Monostrand Post-Tensioning System

System Description

The strength, serviceability and design flexibility of concrete are greatly


enhanced by the DYWIDAG Monostrand Post-Tensioning System.
DYWIDAG Monostrands are made up of cold-drawn, low-relaxation;
seven wire strands of 0.5" (12.7 mm) or 0.6" (15.2 mm) diameter,
conforming to ASTM A 416. DYWIDAG's small tendon diameters and
small anchor plate dimensions meet the edge dimension requirements
of slabs as thin as 4-½" (114.3 mm).
All components illustrated are for unbonded construction.

The DYWIDAG Wedge-Anchor System


Attached to the formwork for quick
exceeds ACI Code requirements for
positioning of anchors, the pocket
guaranteed ultimate capacity of the
formers create small, clean stressing
tendon, and seating losses are
voids that are easily patched.
reduced to a minimum by the two-
DYWIDAG Monostrand Tendons are
piece wedge design. The system
assembled at the job site from strand,
meets PTI Guide specifications.
which is coated and protected by an
Intermediate anchors can be installed
extruded plastic sheathing. Intermediate
at points along the tendon to suit
and dead end (fixed) anchorages are
construction joints, and the stressing
installed in the plant and stressing
can be applied at these points.
anchorages in the field. Wedges for
DYWIDAG provides plastic pocket
fixed anchorages are hydraulically
formers as part of standard anchor
seated in the plant for positive grip.
hardware.

DYWIDAG Encapsulated
Monostrand System
The DYWIDAG Corrosion
Protection System (CPS) offers the
design engineer and owner the
most dependable and best-
engineered post-tensioning
corrosion-protection system
available today. The anchor in the
CPS system is encapsulated in
high-density polyethylene thus
providing complete protection of the
anchor. The anchor is connected to
the tendon with a tube providing a
positive barrier against penetration
into the tendon.
When the tendon is delivered to
site with the dead end anchorage in The grease, extruded sheathing,
place, a cap filled with grease is strand, and anchorages all meet or
seated into the anchor to ensure a exceed the PTI Guide Specifications
tight seal. After stressing the as noted in the Fifth Edition of the
tendon and burning off the strand Post-Tensioning Manual. With the
extension, a plastic grease filled introduction of this new Corrosion
cap is pushed into the anchor Protection System DYWIDAG is
providing a tight seal. A rubber proud to offer a system believed to be
bushing at the end of the plastic the best available on the market
tube provides seal against today at competitive prices.
penetration.

Monostrand Post-
Tensioning System

Components

Prestressing Strand Properties


Stra Ultim Yiel Cro Ulti Prestressing Nominal Weight
nd ate d ss mat Force *)
Size Stres Str Sec e
Ja Tra An Eff
s ess tion Stre
cki nsf cho ect
Are ngt
ng er rag ive
a h
e **)
ksi \ kip kip kip
in \ ksi \ in² \ kips kips
MP s\ s\ s\ lbs/ft \ kg/m
mm MPa mm² \ kN \ kN
a kN kN kN
243 0.15 41.3 33. 30. 28. 26.
0.5 \ 270 \ \ 3\ \ 0\ 5\ 9\ 8\
0.52 \ 0.775
12.7 1861 167 98.7 183. 14 13 128 11
5 1 7 6.8 5.7 .6 9.2
243 0.21 58.6 46. 43. 41. 38.
0.6 \ 270 \ \ 7\ \ 9\ 2\ 0\ 0\
0.74 \ 1.102
15.2 1861 167 140. 260. 20 19 182 16
5 0 7 8.6 2.2 .4 9.0
*) Low relaxation strand
**) Based on 0.65fpu for estimating purposes. These values can be more accurately
calculated by DYWIDAG for each project, considering time-dependent losses.