Sei sulla pagina 1di 2

OVERALL HRSG EFFIC

DATA
Gas LHV
GAS OIL LHV
GT MW
Fuel Gas Flow
fuel gas inlet temperature
fuel gas inlet pressure
Fuel Gas Oulet temperature
Fuel Gas outlet pressure
HP economizer Inlet temperature
HP economizer inlet pressure
HP economizer enthalpy
HP economizer inlet mass flow
HP superheater oulet temperature (after attemperation)
HP superheater enthalpy (after attemperation)
HP superheater outlet mass flow (after attemperation)
HP superheater outlet pressure
Efficiency of HRSG
NOTE: SPECIFIC HEAT OF NATURAL GAS = Cv=1.85 KJ/Kg

RSG EFFICIENCY
DATA
Author:

46500
KJ
42870
KJ
Author:
Author:
236
MWlive data. Unit is still228
MWbased on heat balance
under
Author:
comissioning,
diagram
2000500 kg/hour
assumed valuetuning in 2145500
progress.
895.3 degree Kelvin
895.3
barg
437.4 degree Kelvin
437.4
barg
393 degree Kelvin
390.3
82.37 barg
116.2
509.52 KJ/KG
502.17
453950 kg/hour
484650
771.95 degree Kelvin
820.1
3410.1 KJ/kg
3496.3
439920 kg/hour
472840
67.81 bar g
98.32
74.88%
%
77.57%