Sei sulla pagina 1di 41

SUMMARY OF

SBC CALCULATIONS

Construction of Retaining Wall in km 81/8, 83/8, 83/10, 85/4, 92/8 and 93/8 of KANF road in
E.G.Dt.

SAMPLE No. CHAINAGE DEPTH

LEVEL

W%

ANGLE
OF
BULK
DRY
COHESIO INTERNA
DENSIT DENSIT
N T/M2
L
Y T/M2 Y T/M2
FRICTION
(Degree)

SBC
T/M2

KM.81/8 (115m - 81/665 TO 81/800)


BH-1

81/680

3M

30.38

1.88

1.44

BH-2

81/720

3M

28.74

1.87

1.46

2.2

BH-3

81/750

3M

13.04

1.84

1.63

2.1

BH-4

81/790

3M

34.53

1.82

1.35

0.9

35.21

1.77

1.31

2.6

2M

25.42

1.93

1.54

2.5

2M

45.31

1.63

1.12

0.7

KM.83/8 (10.5M - 83/789.5 TO 83/800)


BH-1

83/795

2M

KM.83/10 (15M - 83/800 TO 83/815)


BH-1

83/815

KM.85/4
BH-1

KM.92/8 (60M - 92/612 TO 92/672)


BH-1

92/620

2M

30.6

1.74

1.33

1.1

BH-2

92/680

2M

25.51

1.88

1.49

1.6

10

10

BH-3

92/765

2M

22.94

1.97

1.6

KM.93/8 (25M - 93/727 TO 93/752)


BH-1

93/670

1.5M

24.93

1.94

1.55

3.4

10

BH-2

93/715

1.5M

24.39

1.91

1.53

2.1

BH-3

93/750

1.5M

27.77

1.87

1.46

3.7

Asst. Executive Engineer (R&B),


R&B Section, Malikipuram

Deputy Executive Engineer (R&B),


R&B Subdivision, Razole

Superintending Engineer (R&B),


R&B Circle, Kakinada

Executive Engineer (R&B),


R&B Division, Amalapuram

S.B.C.Calculations (as per I.S: 6403-1981)


Improvements to Lakkavaram - Sankaraguptam road from km 0/0 to 3/0 in E.G.Dt. (Reconstruction of HLB
across Sankaraguptam Major Drain in km 2/2 of Lakkavaram - Sankaraguptam Road)
DATA:

km 2/2

Bore Hole No

Sample No

Location

A1

Depth of U.D.Sample(d)
Bulk Density( b )

12.000

1.61

t/m3

Moisture Content w in %

59.17

Dry Density (d )

1.01

t/m3

Cohesion ( C )

1.40

t/m2

For Local Shear failure ( C' = 2/3 * C)

0.93

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

2.200

Width of Footing B

14.06

Depth of Water Table below GL

0.0

Factor of Safety

2.5

LENGTH of footing

:
54.4
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

Shape Factors for RECTANGULAR Footing:


Sc=
1.052
Depth Factors :

N'q =

1.000

Sq=

1.052

N = tan (PI/4 + /2) =


2

dc =
1.031
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.98

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F0.93*5.14*1.052*1.031*1 (1.61-1)*2.2*(1-1)*1.052*1*1+ 0.5*14.06*1.61*0*0.98*1*1*0.5 ]


{

5.185

0.000

0.000

1.342

5.185
2.5

1.342

3.416

or say

3.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.052

1.052

0.90

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)

Improvements to Lakkavaram - Sankaraguptam road from km 0/0 to 3/0 in E.G.Dt.


(Reconstruction of HLB across Sankaraguptam Major Drain in km 2/2 of Lakkavaram Sankaraguptam Road)
DATA:

km 2/2

Bore Hole No

A1

Sample No

Location

A1

Depth of U.D.Sample(d)
Bulk Density( b )

16.000

1.67

Moisture Content w in %

60.33

Dry Density (d )

1.04

t/m3

Cohesion ( C )

1.70

t/m2

For Local Shear failure ( C' = 2/3

1.13

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

m
t/m3
%

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

2.000

Width of Footing B

14.1

Depth of Water Table below GL

0.0

Factor of Safety

2.5

LENGTH of footing
:
54.4
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x B b N' S d i W'} + (b-1)d
SBC=
c
c
c c
q
q
q q
F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0N = tan 2 (PI/4 + /2)


i - Inclination factor
W' = Water Table Correction factor If Dw > Df + B then W' = 1 If Dw < Df then W' = 0.5
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c

N'q =

1.456

Shape Factors for RECTANGULAR Footing:


Sc=
Sq=
1.008

1.008

6.220

Depth Factors :

N = tan (PI/4 + /2) =


2

dc =
1.028
dq=dv=1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor

N' = 0.360
S=

0.98

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F 1.13*6.22*1.008*1.02 (1.67-1)*2*(1.456-1)*1.00 0.5*14.06*1.67*0.36*0.98*1*1*0.5 ]


{

7.283

0.616

2.071

3.34

9.970
2.5

3.34

7.328

or say

6.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403

Sc

Sq

1.052

1.052

0.90

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Continous strip footing


Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0N = tan 2 (PI/4 + /2)


i - Inclination factor
W' = Water Table Correction factor If Dw > Df + B then W' = 1 If Dw < Df then W' = 0.5
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.93/8-1

(93/670)

Bore Hole No

Sample No

Location

Depth of U.D.Sample(d)
Bulk Density( b )

1.500

1.94

t/m3

Moisture Content w in %

24.93

Dry Density (d )

1.55

t/m3

Cohesion ( C )

3.40

t/m2

For Local Shear failure ( C' = 2/3 * C)

2.27

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

1.33

degr

> 360 GSF

1
RW3

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

3.400

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
60.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.680

Shape Factors for RECTANGULAR Footing:


Sc=
1.008
Depth Factors :

N'q =

1.228

Sq=

1.008

N = tan (PI/4 + /2) =


2

dc =
1.303
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.180
S=

0.98

1.048

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F2.27*5.68*1.008*1.303*1 (1.94-1)*3.4*(1.228-1)*1.008* 0.5*2.3*1.94*0.18*0.98*1*1*0.5 ]


{

16.935

0.735

0.197

3.196

17.866
2.5

3.196

= 10.342

or say

10.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.008

1.008

0.98

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.92/8-3

(92/765)

Bore Hole No

Sample No

Location

Depth of U.D.Sample(d)
Bulk Density( b )

2.000

1.97

t/m3

Moisture Content w in %

22.94

Dry Density (d )

1.60

t/m3

Cohesion ( C )

1.00

t/m2

For Local Shear failure ( C' = 2/3 * C)

0.67

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

4.01

degr

> 360 GSF

1
RW3

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

3.400

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
60.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

6.862

Shape Factors for RECTANGULAR Footing:


Sc=
1.008
Depth Factors :

N'q =

1.750

Sq=

1.008

N = tan (PI/4 + /2) =


2

dc =
1.317
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.602
S=

0.98

1.150

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F0.67*6.862*1.008*1.317*1 (1.97-1)*3.4*(1.75-1)*1.008*1 0.5*2.3*1.97*0.602*0.98*1*1*0.5 ]


{

6.103

2.493

0.668

3.298

9.265
2.5

3.298

7.004

or say

7.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.008

1.008

0.98

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.92/8-2

(92/680)

Bore Hole No

Sample No

Location

Depth of U.D.Sample(d)
Bulk Density( b )

2.000

1.88

t/m3

Moisture Content w in %

25.51

Dry Density (d )

1.50

t/m3

Cohesion ( C )

1.60

t/m2

For Local Shear failure ( C' = 2/3 * C)

1.07

t/m3

Angle of Internal Friction ( )

10

degr

< 280 LSF

6.70

degr

> 360 GSF

1
RW3

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

3.400

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
60.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 100

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

8.350

Shape Factors for RECTANGULAR Footing:


Sc=
1.008
Depth Factors :

N'q =

2.470

Sq=

1.008

N = tan (PI/4 + /2) =


2

dc =
1.332
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 1.220
S=

0.98

1.264

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F1.07*8.35*1.008*1.332*1 (1.88-1)*3.4*(2.47-1)*1.008*1 0.5*2.3*1.88*1.22*0.98*1*1*0.5 ]


{

11.996

4.433

1.292

2.992

17.722
2.5

2.992

= 10.081

or say

10.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.008

1.008

0.98

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 100

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.92/8-1

(92/620)

Bore Hole No

Sample No

Location

Depth of U.D.Sample(d)
Bulk Density( b )

2.000

1.74

t/m3

Moisture Content w in %

30.60

Dry Density (d )

1.33

t/m3

Cohesion ( C )

1.10

t/m2

For Local Shear failure ( C' = 2/3 * C)

0.73

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

2.67

degr

> 360 GSF

1
RW3

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

3.900

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
60.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

6.220

Shape Factors for RECTANGULAR Footing:


Sc=
1.008
Depth Factors :

N'q =

1.456

Sq=

1.008

N = tan (PI/4 + /2) =


2

dc =
1.355
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.360
S=

0.98

1.098

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F0.73*6.22*1.008*1.355*1 (1.74-1)*3.9*(1.456-1)*1.008* 0.5*2.3*1.74*0.36*0.98*1*1*0.5 ]


{

6.202

1.327

0.353

2.886

7.881
2.5

2.886

6.039

or say

6.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.008

1.008

0.98

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.85/4-1

Bore Hole No

Sample No

Location

Depth of U.D.Sample(d)
Bulk Density( b )

2.000

1.63

t/m3

Moisture Content w in %

45.31

Dry Density (d )

1.12

t/m3

Cohesion ( C )

0.70

t/m2

For Local Shear failure ( C' = 2/3 * C)

0.47

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

1
RW2

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

1.500

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
115.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N'q =

1.000

Sq=

1.004

N = tan (PI/4 + /2) =


2

dc =
1.130
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F0.47*5.14*1.004*1.13*1 + (1.63-1)*1.5*(1-1)*1.004*1*1+ 0.5*2.3*1.63*0*0.99*1*1*0.5 ]


{

2.741

0.000

0.000

0.945

2.741
2.5

0.945

2.041

or say

2.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.004

1.004

0.99

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.83/10

(83/815)

Bore Hole No

Sample No

Location

Depth of U.D.Sample(d)
Bulk Density( b )

2.000

1.93

t/m3

Moisture Content w in %

25.42

Dry Density (d )

1.54

t/m3

Cohesion ( C )

2.50

t/m2

For Local Shear failure ( C' = 2/3 * C)

1.67

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

1
RW2

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

2.500

Width of Footing B

1.8

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
15.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x
B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N'q =

1.000

Sq=

1.004

N = tan (PI/4 + /2) =


2

dc =
1.278
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F1.67*5.14*1.004*1.278*1 (1.93-1)*2.5*(1-1)*1.004*1*1+ 0.5*1.8*1.93*0*0.99*1*1*0.5 ]


{

11.014

0.000

0.000

2.325

11.014
2.5

2.325

6.731

or say

6.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.024

1.024

0.95

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.83/8

(83/795)

Bore Hole No

Sample No

Location

RW2

Depth of U.D.Sample(d)
Bulk Density( b )

2.000

1.77

t/m3

Moisture Content w in %

35.21

Dry Density (d )

1.31

t/m3

Cohesion ( C )

2.60

t/m2

For Local Shear failure ( C' = 2/3 * C)

1.73

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

2.500

Width of Footing B

1.8

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
10.0
m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d
i
+
x B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

N'q =

1.000

Sq=

1.004

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N = tan (PI/4 + /2) =


2

dc =
1.278
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F1.73*5.14*1.004*1.278*1 (1.77-1)*2.5*(1-1)*1.004*1*1 0.5*1.8*1.77*0*0.99*1*1*0.5 ]


{

11.410

0.000

0.000

1.925

11.410
2.5

1.925

6.489

or say

6.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.036

1.036

0.93

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.81/8-4

(81/790)

Bore Hole No

Sample No

Location

RW1

Depth of U.D.Sample(d)
Bulk Density( b )

3.000

1.82

t/m3

Moisture Content w in %

34.53

Dry Density (d )

1.35

t/m3

Cohesion ( C )

0.90

t/m2

For Local Shear failure ( C' = 2/3 * C)

0.60

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

4.200

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
115.0 m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d i + x B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

N'q =

1.000

Sq=

1.004

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N = tan (PI/4 + /2) =


2

dc =
1.365
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F0.6*5.14*1.004*1.365*1 + (1.82-1)*4.2*(1-1)*1.004*1*1 0.5*2.3*1.82*0*0.99*1*1*0.5 ]


{

4.226

0.000

0.000

3.444

4.226
2.5

3.444

5.135

or say

5.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.004

1.004

0.99

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.81/8-3

(81/750)

Bore Hole No

Sample No

Location

RW1

Depth of U.D.Sample(d)
Bulk Density( b )

3.000

1.84

t/m3

Moisture Content w in %

13.04

Dry Density (d )

1.63

t/m3

Cohesion ( C )

2.10

t/m2

For Local Shear failure ( C' = 2/3 * C)

1.40

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

4.200

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
115.0 m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d i + x B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

N'q =

1.000

Sq=

1.004

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N = tan 2 (PI/4 + /2) =

dc =
1.365
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

1
2.5

[F1.4*5.14*1.004*1.365*1 + (1.84-1)*4.2*(1-1)*1.004*1*1 0.5*2.3*1.84*0*0.99*1*1*0.5 ]


{

9.862

0.000

0.000

3.528

9.862
2.5

3.528

7.473

or say

7.0 t/m2

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.004

1.004

0.99

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.81/8-2

(81/720)

Bore Hole No

Sample No

Location

RW1

Depth of U.D.Sample(d)
Bulk Density( b )

3.000

1.87

t/m3

Moisture Content w in %

28.74

Dry Density (d )

1.45

t/m3

Cohesion ( C )

2.20

t/m2

For Local Shear failure ( C' = 2/3 * C)

1.47

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

4.200

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
115.0 m
SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

N'q =

1.000

Sq=

1.004

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N = tan (PI/4 + /2) =


2

dc =
1.365
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=
=

1
1

[F1.47*5.14*1.004*1.365*1 (1.87-1)*4.2*(1-1)*1.004*1*1 0.5*2.3*1.87*0*0.99*1*1*0.5 ]


{

10.355

3.654

0.000

7.796

or say

0.000

2.5
=

10.355

7.0 t/m2

3.654

2.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing

Sc

Sq

1.004

1.004

0.99

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

Rectangle

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

S.B.C.Calculations (as per I.S: 6403-1981)


RETAINING WALL IN KM81/8, 83/8, 83/10, 85/4, 92/8 AND 93/8 OF KAKINADA - AMALAPURAM NARASAPURAM FERRY ROAD IN E.G. DIST.
DATA:

KM.81/8-1

(81/680)

Bore Hole No

Sample No

Location

RW1

Depth of U.D.Sample(d)
Bulk Density( b )

3.000

1.88

t/m3

Moisture Content w in %

30.38

Dry Density (d )

1.44

t/m3

Cohesion ( C )

3.00

t/m2

For Local Shear failure ( C' = 2/3 * C)

2.00

t/m3

Angle of Internal Friction ( )

degr

< 280 LSF

0.00

degr

> 360 GSF

Shear Parameters:

Angleof Internal Friction(' = tan-(2/3*tan) :

Depth of Foundation Df

4.200

Width of Footing B

2.3

Depth of Water Table below GL

1.0

Factor of Safety

2.5

LENGTH of footing

:
115.0 m
1{
C
N'
S
d
i
+
q
(
N'
-1)
S
d i + x B b N' S d i W'} + (b-1)d
SBC=
c
c c c
q
q q q
F

F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000


q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1+0.2B/L 1+0.2B/L 1-0.4B/L

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)
N'c =

5.140

N'q =

1.000

Sq=

1.004

Shape Factors for RECTANGULAR Footing:


Sc=
1.004
Depth Factors :

N = tan (PI/4 + /2) =


2

dc =
1.365
dq=dv= 1
Inclination Factors ic = iq = i =

W' = Water Table Correction factor =

N' = 0.000
S=

0.99

1.000

as angle of inclination is 00
0.5

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


=

14.088

3.696

0.000

9.331

or say

0.000

2.5
=

14.088
2.5

9.0 t/m2

3.696

SBC= 1{ C N'c Sc dc ic + q ( N'q-1) Sq dq iq + x B b N' S d i W'} + (b-1)d


F
F = Factor of safety 2.5 as per cl 706.3.1.1 of IRC:78-2000
q = Effective surcharge at the base level of foundation
N'c, N'q, N' = Bearing capacity factors from Table 1 of IS:6403
S - Shape factors from Table : 2 of IS:6403
Continous strip footing
Rectangle

Sc

Sq

1.004

1.004

0.99

Square

1.3

1.2

0.8

Circle

1.3

1.2

0.6

d - Depth factors (This correction is to be applied only when back filling is done with proper compaction)
dc = 1 + 0.2 Df / B x sqrt( N )

dq = dv = 1 for < 100

dq = dv = 1 + 0.1 Df / B x sqrt( N ) > 10 0

N = tan 2 (PI/4 + /2)

i - Inclination factor
If Dw > Df + B then W' = 1
If Dw < Df then W' = 0.5
W' = Water Table Correction factor
If Df < Dw < (Df + B) then W' = 0.5 to 1 (to be obtained by linear interpolation)

Asst. Executive Engineer (R&B),

Deputy Executive Engineer (R&B),

R&B Section, Malikipuram

R&B Subdivision, Razole

Executive Engineer (R&B),

Superintending Engineer (R&B),

R&B Division, Amalapuram

R&B Circle, Kakinada

BEARING CAPACITY FACTORS


(TABLE:1 IS:6403-1981
DEG(Pi)
##
0
##
1
##
2
4,5
3
##
4
###
5
##
6
###
7
8#
13,14
9
10#
16,17
11
12#
13#
20,21
14
15#
16#
24,25
17
18#
19#
,28,29
20
21#
22#
32,33
23
24#
25#
26#
27#
38,39
28
29#
30#
31#
32#
33#
34#
35#
36#
37#
38#
39#
40#
45#
50#

Nc
5.140
5.410
5.680
5.950
6.220
6.490
6.862
7.234
7.606
7.978
8.350
8.876
9.402
9.928
10.454
10.980
11.750
107.230
13.290
14.060
14.830
16.008
17.186
18.364
19.542
20.720
22.604
24.488
26.372
28.256
30.140
33.336
36.532
39.728
42.924
46.120
51.958
57.796
63.634
69.472
75.310
138.880
266.890

Nq
1.000
1.114
1.228
1.342
1.456
1.570
1.750
1.930
2.110
2.290
2.470
2.764
3.058
3.352
3.646
3.940
4.432
4.924
5.416
5.908
6.400
7.252
8.104
8.956
9.808
10.660
12.208
21.496
15.304
16.852
18.400
21.380
24.360
27.340
30.320
33.300
39.480
45.660
51.840
58.020
64.200
134.880
319.070

Nr
0.000
0.090
0.180
0.270
0.360
0.450
0.604
0.758
0.912
1.066
1.220
1.506
1.792
2.078
2.364
2.650
3.198
3.746
4.294
4.842
5.390
6.488
7.586
8.684
9.782
10.880
13.184
15.488
17.792
20.096
22.400
27.526
32.652
37.778
42.904
48.030
60.306
72.582
84.858
97.134
109.410
271.760
762.890

Potrebbero piacerti anche