Sei sulla pagina 1di 6

1

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
27s
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

List of device numbers and acronyms

44
45
46
47
48
49
50
50G
50N
50BF
51
51G
51N
52
52a
52b
53
54
55
56
57
58
59
60
61
62
63
64
64R
64S
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79

80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
150
AFD
CLK
DDR
DFR
DME
ENV
HIZ
HMI
HST
LGC
MET
PDC
PMU
PQM
RIO
RTU
SER
TCM
LRSS
SOFT

List of device numbers and acronyms

Master Element
Time Delay Starting or Closing Relay
Checking or Interlocking Relay
Master Contactor
Stopping
Starting Circuit Breaker
Rate of Change Relay
Control Power Disconnecting Device
Reversing Device
Unit Sequence Switch
Multi-function Device
Overspeed Device
Synchronous-speed Device
Underspeed Device
Speed or Frequency, Matching Device
Data Communications Device
Shunting or Discharge Switch
Accelerating or Decelerating Device
Starting to Running Transition Contractor
Electrically Operated Valve
Distance Relay
Equalizer Circuit Breaker
Temperature Control Device
Volts Per Hertz Relay
Synchronizing or Synchronize-Check Device
Apparatus Thermal Device
Undervoltage Relay
DC under voltage Relay
Flame detector
Isolating Contactor or Switch
AnnunciatorRelay
Separate Excitation
Directional Power Relay or Reverse Power Relay
Position Switch
Master Sequence Device
Brush-Operating or Slip-Ring Short-Circuiting Device
Polarity or Polarizing Voltage Devices
Undercurrent or Underpower Relay
Bearing Protective Device
Mechanical Condition Monitor
Field (over/under excitation) Relay
Field Circuit Breaker
Running Circuit Breaker
Manual Transfer or Selector Device

Unit Sequence Starting Relay


DC over voltage Relay
Reverse-phase or Phase-Balance Current Relay
Phase-Sequence or Phase-Balance Voltage Relay
Incomplete Sequence Relay
Machine or Transformer, Thermal Relay
Instantaneous Overcurrent Relay
Instantaneous Earth Over Current Relay (Neutral CT Method)
Instantaneous Earth Over Current Relay (Residual Method)
Breaker failure
AC Inverse Time Overcurrent Relay
AC Inverse Time Earth Overcurrent Relay (Neutral CT Method)
AC Inverse Time Earth Overcurrent Relay (Residual Method)
ACCircuit Breaker
AC Circuit Breaker Position (Contact Open when Breaker Open)
AC Circuit Breaker Position (Contact Closed when Breaker Open)
Exciter or DC Generator Relay
Turning Gear Engaging Device
Power Factor Relay
Field Application Relay
Short-Circuiting or Grounding Device
Rectification Failure Relay
Overvoltage Relay
Voltage or Current Balance Relay
Density Switch or Sensor
Time-Delay Stopping or Opening Relay
Pressure Switch
Ground Detector Relay
Restricted earth fault
Stator earth fault
Governor
Notching or Jogging Device
AC Directional Overcurrent Relay
Blocking Relay
Permissive Control Device
Rheostat
Liquid Level Switch
DC Circuit Breaker
Load-Resistor Contactor
Alarm Relay
Position Changing Mechanism
DC Overcurrent Relay
Telemetering Device
Phase-Angle Measuring Relay or "Out-of-Step" Relay
AC Reclosing Relay (Auto Reclosing)

Flow Switch
Frequency Relay
DC Reclosing Relay
Automatic Selective Control or Transfer Relay
Operating Mechanism
Communications,Carrier or Pilot-Wire Relay
Lockout Relay/Master Trip
Differential Protective Relay
Auxiliary Motor or Motor Generator
Line Switch
Regulating Device
Voltage Directional Relay
Voltage and Power Directional Relay
Field Changing Contactor
Tripping or Trip-Free Relay( trip circuit supervisen Relay)
For specific applications where other numbers are not suitable
Busbar Trip Lockout relay
For specific applications where other numbers are not suitable
For specific applications where other numbers are not suitable
For specific applications where other numbers are not suitable
Earth Fault Indicator
Arc Flash Detector
Clock or Timing Source
Dynamic Disturbance Recorder
Digital Fault Recorder
Disturbance Monitor Equipment
Environmental Data
High Impedance Fault Detector
Human Machine Interface
Historian
Scheme Logic
Substation Metering
Phasor Data Concentrator
Phasor Measurement Unit
Power Quality Monitor
Remote Input/Output Device
Remote Terminal Unit/Data Concentrator
Sequence of Events Recorder
Trip Circuit Monitor
LOCAL/REMOTE SELECTOR SWITCH
Switch On To Fault

Potrebbero piacerti anche