Sei sulla pagina 1di 25

DAWBEE DVB-S2 Upgrade

Training
Georgios Potiriadis
Dissemination Operations Engineer

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 1

Purpose

The purpose of this presentation is to provide


information to the users of DAWBEE project to
enable the upgrade of the EUMETCast system to
DVB-S2 using the Ayecka SR1 DVB-S2 Receiver.

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 2

Outline

DVB-S PCI Card removal


Uninstallation of DVB-S PCI Card Drivers/Software
Satellite Dish Re-Alignment
DAWBEE Upgrade Configuration
Nominal
Degraded
SR1 (preconfigured) Installation
Connections LEDs
Reception Host Network Configuration
Connection & Reception test
Ayecka Web Interface
Installation
Run & Read from device
Tellicast Configuration
Tellicast Run
EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 3

DVB-S PCI Card Removal


Release the back panel which secures the plug-in cards
(two small catches on inside of box)

Please return the PCI card to EUMETSAT

Remove the card carefully from the PCI slot


EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 4

Uninstallation of DVB-S PCI Card Drivers/Software


From Tellicat Host Pc go to :

Double Click to uninstall the following two programs :

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 5

Satellite Dish Re-Alignment

The Basic Service can be received with the currently installed


antennas.
But the antenna needs to be re-pointed to Eutelsat E10A and
the reception optimized to achieve the best link margin.
The user should check the existing LNB and decide if there is
a need for it to be replaced.
The user should also check the existing wiring and F
connectors condition.
For more details see document :
http://www.eumetsat.int/website/wcm/idc/idcplg?IdcService=GET_FILE&dDocName=PDF_EUMETCAST_DVBS2_SETUP_GUIDE&RevisionSelection
Method=LatestReleased&Rendition=Web

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 6

DAWBEE Upgrade Configuration - Nominal

EUMETCast LAN Interconnect to PC2


PC NIC 2
(EUMETCast Files)

Satellite Antenna
and LNB

PC NIC 1
DVB IP Data
100Mbit LAN
Reception
Host

RF Coax Cable
Ayecka SR1
DVB-S2
Receiver

UPS
Outputs

PC NIC 2
(EUMETCast Files)

User LAN (if required)

Uninterruptible
Power Supply

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Visulisation
Host

PC NIC 1
(EUMETCast Files output)

Slide: 7

DAWBEE Upgrade Configuration - Degraded

User LAN (if required)

Degraded Mode

PC NIC 2
(EUMETCast Files)

Satellite Antenna
and LNB

Where
visualisation
or
reception host
system
has failed

PC NIC 1
DVB IP Data
100Mbit LAN
Reception
Host
Visulisation
Host

RF Coax Cable
Ayecka SR1
DVB-S2
Receiver

UPS
Outputs

Uninterruptible
Power Supply

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

PC NIC 2
(EUMETCast Files)

Visulisation
Host

Slide: 8

Ayecka SR1 DVB-S2 Receiver Connections

Satellite Cable (F Connector)


Power Supply

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Network Cable

Slide: 9

Ayecka SR1 DVB-S2 Receiver - LEDs


POWER LED STATUS

INDICATION
Red - The LED will stay red until the SR1starts loading the Firmware, or in case of a
fault in Firmware loading.
Red/Green Blinking During Firmware programming process, (5-8 seconds)
N.B. If the Firmware programming fails, the led will turn red again.
Green - The led turns green constantly after two conditions are met:

The SR1 application software has been successfully launched

AND

The Firmware has been successfully programmed

Power LED

RF1 Input

Lock 1 LED

F type Female Connector


L-Band ( -35 to -75 dBm )
RED : Receiver #1 is not locked
Blinking RED :Receiver #1 is in lock
process
Green: Receiver #1 is locked

LOCK 1 LED
EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 10

Reception Host Network Configuration


EUMETCast LAN Interconnect to PC2
PC NIC 2
(EUMETCast Files)

2
Satellite Antenna
and LNB

PC NIC 1
DVB IP Data
100Mbit LAN
Reception
Host

RF Coax Cable
Ayecka SR1
DVB-S2
Receiver

1
2

PC NIC 2
(EUMETCast Files)

UPS
Outputs

User LAN (if required)

Uninterruptible
Power Supply

PC NIC 2 EUMETCast LAN


Interconnect to PC2
No Changes required

PC NIC 1 SR1
IP change needed

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 11

Visulisation
Host

PC NIC 1
(EUMETCast Files output)

Connection & Reception Test (1/3)


1. At Command Prompt give the command :
telnet 192.168.10.99
Note : 192.168.10.99 SR1s Management Port IP
2. When asked for password give telnet and then
you will see this Screen :

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 12

Connection & Reception Test (2/3)

1. Enter 2 for Status


2. Enter 1 for RX Channel 1 Status

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 13

Connection & Reception Test (3/3)

1. Check Tuner Status , Demodulator Status, Transport status Should be Locked


2. Check Demodulator Link Margin at DVB-S2 8PSK 3/5 Should be > 4 dB

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 14

Ayecka Web Interface Installation 1/4


Download the latest version of Ayecka Web Interface if not already installed. You can download
the latest version from Ayeckas Web Interface download page: http://www.ayecka.com/webinterface/
To run Ayecka Web Interface on your Windows machine, you need to run server software on your
computer. To download and install the recommended server software, follow the following
instructions step by step.
Download the last version of WAMP from here: www.wampserver.com/en/ eg :
Install the WAMP server (double click the downloaded file).
Run the WAMP server.
Enter to "localhost" on your browser.
If you can see a page with the details of the server, your installation was successful. If not,
please check again the instructions in this guide.
Exit the WAMP server by right clicking on WAMP icon (on the taskbar) and choosing "Exit".
EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 15

Ayecka Web Interface Installation 2/4


Install Ayecka Web Interface Files :
Unzip the downloaded file from Ayecka Site (Slide 14) and choose the directory of your OS (in
this case, Windows). The directory contains 3 sub-directories:
Mysql
Configuration
www
Copy the sub-directory Content from the source directory to the destination directory on your
machine according to the table:
Source

Destination

/www/

yourHardDrive/wamp/www
Replace the original

/Configuration/ yourHardDrive/wamp/bin/php/phpversion/
Replace the original
EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 16

Ayecka Web Interface Installation 3/4


Update of mysql data :
Run the WAMP server
Enter to "localhost/phpmyadmin" in your browser.
Login as "root". The mysql server installed without password by default.
Select "Import" in the top menu. Select "Create_DB.sql" file from Mysql directory and click
"Go". This action will create new data base for Ayecka system.
Click "Ayecka" from the left databases list.
Select "Import" in the top menu. Select "Insert_tables.sql" file from Mysql directory and click
"Go". This action will add all Ayecka data to the database.

If you can see a page like this,


your installation was successful.

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 17

Ayecka Web Interface Installation 4/4


Check if the SNMP is started :
Click on WAMP icon (on the taskbar).
Select PHP.
Select PHP Extension.
Find the "SNMP" extension and make sure his selected.

Check if php_snmp is selected.

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 18

Ayecka Web Interface Run & Read from Device 1/4

1. Open in your Web Browser http://localhost/ page

2. Select SR1- Advanced DVB-S2 Receiver with GigE interface

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 19

Ayecka Web Interface Run & Read from Device 2/4

1. Open in your Web Browser http://localhost/ page


2. Select SR1- Advanced DVB-S2 Receiver with GigE interface
3. Click on Go

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 20

Ayecka Web Interface Run & Read from Device 3/4

1. Write the SR1 Management IP Address


2. Select Read From Device

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 21

Ayecka Web Interface Run & Read from Device 4/4

SR1 Device Readings

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 22

application must be given the fixed IP from which the data can be taken:
In the configuration file recv.ini the interface_address must be set to the reception host local IP Address:
interface_address=192.168.0.<nnn>

Tellicast Configuration

Open the recv.ini file at C:\EUMETSAT\EUMETCast directory

Go to the [parameters]
Delete or comment out the line:
interface_address=192.168.238.238
Add the line:
interface_address=192.168.10.103
Note : 192.168.10.103 Reception host local IP Address from
which the data can be taken:
Save & Close recv.ini file
Run tellicast client as usual

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 23

Tellicast Run

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 24

Questions
Any Questions?
Then refer to
EUMETCast Basic Service DVB-S2
Migration Setup Guide
DAWBEE DVB-S2 Receiver Upgrade
Setup Guide Procedures
SR1 Manual

All needed documents can be found at :


ftp://ftp.eumetsat.int/pub/OPS/out/user/projects/DAWBEE/
Feel free to ask!

EUM/OPS/DOC/14/769794
Issue 1
Training Date 15th September 2014

Slide: 25