole
4-pole
1-phase MG,
3-phases
Siemens
MGE*
MGE*
MG
MG
Siemens
MGE
MGE
Siemens
Siemens
* Permanent-magnet motors
MG and MGE are Grundfos motor brands.
Siemens is a sourced high-quality motor brand.
The grey-shaded areas indicate non-available motors.
1 x 220-230/240 V
3 x 380-415/660-690 V
Cos 1/1
[%]
n [min-1]
IStart
-----------I 1/1
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
n [min-1]
IStart
-----------I 1/1
1.05
1.0
65
2,800-2,840
3.2 - 3.6
2.2
4.45
0.89 - 0.87
85.9
2890-2910
8.5 - 9.5
1.34
0.94
62
2895
4.3
3.0
6.3
0.87 - 0.82
87.1
2900-2920
8.4 - 9.2
0.25
2.05 / 2
0.99
58
2800
4.0
7.9
0.87
88.1
2920-2940
10 - 11
0.37
2.95 / 2.7
0.99
60
2770
2.8
5.5
11.0
0.87 - 0.82
89.2
2920-2940
10.8 - 11.8
0.55
4 / 3.65
0.99
66
2750
2.8
0.75
5.1 / 4.75
0.99
69
2780
3.0
7.5
14.4 - 14.0 /
8.3 - 8.1
0.88 - 0.82
90.4
2910-2920
7.8 - 9.1
1.1
7.4 / 6.7
0.98 - 0.99
2770
3.9 / 3.9
11.0
91.2
2940-2950
6.6 - 7.8
9.9 / 8.9
0.98 - 0.99
72-74
2750-2740
3.9 / 3.9
20.8 - 19.8 /
12.0 - 11.8
0.88 - 0.84
1.5
15.0
28.0 - 26.0 /
16.2 - 15.6
0.89 - 0.87
91.9
2930-2950
6.6 - 7.8
18.5
34.0 - 31.0 /
19.6 - 18.8
0.90 - 0.89
92.4
2930-2950
7.1 - 8.5
22.0
39.5 / 22.8
0.90
92.7
2950
8.3
Motor
[kW]
I1/1 [A]
0.12
0.18
3 x 220-240/380-415 V
IStart
-----------I 1/1
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
0.12
0.59 / 0.34
0.8 - 0.72
71
2800-2850
0.18
0.9 / 0.52
0.79 - 0.71
67
2800-2850
4.5
0.25
1.18 / 0.68
0.81 - 0.72
73
2800-2850
4.0 - 4.4
0.37
1.74 / 1
0.8 - 0.7
78.5
2850-2880
4.9 - 5.3
0.55
2.5 / 1.44
0.8 - 0.7
80
2830-2850
1.9
30.0
54.0 - 31.0
0.9
93.3
2955
6.6
66.0 - 38.0
0.9
93.7
2955
6.7
[min-1]
4.2 - 4.6
I1/1 [A]
Cos 1/1
3 x 380-420/660-725 V
[%]
n [min-1]
IStart
-----------I 1/1
0.75
3.3 / 1.9
0.81 - 0.71
80.7
2840-2870
5.8 - 6.2
37.0
1.1
4.35 - 2.5
0.83 - 0.76
82.7
2840-2870
4.5 - 5.0
45.0
78.0 - 45.0
0.9
94.0
2960
6.9
1.5
5.45 / 3.15
0.87 - 0.82
84.2
2890-2910
8.5 - 9.3
55.0
95.0 - 55.0
0.9
94.3
2975
6.7
2.2
7.70 / 4.45
0.89 - 0.87
85.9
2890-2910
8.5 - 9.5
75.0
128.0 - 74.0
0.9
94.7
2975
6.8
152.0 - 88.0
0.9
95.0
2975
7.2
3.0
11.0 / 6.3
0.87 - 0.82
87.1
2900-2920
8.4 - 9.2
90.0
4.0
13.6 / 7.9
0.87
88.1
2920-2940
10 - 11.1
110.0
184.0 - 106.0
0.9
95.2
2980
7.1
5.5
19.0 - 11.0
0.87 - 0.82
89.2
2920-2940
10.8 - 11.8
132.0
220.0 - 128.0
0.9
95.4
2980
7.2
7.5
25.0 - 24.2 /
14.4 - 14.0
0.88 - 0.82
90.4
2910-2920
7.8 - 9.1
160.0
265.0 - 154.0
0.9
95.6
2980
7.8
11.0
36.0 - 34.5 /
20.8 - 19.8
0.88 - 0.84
91.2
2940-2950
6.6 - 7.8
15.0
48.5 - 45.0 /
28.0 - 26.0
0.89 - 0.87
91.9
2930-2950
6.6 - 7.8
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
18.5
59.0 - 53.5 /
34.0 - 31.0
0.90 - 0.89
92.4
2930-2950
7.1 - 8.5
0.12
0.99
0.99
68.5 / 39.5
0.90
0.18
1.62
0.97
0.25
2.14
0.37
22.0
92.7
2950
8.3
3 x 220-240/380-420 V
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
n [min-1]
IStart
-----------I 1/1
30.0
94.0 - 54.0
0.9
93.3
2955
6.6
37.0
114.0 - 66.0
0.9
93.7
2955
6.7
45.0
136.0 - 78.0
0.9
94.0
2960
6.9
55.0
166.0 - 95.0
0.9
94.3
2975
6.7
75.0
220.0 - 128.0
0.9
94.7
2975
6.8
Motor data
19
1 x 220-230/240 V
n [min-1]
IStart
-----------I 1/1
53.1
1434
2.58
54
1350-1370
2.0
0.97
57
1350-1370
2.2
2.85
0.97
62
1350-1370
2.4
0.55
0.97
66
1350-1370
2.6
0.75
5.45
0.96
71
1390-1410
3.2
1.1
0.96
75
1420-1430
3.9
87
19
Motor data
IStart
-----------I 1/1
Motor
[kW]
I1/1 [A]
1380
3.2
18.5
35.0 - 20.6
0.8
1400-1420
4.0 - 4.4
22.0
41.0 - 24.0
0.8
1400-1420
4.0 - 4.4
30.0
55.0 - 32.0
77
1390-1410
4.3 - 4.7
37.0
0.76 - 0.71
82.5
1440-1450
6.6 - 7.2
4.85 / 2.0
0.71 - 0.64
84.1
1450-1460
8.2 - 9.0
1.5
6.15 - 6.3 /
3.55 - 3.65
0.75 - 0.68
85.3
1450-1460
7.3 - 7.9
2.2
8.5 / 4.9
0.79 - 0.73
86.7
1450
Motor
[kW]
I1/1 [A]
0.12
0.78 / 0.45
0.67
54
0.25
1.48 / 0.85
0.75 - 0.65
69
0.37
1.9 / 1.1
0.77 - 0.67
71
0.55
2.6 / 1.5
0.79 - 0.7
0.75
3.3 / 1.9
1.1
Cos 1/1
[%]
n [min-1]
3 x 380-420/660-725 V
n [min-1]
IStart
-----------I 1/1
92.6
1470
6.9
93.0
1470
6.8
0.8
93.6
1470
6.9
66.0 - 38.5
0.9
93.9
1480
6.4
45.0
80.0 - 46.5
0.9
94.2
1480
6.4
55.0
96.0 - 56.0
0.9
94.6
1480
6.8
75.0
134.0 - 77.0
0.9
95.0
1485
6.9
90.0
158.0 - 91.0
0.9
95.2
1485
7.2
6.0 - 6.6
110.0
192.0 - 112.0
0.9
95.4
1490
6.8
3.0
11.0 / 6.3
0.82 - 0.76
87.7
1440-1450
7.0 - 7.7
132.0
230.0 - 134.0
0.9
95.6
1490
7.3
4.0
16.2 / 9.3
0.75 - 0.68
88.6
1460
7.9 - 8.7
160.0
275.0 - 162.0
0.9
95.8
1490
7.3
5.5
19.0 / 11.0
0.86 - 0.80
89.6
1460
7.6
200.0
340.0 - 198.0
0.9
96.0
1490
7.4
7.5
26.0 - 24.6 /
14.9 - 14.2
0.86 - 0.82
90.4
1460
6.8 - 7.8
250.0
430.0 - 250.0
0.9
96.0
1490
7.7
36.5 - 35.5 /
21.2 - 20.4
315.0
550.0 - 320.0
0.9
96.0
1490
7.9
0.86 - 0.81
355.0
630.0 - 365.0
0.9
96.1
1490
6.5
400.0
690.0 / 400.0
0.87
1488
500.0
850.0 / 490.0
0.88
1488
560.0
950.0 / 550.0
0.88
1492
630.0
1060.0 / 610.0
0.88
1492
11.0
15.0
50.0 - 48.5 /
29.0 - 28.0
0.86 - 0.82
91.4
92.1
1470-1470
1460-1470
7.1 - 8.1
7.6 - 8.7
3 x 220-240/380-420 V
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
n [min-1]
IStart
-----------I 1/1
18.5
60.0 - 34.5
0.8
92.4
1765
6.2
22.0
71.0 - 41.0
0.8
92.4
1765
6.0
30.0
95.5 - 55.0
0.9
93.0
1765
6.1
88
3 x 220-240/380-415 V
3 x 220-240/380-415 V
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
n [min-1]
IStart
-----------I 1/1
1.5
6.6 - 5.9 /
3.8 - 3.4
0.79
86.5
1160
5.6
2.2
9.17 - 8.3 /
5.3 - 4.8
0.79
87.5
1160
6.8
IStart
-----------I 1/1
3.0
12.0 - 11.0 /
7.0 - 6.4
0.78
87.5
1165
6.9
4.0
15.7 - 14.2 /
9.1 - 8.2
0.79
87.5
1160
6.5
3 x 380-415/660-690 V
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
2.2
1.9
0.76 - 0.71
82.5
1440-1450
6.6 - 7.2
3.0
6.3
0.82 - 0.76
87.7
1440-1450
7.0 - 7.7
4.0
9.3
0.75 - 0.68
88.6
1460
7.9 - 8.7
5.5
21.0 - 19.3 /
12.2 - 11.0
0.81
89.5
1180
6.6
5.5
11.0 - 11.0 /
6.35 - 6.35
0.86 - 0.80
89.6
1460
7.0 - 7.6
7.5
27.7 - 25.4 /
16.0 - 14.5
0.82
89.5
1165
6.3
7.5
14.9 - 14.2 /
8.6 - 8.4
0.86 - 0.82
90.4
1460
6.8 - 7.8
11.0
21.2 - 20.4 /
12.2 - 12.0
0.86 - 0.81
91.4
1460-1470
7.1 - 8.1
15.0
29.0 - 28.0 /
16.8 - 16.4
0.86 - 0.82
92.1
1460-1470
7.6 - 8.7
[min-1]
3 x 380-415/660-690 V
Motor
[kW]
I1/1 [A]
Cos 1/1
[%]
n [min-1]
IStart
-----------I 1/1
2.2
5.3 - 4.8 /
3.0 - 2.9
0.75
84.3
970
6.8
3.0
7.0 - 6.4 /
4.05 - 3.9
0.76
85.6
975
6.9
4.0
9.1 - 8.2 /
5.2 - 4.95
0.77
86.8
970
6.5
5.5
12.2 - 11.0 /
7.0 - 6.7
0.78
88
970
6.6
7.5
16.0 - 14.5 /
9.2 - 8.8
0.80
89.1
975
6.3
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
32-80
32-120
32-150
32-180
32-200
40-80
40-120
40-150
40-180
40-200
40-240
50-60
50-80
50-120
50-150
50-180
50-200
65-60
65-80
65-120
65-150
65-180
80-40
80-120
80-150
100-40
100-120
100-150
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
32-80
32-120
32-150
32-180
32-200
40-80
40-120
40-150
40-180
40-200
40-240
50-60
50-80
50-120
50-150
50-180
50-200
50-240
65-60
65-80
65-120
65-150
65-180
65-200
80-40
80-120
80-150
80-180
100-40
100-120
100-150
100-180
Motor [kW]
I1/1 [A]
Motor [kW]
I1/1 [A]
0.12
1.65 - 1.40
0.25
0.25
0.37
0.55
0.75
0.25
0.37
0.55
0.75
1.1
1.5
0.37
0.37
0.55
0.75
1.1
1.5
0.37
0.55
0.75
1.1
1.5
0.25
1.1
1.5
0.25
1.1
1.5
1.56
1.56
2.29
3.15
4.17
1.56
2.17
3.04
4.17
5.97
8.00
2.17
2.17
3.04
4.1
5.97
8.00
2.17
3.04
4.10
5.97
8.00
1.46
5.88
7.97
1.46
5.88
7.97
0.18
1.65 - 1.40
0.25
1.65 - 1.40
0.37
2.40 - 2.00
0.55
3.40 - 2.85
0.75
4.50 - 3.80
Motor [kW]
I1/1 [A]
0.25
0.25
0.37
0.55
0.75
0.25
0.37
0.55
0.75
1.1
1.5
0.37
0.37
0.55
0.75
1.1
1.5
2.2
0.37
0.55
0.75
1.1
1.5
2.2
0.25
1.1
1.5
2.2
0.25
1.1
1.5
2.2
0.88
0.88
1.09
1.34
1.68
0.88
1.09
1.34
1.68
2.26
2.96
1.04
1.04
1.34
1.68
2.26
2.96
4.22
1.04
1.34
1.68
2.15
2.96
4.22
0.82
2.15
2.82
4.03
0.82
2.15
2.82
4.03
Motor [kW]
I1/1 [A]
0.12
1.70 - 1.45
0.18
1.70 - 1.45
0.25
1.70 - 1.45
0.37
2.40 - 2.10
0.55
3.40 - 2.90
0.75
4.60 - 3.80
1.1
6.55 - 5.45
1.5
8.90 - 7.45
Motor [kW]
I1/1 [A]
0.12
0.85 - 0.80
0.18
0.85 - 0.80
0.25
0.85 - 0.80
0.37
1.00 - 0.90
0.55
1.20 - 1.10
0.75
1.55 - 1.40
1.1
2.20 - 1.90
Motor [kW]
I1/1 [A]
0.12
0.85 - 0.80
0.18
0.85 - 0.80
0.25
0.85 - 0.80
0.37
1.00 - 0.90
0.55
1.30 - 1.10
0.75
1.55 - 1.30
1.1
2.15 - 1.80
1.5
2.90 - 2.40
2.2
4.15 - 3.40
Motor data
19
Motor [kW]
I1/1 [A]
0.12
3.0 - 2.5
0.25
3.0 - 2.5
0.37
2.7 - 2.5
0.55
3.9 - 3.6
0.75
5.1 - 4.7
1.1
7.1 - 6.6
89
19
Motor data
I1/1 [A]
3.0
6.2 - 5.0
4.0
8.1 - 6.6
5.5
11.0 - 8.8
7.5
14.8 - 11.6
11.0
22.5 - 18.8
15.0
30 - 26.0
18.5
37 - 31.0
22.0
43.5 - 35.0
90
Motor [kW]
I1/1 [A]
1.5
3.3 - 2.9
2.2
4.6 - 3.8
3.0
6.2 - 5.0
4.0
8.1 - 6.6
5.5
11 - 9.0
7.5
15.0 - 12.0
11.0
22.0 - 17.8
15.0
30.0 - 25.4
18.5
37.0 - 30.0
20. Installation
Mechanical installation
Fig. 83
Installation
20
Fig. 84
PN 16
PN 25
P2 [kW]
11
15
18.5
22
11
15
18.5
22
11
15
18.5
22
11
11
15
18.5
22
11
15
18.5
22
15
18.5
22
18.5
22
30
37
45
55
75
15
18.5
22
30
45
55
37
50 Hz
TP, TPE 65-460/2
TP, TPE 65-550/2
TP, TPE 65-660/2
TP, TPE 65-720/2
TP, TPE 80-330/2
TP, TPE 80-400/2
TP, TPE 80-520/2
TP, TPE 80-570/2
TP, TPE 100-250/2
TP, TPE 100-310/2
TP, TPE 100-360/2
TP, TPE 100-390/2
TP, TPE 80-340/4
TP, TPE 100-250/4
TP, TPE 100-330/4
TP, TPE 100-370/4
TP 100-410/4
TP, TPE 125-190/4
TP, TPE 125-230/4
TP, TPE 125-300/4
TP 125-340/4
TP, TPE 150-200/4
TP, TPE 150-220/4
TP 150-250/4
TP, TPE 150-260/4
TP 150-280/4
TP 150-340/4
TP 150-390/4
TP 150-450/4
TP 150-520/4
TP 150-660/4
TP, TPE 200-160/4
TP, TPE 200-190/4
TP 200-200/4
TP 200-240/4
TP 200-270/4
TP 200-320/4
TP 200-330/4
91
20
Installation
Pump type
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
200-360/4
200-400/4
200-410/4
200-470/4
300-190/4
300-220/4
300-250/4
300-290/4
300-390/4
300-420/4
300-430/4
300-500/4
300-550/4
350-230/4
350-280/4
350-310/4
350-360/4
350-420/4
350-480/4
350-530/4
350-650/4
350-780/4
PN 16
PN 25
P2 [kW]
45
55
75
75
30
37
45
55
75
90
110
132
160
55
75
90
110
132
160
200
250
315
Horizontal pipe
L
Fig. 85
Vertical pipe
Fig. 86
Fig. 87
Drain hole
92
Cooling
Pump type
TP 200-290/4
Installation
20
50 Hz
Expansion joint
Fig. 89
Vibration dampers
Fig. 90
Concrete foundation
Foundation of TP pump
Concrete foundation
Install the pump on a plane and rigid concrete
foundation. This is the optimum solution for vibration
dampening. As a rule of thumb, the weight of a
concrete foundation should be 1.5 times the pump
weight.
93
20
Installation
Fig. 91
Pump mass
[kg]
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
1300
1350
1400
1450
1500
1550
1600
1650
1700
94
DN 200
Y (height)
[mm]
Z (length)
[mm]
X (width)
[mm]
280
310
330
360
375
390
410
420
440
450
460
470
480
490
500
510
520
530
540
550
560
560
570
580
590
600
600
610
620
620
630
635
565
620
670
710
750
780
810
840
870
900
920
940
970
990
1010
1030
1050
1060
1080
1100
1100
1130
1150
1160
1180
1190
1200
1220
1230
1250
1250
1270
565
620
670
710
750
780
810
840
870
900
920
940
970
990
1010
1030
1050
1060
1080
1100
1100
1130
1150
1160
1180
1190
1200
1220
1230
1250
1250
1270
Pump mass
[kg]
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
3000
3400
3800
4200
4600
5000
5400
DN 300 /
DN 350 /
DN 400
Y (height)
[mm]
Z (length)
[mm]
X (width)
[mm]
450
450
450
500
500
500
550
550
550
600
600
680
760
840
920
1000
1080
1400
1400
1400
1600
1600
1600
1600
1700
1800
1800
2000
2000
2000
2000
2000
2000
2000
800
1000
1200
1200
1350
1500
1600
1700
1800
1800
2000
2000
2000
2000
2000
2000
2000
Vibration dampers
To prevent the transmission of vibrations to buildings,
we recommend that you isolate the pump foundation
from building parts by means of vibration dampers.
The selection of the right vibration damper requires the
following data:
forces transmitted through the damper
motor speed considering speed control, if any
required dampening in % (suggested value is 70 %).
The right damper varies from installation to installation,
and a wrong damper may increase the vibration level.
Vibration dampers must therefore be sized by the
supplier.
If you install the pump on a foundation with vibration
dampers, always fit expansion joints on the pump
flanges. This is important to prevent the pump from
"hanging" in the flanges.
20
Expansion joints
Fig. 92
Installation
Fig. 94
3
3Stellung
o'clock
Fig. 95
6
6Stellung
o'clock
9
9Stellung
o'clock
Standard
Stellung
12
12
o'clock
Expansion joints
Fig. 93
95
20
B4
Fig. 96
Installation
Electrical installation
B4
96
P2 [kW]
TPED 32-250/2
1.5
TPED 32-320/2
2.2
TPED 32-380/2
3.0
TPED 32-460/2
4.0
TPED 32-580/2
5.5
TPED 40-300/2
3.0
TPED 40-360/2
4.0
TPED 40-430/2
5.5
TPED 40-530/2
7.5
TPED 40-630/2
11
TPED 50-290/2
3.0
TPED 50-360/2
4.0
TPED 50-430/2
5.5
TPED 50-420/2
7.5
TPED 50-540/2
11
TPED 50-630/2
15
TPED 50-710/2
15
TPED 50-830/2
18.5
TPED 50-900/2
22
TPED 65-210/2
3.0
TPED 65-250/2
4.0
TPED 65-340/2
5.5
TPED 65-410/2
7.5
TPED 65-460/2
11
TPED 65-550/2
15
TPED 65-660/2
18.5
TPED 65-720/2
22
TPED 80-210/2
4.0
TPED 80-240/2
5.5
TPED 80-330/2
11
TPED 80-400/2
15
TPED 80-520/2
18.5
TPED 80-570/2
22
TPED 100-120/2
2.2
TPED 100-60/4
1.1
Mains-operated motors
The operating voltage and frequency are marked on
the pump nameplate. Make sure that the motor is
suitable for the power supply on which it will be used.
Single-phase standard motors incorporate a thermal
switch and require no additional motor protection.
Three-phase motors must be connected to a motor
starter.
Motors of 3 kW and up incorporate thermistors (PTC).
The thermistors are designed according to DIN 44082.
The electrical connection must be carried out as
shown in the diagram inside the terminal box cover.
The motors of twin-head pumps are to be connected
separately.
Frequency converter operation
Motors types Siemens, MG 71 and MG 80 for supply
voltages up to and including 440 V (see motor
nameplate) must be protected against voltage peaks
higher than 650 V between the supply terminals.
Grundfos motors:
You can connect all three-phase Grundfos motors from
frame size 90 and up to a frequency converter.
The connection of a frequency converter often have
the effect that the motor insulation system is loaded
more and that the motor is more noisy than during
normal operation. In addition, large motors are loaded
by bearing currents caused by the frequency
converter.
In the case of frequency converter operation, consider
the following:
In 2-pole motors from 45 kW, 4-pole motors from 30
kW and 6-pole motors from 22 kW, one of the motor
bearings must be electrically isolated to prevent
damaging currents from passing through the motor
bearings.
In the case of noise-critical applications, reduce the
motor noise by fitting a dU/dt filter between the motor
and the frequency converter. In particularly
noise-critical applications, we recommend that you fit a
sinusoidal filter.
The length of the cable between the motor and
frequency converter affects the motor load. Therefore
check that the cable length meets the specifications
laid down by the frequency converter supplier.
For supply voltages between 500 and 690 V, fit either a
dU/dt filter to reduce voltage peaks or use a motor with
reinforced insulation.
For supply voltages of 690 V, use a motor with
reinforced insulation, and fit a dU/dt filter.
For other motor makes than Grundfos, contact
Grundfos or the motor manufacturer.
Min.
[A]
Max.
[A]
0.12 - 0.75
1.1 - 1.5
6
10
10
16
Min.
[A]
Max.
[A]
0.12 - 1.1
1.5 - 2.2
6
6
6
10
Leakage current
[mA]
< 3.5
<5
Inputs/outputs
Ground reference (GND)
All voltages refer to GND.
All currents return to GND.
21
MGE motors
97
21
MGE motors
EN 61800-3.
Residential areas, unlimited distribution,
corresponding to CISPR 11, class B, group 1.
Industrial areas, unlimited distribution, corresponding
to CISPR 11, class A, group 1.
Contact Grundfos for further information.
Temperature range:
Minimum -30 C (88 / 882 ).
Maximum 180 C (168 / 1685 ).
Measurement tolerance: 1.5 C.
Measurement resolution: < 0.3 C.
Automatic range detection (Pt100 or Pt1000): Yes.
Sensor fault alarm: Yes.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Use Pt100 for short wires.
Use Pt1000 for long wires.
4000
98
Enclosure class
Motor
[kW]
Max. speed
stated on
nameplate
[min-1]
2000
0.12 - 0.75
4000
2000
1.1
1.5
4000
2.2
4000
Speed
[min-1]
1500
2000
3000
4000
1500
2000
3000
4000
3000
4000
3000
4000
3-phase
motors
38
42
53
58
38
42
53
58
38
42
53
58
57
64
57
64
53
58
57
64
Additional protection
Pump size
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
TPE2/TPE3
32-80
32-120
32-150
32-180
32-200
40-80
40-120
40-150
40-180
40-200
40-240
50-60
50-80
50-120
50-150
50-180
50-200
50-240
65-60
65-80
65-120
65-150
65-180
65-200
80-40
80-120
80-150
80-180
100-40
100-120
100-150
100-180
58
58
65
66
66
54
58
58
63
65
66
52
56
58
58
63
64
66
50
54
57
58
62
62
42
55
62
64
42
55
62
64
Motor protection
The motor requires no external motor protection. The
motor incorporates thermal protection against slow
overloading and blocking.
Single-phase motors
If the motor is connected to an electric installation
where an earth leakage circuit breaker (ELCB) or
ground fault circuit interrupter (GFCI) is used as
additional protection, this circuit breaker or interrupter
must be marked with the following symbol:
MGE motors
21
ELCB
(GFCI)
Start/stop of pump
The number of starts and stops via the mains voltage
must not exceed 4 times per hour.
When the pump is switched on via the mains, it starts
after approximately 5 seconds.
If you want a higher number of starts and stops, use
the input for external start/stop when starting/stopping
the pump.
When the pump is started/stopped via an external
on/off switch, it starts immediately.
99
21
Single-phase supply:
MGE motors
Wiring diagrams
Fig. 97
L1
L1
L2
L2
L3
L3
PE
Fig. 98
Three-phase supply:
Connection terminals
The descriptions and terminal overviews in this section
apply to both single-phase and three-phase motors.
The number of terminals depends on the functional
module (FM). You can identify the fitted module on the
motor nameplate. See fig. 99.
INPUT
:
U in
A I 1/1 :
Made in Hungary
DK - 8850 Bjerringbro, Denmark
:
f in
I SF Ampp:
VARIANT
Hp PB :
rpm FM :
HMI :
HMI:
CIM :
OUTPUT
VARIANT
P2
P
Hp PB :
:
rpm FM :
V n max:
:
HMI :
Hz Eff
CIM :
A
Xxxxxxxxxxx
P.C. :
Serial no :
Env.Type
Env.Ty
ype
p :
TEFC
SF :
CL:
kg
g Tamb :
F PF:
E.P. Motor
Type
Typ
ype :
P.N. :
DE :
NDE :
Wg
gt :
Wgt
Fig. 99
100
Terminal
NC
C1
NO
NC
C2
NO
NC
Type
Function
Normally closed
contact
Common
Normally open
contact
Signal relay 1
(LIVE or SELV)
Normally closed
contact
Common
Normally open
contact
Signal relay 2
(SELV only)
10
DI3/OC1
AI1
2
5
6
A
Y
B
DI1
+5 V
GND
GENIbus, A
GENIbus, Y
GENIbus, B
3
15
8
26
23
25
24
GND
+24 V
+24 V
+5 V
GND
GDS TX
GDS RX
AI2
C1
NO
NC
C2
+24 V*
+24 V*/5 V*
+24 V*/5 V*
10
+5 V*
DI3/OC1
AI1
DI1
+5 V
GND
GENIbus A
GENIbus Y
GENIbus B
GND
15
+24 V
+24 V
26
+5 V
23
GND
25
GDS TX
24
GDS RX
AI2
+24 V*
+24 V*
GND
+24 V*
NO
DI
+24 V*
OC
MGE motors
21
101
21
MGE motors
102
Terminal
NC
Type
Function
NC
C1
NO
Signal relay 1
(LIVE or SELV)
NC
C2
NO
Signal relay 2
(SELV only)
18
GND
11
DI4/OC2
19
17
Pt100/1000 input 2
Pt100/1000 input 1
12
AO
GND
14
AI3
DI2
21
20
GND
22
10
DI3/OC1
AI1
DI1
+5 V
6
A
Y
B
GND
GENIbus, A
GENIbus, Y
GENIbus, B
3
15
8
GND
+24 V
+24 V
26
+5 V
23
GND
25
GDS TX
24
GDS RX
AI2
C1
NO
NC
C2
NO
+24 V*
+24 V*
+24 V*
+24 V*/5 V*
+24 V*/5 V*
+5 V*
11
DI4/OC2
19
Pt100/1000
17
Pt100/1000
12
AO
GND
14
AI3
DI2
21
LiqTec
20
GND
22
LiqTec
10
GND
DI3/OC1
AI1
DI1
+5 V
GND
GENIbus A
GENIbus Y
GENIbus B
GND
15
+24 V
+24 V
26
+5 V
23
GND
25
GDS TX
24
GDS RX
AI2
+24 V*
+5 V*
DI
GND
+24 V*
OC
+24 V*/5 V*
+24 V*
18
DI
+24 V*
OC
+24 V*
MGE motors
21
Ground
Digital input/output,
configurable.
Open collector: Max. 24 V
resistive or inductive.
Pt100/1000 sensor input
Pt100/1000 sensor input
Analog output:
0-20 mA / 4-20 mA
0-10 V
Ground
Analog input:
0-20 mA / 4-20 mA
0-10 V
Digital input, configurable
LiqTec sensor input
(white conductor)
Ground
(brown and black
conductors)
LiqTec sensor input
(blue conductor)
Digital input/output,
configurable.
Open collector: Max. 24 V
resistive or inductive.
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V
Digital input, configurable
Supply to potentiometer and
sensor
Ground
GENIbus, A (+)
GENIbus, GND
GENIbus, B (-)
Ground
Supply
Supply
Supply to potentiometer and
sensor
Ground
Grundfos Digital Sensor
output
Grundfos Digital Sensor
input
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V
103
21
MGE motors
Motor size
[kW]
Max. fuse
[A]
1.5 - 5.5
7.5
11
15
18.5
22
16
32
26
36
43
51
Leakage current
[mA]
1.5 - 3.0
4.0 - 5.5
< 3.5
<5
< 10
> 10
Input/output
Start/stop
External potential-free switch.
Voltage: 5 VDC.
Current: < 5 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Digital input
External potential-free switch.
Voltage: 5 VDC.
Current: < 5 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
104
Potentiometer
0-10 VDC, 10 k (via internal voltage supply).
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 100 m.
Voltage signal
0-10 VDC, Ri > 50 k.
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Current signal
DC 0-20 mA / 4-20 mA, Ri = 175 .
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Sensor signals
Backup fuse
Setpoint signals
Voltage signal
0-10 VDC, Ri > 50 k (via internal voltage supply).
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Current signal
DC 0-20 mA / 4-20 mA, Ri = 175 .
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Power supply to sensor
+24 VDC, max. 40 mA.
Signal output
Potential-free changeover contact.
Maximum contact load: 250 VAC, 2 A.
Minimum contact load: 5 VDC, 10 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Bus input
Grundfos GENIbus protocol, RS-485.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Emission:
The motors may be installed in residential areas (first
environment), unrestricted distribution, corresponding to
CISPR11, group 1, class B.
Immunity:
The motors fulfil the requirements for both the first and
second environment.
Emission:
The motors are category C3, corresponding to CISPR11,
group 2, class A, and may be installed in industrial areas
(second environment).
If fitted with an external Grundfos EMC filter, the motors are
category C2, corresponding to CISPR11, group 1, class A,
and may be installed in residential areas (first environment).
When the motors are installed in residential
areas, supplementary measures may be
Note:
required as the motors may cause radio
interference.
Immunity:
The motors fulfil the requirements for both the first and
second environment.
3.0
4.0
5.5
7.5
11
Enclosure class
Standard: IP55 (IEC34-5).
15
Insulation class
F (IEC 85).
18.5
Ambient temperature
During operation: -20 to 40 C.
During storage/transport:
22
Sound pressure
level
[dB(A)]
1400-1500
1700-1800
1400-1500
1700-1800
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
2800-3000
3400-3600
53
57
50
52
55
60
65
70
58
63
70
75
52
56
75
80
54
58
65
69
54
59
65
70
54
59
65
70
65
69
69
74
73
78
MGE motors
21
105
21
MGE motors
Motor protection
The motor requires no external motor protection. The
motor incorporates thermal protection against slow
overloading and blocking.
Additional protection
If the motor is connected to an electric installation
where an earth leakage circuit breaker is used as
additional protection, this circuit breaker must fulfil the
following:
It is suitable for handling leakage currents and
cutting-in in case of short pulse-shaped leakage.
It trips out when alternating fault currents and fault
currents with DC content, i.e. pulsating DC and
smooth DC fault currents, occur.
For these pumps, use an earth leakage circuit breaker
type B.
This circuit breaker must be marked with the following
symbols:
ELCB
Start/stop of pump
The number of starts and stops via the mains voltage
must not exceed 4 times per hour.
When the pump is switched on via the mains, it will
start after approximately 5 seconds.
If a higher number of starts and stops is desired, use
the input for external start/stop when starting/stopping
the pump.
When the pump is started/stopped via an external
on/off switch, it starts immediately.
106
21
Group 3
Group 2
MGE motors
L1 L2 L3
External switch
Max. 16/32 A
L1
L1
ELCB
L3
PE
L2
L3
L2
Other connections
4-20 mA
1/0
1 9 8 7
B Y A
STOP
6:
5:
4:
3:
2:
RUN
0/4-20 mA
0-10 V
10K
GND (frame)
+10 V
Setpoint input
GND (frame)
Start/stop
0/4-20 mA
Group 1
1: Digital input
9: GND (frame)
8: +24 V
7: Sensor input
B: RS-485B
Y: Screen
A: RS-485A
0-10 V
6 5 4 3 2
NC C NO
0/4-20 mA
1:
9:
8:
7:
4-20 mA
0/1
1 9 8 7
Digital input
GND (frame)
+24 V
Sensor input
B: RS-485B
Y: Screen
A: RS-485A
STOP
6:
5:
4:
3:
2:
RUN
0/4-20 mA
0-10 V
10K
GND (frame)
+10 V
Setpoint input
GND (frame)
Start/stop
6 5 4 3 2
Group 1
B YA
L1 L2 L3
0-10 V
Group 3
Group 2
Group 4
107
21
Group 3
Group 2
External switch
Max. 26/51 A
L1
L2
L1
ELCB
L3
PE
L2
L3
MGE motors
Other connections
6:
5:
4:
3:
2:
GND (frame)
+10 V
Setpoint input
GND (frame)
Start/stop
6:
5:
4:
3:
2:
GND (frame)
+10 V
Setpoint input
GND (frame)
Start/stop
Group 1
1: Digital input
9: GND (frame)
8: +24 V
7: Sensor input
B: RS-485B
Y: Screen
A: RS-485A
108
Group 2
Group 1: Inputs
Group 1
1: Digital input
9: GND (frame)
8: +24 V
7: Sensor input
B: RS-485B
Y: Screen
A: RS-485A
EMC
22. EMC
EMC and proper installation
General information
What is EMC?
ElectoMagnetic Compatibility is an electric or
electronic device's ability to function in a given
electromagnetic environment without disturbing the
surroundings and without being disturbed by other
devices in the surroundings. EMC is normally split into
emission and immunity.
22
Emission
Emission is defined as the electric or electromagnetic
noise emitted by a device during operation and which
can reduce the function of other devices or disturb
various radio communications, including radio/TV.
Immunity
Immunity deals with a device's ability to function in
spite of the presence of electric or electromagnetic
noise, such as sparking noise from contactors or
high-frequency fields from various transmitters, mobile
phones, etc.
109
23
Flange dimensions
PN 6 and PN 10 flanges
EN 1092-2 PN 6 (0.6 MPa)
D1
S
D2
D3
40
50
65
80
100
32
40
50
65
80
100
125
150
200
250
D1
32
40
50
65
80
100
32
40
50
65
80
100
125
150
200
250
D2
90
100
110
130
150
170
100
110
125
145
160
180
210
240
295
350
D3
120
130
140
160
190
210
140
150
165
185
200
220
250
285
340
395
S 4 x 14 4 x 14 4 x 14 4 x 14 4 x 19 4 x 19
4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 8 x 23 12 x 23
PN 16 and PN 25 flanges
EN 1092-2 PN 16 (1.6 MPa)
D1
32
D2
D3
40
50
65
80
100
200
100
125
150
200
250
300
350
D1
32
40
50
65
80
100
125
150
200
100
125
150
200
250
300
350
100
110
125
145
160
180
210
240
295
190
220
250
310
370
430
490
D3
140
150
165
185
200
220
250
285
340
235
270
300
360
425
485
555
S 4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 12 x 23
D1
110
125
D2
PN 40 flanges
D2
D3
400
500
D1
400
500
D2
585
670
D3
660
755
16 x 39
20 x 42
8 x 23 8 x 28 8 x 28 12 x 28 12 x 31 16 x 31 16 x 34
24
Curve charts
TP, TPE 32
-580/2
50
50 Hz
55
-460/2
45
40
-380/2
35
-320/2
30
-250/2
25
-200/2
20
15
10
0
12
16
20
24
P2
[kW]
6
Q [m/h]
-580/2
-460/2
4
3
-380/2
-320/2
-250/2
-200/2
1
0
0
NPSH
[m]
12
16
20
24
Q [m/h]
16
12
8
4
0
0
Eta
[%]
60
12
16
-200/2
20
-250/2
24
Q [m/h]
-320/2
55
-380/2
-580/2
50
-460/2
45
40
35
30
4
12
16
20
24
Q [m/h]
Q [l/s]
v [m/s]
111
24
Curve charts
112
Curve conditions
The guidelines below apply to the curves shown on the
following pages:
Tolerances to ISO 9906:2012 Grade 3B.
The curves apply to the performance of
single-head three-phase pumps. For other pump
versions, please see the exact curves in Grundfos
Product Center. See page 231. For other pump
versions, the performance may differ for the
following reasons:
The valve in twin-head pumps may cause losses.
Single-phase motors run at lower speed.
Note: Grundfos does not recommend continuous
parallel operation of twin-head pumps (except
TPE2 D, TPE3 D) due to the increased flow in the
pump. A too high flow results in noisy operation,
increased wear of the impeller due to cavitation,
etc.
QH curves of the individual single-head pumps are
shown with expected speed of a three-phase
mains-operated motor. For further information, see
the tables of technical data on the following pages.
The performance of the single-phase motor is
slightly reduced. Please refer to Grundfos Product
Center for the exact single-phase curves. See page
231.
Curves of TPE Series 1000 pumps and TPE Series
2000 pumps are shown as nominal curves (100 %
curves) only. Please refer to Grundfos Product
Center for the exact curves. See page 231.
Measurements have been made with airless water
at a temperature of 20 C.
The curves apply to a kinematic viscosity of = 1
mm2/s (1 cSt).
Due to the risk of overheating, the pump must not
run constantly below the minimum flow rate
indicated by the bold curves.
If the pumped liquid density and/or viscosity are
higher than those of water, it may be necessary to
use a motor with a higher performance.
24
Curve charts
113
25
DN 32
PN 6, 10, 16
73(
73(
+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
4>PK@
4>OV@
114
(WD
>@
3
>N:@
73('
73('
Y>PV@
25
DN 32
PN 6, 10, 16
Technical data
TPE2, TPE3 32
TPE2, TPE3
TPE2 D, TPE3 D
P2
PN
Tmin;Tmax
D1
AC
AD
AE
AF
P
B1
B2
B3
B4
1~/3~
1~/3~
1~/3~
1~/3~
1~/3~
1~
3~
C1
C5
C6
C7
C8
L1
H1
H2
H3
M
1~
3~
kW
[C]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
-80
-120
-150
-180
-200
0.25
PN 6/10/16
[-25;120]
32
122/122
155/158
106/134
106/134
165
73/210
73/209
260
-/317
-/337
-/263
-/50
-/97
-/90
-/130
220
65/68
159
439/442
479/482
M12
0.25
PN 6/10/16
[-25;120]
32
122/122
155/158
106/134
106/134
165
73/210
73/209
260
-/317
-/337
-/263
-/50
-/97
-/90
-/130
220
65/68
159
439/442
479/482
M12
0.37
PN 6/10/16
[-25;120]
32
122/122
155/158
106/134
106/134
165
73/210
73/209
260
-/317
-/337
-/263
-/50
-/97
-/90
-/130
220
65/68
159
439/442
479/482
M12
0.55
PN 6/10/16
[-25;120]
32
122/122
155/158
106/134
106/134
165
73/210
73/209
260
-/317
-/337
-/263
-/50
-/97
-/90
-/130
220
65/68
159
439/442
479/482
M12
0.75
PN 6/10/16
[-25;120]
32
122/122
155/158
106/134
106/134
165
73/210
73/209
260
-/317
-/337
-/263
-/50
-/97
-/90
-/130
220
65/68
159
439/442
479/482
M12
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
115
25
DN 40
PN 6, 10, 16
+
>P@
73(
73(
+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
116
(WD
>@
4>PK@
136+
>P@
3
>N:@
73('
73('
4>PK@
4>OV@
Y>PV@
25
DN 40
PN 6, 10, 16
Technical data
TPE2, TPE3 40
TPE2, TPE3
TPE2 D, TPE3 D
P2
1~/3~
PN
Tmin;Tmax
D1
AC
1~/3~
AD
1~/3~
AE
1~/3~
AF
1~/3~
P
B1
B2
B3
1~
B4
3~
C1
C5
C6
C7
C8
L1
H1
H2
1~
H3
3~
M
kW
[C]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
-80
-120
-150
-180
-200
-240
0.25
PN 6/10/16
[-25;120]
40
122/122
155/158
106/134
106/134
165
72/218
82/220
260
-/317
-/337
-/260
-/75
-/58
-/155
-/130
250
65/69
162
442/446
482/486
M12
0.37
PN 6/10/16
[-25;120]
40
122/122
155/158
106/134
106/134
165
72/218
82/220
260
-/317
-/337
-/260
-/75
-/58
-/155
-/130
250
65/69
162
442/446
482/486
M12
0.55
PN 6/10/16
[-25;120]
40
122/122
155/158
106/134
106/134
165
72/218
82/220
260
-/317
-/337
-/260
-/75
-/58
-/155
-/130
250
65/69
162
442/446
482/486
M12
0.75
PN 6/10/16
[-25;120]
40
122/122
155/158
106/134
106/134
165
72/218
82/220
260
-/317
-/337
-/260
-/75
-/58
-/155
-/130
250
65/69
162
442/446
482/486
M12
1.1
PN 6/10/16
[-25;120]
40
122/122
155/158
106/134
106/134
165
72/218
82/220
260
-/317
-/337
-/260
-/75
-/58
-/155
-/130
250
65/69
162
442/446
482/486
M12
1.5
PN 6/10/16
[-25;120]
40
122/122
155/158
106/134
106/134
165
72/218
82/220
260
-/317
-/337
-/260
-/75
-/58
-/155
-/130
250
65/69
162
462/466
502/506
M12
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
117
25
DN 50
PN 6, 10, 16
+
>P@
73(
73(
+
>P@
136+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
4>PK@
118
(WD
>@
3
>N:@
73('
73('
4>PK@
4>OV@
Y>PV@
25
DN 50
PN 6, 10, 16
Technical data
TPE2, TPE3 50
-60
-80
-120
-150
-180
-200
-240
TPE2, TPE3
TPE2 D, TPE3
P2
PN
Tmin;Tmax
D1
AC
AD
AE
AF
P
B1
B2
B3
0.37
PN 6/10/16
[-25;120]
50
122/122
155/158
106/134
106/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
449/451
489/491
M12
0.37
PN 6/10/16
[-25;120]
50
122/122
155/158
106/134
106/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
449/451
489/491
M12
0.55
PN 6/10/16
[-25;120]
50
122/122
155/158
106/134
106/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
449/451
489/491
M12
0.75
PN 6/10/16
[-25;120]
50
122/122
155/158
106/134
106/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
449/451
489/491
M12
1.1
PN 6/10/16
[-25;120]
50
122/122
155/158
106/134
106/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
449/451
489/491
M12
1.5
PN 6/10/16
[-25;120]
50
122/122
155/158
106/134
106/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
469/471
509/511
M12
2.2
PN 6/10/16
[-25;120]
50
122/122
155/158
-/134
-/134
165
75/223
91/227
260
-/317
-/337
-/260
-/75
-/175
-/75
-/130
280
72/75
162
509/511
M12
B4
D
1~/3~
1~/3~
1~/3~
1~/3~
1~/3~
1~
3~
C1
C5
C6
C7
C8
L1
H1
H2
H3
M
1~
3~
kW
[C]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
119
25
DN 65
PN 6, 10, 16
+
>P@
73(
73(
+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
4>PK@
136+
>P@
(WD
>@
73('
73('
3
>N:@
120
4>PK@
4>OV@
Y>PV@
25
DN 65
PN 6, 10, 16
Technical data
TPE2, TPE3 65
TPE2, TPE3
TPE2 D, TPE3 D
P2
1~/3~
PN
Tmin;Tmax
D1
AC
1~/3~
AD
1~/3~
AE
1~/3~
AF
1~/3~
P
B1
B2
B3
1~
B4
3~
C1
C5
C6
C7
C8
L1
H1
H2
1~
H3
3~
M
kW
[C]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
-60
-80
-120
-150
-180
-200
0.37
PN 6/10/16
[-25;120]
65
122/122
155/158
106/134
106/134
165
81/228
102/240
260
-/317
-/337
-/260
-/92
-/218
-/92
-/130
340
74/78
169
458/462
498/502
M12
0.55
PN 6/10/16
[-25;120]
65
122/122
155/158
106/134
106/134
165
81/228
102/240
260
-/317
-/337
-/260
-/92
-/218
-/92
-/130
340
74/78
169
458/462
498/502
M12
0.75
PN 6/10/16
[-25;120]
65
122/122
155/158
106/134
106/134
165
81/228
102/240
260
-/317
-/337
-/260
-/92
-/218
-/92
-/130
340
74/78
169
458/462
498/502
M12
1.1
PN 6/10/16
[-25;120]
65
122/122
155/158
106/134
106/134
165
81/228
102/240
260
-/317
-/337
-/260
-/92
-/218
-/92
-/130
340
74/78
169
458/462
498/502
M12
1.5
PN 6/10/16
[-25;120]
65
122/122
155/158
106/134
106/134
165
81/228
102/240
260
-/317
-/337
-/260
-/92
-/218
-/92
-/130
340
74/78
169
478/482
518/522
M12
2.2
PN 6/10/16
[-25;120]
65
122/122
155/158
-/134
-/134
165
81/228
102/240
260
-/317
-/337
-/260
-/92
-/218
-/92
-/130
340
74/78
169
518/522
M12
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
121
25
DN 80
PN 6, 10, 16
+
>P@
+
>P@
73(
73(
4>PK@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
122
(WD
>@
3
>N:@
73('
73('
4>OV@
Y>PV@
25
DN 80
PN 6, 10, 16
Technical data
TPE2, TPE3 80
TPE2, TPE3
TPE2 D, TPE3 D
P2
PN
Tmin;Tmax
D1
AC
AD
AE
AF
P
B1
B2
B3
B4
1~/3~
1~/3~
1~/3~
1~/3~
1~/3~
1~
3~
C1
C5
C6
C7
C8
L1
H1
H2
H3
M
1~
3~
kW
[C]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
-40
-120
-150
-180
0.25
PN 6/10/16
[-25;120]
80
122/122
155/158
106/134
106/134
165
97/244
123/254
260
-/317
-/337
-/260
-/102
-/218
-/102
-/130
360
94/97
176
485/488
525/528
M12
1.1
PN 6/10/16
[-25;120]
80
122/122
155/158
106/134
106/134
165
97/244
123/254
260
-/317
-/337
-/260
-/102
-/218
-/102
-/130
360
94/97
176
485/488
525/528
M12
1.5
PN 6/10/16
[-25;120]
80
122/122
155/158
106/134
106/134
165
97/244
123/254
260
-/317
-/337
-/260
-/102
-/218
-/102
-/130
360
94/97
176
505/508
545/548
M12
2.2
PN 6/10/16
[-25;120]
80
122/122
155/158
-/134
-/134
165
97/244
123/254
260
-/317
-/337
-/260
-/102
-/218
-/102
-/130
360
94/97
176
545/548
M12
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
123
25
DN 100
PN 6, 10, 16
+
>P@
73(
73(
+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
(WD
>@
124
4>PK@
4>PK@
136+
>P@
3
>N:@
73('
73('
4>OV@
Y>PV@
25
DN 100
PN 6, 10, 16
Technical data
TPE2, TPE3 100
-40
-120
-150
-180
TPE2, TPE3
TPE2 D, TPE3 D
P2
PN
Tmin;Tmax
D1
AC
AD
AE
AF
P
B1
B2
B3
0.25
PN 6/10/16
[-25;120]
100
122/122
155/158
106/134
106/134
165
98/ 252
125/ 265
270
-/322
-/342
-/270
-/147
-/243
-/147
-/135
450
102/104
189
506/508
546/548
M12
1.1
PN 6/10/16
[-25;120]
100
122/122
155/158
106/134
106/134
165
98/ 252
125/ 265
270
-/322
-/342
-/270
-/147
-/243
-/147
-/135
450
102/104
189
506/508
546/548
M12
1.5
PN 6/10/16
[-25;120]
100
122/122
155/158
106/134
106/134
165
98/ 252
125/ 265
270
-/322
-/342
-/270
-/147
-/243
-/147
-/135
450
102/104
189
526/528
566/568
M12
2.2
PN 6/10/16
[-25;120]
100
122/122
155/158
-/134
-/134
165
98/ 252
125/ 265
270
-/322
-/342
-/270
-/147
-/243
-/147
-/135
450
102/104
189
566/568
M12
B4
1~/3~
1~/3~
1~/3~
1~/3~
1~/3~
1~
3~
C1
C5
C6
C7
C8
L1
H1
H2
H3
M
1~
3~
kW
[C]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
125
25
G 1 1/2
2-pole, PN 6, 10, 16, 25
7373(
5
+]
5
5
3
>N:@
4>PK@
5
5
5
136+
>P@
4>PK@
5
5
5
(WD
>@
4>PK@
5
5
5
126
4>PK@
4>OV@
Y>PV@
25
G 1 1/2
2-pole, PN 6, 10, 16, 25
Technical data
TP 25
-50/2 R
-80/2 R
TPD
-90/2 R
-
TPE
TPED
Series
100
100
100
1~ TP
63
63
71
3~ TP
63
63
71
1~ TPE
71
71
71
3~ TPE
IEC size
P2
1~/3~ TP
PN
Tmin;Tmax
[C]
G
AC
AD
1~/3~ TP
0.18/-
0.37/-
10
10
10
G 1 1/2
G 1 1/2
[mm] 141/124
141/124
141/141
0.12/-
122/-
[mm] 133/101
122/-
122/-
133/101
133/109
158/-
158/-
158/-
AE
106/-
106/-
106/-
AF
106/-
106/-
106/-
B1
[mm]
54
54
60
B2
[mm]
62
62
68
L1
[mm]
180
180
180
H1
[mm]
46
46
48
H2
[mm]
120
120
120
357/345
358/358
380/-
381/-
H3
1~/3~ TP
[mm] 357/345
380/-
127
25
G2
2-pole, PN 6, 10, 16, 25
7373(
5
+]
5
5
3
>N:@
4>PK@
5
5
5
136+
>P@
4>PK@
5
5
5
(WD
>@
4>PK@
5 5
5
128
4>PK@
4>OV@
Y>PV@
25
G2
2-pole, PN 6, 10, 16, 25
Technical data
TP 32
-50/2 R
-80/2 R
TPD
-90/2 R
-
TPE
TPED
Series
100
100
100
1~ TP
63
63
71
3~ TP
63
63
71
1~ TPE
71
71
71
3~ TPE
IEC size
P2
1~/3~ TP
PN
Tmin;Tmax
[C]
G
AC
AD
0.12/-
0.25/-
0.37/-
10
10
10
1~/3~ TP
[mm] 141/124
122/-
[mm] 133/101
G2
G2
141/124
141/141
122/-
122/-
133/101
133/109
158/-
158/-
158/-
AE
106/-
106/-
106/-
AF
106/-
106/-
106/-
B1
[mm]
54
54
60
B2
[mm]
62
62
68
L1
[mm]
180
180
180
H1
[mm]
48
48
47
H2
[mm]
120
120
120
359/347
357/357
382/-
380/-
H3
1~/3~ TP
[mm] 359/347
382/-
129
25
DN 32
2-pole, PN 6, 10, 16, 25
+
>P@
7373(
+]
3
>N:@
+]
7373(
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
(WD
>@
4>PK@
4>OV@
Y>PV@
TM02 5016 2115
Note: All curves apply to single-head pumps. For further information, see page 112.
130
4>PK@
4>OV@
Y>PV@
(WD
>@
25
DN 32
2-pole, PN 6, 10, 16, 25
Technical data
TP 32
-60/2
-120/2
-150/2
-180/2
-230/2
-200/2
-250/2
-320/2
-380/2
-460/2
-580/2
TPD
TPE
TPED
300
Series
IEC size
200
200
200
200
200
300
300
300
300
300
1~ TP
71
71
71
80
80
3~ TP
63
71
71
71
80
80
90
90
100
112
132
1~ TPE
3~ TPE
90
90
100
112
132
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
-/1.1
-/1.5
-/2.2
-/3
-/4
-/5.5
-/1.5
-/2.2
-/3
-/4
-/5.5
PN 6/10
PN 6/10
PN 6/10
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
32
1~/3~ TP
[mm] 124/124
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 101/101
32
32
32
32
32
32
32
32
32
32
141/142
141/141
141/141
141/141
-/141
-/178
-/178
-/198
-/220
-/220
-/122
-/122
-/198
-/220
-/220
133/133
133/109
133/109
133/109
-/109
-/110
-/110
-/120
-/134
-/134
1~/3~ TPE
[mm]
-/158
-/158
-/177
-/188
-/188
AE
1~/3~ TPE
[mm]
-/130
-/130
-/132
-/145
-/145
AF
1~/3~ TPE
[mm]
-/130
-/130
-/132
-/145
-/145
[mm]
90/90
200
200
200
250
250
300
B1
[mm]
75/176
75/180
102/222
102/222
102/222
B2
[mm]
75/176
75/180
102/222
102/222
102/222
B3
[mm]
200
200
240
240
240
276
276
276
276
355
355
B4
[mm]
-/338
-/334
-/344
-/403
-/403
C1
[mm]
80/200
80/200
80/240
80/240
80/240
C5
[mm]
110/52
110/52
140/82
140/82
140/82
170/45
170/45
170/45
170/45
220/46
220/46
C6
[mm]
103
103
103
103
103
175
175
175
175
175
175
L1
[mm]
220
220
280
280
280
340
340
340
340
440
440
H1
[mm]
68
68
79
79
79
100
100
100
100
100
100
H2
[mm] 140/139
126
125
125
137
154
154
154
183
184
223
1~/3~ TP
[mm] 387/386
385/385
395/395
447/395
447/447
-/505
-/535
-/575
-/618
-/656
-/714
1~/3~ TPE
[mm]
-/488
-/528
-/618
-/656
-/714
[mm]
M12
M12
M12
M12
M12
M16
M16
M16
M16
M16
M16
H3
H4
M
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
131
25
DN 40
2-pole, PN 6, 10, 16, 25
+
>P@
7373(
+]
+
>P@
3
>N:@
4>PK@
3
>N:@
4>PK@
4>PK@
136+
>P@
136+
>P@
4>PK@
(WD
>@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
4>PK@
TM02 5018 2115
4>PK@
4>PK@
132
+]
(WD
>@
7373(
4>PK@
4>OV@
Y>PV@
25
DN 40
2-pole, PN 6, 10, 16, 25
Technical data
TP 40
-50/2
-60/2
-80/2
-90/2
-120/2
-180/2
-190/2
-230/2
-270/2
TPD
TPE
TPED
Series
100
200
100
100
200
200
200
200
200
1~ TP
63
71
63
71
71
80
80
90
90
3~ TP
63
71
63
71
71
71
80
80
90
1~ TPE
71
71
71
71
71
71
80
80
3~ TPE
90
90
90
1.1/1.1
1.5/1.5
IEC size
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
PN 6/10
PN 6/10
PN 6/10
PN 6/10
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
1~/3~ TP
[mm] 141/124
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/101
40
40
40
40
40
40
141/141
141/124
141/141
141/141
141/141
141/141
133/109
133/101
133/109
133/109
133/109
133/109
40
40
178/141 178/178
-
139/109 139/110
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
B1
[mm]
75/-
75/180
75/-
75/-
75/180
100/-
102/222
102/222 102/222
B2
[mm]
75/-
75/180
75/-
75/-
75/180
100/-
102/222
102/222 102/222
B3
[mm]
200
200
240
C1
[mm]
80/200
80/200
80/-
120/240
120/240 120/240
240
240
C5
[mm]
125/45
125/45
125/-
160/95
160/95
C6
[mm]
125
125
125
125
125
L1
[mm]
250
250
250
250
250
250
320
320
320
H1
[mm]
67
67
67
62
67
68
68
68
68
H2
[mm]
120
129
120
120
129
131
141
141
151
H3
H4
M
160/95
1~/3~ TP
[mm] 378/366
387/366
378/366
373/373
387/387
442/390
439/439
1~/3~ TPE
[mm]
499/510 539/500
-
[mm]
M12
M12
M12
M12
M12
M12
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
133
25
DN 40
2-pole, PN 6, 10, 16, 25
TP 40-XX/2
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
134
25
DN 40
2-pole, PN 6, 10, 16, 25
Technical data
TP 40
-240/2
-300/2
-360/2
-430/2
-530/2
-630/2
TPD
TPE
TPED
300
Series
IEC size
300
300
300
300
300
1~ TP
3~ TP
90
100
112
132
132
160
1~ TPE
3~ TPE
100
112
132
132
160
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
AD
-/3
-/4
-/5.5
-/7.5
-/11.0
-/3
-/4
-/5.5
-/7.5
-/11.0
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
D1
AC
-/2.2
[mm]
40
40
40
40
40
40
1~/3~ TP
[mm]
-/178
-/198
-/220
-/220
-/260
-/314
1~/3~ TPE
[mm]
-/198
-/220
-/220
-/260
-/314
1~/3~ TP
[mm]
-/110
-/120
-/134
-/134
-/159
-/204
1~/3~ TPE
[mm]
-/177
-/188
-/188
-/213
-/308
AE
1~/3~ TPE
[mm]
-/132
-/145
-/145
-/145
-/210
AF
1~/3~ TPE
[mm]
-/132
-/145
-/145
-/145
-/210
[mm]
200
250
250
300
300
350
B1
B2
B3
[mm]
290
290
290
355
355
355
B4
[mm]
-/351
-/370
-/403
-/414
-/523
C1
C5
[mm]
170/45
170/45
170/45
C6
[mm]
175
175
175
175
175
L1
[mm]
340
340
340
440
440
440
H1
[mm]
100
100
100
110
110
110
H2
H3
H4
M
1~/3~ TP
1~/3~ TPE
[mm]
166
194
194
223
223
253
[mm]
-/587
-/629
-/666
-/724
-/724
-/832
[mm]
-/629
-/666
-/724
-/724
-/832
[mm]
35
M16
M16
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
135
25
DN 50
2-pole, PN 6, 10, 16, 25
TP 50-XX/2
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
(WD
>@
Note: All curves apply to single-head pumps. For further information, see page 112.
136
25
DN 50
2-pole, PN 6, 10, 16, 25
Technical data
TP 50
-60/2
-120/2
-180/2
-160/2
-190/2
-240/2
-290/2
TPD
TPE
TPED
300
Series
IEC size
200
200
200
300
300
300
1~ TP
71
80
80
3~ TP
71
80
80
80
90
90
100
1~ TPE
3~ TPE
100
-/3
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
-/1.1
-/1.5
-/2.2
-/3
PN 6/10
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
PN 16
1~/3~ TP
[mm] 141/141
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/133
50
50
50
50
50
50
141/141
141/141
-/141
-/178
-/178
-/198
-/198
133/133
133/109
-/109
-/110
-/110
-/120
1~/3~ TPE
[mm]
-/177
AE
1~/3~ TPE
[mm]
-/132
AF
1~/3~ TPE
[mm]
-/132
200
200
200
250
[mm] 105/105
120/120
B1
[mm]
90/177
100/221
100/225
B2
[mm]
75/188
100/221
100/225
B3
[mm]
200
240
240
270
270
270
270
B4
[mm]
-/335
C1
[mm] 120/200
120/240
120/240
C5
[mm]
140/60
140/60
140/60
170/60
170/60
170/60
170/60
C6
[mm]
125
126
126
175
175
175
175
L1
[mm]
280
280
280
340
340
340
340
H1
[mm]
75
75/61
75
115
115
115
115
H2
[mm]
137
135/141
135
152
152
152
180
H3
H4
M
1~/3~ TP
[mm] 403/403
441/441
441/441
-/518
-/548
-/588
-/630
1~/3~ TPE
[mm]
-/630
[mm]
M12
M12
M12
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
137
25
DN 50
2-pole, PN 6, 10, 16, 25
TP 50-XX/2
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
138
25
DN 50
2-pole, PN 6, 10, 16, 25
Technical data
TP 50
-360/2
-430/2
-420/2
-540/2
-630/2
-710/2
-830/2
-900/2
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
300
300
300
1~ TP
3~ TP
112
132
132
160
161
160
160
180
1~ TPE
3~ TPE
112
132
132
160
161
160
160
180
1~/3~ TP [kW]
-/4
-/5.5
-/7.5
-/11
-/15
-/15
-/18.5
-/22
1~/3~ TPE
-/4
-/5.5
-/7.5
-/11
-/15
-/15
-/18.5
-/22
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
[kW]
PN
Tmin;Tmax
D1
[mm]
50
50
50
50
50
50
50
50
1~/3~ TP
[mm]
-/220
-/220
-/260
-/314
-/314
-/314
-/314
-/314
1~/3~ TPE
[mm]
-/220
-/220
-/260
-/314
-/314
-/314
-/314
-/314
1~/3~ TP
[mm]
-/134
-/134
-/159
-/204
-/204
-/204
-/204
-/204
1~/3~ TPE
[mm]
-/188
-/188
-/213
-/308
-/308
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/145
-/145
-/210
-/210
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/145
-/145
-/210
-/210
-/210
-/210
-/210
[mm]
250
300
300
350
350
350
350
350
B1
AC
AD
B2
B3
[mm]
320
320
420
420
420
420
420
420
B4
[mm]
-/385
-/385
-/385
-/385
-/385
-/555
-/555
-/555
C1
C5
[mm]
170/52
170/52
C6
[mm]
175
175
175
175
175
175
175
175
L1
[mm]
340
340
440
440
440
440
440
440
H1
[mm]
115
115
115
115
115
115
115
115
H2
[mm]
189
228
227
257
257
264
264
264
[mm]
-/676
-/734
-/721
-/843
-/843
-/850
-/894
-/894
[mm]
-/676
-/734
-/721
-/843
-/843
-/850
-/894
-/920
[mm]
35
35
35
35
35
M16
M16
M16
M16
M16
M16
M16
M16
H3
H4
M
1~/3~ TP
1~/3~ TPE
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
139
25
DN 65
2-pole, PN 6, 10, 16, 25
TP 65-XX/2
+
>P@
3
>N:@
7373(
+]
4>PK@
4>PK@
136+
>P@
(WD
>@
4>PK@
4>OV@
Y>PV@
4>PK@
Note: All curves apply to single-head pumps. For further information, see page 112.
140
25
DN 65
2-pole, PN 6, 10, 16, 25
Technical data
TP 65
-60/2
-120/2
-180/2
-170/2
-210/2
-250/2
TPD
TPE
TPED
300
Series
IEC size
200
200
200
300
300
1~ TP
80
90
90
3~ TP
71
80
90
90
100
112
1~ TPE
3~ TPE
100
112
1.1/1.1
1.5/1.5
-/2.2
-/3
-/4
-/3
-/4
PN 16
PN 16
PN 16
P2
1~/3~ TPE
[kW]
PN
PN 6/10
Tmin;Tmax
[C]
D1
[mm]
AC
AD
PN 6/10 PN 6/10
1~/3~ TP
[mm] 141/141
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/109
65
65
178/141 178/178
-
139/109 139/110
65
65
65
-/178
-/198
-/220
-/198
-/220
-/110
-/120
-/134
1~/3~ TPE
[mm]
-/177
-/188
AE
1~/3~ TPE
[mm]
-/132
-/145
AF
1~/3~ TPE
[mm]
-/132
-/145
[mm]
200
250
250
B1
[mm]
93/195
B2
[mm]
93/210
B3
[mm]
240
240
240
320
320
320
B4
[mm]
-/366
-/385
C1
[mm] 120/240
C5
[mm]
170/63
170/63
170/63
180/65
180/65
180/65
C6
[mm]
153
153
153
175
175
175
L1
[mm]
340
340
340
360
360
360
H1
[mm]
82
82
82
105
105
105
H2
[mm]
145
144
154
164
193
193
H3
H4
M
1~/3~ TP
[mm] 468/418
-/590
-/633
-/670
1~/3~ TPE
[mm]
517/532 557/507
-
-/633
-/670
[mm]
M12
M12
M12
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
141
25
DN 65
2-pole, PN 6, 10, 16, 25
TP 65-XX/2
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
(WD
>@
Note: All curves apply to single-head pumps. For further information, see page 112.
142
25
DN 65
2-pole, PN 6, 10, 16, 25
Technical data
TP 65
-340/2
-410/2
-460/2
-550/2
-660/2
-720/2
-930/2
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
300
300
1~ TP
3~ TP
132
132
160
160
160
180
200
1~ TPE
3~ TPE
132
132
160
160
160
180
-/30
1~/3~ TP [kW]
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
1~/3~ TPE
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
[kW]
PN
Tmin;Tmax
D1
[mm]
65
65
65
65
65
65
65
1~/3~ TP
[mm]
-/220
-/260
-/314
-/314
-/314
-/314
-/407
1~/3~ TPE
[mm]
-/220
-/260
-/314
-/314
-/314
-/314
1~/3~ TP
[mm]
-/134
-/159
-/204
-/204
-/204
-/204
-/315
AC
AD
1~/3~ TPE
[mm]
-/188
-/213
-/308
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/145
-/210
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/145
-/210
-/210
-/210
-/210
[mm]
300
300
350
350
350
350
400
B1
B2
B3
[mm]
320
320
440
440
440
440
440
B4
[mm]
-/385
-/396
-/558
-/558
-/558
-/558
C1
C5
[mm]
180/65
180/65
C6
[mm]
175
175
175
175
175
175
175
L1
[mm]
360
360
475
475
475
475
475
H1
[mm]
105
105
125
125
125
125
125
H2
[mm]
239
239
263
263
263
263
263
[mm]
-/735
-/723
-/859
-/859
-/903
-/903
-/999
[mm]
-/735
-/723
-/859
-/859
-/903
-/929
[mm]
35
35
35
35
35
M16
M16
M16
M16
M16
M16
M16
H3
H4
M
1~/3~ TP
1~/3~ TPE
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
143
25
DN 80
2-pole, PN 6, 10, 16, 25
+
>P@
7373(
+]
+
>P@
4>PK@
3
>N:@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
(WD
>@
4>PK@
4>OV@
Y>PV@
TM02 5025 2115
Note: All curves apply to single-head pumps. For further information, see page 112.
144
(WD
>@
+]
3
>N:@
7373(
4>PK@
4>OV@
Y>PV@
TP 80-XX/2
25
DN 80
2-pole, PN 6, 10, 16, 25
Technical data
TP 80
-120/2
-140/2
-180/2
-210/2
-240/2
-250/2
-330/2
-400/2
-520/2
-570/2
-700/2
TPD
TPE
TPED
300
Series
IEC size
200
300
300
300
300
300
300
300
300
300
1~ TP
90
3~ TP
90
90
100
112
132
132
160
160
160
180
200
1~ TPE
3~ TPE
100
112
132
132
160
160
160
180
1.5/1.5
-/2.2
-/3
-/4
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
-/30
-/3
-/4
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
PN 6/10
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1
[mm]
AC
AD
80
1~/3~ TP
[mm] 178/178
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 139/139
80
80
80
80
80
80
80
80
80
80
-/178
-/198
-/220
-/220
-/260
-/314
-/314
-/314
-/314
-/402
-/198
-/220
-/220
-/260
-/314
-/314
-/314
-/314
-/110
-/120
-/134
-/134
-/159
-/204
-/204
-/204
-/204
-/315
1~/3~ TPE
[mm]
-/177
-/188
-/188
-/213
-/308
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/132
-/145
-/145
-/145
-/210
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/132
-/145
-/145
-/145
-/210
-/210
-/210
-/210
200
250
250
300
300
350
350
350
350
400
[mm] 135/135
B1
[mm] 120/134 125/296 125/296 125/296 125/296 176/366 176/366 176/366 187/416 187/416 187/416
B2
[mm] 100/225 119/290 119/290 119/290 119/290 144/354 144/354 144/354 162/405 162/405 162/405
B3
[mm]
240
340
340
340
340
400
400
400
470
470
470
B4
[mm]
-/395
-/395
-/538
-/538
-/573
-/573
C1
[mm] 160/240 144/420 144/420 144/420 144/420 144/480 144/480 144/480 144/550 144/550 144/550
C5
[mm]
180/53
180/78
180/78
180/78
180/78
220/93
220/93
220/93
C6
[mm]
173
175
175
175
175
175
175
175
350
350
L1
[mm]
360
360
360
360
360
440
440
440
500
500
500
H1
[mm]
97
105
105
105
105
115
115
115
115
115
115
[mm]
163
H2
H3
H4
M
1~/3~ TP
1~/3~ TPE
[mm] 581/581
176
204
204
243
243
273
273
273
273
273
-/602
-/644
-/681
-/739
-/737
-/859
-/859
-/903
-/903
-/999
[mm]
-/644
-/681
-/739
-/737
-/859
-/859
-/903
-/929
[mm]
35
35
35
35
35
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
145
25
DN 100
2-pole, PN 6, 10, 16, 25
+
>P@
+
>P@
7373(
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>OV@
Y>PV@
4>PK@
4>PK@
TM02 5026 4715
4>PK@
Note: All curves apply to single-head pumps. For further information, see page 112.
146
4>PK@
(WD
>@
+]
3
>N:@
7373(
4>OV@
Y>PV@
TP 100-XX/2
25
DN 100
2-pole, PN 6, 10, 16, 25
Technical data
TP 100
-120/2
-160/2
-200/2
-240/2
-250/2
-310/2
-360/2
-390/2
-480/2
TPD
TPE
TPED
300
Series
IEC size
P2
200
300
300
300
300
300
300
300
1~ TP
3~ TP
90
112
132
132
160
160
160
180
200
1~ TPE
3~ TPE
90
112
132
132
160
160
160
180
-/30
1~/3~ TP [kW]
-/2.2
-/4
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
1~/3~ TPE
-/2.2
-/4
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
PN 6/10
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
[kW]
PN
Tmin;Tmax
[C] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1
[mm]
100
100
100
100
100
100
100
100
100
[mm]
-/178
-/220
-/220
-/260
-/314
-/314
-/314
-/314
-/407
1~/3~ TP
AC
AD
1~/3~ TPE
[mm]
-/122
-/220
-/220
-/260
-/314
-/314
-/314
-/314
1~/3~ TP
[mm]
-/110
-/134
-/134
-/159
-/204
-/204
-/204
-/204
-/315
1~/3~ TPE
[mm]
-/158
-/188
-/188
-/213
-/308
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/134
-/145
-/145
-/145
-/210
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/134
-/145
-/145
-/145
-/210
-/210
-/210
-/210
[mm]
250
300
300
350
350
350
350
400
B1
[mm] 125/245 156/347 156/347 156/347 190/414 190/414 190/414 190/414 201/443
B2
[mm] 100/265 124/332 124/332 124/332 151/395 151/395 151/395 151/395 173/429
B3
[mm]
280
470
470
470
470
500
500
500
500
B4
[mm]
-/340
C1
[mm] 160/280 144/480 144/480 144/480 230/550 230/550 230/550 230/550 230/550
C5
[mm]
225/83
C6
[mm]
221
175
175
175
230
230
230
230
L1
[mm]
450
500
500
500
550
550
550
550
550
H1
[mm]
107
140
140
140
140
140
140
140
140
H2
H3
H4
M
1~/3~ TP
1~/3~ TPE
[mm]
185
206
245
245
270
270
270
270
307
[mm]
-/613
-/718
-/776
-/764
-/881
-/881
-/925
-/925
-/1058
[mm]
-/566
-/718
-/776
-/764
-/881
-/881
-/925
-/951
[mm]
35
35
35
35
35
M16
M16
M16
M16
M16
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
147
25
DN 100
2-pole, PN 6, 10, 16, 25
TP 100-XX/2
+
>P@
3
>N:@
7373(
+]
4>PK@
136+
>P@
(WD
>@
4>PK@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
148
25
DN 100
2-pole, PN 6, 10, 16, 25
Technical data
TP 100
-530/2
-650/2
-800/2
-950/2
-1040/2
-1200/2
-1410/2
TPD
TPE
TPED
300
Series
IEC size
300
300
300
300
300
300
1~ TP
3~ TP
250
250
280
280
315
315
315
1~ TPE
3~ TPE
-/45
-/55
-/75
-/90
-/110
-/132
-/160
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
PN25
PN25
PN25
PN25
PN25
PN25
PN25
Tmin;Tmax
D1
[mm]
100
100
100
100
100
100
100
1~/3~ TP
[mm]
-/442
-/495
-/555
-/555
-/610
-/610
-/610
1~/3~ TPE
[mm]
1~/3~ TP
[mm]
-/325
-/392
-/432
-/432
-/495
-/495
-/495
AC
AD
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
450
550
550
550
660
660
660
B1
[mm]
281/-
281/-
281/-
281/-
281/-
281/-
281/-
B2
[mm]
246/-
246/-
246/-
246/-
246/-
246/-
246/-
B3
[mm]
B4
[mm]
C1
[mm]
230/-
230/-
230/-
230/-
230/-
230/-
230/-
C5
[mm]
335/-
335/-
335/-
335/-
335/-
335/-
335/-
C6
[mm]
L1
[mm]
670
670
670
670
670
670
670
H1
[mm]
175
175
175
175
175
175
175
H2
[mm]
333
338
338
338
366
366
366
1~/3~ TP
[mm]
-/1220
-/1330
-/1333
-/1443
-/1473
-/1633
-/1633
1~/3~ TPE
[mm]
[mm]
35
35
35
35
35
35
35
M16
M16
M16
M16
M16
M16
M16
H3
H4
M
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
149
25
DN 32
4-pole, PN 6, 10, 16, 25
7373(
+
>P@
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
(WD
>@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
150
(WD
>@
+]
3
>N:@
7373(
4>PK@
4>OV@
Y>PV@
25
DN 32
4-pole, PN 6, 10, 16, 25
Technical data
TP 32
-30/4
-40/4
-60/4
-80/4
-100/4
-120/4
TPD
TPE
TPED
300
Series
IEC size
200
200
200
300
300
1~ TP
63
71
71
3~ TP
63
71
71
71
71
80
1~ TPE
3~ TPE
-/0.25
-/0.37
-/0.55
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
PN 6/10
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
1~/3~ TP
[mm] 141/118
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/101
32
32
32
32
32
141/141
141/141
-/141
-/141
-/141
133/133
133/133
-/109
-/109
-/109
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
105/105
170
170
200
B1
[mm]
75/180
100/222
100/222
B2
[mm]
75/180
100/222
100/222
B3
[mm]
200
240
240
C1
[mm]
80/200
80/240
80/240
C5
[mm]
110/52
140/82
140/82
170/45
170/45
C6
[mm]
103
103
103
175
175
175
L1
[mm]
220
280
280
340
340
440
H1
[mm]
68
79
79
100
100
100
H2
[mm]
142
125
125
129
129
156
H3
H4
M
276
276
355
220/46
1~/3~ TP
[mm] 401/390
395/395
395/395
-/420
-/420
-/487
1~/3~ TPE
[mm]
[mm]
M12
M12
M12
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
151
25
DN 40
4-pole, PN 6, 10, 16, 25
+
>P@
+
>P@
7373(
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
TM02 5029 2115
Note: All curves apply to single-head pumps. For further information, see page 112.
152
(WD
>@
+]
3
>N:@
7373(
4>PK@
4>OV@
Y>PV@
TP 40-XXX/4
25
DN 40
4-pole, PN 6, 10, 16, 25
Technical data
TP 40
-30/4
-60/4
-90/4
-100/4
-110/4
-140/4
TPD
TPE
TPED
300
Series
IEC size
200
200
200
300
300
1~ TP
63
71
71
3~ TP
63
71
71
80
80
90
1~ TPE
3~ TPE
-/0.55
-/0.75
-/1.1
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
PN 16
1~/3~ TP
[mm] 141/118
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/101
40
40
40
40
40
141/141
141/141
-/141
-/178
-/178
133/109
133/133
-/109
-/110
-/110
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
105
200
200
200
B1
[mm]
85/180
100/-
100/222
B2
[mm]
75/180
100/-
100/222
B3
[mm]
200
240
C1
[mm] 120/200
120/-
120/240
C5
[mm]
125/45
125/-
160/95
170/45
C6
[mm]
125
125
175
175
175
L1
[mm]
250
250
320
340
440
440
290
355
355
220/108 220/108
H1
[mm]
67
75
68/79
100
110
110
H2
[mm]
146
123
128
166
156
156
H3
H4
M
1~/3~ TP
[mm] 404/393
389/389
388/398
-/497
-/547
-/587
1~/3~ TPE
[mm]
[mm]
M12
M12
M12
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
153
25
DN 50
4-pole, PN 6, 10, 16, 25
+
>P@
+
>P@
7373(
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
TM02 5031 2115
Note: All curves apply to single-head pumps. For further information, see page 112.
154
(WD
>@
+]
3
>N:@
7373(
4>PK@
4>OV@
Y>PV@
TP 50-XXX/4
25
DN 50
4-pole, PN 6, 10, 16, 25
Technical data
TP 50
-30/4
-60/4
-90/4
-80/4
-120/4
-140/4
-190/4
-230/4
TPD
TPE
TPED
300
Series
IEC size
200
200
300
300
300
300
300
1~ TP
71
80
3~ TP
71
71
80
80
90
90
100
100
1~ TPE
3~ TPE
-/0.55
-/0.75
-/1.1
-/1.5
-/2.2
-/3
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
1~/3~ TP
[mm] 141/142
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/133
50
50
50
50
50
50
50
141/141
-/141
-/178
-/178
-/178
-/198
-/198
133/109
-/109
-/110
-/110
-/110
-/120
-/120
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
200
200
200
200
250
250
B1
[mm]
75/181
110/225
B2
[mm]
90/186
100/225
B3
[mm]
200
240
C1
[mm] 120/200
120/240
C5
[mm]
140/60
140/60
170/52
C6
[mm]
125
125
175
175
175
175
175
175
L1
[mm]
280
280
340
440
440
440
440
440
H1
[mm]
82/90
82
115
115
115
115
115
115
H2
[mm]
135
127
161
160
160
160
195
195
-/645
H3
H4
M
320
420
420
420
420
420
1~/3~ TP
[mm] 408/416
452/400
-/507
-/546
-/596
-/596
-/645
1~/3~ TPE
[mm]
[mm]
M12
M12
M16
M16
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
155
25
DN 65
4-pole, PN 6, 10, 16, 25
+
>P@
7373(
+
>P@
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
(WD
>@
4>PK@
4>OV@
Y>PV@
TM02 5033 2115
Note: All curves apply to single-head pumps. For further information, see page 112.
156
(WD
>@
3
>N:@
+]
7373(
4>PK@
4>OV@
Y>PV@
TP 65-XXX/4
25
DN 65
4-pole, PN 6, 10, 16, 25
Technical data
TP 65
-30/4
-60/4
-90/4
-110/4
-130/4
-150/4
-170/4
-240/4
TPD
TPE
TPED
300
Series
IEC size
200
200
300
300
300
300
300
1~ TP
71
80
3~ TP
71
80
80
90
90
100
100
112
1~ TPE
3~ TPE
112
-/4
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
AC
AD
-/0.75
-/1.1
-/1.5
-/2.2
-/3
-/4
PN 6/10
PN 6/10
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
1~/3~ TP
[mm] 141/141
1~/3~ TPE
[mm]
1~/3~ TP
[mm] 133/109
65
65
65
65
65
65
65
141/141
-/178
-/178
-/178
-/198
-/198
-/220
-/220
133/109
-/110
-/110
-/110
-/120
-/120
-/134
1~/3~ TPE
[mm]
-/188
AE
1~/3~ TPE
[mm]
-/145
AF
1~/3~ TPE
[mm]
-/145
[mm]
200
200
200
250
250
250
B1
[mm] 125/230
125/230
B2
[mm] 100/240
100/240
B3
[mm]
C1
[mm] 160/240
160/240
C5
[mm]
170/63
170/63
180/65
C6
[mm]
153
153
175
175
175
175
175
L1
[mm]
340
340
360
475
475
475
475
475
H1
[mm]
97
97
105
125
125
125
125
125
[mm]
135
H2
H3
H4
M
1~/3~ TP
1~/3~ TPE
240
[mm] 423/423
240
320
440
440
164/0
440
164/383 164/383
440
440
147
172
166
166
194
194
194
475/475
-/558
-/612
-/612
-/654
-/654
-/691
-/691
[mm]
[mm]
M16
M16
M16
M16
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
157
25
DN 80
4-pole, PN 6, 10, 16, 25
+
>P@
+
>P@
7373(
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
4>PK@
TM02 5044 2115
Note: All curves apply to single-head pumps. For further information, see page 112.
158
(WD
>@
3
>N:@
+]
7373(
4>OV@
Y>PV@
TP 80-XXX/4
25
DN 80
4-pole, PN 6, 10, 16, 25
Technical data
TP 80
-30/4
-60/4
-70/4
-90/4
-110/4
-150/4
-170/4
-240/4
-270/4
-340/4
TPD
TPE
TPED
300
Series
IEC size
200
200
300
300
300
300
300
300
300
1~ TP
80
90
3~ TP
71
80
90
90
100
100
112
132
132
160
1~ TPE
3~ TPE
112
112
132
132
160
0.37/0.37
0.75/0.75
-/1.1
-/1.5
-/2.2
-/3
-/4
-/5.5
-/7.5
-/11
-/3
-/4
-/5.5
-/7.5
-/11
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
PN 6/PN 10 PN 6/PN 10
Tmin;Tmax
[C]
D1
AC
AD
[-25;140]
[-25;140]
[mm]
80
80
80
80
80
80
80
80
80
80
1~/3~ TP
[mm]
142/141
178/178
-/178
-/178
-/198
-/198
-/220
-/260
-/260
-/314
1~/3~ TPE
[mm]
-/198
-/220
-/260
-/260
-/314
1~/3~ TP
[mm]
133/109
139/110
-/110
-/110
-/120
-/120
-/134
-/159
-/159
-/204
1~/3~ TPE
[mm]
-/177
-/188
-/213
-/213
-/308
AE
1~/3~ TPE
[mm]
-/132
-/145
-/145
-/145
-/210
AF
1~/3~ TPE
[mm]
-/132
-/145
-/145
-/145
-/210
[mm]
200
200
250
250
250
300
300
350
B1
[mm]
130/230
135/240
B2
[mm]
100/240
100/250
B3
[mm]
240
240
C1
[mm]
160/240
160/240
C5
[mm]
180/53
180/53
220/93
220/93
220/93
C6
[mm]
173
173
175
175
175
175
175
350
350
L1
[mm]
360
360
440
440
440
500
500
620
620
620
H1
[mm]
107
107
115
115
115
115
115
140
140
140
H2
H3
H4
M
1~/3~ TP
1~/3~ TPE
400
400
400
470
470
500
500
500
[mm]
163
153
176
176
204
204
204
273
273
303
[mm]
513/461
551/541
-/612
-/612
-/654
-/654
-/691
-/792
-/842
-/914
-/914
[mm]
-/654
-/691
-/792
-/872
[mm]
35
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
159
25
DN 100
4-pole, PN 6, 10, 16, 25
TP 100-XXX/4
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
160
25
DN 100
4-pole, PN 6, 10, 16, 25
Technical data
TP 100
-30/4
-60/4
-70/4
-90/4
-110/4
-130/4
-170/4
TPD
TPE
TPED
300
Series
IEC size
200
200
300
300
300
300
1~ TP
80
90
3~ TP
80
90
90
100
100
112
132
1~ TPE
3~ TPE
90
90
100
112
112
132
0.55/0.55
1.1/1.1
-/1.5
-/2.2
-/3
-/4
-/5.5
-/1.1
-/1.5
-/2.2
-/3
-/4
-/5.5
PN 16
PN 16
PN 16
PN 16
PN 16
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
PN 6/PN 10 PN 6/PN 10
Tmin;Tmax
[C]
D1
1~/3~ TP
AC
AD
[-25;140]
[-25;140]
[mm]
100
100
100
100
100
100
100
[mm]
141/141
178/178
-/178
-/198
-/198
-/220
-/260
1~/3~ TPE
[mm]
-/122
-/178
-/198
-/198
-/220
-/260
1~/3~ TP
[mm]
133/109
139/110
-/110
-/120
-/120
-/134
-/159
1~/3~ TPE
[mm]
-/158
-/167
-/177
-/177
-/188
-/213
AE
1~/3~ TPE
[mm]
-/134
-/132
-/132
-/132
-/145
-/145
AF
1~/3~ TPE
[mm]
-/134
-/132
-/132
-/132
-/145
-/145
[mm]
200
200
200
250
300
B1
[mm]
175/280
175/280
B2
[mm]
125/305
125/305
B3
[mm]
280
280
470
470
470
500
500
B4
[mm]
-/340
C1
[mm]
200/280
200/280
C5
[mm]
225/83
225/83
C6
[mm]
221
221
230
230
230
230
230
L1
[mm]
450
450
550
550
550
550
550
H1
[mm]
122
122
140
140
140
140
140
H2
[mm]
172
182
173
201
201
261
277
[mm]
525/525
625/625
-/634
-/676
-/676
-/773
-/796
[mm]
-/538
-/634
-/676
-/676
-/773
-/796
[mm]
M16
M16
M16
M16
M16
M16
M16
H3
H4
M
1~/3~ TP
1~/3~ TPE
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
161
25
DN 100
4-pole, PN 6, 10, 16, 25
TP 100-XXX/4
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
162
25
DN 100
4-pole, PN 6, 10, 16, 25
Technical data
TP 100
-140/4
-200/4
-250/4
-330/4
-370/4
-410/4
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
300
1~ TP
3~ TP
132
132
160
160
180
180
1~ TPE
3~ TPE
132
132
160
160
180
1~/3~ TP [kW]
-/5.5
-/7.5
-/11
-/15
-/18.5
-/22
1~/3~ TPE
-/5.5
-/7.5
-/11
-/15
-/18.5
[kW]
PN
PN25
Tmin;Tmax
D1
[mm]
100
100
100
100
100
100
1~/3~ TP
[mm]
-/267
-/260
-/314
-/314
-/368
-/368
1~/3~ TPE
[mm]
-/267
-/260
-/314
-/314
-/314
1~/3~ TP
[mm]
-/167
-/159
-/204
-/204
-/286
-/286
AC
AD
1~/3~ TPE
[mm]
-/167
-/213
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/145
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/145
-/210
-/210
-/210
[mm]
265
300
350
350
350
350
B1
[mm]
290/-
B2
[mm]
249/-
B3
[mm]
C1
[mm]
230/-
C5
[mm]
335/-
C6
[mm]
350
350
350
350
350
L1
[mm]
670
670
670
670
670
670
H1
[mm]
175
175
175
175
175
175
H2
[mm]
254
254
308
308
308
308
[mm]
-/820
-/858
-/954
-/1028
-/998
-/1079
[mm]
-/850
-/888
-/954
-/998
-/1024
[mm]
35
35
35
35
M16
M16
M16
M16
M16
M16
H3
H4
M
1~/3~ TP
1~/3~ TPE
600
600
600
600
600
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
163
25
DN 125
4-pole, PN 6, 10, 16, 25
TP 125-XXX/4
+
>P@
7373(
+]
3
>N:@
136+
>P@
164
4>OV@
Y>PV@
(WD
>@
25
DN 125
4-pole, PN 6, 10, 16, 25
Technical data
TP 125
-60/4
-80/4
TPD
-95/4
-
TPE
TPED
Series
300
300
300
IEC size
P2
1~ TP
3~ TP
100
100
112
1~ TPE
3~ TPE
100
100
112
1~/3~ TP [kW]
-/2.2
-/3
-/4
1~/3~ TPE
-/2.2
-/3
-/4
PN 16
PN 16
PN 16
[kW]
PN
Tmin;Tmax
D1
[mm]
125
125
125
1~/3~ TP
[mm]
-/198
-/198
-/220
1~/3~ TPE
[mm]
-/198
-/198
-/220
1~/3~ TP
[mm]
-/120
-/120
-/134
1~/3~ TPE
[mm]
-/177
-/177
-/188
AE
1~/3~ TPE
[mm]
-/132
-/132
-/145
AF
1~/3~ TPE
[mm]
-/132
-/132
-/145
[mm]
250
250
250
B1
[mm]
243/-
243/-
243/-
B2
[mm]
193/-
193/-
193/-
B3
[mm]
L1
[mm]
620
620
620
H1
[mm]
210
210
210
H2
[mm]
-/225
-/225
-/225
1~/3~ TP
[mm]
-/770
-/770
-/807
1~/3~ TPE
[mm]
-/770
-/770
-/807
AC
AD
H3
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
165
25
DN 125
4-pole, PN 6, 10, 16, 25
+
>P@
+
>P@
7373(
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
166
(WD
>@
3
>N:@
+]
7373(
+]
4>PK@
4>OV@
Y>PV@
TP 125-XXX/4
25
DN 125
4-pole, PN 6, 10, 16, 25
Technical data
TP 125
-110/4
-130/4
-160/4
-150/4
-190/4
-230/4
-300/4
-340/4
-400/4
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
300
300
300
300
1~ TP
3~ TP
112
132
132
132
160
160
180
180
200
1~ TPE
3~ TPE
112
132
132
132
160
160
180
1~/3~ TP [kW]
-/4
-/5.5
-/7.5
-/7.5
-/11
-/15
-/18.5
-/22
-/30
1~/3~ TPE
-/4
-/5.5
-/7.5
-/7.5
-/11
-/15
-/18.5
PN 16
PN 16
PN 16
PN 25
[kW]
PN
Tmin;Tmax
[C] [-25;120] [-25;120] [-25;120] [-40;150] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1
[mm]
125
125
125
125
125
125
125
125
125
1~/3~ TP
[mm]
-/220
-/260
-/260
-/267
-/314
-/314
-/368
-/368
-/408
1~/3~ TPE
[mm]
-/220
-/260
-/260
-/267
-/314
-/314
-/314
1~/3~ TP
[mm]
-/134
-/159
-/159
-/167
-/204
-/204
-/286
-/286
-/315
AC
AD
1~/3~ TPE
[mm]
-/188
-/213
-/213
-/167
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/145
-/145
-/145
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/145
-/145
-/145
-/210
-/210
-/210
[mm]
250
300
300
265
350
350
350
350
400
B1
[mm]
-/537
250/537 250/537
244/-
244/537
244/537
273/568
273/568
273/568
B2
[mm]
-/518
202/518 202/518
220/-
220/516
220/516
236/545
236/545
236/545
B3
[mm]
600
600
600
600
600
600
C1
[mm]
-/680
230/680 230/680
230/-
230/680
230/680
230/680
230/680
230/680
C5
[mm]
-/84
310/84
310/84
400/-
400/175
400/175
400/175
400/175
400/175
C6
[mm]
300
300
300
350
350
350
350
350
L1
[mm]
620
620
620
800
800
800
800
800
800
H1
[mm]
215
215
215
215
215
215
215
215
215
H2
[mm]
267
283
283
318
315
315
312
312
312
[mm]
-/854
-/877
-/927
-/906
-/1075
-/1105
-/1085
-/1115
-/1163
[mm]
-/854
-/877
-/969
-/966
-/1045
-/1045
-/1068
[mm]
35
35
35
35
35
M16
M16
M16
M16
M16
M16
M16
M16
M16
H3
H4
M
1~/3~ TP
1~/3~ TPE
600
600
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
167
25
DN 150
4-pole, PN 6, 10, 16, 25
TP 150-XXX/4
+
>P@
7373(
+]
3
>N:@
136+
>P@
168
4>OV@
Y>PV@
(WD
>@
25
DN 150
4-pole, PN 6, 10, 16, 25
Technical data
TP 150
-70/4
-110/4
-155/4
TPD
-170/4
-
TPE
TPED
Series
300
300
300
300
IEC size
P2
1~ TP
3~ TP
132
132
160
160
1~ TPE
3~ TPE
132
160
160
160
1~/3~ TP [kW]
-/5.5
-/7.5
-/11
-/15
1~/3~ TPE
-/5.5
-/7.5
-/11
-/15
PN 16
PN 16
PN 16
PN 16
[kW]
PN
Tmin;Tmax
D1
[mm]
150
150
150
150
1~/3~ TP
[mm]
-/267
-/267
-/320
-/320
1~/3~ TPE
[mm]
-/260
-/260
-/314
-/314
1~/3~ TP
[mm]
-/167
-/167
-/197
-/197
1~/3~ TPE
[mm]
-/213
-/213
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/145
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/145
-/210
-/210
[mm]
300
300
350
350
B1
[mm]
295/-
295/-
295/-
295/-
B2
[mm]
240/-
240/-
240/-
240/-
L1
[mm]
800
800
800
800
H1
[mm]
250
250
250
250
H2
[mm]
284
284
314
314
1~/3~ TP
[mm]
-/913
-/963
-/1109
-/1139
1~/3~ TPE
[mm]
-/913
-/963
-/1079
-/1130
AC
AD
H3
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
169
25
DN 150
4-pole, PN 6, 10, 16, 25
TP 150-XXX/4
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
170
25
DN 150
4-pole, PN 6, 10, 16, 25
Technical data
TP 150
-130/4
-160/4
-200/4
-220/4
-250/4
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
1~ TP
3~ TP
132
160
160
180
180
1~ TPE
3~ TPE
132
160
160
180
1~/3~ TP [kW]
-/7.5
-/11
-/15
-/18.5
-/22
1~/3~ TPE
-/7.5
-/11
-/15
-/18.5
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
150
150
150
150
150
1~/3~ TP
[mm]
-/267
-/314
-/314
-/368
-/368
1~/3~ TPE
[mm]
-/260
-/314
-/314
-/314
1~/3~ TP
[mm]
-/167
-/204
-/204
-/286
-/286
AC
AD
1~/3~ TPE
[mm]
-/213
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/210
-/210
-/210
[mm]
300
350
350
350
350
B1
[mm] 296/583
296/583
296/583
296/583
296/583
B2
[mm] 237/553
237/553
237/553
237/553
237/553
B3
[mm]
600
600
600
600
C1
[mm] 230/680
230/680
230/680
230/680
230/680
C5
[mm] 400/153
400/153
400/153
400/153
400/153
C6
[mm]
350
350
350
350
350
L1
[mm]
800
800
800
800
800
H1
[mm]
215
215
215
215
215
H2
[mm]
291
321
321
321
321
[mm]
-/917
-/1008
-/1082
-/1052
-/1133
[mm]
-/966
-/1008
-/1052
-/1078
-/-
[mm]
35
35
35
35
M16
M16
M16
M16
M16
H3
H4
M
1~/3~ TP
1~/3~ TPE
600
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
171
25
DN 150
4-pole, PN 6, 10, 16, 25
TP 150-XXX/4
+
>P@
3
>N:@
7373(
+]
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
172
4>PK@
4>OV@
Y>PV@
25
DN 150
4-pole, PN 6, 10, 16, 25
Technical data
TP 150
-260/4
-280/4
-340/4
-390/4
TPD
TPE
TPED
Series
300
300
300
300
IEC size
1~ TP
3~ TP
180
180
200
225
1~ TPE
3~ TPE
180
-/18.5
-/22
-/30
-/45
-/18.5
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
150
150
150
150
1~/3~ TP
[mm]
-/368
-/368
-/408
-/442
1~/3~ TPE
[mm]
-/314
1~/3~ TP
[mm]
-/286
-/286
-/315
-/325
AC
AD
1~/3~ TPE
[mm]
-/308
AE
1~/3~ TPE
[mm]
-/210
AF
1~/3~ TPE
[mm]
-/210
[mm]
350
350
400
450
B1
[mm]
335/-
335/-
335/-
373/-
B2
[mm]
288/-
288/-
288/-
333/-
L1
[mm]
800
800
800
1000
H1
[mm]
235
235
235
250
H2
[mm]
319
319
319
352
1~/3~ TP
[mm]
-/1069
-/1150
-/1199
-/1316
1~/3~ TPE
[mm]
-/1095
H3
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
173
25
DN 150
4-pole, PN 6, 10, 16, 25
TP 150-XXX/4
+
>P@
7373(
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
174
4>PK@
4>OV@
Y>PV@
(WD
>@
4>PK@
25
DN 150
4-pole, PN 6, 10, 16, 25
Technical data
TP 150
-450/4
-520/4
TPD
-660/4
-
TPE
TPED
Series
300
300
300
IEC size
1~ TP
3~ TP
225
250
280
1~ TPE
3~ TPE
-/45
-/55
-/75
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
150
150
150
1~/3~ TP
[mm]
-/442
-/495
-/555
1~/3~ TPE
[mm]
1~/3~ TP
[mm]
-/325
-/392
-/432
AC
AD
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
450
550
550
B1
[mm]
373/-
373/-
373/-
B2
[mm]
333/-
333/-
333/-
L1
[mm]
1000
1000
1000
H1
[mm]
250
250
250
H2
[mm]
352
352
352
1~/3~ TP
[mm]
-/1316
-/1419
-/1422
1~/3~ TPE
[mm]
H3
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
175
25
DN 200
4-pole, PN 6, 10, 16, 25
+
>P@
+
>P@
7373(
+]
+]
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
(WD
>@
4>PK@
4>OV@
Y>PV@
4>PK@
TM05 0540 2115
176
7373(
(WD
>@
3
>N:@
4>PK@
Y>PV@
TP 200-XXX/4
25
TPE
TPE
TPE
TPE
TPE
200-50/4
200-70/4
200-90/4
200-130/4
200-150/4
TP,
TP,
TP,
TP,
TP,
TPE
TPE
TPE
TPE
TPE
200-160/4
200-190/4
200-200/4
200-240/4
200-290/4
TP,
TP,
TP,
TP,
TP,
DN 200
4-pole, PN 6, 10, 16, 25
Technical data
TP 200
-50/4
-70/4
-90/4
-130/4
-150/4
-160/4
-190/4
-200/4
-240/4
TPD
-290/4
-
TPE
TPED
Series
300
300
300
300
300
300
300
300
300
300
IEC size
P2
1~ TP
3~ TP
112
132
132
160
160
160
180
180
200
225
1~ TPE
3~ TPE
112
132
160
160
160
160
180
1~/3~ TP [kW]
-/4
-/5.5
-/7.5
-/11
-/15
-/15
-/18.5
-/22
-/30
-/37
1~/3~ TPE
-/4
-/5.5
-/7.5
-/11
-/15
-/15
-/18.5
PN 16
PN 16
PN 16
PN 16
PN 16
[kW]
PN
Tmin;Tmax
[C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1
[mm]
200
200
200
200
200
200
200
200
200
200
1~/3~ TP
[mm]
-/220
-/267
-/267
-/320
-/320
-/320
-/368
-/368
-/408
-/449
1~/3~ TPE
[mm]
-/220
-/260
-/260
-/314
-/314
-/314
-/314
1~/3~ TP
[mm]
-/134
-/167
-/167
-/197
-/197
-/197
-/286
-/286
-/315
-/338
AC
AD
1~/3~ TPE
[mm]
-/188
-/213
-/213
-/308
-/308
-/308
-/308
AE
1~/3~ TPE
[mm]
-/145
-/145
-/145
-/210
-/210
-/210
-/210
AF
1~/3~ TPE
[mm]
-/145
-/145
-/145
-/210
-/210
-/210
-/210
[mm]
250
300
300
350
350
350
350
350
400
450
B1
[mm]
363/-
363/-
363/-
363/-
363/-
348/-
348/-
348/-
348/-
348/-
B2
[mm]
283/-
283/-
283/-
283/-
283/-
288/-
288/-
288/-
288/-
288/-
L1
[mm]
900
900
900
900
900
900
900
900
900
900
H1
[mm]
280
280
280
280
280
280
280
280
280
280
H2
H3
[mm]
273
293
293
336
336
331
331
331
331
361
1~/3~ TP
[mm]
-/925
-/945.5
-/984
-/1094
-/1134
-/1050
-/1090
-/1120
-/1256
-/1298
1~/3~ TPE
[mm]
-/925
-/945.5
-/984
-/1094
-/1134
-/1050
-/1134
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
177
25
DN 200
4-pole, PN 6, 10, 16, 25
TP 200-XXX/4
+
>P@
7373(
+]
3
>N:@
136+
>P@
(WD
>@
178
4>OV@
Y>PV@
25
DN 200
4-pole, PN 6, 10, 16, 25
Technical data
TP 200
-270/4
-320/4
-410/4
TPD
TPE
TPED
300
Series
IEC size
300
300
1~ TP
3~ TP
225
250
280
1~ TPE
3~ TPE
-/45
-/55
-/75
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
200
200
200
1~/3~ TP
[mm]
-/449
-/497
-/551
1~/3~ TPE
[mm]
1~/3~ TP
[mm]
-/338
-/410
-/433
AC
AD
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
450
550
550
B1
[mm]
393/-
393/-
393/-
B2
[mm]
328/-
328/-
328/-
L1
[mm]
900
900
900
H1
[mm]
295
295
295
H2
H3
[mm]
377
377
377
1~/3~ TP
[mm]
-/1380
-/1429
-/1492
1~/3~ TPE
[mm]
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
179
25
DN 200
4-pole, PN 6, 10, 16, 25
TP 200-XXX/4
+
>P@
7373(
+]
3
>N:@
136+
>P@
(WD
>@
180
4>OV@
Y>PV@
25
DN 200
4-pole, PN 6, 10, 16, 25
Technical data
TP 200
-330/4
-360/4
-400/4
-470/4
-530/4
-590/4
-660/4
TPD
TPE
TPED
300
Series
IEC size
300
300
300
300
300
300
1~ TP
3~ TP
225
225
250
280
280
315
315
1~ TPE
3~ TPE
-/37
-/45
-/55
-/75
-/90
-/110
-/132
1~/3~ TP [kW]
P2
1~/3~ TPE
[kW]
PN
Tmin;Tmax
[C]
D1
[mm]
200
200
200
200
200
200
200
1~/3~ TP
[mm]
-/449
-/449
-/497
-/551
-/551
-/616
-/616
1~/3~ TPE
[mm]
1~/3~ TP
[mm]
-/338
-/338
-/410
-/433
-/433
-/515
-/515
AC
AD
1~/3~ TPE
[mm]
AE
1~/3~ TPE
[mm]
AF
1~/3~ TPE
[mm]
[mm]
450
450
550
550
550
660
660
B1
[mm]
423/-
423/-
423/-
423/-
423/-
423/-
423/-
B2
[mm]
368/-
368/-
368/-
368/-
368/-
368/-
368/-
L1
[mm]
1000
1000
1000
1000
1000
1000
1000
H1
[mm]
295
295
295
295
295
295
295
H2
[mm]
382
382
382
382
382
412
412
1~/3~ TP
[mm]
-/1325
-/1385
-/1424
-/1497
-/1607
-/1619
-/1784
1~/3~ TPE
[mm]
H3
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
181
25
DN 300
4-pole, PN 6, 10, 16, 25
+
>P@
7373(
+
>P@
4>PK@
3
>N:@
136+
>P@
4>PK@
4>PK@
136+
>P@
4>PK@
4>PK@
4>PK@
(WD
>@
4>PK@
4>OV@
Y>PV@
182
(WD
>@
+]
3
>N:@
7373(
+]
4>PK@
4>OV@
Y>PV@
TP 300-XXX/4
25
DN 300
4-pole, PN 6, 10, 16, 25
Technical data
TP 300
-190/4
-220/4
-250/4
-290/4
-390/4
-420/4
-430/4
-500/4
-550/4
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
300
300
300
300
1~ TP
3~ TP
200L
225S
225M
250M
280S
280M
315S
315M
315M
1~ TPE
3~ TPE
30
37
45
55
75
90
110
132
160
3~ TP
[kW]
3~ TPE
[kW]
PN
Tmin;Tmax
[C] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150]
D1
[mm]
300
300
300
300
300
300
300
300
300
1~/3~ TP
[mm]
-/402
-/442
-/442
-/495
-/555
-/555
-/610
-/610
-/610
1~/3~ TPE
[mm]
1~/3~ TP
[mm]
-/305
-/325
-/325
-/392
-/432
-/432
-/495
-/495
-/495
AC
AD
[mm]
1~/3~ TPE
[mm]
394
450
450
550
550
550
660
660
660
B1
[mm]
438
438
438
460
460
460
438
438
438
B2
[mm]
320
320
320
345
345
345
338
338
338
B5
[mm]
663
663
663
663
663
663
666
666
666
C3
[mm]
570
570
570
570
570
570
570
570
570
C9
[mm]
1150
1150
1150
1150
1150
1150
1150
1150
1150
L1
[mm]
1240
1240
1240
1240
1240
1240
1240
1240
1240
H1
[mm]
348
348
348
317
317
317
340
340
340
H2
[mm]
393
423
423
438
443
443
460
460
455
H3
[mm]
1400
1420
1480
1572
1580
1690
1732
1892
1892
[mm]
20
20
20
20
20
20
20
20
20
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
183
25
DN 350
4-pole, PN 6, 10, 16, 25
+
>P@
7373(
+
>P@
4>PK@
3
>N:@
4>PK@
136+
>P@
4>PK@
136+
>P@
4>PK@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
TM06 6594 1816
184
(WD
>@
3
>N:@
+]
7373(
+]
4>PK@
4>OV@
Y>PV@
TP 350-XXX/4
25
DN 350
4-pole, PN 6, 10, 16, 25
Technical data
TP 350
-230/4
-280/4
-310/4
-360/4
-420/4
-480/4
-530/4
-650/4
-780/4
TPD
TPE
TPED
300
Series
IEC size
P2
300
300
300
300
300
300
300
300
1~ TP
3~ TP
250M
280S
280M
315S
315M
315M
315L
315L
315L
1~ TPE
3~ TPE
55
75
90
110
132
160
200
250
315
3~ TP
[kW]
3~ TPE
[kW]
PN
Tmin;Tmax
[C] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150]
D1
[mm]
350
350
350
350
350
350
350
350
350
1~/3~ TP
[mm]
495
555
555
610
610
-/610
-/610
-/702
-/702
1~/3~ TPE
[mm]
1~/3~ TP
[mm]
392
432
432
495
495
-/495
-/495
-/619
-/619
AC
AD
[mm]
1~/3~ TPE
[mm]
550
550
550
660
660
660
798
798
798
B1
[mm]
515
515
515
521
521
521
475
475
475
B2
[mm]
371
371
371
373
373
373
374
374
374
B5
[mm]
735
735
735
735
735
735
740
740
740
C3
[mm]
660
660
660
660
660
660
660
660
660
C9
[mm]
1310
1310
1310
1310
1310
1310
1310
1310
1310
L1
[mm]
1400
1400
1400
1400
1400
1400
1400
1400
1400
H1
[mm]
403
403
403
361
361
361
385
385
385
H2
[mm]
452
452
452
509
509
509
514
519
519
H3
[mm]
1672
1675
1785
1802
1962
1962
2259
2272
2272
[mm]
20
20
20
20
20
20
20
20
20
TP(E), TP(E)D pumps are primarily fitted with IE3 motors. See Motor data on pages 86.
185
25
DN 400
4-pole, PN 6, 10, 16, 25
+
>P@
73
+
>P@
+]
3
>N:@
4>PK@
136+
>P@
136+
>P@
4>PK@
(WD
>@
4>OV@
Y>PV@
TM02 6848 3615
186
(WD
>@
73
+]
3
>N:@
4>PK@
4>PK@
4>OV@
Y>PV@
TP 400-XXX/4
25
DN 400
4-pole, PN 6, 10, 16, 25
Technical data
TP 400
-470/4
-510/4
-540/4
-670/4
-720/4
-760/4
TPD
TPE
TPED
400
Series
IEC size
P2
400
400
400
400
400
1~ TP
3~ TP
315
355
355
355
400
400
1~ TPE
3~ TPE
[kW]
315
355
400
500
560
630
PN 25
PN 25
PN 25
PN 25
PN 25
PN 25
[C]
[0;150]
[0;150]
[0;150]
[0;150]
[0;150]
[0;150]
PN
Tmin;Tmax
D1D/D1S
AC
[mm]
625
790
790
790
880
AD
[mm]
608
725
725
875
925
925
[mm]
1150
900
900
900
1150
1150
B1
[mm]
448
448
448
448
448
448
B2
[mm]
1064
1064
1064
1064
1064
1064
B5
[mm]
895
895
895
895
895
895
B6
[mm]
800
800
800
800
800
800
B7
[mm]
1066
1066
1066
1066
1066
1066
B8
[mm]
500
500
500
500
500
500
B9
[mm]
564
564
564
564
564
564
C3
[mm]
830
830
830
830
830
830
C4
[mm]
735
735
735
735
735
735
C9
[mm]
1302
1302
1302
1302
1302
1302
880
[mm]
27
27
27
27
27
27
L1
[mm]
1400
1400
1400
1400
1400
1400
H1
[mm]
450
450
450
450
450
450
H2
[mm]
706
706
706
706
706
706
H3
[mm]
2522
2611
2611
2611
2771
2771
187
25
DN 125
6-pole, PN 16
73
+]
3
>N:@
136+
>P@
(WD
>@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
188
25
DN 125
6-pole, PN 16
Technical data
TP 125
-60/6
-70/6
-80/6
-100/6
-130/6
-160/6
TPD
TPE
TPED
300
Series
IEC size
300
300
300
300
300
1~ TP
3~ TP
100
112
132
132
132
160
1~ TPE
3~ TPE
-/1.5
-/2.2
-/3
-/4
-/5.5
-/7.5
1~/3~ TP
P2
[kW]
PN
PN 16
PN 16
PN 16
PN 16
PN 16
PN 16
Tmin;Tmax
D1
[mm]
125
125
125
125
125
125
[mm]
-/198
-/222
-/262
-/262
-/262
-/262
1~/3~ TP
AC
AD
[mm]
-/166
-/177
-/202
-/202
-/202
-/237
AE
AF
250
250
300
300
300
350
[mm]
B1
B2
B3
[mm]
C1
600
600
600
600
600
600
C5
[mm]
310/84
310/84
C6
[mm]
300
300
350
350
350
L1
[mm]
620
620
800
800
800
800
H1
[mm]
215
215
215
215
215
215
H2
H3
H4
M
1~/3~ TP
[mm]
267
267
285
285
282
312
[mm]
-/818
-/836
-/885
-/885
-/932
-/1021
[mm]
M16
M16
M16
M16
M16
M16
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
189
25
DN 150
6-pole, PN 16
73
+]
3
>N:@
4>PK@
136+
>P@
4>PK@
(WD
>@
4>PK@
4>PK@
4>OV@
Y>PV@
Note: All curves apply to single-head pumps. For further information, see page 112.
190
25
DN 150
6-pole, PN 16
Technical data
TP 150
-60/6
-70/6
-90/6
-110/6
TPD
TPE
TPED
300
Series
IEC size
300
300
300
1~ TP
3~ TP
112
132
132
132
1~ TPE
3~ TPE
-/2.2
-/3
-/4
-/5.5
1~/3~ TP
P2
[kW]
PN
PN 16
PN 16
PN 16
PN 16
Tmin;Tmax
D1
[mm]
150
150
150
150
[mm]
-/222
-/262
-/262
-/262
1~/3~ TP
AC
AD
[mm]
-/177
-/202
-/202
-/202
AE
AF
250
300
300
300
[mm]
B1
B2
B3
[mm]
C1
600
600
600
600
C5
C6
[mm]
350
350
350
L1
[mm]
800
800
800
800
H1
[mm]
215
215
215
215
H2
H3
H4
M
1~/3~ TP
350
[mm]
275
291
291
291
[mm]
-/845
-/853
-/891
-/942
[mm]
M16
M16
M16
M16
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
191
26
Weights and shipping volume
192
Pump type
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
Weights
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
32-80
32-120
32-150
32-180
32-200
40-80
40-120
40-150
40-180
40-200
40-240
50-60
50-80
50-120
50-150
50-180
50-200
50-240
65-60
65-80
65-120
65-150
65-180
65-200
80-40
80-120
80-150
80-180
100-40
100-120
100-150
100-180
Gross [kg]
D1 D
D1S
TPE2,
TPE3
TPE2 D,
TPE3 D
TPE2,
TPE3
TPE2 D,
TPE3 D
TPE2,
TPE3
TPE2 D,
TPE3 D
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
24
24
24
24
24
25
25
25
25
25
27
27
27
27
27
27
29
30
29
29
29
30
31
32
35
36
38
39
40
40
42
43
44
44
44
44
44
46
46
46
46
46
49
49
49
49
49
49
52
54
52
52
52
54
56
57
60
61
65
67
68
70
73
76
32
32
32
32
32
33
33
33
33
33
35
35
35
35
35
35
37
38
38
38
38
39
40
41
44
45
46
48
48
49
51
52
53
53
53
53
53
54
54
54
55
55
58
57
57
57
57
58
61
63
61
61
61
62
65
66
68
70
73
76
78
79
83
85
0.034
0.034
0.034
0.034
0.034
0.035
0.035
0.035
0.035
0.035
0.035
0.036
0.036
0.036
0.036
0.036
0.036
0.036
0.044
0.044
0.044
0.044
0.044
0.044
0.049
0.049
0.049
0.049
0.064
0.064
0.064
0.064
0.104
0.104
0.104
0.104
0.104
0.105
0.105
0.105
0.105
0.105
0.105
0.109
0.109
0.109
0.109
0.109
0.109
0.109
0.117
0.117
0.117
0.117
0.117
0.117
0.129
0.129
0.129
0.129
0.168
0.168
0.168
0.168
TP 25-50/2 R
TP 25-80/2 R
TP 25-90/2 R
TP 32-50/2 R
TP 32-80/2 R
TP 32-90/2 R
TP, TPD 32-60/2
TP, TPD 32-120/2
TP, TPD 32-150/2
TP, TPD 32-180/2
TP, TPD 32-230/2
TP, TPD 32-200/2
TP, TPD 32-250/2
TP, TPD 32-320/2
TP, TPD 32-380/2
TP, TPD 32-460/2
TP, TPD 32-580/2
TP 40-50/2
TP, TPD 40-60/2
TP 40-80/2
TP 40-90/2
TP, TPD 40-120/2
TP 40-180/2
TP, TPD 40-190/2
TP, TPD 40-230/2
TP, TPD 40-270/2
TP, TPD 40-240/2
TP, TPD 40-300/2
TP, TPD 40-360/2
TP, TPD 40-430/2
TP, TPD 40-530/2
TP, TPD 40-630/2
TP, TPD 50-60/2
TP, TPD 50-120/2
TP, TPD 50-180/2
TP, TPD 50-160/2
TP, TPD 50-190/2
TP, TPD 50-240/2
TP, TPD 50-290/2
TP, TPD 50-360/2
TP, TPD 50-430/2
TP, TPD 50-420/2
TP, TPD 50-540/2
TP, TPD 50-630/2
TP, TPD 50-710/2
TP, TPD 50-830/2
TP, TPD 50-900/2
TP, TPD 65-60/2
TP, TPD 65-120/2
TP, TPD 65-180/2
TP, TPD 65-170/2
TP, TPD 65-210/2
TP, TPD 65-250/2
TP, TPD 65-340/2
TP, TPD 65-410/2
TP, TPD 65-460/2
TP, TPD 65-550/2
TP, TPD 65-660/2
TP, TPD 65-720/2
TP, TPD 65-930/2
D1D
D1S
G 1/2
G 1/2
G 1/2
G2
G2
G2
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
G 1/2
G 1/2
G 1/2
G2
G2
G2
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
Weights
Net [kg]
Gross [kg]
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
8/8/11/9/9/11/16/32
19/38
23/54
24/54
25/54
42/86
46/93
51/104
63/127
76/151
90/180
12/20/42
12/15/20/41
24/29/54
36/56
39/70
53/107
65/130
70/140
91/186
105/214
141.2/20/45
28/56
28/56
47/94
48/98
54/108
65/131
71/144
86/174
112/230
149/304
165/333
179/363
181/367
196/396
26/53
31/63
38/76
56/118
68/141
73/151
89/178
103/206
151/310
180/369
182/373
197/402
345/699
13/13/13/13/13/14/38/91
45/102
65/130
79/157
95/189
16/16/17/66/133
73/146
96/195
107/218
171.2/67/134
74/150
91/182
114/233
181/367
198/399
184/373
209/422
222/448
70/144
76/157
93/187
105/210
182/372
185/379
210/427
223/454
-
9/9/12/10/11/13/17/33
20/40
26/57
27/57
28/57
47/101
51/109
57/120
68/144
82/169
106/198
13/21/43
14/17/21/43
25/32/59
39/61
42/75
58/124
70/148
75/158
106/204
120/231
172.0/ 21/48
29/58
29/58
52/111
53/114
59/125
70/149
76/161
101/191
127/248
166/325
195/357
196/384
198/388
222/448
27/56
32/65
41/79
62/134
73/158
78/168
104/196
118/224
168/331
197/390
199/394
216/429
364/725
15/15/15/15/15/16/43/95
50/109
70/149
85/176
113/208
18/18/19/72/152
78/165
114/214
126/237
201.2/ 72/153
80/168
109/201
132/252
199/393
228/482
203/399
227/448
240/474
75/163
81/175
112/206
123/229
201/398
204/405
228/453
242/481
-
0.022/0.022/0.039/0.022/0.039/0.039/0.036/0.072
0.036/0.072
0.064/0.082
0.064/0.082
0.064/0.082
0.138/0.3912
0.138/0.3912
0.184/0.3912
0.184/0.4584
0.2176/0.4584
0.2176/0.4584
0.022/0.036/0.072
0.039/0.039/0.036/0.072
0.036/0.064/0.151
0.064/0.151
0.064/0.151
0.184/0.3912
0.184/0.4584
0.184/0.4584
0.2176/0.4584
0.2176/0.4584
0.58/ 0.056/0.072
0.056/0.072
0.056/0.072
0.138/0.3912
0.138/0.3912
0.184/0.3912
0.184/0.4584
0.184/0.4584
0.184/0.4584
0.2176/0.5184
0.7248/0.6507
0.58/0.64
0.7248/0.6507
0.7248/0.6507
0.7248/0.6507
0.056/0.140
0.056/0.140
0.066/0.140
0.184/0.3912
0.184/0.4584
0.184/0.4584
0.184/0.4584
0.184/0.4584
0.7248/0.6507
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.039/0.039/0.039/0.039/0.039/0.039/0.184/0.3912
0.184/0.3912
0.184/0.5184
0.2176/0.5184
0.2176/0.5184
0.039/0.039/0.039/0.184/0.5184
0.184/0.5184
0.2176/0.5184
0.2176/0.5184
0.58/ 0.184/0.5184
0.184/0.5184
0.184/0.5184
0.2176/0.5184
0.7248/1.524
0.58/1.5
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.184/0.5184
0.184/0.5184
0.184/0.5184
0.184/0.5184
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
-
26
193
26
Connection
Pump type
D1D
D1S
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
Weights
Net [kg]
Gross [kg]
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
43/83
61/124
65/132
78/157
93/187
101/211
148/304
160/327
176/349
205/407
350/697
53/108
93/196
108/226
122/254
175/351
204/410
207/414
221/443
384/771
530/660/775/874/1065/1220/1360/-
74/150
80/162
97/195
115/238
181/370
185/377
215/427
228/453
49/100
95/202
112/235
127/264
206/413
209/420
234/468
247/495
-
44/86
74/141
78/149
90/174
105/204
115/230
169/334
180/356
197/379
226/457
371/747
55/113
107/246
122/276
136/304
199/401
228/460
230/464
244/493
425/828
650/780/895/994/1185/1340/1480/-
88/180
94/192
118/225
136/268
203/420
205/425
236/477
249/503
54/106
109/252
134/285
149/314
230/463
233/470
257/518
270/545
-
0.066/0.140
0.184/0.3912
0.184/0.4584
0.184/0.4584
0.184/0.4584
0.2176/0.5184
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.140/0.213
0.2176/0.5184
0.7248/0.5184
0.7248/0.5184
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.797/1.800
2.05 /2.05 /2.05 /2.05 /2.05 /2.05 /2.05 /-
0.184/0.6507
0.184/0.5184
0.7248/0.5184
0.7248/0.5184
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.120/0.370
0.2176/0.6507
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
-
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
194
D1D
D1S
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
Weights
Net [kg]
Gross [kg]
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
15/30
25/32
25/50
35/69
36/71
49/94
17/33
22/42
28/50
41/83
48/101
54/113
24/46
25/50
43/87
55/116
61/128
64/133
69/142
80/165
33/56
33/63
46/92
63/134
65/138
70/160
81/171
80/169
37/68
37/70
67/141
70/148
73/153
88/172
101/199
194/393
205/415
239/484
41/85
52/107
95/191
97/196
107/215
139/282
168/340
210/239/499
274/568
285/589
370/759
380/781
125/129/125/-/393
212/450
222/471
300/288/604
298/623
394/795
404/817
500/1008
101/210
87/171
106/209
180/366
205/416
233/472
52/100
100/201
109/218
106/213
144/292
155/313
240/500
268/556
291/601
330/679
131/133/131/-/403
198/400
223/472
282/592
304/635
354/715
-
16/31
28/33
28/53
40/86
41/88
55/110
18/34
23/43
32/56
45/99
54/117
60/129
25/48
26/52
47/103
61/135
67/147
70/152
75/162
87/181
35/59
34/66
51/109
69/150
71/155
76/166
87/188
87/186
39/71
39/72
80/159
83/165
86/170
102/192
115/218
218/443
229/465
263/534
44/90
55/113
109/208
122/246
131/265
164/332
192/390
225/264/549
298/618
309/640
412/810
422/831
144/148/144/-/443
242/501
252/522
315/318/654
348/674
451/853
462/874
557/1065
108/229
101/201
120/239
204/417
230/466
258/522
56/105
114/251
133/268
130/264
169/342
189/364
290/550
318/606
341/652
380/730
150/152/150/-/453
249/474
273/523
332/642
354/686
424/766
-
0.036/0.072
0.064/0.072
0.036/0.082
0.138/0.3912
0.138/0.3912
0.1632/0.3912
0.036/0.072
0.036/0.072
0.076/0.151
0.138/0.3912
0.1632/0.3912
0.2176/0.3912
0.036/0.072
0.056/0.072
0.138/0.3912
0.1632/0.5184
0.1632/0.5184
0.2176/0.5184
0.2176/0.5184
0.2176/0.5184
0.056/0.140
0.056/0.140
0.1632/0.3912
0.2176/0.3912
0.2176/0.3912
0.2176/0.4584
0.2176/0.4584
0.2176/0.4584
0.056/0.140
0.066/0.140
0.2176/0.3912
0.2176/0.4584
0.2176/0.4584
0.2176/0.5184
0.2176/0.5184
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.140/0.213
0.140/0.213
0.7248/0.6507
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.97/0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.800
0.969/0.969/0.969/-/1.524
0.9696/1.524
0.9696/1.524
0.97/0.9696/1.524
0.9696/1.800
0.9696/1.800
0.9696/1.800
1.800/1.800
0.2176/0.5184
0.2176/0.6507
0.7248/0.6507
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.120/0.370
0.7248/0.6507
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.800
0.969/0.969/0.969/-/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
-
26
195
26
Connection
Pump type
TP 150-70/4
TP 150-110/4
TP 150-155/4
TP 150-170/4
TP, TPD 150-130/4
TP, TPD 150-160/4
TP, TPD 150-200/4
TP, TPD 150-220/4
TP, TPD 150-250/4
TP 150-260/4
TP 150-280/4
TP 150-340/4
TP 150-390/4
TP 150-450/4
TP 150-520/4
TP 150-660/4
TP 200-50/4
TP 200-70/4
TP 200-90/4
TP 200-130/4
TP 200-150/4
TP 200-160/4
TP 200-190/4
TP 200-200/4
TP 200-240/4
TP 200-270/4
TP 200-290/4
TP 200-320/4
TP 200-330/4
TP 200-360/4
TP 200-400/4
TP 200-410/4
TP 200-470/4
TP 200-530/4
TP 200-590/4
TP 200-660/4
TP 300-190/4
TP 300-220/4
TP 300-250/4
TP 300-290/4
TP 300-390/4
TP 300-420/4
TP 300-430/4
TP 300-500/4
TP 300-550/4
TP 350-230/4
TP 350-280/4
TP 350-310/4
TP 350-360/4
TP 350-420/4
TP 350-480/4
TP 350-530/4
TP 350-650/4
TP 350-780/4
TP 400-470/4
TP 400-510/4
TP 400-540/4
TP 400-670/4
TP 400-720/4
TP 400-760/4
D1D
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
300
300
300
300
300
300
300
300
300
350
350
350
350
350
350
350
350
350
400
400
400
400
400
400
Weights
D1S
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
300
300
300
300
300
300
300
300
300
350
350
350
350
350
350
350
350
350
500
500
500
500
500
500
Net [kg]
Gross [kg]
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
199/214/236/258/-/574
-/643
330/663
415/833
426/854
424/445/502/550/672/827/942/272/279/294/343/369/336/394/409/520/671/588/797/730/766/891/950/1044/1146/1311/1513/765/865/905/1115/1230/1330/1500/1660/1795/1270/1385/1485/1715/1870/2010/2230/2405/2455/3680/4200/4200/4400/5000/5200/-
209/222/255/310/-/575
-/631
336/675
375/753
388/276/289/302/362/388/355/358/-
372/387/409/431/-/624
-/693
380/714
472/891
483/912
592/689/672/719/870/1025/1140/445/452/467/516/542/509/567/587/718/840/786/996/933/969/1090/1148/1243/1379/1543/1745/895/995/1035/1275/1390/1490/1660/1820/1955/1440/1555/1655/1885/2120/2260/2550/2725/2775/4120/4640/4640/4840/5440/5640/-
382/395/428/483/-/625
-/681
386/756
425/804
561/449/462/475/535/561/528/532/-
2.3/2.3/2.3/2.3/-/1.524
-/1.524
0.9696/1.800
0.9696/1.800
0.9696/1.800
2.3/2.3/2.3/2.3/3.1/3.1/3.1/2.3/2.3/2.3/2.3/2.3/2.3/2.3/2.3/3.1/2.3/3.1/3.1/3.1/3.1/3.1/3.1/3.1/4.6/4.6/4.6/2.82/2.82/2.82/3.24/3.24/3.24/3.24/3.24/3.24/3.77/3.77/3.77/3.77/5.26/5.26/6.46/6.46/6.46/10.76/10.76/10.76/10.76/10.76/10.76/-
2.3/2.3/2.3/2.3/-/1.524
-/1.524
0.9696/1.800
0.9696/1.800
2.3/2.3/2.3/2.3/2.3/2.3/2.3/2.3/-
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
196
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
125-60/6
125-70/6
125-80/6
125-100/6
125-130/6
125-160/6
150-60/6
150-70/6
150-90/6
150-110/6
D1D
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
125
125
125
125
125
125
150
150
150
150
Weights
D1S
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
125
125
125
125
125
125
150
150
150
150
Net [kg]
Gross [kg]
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
TP/TPD
TPE/TPED
158/343
164/355
228/479
235/492
246/500
284/575
227/457
261/524
267/538
267/538
188/393
194/405
258/529
265/543
276/550
314/626
257/508
291/574
297/588
297/588
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
26
The dimension before the slash applies to the single-head pump, and the dimension after the slash applies to the twin-head pump.
197
27
P2
[kW]
All
Trimmed impeller
Max. impeller
MEI
0.70
Max. impeller
MEI
*
0.55
0.70
*
0.70
0.70
*
0.70
0.70
Max. impeller
MEI
0.56
0.40
P2
[kW]
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
0.12
0.18
0.37
0.12
0.25
0.37
0.12
0.25
0.37
198
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
25-50/2
25-80/2
25-90/2
32-50/2
32-80/2
32-90/2
40-50/2
40-80/2
40-90/2
R
R
R
R
R
R
Trimmed impeller
Not in MEI classification because flow at best efficiency point is less than 6 m3/h.
P2
[kW]
0.25
0.37
0.37
0.55
0.75
0.25
0.37
0.55
0.75
1.1
1.5
0.37
0.75
0.75
0.55
1.1
1.5
1.5
2.2
32-136 / 111
32-136 / 118
32-136 / 136
Trimmed impeller
0.64
0.70
0.70
0.70
0.44
0.61
0.70
0.60
0.45
0.70
0.70
0.59
0.70
0.70
0.70
P2
[kW]
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
1.1
1.5
2.2
3
4
5.5
2.2
3
4
5.5
7.5
11
1.1
1.5
2.2
3
4
5.5
7.5
11
15
15
18.5
22
2.2
3
4
5.5
7.5
11
15
18.5
22
30
2.2
3
4
5.5
7.5
11
15
18.5
22
30
4
5.5
7.5
11
15
18.5
22
30
32-160.1 / 129
32-160.1 / 140
32-160.1 / 155
32-160.1 / 169
32-200.1 / 188
32-200.1 / 205
32-160 / 137
32-160 / 151
32-160 / 163
32-200 / 186
32-200 / 202
32-200 / 219
32-125 / 110
32-125 / 120
32-125 / 130
32-125 / 142
32-160 / 163
32-160 / 177
40-200 / 187
40-200 / 207
40-200 / 210
40-250 / 230
40-250 / 245
40-250 / 255
40-125 / 116
40-125 / 127
40-125 / 138
40-160 / 158
40-160 / 172
50-200 / 185
50-200 / 200
50-200 / 219
50-250 / 230
50-250 / 257
50-125 / 105
50-125 / 115
50-125 / 125
50-125 / 135
65-160 / 145
65-160 / 157
65-160 / 173
65-200 / 190
65-200 / 200
65-200 / 219
65-125 / 120-110
65-125 / 127
65-125 / 137
80-160 / 147-127
80-160 / 153
80-160 / 163
80-160 / 169
80-200 / 200
TPD 32-200/2
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD 40-240/2
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD 50-160/2
TPD 50-190/2
TPD 50-240/2
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD 65-930/2
TPD 80-140/2
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD 80-700/2
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD, TPE, TPED
TPD 100-480/2
32-250/2
32-320/2
32-380/2
32-460/2
32-580/2
40-300/2
40-360/2
40-430/2
40-530/2
40-630/2
50-290/2
50-360/2
50-430/2
50-420/2
50-540/2
50-630/2
50-710/2
50-830/2
50-900/2
65-170/2
65-210/2
65-250/2
65-340/2
65-410/2
65-460/2
65-550/2
65-660/2
65-720/2
80-180/2
80-210/2
80-240/2
80-250/2
80-330/2
80-400/2
80-520/2
80-570/2
100-160/2
100-200/2
100-240/2
100-250/2
100-310/2
100-360/2
100-390/2
Trimmed impeller
Max. impeller
MEI
0.70
0.50
0.52
0.70
27
0.70
0.70
0.57
0.70
0.70
0.70
0.53
0.70
0.69
0.68
0.70
0.58
0.70
0.65
199
27
P2
[kW]
0.12
0.25
0.25
0.12
0.25
0.25
0.25
0.37
0.25
0.55
0.37
0.75
0.55
1.1
200
Trimmed impeller
Max. impeller
MEI
*
*
*
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.45
0.70
Not in MEI classification because flow at best efficiency point is less than 6 m3/h.
P2
[kW]
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
0.25
0.37
0.55
0.55
0.75
1.1
0.55
0.75
1.1
1.5
2.2
3
0.75
1.1
1.5
2.2
3
4
1.1
1.5
2.2
3
4
5.5
7.5
11
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
2.2
3
4
4
5.5
7.5
11
15
18.5
22
30
32-160.1 / 152
32-160.1 / 169
32-200.1 / 196
32-160 / 169
32-200 / 194
32-200 / 212
32-160 / 169
40-200 / 176
40-200 / 198
40-200 / 215
40-250 / 240
40-250 / 260
40-160 / 166
50-200 / 180
50-200 / 190
50-200 / 210
50-200 / 219
50-250 / 263
65-160 / 149
65-160 / 165
65-160 / 177
65-200 / 205
65-200 / 219
65-250 / 263
65-315 / 279
65-315 / 309
80-160 / 151-133
80-160 / 161
80-160 / 175
80-200 / 200
80-200 / 222
80-250 / 240
80-250 / 270
80-315 / 299
80-315 / 320
80-315 / 334
100-160 / 160-140
100-160 / 172
100-160 / 176
100-200 / 180
100-200 / 197
100-200 / 211
100-250 / 240
100-250 / 269
100-315 / 295
100-315 / 312
100-315 / 334
TPD 32-80/4
TPD 32-100/4
TPD 32-120/4
TPD 40-100/4
TPD 40-110/4
TPD 40-140/4
TPD 50-90/4
TPD 50-80/4
TPD 50-120/4
TPD 50-140/4
TPD 50-190/4
TPD 50-230/4
TPD 65-90/4
TPD 65-110/4
TPD 65-130/4
TPD 65-150/4
TPD 65-170/4
TPD, TPE, TPED 65-240/4
TPD 80-70/4
TPD 80-90/4
TPD 80-110/4
TPD, TPE, TPED 80-150/4
TPD, TPE, TPED 80-170/4
TPD, TPE, TPED 80-240/4
TPD, TPE, TPED 80-270/4
TPD, TPE, TPED 80-340/4
TPD 100-70/4
TPD 100-90/4
TPD, TPE, TPED 100-110/4
TPD, TPE, TPED 100-130/4
TPD, TPE, TPED 100-170/4
TPD, TPE, TPED 100-200/4
TPD, TPE, TPED 100-250/4
TPD, TPE, TPED 100-330/4
TPD, TPE, TPED 100-370/4
TPD 100-410/4
TPE 125-60/4
TPE 125-80/4
TPE 125-95/4
TPD, TPED 125-110/4
TPD, TPED 125-130/4
TPD, TPED 125-160/4
TPD, TPE, TPED 125-190/4
TPD, TPE, TPED 125-230/4
TPD, TPE, TPED 125-300/4
TPD 125-340/4
TPD 125-400/4
Trimmed impeller
Max. impeller
MEI
0.70
0.69
0.40
0.70
0.50
0.70
0.70
0.70
0.70
0.70
0.68
0.70
0.60
0.70
0.70
0.70
0.45
0.69
0.70
0.46
0.70
0.70
P2
[kW]
5.5
7.5
11
15
7.5
11
15
18.5
22
18.5
22
30
37
45
55
75
4
5.5
75
11
15
15
18.5
22
30
37
22
30
37
45
55
75
37
45
55
75
90
110
132
30
37
45
55
75
90
110
132
160
55
75
90
110
132
160
200
250
315
125-200 / 172-150
125-200 / 196-178
125-200 / 218
125-200 / 226
125-250 / 198
125-250 / 220
125-250 / 243
125-250 / 256
125-250 / 266
125-315 / 275
125-315 / 290
125-315 / 315
125-315 / 333
125-400 / 358
125-400 / 382
125-400 / 432
150-200 / 192-121
150-200 / 200-130
150-200 / 210-156
150-200 / 218-210
150-200 / 224
150-250 / 226-220
150-250 / 236
150-250 / 248
150-250 / 272
150-250 / 285
150-315 / 245
150-315 / 264
150-315 / 278
150-315 / 293
150-315 / 311
150-315 / 338
150-400 / 310
150-400 / 326
150-400 / 343
150-400 / 373
150-400 / 391
150-400 / 412
150-400 / 432
250-315 / 230
250-315 / 256
250-315 / 274
250-350 / 302
250-350 / 347
250-350 / 370
250-400 / 354
250-400 / 375
250-400 / 398
300-315 / 260
300-315 / 290
300-315 / 307
300-350 / 330
300-350 / 350
300-350 / 372
300-400 / 385
300-400 / 425
300-400 / 475
150-130/4
150-160/4
150-200/4
150-220/4
Trimmed impeller
Max. impeller
MEI
0.70
0.65
0.70
27
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
201
27
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
125-60/6
125-70/6
125-80/6
125-100/6
125-130/6
125-160/6
150-60/6
150-70/6
150-90/6
150-110/6
P2
[kW]
1.5
2.2
3
4
5.5
7.5
2.2
3
4
5.5
/
/
/
/
/
/
/
/
/
/
197
216
236
267
295
326
204
220
238
262
Trimmed impeller
Max. impeller
MEI
0.62
0.70
0.70
0.62
TP, PN 25
PN 25
TP Series 300, PN 25
P2
[kW]
All
202
Trimmed impeller
Max. impeller
MEI
**
Accessories
28. Accessories
28
TP, TPE 32 R
Pressure stage
PN 10
PN 10
Size
Product
number
Rp 3/4
529921
Rp 1
529922
Rp 1 1/4
529924
Rp 1
509921
Rp 1 1/4
509922
Pressure stage
TP, TPE 25 R
PN 10
TP, TPE 32 R
PN 10
Size
Product
number
Rp 3/4
519805
Rp 1
519806
Rp 1 1/4
519807
Rp 1 1/4
505539
Bronze pumps
A union kit consists of two bronze union tails, two
brass union nuts and two EPDM gaskets.
The valve housing is of pressure die-cast brass.
Pump type, union
connection
Pressure stage
TP, TPE 25 R B
PN 10
TP, TPE 32 R B
PN 10
Size
Product
number
Rp 3/4
Rp 1
Rp 1 1/4
529971
529972
509971
Pressure stage
TP, TPE 25 R B
PN 10
TP, TPE 32 R B
PN 10
Size
Product
number
Rp 3/4
519805
Rp 1
519806
Rp 1 1/4
519807
Rp 1 1/4
505539
203
28
Accessories
Counter-flanges
Cast-iron pumps
A flange kit consists of two steel flanges, two gaskets
of asbestos-free material IT 200, and the requisite
number of bolts.
Counter-flange
Pump type
Description
Rated pressure
Pipework
connection
Product
number
Threaded
10 bar, EN 1092-2
Rp 1 1/4
539703
For welding
10 bar, EN 1092-2
32 mm,
nominal
539704
Threaded
16 bar, EN 1092-2
Rp 1 1/4
539703
For welding
16 bar, EN 1092-2
32 mm,
nominal
539704
Threaded
10 bar, EN 1092-2
Rp 1 1/2
539701
For welding
10 bar, EN 1092-2
40 mm,
nominal
539702
Threaded
16 bar, EN 1092-2
Rp 1 1/2
539701
For welding
16 bar, EN 1092-2
40 mm,
nominal
539702
Threaded
10 bar, EN 1092-2
Rp 2
549801
For welding
10 bar, EN 1092-2
50 mm,
nominal
549802
Threaded
16 bar, EN 1092-2
Rp 2
549801
For welding
16 bar, EN 1092-2
50 mm,
nominal
549802
Threaded
10 bar, EN 1092-2
Rp 2 1/2
559801
For welding
10 bar, EN 1092-2
65 mm,
nominal
559802
Threaded
16 bar, EN 1092-2
Rp 2 1/2
559801
For welding
16 bar, EN 1092-2
65 mm,
nominal
559802
Threaded
6 bar, EN 1092-2
Rp 3
569902
For welding
6 bar, EN 1092-2
80 mm,
nominal
569901
Threaded
10 bar, EN 1092-2
Rp 3
569802
For welding
10 bar, EN 1092-2
80 mm,
nominal
569801
Threaded
16 bar, EN 1092-2
Rp 3
569802
For welding
16 bar, EN 1092-2
80 mm,
nominal
569801
19
Rp 1
Threaded
78
100
140
For welding
TP, TPE 32
TPD, TPED 32
19
Rp 1
Threaded
88
110
150
For welding
TP, TPE 40
TPD, TPED 40
19
Rp 2
Threaded
102
125
165
For welding
TP, TPE 50
TPD, TPED 50
19
Rp 2
Threaded
122
145
185
For welding
Rp 3
TP, TPE 65
TPD, TPED 65
19
Threaded
204
For welding
138
160
200
TP, TPE 80
TPD, TPED 80
Counter-flange
Rp 4
Pump type
Description
Rated pressure
Pipework
connection
Product
number
Threaded
6 bar, EN 1092-2
Rp 4
579901
For welding
6 bar, EN 1092-2
100 mm,
nominal
579902
Threaded
10 bar, EN 1092-2
Rp 4
98999516
For welding
10 bar, EN 1092-2
100 mm,
nominal
579802
Threaded
16 bar, EN 1092-2
Rp 4
98999516
For welding
16 bar, EN 1092-2
100 mm,
nominal
579802
Threaded
10 bar, EN 1092-2
Rp 5
485367
For welding
10 bar, EN 1092-2
125 mm,
nominal
485368
Threaded
16 bar, EN 1092-2
Rp 5
485367
For welding
16 bar, EN 1092-2
125 mm,
nominal
485368
For welding
10 bar, EN 1092-2
150 mm,
nominal
S1111600
For welding
16 bar, EN 1092-2
150 mm,
nominal
S1111600
19
158
180
220
For welding
Rp 5
Threaded
19
188
210
250
For welding
23
For welding
212
240
285
Threaded
Accessories
28
205
28
Accessories
Bronze pumps
A flange kit consists of two bronze flanges, two
gaskets of asbestos-free material IT 200, and the
requisite number of bolts.
Counter-flange
Pump type
Description
Rated pressure
Pipework
connection
Product
number
Threaded
10 bar, EN 1092-2
Rp 1 1/4
96427029
For welding
10 bar, EN 1092-2
32 mm,
nominal
96427030
Threaded
16 bar, EN 1092-2
Rp 1 1/4
96427029
For welding
16 bar, EN 1092-2
32 mm,
nominal
96427030
Threaded
10 bar, EN 1092-2
Rp 1 1/2
539711
For welding
10 bar, EN 1092-2
40 mm,
nominal
539712
Threaded
16 bar, EN 1092-2
Rp 1 1/2
539711
For welding
16 bar, EN 1092-2
40 mm,
nominal
539712
Threaded
10 bar, EN 1092-2
Rp 2
549811
For welding
10 bar, EN 1092-2
50 mm,
nominal
549812
Threaded
10 bar, EN 1092-2
Rp 2 1/2
559811
For welding
10 bar, EN 1092-2
65 mm,
nominal
559812
Threaded
6 bar, EN 1092-2
Rp 3
96405735
For welding
6 bar, EN 1092-2
80 mm,
nominal
569911
Threaded
10 bar, EN 1092-2
Rp 3
569812
For welding
10 bar, EN 1092-2
80 mm,
nominal
569811
Threaded
6 bar, EN 1092-2
Rp 4
96405737
Threaded
10 bar, EN 1092-2
Rp 4
96405738
19
Rp 1
Threaded
78
100
140
For welding
TP, TPE 32 B
19
Rp 1
TP, TPE 50 B
19
Rp 2
Threaded
102
125
165
For welding
19
Rp 2
Threaded
88
110
150
For welding
122
145
185
For welding
Rp 3
Threaded
TP, TPE 40 B
TP, TPE 65 B
19
For welding
Rp 4
Threaded
206
19
For welding
158
180
220
Threaded
138
160
200
TP, TPE 80 B
PN 6
PN 10/16
PN 6
PN 10/16
1 x 220
90
100
98848068
98848069
1 x 120
90
100
98387529
98387530
1 x 60
70
78
98387527
98387528
1 x 30
70
78
98387531
98387588
1 x 70
100
110
539921
539721
1 x 90
100
110
98387590
98387591
1 x 190
100
110
98387592
98387593
1 x 160
110
125
98387594
98387595
1 x 60
110
125
549924
549824
96281077
96608516
98391271
98391272
98391273
98391274
98391275
98391276
98391277
98391278
D1
H
PN 10/16
Product number
PN 6
Adapter flange
Diameter (D)
[mm]
Height (H)
[mm]
DN
Accessories
28
32
D1
D1
H
40
50
1 x 40
90
102
1 x 135
130
145
D1
65
1 x 20
110
122
80
1 x 80
150
160
100
1 x 100
170
180
D1
D1
207
28
Accessories
Base plates
Pump type
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
Product
number
2 x M16 x 30 mm
00485031
32
40
50
65
80-xx/2
80-70/4
80-90/4
80-110/4
80-150/4
80-170/4
100-160/2
100-200/2
100-240/2
Product
number
Drawing
235
195
35
2x14
00485031
TM00 3755 2602
195
96
2x18
4x14
144
Product
number
2 x M12 x 20 mm
96591246
TP, TPE 32
TP, TPE 40
TP, TPE 50
TP 65-60/2
TP, TPE 65-120/2
TP 65-180/2
TP 65-30/4
TP, TPE 65-60/4
TP, TPE 80
TP, TPE 100
2 x M16 x 30 mm
96591245
Product
number
2 x M16 x 30 mm
96536246
Product
number
Drawing
Product
number
Drawing
235
380
290
230
35
120
200
208
160
80
195
2x18
4x14
4x14
290
96591246
96591245
2x14
2x14
35
4x18
195
2x18
96536246
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
4 x M16 x 30 mm
Product
number
96489381
Pump type
Product
number
4 x M16 x 30 mm
96536248
Product
number
Drawing
Product
number
300
47
2x14
330
47
2x18
67
175
4x18
96489381
475
505
67
350
300
2x14
35
35
Drawing
Accessories
28
96536248
4 x M16 x 30 mm
96536247
100-250/2
100-310/2
100-360/2
100-390/2
100-70/4
100-90/4
100-110/4
100-130/4
100-170/4
Product
number
230
2x18
355
385
2x14
35
Drawing
47
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
Product
number
67
TPD,
TPD,
TPD,
TPD,
TPD,
TPD,
TPD,
TPD,
TPD,
96536247
209
28
Accessories
Blanking flanges
TPE2 D, TPE3 D
Pump type
Product number
98159372
210
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
TPED
96591261
32-60/2
32-120/2
32-150/2
32-180/2
32-230/2
32-200/2
32-250/2
32-320/2
32-380/2
32-460/2
32-580/2
40-60/2
40-120/2
40-190/2
40-230/2
40-270/2
40-240/2
40-300/2
40-360/2
40-430/2
40-530/2
40-630/2
50-60/2
50-120/2
50-180/2
50-160/2
50-190/2
50-240/2
50-290/2
50-360/2
50-430/2
50-420/2
50-540/2
50-630/2
50-710/2
50-830/2
50-900/2
00565055
96495694
96495695
96495696
96525962
96525963
96525964
Pump type
TPD, TPED 65-60/2
TPD, TPED 65-120/2
TPD, TPED 65-180/2
TPD, TPED 65-170/2
TPD, TPED 65-210/2
TPD, TPED 65-250/2
TPD, TPED 65-340/2
TPD, TPED 65-410/2
TPD, TPED 65-340/2
TPD, TPED 65-410/2
TPD, TPED 65-460/2
TPD, TPED 65-550/2
TPD, TPED 65-660/2
TPD, TPED 65-720/2
TPD 65-930/2
TPD, TPED 80-120/2
TPD, TPED 80-140/2
TPD, TPED 80-180/2
TPD, TPED 80-210/2
TPD, TPED 80-240/2
TPD, TPED 80-250/2
TPD, TPED 80-330/2
TPD, TPED 80-400/2
TPD, TPED 80-520/2
TPD, TPED 80-570/2
TPD 80-700/2
TPD, TPED 100-120/2
TPD, TPED 100-160/2
TPD, TPED 100-200/2
TPD, TPED 100-240/2
TPD, TPED 100-250/2
TPD, TPED 100-310/2
TPD, TPED 100-360/2
TPD, TPED 100-390/2
TPD 100-480/2
96591261
00565055
96495694
96495695
96495696
96525962
96525963
96525964
Accessories
28
211
28
Accessories
212
96591261
00565055
96495694
96495695
96495696
96525962
96525963
96525964
TPD, 6-pole
Pump type
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
125-60/6
125-70/6
125-80/6
125-100/6
125-130/6
125-160/6
150-60/6
150-70/6
150-90/6
150-110/6
96591261
00565055
96495694
96495695
96495696
96525962
96525963
96525964
Accessories
28
213
28
Accessories
Insulating kits
TPE2, TPE3
32-80/120/150/180/200
98159366
98063287
TPE2, TPE3
40-80/120/150/180/200/240
98159368
98145675
TPE2, TPE3
50-60/80/120/150/180/200/240
98159367
98145676
TPE2, TPE3
65-60/80/120/150/180/200
98159361
96913593
98159363
98134265
98159362
96913589
Pump type
214
Sensors
Flow sensors
Grundfos Vortex flow
sensor, VFI 1
Type
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
Sensor tube with sensor VFI
sensor tube of 1.4408
VFI
and sensor of 1.4404
VFI
4-20 mA output signal
2 flanges
VFI
5 m cable with M12
VFI
connection in one end
VFI
quick guide.
VFI
VFI
VFI
VFI
VFI
VFI
VFI
1
Flow range
[m3/h]
O-ring
Pipe
connection EPDM FKM
1.3 - 25
DN 32
Connection type
Cast-iron
flange
2-40
DN 40
2-64
DN 50
5.2 - 104
DN 65
8-160
DN 80
12-240
DN 100
Stainless-steel
flange
Product number
Accessories
28
97686141
97686142
97688297
97688298
97686143
97686144
97688299
97688300
97686145
97686146
97688301
97688302
97686147
97686148
97688303
97688304
97686149
97686150
97688305
97688306
97686151
97686152
97688308
97688309
For more information about the VFI sensor, see the data booklet "Grundfos direct sensors", publication number 97790189.
215
28
Accessories
Temperature sensors
Temperature sensor, TTA
Temperature sensor with Pt100 temperature sensor
fitted in a 6 x 100 mm measuring tube made of
stainless steel, DIN 1.4571 and a 4-20 mA sensor built
into a type B head DIN 43.729.
The connecting head is made of painted pressure
die-cast aluminium with Pg 16 screwed connection,
stainless screws and neoprene rubber gasket.
Technical data
Type
TTA (-25) 25
Product number
Measuring range
Measuring accuracy
Response time, (0.9) in
water 0.2 m/s
96430194
-25 - 25 C
without protecting tube:
with oil-filled protecting tube:
Enclosure class
Output signal
Supply voltage
EMC (electromagnetic
compatibility)
Emission:
Immunity:
TTA (0) 25
96432591
96430195
0-25 C
0-150 C
According to IEC 751, class B, 0.3 C at 0 C
28 seconds
75 seconds
IP55
4-20 mA
8-35 VDC
According to EN 50081
According to EN 50082
Accessories
Protecting tube
9 x 50 mm
Type
Product number
Description
Protecting tube
9 x 100 mm
96430201
96430202
Protecting tube of stainless steel SINOX SSH 2 for 6 mm measuring tube.
Pipe connection G 1/2.
Protecting tube
Type
9 x 50
9 x 100
216
L
49
99
28
Iout [mA]
ETSD1-04-020
ETSD1-04-050
20
15
10
T1-T2
Diff. temp.
4
-50 -40 -30 -20 -10
10
20
30 40 50
[C]
Accessories
Technical data
Type
Product number
Measuring range:
Temperature difference
(T1-T2) or (T2-T1)
Supply voltage
Output signal
ETSD1-04-020K045
+ ETSD2-K045
ETSD1-04-050K045
+ ETSD2-K045
ETSD1-
96409362
96409363
ETSD1-
0-20 C
0-50 C
20 C corresponds to 20 mA.
050
50 C corresponds to 20 mA.
1 % FS
2 minutes
Ambient temperature
-25 - 85 C
ETSD2-
Operating temperature of
T1 and T2
-25 - 105 C
ETSD2-
Electrical connection
Storage temperature
-45 - 125 C
045 Specification
Reference temperature, T2.
Yes
Yes, up to 40 V
EMC (electromagnetic
compatibility)
045 Specification
4-20 mA
Repeatability
Enclosure class
15-30 VDC
0.3 % FS
Short-circuit-proof
020
04-
Measuring accuracy
Maximum distance
between T1 and T2
04-
IP65
Emission: According to EN 50081
Immunity: According to EN 50082
217
28
54
140
Accessories
Installation
SW
27
SW
27
45
18
G 1/2
93
SW
27
G 1/2
27
218
Type
Supplier
Measuring range
Product number
WR 52
tmg
(DK: Plesner)
-50 - 50 C
ID8295
Pressure sensors
Sensors for boosting applications
Danfoss pressure sensor kit
Pressure range
[bar]
Product number
0 - 2.5
0-4
0-6
0-10
0-16
0 - 2.5
0-4
0-6
0-10
0-16
96478188
91072075
91072076
91072077
91072078
405159
405160
405161
405162
405163
Accessories
28
Pressure range
[bar]
Product number
0 - 0.6
96611522
0-1
96611523
0 - 1.6
96611524
0 - 2.5
96611525
0-4
96611526
0-6
96611527
0-10
96611550
96491010
Select the differential pressure sensor so that the maximum pressure of the sensor is higher than the maximum differential pressure of the pump.
Pressure transmitter
Type
RPI
Supplier
Measuring
range
[bar]
Grundfos
0 - 0.6
0-1
0 - 1.6
0 - 2.5
0-4
0-6
0-12
0-16
Transmitter
output
[mA]
4-20
Power supply
[VDC]
12-30
Process connection
Product
number
G 1/2
97748907
97748908
97748909
97748910
97748921
97748922
97748923
97748924
Sensor interface
Sensor interface, SI 001 PSU 1
Description
Grundfos Direct Sensors, type SI 001 PSU, is an external power supply for the VFI, DPI
and other transmitters with 24 VDC supply voltage.
The power supply is used when the cable between transmitter and controller is more than
30 metres long.
Product number
96915820
For more information about the PSU sensor interface, see the installation and operating instructions "SI 001 PSU - sensor interface", publication
number 96944355, or quick guide, publication number 96944356.
219
28
Accessories
Functions
Features
Phase-sequence monitoring
indication of current or temperature
input for PTC sensor/thermal switch
indication of temperature in C or F
4-digit, 7-segment display
setting and status reading with Grundfos R100 remote
control
setting and status reading via Grundfos GENIbus fieldbus.
Tripping conditions
Overload
underload (dry running)
temperature
missing phase
phase sequence
overvoltage
undervoltage
power factor (cos )
current unbalance.
Warnings
Overload
underload
temperature
overvoltage
undervoltage
power factor (cos )
run capacitor (single-phase operation)
starting capacitor (single-phase operation)
loss of communication in network
harmonic distortion.
Learning function
Phase sequence (three-phase operation)
run capacitor (single-phase operation)
starting capacitor (single-phase operation)
identification and measurement of Pt100/Pt1000 sensor
circuit.
MP 204
Description
Control MP 204
The Control MP 204 is supplied as a plug-and-play control cabinet solution.
The main switch and LED panel showing power consumption are all you see on the front. Inside you find the MP 204
unit and optional communication interface units.
Cabinet type
Description
Functions
Digital input
Float switch or pressure relay (if no IO 112 is used).
Analog input
Too high motor temperature (Tempcon)
thermistor/PTC, pump
pressure sensor, 4-20 mA (with IO 112).
Relay output
Pump alarm.
Communication
Grundfos Remote Management.
GSM/GPRS
(IO 112 not supported)
Modbus RTU wired
(IO 112 not supported)
PROFIBUS DP
(IO 112 not supported).
Protection
Protects the pump against short-circuit.
Control MP 204
For more information about the MP 204 and Control MP 204, see the data booklet "Control MP 204", publication
number 97770915.
220
Potentiometer
MI 301
The MI 301 is a module with built-in infrared and radio
communication. The MI 301 must be used in
conjunction with Android or iOS-based smart devices
with a Bluetooth connection. The MI 301 has
rechargeable Li-ion battery and must be charged
separately.
Product number
625468
Grundfos GO
Grundfos GO is used for wireless infrared or radio
communication with the pumps.
Various Grundfos GO variants are available. The
variants are described in the following.
Product numbers
Grundfos GO variant
MI 204
Grundfos
Grundfos
Grundfos
Grundfos
MI
MI
MI
MI
202
204
204 including iPod touch
301
Product number
98046376
98424092
98612711
98046408
MI 202
Accessories
28
221
28
GrA6121
GrA 6118
Accessories
Fieldbus protocol
Product number
CIU
CIU
CIU
CIU
CIU
CIU
CIU
CIU
CIU
LonWorks
PROFIBUS DP
Modbus RTU
GSM/GPRS
GRM
BACnet MS/TP
BACnet IP
Modbus TCP
PROFINET IO
96753735
96753081
96753082
96787106
96898819
96893769
100
150
200
250*
271*
300
500
500
500
96753894
Fieldbus protocol
Product number
CIM
CIM
CIM
CIM
CIM
CIM
CIM
CIM
CIM
CIM
GENIbus
LonWorks
PROFIBUS DP
Modbus RTU
GSM/GPRS
GRM
BACnet MS/TP
BACnet IP
Modbus TCP
PROFINET
96824631
96824797
96824793
96824796
96824795
96898815
96893770
050
100
150
200
250*
270*
300
500
500
500
98301408
Description
Product number
97631956
97631957
222
Description
Product number
97631956
97631957
EMC filter
EMC (electromagnetic compatibility to EN 61800-3)
Motor [kW]
4-pole
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
22
Emission/immunity
Emission:
Motors may be installed in residential areas
(first environment), unrestricted distribution,
corresponding to CISPR11, group 1, class B.
Immunity:
Motors fulfil the requirements for both the
first and second environment.
Emission:
The motors are category C3, corresponding
to CISPR11, group 2, class A, and may be
installed in industrial areas (second
environment).
If fitted with an external Grundfos EMC filter,
the motors are category C2, corresponding
to CISPR11, group 1, class A, and may be
installed in residential areas (first
environment).
2-pole
28
Accessories
Product number
96041047
96478309
223
29
1
p NPSH R g --- c 2 0,00001 p + p [bar relative]
s
b
d
2
Temp.
[C]
Ps
NPSH
224
150
4.76
140
3.61
130
2.70
120
1.99
110
1.43
100
1.01
90
0.70
80
0.47
70
0.31
60
0.20
50
0.12
40
0.07
30
0.04
20
0.02
10
0.01
Pd
[bar]
ps
= Minimum inlet pressure in bar.
NPSHR = The required Net Positive Suction Head in
metres head.
(To be read from the NPSH curve at the
highest flow the pump will be delivering).
Pump type
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2,
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
TPE2
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
D,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3,
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
TPE3
D 32-80
D 32-120
D 32-150
D 32-180
D 32-200
D 40-80
D40-120
D 40-150
D 40-180
D 40-200
D 40-240
D 50-60
D 50-80
D 50-120
D 50-150
D 50-180
D 50-200
D 50-240
D 65-60
D 65-80
D 65-120
D 65-150
D 65-180
D 65-200
D 80-40
D 80-120
D 80-150
D 80-180
D 100-40
D 100-120
D 100-150
D 100-180
20 C
60 C
90 C
110 C
120 C
0.1
0.1
0.1
0.1
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.4
0.6
0.7
0.9
0.9
0.1
0.1
0.1
0.1
0.3
0.6
0.1
0.1
0.1
0.3
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.4
0.1
0.1
0.1
0.1
0.2
0.3
0.1
0.3
0.6
0.8
0.9
1.1
1.1
0.1
0.1
0.2
0.2
0.5
0.8
0.1
0.3
0.3
0.5
0.1
0.1
0.2
0.3
0.2
0.2
0.4
0.6
0.9
0.2
0.2
0.5
0.6
0.7
0.8
0.5
0.8
1.1
1.3
1.4
1.6
1.6
0.2
0.3
0.6
0.7
1.0
1.3
0.3
0.9
0.9
1.1
0.4
0.6
0.7
0.8
0.9
0.9
1.1
1.3
1.6
0.9
0.9
1.2
1.3
1.4
1.5
1.2
1.5
1.8
2.0
2.1
2.3
2.3
0.9
1.1
1.4
1.5
1.8
2.1
1
1.5
1.5
1.7
1.1
1.3
1.4
1.5
1.5
1.5
1.7
1.9
2.2
1.5
1.5
1.8
1.9
2.0
2.1
1.8
2.1
2.4
2.6
2.7
2.9
2.9
1.5
1.7
2
2.1
2.4
2.7
1.6
2.1
2.1
2.3
1.7
1.9
2
2.1
29
225
29
Minimum inlet pressure - NPSH
226
p [bar]
Pump type
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.3
0.7
0.9
0.1
0.1
0.1
0.2
0.2
0.4
0.1
0.1
0.1
0.1
0.1
0.2
0.3
0.9
0.9
0.1
0.1
0.4
0.1
0.1
0.3
0.1
0.2
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.7
1.2
0.3
0.7
0.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.2
0.1
0.2
0.1
0.2
0.2
0.2
0.7
0.8
1.2
1.4
0.2
0.3
0.6
0.7
0.7
0.9
0.1
0.2
0.2
0.5
0.4
0.7
0.8
1.4
1.4
0.4
0.4
0.9
0.5
0.6
0.8
0.4
0.7
0.7
0.1
0.1
0.1
0.2
0.2
0.4
0.3
0.5
0.6
1.3
1.2
1.7
0.8
1.2
1.0
0.1
0.2
0.3
0.2
0.2
0.2
0.3
0.4
0.6
1.3
0.5
0.3
0.5
0.2
0.5
0.5
1.0
1.5
1.6
2.0
2.2
0.9
1.0
1.3
1.4
1.4
1.6
0.3
0.5
0.5
1.2
1.2
1.5
1.6
2.2
2.2
1.1
1.1
1.6
1.2
1.3
1.5
1.1
1.5
1.4
0.8
0.8
0.8
0.9
1.0
1.1
1.1
1.3
1.4
2.0
2.0
2.4
1.5
2.0
1.8
0.9
0.9
1.0
0.9
0.9
1.0
1.0
1.1
1.3
2.0
1.5
2.0
2.1
2.5
2.7
1.5
1.6
1.9
2.0
1.9
2.2
1.8
1.7
2.0
2.1
2.7
2.7
1.7
1.6
2.1
1.8
1.9
2.1
1.7
2.0
2.0
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.8
1.9
2.6
2.5
3.0
2.1
2.5
2.3
1.4
1.5
1.6
1.4
1.4
1.5
1.6
1.6
1.9
2.6
3.2
3.7
3.8
4.2
4.4
3.1
3.2
3.5
3.6
3.6
3.8
3.5
3.4
3.7
3.8
4.4
4.4
3.3
3.3
3.8
3.4
3.5
3.7
3.4
3.7
3.7
3.0
3.0
3.0
3.1
3.1
3.3
3.2
3.4
3.6
4.2
4.1
4.6
3.8
4.2
4.0
3.1
3.1
3.2
3.1
3.1
3.1
3.2
3.3
3.5
4.2
p [bar]
20 C 60 C 90 C 110 C 120 C 140 C 150 C
1.2
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.1
0.1
0.6
1.9
0.1
0.1
0.1
0.6
0.6
0.6
1.0
1.5
1.6
1.4
1.3
1.3
1.2
1.2
1.2
1.4
0.2
0.1
0.1
0.1
0.3
0.2
0.4
0.1
0.3
0.8
2.1
0.1
0.1
0.1
0.8
0.8
0.8
1.2
1.7
1.8
1.6
1.5
1.5
1.4
1.4
1.4
1.9
0.7
0.3
0.4
0.5
0.8
0.7
0.9
0.6
0.8
1.3
2.6
0.6
0.4
0.5
1.3
1.3
1.3
1.7
2.2
2.2
2.0
1.9
1.9
1.8
1.8
1.8
2.7
1.4
1.1
1.1
1.3
1.6
1.4
1.6
1.4
1.6
2.1
3.4
1.3
1.2
1.3
2.0
2.0
2.0
2.4
2.9
3.2
3.0
2.9
2.9
2.8
2.8
2.8
3.2
1.9
1.6
1.7
1.8
2.1
2.0
2.2
1.9
2.1
2.6
3.9
1.9
1.7
1.8
2.5
2.6
2.5
3.0
3.5
3.7
3.5
3.4
3.4
3.3
3.3
3.3
4.9
3.6
3.2
3.3
3.4
3.7
3.6
3.8
3.5
3.7
4.2
5.6
3.5
3.3
3.4
4.2
4.2
4.2
4.6
5.1
5.3
5.1
5.0
5.0
4.9
4.9
4.9
6.6
6.4
6.3
6.3
6.2
6.2
6.2
p [bar]
Pump type
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.4
0.1
0.1
0.1
0.1
0.1
0.1
1.0
1.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
1.0
0.8
0.1
0.1
0.1
0.1
0.5
0.4
0.1
0.2
0.5
0.5
0.7
0.1
0.1
0.1
0.1
0.1
0.1
0.4
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.3
0.1
0.1
0.1
0.2
0.1
0.3
0.2
0.1
0.1
0.1
0.2
0.1
0.1
0.1
0.1
0.1
0.2
0.7
0.9
0.1
0.1
0.1
0.1
0.1
0.1
1.5
1.5
0.1
0.1
0.1
0.1
0.2
0.3
0.2
0.3
1.5
1.3
0.1
0.1
0.2
0.6
1.0
0.8
0.5
0.7
1.0
1.0
1.2
0.1
0.1
0.2
0.1
0.2
0.2
0.8
0.2
0.3
0.2
0.3
0.3
0.8
0.9
1.1
0.5
0.5
0.6
0.9
0.8
1.0
0.9
0.6
0.7
0.9
0.9
0.6
0.8
0.7
0.7
0.9
1.0
1.5
1.6
0.6
0.6
0.6
0.6
0.6
0.8
2.2
2.3
0.8
0.7
0.8
0.8
1.0
1.0
0.9
1.1
2.2
2.0
0.8
0.9
1.0
1.3
1.7
1.8
1.2
1.4
1.7
1.7
1.9
0.8
0.9
0.9
0.9
0.9
1.0
1.8
0.9
1.0
0.9
1.0
1.0
1.4
1.4
1.6
1.0
1.1
1.1
1.5
1.4
1.6
1.5
1.2
1.3
1.4
1.5
1.1
1.3
1.3
1.3
1.4
1.5
2.0
2.2
1.1
1.1
1.1
1.2
1.2
1.3
2.8
2.8
1.3
1.2
1.4
1.3
1.5
1.5
1.5
1.6
2.8
2.6
1.3
1.4
1.5
1.9
2.3
2.3
1.8
2.0
2.3
2.3
2.5
1.4
1.4
1.5
1.4
1.5
1.5
2.3
1.5
1.6
1.5
1.5
1.6
3.1
3.1
3.3
2.7
2.7
2.7
3.2
3.1
3.3
3.1
2.8
2.9
3.1
3.2
2.8
3.0
2.9
2.9
3.0
3.1
3.7
3.9
2.7
2.7
2.8
2.8
2.8
2.9
4.5
4.5
2.9
2.8
3.0
2.9
3.1
3.2
3.1
3.2
4.5
4.3
3.0
3.0
3.1
3.5
3.9
3.9
3.4
3.6
3.9
3.9
4.1
3.0
3.1
3.1
3.0
3.1
3.1
3.9
3.1
3.2
3.1
3.2
3.2
5.2
4.7
4.9
5.2
5.2
5.4
5.2
4.4
4.5
4.4
4.5
4.5
TP 150-70/4
TP 150-110/4
TP 150-155/4
TP 150-170/4
TP, TPD 150-130/4
TP, TPD 150-160/4
TP, TPD 150-200/4
TP, TPD 150-220/4
TP, TPD 150-250/4
TP 150-260/4
TP 150-280/4
TP 150-340/4
TP 150-390/4
TP 150-450/4
TP 150-520/4
TP 150-660/4
TP 150-680/4
TP 200-50/4
TP 200-70/4
TP 200-90/4
TP 200-130/4
TP 200-150/4
TP 200-160/4
TP 200-190/4
TP 200-200/4
TP 200-240/4
TP 200-270/4
TP 200-290/4
TP 200-320/4
TP 200-330/4
TP 200-360/4
TP 200-400/4
TP 200-410/4
TP 200-470/4
TP 200-530/4
TP 200-590/4
TP 200-660/4
TP 300-190/4
TP 300-220/4
TP 300-250/4
TP 300-290/4
TP 300-390/4
TP 300-420/4
TP 300-430/4
TP 300-500/4
TP 300-550/4
TP 350-230/4
TP 350-280/4
TP 350-310/4
TP 350-360/4
TP 350-420/4
TP 350-480/4
TP 350-530/4
TP 350-650/4
TP 350-780/4
TP 400-470/4
TP 400-510/4
TP 400-540/4
TP 400-670/4
TP 400-720/4
TP 400-760/4
p [bar]
20 C 60 C 90 C 110 C 120 C 140 C 150 C
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.3
0.1
0.1
0.1
0.1
0.3
0.2
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.5
0.3
0.1
0.5
0.5
0.5
0.5
0.4
0.3
2.0
2.0
2.0
1.5
1.4
1.3
0.5
0.4
0.3
0.7
1.6
0.8
0.8
0.9
1.4
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.3
0.2
0.2
0.1
0.1
0.2
0.2
0.4
0.3
0.2
0.1
0.1
0.5
0.4
0.4
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.1
0.1
0.2
0.4
0.7
0.5
0.3
0.7
0.7
0.7
0.7
0.6
0.5
2.2
2.2
2.2
1.7
1.6
1.5
0.7
0.6
0.5
0.7
1.7
0.9
0.8
0.9
1.5
0.3
0.4
0.5
0.6
0.4
0.4
0.4
0.5
0.6
0.5
0.8
0.7
0.7
0.5
1.0
0.7
0.7
0.9
0.8
0.7
0.5
0.4
1.0
0.9
0.9
0.7
0.4
0.6
0.5
0.3
0.3
0.3
0.7
0.4
0.4
0.7
0.9
1.1
0.9
0.7
1.1
1.1
1.1
1.1
1.0
0.9
2.6
2.6
2.6
2.1
2.0
1.9
1.1
1.0
0.9
1.4
2.3
1.5
1.5
1.5
2.1
1.1
1.1
1.2
1.3
1.1
1.1
1.1
1.2
1.3
1.2
1.5
1.5
1.4
1.2
1.5
1.4
1.4
1.7
1.5
1.4
1.2
1.2
1.7
1.6
1.6
1.4
1.1
1.3
1.2
1.1
1.1
1.0
1.4
1.1
1.1
1.4
1.7
2.1
1.9
1.7
2.1
2.1
2.1
2.1
2.0
1.9
3.6
3.6
3.6
3.1
3.0
2.9
2.1
2.0
1.9
2.1
3.1
2.2
2.2
2.3
2.8
1.6
1.7
1.8
1.9
1.6
1.7
1.7
1.8
1.9
1.8
2.1
2.0
2.0
1.8
1.9
1.9
2.0
2.2
2.1
2.0
1.8
1.7
2.3
2.2
2.1
2.0
1.7
1.9
1.8
1.6
1.6
1.6
1.9
1.6
1.7
2.0
2.2
2.6
2.4
2.2
2.6
2.6
2.6
2.6
2.5
2.4
4.1
4.1
4.1
3.6
3.5
3.4
2.6
2.5
2.4
2.6
3.6
2.8
2.8
2.8
3.4
3.2
3.3
3.4
3.5
3.3
3.3
3.3
3.4
3.5
3.4
3.7
3.6
3.6
3.4
3.5
3.6
3.6
3.8
3.7
3.6
3.4
3.3
3.9
3.8
3.8
3.6
3.3
3.5
3.4
3.2
3.2
3.2
3.6
3.3
3.3
3.6
3.8
4.2
4.0
3.8
4.2
4.2
4.2
4.2
4.1
4.0
5.7
5.7
5.7
5.2
5.1
5.0
4.2
4.1
4.0
4.3
5.2
4.4
4.4
4.5
5.0
4.6
4.6
4.6
4.7
4.8
4.7
5.0
4.9
4.9
4.7
4.8
4.9
5.2
5.1
5.1
4.9
4.6
4.8
4.7
4.5
4.5
4.5
4.9
4.6
4.6
4.9
5.1
5.5
5.3
5.1
5.5
5.5
5.5
5.5
5.4
5.3
7.0
7.0
7.0
6.5
6.4
6.3
5.5
5.4
5.3
5.6
6.5
5.7
5.7
5.8
6.3
29
227
29
Minimum inlet pressure - NPSH
228
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
125-60/6
125-70/6
125-80/6
125-100/6
125-130/6
125-160/6
150-60/6
150-70/6
150-90/6
150-110/6
p [bar]
20 C 60 C 90 C 110 C 120 C 140 C
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.7
0.7
0.7
0.8
0.7
0.7
0.7
0.7
0.8
0.8
1.2
1.3
1.2
1.4
1.3
1.3
1.3
1.3
1.3
1.3
2.8
2.9
2.9
3.0
2.9
2.9
2.9
2.9
2.9
3.0
Project title:
Reference number:
Customer contact:
30
Prepared by:
Date:
Page 1 of
Quotation number:
Operating conditions
Pumped liquid
Type of liquid:
Chemical composition (if available):
Distilled/demineralised water?
Conductivity of distilled/demineralised water:
Minimum liquid temperature:
Maximum liquid temperature:
Vapour pressure of liquid:
Liquid concentration:
Liquid pH value:
Dynamic liquid viscosity:
Kinematic liquid viscosity:
Liquid density:
Specific heat capacity of liquid:
Air/gas in liquid?
Solids in liquid?
Contents of solids in liquid (if available):
Additives in liquid?
Does the liquid crystallise?
When does crystallisation happen?
Yes:
No:
[S/cm]
[C]
[C]
[bar]
%
Yes:
Yes:
Yes:
Yes:
[cP] = [mPa s]
[cSt] = [mm2/s]
[kg/m3]
[kJ/(kgK)]
No:
No:
% of mass
No:
No:
Does the liquid get sticky when volatiles evaporate from the pumped liquid?
Description of sticky circumstances:
Yes:
No:
[C]
[C]
[bar]
%
229
30
Pump sizing
Main duty point:
Max. duty point:
Min. duty point:
[m3/h]
[m3/h]
[m 3/h]
Q:
Q:
Q:
H:
H:
H:
[m]
[m]
[m]
[C]
[m]
Pressure
Minimum inlet pressure:
Maximum inlet pressure:
Discharge pressure (inlet pressure + head):
[bar]
[bar]
[bar]
ATEX marking
Required marking of the pump
Customers equipment group (e.g. II):
Customers equipment category (e.g. 2, 3):
Gas (G) and/or dust (D):
Gas (G):
Dust (D):
[C]
Description/sketch
Detailed description of ATEX application
(attach a drawing if possible):
Yes:
No:
Frequency converter
Frequency converter option wanted?
Control parameter:
Detailed description of requirements
(attach a drawing if possible):
Yes:
Pressure:
System information
Please provide us with information about your system
and maybe a simple sketch. This will give us hints as
to whether you need accessories or monitoring
equipment, or whether you already have a suitable
system which makes it unnecessary to attach any
further equipment.
230
No:
Temperature:
Flow rate:
Other:
31
Downloads
Subject to alterations.
231
V7124417 0516
GRUNDFOS A/S
DK-8850 Bjerringbro . Denmark
Telephone: +45 87 50 14 00
www.grundfos.com
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
ECM: 1185149
Copyright Grundfos Holding A/S