Moeller HPL0211-2001/2002
Relays
Contactor Relays
Control Relays, Contactor Relays, Electronic Timing Relays, Electronic Safety Relays, Measuring and Monitoring Relays
04/001
Moeller HPL0211-2001/2002
Control relays
Contactor relays
AC and DC operated
AC and DC operated
System overview
Page
04/002
04/006
04/006
Accessories
Expansion units
04/008
04/007
Technical data
04/037
Dimensions
04/064
System overview
Page
04/004
04/010
04/010
04/010
04/012
04/012
04/012
04/014
Accessories
04/027
04/029
Actuating voltages
04/030
Tripping characteristics
04/032
Technical data
04/046
Dimensions
04/065
Relays
Contactor Relays
Control Relays, Contactor Relays, Electronic Timing Relays, Electronic Safety Relays, Measuring and Monitoring Relays
Overview
AC and DC operated
Page
DILET
Engineering
DILET11 on-delayed
timing relay
DILET70 multi-function relay
Page
04/022
Page
04/024
04/024
04/024
04/024
04/025
04/016
04/016
ETR4
ETR4-51 star-delta
timing relay
ETR4-69 multi-function relay
04/018
04/020
04/018
04/023
04/023
Technical data
04/054
04/025
Dimensions
04/067
04/025
04/023
04/023
04/023
04/023
Accessories
04/027
Tripping characteristics
04/033
Tripping characteristics
04/034
Technical data
04/053
Technical data
04/058
Dimensions
04/066
Dimensions
04/067
04/002
Moeller HPL0211-2001/2002
Relays
Contactor Relays
3
2
5
7
5
8
6
7
Moeller HPL0211-2001/2002
04/003
Basic units
AC or DC operated
Power supply
AC 100 (115) 240 V, 50/60 Hz
DC 24 V DC
DA 12 V DC
8 or 12 digital inputs
(2 inputs usable as analog inputs
[DC/DA variants only])
4 or 6 relay outputs (max. 10 A)
4 or 8 transistor outputs
LCD display, X variants without LCD
Screw fixing and snap fitting
Screw terminals
a Page 04/006
Fixing brackets
For optional screw fixing,
3 brackets per relay for EASY4...
minimum of 3 brackets per relay for
EASY6...
Basic units,
expandable EASY619/621
AC or DC operated
Power supply
AC 100 240 V, 50/60 Hz
DC 24 V DC
12 digital inputs
(2 inputs usable as analog inputs
[DC variants only])
6 relay outputs (max. 10 A)
8 transistor outputs
LCD display, X variants without LCD
Screw fixing and snap fitting
Screw terminals
a Page 04/008
a Page 04/006
a Page 04/008
a Page 04/008
Connection cable
Safe isolation between easy and PC
a Page 04/008
Expansion unit
I/O expansion
AC or DC operated
Power supply:
AC 100 240 V, 50/60 Hz
DC 24 V DC
12 digital inputs
6 relay outputs (max. 10 A)
8 transistor outputs
Screw fixing and snap fitting
Screw terminals
a Page 04/006
Coupling unit
a Page 04/007
Connection cable
e.g. NYM 3 x 1.5 mm2
a Page 04/008
Relays
Contactor Relays
04/004
Contactor Relays, Electronic Timing Relays
System Overview
Relays
Contactor Relays
DILER
DILR
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
04/005
Suppressors
All contactor relays with DC operated
coils have an integral suppressor circuit
Suppressors for contactor relays with
AC operated coils
Relays
Contactor Relays
Basic units
AC or DC operated
Magnet systems
AC 12 480 V, 50, 60, 50/60 Hz
0.8 1.1 Uc
25 VA/4.6 VA
DC 12 220 V DC
0.85 1.1 Uc
2.6 W/2.6 W
Maximum of eight contacts
Interlocked opposing contacts
Modular system
Screw fixing and snap fitting
Finger proof
Screw terminals
a Page 04/026
3, 4
a Page 04/027
a Page 04/010
a Page 04/010
Suppressors
RC suppressor
Varistor suppressor
Free-wheel diode suppressor
a Page 04/026
Amplifier modules
With and without integral
suppressor circuits
Plug-in type
Separate mounting
a Page 04/012
a Page 04/026
a Page 04/012
a Page 04/010
Auxiliary contact modules
2-pole
Plug-in type
Interlocked opposing contacts
a Page 04/012
04/006
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Description
Type
Article no.
Price
See Price List
Std. pack
Basic units
24 V DC,
retentive
DEL
ESC
EASY412-DC-R
202403
EASY412-DC-RC
202404
EASY412-DC-RCX
221596
EASY412-DC-TC
207808
ALT
OK
12 V DC,
retentive
EASY412-DC-TCX
212307
EASY618-DC-RC
224472
EASY619-DC-RC
224473
EASY619-DC-RCX
224474
EASY620-DC-TC
212309
EASY621-DC-TC
218719
EASY621-DC-TCX
212311
EASY412-DA-RC
224471
1 off
04/007
Moeller HPL0211-2001/2002
Price
See Price List
Std. pack
Basic units
115/230 V AC
115/230 V AC,
retentive
EASY412-AC-R
202405
1 off
EASY412-AC-RC
202406
EASY412-AC-RCX
212308
EASY618-AC-RC
212310
EASY619-AC-RC
218721
EASY619-AC-RCX
212312
12 digital inputs
8 transistor outputs
With connector
12 digital inputs, 115/230 V AC
6 relay outputs
With connector
Coupling unit for connecting to an EASY619/621 basic unit
Terminals for remote expansion, up to 30 m to/from the expansion
unit
With connector
EASY620-DC-TE
212313
EASY205-ASI
221598
1 off
EASY204-DP
212316
1 off
9-pole (pins), comes as a kit without cable, for connection of the data
cable
Metallised insulated housing
Maximum transfer rate 12 MBit/s
Built-in switch (accessible from the outside) for the bus termination
resistances
Terminal block for two cables, optionally with straight
or 90 angled cable entry
Suitable for EASY204-DP
Twisted pair cable, 2 X 0.64 mm2, length: 100 m
ZB4-209-DS2
206982
ZB4-209-DS3
217820
1 off
Expansion units
24 V DC
115/230 V AC
Coupling unit
PROFIBUS DP
Accessories for DP
PROFIBUS DP
bus connector plug
PROFIBUS DP
bus connector plug
PROFIBUS DP
data cable
1 off
EASY618-AC-RE
212314
EASY200-EASY
212315
ZB4-900-KB1
206983
Relays
Contactor Relays
Description
04/008
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Description
Accessories
Software
Memory card
Connection cable
Input-/output simulator
Fixing bracket
Coupling piece
Telescopic adapter
Type
Article no.
Price
See Price List
Std. pack
EASY-SOFT
202407
EASY-M-8K
202408
EASY-M-16K
212317
EASY-PC-CAB
202409
EASY412-DC-SIM
212318
EASY412-DC-SIM-NA
222566
1 off
ZB4-101-GF1
061360
9 off
EASY-LINK-DS
221607
M22-TA
226161
1 off
EASY400-POW
212319
1 off
10 off
04/009
Moeller HPL0211-2001/2002
Price
See Price List
Std. pack
Documentation
Manual for the Easy control relay
German
English
French
Italian
Spanish
Brief introduction to the Easy control relay
German
English
French
Italian
Spanish
AWB2528-1304-D
205375
AWB2528-1304-GB
205481
AWB2528-1304-F
205482
AWB2528-1304-I
205483
AWB2528-1304-E
205484
1 off
AWB2528-1316-D
205376
AWB2528-1316-GB
205485
AWB2528-1316-F
205486
AWB2528-1316-I
205487
AWB2528-1316-E
205488
1 off
Relays
Contactor Relays
Description
04/010
Moeller HPL0211-2001/2002
Relays
Contactor Relays
M = Make
B = Break
Rated operational
current Ie
AC-15
220 V
380 V
230 V
400 V
240 V
415 V
Conv.
therm.
current
Ith
6
3
10
Type
Article no.
Circuit symbol
A1 13 23 33 43
DC operation
Price
See Price
List
Circuit symbol
40E
DILER-40(230V50HZ)
051759
31E
DILER-31(230V50HZ)
051768
5 off
A2 14 24 34 44
3M
1B
A1 13 21 33 43
2B
A1 13 21 31 43
61
1B
2M
22E
DILER-22(230V50HZ)
051777
42E
33
24
02DILE
010240
51E
42
33
11DILE
010224
60E
51
42
20DILE
010208
5 off
4B
53 63
10
51
42
33
51 61 71 81
3B
53 61 71 81
2M
2B
53 61 71
44E
35
26
04DILE
010256
83
54 62 72
84
53E
44
35
13DILE
002397
62E
53
44
22DILE
010288
62
53
54 62 74 84
53 63 73 83
80E
71
62
54 64 74 84
2 M 2)
Notes
2 B 2)
1)
2)
02DILE
010240
51E
42
11DILE
010224
53 63
60E
51
20DILE
010208
57 65
51
42
11DDILE
049824
57 65 71
83
58 66 72
84
5 off
51 61 71 81
44E
35
04DILE
010256
53 61 71 81
53E
44
13DILE
002397
62E
53
22DILE
010288
71E
62
31DILE
048912
80E
71
40DILE
010304
62
53
22DDILE
049823
54 62 72 82
71E
53 61 73 83
33
52 62 72 82
54 62 72 82
4M
42E
5 off
58 66
1M
1B
DILER-22-G(24VDC)
010042
54 62
11DDILE
049824
52 62 72 82
3M
22E
54 64
57 65
51 61
53 61
58 66
5 off
DILER-31-G(24VDC)
010157
31E
21 33 43
A1 13 21 31 43
54 64
4-pole
DILER-40-G(24VDC)
010223
40E
52 62
53 61
1 B 2)
A2 14 22 32 44
54 62
1 M 2)
Notes
Std. pack
A2 14 22 34 44
52 62
1M
Price
See Price
List
A2 14 24 34 44
A2 14 22 32 44
2B
4
2
10
A1 13 23 33 43
A1 13
A2 14 22 34 44
2M
Type
Article no.
Std. pack
62
53
44
31DILE
048912
40DILE
010304
22DDILE
049823
53 61 71
83
54 62 72
84
53 61 73 83
54 62 74 84
53 63 73 83
54 64 74 84
57 65 71
83
58 66 72
84
Relays
Contactor Relays
AC operation
Contacts
04/011
Moeller HPL0211-2001/2002
5 off
Version E combinations
correspond to EN 50 011 and
are to be preferred;
other combinations correspond
to EN 50 005.
Accessories
Page
1 Suppressor
Other accessories
04/026
04/026
04/012
Moeller HPL0211-2001/2002
Relays
Contactor Relays
M = Make
B = Break
Rated operational
current Ie
AC-15
220 V
380 V
230 V
400 V
240 V
415 V
Conv.
therm.
current
Ith
6
4
16
Type
Article no.
Circuit symbol
A1 13 23 33 43
DC operation
Price
See Price
List
Std. pack
Type
Article no.
Price
See Price
List
DILR40(230V50HZ)
043756
31 E
DILR31(230V50HZ)
043768
DILR31-G(24VDC)
048532
22 E
DILR22(230V50HZ)
043780
DILR22-G(24VDC)
048526
42 E
33
24
02DIL
098145
51 E
42
33
11DIL
010345
11DIL
010345
60 E
51
42
20DIL
012718
20DIL
012718
1 off
DILR40-G(24VDC)
048537
1 off
A2 14 24 34 44
3M
1B
2M
2B
A1 13 21 33 43
A2 14 22 34 44
A1 13 21 31 43
Notes
Std. pack
Relays
Contactor Relays
AC operation
Contacts
04/013
Moeller HPL0211-2001/2002
A2 14 22 32 44
2B
6
4
16
51 61
5 off
02DIL
098145
5 off
52 62
1M
1B
2M
53 61
54 62
53 63
54 64
4-pole
4B
16
51 61 71 81
44 E
35
26
04DIL
015091
53 E
44
35
13DIL
017464
13DIL
017464
62 E
53
44
22DIL
019837
22DIL
019837
71 E
62
53
31DIL
010752
31DIL
010752
80 E
71
62
40DIL
022210
40DIL
022210
51
42
33
TPE11DIL
002279
51
42
33
TPD11DIL
002280
TPD11DIL
002280
51
42
33
TPEH11DIL
046924
TPEH11DIL
046924
51
42
33
TPDH11DIL
046925
TPDH11DIL
046925
40 E
31 E
22 E
VDIL(230V50HZ)
043825
5 off
04DIL
015091
5 off
52 62 72 82
1M
3B
2M
2B
53 61 71
83
54 62 72
84
3M
1B
53 61 73 83
4M
53 61 71 81
54 62 72 82
54 62 74 84
53 63 73 83
54 64 74 84
55 67
1 off
TPE11DIL
002279
1 off
56 68
Off-delayed
1M
1B
10
65 57
66 58
10
55 67
56 68
Off-delayed
1M
1B
10
65 57
66 58
E2
Note
1)
1 off
V-GDIL(24VDC)
048562
1 off
Accessories
Page
1 Amplifier module
Other accessories
04/026
04/026
04/014
Moeller HPL0211-2001/2002
Relays
Contactor Relays
M = Make
B = Break
Rated operational
current Ie
AC-15
220 V
380 V
230 V
400 V
240 V
415 V
Conv.
therm.
current
Ith
Type
Article no.
Circuit symbol
13 21 35 47
DC operation
Price
See Price
List
Std. pack
Type
Article no.
4B
A1 13 23 33 47 51 61 71 85
Notes
Std. pack
Distinctive number
22
DILR22D(230V50HZ)
043792
1 off
DILR22D-G(24VDC)
048542
A2 14 22 36 48
4M
Price
See Price
List
Relays
Contactor Relays
AC operation
Contacts
04/015
Moeller HPL0211-2001/2002
44
DILR44D(230V50HZ)
043803
DILR44D-G(24VDC)
048547
53
DILR53D(230V50HZ)
043814
DILR53D-G(24VDC)
048552
1 off
A2 14 24 34 48 52 62 72 86
5M
3B
A1 13 23 33 47 53 61 71 85
A2 14 24 34 48 54 62 72 86
Accessories
Page
1 Amplifier module
Other accessories
04/026
04/026
04/016
Moeller HPL0211-2001/2002
Conv.
therm.
current
Ith
Time range
Price
See Price
List
Available functions1)
Notes
Std.
Potential-free contact
Do not apply voltage!
1.5 30 s
0.05 1 s
0.15 3 s
0.5 10 s
3 60 s
0.15 3 min
0.5 10 min
3 60 min
0.15 3 h
0.5 10 h
3 60 h
DILET11-30-A
048878
DILET11-M-A
048886
DILET11-30-W
048904
DILET11-M-W
048891
1 off
11
1 off
Type suffix
15
A1
11
16
A2
-A
18
-W
-A
-W
DILET70-A
048893
DILET70-W
048899
1 off
Z1
Z2
15
A1
A2
Z1
Notes
60 min
42 min
7
16
18
Z2
Y1
A1
Y2
A2
1)
15
16
Connection to
Y1/Y2
Z1/Z2
250 m
50 m
Accessories:
Sealable shroud
Remote potentiometer
Page
04/027
04/028
18
Flow diagrams
LED display
11 On-delayed
Time t not running
Contact 15 18 closed
12 Off-delayed
Y1-Y2
Y1-Y2
15-18
15-18
Time t running
Contact 15 18 closed
Time t running
Contact 15 18 open
A1-A2
A1-A2
A1-A2
15-18
LED
Calculated as follows:
Time requiredx10
--------------------------------------------------------------------- = Setting on time scale
Time range of timing relay
Actuating voltage
printed on unit
V DC
V AC
24 240
24 240,
50/60 Hz
346 440
50/60 Hz
Voltage tolerance:
V DC
V AC
16.8 288
20.4 264
294.1 484
Setting example
Time range of timing relay
Time required
Setting required on time scale
LED
22 Fleeting contact on
de-energization
LED
42 Flashing
A1-A2
A1-A2
42 minx10
------------------------------ = 7
60 min
Relays
Contactor Relays
Relays
Contactor Relays
Rated operational
current Ie
AC-11
220V
380V
230V
400V
240V
440V
04/017
Moeller HPL0211-2001/2002
15-18
A1-A2
15-18
t
Y1-Y2
15-18
LED
LED
LED
81 Pulse generating
ON-OFF function
82 Pulse shaping
A1-A2
A1-A2
A1-A2
15-18
t
0.5 s
Y1-Y2
15-18
LED
t
LED
15-18
OFF
ON
OFF
LED
04/018
Moeller HPL0211-2001/2002
Conv.
therm.
current
Ith
220V
230V
240V
380V
400V
440V
Time range
Price
Article no.
Article no.
See Price
List
0.05 1 s
0.15 3 s
0.5 10 s
1.5 30 s
5 100 s
15 300 s
1.5 30 min
15 300 min
1.5 30 h
5 100 h
ETR4-11-A
031882
3 60 s
ETR4-51-A
031884
See Price
List
ETR4-11-W
031883
Available functions1)
Available functions 1)
Terminal markings
to EN 50 042
Terminal markings
to EN 50 042
Std.
pack
1 off
11
Type suffix
Actuating voltage
printed on unit
V DC
V AC
24 240
24 240,
50/60 Hz
346 440
50/60 Hz
Voltage tolerance:
V DC
V AC
16.8 288
20.4 264
294.1 484
15
A1
-A
16
A2
18
-W
ETR4-51-W
031885
1 off
-A
-W
51
17
A1
18
A2
Multi-function relay
3
0.05 1 s
0.15 3 s
0.5 10 s
1.5 30 s
5 100 s
15 300 s
1.5 30 min
15 300 min
1.5 30 h
5 100 h
ETR4-69-A
031891
ETR4-69-W
031887
1 off
16
A2
1)
Notes
Flow diagrams
11 On-delayed
28
15
A1
B1 A1
18
A2
15
16
Connection to
B1
250 m
50 m
Accessories:
Screw adapter
18
Page
04/028
12 Off-delayed
A1-A2
A1-A2
B1
15-18
B1
15-18
15-18
t
Power LED
Power LED
Power LED
15-18
Power LED
Rel LED
Rel LED
Rel LED
Rel LED
22 Fleeting contact on
de-energization
42 Flashing
81 Pulse generating
A1-A2
A1-A2
A1-A2
15-18
A1-A2
B1
t
82 Pulse shaping
15-18
Power LED
0.5 s
B1
15-18
15-18
Power LED
LED
t
Power LED
Rel LED
Rel LED
Rel LED
ON-OFF function
51 Star-delta
A1-A2
A1-A2
17-18
17-28
t
tu
15-18
OFF
ON
OFF
Power LED
Rel LED
Power LED
LED
LED
Relays
Contactor Relays
Relays
Contactor Relays
Rated operational
current Ie
AC-15
04/019
Moeller HPL0211-2001/2002
04/020
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Rated operational
current Ie
AC-11
220 V
380 V
230 V
400 V
240 V
440 V
Conv.
therm.
current
Ith
Time range
Notes
Std. pack
Multi-function relay
With two changeover contacts and connection for remote potentiometer.
Can be converted to two timed contacts or one non-delayed contact and
one timed contact.
ETR4-70-A
3
3
6
0.05 1 s
031888
0.15 3 s
0.5 10 s
1.5 30 s
5 100 s
15 300 s
1.5 30 min
15 300 min
1.5 30 h
5 100 h
1 off
Type suffix
-A
Actuating voltage
printed on unit
V DC
V AC
24 240
24 240,
50/60 Hz
Voltage tolerance:
V DC
V AC
16.8 288
20.4 264
Connection to
B1
Z1/Z2
250 m
50 m
Accessories
Screw adapter
Remote potentiometer
Page
04/027
04/028
04/021
Moeller HPL0211-2001/2002
Terminal markings
to EN 50 042
Z1
15
X1
A2
16
25
18
26
28
Terminal markings
to EN 50 042
Z2
A1
11 On-delayed
Available functions
12 Off-delayed
Z2
B1
A1
X1
A2
15
16
25
18
26
28
A1-A2
A1-A2
A1-A2
15-18
(25-28)
B1
B1
15-18
(25-28)
Power LED
Power LED
Z1
15-18
(25-28)
Power LED
Power LED
42 Flashing
81 Pulse generating
82 Pulse shaping
A1-A2
A1-A2
A1-A2
A1-A2
15-18
(25-28)
15-18
(25-28)
B1
B1
0,5 s
15-18
(25-28)
15-18
(25-28)
Power LED
Power LED
Power LED
Power LED
Rel 1,2 LED
ON-OFF function
A1-A2
15-18
(25-28)
OFF
ON
OFF
Power LED
Rel 1,2 LED
Z1
Z2
A1
X1
11 On-delayed
A2
Available functions
16
21
15
18
22
A1-A2
t
Z1
Z2
B1
A1
X1
24
Terminal markings
to EN 50 042
12 Off-delayed
A2
21
15
16
18
22
24
A1-A2
A1-A2
A1-A2
15-18
B1
B1
15-18
21-24
15-18
t
21-24
Power LED
21-24
Power LED
Rel 1 LED
Rel 2 LED
Rel 1 LED
Rel 2 LED
42 Flashing
81 Pulse generating
15-18
Power LED
Rel 1 LED
Rel 1 LED
Rel 2 LED
Rel 2 LED
A1-A2
21-24
Power LED
82 Pulse shaping
A1-A2
A1-A2
A1-A2
15-18
B1
B1
0.5 s
15-18
t
Power LED
15-18
t
21-24
21-24
Power LED
21-24
Rel 1 LED
Rel 2 LED
Power LED
Rel 1 LED
21-24
Power LED
Rel 2 LED
Rel 1 LED
Rel 1 LED
Rel 2 LED
ON-OFF function
A1-A2
15-18
(25-28)
OFF
ON
OFF
Power LED
Rel 1,2 LED
Rel 2 LED
Relays
Contactor Relays
A2/X1 linked
a Two timed contacts
Available functions
04/022
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Safety category
Function
Electronic safety relays are used for monitoring safetyrelated control systems. The requirements for the
electrical equipment of machines are specified in
IEC/EN 60 204. EN 954-1 stipulates that machine
users must carry out a risk assessment of machines
and implement a control system that meets the
requirements of safety categories 1, 2, 3, or 4.
Construction
The electronic safety relays consist of a power section,
the electronics and two redundant relays with
interlocked opposing contacts for the enabling- and
signalling paths.
Stop category
Single/dual-channel construction
IEC/EN 60 204-1 stipulates two relevant stop
categories for stopping in the event of an emergency:
Stop category 0: stopping by means of immediate
removal of the power supply to the machine
actuators.
Stop category 1: controlled stopping with power
available to the machine actuators to achieve the
stop. Power is not removed until the stop is
achieved.
Emergency-Stop
circuits
Monitoring of contact
mats/safety mats, and
safety bumpers
Protective guard
monitoring
Monitoring of
two-hand controls
04/023
Moeller HPL0211-2001/2002
Safety
category to
EN 954-1
Enabling path
to
IEC/EN 60 204
Type
Article no.
Price
See Price List
Std. pack
ESR3-NO-31(230V)
214615
24 V DC 50/60 Hz
Single-channel
ESR4-NO-31
214612
24 V DC 50/60 Hz
Dual-channel
SR4-NO-21
214613
24 V DC
34)/4 5)
ESR4-NV3-30
214616
24 V DC
34)/4 5)
ESR4-NV30-306)
214617
24 V DC
Dual-channel
delayed 1.5 30 s8)
34)/4 5)
ESR4-NT30-307)
225011
Dual-channel
ESR4-NM-21
214619
1 off
24 V DC 50/60 Hz
Dual-channel
ESR4-NZ-21
214620
1 off
Non-delayed
42)
43)
ESR4-NE-42
214614
1 off
Off-delayed
tA = 3 s
42)
ESR4-VE3-42
214618
1 off
1 off
Two-hand relay1) 9)
24 V DC
Notes
1)
2)
3)
4)
5)
6)
7)
8)
9)
Relays
Contactor Relays
Stop category
0
1
04/024
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Description
Description
Description
Adjustable current
measuring range
I~/I=
3 30 mA
10 100 mA
0.1 1 A
0.3 1.5 A
15A
3 15 A
Monitoring
voltage
200 500 V AC
Circuit symbol
Supply
voltage
Type
Price
Article no.
See Price
List
Std.
pack
24 240 V AC/DC
EMR4-I1-2-A
221781
24 240 V AC/DC
EMR4-I15-2-A
221782
220 240 V AC
EMR4-I15-2-B
221783
Supply
voltage
Type
Article no.
Std.
pack
200 500 V AC
EMR4-F500-2
221784
1 off
Supply
voltage
Type
Article no.
160 300 V AC
EMR4-W500-2-C
221785
300 500 V AC
EMR4-W500-2-D
221786
300 500 V AC
EMR4-W580-2-D
221787
Circuit symbol
Supply
voltage
Type
Article no.
L1 L2 L3
380 415 V 50 Hz
EMR4-A400-1
221788
B1 B2 B3
15
25
1 off
C
A1
A2 16 18 26 28
Circuit symbol
L1 L2 L3
1115
2125
Monitoring
voltage
Adjustable by
Circuit symbol
L1 L2 L3
A1
15
A2 16 18 26 28
Monitoring
voltage
25
15
16 18
Price
See Price
List
Std.
pack
1 off
Price
See Price
List
Std.
pack
1 off
04/025
Moeller HPL0211-2001/2002
Response
sensitivity range
5 100 kO
Circuit symbol
C Max.Min.
A1
Supply
voltage
11
See Price
List
EMR4-N500-2-B
221790
EMR4-N500-2-A
221791
Std.
pack
1 off
A2 12 14
220 240 V AC
250 O 500 k O
24 240 V AC/DC
Description
Insulation
resistance range
Article no.
EMR4-N100-1-B
221789
250 O 500 k O
10 110 kO
Price
220 240 V AC
Type
Circuit symbol
L+ L
15
Supply
voltage
Type
Article no.
Price
See Price
List
24 240 V AC/DC
EMR4-RDC-1-A
221792
1 off
24 240 V AC/DC
EMR4-RAC-1-A
221793
1 off
Std.
pack
R<
10 110 kO
A1
A2 16 18
15
R<
A1
B2
A2 16 18
Mounting width
Type
Article no.
Price
See Price
List
22.5 mm
EMR4-PH22
221795
1 off
45 mm
EMR4-PH45
221794
1 off
Std.
pack
Relays
Contactor Relays
Description
04/026
Moeller HPL0211-2001/2002
AC-15
DC1)
240/415 V 220 V
Relays
Contactor Relays
1.5/1
Type
Article no.
Price
See Price
List
DILR..
VS1DIL
055480
1 off
DILR..
VS2DIL
057853
1 off
As
required
ETS4-VS3
083094
1 off
DILE...
TDDILE24
090200
1 off
DILE...
VGDILE48
010320
VGDILE250
010336
VGDILE415
010463
10 off
DILR...
VGBDIL24
076837
VGBDIL48
071609
VGBDIL250
071610
VGBDIL415
071611
10 off
For AC operated
5060 Hz and DC
operated contactor
relays
DILE...
RCDILE48
044264
RCDILE250
046320
RCBDIL48
067345
RCBDIL250
069718
RCBDIL415
072091
1 off
For AC operated
5060 Hz contactor
relays Note drop-out
delay
FDBDIL
074464
10 off
For DC operated
contactor relays
Note drop-out delay
Std. pack
V DC/mA
With integral
suppressor circuit
For use
with
contactor
relays
0.2
24/11
24/11
A0
A2
A1
A2
A0
A2
A1
A2
21
13
22
14
Off-delay mechanism
24/
Suppressors
Varistor suppressor
24 48 V
110 250 V
A1
A2
380 415 V
12 24 V
24 48 V
110 250 V
380 415 V
RC suppressors
24 48 V
110 250 V
A1
A2
24 48 V
DILE...
DILR...
110 250 V
380 415 V
Free-wheel diode suppressors
12 250 V
A1
DILR...
A2
Notes
1)
Moeller HPL0211-2001/2002
04/027
Type
Article no.
DILE...
DILET...
V0DILE
026634
50 off
DILR...
ETR4
V0DIL
010772
20 off
DILR...
ETR4
V5/15DIL
013145
10 off
DILE...
MVDILE
010113
5 off
DILE...
...DILE
DILR
...DIL
BT480
052785
100 off
DILE...
DILET...
DILR...
BT483
059904
100 off
DILE...
DILET...
HDILE
010482
1 off
TPE(H)
TPD(H)
PL-DILT
036073
5 off
Std. pack
Spacers
For arranging contactor
relays and timing relays in
combinations
Mechanical interlock
Paralleling link
For auxiliary contacts
Sealable shrouds
Transparent
Relays
Contactor Relays
Price
See Price
List
04/028
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Type
Article no.
DILET...
ETR4-70
RR-10
031344
1 off
ETR4
CS-TE
095853
1 off
...DIL
KG10
022256
500 off
8 x 20 mm
...DILE, DILER
...DIL, DILR
KG20
091075
500 off
8 x 17.5 mm
Colour: white
DIL...
XGKS-Z
207508
500 off
Sheet of labels
7.5 x 17 mm
XGKS, XGKS-Z
KG20
XGKE-GE
207517
25 off
1 off = 1 sheet
240 labels per sheet
For inscription
using laser
printer, plotter,
transparencyprinter,
photocopier
DIL...
XGKA-Z
207513
250 off
AC
DILR
1 off
DC
DILR
J-DIL00M(230V50HZ)
043833
G-DIL00M(24VDC)
048557
Price
See Price
List
Std. pack
Screw adapter
Adapter with
fixing stud
Individual coils
1 off
04/029
Moeller HPL0211-2001/2002
DILR
Make contact
0
1,9
2,78 mm
Break contact
4,3 5,7 mm
Break contact
0 0,95
2,78 mm
DILER-DC
Early-make contact
Make contact
0
1,9
2,85 mm
Late-break contact
2,5
5,7 mm
2,4
5,7 mm
5,6
5,7 mm
Break contact
0 0,95
2,85 mm
...DIL
Make contact
...DILE
Make contact
7 mm
Break contact
0
1,9
Break contact
0 0,89
2,78 mm
2,78 mm
3,9
7 mm
TP...11DIL
Make contact
...DDILE
Early-make contact
0
1,06
2,88 mm
Late-break contact
Make contact
Break contact
4,1
5,7 mm
Break contact
1,86
2,88 mm
1,9
2,78 mm
0 0,89
2,78 mm
0 1,7
5,7 mm
Relays
Contactor Relays
Make contact
04/030
Moeller HPL0211-2001/2002
Relays
Contactor Relays
AC
DILER-40(...)
DILER-31(...)
DILER-22(...)
DILR40(...)
DILR31(...)
DILR22(...)
Article no. 1)
Article no. 1)
Article no. 1)
Article no.1)
Article no. 1)
Article no.1)
Standard voltages
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
12V50Hz
24V50Hz
48V50Hz
240V50Hz
24V60Hz
110V60Hz
115V60Hz
42V50Hz,
48V60Hz
110V50Hz,
120V60Hz
190V50Hz,
220V60Hz
220V50Hz,
240V60Hz
230V50Hz,
240V60Hz
380V50Hz,
440V60Hz
400V50Hz,
440V60Hz
415V50Hz,
480V60Hz
24V50/60Hz
42V50/60Hz
110V50/60Hz
230V50/60Hz
066169
010094
010190
010478
010110
010254
010270
051755
066170
010251
010044
010300
010267
010172
010204
051764
066171
010344
010201
010138
010497
010265
010211
051773
025066
055915
017947
027439
096255
043752
029810
058286
022691
032183
010826
043764
077267
091505
017943
084386
093878
043776
051756
051765
051774
043753
043765
043777
051757
051766
051775
043754
043766
043778
051758
051767
051776
043755
043767
043779
051759
051768
051777
043756
043768
043780
051760
051769
051778
043757
043769
043781
051761
051770
051779
043758
043770
043782
051762
051771
051780
043759
043771
043783
021924
033459
021961
052725
021594
029869
021624
052509
021704
029433
021871
052508
022693
039304
091509
052762
027437
044048
096253
052761
058284
060657
065403
052726
Non-standard voltages
(i.e. voltages other than the
standard voltages listed above)2)
...V50Hz(12600V)
...V60Hz(12600V)
Price
See Price List
Price
See Price List
Price
See Price List
986763
989136
991507
993880
934554
936927
DC
DILER-40-G(...)
DILER-31-G(...)
DILER-22-G(...)
DILR40-G(...)
DILR31-G(...)
DILR22-G(...)
Standard voltages
Article no. 1)
Price
See Price List
Article no. 1)
Price
See Price List
Article no. 1)
Price
See Price List
Article no.1)
Price
See Price List
Article no. 1)
Price
See Price List
Article no.1)
Price
See Price List
12V DC
24V DC
48V DC
60V DC
110V DC
220V DC
079711
010223
010255
010271
010287
010303
079761
010157
010205
010221
010253
010269
080728
010042
010346
010499
010043
010091
048537
048538
048539
048535
048536
048532
048533
048534
048530
048531
048526
048527
048528
048529
048525
Non-standard voltages
(i.e. voltages other than the
standard voltages listed above)2)
...VDC(12250V)
Price
See Price List
Price
See Price List
Price
See Price List
915590
915591
915592
Notes
1)
2)
To obtain the article number for ordering, read under selected type and actuating voltage from the table above.
For non-standard voltages, state the actuating voltage selected from the range (......V) shown.
04/031
Moeller HPL0211-2001/2002
AC
DILR22D(...)
DILR44D(...)
DILR53D(...)
VDIL(...)
J-DIL00M(...)
Individual coil
Article no.1)
Article no. 1)
Article no.1)
Article no.1)
Article no.1)
Standard voltages
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
24V50Hz
48V50Hz
240V50Hz
24V60Hz
115V60Hz
42V50Hz,
48V60Hz
110V50Hz,
120V60Hz
190V50Hz,
220V60Hz
220V50Hz,
240V60Hz
230V50Hz,
240V60Hz
380V50Hz,
440V60Hz
400V50Hz,
440V60Hz
415V50Hz,
480V60Hz
24V50/60Hz
42V50/60Hz
110V50/60Hz
230V50/60Hz
013207
041683
096261
015580
084396
043788
072533
010836
065414
074906
053549
043799
055923
084399
044058
058296
032193
043810
053536
055493
053115
053659
052241
043821
000079
023809
066693
099744
043837
043829
043789
043800
043811
043822
043830
043790
043801
043812
043823
043831
043791
043802
043813
043824
043832
043792
043803
043814
043825
043833
043793
043804
043815
043834
043794
043805
043816
043835
043795
043806
043817
043836
010834
027445
079650
052760
070160
086771
048803
052838
048804
070161
027447
052961
053217
055218
051165
054487
002452
011944
085506
051352
Non-standard voltages
(i.e. voltages other than the
standard voltages listed above)2)
...V50Hz(12415V)
...V50Hz(12600V)
...V60Hz(12415V)
...V60Hz(12600V)
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
974904
977277
944057
946430
922701
925074
903184
903183
910098
910099
DC
DILR22D-G(...)
DILR44D-G(...)
DILR53D-G(...)
V-GDIL(...)
G-DIL00M(...)
Standard voltages
Article no.1)
Price
See Price List
Article no. 1)
Price
See Price List
Article no.1)
Price
See Price List
Article no.1)
Price
See Price List
Article no.1)
Price
See Price List
24VDC
48VDC
60VDC
110VDC
220VDC
048542
048543
048544
048540
048541
048547
048548
048549
048545
048546
048552
048553
048554
048550
048551
048562
048563
048564
048560
048561
048557
048558
048559
048555
048556
Non-standard voltages
(i.e. voltages other than the
standard voltages listed above)2)
...VDC(12250V)
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
Price
See Price List
915578
915579
915580
915545
910110
Notes
1)
2)
To obtain the article number for ordering, read under selected type and actuating voltage from the table above.
For non-standard voltages, state the actuating voltage selected from the range (......V) shown.
Relays
Contactor Relays
DILR Complete Units, VDIL Mechanical Latching Module, J-DIL Individual Coil
Actuating Voltages
04/032
Moeller HPL0211-2001/2002
DILR(AC-15)
a = Make contact
b = Break contact
Relays
Contactor Relays
X 106
2000
20
10
b
1000
5
a
2
500
1
0.5
0.2
200
AC-15
AC-15
240 V
240 V
0.1
0.01
0.02
0.05
0.1
0.2
0.5
100
10 A
9 10 A
Ie
Ie
DILR(DC-131))
DILR(DC-131))
X 106
2000
20
10
1000
5
2
500
1
DC-13
DC-13
0.5
200
220 V
220 V
L
0.2
L
Q 50 ms
R
Q 50 ms
R
100
0.1
0.01 0.02
0.05
0.1
0.2
0.5
10 A
10 A
Ie
Ie
DILR(DC-131))
DILR(DC-131))
5000
106
2000
20
10
1000
500
1
DC-13
0.5
0.2
200
24 V
L
R
L
Q 50 ms
R
50 ms
0.1
0.01 0.02
24 V
100
0.05
0.1
0.2
0.5
10 A
le
Notes
1)
10 A
Ie
Moeller HPL0211-2001/2002
04/033
Relays
Contactor Relays
x 106
20
10
5
2
1
0.5
AC-15
0.2
240 V
0.1
0.01 0.02
0.05
0.1
0.2
0.5
10 A
Ie
DILET(AC-11)
Component lifespan (operations)
Ie = Rated operational current
x 10 6
20
10
5
2
1
0.5
AC-11
0.2
240 V
0.1
0.01
0.02
0.05
0.1
0.2
0.5
10 A
e
04/034
Moeller HPL0211-2001/2002
a
b
Relays
Contactor Relays
c
d
e
f
tm
<t
Function at undercurrent, UC
a Supply voltage on A1-A2
b Hysteresis (reset value) undercurrent, UC
c Response threshold for measuring the current
d Timed contact 1: 15-18, 15-16
e Timed contact 2: 25-28, 25-26
a
b
c
e
tm
<t
L1, L2, L3
L1, L3, L2
L1, L2, L3
a
b
L2, L3
L1 d
c
EMR4-W... phase monitoring relay
On-delayed fault indication: function
a Supply voltage on A1-A2
b>U
c Hysteresis + 5 %
d Monitored voltage (rated voltage) L1, L2, L3
e Hysteresis 5 %
f<U
e Timed contact 1: 15-18, 15-16
h Timed contact 2: 25-28, 25-26
a
b
c
d
e
f
h
t
<t
Off-delayed fault indication: function
a Supply voltage on A1-A2
b>U
c Hysteresis + 5 %
d Monitored voltage (rated voltage) L1, L2, L3
e Hysteresis 5 %
f<U
e Timed contact 1: 15-18, 15-16
h Timed contact 2: 25-28, 25-26
a
b
c
d
e
f
h
t
t
<t
Moeller HPL0211-2001/2002
04/035
L1, L3, L2
L1, L2
L3
L1
L2
L3
L1, L2
L3
d L1/L3 > I Asym. I
e
t
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
a
b
c
d
e
a
b
c
d
e
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
f
t
a
b
c
d
e
f
1.6 Rx
Rx
g
h
tT
a
b
c
1.6 Rx
Rx
e
tT
Relays
Contactor Relays
04/036
Moeller HPL0211-2001/2002
Relays
Contactor Relays
U
[V]
DC load (resistive)
U
[V]
300
300
200
200
100
80
60
50
40
30
100
80
60
20
20
10
40
30
0.1
0.2
0.5
10
10
0.1
0.2
0.5
10
[A]
[A]
Contact life
1.0
Ops.
0.9
106
8
6
0.8
4
0.7
0.6
Contact life
Switching operations Ops.
220 V 50 Hz AC-1
360 contact sequences/h
Derating factor F
at inductive load
0.5
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
105
1.0
cos v
[A]
DC load (resistive)
U
[V]
400
300
400
300
200
200
100
80
60
100
80
60
40
30
40
30
20
20
10
0.1
0.2
0.5
10
10
0.1
0.2
0.5
[A]
Contact life
Ops.
1.0
0.9
10
8
6
0.8
0.7
0.6
Derating factor F
at inductive load
0.5
0.1
10
[A]
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
cos v
10 5
Contact life
Switching operations Ops.
220 V 50 Hz AC-1
360 contact sequences/h
1
8
[A]
04/037
Moeller HPL0211-2001/2002
Weight
Mounting
Terminal capacity
Solid
Min./Max.
Flexible with ferrule
Min./Max.
Width of standard screwdriver
Tightening torque
Ambient climatic conditions
Operational ambient temperature: horizontal / vertical installation
Condensation
LCD display (clearly legible)
Storage/transport temperature
Relative humidity, non-condensing (IEC 60 068-2-30)
Air pressure (operation)
Corrosion resistance
IEC 60 068-2-42
4 days SO2
IEC 60 068-2-43
4 days H2S
Ambient conditions, mechanical
Pollution degree
Degree of protection (EN 50 178, IEC 60 529, VBG 4)
Vibration resistance to IEC 60 068-2-6
Constant amplitude 0.15 mm
Constant acceleration, 2 g
Mechanical shock resistance (half-sinusoidal shock 15 g/11 ms)
to IEC 60 068-2-32
Drop to IEC 60 068-2-31
drop height
Free fall, packaged (IEC 60 068-2-32)
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61 000-4-2, severity level 3, ESD)
Air discharge
Contact discharge
Electromagnetic fields (IEC/EN 61 000-4-3, RFI)
Radio interference suppression
Burst pulses (IEC/EN 61 000-4-4, Level 3)
Supply cables
Signal lines
High-energy pulses (surge) EASY-AC (IEC/EN 61 000-4-5)
High-energy pulses (surge) EASY-DC (IEC/EN 61 000-4-5,
severity level 2)
Immunity to line-conducted interference to IEC EN 61 000-4-6
Dielectric strength
Clearance in air and creepage distances dimensioned to
Dielectric strength
Back-up/accuracy of real-time clock (only on EASY-...C)
Clock battery back-up
at 25 C
at 40 C
Accuracy of the real-time clock
Repetition accuracy of timing relays
Accuracy of timing relays (of values)
Resolution
Range s
Range M:S
Range H:M
Retentive memory
Write cycles of the retentive memory
EASY6...-...
kg
35.5 90 53
71.5 90 53
107.5 90 53
(2 space units)
(4 space units)
(6 space units)
0.07
0.2
0.3
On EN 50 022 top-hat rail, 35 mm, or
screw fixing, using ZB4-101-GF1 fixing brackets (accessories)
mm
mm
mm
Nm
0.2/4
0.2/2.5
3.5 0.8
0.6
C
C
%
hPa
0/+55
40/+70
5 95
795 1080
cm/m
cm/m
10
1
10
1
10
1
2
IP20
2
IP20
2
IP20
Hz
Hz
Impacts
10 57
57 150
18
10 57
57 150
18
10 57
57 150
18
mm
m
50
1
50
1
50
1
kV
kV
V/m
8
8
6
6
10
10
EN 55 011 Class B, EN 55 022 Class B
8
6
10
kV
kV
kV
2
2
2 (supply cable, balanced)
2
2
2
2
kV
10
10
10
mm
(AWG 22 12)
(AWG 22 12)
3.5 0.8
0.6
3.5 0.8
0.6
EN 50 178
h
h
s/day
Normally 64
Normally 24
Normally g 5
(~ g 0.5 h/year)
Normally 64
Normally 24
Normally g5
(g 0.5 h/year)
g1
g1
ms
s
min
10
1
1
10
1
1
f 100 000
f 100 000
Relays
Contactor Relays
EASY412-...
04/038
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Power supply
Rated operational voltage
Admissible range
Frequency, rated value, tolerance
Input current
at 115/120 V AC 60 Hz
at 230/240 V AC 50 Hz
Voltage dips (IEC/EN 61 131-2)
Heat dissipation
at 115/120 V AC
at 230/240 V AC
Power supply
Rated operational voltage
Admissible range
Residual ripple
Input current at 24 VDC
Voltage dips (IEC/EN 61 131-2)
Heat dissipation at 24 V DC
EASY412-AC-...
EASY61...-AC-R...
V AC
V AC
Hz
110/115/120/230/240 (+10/15 %)
90 264
50/60 (g 5 %)
100/110/115/120/230/240 (+10/15 %)
85 264
50/60 (g 5 %)
mA
mA
ms
Normally 40
Normally 20
20
Normally 70
Normally 35
20
VA
VA
Normally 5
Normally 5
Normally 10
Normally 10
V DC
V DC
%
mA
ms
W
EASY412-DC-...
EASY412-DA-RC
EASY6...-DC-...
24 (15/+20 %)
20.4 28.8
F5
Normally 80
10
Normally 2
12 (15/+30 %)
10.2 15.6
G5
Normally 140
10
Normally 2
24 (15/+20 %)
20.4 28.8
F5
Normally 140
10
Normally 5
EASY412-AC-...
EASY618/619-AC-R...
8
LCD display (if provided)
12
LCD display (if provided)
No
No
Yes
No
No
Yes
V AC
V AC
Hz
mA
0 40
79 264
50/60
6 x 0.5 (at 230 V AC 50 Hz)
6 x 0.25 (at 115 V AC 60 Hz)
0 40
79 264
50/60
10 (12) x 0.5 (at 230 V AC 50 Hz)
10 (12) x 0.25 (at 115 V AC 60 Hz)
mA
ms
ms
80/66 n
20/16 n
80/66 n
20/16 n
ms
ms
160/150
100/100
80/66 n
20/16 n
ms
ms
80/66 n
20/16 n
80/66 n
20/16 n
Normally 40
Normally 40
Normally 100
Normally 100
Moeller HPL0211-2001/2002
04/039
EASY412-DC-...
EASY412-DA-RC
EASY6...-DC...
No
No
Yes
12
< 4.0 (I1 I8)
> 8.0 (I1 I8)
mA
No
No
Yes
24
< 5.0 (I1 I8)
> 15.0 (I1 I6)
> 8.0 (I7 I8)
3.3 (at 24 V DC)
No
No
Yes
24
< 5.0 (I1 I12, R1 R12)
> 15.0 (I1 I6, I9 I12, R1 R12)
> 8.0 (I7 I8)
3.3 (at 24 V DC)
mA
ms
20
20
20
Debounce Off
ms
ms
20
20
20
Debounce Off
ms
Digital inputs 24 V DC
Quantity, of which 2 inputs (I7, I8)
can be used as analog inputs
Status display
Potential isolation
From power supply
Between digital inputs
From the outputs
Rated operational voltage
at signal 0
at signal 1
Input current at signal 1
R1 to R12, I1 to I6
(EASY620/621 also I9 to I12)
Input current at signal 1
(I7, I8)
Delay time from 0 to 1
Debounce On
Analog inputs
Number
Potential isolation
From power supply
From the digital inputs
From the outputs
Input type
Signal range
Resolution, analog
Resolution, digital
V DC
V DC
V DC
V DC
V
EASY412-D...
EASY6...-DC-...
No
No
Yes
DC voltage
0 10
0.1
0.1
No
No
Yes
DC voltage
0 10
0.1
0.1
U[V]
9.9
5.0
5.0
9.9
Input impedance
Accuracy of actual value
kO
11.2
11.2
%
%
ms
Input current
Cable length (unscreened)
mA
m
g3
g 2 (I7, I8) g 0.12 V
Input delay On: 20
Debounce Off: every cycle
<1
30
g3
g 2 (I7, I8) g 0.12 V
Input delay ON: 20
Debounce OFF: every cycle
<1
30
Relays
Contactor Relays
04/040
Moeller HPL0211-2001/2002
Relays
Contactor Relays
EASY412-...-R...
Relay outputs
Number
in groups of
Parallel connection of outputs to increase performance
Protection for one output relay
Potential isolation from mains supply, inputs
Safe isolation
Basic insulation
Lifespan, mechanical operations
Relay contacts
Conventional thermal current (10 A UL)
Recommended for load: 12 V AC/DC
Protection against short circuit, cos v = 1,
characteristic B16 at 600 A
Protection against short circuit, cos v = 0.5 0.7,
characteristic B16 at 900 A
Rated impulse withstand voltage Uimp contact to coil
Rated insulation voltage Ui
Rated operational voltage Ue
Safe isolation to EN 50 178 between coil and contact
Safe isolation to EN 50 178 between two contacts
Making capacity
AC-15 250 V AC, 3 A (600 Ops/h)
DC-13 L/R F150 ms 24 V DC, 1 A (500 Ops/h)
Breaking capacity
AC-15 250 V AC, 3 A (600 Ops/h)
DC-13 L/R F150 ms 24 V DC, 1 A (500 Ops/h)
Filament lamp load
1000 W at 230/240 V AC
500 W at 115/120 V AC
Fluorescent tubes
10 x 58 W at 230/240 V AC
With upstream electrical device
Uncompensated
1 x 58 W at 230/240 V AC
Conventional, compensated
Operating frequency, relays
Mechanical operations
Mechanical switching frequency
Resistive load/ lamp load
Inductive load
UL/CSA
Uninterrupted current at 240 V AC/24 V DC
AC
Control Circuit Rating Codes (utilization category)
Max. rated operational voltage
Max. thermal uninterrupted current at B 300
Max. Make/Break at B 300
EASY618/619-...-R...
V AC
V AC
x 106
4
6
1
1
Not admissible
Not admissible
Miniature circuit-breaker B16 or 8 A fuse (slow)
Yes
Yes
300
300
600
600
10
10
A
mA
A
8
> 500
16
8
> 500
16
16
16
kV
V AC
V AC
V AC
V AC
6
250
250
300
300
6
250
250
300
300
Operations
Operations
300 000
200 000
300 000
200 000
Operations
Operations
300 000
200 000
300 000
200 000
Operations
Operations
25 000
25 000
25 000
25 000
Operations
Operations
25 000
25 000
25 000
25 000
Operations
25 000
25 000
x 106
Hz
Hz
Hz
10
10
2
0.5
10
10
2
0.5
10/8
10/8
V AC
A
VA
V DC
A
VA
DC
Control Circuit Rating Codes (utilization category)
Max. rated operational voltage
Max. thermal uninterrupted current at B 300
Max. Make/Break at R 300
Moeller HPL0211-2001/2002
04/041
Transistor outputs
Number
Rated operational voltage Ue
Admissible range
Residual ripple
Supply current
at 0 signal
at 1 signal
Protection against polarity reversal
Potential isolation from power supply, inputs
EASY6...-DC-T...
4
24
20.4 28.8
F5
8
24
20.4 28.8
F5
mA
mA
9/16
12/22
Yes
Yes
18/32
24/44
Yes
Yes
A
W
mA
0.5
5
< 1.0
0.5
5
< 1.0
V DC
V DC
2.5
2.5
U = Ue 1 V
U = Ue 1 V
Yes (detected via diagnostics input I16, I15; R15, R16)
0.7 F Ie F 2
0.7 F Ie F 2
8
16
16
32
Yes
Yes
40 000
40 000
V DC
V DC
%
Normally/max.
Normally/max.
max.
Rated current Ie at 1 signal, DC
Lamp load without Rv
Residual current at signal 0, per channel
Max. output voltage
at signal 0 with external load < 10 MO
at signal 1, Ie = 0.5 A
Short-circuit protection
Short-circuit tripping current for Ra F 10 mO
Max. total short-circuit current
Peak short-circuit current
Thermal cutout
Max. operating frequency at constant resistive load (depending on
circuit configuration and load), RL < 100 kO
Parallel connection of outputs with resistive load;
inductive load with external suppression circuit, combination
within a group
Quantity of outputs
max.
Total maximum current
Status display of the outputs
Approvals
Currently UL/CSA approved; others in preparation:
Notes
EASY412-DC-T...
A
A
A
Ops./h
Group 1: Q1 to Q4
Group 1: Q1 to Q4, S1 to S4
Group 2: Q5 to Q8, S5 to S8
4
2.0
LCD display (if provided)
4
2.0
LCD display (if provided)
EASY200-EASY
EASY412-DC-R
EASY412-DC-RC
EASY412-DC-TC
EASY412-DC-TCX
EASY412-AC-R
EASY412-AC-RC
EASY412-AC-RCX
EASY618-DC-RC
EASY618-AC-RC
EASY618-AC-RE
EASY619-DC-RC
EASY619-DC-RCX
EASY619-AC-RC
EASY619-AC-RCX
EASY620-DC-TC
EASY620-DC-TE
EASY621-DC-TC
EASY621-DC-TCX
EASY412-DC-RC
EASY412-DC-TC
EASY618-DC-RC
EASY620-DC-TC
Relays
Contactor Relays
04/042
Moeller HPL0211-2001/2002
Relays
Contactor Relays
mm
kg
EASY204-DP
25/+55
25/+55
40/+70
40/+70
5 95
5 95
hPa
795 1080
795 1080
cm3 /m3
cm3 /m3
10
1
10
1
IP20
IP20
Hz
Hz
10 57
57 150
10 57
57 150
Impacts
18
18
mm
50
50
kV
kV
8
6
8
6
V/m
10
10
kV
2 (AS-Interface cables)
kV
10
10
EN 50 178
EN 50 178
0.2/4
(AWG 22 12)
0.2/2.5 (AWG 22 12)
3.5 0.8
0.6
0.2/4
(AWG 22 12)
0.2/4
(AWG 22 12)
3.5 0.8
0.6
mm
mm
mm
Nm
Moeller HPL0211-2001/2002
04/043
Power supply
Rated operational voltage
Total power consumption
(from yellow AS-Interface cable)
Admissible range
Residual ripple
Input current at 24 VDC
Voltage dips (IEC/EN 61 131-2)
Heat dissipation at 24 V DC
Protection against polarity reversal
AS-Interface protected against polarity reversal
AS-Interface profile cable
Slave addresses
Addressing unit interface
Power supply
LED displays
Logic links
EASY600 contact/coil t AS-Interface
EASY205-ASI
EASY204-DP
V DC
mA
26.5 31.6
30
24 (15/+20 %)
V DC
%
mA
ms
W
20.4 28.8
<5
Normally 200
10
Normally 4.8
Yes
7F (hex)
0. 1 31
3.5 mm socket
Yes
Power: green
Com-Error: red
S1 l Input 0
S2 l Input 1
S3 l Input 2
S4 l Input 3
R1 m Output 0
R2 m Output 1
R3 m Output 2
R4 m Output 3
R5 m PARAMETEROUTPUT 0
R6 m PARAMETEROUTPUT 1
R7 m PARAMETEROUTPUT 2
R8 m PARAMETEROUTPUT 3
PROFIBUS-DP
Connection device
Potential isolation
Function
Interface
Bus protocol
Baud rates
Bus termination resistors
Bus addresses
Services
Cyclical
Acyclical
Relays
Contactor Relays
04/044
Moeller HPL0211-2001/2002
Relays
Contactor Relays
EASY400-POW
General technical data
Standards
Dimensions
Weight
Mounting position
Mounting
Ambient climatic conditions
Operational ambient temperature: horizontal/vertical installation
Cold to IEC 60 068-2-1
Heat to IEC 60 068-2-2
Condensation
Storage/transport temperature
Relative humidity
IEC 60 068-2-30, non-condensing
Air pressure (operation)
Corrosion resistance
IEC 60 068-2-42
4 days SO2
IEC 60 068-2-43
4 days H 2S
Max. altitude above sea level; above this, note derating
Ambient conditions, mechanical
Pollution degree
Degree of protection
EN 50 178, IEC 60 529, VBG 4
Vibration resistance to IEC 60 068-2-6
Constant amplitude 0.15 mm
Constant acceleration, 2 g
Mechanical shock resistance (half-sinusoidal shock 15 g/11 ms)
to IEC 60 068-2-27
Drop
to IEC 60 068-2-31
drop height
Free fall, packaged
to IEC 60 068-2-32
Electromagnetic compatibility (EMC)
Radio interference suppression
EN 55011, EN 55022, EN 50 081-2
Electrostatic discharge (IEC/EN 61 000-4-2, severity level 3, ESD)
Air discharge
Contact discharge
Electromagnetic fields (RFI)
to IEC/EN 61 000-4-3
field strength
Burst pulses
to IEC/EN 61 000-4-4, severity level 3
High-energy pulses (surge)
to IEC/EN 61 000-4-5, supply cable balanced
High-energy pulses (surge)
to IEC/EN 61 000-4-5, severity level 2,
output cable balanced
Immunity to line-conducted interference
to IEC/EN 61 000-4-6
Surge voltage
to IEC/EN 60 947
kg
25/+55
%
hPa
5 95
795 1080
cm3 /m3
cm3 /m3
m
10
1
2000
2
IP20
Hz
Hz
10 57
57 150
Impacts
18
mm
50
8
6
V/m
10
kV
kV
kV
0.5
10
kV
4.9
Moeller HPL0211-2001/2002
04/045
to EN 50 178
to EN 50 178
Class II to IEC 60 536
Yes, SELV to VDE 0100 Part 410, IEC 60 364-4-41, HD 384.4.41 S2
mm
mm
mm
Nm
0.2/4
(AWG 22 12)
0.2/2.5 (AWG 22 12)
3.5 0.8
0.6
V AC
V AC
Hz
Approx. A
A
ms
A
100/120/230/240 (15/+10 %)
85 264
47 63
0.3/0.15
<5
>10/>20
2/1 slow
FAZ-C1 or FAZ-B6
%
W
W
F 87
Normally 35
Normally 5
0.3/0.15
V DC
%
mV
%
%
24
g2
< 240
g1
g2
A
A
V
0 1.25
> 1.25
< 18
Yes, by current limitation
Yes, hiccup mode, approx. 10 Hz
W
W
W
10
5
30
V DC
24
Relays
Contactor Relays
EASY400-POW
04/046
Moeller HPL0211-2001/2002
Relays
Contactor Relays
DILER
...DILE
General technical data
Standards
Lifespan, mechanical
AC operated
Operations
DC operated
Operations
Maximum operating frequency, mechanical
Climatic proofing
Ambient temperature
Open
Min./Max.
Enclosed
Min./Max.
Mounting position
Mechanical shock resistance
Half-sinusoidal shock, 10 ms
Basic unit
Make/break contact
Basic unit with auxiliary contact module Make/break contact
Half-sinusoidal shock, 20 ms
Basic unit
Make/break contact
Basic unit with auxiliary contact module Make/break contact
Degree of protection
Protection against direct contact from the front when actuated
by a perpendicular test finger (IEC 536)
Dimensions
Weight
AC operated
DC operated
Terminal capacity
Solid
Flexible with ferrule to DIN 46 228
Solid or stranded
Min.
Max.
Terminal screw
Pozidriv screwdriver
Size
Standard screwdriver
Tightening torque
Max.
DILR
...DIL
106
10
106
Ops./h
20
20
9000
7000
Damp heat, constant, to IEC 60 068-2-3
Damp heat, cyclical, to IEC 60 068-2-30
25/+50
25/+50
25/+40
As required, except vertical
with A1/A2 at bottom
25/+40
As required,
except suspended
g
g
10/8
10/8
g
g
10/6
10/6
IP20
IP20 (DILR) IP00 (...DIL)
Finger and back-of-hand proof
20
a Page 04/065
a Page 04/066
kg
kg
0.17
0.2
a Page 15/022
a Page 15/022
mm2
mm2
mm2
mm2
1 (0.75 2.5)
2 (0.75 2.5)
1 (0.75 1.5)
2 (0.75 1.5)
1 (0.75 4)
2 (0.75 4)
1 (0.75 2.5)
2 (0.75 2.5)
AWG
AWG
18
14
M3.5
18
10
M3.5
mm
mm
2
0.8 5.5
16
2
0.8 5.5
16
Nm
1.2
1.2
Moeller HPL0211-2001/2002
04/047
Contacts
Interlocked opposing contacts to ZH 1/457, including auxiliary contact
module
Rated impulse withstand voltage Uimp
Overvoltage category/pollution degree
Rated insulation voltage Ui
Rated operational voltage Ue
Safe isolation to IEC 536 between coil and auxiliary contacts, and
between the auxiliary contacts
Rated operational current Ie
AC-15
220/240 V
380/415 V
500 V
DC-132)
Above 110 V and at L/R > 15 ms:
it is essential that an arc-quenching device
(RC suppressor) be used in parallel with the contacts.
C: 1 F, R: 0.5 in series
L/R 15 ms: e.g. contactor coils, solenoid valves,
DC motors
Contacts in series:
1
24 V
2 (1)
60 V
3 (1)
110 V
3 (1)
220 V
L/R 50 ms: e.g. magnetic clutches, solenoid brakes
Contacts in series:
2
24 V
2
60 V
3 (1)
110 V
3 (1)
220 V
Control circuit reliability at Ue = 24 V
Umin = 17 V, Imin = 5.4 mA
Fault probability
Conventional thermal current Ith
Component lifespan at Ue 240 V
AC-15
DC-13
L/R 50 ms:
Operations
2 contacts in series
at Ie 0.5 A
Short-circuit rating without welding when supplied directly from mains
or transformer > 1000 VA
Maximum overcurrent protective 220/240 V
device
380/415 V
220/230 V
Maximum fuse3)
500 V
500 V
Current heat loss at Ith
Per contact
AC operated
DC operated
Notes
1) Auxiliary
DILER
...DILE
DILR
...DIL
Yes
Yes
V AC
V AC
V AC
6000
III/3
690
600
300
6000
III/3
690
500
440
A
A
A
6 (4)1)
3 (2)1)
1.5
6
4
1.5
A
A
A
A
2.5
2.5
1.5
0.5
10
10 (6)
6 (3)
5 (1)
A
A
A
A
6
6
3 (1.5)
2 (1)
HF
A
a Page 04/032
a Page 04/032
106
0.15
a Page 04/032
PKZM0
PKZM0
FAZ-C
gG/gL A
A fast
4
4
6
10
4
2.4
4
16
W
W
0.2
0.3
0.8
0.8
contact module
Making and breaking conditions to DC-13, time constant as stated
3) See transparent overlay Fuses for time/current characteristics (please enquire)
2)
Relays
Contactor Relays
04/048
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Magnet systems
Voltage tolerance
AC operated
Single-voltage coil 50 Hz and
dual-voltage coil 50 Hz, 60 Hz
Pick-up
Dual-frequency coil ... V, 50/60 Hz
Pick-up
DC operated1)
Pick-up
Without auxiliary contact module
Pick-up
Power consumption
AC operated
Single-voltage coil 50 Hz and
dual-voltage coil 50 Hz, 60 Hz
Pick-up
Sealing
Dual-frequency coil
... V, 50/60 Hz at 50 Hz
Pick-up
Sealing
... V, 50/60 Hz at 60 Hz
Pick-up
Sealing
DC operated
Pull-in sealing
Duty factor
Switching times at 100 % U (approximate values)
AC operated
Closing delay
Make contact
Opening delay
With auxiliary contact module
Max. closing delay
DC operated
Closing delay
Make contact
Opening delay
With auxiliary contact module
Max. closing delay
Notes
1)
DILER
...DILE
DILR
...DIL
Uc
0.8 1.1
0.8 1.1
Uc
0.85 1.1
0.85 1.1
Uc
0.85 1.3
0.85 1.1
Uc
0.7 1.3
VA/W
VA/W
25/22
4.6/1.3
67/52
8.5/2.5
VA/W
VA/W
30/26
5.4/1.6
VA/W
VA/W
29/24
3.9/1.1
W
% DF
2.6
100
9.5
100
ms
14 21
22
ms
8 18
14
ms
45
ms
26 35
38
ms
15 25
ms
70
04/049
Moeller HPL0211-2001/2002
Ambient temperature
Open
Min./Max.
Min./Max.
Enclosed
Min./Max.
Min./Max.
Mounting position
Mechanical shock resistance
(half-sinusoidal shock, 20 ms)
Make/break contact
Mechanical latching
Degree of protection
Protection against direct contact from the front when
actuated by a perpendicular test finger (IEC 536)
Dimensions
Weight
Terminal capacity
Solid
Flexible with ferrule to DIN 46 228
Solid or stranded
Min.
Max.
Terminal screw
Pozidriv screwdriver
Standard screwdriver
Tightening torque
Max.
Notes
1)
ETS4-VS3
106
106
10
30
Ops./h
Ops./h
3600 (100)1)
1500
3600 (100)1)
1500
Damp heat, constant, to IEC 60 068-2-3
Damp heat, cyclical, to IEC 60 068-2-30
9000
72000
C
C
25/+50
(10/+50)1)
25/+50
25/+50
25/+60
C
C
25/+40
(10/+40)1)
As required, except
suspended2)
25/+40
25/+40
25/+45
As required
As required
As required
10/6
IP00
Finger and back-of-hand
proof
20
IP00
Finger and
back-of-hand proof
10/
IP00
Finger and
back-of-hand proof
10/
IP20
Finger and
back-of-hand proof
kg
a Page 04/066
0.08
a Page 04/066
0.1
a Page 04/066
0.04 (VS1)
0.05 (VS2)
a Page 04/066
0.09
mm2
mm2
mm2
mm2
1 (0.5 2.5)
2 (0.5 2.5)
1 (0.5 1.5)
2 (0.5 0.75)
1 (0.5 2.5)
2 (0.5 2.5)
1 (0.5 1.5)
2 (0.5 0.75)
1 (0.75 4)
2 (0.75 4)
1 (0.75 2.5)
2 (0.75 2.5)
1 (0.75 2.5)
2 (0.75 1.5)3)
1 (0.75 2.5)
2 (0.75 1.5)3)
AWG
AWG
Size
mm
mm
18
14
M3
2
0.8 5.5
16
18
14
M3
2
0.8 5.5
16
18
12
M3.5
2
0.8 5.5
16
16
14
M3.5
2
0.8 5.5
16
Nm
1.2
1.2
1.2
1.2
g
g
TPEH11DIL, TPDH11DIL
DILR ... -G + TPD(H)11DIL: do not mount vertically
3) Use equal cross-sections only
2)
VS1DIL
VS2DIL
Relays
Contactor Relays
VDIL
04/050
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Contacts
Interlocked opposing contacts to ZH 1/457, including auxiliary contact
module
Rated impulse withstand voltage Uimp
Overvoltage category/pollution degree
Rated insulation voltage Ui
Rated operational voltage Ue
Rated operational current Ie
AC-15
220/240 V
380/415 V
DC-13 1)
Above 110 V and at L/R > 15 ms:
it is essential that an arc-quenching device
(RC suppressor) be used in parallel with the contacts.
C: 1 F, R: 0.5 in series
L/R 15 ms: e.g. contactor coils, solenoid valves, DC motors
Contacts in series:
1
24 V
1
60 V
1
110 V
1
220 V
L/R 50 ms: e.g. magnetic clutches, solenoid brakes
Contacts in series:
1
24 V
1
60 V
1
110 V
1
220 V
L/R 300 ms
1
24 V
1
60 V
1
110 V
1
220 V
Control circuit reliability at Ue = 24 V, Umin = 17 V, Imin = 5.4 mA
Fault probability
Conventional thermal current Ith
Component lifespan at Ie 0.1 A/1.2 A
AC-15
230 V
Operations
DC-13
230 V
Operations
Short-circuit rating without welding when supplied directly
from mains or transformer > 1000 VA
Maximum overcurrent protective device
220/240 V
380/415 V
Maximum fuse2)
500 V
Current heat loss at Ith
Per contact, max.
Notes
1)
2)
TPE(H)11DIL
TPD(H)11DIL
VDIL
VS1DIL
VS2DIL
ETS4-VS3
Yes
V AC
V AC
6000
III/3
690
500
8000
III/3
690
415
4000
III/2
440
415
6000
III/3
440
440
A
A
4
4
1.5
1
2
2
A
A
A
A
10
6
3
1
1
1
1
1
2.6
1.0
0.6
0.2
A
A
A
A
4
4
1
0.5
0.5
0.5
0.5
0.5
2.0
0.6
0.08
0.08
A
A
A
A
0.2
0.2
0.2
0.2
0.6
0.2
0.08
0.03
HF
A
106
8/
7/1
106
0.85/
PKZM0
PKZM0
2.5
1.6
A gG/gL
A fast
0.3
04/051
Moeller HPL0211-2001/2002
Magnet systems
Voltage tolerance
AC operated
Single-voltage coil 50 Hz and
dual-voltage coil 50 Hz, 60 Hz
Dual-frequency coil ... V, 50/60 Hz
DC operated1)
Power consumption
AC operated
Single-voltage coil 50 Hz and
dual-voltage coil 50 Hz, 60 Hz
DC operated
Notes
2)
ETS4-VS3
0.8 1.1
Unlatching
Pick-up
Unlatching
Uc
Uc
Uc
0.85 1.1
0.8 1.1
0.75 1.25
0.85 1.2
Pick-up
Sealing
Pull-in sealing
VA/W
VA/W
W
13/12
5/2
26
0.27
0.6
% DF
100
100 at AC
200 ms at DC
100
100
Closing delay
Opening delay
ms
ms
6
2.5
7
3
Latching
Unlatching
Latching
Unlatching
ms
ms
ms
ms
%
%/K
< 3 (5)2)
0.2
35
25
45
25
%
ms
15
20
Coil 50/60 Hz
1)
VS1DIL
VS2DIL
Uc
Repetition accuracy
Time deviation in relation to ambient
temperature based on 20 C
Long-time deviation
Recovery time (after 100% time delay)
Lifespan, mechanical
VDIL
Unlatching
Duty factor
Switching times at 100 % U (approximate values)
DC operated
TPE(H)11DIL
TPD(H)11DIL
At 50 Hz, approximately 30% less than shown under General technical data
Relays
Contactor Relays
04/052
Moeller HPL0211-2001/2002
Relays
Contactor Relays
DILET-A
General technical data
Standards
Lifespan, mechanical
AC operated
DC operated
Climatic proofing
ETR4-A
ETR4-W
Ambient temperature
Open
Min./Max.
Enclosed
Min./Max.
Mounting position
Mechanical shock resistance (half-sinusoidal Make contact
shock, 20 ms)
Degree of protection
Terminals
Dimensions
Weight
Terminal capacity
Contacts
Rated impulse withstand voltage Uimp
Overvoltage category/pollution degree
Rated insulation voltage Ui
Rated operational voltage Ue
Safe isolation to IEC 536 between coil and auxiliary contacts,
and between the auxiliary contacts
Making capacity
AC-14
cos
= 0.3
440 V
AC-15
cos
= 0.3
220 V
DC-11
L/R 40 ms
Breaking capacity
AC-14
cos
= 0.3
440 V
AC-15
cos
= 0.3
220 V
DC-11
L/R 40 ms
Rated operational current Ie
AC-14
440 V
AC-15
220 V
DC-11 1)
Above 110 V and at L/R > 15 ms:
it is essential that an arc-quenching device
(RC suppressor) be used in parallel with the contacts.
C: 1 F, R: 0.5 in series
L/R 15 ms: e.g. contactor coils, solenoid valves,
DC motors
24 V
L/R 50 ms:
Conventional thermal current Ith
Short-circuit rating 2) without welding
Maximum fuse
Notes
DILET-W
1)
2)
106
106
30
30
30
30
Damp heat, constant, to IEC 60 068-2-3
Damp heat, cyclical, to IEC 60 068-2-30
30
30
30
30
C
C
20/+60
20/+45
As required
4
25/+60
20/+45
As required
4
25/+60
20/+45
As required
4
20/+60
20/+45
As required
4
IP20
IP20
a Page 04/066
a Page 04/066
0.09
0.09
a Page 04/046 (as DILER)
IP20
IP20
a Page 04/066
a Page 04/066
0.1
0.1
a Page 04/049 (as ETS4VS3)
V AC
V AC
V AC
6000
III/2
600
440
250
6000
III/2
600
440
250
6000
III/3
600
440
250
6000
III/3
600
440
250
A
A
Ie
48
50
1.1
48
50
1.1
48
50
1.1
48
50
1.1
A
A
Ie
3
3
1.1
3
3
1.1
3
3
1.1
3
3
1.1
A
A
3
3
3
3
3
3
3
3
A
A
A
1.5
1.2
6
1.5
1.2
6
1.5
1.2
6
1.5
1.2
6
A gG/gL
kg
V AC
04/053
Moeller HPL0211-2001/2002
DILET-A
DILET-W
ETR4-A
ETR4-W
a Page 04/017
a Page 04/017
a Page 04/019
a Page 04/019
a Page 04/017
a Page 04/017
a Page 04/019
a Page 04/019
VA/W
VA/W
2/
2/
0.5/
0.5/
2/
2/
0.5/
0.5/
W
W
% DF
Ops./h
1.8
1.8
100
4000
100
4000
1.8
1.8
100
4000
100
4000
Magnet systems
Voltage tolerance
AC operated 50/60 Hz
Pick-up
DC operated1) when supplied directly from
mains or transformer > 1000 VA
Pick-up
Power consumption
AC operated 50/60 Hz
Pick-up
Sealing
DC operated
Pick-up
Sealing
Duty factor
Maximum operating frequency
Minimum command time
AC/DC
Voltage variation
Variation due to temperature fluctuation based on
20 C
Repetition accuracy (deviation)
Recovery time (after 100% time delay)
ms
%U
50/30
0.01
0.025
50/
0.01
0.025
50/30
0.01
0.025
50/
0.01
0.025
%
ms
0.1
70
0.1
70
0.1
70
0.1
70
ms
4 (50)2)
4 (50)2)
Notes
1)
2)
Not DILET-W
ETR4-51
Relays
Contactor Relays
04/054
Moeller HPL0211-2001/2002
Relays
Contactor Relays
ESR3-NO-31
General technical data
Standards
Lifespan, mechanical
Maximum operating frequency
Climatic proofing
Ambient temperature
Storage temperature
Mounting position
Vibration resistance
Degree of protection
Enclosure
Terminals
Protection against direct contact from the
front when actuated by a perpendicular
test finger (IEC 536)
Dimensions
Weight
Terminal capacity
Flexible with ferrule
Operations
x106
Ops./h
Min./Max.
Min./Max.
C
C
g
ESR4-NO-31
ESR4-NO-21
IP40
IP20
a Page 04/067
0.36
a Page 04/067
0.2
a Page 04/067
0.2
1 x (0.5 1.5)
2 x (0.5 1.5)
1 x (0.75 2.5)
2 x (0.75 2.5)
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
Size
mm
0.6 x3.5
0.6 x3.5
Nm
0.6
0.6
V AC
4000
4000
4000
V AC
V AC/DC
III/3
III/2
300
230
III/3
III/2
300
230
III/3
III/2
300
230
A
A
A
A
6
6
3
18
6
6
3
12
6
6
3
12
Short-circuit protection
Fuse
gG/gL A
kg
mm
Solid
mm
Terminal screw
Pozidriv screwdriver
Standard screwdriver
Tightening torque
Main contacts
Rated impulse withstand voltage Uimp
Overvoltage category/pollution degree
outside
inside
Rated insulation voltage Ui
Rated operational voltage Ue
Rated operational current Ie
AC-15
DC-13
230 V
24 V (360 Ops./h)
24 V (3600 Ops./h)
Moeller HPL0211-2001/2002
04/055
ESR4-NV3(30)-30
ESR4-NT30-30
ESR4-NM-21
ESR4-NZ-21
ESR4-NE-42
ESR4-VE3-42
10
3600
10
3600
25/+55
25/+70
As required
25/+55
25/+70
As required
IP40
IP40
IP20
IP20
Finger and back-of-hand proof
IP40
IP20
IP40
IP20
IP40
IP20
a Page 04/067
0.2
a Page 04/067
0.2
a Page 04/067
0.2
a Page 04/067
0.2
a Page 04/067
0.2
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
1 x (0.25 2.5)
2 x (0.25 0.5)
1 x (0.14 2.5)
2 x (0.14 0.75)
0.6 x3.5
0.6 x3.5
0.6 x3.5
0.6 x3.5
0.6 x3.5
0.6
0.6
0.6
0.6
0.6
4000
4000
4000
4000
4000
III/3
III/2
300
230
III/3
III/2
300
230
III/3
III/2
300
230
III/3
III/2
300
230
III/3
III/2
300
230
6
6
3
12
6
6
3
12
6
6
3
12
6
6
3
12
6
6
3
12
Relays
Contactor Relays
04/056
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Magnet system
Actuating voltage Uc
Voltage tolerance
Power consumption
AC operated 50/60 Hz
DC operated
Control circuit
Rated output voltage
No-load voltage
Rated current
Short-circuit current
Protection
Response time
Recovery time
Inputs
Rated current
Response time tA1
(with reset monitoring)
Response time tA1
(without reset monitoring)
Reset time tR /tR1
Minimum contact closing time tM
Recovery time tW
Synchronous monitoring time tS
EMC
Emitted interference
Noise immunity
Pick-up
ESR3-NO-31
ESR4-NO-31
ESR4-NO-21
V AC
V DC
xUc
230
0.85 1.1
24
24
0.85 1.1
24
24
0.85 1.1
VA/W
W
3.2/2.5
2.4/1.4
1.3
3.5/2.1
1.5
V DC
V DC
mA
A
F24
F40
40
1
Short-circuit proof
transformer
F24
40
1.4
PTC resistor
F24
50
2.2
PTC resistor
2000
3000
2000
3000
Y2: 40
ms
Y13, Y14: 40
Y12, Y31: 15
80
ms
500
50
60
ms
ms
ms
ms
50/100
50
500
40
50
< 50
40/100
50
500
ms
ms
mA
Moeller HPL0211-2001/2002
04/057
ESR4-NV3(30)-30
ESR4-NT30-30
ESR4-NM-21
ESR4-NZ-21
ESR4-NE-42
ESR4-VE3-42
24
0.85 1.1
24
0.85 1.1
24
24
0.85 1.1
24
24
0.85 1.1
24
0.85 1.1
2.5
2.7
2.7/1.6
1.5
2.7/1.5
1.0
1.0
F24
50
2.2
PTC resistor
F24
50
0.1
Electronic protection
F24
60
1
PTC resistor
2000
3000
5
5
2000
3000
S12: 30
S31, S22: 20
80
Y2: 60
Y11, Y21: 60
200
60
40
25
25
25/adjustable
200
500
40/100
50
500
< 50
< 250
< 500
15
Relays
Contactor Relays
04/058
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Hysteresis
Max. measuring cycle
Temperature error
Error within supply voltage
Status indication
Supply voltage
Output relay energized
Relay output contacts
Rated operational voltage Ue
Rated operational current Ie AC-12
Rated operational current Ie AC-15
Rated operational current Ie DC-12
Rated operational current Ie DC-13
Maximum electrical lifespan (AC-12/230 V/5 A)
Short-circuit rating, max. fuse
Load limit curves
EMC
Electromagnetic compatibility
ESD
HF immunity to radiation
Burst
Surge
HF immunity to line-conducted interference
Operations
x 106
Min./Max.
Min./Max.
C
C
g
Terminals
Approx.
kg
EMR4-I15-2-A
EMR4-I15-2-B
30
25/+65
40/+85
As required
10
IP20
A Page 04/067
0.3
mm
mm
mm
Nm
2 x 2.5
2 x 2.5
2 x 2.5
2 x 2.5
5.5 x 0.8
5.5 x 0.8
0.5 0.8
0.5 0.8
Snap fitting on top-hat rail to EN 50 022
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
V AC
V AC
4000
III/3
400
4000
III/3
400
4000
III/3
400
V AC/DC
V AC
x Uc
VA
Hz
% DF
24 240
0.85 1.1
2
50 60
100
24 240
0.85 1.1
2
50 60
100
220 240
0.85 1.1
2
50 60
100
Adjustable
s
%
%/C
B1-C
B2-C
B3-C
A
A
A
%
ms
%/C
%
0.003 0.03
0.01 0.1
0.1 1
5 30
80
F 0.06
F 0.5
0.3 1.5
15
3 15
5 30
80
F 0.06
F 0.5
0.3 1.5
15
3 15
5 30
80
F 0.06
F 0.5
Green
Yellow
Green
Yellow
Green
Yellow
400
5
3
5
2.5
0.1
5
400
5
3
5
2.5
0.1
5
400
5
3
5
2.5
0.1
5
a Page 04/036
a Page 04/036
a Page 04/036
LED
LED
At 230 V
At 230 V
At 24 V
At 24 V
Operations
Fast/gL
V AC
A
A
A
A
x 106
A
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
Moeller HPL0211-2001/2002
04/059
Operations
x 106
Min./Max.
Min./Max.
C
C
g
Terminals
Approx.
kg
mm
mm
mm
Nm
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
Snap fitting on top-hat rail to EN 50 022
V AC
V AC
4000
III/3
400
L1, L2, L3
V AC
x Uc
VA
Hz
%
200 500
0.85 1.1
15
50 60
100
L1, L2, L3
V AC
Hz
ms
%/C
%
200 500
50 60
500
F 0.06
F 0.5
LED
At 230 V
At 230 V
At 24 V
At 24 V
Operations
Fast/gL
Yellow
V AC
A
A
A
A
x 106
A
500
4
3
4
2
0.3
10
a Page 04/036
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
Relays
Contactor Relays
EMR4-F500-2
04/060
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Operations
x 106
Min./Max.
Min./Max.
C
C
g
Terminals
Approx.
kg
EMR4-W500-2-D
EMR4-W580-2-D
30
25/+65
40/+85
As required
10
IP20
a Page 04/067
0.3
mm
mm
mm
Nm
2 x 2.5
2 x 2.5
2 x 2.5
2 x 2.5
5.5 x 0.8
5.5 x 0.8
0.5 0.8
0.5 0.8
Snap fitting on top-hat rail to EN 50 022
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
V AC
V AC
4000
III/3
400
4000
III/3
400
4000
III/3
400
V AC
x Uc
VA
Hz
%
160 300
0.85 1.1
3
50 60
100
300 500
0.85 1.1
3
50 60
100
300 500
0.85 1.1
3
50 60
100
Adjustable
Adjustable
s
s
%
%/C
0.1 10
0.1 10
F 0.5
F 0.06
0.1 10
0.1 10
F 0.5
F 0.06
0.1 10
0.1 10
F 0.5
F 0.06
Umin/Umax
V AC
%
ms
%/C
%
5
80
F 0.06
F 0.5
5
80
F 0.06
F 0.5
5
80
F 0.06
F 0.5
Green
Yellow
Red
Red
Red
Green
Yellow
Red
Red
Red
Green
Yellow
Red
Red
Red
500
5
3
5
2.5
0.1
5
a Page 04/036
500
5
3
5
2.5
0.1
5
a Page 04/036
500
5
3
5
2.5
0.1
5
a Page 04/036
LED
LED
LED
LED
LED
At 230 V
At 230 V
At 24 V
At 24 V
Operations
Fast/gL
V AC
A
A
A
A
x 106
A
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
Moeller HPL0211-2001/2002
04/061
Operations
x 106
Min./Max.
Min./Max.
C
C
g
Terminals
Approx.
50 Hz
L1, L2, L3
kg
mm
mm
mm
Nm
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
Snap fitting on top-hat rail to EN 50 022
V AC
V AC
4000
III/3
400
V AC
x Uc
VA
Hz
%
380 415
0.8 1.2
15
50
100
ms
%
%/C
500
F 0.5
F 0.06
V AC
Hz
%
%
%/C
%
380 415
50
5 15
20
F 0.06
F 0.5
LED
At 230 V
At 230 V
At 24 V
At 24 V
Operations
Fast/gL
Yellow
V AC
A
A
A
A
x 106
A
500
4
3
4
2
0.3
10
a Page 04/036
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
Relays
Contactor Relays
EMR4-A400-1
04/062
Moeller HPL0211-2001/2002
Relays
Contactor Relays
Operations
x 106
Min./Max.
Min./Max.
C
C
g
Terminals
Approx.
kg
EMR4-N500-2-B
EMR4-N500-2-A
30
25/+65
40/+85
As required
10
IP20
a Page 04/067
0.3
mm
mm
mm
Nm
2 x 2.5
2 x 2.5
2 x 2.5
2 x 2.5
5.5 x 0.8
5.5 x 0.8
0.5 0.8
0.5 0.8
Snap fitting on top-hat rail to EN 50 022
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
V AC
V AC
4000
III/3
400
4000
III/3
400
4000
III/3
400
V AC
V AC/DC
x Uc
VA/W
Hz
%
220 240
0.85 1.1
2.5
50 60
100
220 240
0.85 1.1
3
50 60
100
24 240
0.85 1.1
2
50 60 DC
100
0.1 10
0.1 10
B1
B2
B3
Maximum level
Minimum level
5 100
30
1.5 2.3
1
10
100
250
Maximum level
Minimum level
0.25 500
20
Maximum level
Minimum level
0.25 500
20
Green
Yellow
Green
Yellow
Green
Yellow
250
4
3
4
2
0.3
10
a Page 04/036
400
5
3
5
2.5
0.1
5
a Page 04/036
400
5
3
5
2.5
0.1
5
a Page 04/036
Adjustable
approx.
kO
V AC
kO
mA
nF
m
ms
LED
LED
At 230 V
At 230 V
At 24 V
At 24 V
Operations
Fast/gL
V AC
A
A
A
A
x 106
A
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
Moeller HPL0211-2001/2002
04/063
Operations
x 106
Min./Max.
Min./Max.
C
C
g
Terminals
Approx.
AC
At Rinsulation
x response value
Measuring circuits
Input
Response range
Minimum internal resistance of alternating current
Minimum internal resistance of direct current
Minimum internal resistance
Test resistance
Maximum insulation voltage
Maximum voltage being monitored/test voltage (EMR4-RAC-1-A = DC
voltage being monitored/test voltage)
Cable length for cancellation- and test button, maximum
Status indication
Supply voltage
LED
Faults
LED
Fault at L+
LED
Fault at L
LED
Relay output contacts
Rated operational voltage Ue
Rated operational current Ie AC-12
At 230 V
Rated operational current Ie AC-15
At 230 V
Rated operational current Ie DC-12
At 24 V
Rated operational current Ie DC-13
At 24 V
Maximum lifespan, electrical (AC-12/230 V/5 A)
Operations
Short-circuit rating, max. fuse
Fast/gL
Load limit curves
EMC
Electromagnetic compatibility
ESD
HF immunity to radiation
Burst
Surge
HF immunity to line-conducted interference
kg
EMR4-RAC-1-A
mm
mm
mm
Nm
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
Snap fitting on top-hat rail to EN 50 022
2 x 2.5
2 x 2.5
5.5 x 0.8
0.5 0.8
V AC
V AC
4000
III/3
400
4000
III/3
400
V AC/DC
x Uc
VA
Hz
%
24 240
0.85 1.1
5.5
50 60
100
24 240
0.85 1.1
4.5
50 60
100
s
s
<1
< 0.9
<1
< 0.9
kO
kO
kO
kO
kO
V
V DC
L+, L, PE
10 110
57
300 DC
24 240
L, PE
1 11, 10 110
100
100
0.82
415 AC
F 30
10
10
Green
Yellow
Red
Red
Green
Red
Red
Red
400
5
3
5
2.5
0.1
5
a Page 04/036
320
5
3
3
2.5
0.1
5
a Page 04/036
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
IEC/EN 61 000-6-2
IEC/EN 61 000-4-2 Level 3
IEC/EN 61 000-4-3 Level 3
IEC/EN 61 000-4-4 Level 3
IEC/EN 61 000-4-5 Level 4
IEC/EN 61 000-4-6 Level 3
V AC
A
A
A
A
x 106
A
Relays
Contactor Relays
EMR4-RDC-1-A
04/064
Moeller HPL0211-2001/2002
EASY2...
EASY4...
10.75
Relays
Contactor Relays
7.5
50
45
110
90
102
M4
4.5
M4
7.5
47.5
35.75
56.5
35.5
71.5
58
EASY6...
75
16.25
45
110
90
M4
102
16.25
4.5
107.5
47.5
56.5
58
04/065
Moeller HPL0211-2001/2002
DILER-... + ...DILE
DILER-...-G + ...DILE
5,5
2DILER-... + MVDILE
2DILER-...-G + MVDILE
58
45
58
43
45
90
65,3
58
62,5
DILER-... + RCDILE
DILER-...-G + VGDILE
63
45
52
94
90
75
~125
DILER-... + TDDILE24
45
4,7
67
a
b
c
RCBDIL
33
15
30
FDBDIL
33
15
30
VGBDIL
33
15
30
VS1DIL
45
26
55
VS2DIL
45
26
55
Relays
Contactor Relays
DILER-... + HDILE
DILER-...-G + HDILE
35
83
45
52
45
50
58
58
M4
04/066
Moeller HPL0211-2001/2002
DILR Contactor Relays, DILET, ETR4 Electronic Timing- and Special-Purpose Relays
Dimensions
Contactor relays
Relays
Contactor Relays
DILR22(-G)
DILR22D(-G)
DILR31(-G)
DILR40(-G)
DILR22(-G) + ...DIL
DILR31(-G) + ...DIL
DILR40(-G) + ...DIL
DILR44D(-G)
DILR53D(-G)
DILR22(-G) + TPE(TPD)11DIL
DILR31(-G) + TPE(TPD)11DIL
DILR40(-G) + TPE(TPD)11DIL
c2
c1
4.7
35
77
60
38.5
45
2 M4
DILR22
DILR31
DILR40
DILR22D
(-G)
(-G)
(-G)
(-G)
DILR22+...DIL
DILR31+...DIL
DILR40+...DIL
DILR44D
DILR53D
c (with HDIL)
76.5
(101.5)
c (without
74
(99)
HDIL)
107
c1
(-G)
(-G)
(-G)
(-G)
(-G)
(132)
DILR22+TPE11DIL
DILR22+TPD11DIL
DILR31+TPE11DIL
DILR31+TPD11DIL
DILR40+TPE11DIL
DILR40+TPD11DIL
136
16
(-G)
(-G)
(-G)
(-G)
(-G)
(-G)
161
DILR22+VDIL
DILR31+VDIL
DILR40+VDIL
(-G)
(-G)
(-G)
137
162
52
45
M4
45
58
58
5,5
45
Remote potentiometer
ETR4-11...
ETR4-51...
ETR4-69...
ETR4-70...
RR-10
50
DILET...
65,3
35
2...8
103
98
22,5
12,5
78
82,5
3,2
22,5
29
17
29
48
04/067
Moeller HPL0211-2001/2002
3.8
Relays
Contactor Relays
75
52.5
107
45
120.5
ESR4-NO-31
ESR4-NO-21
ESR4-NM-21
ESR4-NZ-21
ESR4-NV3(30)-30
ESR4-NT30-30
ESR4-NE-42
ESR4-VE3-42
99
111.5
22.5
114
102
b
78
EMR4-I1-2-A
EMR4-I15-2-A
EMR4-I15-2-B
EMR4-F500-2
EMR4-W500-2-C
EMR4-W500-2-D
EMR4-W580-2-C
EMR4-A400-1
EMR4-N100-1-B
EMR4-N500-2-B
EMR4-N500-1-A
EMR4-RDC-1-A
EMR4-RAC-1-A
22.5
45
5.5
1
100
68.5
68.5
Sealable shroud
EMR4-PH...
22.5
45
b
K
K
K
K
K
K
K
K
K
K
K
K
K