Explain Active power, Apparent Power and Reactive Power. B) explain resonance in RLC Series Circuit. What is Q-factor? c) Find the (i) current flowing in the circuit. (ii) power factor of the circuit. (iv) voltage across the reactor.
Explain Active power, Apparent Power and Reactive Power. B) explain resonance in RLC Series Circuit. What is Q-factor? c) Find the (i) current flowing in the circuit. (ii) power factor of the circuit. (iv) voltage across the reactor.
Explain Active power, Apparent Power and Reactive Power. B) explain resonance in RLC Series Circuit. What is Q-factor? c) Find the (i) current flowing in the circuit. (ii) power factor of the circuit. (iv) voltage across the reactor.
FANDAMENTAL OF ELECTRICAL ENGINEERING TIME: 3HRS MAX MARKS: 70
Q.1 a) Explain Active Power, Apparent Power & Reactive Power.
b) Explain resonance in RLC Series Circuit. What is Q-factor? c) A reactor having negligible resistance and an inductance of 0.1 H is connected in series with a resistor of 15 . The circuit is connected across a 230 V, 50 Hz, single phase. Find the (i) Current flowing in the circuit (ii) Power factor of the circuit (iii) Voltage across the reactor (iv) Voltage across the reactor Q.2 a) Drive the expression for (a) VL and VPH (b) IL and IPH b) Derive the line and phase voltage relation for a Star connected system? c) Two coil A and B have resistances of 12 and 6 and inductances of 0.02 and 0.03 H respectively. These are connected in parallel and a voltage of 200 v , 50 Hz is applied to their common terminals. Find: (a)Current in each coil (b)Total current (c) Power factor Q.3 a) Explain the following (a) Form Factor (b) Peak Factor b) Explain RLC Series circuit. c) Three inductive coil of 15 and an inductance of 0.03 H are connected in star to 3-phase 400 V, 50 Hz, supply. Calculate (a) Phase current (b) Line current (c) Total power absorbed Q.4 a) Explain power triangle and power factor. b) Prove that the power consumed by purely inductive and capacitive and capacitive circuit is zero. c) Draw and explain phasor diagram of a single phase transformer on load. Q.5 a) Explain power triangle including Active, Reactive & Apparent power. b) Analyse a RL circuit and draw the waveforms? c) A 5 KVA, 400/200 V, 50 Hz, single phase transformer gave the following test results during no load and short circuit test No load : 400V, 1A.60 W (primary side) Short Circuit : 15 V, 12.5 A, 50 W ( primary side) Calculate (i) The no load parameters R0 and Xm (ii) equivalent resistance and reactance referred to primary (iii) Regulation at full load and 0.8 pf lagging (iv) Iron and copper losses at full load (v) Efficiency at full load and 0.8 pf lagging Q.6 a) Define the following (a) Magnetic field strength (b) Reluctance b) Write down analogy between electric circuit and magnetic circuit. c) A steel ring of 25cm mean diameter and of circular section 3cm in diameter has an air gap of 1.5 mm length . It is wound uniformly with 700 turns ofwire carrying a current of 2A. Calculate1. Mmf 2. flux density 3.magnetic flux 4. Reluctance 5. Relative permeability of steel ring. Q.7 a) Derive the EMF equation of transformer. b) Explain different losses in a transformer. c) Draw the complete construction of transformer with details?