Sei sulla pagina 1di 10

Ro-Tap E

Manual

Introduction
Only install and start the Test Sieve shaker after having read the
following operating instructions.
The operating instructions give important information about the secure, appropriate
and economic operation of the Test Sieve shaker. They should be respected in
order to avoid any dangers as well as to maximize the reliability and durability of
the machine.
The safety instructions and regulations of prevention of accidents, as well as the
different protective recommendations of the technical associations and employers
liability insurance associations, have to be strictly observed when using the
machine.

All safety instructions within these operating instructions have to be


followed!
Always keep the operating instructions with the machine.

If used properly, the construction of the machine guarantees that it runs and can
be operated without any risk to persons.

The warranty does not apply to damages caused by improper use due
to a non-respect of the operating instructions.
All pictures and drawings in these operating instructions are general illustrations. They do not
reflect the construction in detail.
The technical data and dimensions are without obligation, claims cannot be derived.
We reserve technical changes of the machine described below, without changing the
operating instructions.
All rights on these operating instructions, the added drawings and other documents remain to
W.S. Tyler. So are the rights on disposition, copying and passing on, including trademark
registering.

Transport
The W.S. Tyler Test Sieve Shaker Ro-Tap Model E is delivered completely assembled,
except the guide rods.
If not otherwise agreed, it is packed according to the packing directives, HPE, as defined by
The National Association of Wooden Instruments, Pallets, Export Packaging and The
Society of German engineering shops.

Observe the current valid national and international directives for accident prevention. Damage
caused by improper transport will invalidate any guarantee or replacement.
Warning
Improper lifting may cause bodily harm or material damage. Only lift the machine with the
suitable equipment and by qualified persons!
2

1. Put the machine on a stable, vibration free table.


Do not use a rubber support!
2. Screw the guide rods (3) into the drilled holes of the vibration
plate (1) and drive in the counter nuts (2) by the key.
Minimum of three test sieves (height 50 mm) and one
sieve pan is necessary when using guide rods with
lengths of 620 mm

Ro-Tap Model E dry


1. Put on the test sieve set (1) and fill the sieving material in
the upper test sieve.
2. Put on the cover (2) and fix it simultaneously with the
two tension nuts (3).

Connect the main plug, pay attention to the power


supply!

1.
2.
3.
4.

Ro-Tap Model E wet


Put on the sieve pan with outlet (1), the test sieve set (2) and fill
the sieving material in the upper test sieve.
Put on the cover (3) and fix it simultaneously with the two tension
nuts (4).
Slip the PVC- water hose over the wide spreading spray diffuser
and connect the discharge hose to the outlet of the sieve pan.
Fix the holding device and the separate control gear to the wall.

Connect the mains plug, pay attention to the power


supply!

The Model Ro-Tap E features an intermittent operation.


Every 10 seconds, the machine will pause for 3 seconds,
allowing the sample to settle.
Analysis Guide: If the smallest particle is 1 mm (USA #18)
or greater in size, use the COARSE analysis control
setting. For all other applications, use the FINE setting.
Each material application is different. Local analysis may
be required to determine which control setting will
produce the best results.

Starting and Operating

Set values
Actual values
Entry keys
left (-)
right (+)

Starting the machine


Switch on the machine with the main switch (located at the rear of the unit). All indicators on the front
panel will read 0.
Time
The sieving time is shown in minutes (99 minutes maximum) and appears in the indication field of
set values / actual values. The sieving time will countdown to 0. Without setting the sieving time (set
point 00) the machine operates continuously.
The sieving time can be fed by one pair of entry keys for each function. With the left key the set point
descends, with the right key it ascends. When pressing one of the keys for a longer moment, the
numbers pass quickly.
Analysis Settings
There are two amplitude analysis settings. One for coarse and the second for fine material.
The Model Ro-Tap E features an intermittent operation. Every 10
seconds, the machine will pause for 3 seconds, allowing the sample
to settle.
Analysis Guide: If the smallest particle is 1 mm (USA #18) or greater
in size, use the COARSE analysis control setting. For all other
applications, use the FINE setting.
Each material application is different. Local analysis may be
required to determine which
control setting will produce the best results.

Start/Stop
To start the machine, press the Start button. As the unit runs, the remaining analysis time will be
shown in the display window. To stop the machine, press the start button again.
.

Clamping system Easy Lock


1. Tension Nut
2. Guide Rod
3. Sieve Cover

Picture 1

Picture 2

Elevation adjustment: As illustrated in Picture no. 2 the hand has to be placed between the
locking ring and the tensioning wheel. Then pull the locking ring upwards, allowing the tension
nut to be moved easily up and down the guide rod.
Tensioning: As illustrated in Picture no. 1 the tension nuts have to be set on the sieve cover.
The tension nuts can then be screwed down for a tighter fit.

Technical data for the Ro Tap Model E


Test sieve shaker with electromagnetic drive and three-dimensional sieving action for
dry and wet sieving.
Operation voltage:
Frequency:
Power
consumption:
Control:
Weight:
Dimensions:
Emitted sound:

230 Volt or 110 Volt with transformer


50 Hertz or 60 Hertz
approx. 410 Volt-ampere with full charge
All-electronic
34 kg, without Test Sieves

345 x 285 x 705 mm


The emitted sound of the machine in action has been determined with
a comparative sound measurement according to DIN 45635-01 KI1.
The equivalent continuous sound level A is:
LpAeq = 78 (dB)

Ro Tap Model E
Ro-Tap Model E dry

Ro-Tap Model E wet

Basic machine Ro-Tap Model E dry

Basic machine Ro-Tap Model E wet

cover with inspection glass

cover with inspection glass and wide


spreading spray diffuser

1 pair of guide rods with tension- and counter nuts

1 pair of guide rods with tension- and counter nuts

1 spanner wrench
SW 27 DIN 894 WGBv
to fix the guide rods

1 spanner wrench
SW 27 DIN 894 WGB
to fix the guide rods

1 connection cable, 1,5m long, with EURO-plug and


appliance plug

Separate control gear with special plug type, holding


device with plugs and screws for wall fixing and 3 lin.m
PVC-water hose

Description Ro-Tap Model E (Dry Sieving)


Tension nut Easy Lock
Inspection glass
Cover
Rubber buffer
Test sieve set
Guide rod
Oscillation magnet
Rubber profile for vibration body
Vibration body
Rubber pads
Leaf spring
Base plate
Front panel with control board
Rubber ring
Sieve pan
Plug connection with main switch
and fuse box
18. Counter nut
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
16.
17.

Ro Tap Model E (Wet Sieving)


1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.

Tension nut Easy Lock


Inspection glass
Cover
Rubber buffer
Test sieve set
Guide rod
Oscillation magnet
Rubber profile for vibration body
Vibration body
Rubber pads
Leaf spring
Base plate
Separate control unit
Rubber ring
Wide spreading spray diffuser
Sieve pan with outlet
Plate with cable with screw fitting
Counter nut

List of spare parts

Ro-Tap Model E dry

Item No.

Piece

1
2

2
1
1
1
1
1
3

4
5
6
7
8
9
10
11
12
13

18
19

2
1
1
1
3
3
1
1
1
1
1
1
1
1
1
2
1

20

14
15
16
17

Ro-Tap Model E wet

Designation
Nuts for clamping system Easylock
Inspection glass without hole for machine cover (dry)
Inspection glass with hole for machine cover (wet)
Cover with inspection glass
Cover without inspection glass
Cover with inspection glass and wide spreading spray diffuser
Rubber buffer
Test sieves
Guide rods, clamping system Easylock, 660 mm long
Oscillation magnet
Rubber profile for vibration body
Vibration body
Rubberized pads
Leaf spring
Base plate
Separate control unit
Front panel with control board
Rubber ring for vibration body 204 / 160
Wide spreading spray diffuser
Wide spreading spray diffuser with inspection glass
Sieve pan with outlet
Plug connection with main switch and fuse box
Plate with cable with screw fitting
Counter nut
Precision fuse, 20x5 mm, 3,15 Ampere MT (not shown in the
drawing)
Rubber seal for cover (not shown in the drawing)

Article No.
00560129
00561499
00561507
00561521
00561514
00561545
66000074
00560154
65300016
00560441
68500312
00560014
68500231
68500311
00560169
68500015
00561374
00560489

68500033
65100000
00560434
9

Warranty
All functions of the machine are inspected and checked prior to its delivery.
The machine is warranted for 12 months.
*Test Sieves are excluded from warranty

W.S. Tyler is only liable for defects resulting from flaws or faults in material. The warranty
does not apply to damages caused by transport. Repairs resulting by improper handling or
wear due to operation are excluded from the warranty. The warranty is void, if interventions
such as variations or improper repairs are affected which are outside our control.

Maintenance and repair


In order to identify problems, the LED-display indicates for approximately 5 seconds, a
defect code, E nn will display in the window:

00 - 04
If this display appears, the machine has an electronic problem and W.S. Tyler should be
contacted immediately.

Please note that W.S. Tyler Test Sieve Shakers should only be repaired and serviced by
authorized dealers. Improper repairs may result in considerable dangers for the user.

W.S. Tyler
Particle Analysis, Filtration and Industrial Screening Products
8570 Tyler Blvd.
Mentor, Ohio 44060
Phone: 800-321-6188
Fax:
440-974-0921
E-Mail: wstyler@wstyler.com
The W.S. Tyler Test Sieve Shaker Ro-Tap Model E should be serviced at least
every 2 years!

10