com Comparison of Instruments


Name

Labmen

Oxygen Permeability Analyzer (Coulometric sensor method )

Other supplier
Standards: ASTM F2622, ASTM D 3985-1995 Standards:GB/T 19789-2005ASTM D
1 ASTM F 1927 ,ASTM F 1307,etc.
3985-1995YBB00082003,etc.
Principle :Coulometric sensor method
Principle :Coulometric sensor method
3

Test range : 0.02~16,500 cm /m 24h


2 (up to 26000 cm3/m224h by installing hood
device )

Test range :0.1~10,000 cm /m 24h


3

Ours:wide range ,can test high barrier material such as aluminum plated film and aluminum foil
Other supplier :narrow range ,cannot test high barrier material such
as aluminum -plated film and aluminum foil

Test accuracy :0.01 cm /m 24h


Temperature range :15-55 (external
device ,need to buy additionally )
Temperature accuracy : 0.1
Humidity range : 0%RH, 15-90%RH
,100%RH (need to buy additionally )
4 Humidity control method : dual gas flow
Humidity control method :desiccant
Temperature control :international advanced Temperature control :external
5 electromagnetic technology ,integrated module temperature control machine ,water as
,built -in software ,no external part .
media
3

Test accuracy :0.001 cm /m 24h


Temperature range :20-35(built -in module ,no
3 need to buy )
Temperature accuracy : 0.01
Humidity range : 0%RH,5-95%RH

Note

High test accuracy ensures accurate test results ,more suitable for
high barrier material .
Temperature control has high precision and effectivity.
Dual gas flow brings higher accuracy

Oxygen Permeability Analyzer

Electromagnetic technology ,automatic increase and decrease ,no


external device
Ours:two Chambers test independently and continuously.
Not require the data before testing .

6 Number of test sample :2 pieces

Test report :real time display curves of


7 transmission rate,oxygen density ,humidity and
temperature .

Number of test sample :Written 3 pieces


but actually it is 1 piece ,because it is three - Other supplier needs material's data like thickness , before they
test they will input the data to OTR tester ,then it calculates the
chamber average tester with only one
result to the according structure film to make sure the result close
sensor
to the same structure 's film .

Test report :Excel format conversion ,

Curves display and data display ,visual and clear ,meet international
format .

Software :real time display of transmission


rate of every point ,can observe the testing
Software :no monitor of running data ,no
process .With curves of transmission rate
8
visual display of transmission rate ,oxygen
,oxygen density ,humidity and temperature ,you
density ,humidity or temperature .
can easily monitor the instrument running and
interaction of parameters.
9

Calibration : Reference Material

We are the first manufacturer in China that has the Standard Film
,which has been approved by The State Certificate for the Gradation of
the Certified Reference Materials .