Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
SEROLOGY,
PREGNANCY & OBSTETRIC
Clinical Diagnostics
C O M PA N Y
S E RO L O G Y
REFERENCE
PRODUCT
ASOL-0100
ASO Latex
100 Tests
LXCR-0112
CRP Latex
100 Tests
LXRF-0112
RF Latex
100 Tests
LXWR-0112
WAALER ROSE
100 Tests
RPRL-0100
100 Tests
TPHA-0004
TPHA Microplates
TPHA-0100
Over the past decades, the ELITech Group Companies have established a
solid distribution network that operates world-wide. More than twenty
thousand customers have experienced the quality, convenience and
reliability of ELITech products. Local support is provided by dedicated
and well trained sales and service organizations.
5 Units
100 Tests +
5 Microplates
P R E G N A N C Y
&
P RO F I L E
O B S T E T R I C
REFERENCE
PRODUCT
METHODOLOGY
SPECIFICATIONS
RTHC-0040
30 Tests
Immuno-chromatography
PRMT-0050
PMR TEST
50 Tests
PRMT-0100
PMR TEST
100 Tests
D i s t r i b u t e d
C o n t a c t
b y :
Ready-to-use Reagents
Serology
S u b s t r at e s
Enzymes
E l e c t r o ly t e s
Sp e c i f i c P r ot e i n s
C A LIBR AT O RS / STA N D A R D S / CO NTR O LS
ASO
RF
CRP
WR
RPR
TPHA
Pregtest
PMR
D e t a i l s :
ELITech
Clinical Diagnostics
ELITech
Clinical Diagnostics
BIOCHEMISTRY
S TA B L E
L I Q U I D
BIOCHEMISTRY
R ea g ents
S TA B L E
SUBSTRATES
REFERENCE
PRODUCT
L I Q U I D
BIOCHEMISTRY
R ea g ents
S TA B L E
ELECTROLYTES
RATIO R2/R1
METHODOLOGY
LINEARITY
REFERENCE
PRODUCT
L I Q U I D
R ea g ents
SPECIFIC PROTEINS
RATIO R2/R1
METHODOLOGY
Single Reagent
2x125 mL
1/1
2x125 mL
LINEARITY
REFERENCE
PRODUCT
50-150 mg/L
IAPA-0400
50-135 mg/L
IAPB-0400
RATIO R2/R1
METHODOLOGY
LINEARITY
APO A1 IP
1x5 mL + 2x25 mL
0.05-3 g/L
APO B IP
1x5 mL + 2x25 mL
0.09-3.3 g/L
1x5 mL + 2x25 mL
3-220 mg/L
1x5 mL + 2x25 mL
0.02 4 g/L
1x32 mL
Immunoturbidimetry Enhanced
by Latex Particles End point
ALBU-0600
ALBUMIN BCG
Single Reagent
2x125 mL
15-60 g/L
CALA-0600
CALCIUM ARSENAZO
ALBU-0700
ALBUMIN BCG
Single Reagent
4x250 mL
15-60 g/L
CALO-0600
CALCIUM OCPC
BITD-0600
1/4
2x125 mL
CHLO-0600
CHLORIDE
Single Reagent
2x125 mL
10-130 mEq/L
ICRP-0400
CRP IP
BIDI-0600
1/4
2x125 mL
1.5-180 mg/L
FECA-0600
IRON Chromazurol
Single Reagent
2x125 mL
Up to 5 mg/L
IHAP-0400
HAPTOGLOBIN
BITO-0600
1/4
2x125 mL
3-200 mg/L
FEFR-0600
IRON Ferrozine TM
1/20
2x125 mL
0.15-9 mg/L
HBAC-0240
HbA1c
CHSL-0490
CHOLESTEROL PAP SL
Single Reagent
1x100 mL
0.2-6 g/L
MAGN-0600
MAGNESIUM Calmagite
1/1
2x125 mL
3.40-50 mg/L
CHSL-0500
CHOLESTEROL PAP SL
Single Reagent
6x100 mL
0.2-6 g/L
PHOS-0600
PHOSPHORUS UV
Single Reagent
2x125 mL
20-200 mg/L
IIGA-0400
IGA IP
1x5 mL + 2x25 mL
CHSL-0700
CHOLESTEROL PAP SL
Single Reagent
4x250 mL
0.2-6 g/L
IIGG-0400
IGG IP
1x5 mL + 2x25 mL
1-26 g/L
IIGM-0400
IGM IP
1x5 mL + 2x25 mL
0.1-4.5 g/L
IMAL-0400
MICROALBUMIN IP
1x5 mL + 2x25 mL
3-400 mg/L
IORO-0400
OROSOMUCOID
1x5 mL + 2x25 mL
0.05 2 g/L
IPAL-0400
PREALBUMIN
1x5 mL + 2x25 mL
ITRF-0400
TRANSFERRIN IP
1x5 mL + 5x25 mL
0.45-7.5 g/L
CHSL-0507
Single Reagent
6x100 mL
0.2-6 g/L
CHSL-0707
Single Reagent
4x250 mL
0.2-6 g/L
CRCO-0600
CREATININE Jaffe
1/1
2x125 mL
3-150 mg/L
CRCO-0700
CREATININE Jaffe
1/1
4x250 mL
3-150 mg/L
CRSL-0630
CREATININE PAP SL
1/3
2x133 mL
3-300 mg/L
GHSL-0600
GLUCOSE HK SL
1/4
5x125 mL
0.2-9 g/L
GPSL-0490
GLUCOSE PAP SL
Single Reagent
1x100 mL
0.2-4 g/L
GPSL-0500
GLUCOSE PAP SL
Single Reagent
6x100 mL
0.2-4 g/L
GPSL-0700
GLUCOSE PAP SL
Single Reagent
4x250 mL
0.2-4 g/L
GPSL-0507
Single Reagent
6x100 mL
0.2-4 g/L
GPSL-0707
Single Reagent
4x250 mL
0.2-4 g/L
1x80 mL
0.05-2.0 g/L
0.05-2.0 g/L
HDLL-0380
CHOLESTEROL HDL SL 2G
1/3
ENZYMES
REFERENCE
PRODUCT
RATIO R2/R1
PASL-0400
ALP (DEA) SL
1/4
2x62.5 mL
15-700 U/L
PASL-0420
ALP (DEA) SL
1/4
4x62.5 mL
15-700 U/L
PASL-0500
ALP (DEA) SL
1/4
5x125 mL
15-700 U/L
ALSL-0410
1/4
2x62.5 mL
15-250 U/L
ALSL-0430
1/4
4x62.5 mL
15-250 U/L
ALSL-0510
1/4
5x125 mL
15-250 U/L
AMSL-0390
AMYLASE SL
Single Reagent
1x50 mL
AMSL-0400
AMYLASE SL
Single Reagent
6x50 mL
2x1 mL
CRP IP CALIBRATOR H
2x1 mL
10-250 U/L
ICRP-0043
ASSL-0510
1/4
5x125 mL
10-250 U/L
ICRP-0046
CRP IP CONTROL I
2x1 mL
CRP IP CONTROL II
2x1 mL
HEMO-0400
HEMOGLOBIN
Single Reagent
1x50 mL
PRTP-0600
MICROPROTEIN
Single Reagent
2x125 mL
PROB-0600
Single Reagent
2x125 mL
2-140 g/L
CMSL-0430
CK-MB SL
1/4
4x62.5 mL
PROB-0700
Single Reagent
4x250 mL
2-140 g/L
GASL-0400
GAMMA GT SL
1/4
TGML-0425
Single Reagent
6x50 mL
0.25-10 g/L
GASL-0420
GAMMA GT SL
1/4
TGML-0515
Single Reagent
6x100 mL
0.25-10 g/L
LDSL-0410
LDH-P 4+1 SL
1/4
2x62.5 mL
TGML-0700
Single Reagent
4x250 mL
0.25-10 g/L
LDSL-0430
LDH-P 4+1 SL
1/4
4x62.5 mL
TGML-0427
Single Reagent
6x50 mL
TGML-0517
Single Reagent
6x100 mL
TGML-0707
Single Reagent
4x250 mL
URSL-0400
UREA UV SL
1/4
2x62.5 mL
Kinetic Enzymatic UV
0.1-3 g/L
URSL-0420
UREA UV SL
1/4
4x62.5mL
Kinetic Enzymatic UV
0.1-3 g/L
URSL-0500
UREA UV SL
1/4
5x125mL
Kinetic Enzymatic UV
0.1-3 g/L
URSL-0407
1/4
2x62.5mL
Kinetic Enzymatic UV
0.1-3 g/L
URSL-0427
1/4
4x62.5mL
Kinetic Enzymatic UV
0.1-3 g/L
URSL-0507
1/4
5x125mL
Kinetic Enzymatic UV
0.1-3 g/L
AUML-0420
Single Reagent
6x50 mL
5-250 mg/L
AUML-0500
Single Reagent
6x100 mL
5-250 mg/L
AUML-0700
Single Reagent
4x250 mL
5-250 mg/L
AUML-0427
Single Reagent
6x50 mL
5-250 mg/L
5 levels x 1 mL
CKSL-0410
CK NAC SL
1/4
2x62.5 mL
Kinetic UV IFCC
10-1700 U/L
ICRP-0047
15 210 g/L
CKSL-0430
CK NAC SL
1/4
4x62.5 mL
Kinetic UV IFCC
10-1700 U/L
HBAC-0043
4x0.5 mL
0.125-2 g/L
CMSL-0410
CK-MB SL
1/4
2x62.5 mL
10-600 U/L
HBAC-0049
4x0.5 mL
10-600 U/L
IMAL-0042
MICROALBUMIN IP CALIBRATOR H
2x62.5 mL
15-1000 U/L
IMAL-0043
4x62.5 mL
15-1000 U/L
IMAL-0046
MICROALBUMIN IP CONTROL 1
2x1 mL
Kinetic UV SFBC
50-1500 U/L
IMAL-0047
MICROALBUMIN IP CONTROL 2
2x1 mL
Kinetic UV SFBC
50-1500 U/L
IPRO-0041
PROTEIN IP CALIBRATOR H
2x5 mL
0.25-10 g/L
IPRO-0042
PROTEIN IP CALIBRATOR H
2x1 mL
0.25-10 g/L
IPRO-0043
0.25-10 g/L
5-250 mg/L
Single Reagent
4x250 mL
5-250 mg/L
1/4
2x62.5 mL
10-250 mg/L
5x125 mL
IAPO-0048
4x62.5 mL
0.15-7.0 g/L
1/4
25-2000 U/L
1/4
URIC ACID BI SL
2x1 mL
1x80 mL
AUSL-0600
ASSL-0430
1/3
URIC ACID BI SL
IAPO-0042
10-250 U/L
CHOLESTEROL LDL SL 2G
25-2000 U/L
LDLL-0380
AUSL-0400
2x62.5 mL
3x80 mL
AUML-0707
PRODUCT
1/4
1/3
6x100 mL
REFERENCE
CHOLESTEROL HDL SL 2G
Single Reagent
ASSL-0410
HDLL-0390
LINEARITY
ICRP-0042
AUML-0507
METHODOLOGY
1/3
10-250 mg/L
2x1 mL
5 levels x 1 mL
5 levels x 1 mL
C alibrators
REFERENCE
PRODUCT
CALI-0550
4x3 ml
HDLL-0011
1x1 mL
HDLL-0041
4x1 mL
LDLL-0011
1x1 mL
LDLL-0041
4x1 mL
Controls
KIT SIZE UNITIT
F R E E Z E
STANDARDs
REFERENCE
PRODUCT
CHOL-0055
4x5 mL
CREN-0055
4x5 mL
GLUP-0055
4x5 mL
PRTP-0020
4x2 mL
D R I E D
and / O r
PRODUCT
4x2 mL
PACI-0030
ACID PHOSPHATASE
18x3 mL
4x5 mL
CHES-0053
CHOLINESTERASE
16x3 mL
4x5 mL
CUIV-0050
COPPER
5x10 mL
4x5 mL
FECA-0050
IRON TIBC
50 Tests
LACT-0100
LACTATE
10x10 mL
REFERENCE
PRODUCT
PRTP-0022
CONT-0060
10x5 mL
TRIG-0055
CONT-0160
10x5 mL
URUV-0055
CKMB-0900
CK-MB Control
4x3 mL
ACUR-0055
P o w der
R ea g ents
Specifications
THROUGHPUT
Up to 360 tests per hour;
Up to 450 tests per hour with ISE unit.
REAGENT SYSTEM
Two rotors with each 24 positions for
25 ml bottles and 8 positions for 5 ml
bottles. All positions can be assigned
as R1, R2 and R3. Adapters for 5 ml
bottles in 25 ml positions;
10 pairs of 25 ml positions can be
used for 50 ml bottles;
Reagent 1 volume 110 - 400 l;
Reagent 2 volume 0 - 180 l;
Reagent 3 volume 0 - 180 l;
Reagent disk compartment is cooled
to approx. 12C below ambient
temperature;
Preheated reagent needles with
level detection and integrated mixer;
Typical reagent consumption
250 l per test.
SAMPLE SYSTEM
Sample rotor containing:
- 80 barcode read samples positions;
- Inner ring for 20 calibrators and
10 controls;
Stat and pediatric functionality;
Continuous loading;
Internal barcode reading;
Primary tubes (13 or 16 mm OD);
All positions can contain 5 ml or 10 ml
primary tubes or sample cups;
Sample volume 1 - 30 l per test,
programmable in steps of 0.1 l;
Sample probe with level detection
and integrated mixer.
SAMPLE PREDILUTION
(MULTIPLE REAGENT MODE ONLY)
Pre-programmed ratios selectable
from 1:2 to 1:100 with 3 diluents;
Automatic parent calibrator dilution.
PIPETTING SYSTEM (2)
Hamilton syringes and valve block;
Reagent syringe 1000 l;
Sample syringe 100 l.
CUVETTE ROTORS (2)
Semi-disposable rotor with
48 cuvettes. Path length 7 mm;
> 10.000 tests per rotor;
Min. measuring volume 220 l;
Measuring temperature 37C,
controlled by Peltier elements.
WASHING UNITS (2)
Cuvette-washing with 4 x 500 l of
water. The unit is equipped with liquid
sensors. Waste is separated into
diluted and concentrated (sample/
reagent mixture and optional ISE-unit)
waste. Cuvettes are dried before use.
CALCULATION MODES
Prozone check for immunology tests;
Cut-off declaration.
QUALITY CONTROL
Up to 15 different controls can be
defined, 3 per test;
Westgard rules;
Levey-Jennings plots.
CERTIFICATES
CE;
CB;
UL.
LANGUAGES
English, German, Spanish, French,
Italian, Chinese and Dutch;
Other languages on request.
with over 50 years of experience in the design and manufacture of award winning
WEIGHT
190 kg.
DIMENSIONS (FLOORSTANDING)
117 x 115 x 77 cm
(W x H excl. Monitor x D)
OPTIONS
Over the past decades, the ELITech Group Companies have established a solid
CONCENTRATED WASTE
Separate waste container for
concentrated waste.
products. Local support is provided by dedicated and well trained sales and service
The power of
proven quality
COMPUTER
Minimum requirements:
- Pentium based: 800 MHz;
- RAM 128 MB;
- Monitor VGA 1024 x 768 pixels;
- Hard Disk: 2 GB;
- Floppy: 3,5 (1.44 MB);
- CD ROM drive;
- Windows 2000;
- 1 USB for analyser; 1 serial port
for host; 1 or 2 printer port(s).
PRINTER
The application supports two printers
simultaneously; one for patient reports
and one for calibration and system data;
Most printers supported by
Windows can be connected.
export@elitechgroup.com
www.elitechgroup.com
ISE UNIT
Na, K and Cl measurements.
MEASUREMENT CAPABILITIES
(TRIPLE REAGENT MODE)
Additional timings available for three
reagent system.
CHEMISTRY workstation
flexor XL
Part.nr: 6002-700-490-04.
Content of this document is subject to change.
System overview
System overview
Software
Simplicity
the software.
or for specialties.
Working Table
Clinical chemistry;
Special proteins;
B sample rotor
Electrolytes.
Connectivity
System Intelligence
Random access;
STAT handling;
Continuous loading;
Level sensing;
450 tests per hour with ISE) with true Walk Away Capacity
Test incompatibility;
Primary tubes;
Host connection.
Convenience, speed, data management & safety: the Flexor XL fits in every laboratory setting.
The Flexor XL also features optimized results with ELITech Clinical Systems liquid stable ready-to-use reagents;
the perfect match for the Flexor series. Reagents are bar-coded for easy operation and programming.
Specifications
REAGENT AND SAMPLE SYSTEM
One rotor combining both sample and
reagent positions;
Inner rotor ring:
- 30 refrigerated reagent positions
for 10 ml, 25 ml and 50 ml reagent
bottles;
- Cooled to 10C +/-4C at normal
laboratory conditions;
- All reagent positions can be
assigned as R1, R2 and R3;
Outer rotor ring:
- 25 barcode readable positions;
- All positions fit 13x75 mm primary
and secondary tubes and pediatric
cups;
- All positions can be used for
Calibrators, Controls, Normal,
Pediatric and STAT samples.
Pipetting system
1000 l Reagent syringe:
- R1 volume 110 - 400 l;
- R2 volume 0 - 180 l;
- R3 volume 0 - 180 l;
- Programmable in 1 l steps;
100 l Sample syringe;
- Sample volume 2-30 l;
- Programmable in 0.1 l steps.
Programmable dilution ratios
1:5 up to 1:200 in one step
increments with 3 possible diluents;
Pre-heated probe with level detection,
collision protection and integrated
mixer.
CUVETTE ROTOR
Cost effective, semi-disposable
cuvette rotor with 48 cuvettes, path
length 7mm;
>10.000 tests per rotor;
Typical reagent consumption
250 l per test;
Measuring temperature 37C,
controlled by Peltier elements.
LIGHT SOURCE
Quartz-Iodine lamp 12V-20W.
WAVELENGTH RANGE
340 - 800 nm;
Optical unit with 8 position filter
wheel;
Automatic wavelength selection;
340, 405, 505, 546, 578, 620,
660, 700 nm standard installed;
Other wavelenghts available on
request.
PHOTOMETRIC RANGE
-0.1 to 3.0 Absorbance;
Resolution 0.001 Abs.
ANALYTICAL MODES (SINGLE, DUAL
AND TRIPLE REAGENT SYSTEM)
Kinetic measurement with linearity
check;
Mono- and bichromatic end point
measurement with or without
bichromatic reagent blank and/or
sample blank correction;
Two point measurement; with or
without slope blank;
Graphic plot of all measuring points;
Predilution and automatic reflex
dilution as needed;
Non-linear calibration curves;
Prozone check for immunology tests;
Cut-off declaration;
Calculated tests.
QUALITY CONTROL
Up to 15 different controls can be
defined, 3 per test;
Westgard rules;
Levey-Jennings plots;
Quality control statistics.
Water Consumption
~950 mL per hour max,
continuous operation.
STANDARDS and regulations
CE-IVD;
CB;
UL.
DIMENSIONS (BenchTop,
self Contained Unit)
90cm (36in) x 75cm (30in) x 60cm (24in)
(W x H x D);
Weight: 75 kg (165 lbs.).
Interface
State of the art Host-Query interface
available;
Host: RS232 or Ethernet (TCP/IP)
through LIS-2A protocol.
ENVIRONMENTAL CONDITIONS
Temperature: 15 32 C
(59 90 F);
Humidity: 15 85% RH;
Altitude: up to 2000 m;
Plumbing: No dedicated system
water or drain required;
Electrical:
- Voltage: 100 240 Vac;
- Frequency: 50 60 Hz;
- Power (max): 350 VA.
ELITech Clinical Systems is a global leader in BenchTop Chemistry Systems, with over
15,000 Chemistry Systems delivered.
Our mission is to enable better medical decisions by bringing high-value diagnostic
solutions and services to laboratories that are closer to the patient (proximity
laboratories).
ELITech Clinical Systems leadership originates from our ability to continuously
provide differentiated products and services focused to meet the needs of proximity
laboratories. ELITech Clinical Systems markets the Selectra Pro Series, designed to
deliver trouble free results laboratories can trust.
Integrated PC
Touch screen navigation;
Operating System:
Windows Embedded.
OPTIONS
BAR CODE READER*
Hand held CCD bar code reader
used for test requisition, reagent
identification and automated
programing of assays, controls,
and calibrators.
Trouble Free
Operations
workhorse with
True
proven system reliability
lab operations
Simplifies
& reduces error
in class operator
Best
interface, easy to train,
Right Results,
On Time
with mistake
Designed
proofing and error
of difficult
Management
samples
effective, minimizes
Cost
labor, maintenance &
methodologies,
Proven
referenced and traceable
waste
new
to industry standards
The Selectra Pro Series builds on the established robustness and reliability of the
current Selectra systems, resulting from decades of proven experience in the design
and manufacture of award winning BenchTop laboratory products.
Together with a dedicated range of ready-to-use reagents from ELITech Clinical
Systems, the Selectra Pro Series provides an ideal chemistry solution for laboratories
that are closer to the patient.
Over the past decades, the ELITech Group Companies have established a solid
distribution network that operates world-wide. Thousands of customers have
experienced the quality, convenience and reliability of ELITech products. Local support
is provided by dedicated and well trained sales and service organizations.
S E L E C T R A PRO
CHEMISTRY system
reducing capabilities
Support you can count on
THROUGHPUT
Up to 133 photometric tests / hour;
Up to 266 ISE tests / hour.
Belgium
Brazil
France
Italy
T: + 32 9 2820 531
T: + 55 27 3025 1415
T: + 33 4 90 17 54 50
T: + 39 02 48 40 35 42
T: + 44 1442 869320
UK
United States T: + 1 855 354 8324
+ 1 855 - ELITECH
Headquarters
T: + 33 1 41 45 07 13
www.elitechgroup.com
info@elitechgroup.com
The latest in the new Selectra Pro Series, the Selectra ProS* is
the most compact, fully featured system with enhanced performance and best in class operator interface. New system
features enable significant productivity and performance
enhancements not typically found in BenchTop Chemistry
Analysers.
Together with a superior menu of ready-to-use stable-liquid
reagents from ELITech Clinical Systems, the new Selectra
ProS System provides a state of the art, fully integrated
chemistry solution for laboratories that are closer to the
patient.
New
Homepage
Customizable
Integrated State-of-the-Art Dry ISE Technology
Patented solid state electrodes can be left dry when not in
use which limits routine priming of ISE reference solutions.
This reduces reagent consumption and improves cost
effectiveness. The Selectra ProS ISE design incorporates new
control software and hydraulics which significantly enhances
performance and reliability.
HbA1C, CRP, APO A1, APO B, Microalbumin, Transferrin, IGA, IGG, IGM,
S E L ECTRA PRO
Operators
Results
Specifications
THROUGHPUT
Up to 266 tests / hour;
Up to 180 photometric tests / hour
in MONO mode.
Interface
Host: RS232 or Ethernet (TCP/IP)
through LIS-2A protocol.
REAGENT SYSTEM
Refrigerated reagent rotor
controlled with Peltier elements;
Cooled to Cooled to 10C/-2C at
normal laboratory conditions;
32 reagent positions for 10 ml,
25 ml and 50 ml reagent bottles;
Reagent ID and automated
programming of assays and
calibrators via barcode;
Typical reagent consumption
250 ul per test;
All reagent positions can be
assigned as R1, R2 and R3;
Pre-heated needle with level
detection, collision protection and
integrated mixer.
WAVELENGTH RANGE
340 - 800 nm;
Optical unit with 8 position filter
wheel;
Automatic wavelength selection
340, 405, 505, 546, 578, 620,
660, 700 nm standard installed;
Other wavelenghts available on
request.
SAMPLE system
Sample rotor containing:
- Outer segment with 50 barcode
readable positions
- Inner segment with 12 auxiliary
positions
- All positions fit 13x75 mm
primary and secondary tubes and
pediatric cups
- All positions can be used for
Calibrators, Controls, Normal,
Pediatric and STAT samples;
Sample probe with level detection,
integrated mixer and collision
protection;
Programmable dilution rations
1:5 up to 1:200 in one step
increments with 3 possible diluents.
Pipetting system
1000 l Reagent syringe:
- R1 volume 110 - 400 l;
- R2 volume 0 - 180 l;
- R3 volume 0 - 180 l;
- Programmable in 1 l steps;
100 l Sample syringe;
- Sample volume 1-30 l;
- Programmable in 0.1 l steps.
QUALITY CONTROL
Up to 15 different controls can be
defined, 3 per test;
Westgard rules;
Levey-Jennings plots;
Quality control statistics.
CUVETTE ROTOR
Cost effective, semi-disposable
cuvette rotor with 48 cuvettes, path
length 7mm;
LIGHT SOURCE
Quartz-iodine lamp 12V-20W.
ENVIRONMENTAL CONDITIONS
Temperature: 15 32 C;
Humidity: 15 85% RH;
Altitude: up to 2000 m;
Plumbing: No dedicated system
water or drain required;
Electrical:
- Voltage: 100 240 Vac;
- Frequency: 50 60 Hz;
- Power (max): 380 VA.
PHOTOMETRIC RANGE
-0.1 to 3.0 Absorbance;
Resolution 0.001 Abs.
Water Consumption
~500 mL per hour max,
continous operation.
STANDARDS and regulations
CE-IVD;
CB.
Integrated PC
Operating System:
MS Windows XP.
ELITech Clinical Systems is a global leader in BenchTop Chemistry Systems, with over
15,000 Chemistry Systems delivered.
Our mission is to enable better medical decisions by bringing high-value diagnostic
solutions and services to laboratories that are closer to the patient (proximity
laboratories). ELITech Clinical Systems leadership originates from our ability to
continuously provide differentiated products and services focused to proximity
laboratories. ELITech Clinical Systems markets the Selectra Pro Series, designed to
deliver trouble free results laboratories can trust.
Trouble Free
Operations
workhorse with
True
proven system reliability
lab operations
Simplifies
& reduces error
in class operator
Best
interface, easy to train,
Right Results,
On Time
with mistake
Designed
proofing and error
reducing capabilities
of difficult
Management
samples
effective, minimizes
Cost
labor, maintenance &
methodologies,
Proven
referenced and traceable
waste
to industry standards
OPTIONS
Dry Electrode ISE Module
Patented Solid State Electrode
Technology;
Indirect Measurement
Dilution 1:14;
Measures Sodium, Potassium,
Chloride and CO2.
Positive sample identification
Positive Sample Identification
(PSID) via integrated barcode
reader. Reads all popular formats
including Codes 39, 128, 11, 93, 4,
CODABAR, and Interleaved 2/5.
export@elitechgroup.com
www.elitechgroup.com
PRINTER
Printer supported by
MS Windows.
ECO KIT
Enables separate collection of
concentrated measurement mixture
and dilute (wash) waste.
new
The Selectra Pro Series builds on the robustness and reliability of the current Selectra
systems, resulting from decades of proven experience in the design and manufacture
of award winning BenchTop laboratory products. Together with a dedicated range of
ready-to-use reagents from ELITech Clinical Systems, the Selectra Pro Series provides
an ideal chemistry solution for laboratories that are closer to the patient.
Over the past decades, the ELITech Group Companies have established a solid
distribution network that operates world-wide. More than twenty thousand customers
have experienced the quality, convenience and reliability of ELITech products. Local
support is provided by dedicated and well trained sales and service organizations.
CHEMISTRY system
Silver wire
Silver/silver chloride
Reference electrode
HbA1C, CRP, APO A1, APO B, Microalbumin, Transferrin, IGA, IGG, IGM,
through daily tasks, tracking upcoming maintenance, inventory onboard, and expiring calibrations and reagents
Specifications
LIGHT SOURCE
Quartz-halogen lamp 12V-20W.
WAVELENGTH RANGE
Automatic by 12 positions
filterwheel;
6 standard interference filters: 340,
405, 505, 546, 578 and 620 nm;
6 positions for optional filters.
PHOTOMETRIC RANGE
-0.1 to 2.3 Absorbance.
DETECTOR
Photo diode (320-1000 nm).
BLANKING
Automatic zero setting.
OPERATOR INTERFACE
Membrane keyboard, for direct
function and alpha-numeric entry;
Optional external keyboard;
High contrast graphical LCD display;
Real time clock, 24 hours system.
LANGUAGES
English;
Spanish;
French;
German;
Portuguese;
Other languages on request.
MEASUREMENT PROCEDURES
Kinetic, with linearity check:
Kinetic, with linearity check
and sample slope blank;
Two point kinetic, with or without
reagent blank;
End point, with or without reagent
blank;
Bichromatic end point, with or
without reagent blank;
End point, with sample blank and
with or without reagent blank.
MULTIPLE TESTING
Up to nine replicates;
Means, SD and CV.
FLOWCELL
Metal, with quartz windows,
measuring volume 30 l.
MEASURING TIME
Programmable, 2 to 998
seconds for kinetic and
two point type of tests;
For end point fixed at 2
seconds.
TEMPERATURE CONTROL
By means of Peltier elements;
Fixed temperature at 37C.
DELAY TIME
Programmable, 0 to 999
seconds.
METHOD PARAMETER SETTINGS
a.o.
Method name;
Measurement mode;
Wavelenght 1 and 2;
Aspiration volume;
Measurement delay;
Measurement time;
Factor;
Concentration standards;
Reagent blank y/n;
Sample blank y/n;
Units for results;
Levels for flagging;
Curve fit y/n;
Linearity check.
CALIBRATION
Factor, one-point, two-point
and multi-point;
Automatic on 1 standard
(linear mode);
Automatic on up to 10 standards
(non linear mode).
ASPIRATOR SYSTEM
Internal pump of bellows type,
driven by stepper motor:
Back panel connection for waste;
Aspiration volume programmable.
PRINTER
Internal matrix printer;
Normal paper;
External printer port available.
SIGNAL INTERFACE
Centronics type parallel port;
RS 232 type serial port;
PS 2 type port for external
keyboard.
the company
With over 40 years experience in the design and manufacture of award
winning scientific and laboratory instrumentation, Vital Scientific has the
proven expertise and know-how to respond to your needs.
Skilled employees, powerful design tools, precision engineering and a policy
for top quality components lie at the very heart of our good manufacturing
practices.
By accepting nothing but the very best, Vital Scientific - an ISO 9001 compliant
and FDA registered company - is well equipped to meet the highest standards.
Over the past decades, Vital Scientific has established a solid distribution
network that operates world-wide. More than twenty thousand customers have
already experienced the quality, convenience and reliability of our instruments.
QUALITY
UL;
CE;
CB certificate.
Local support is guaranteed by dedicated and well trained sales and service
POWER REQUIREMENTS
100-240 VAC nominal, 50/60 Hz;
Battery back-up to retain data.
The ELITech Group evolution began in 1981 with the founding of Seppim, which
DIMENSIONS
40 x 17 x 36,5 cm (W x H x D).
WEIGHT
8,5 kg.
organisations.
became a member of the Group in 1997. Throughout years they have come to be
a leading European manufacturer of clinical chemistry diagnostic kits with over
25 years of unique expertise in clinical chemistry reagents.
A giant in
performance
Vital Scientific arrived in the ELITech family in October 2007. Combining the
manufacture of clinical chemistry reagents and analysers through its subsidiaries
companies Seppim and Vital Scientific, the ELITech Group now provides a
QUALITY CONTROL
Two controls per test;
QC survey of last 30 control
measurements;
Levey Jenning plot;
High/low flags.
6950 AC Dieren
The Netherlands
www.vitalscientific.com
info@vital.nl
Distributor details:
Microlab 300
Introduction
System overview
Software
Simplicity
Clinical Chemistry
Special Proteins
confirm to you.
Drugs of Abuse
Therapeutic Drugs
Sipper System
Sample evaluation
Electrolytes
On-Board Quality Control
The new Microlab 300 shows excellent performance
also included.
Quality Control
Calibration Curve
compromises
The full size screen and qwerty keyboard allows
interactive and intuitive operation of the Microlab 300.
No strange keystrokes or hardly readable displays. The
Microlab 300 offers trueconvenience and minimizes the
risk of false data input.
of operation;
Reagent volume 30% less than most competing
Maintenance
Sipper System
Patient Results
Host Connection