CUSTOMER DRAWING LIST

TRANSFORMER DIVISION

PCN

ADA1720007
ADA1720008

DRG. No.

41CL0598 R0

CUSTOMER : M/s. SIEMENS LTD.


P.O No. :
RATING : 4500kVA 33/0.433 kV 3 PHASE TRANSFORMER

SR.
No.

DESCRIPTION

DRG. No.

REV.

STATUS

GA OF TRANSFORMER (ADA1720008)

31GA1320

R0

FIRST SUBMISSION

GA OF TRANSFORMER (ADA1720007)

31GA1319

R0

FIRST SUBMISSION

RATING & DIAGRAM PLATE (ADA1720007)

31RD1084

R0

FIRST SUBMISSION

RATING & DIAGRAM PLATE (ADA1720008)

31RD1085

R0

FIRST SUBMISSION

LV BUSDUCT

31CD1447

R0

FIRST SUBMISSION

HV CABLE BOX

31CD1446

R0

FIRST SUBMISSION

GA OF MARSHALLING BOX

31CD1448

R0

FIRST SUBMISSION

MARSHALLING BOX WIRING DIAGRAM

31CD1449

R0

FIRST SUBMISSION

FOUNDATION

31CD1445

R0

FIRST SUBMISSION

10 GTP

ADA1720007

R0

FIRST SUBMISSION

11 GTP

ADA1720008

R0

FIRST SUBMISSION

DNA

SP

Sign

1
Rev.no

KVRR

Revision Note

Date

sign

Date

11.04.14 11.04.14 11.04.14


FORM NO:FM/TF/PMG/34

Doc
DATE : 11.04.2014

SR.NO

DESCRIPTION

Name Of Manufacturer

Service

3
4
5

Reference Standard
Kva Rating ( Hv / Lv Winding )
Rated Voltage
A. H.V. Winding
B. L.V. Winding

6
7
8

ADA1720008

REV NO
GUARANTEED TECHNICAL PARTICULARS
UOM

OUTDOOR

Rated Frequency

KVA
VOLT
VOLT

33000
433

Hz

50
3

No Of Phases
Connections With Symbol

Delta
Star

B. L.V. Winding

Dyn11

Vector Group
Tappings On Hv

Off Circuit Tap Changer

A. Type

4 steps 5 position

B. Number Of Steps

+5%to-5% @ 2.5%

C. Tap Range

11
12
13
14

15

16

17

18

19

20

21

PARTICULARS
RAYCHEM RPG (P) LTD
IS 2026,2011
4500

A. H.V. Winding

9
10

COPPER

Winding Material
Insulation Class

Type Of Cooling

ONAN

Temp. Rise Over Reference Amb. Temp. Of 50 C


C
A. In Oil By Thermometer
C
B. In Winding By Resistance
Total Loss At Rated Voltage On Principal Tappings & Rated Frequency @75C
Component Losses
KW
A.No Load Loss
(Max)

5.00

B.Load Loss

KW
%

38.0

%
%

7.10
0.84

KV RMS
KV RMS

70
3

KV PEAK
KV PEAK

170
NA

%
%

99.05
99.22

C. At 1/2 Full Load

99.36

Regulation At Full Load & 75C


A. At Unity Power Factor
B. At 0.8 Power Factor Lagging

%
%

1.10
5.07

3.41

Impedance At Principal Tap

(Max)
(+/- IS tol)

A. Reactance
B. Resistance At 75C
Insulation Level
A.Separate Source Power Frequency Voltage Withstand
I. Hv Winding
Ii.Lv Winding
B.Full Wave Lighting Impulse Withstand Voltage
I. Hv Winding
Ii.Lv Winding
Efficiency At 75 C & Unity Power Factor
A. At Full Load
B. At 3/4 Full Load

B. At 0.9 Power Factor Lagging


Terminal Arrangements
A. Hv Side
B. Lv Side
Approx. Weight
A. Core & Winding
B. Tank & Fittings
C. Oil

55
55

7.15

BARE BUSHING
Bus duct flange
Kg
Kg
Kg

4700
3300
2000

Kg
10000
D.Total Mass
C.Oil
Ltrs.
2440
Note:
1. Efficiency and regulation values are calculated based on nominal values of NLL,LL & %Z.
2. Weights and dimensions are subject to +/- 10% tol

Page 1 of 1
pared by : PD

Approved by : SP

FORM NO.FM/TF/PMG/13

Doc
DATE : 11.04.2014

SR.NO

DESCRIPTION

Name Of Manufacturer

Service

3
4
5

Reference Standard
Kva Rating ( Hv / Lv Winding )
Rated Voltage
A. H.V. Winding
B. L.V. Winding

6
7
8

ADA1720007

REV NO
GUARANTEED TECHNICAL PARTICULARS
UOM

INDOOR

Rated Frequency

KVA
VOLT
VOLT

33000
433

Hz

50
3

No Of Phases
Connections With Symbol

Delta
Star

B. L.V. Winding

Dyn11

Vector Group
Tappings On Hv

Off Circuit Tap Changer

A. Type

4 steps 5 position

B. Number Of Steps

+5%to-5% @ 2.5%

C. Tap Range

11
12
13
14

15

16

17

18

19

20

21

PARTICULARS
RAYCHEM RPG (P) LTD
IS 2026,2011
4500

A. H.V. Winding

9
10

COPPER

Winding Material
Insulation Class

Type Of Cooling

ONAN

Temp. Rise Over Reference Amb. Temp. Of 50 C


C
A. In Oil By Thermometer
C
B. In Winding By Resistance
Total Loss At Rated Voltage On Principal Tappings & Rated Frequency @75C
Component Losses
KW
A.No Load Loss
(Max)

5.00

B.Load Loss

KW
%

38.0

%
%

7.10
0.84

KV RMS
KV RMS

70
3

KV PEAK
KV PEAK

170
NA

%
%

99.05
99.22

C. At 1/2 Full Load

99.36

Regulation At Full Load & 75C


A. At Unity Power Factor
B. At 0.8 Power Factor Lagging

%
%

1.10
5.07

3.41

Impedance At Principal Tap

(Max)
(+/- IS tol)

A. Reactance
B. Resistance At 75C
Insulation Level
A.Separate Source Power Frequency Voltage Withstand
I. Hv Winding
Ii.Lv Winding
B.Full Wave Lighting Impulse Withstand Voltage
I. Hv Winding
Ii.Lv Winding
Efficiency At 75 C & Unity Power Factor
A. At Full Load
B. At 3/4 Full Load

B. At 0.9 Power Factor Lagging


Terminal Arrangements
A. Hv Side
B. Lv Side
Approx. Weight
A. Core & Winding
B. Tank & Fittings
C. Oil

55
55

7.15

Cable box
Bus duct flange
Kg
Kg
Kg

4700
3300
2000

Kg
10000
D.Total Mass
C.Oil
Ltrs.
2440
Note:
1. Efficiency and regulation values are calculated based on nominal values of NLL,LL & %Z.
2. Weights and dimensions are subject to +/- 10% tol

Page 1 of 1
pared by : PD

Approved by : SP

FORM NO.FM/TF/PMG/13

Potrebbero piacerti anche