Flocrete SP66M2 is formulated from selected polymers
specially designed to enable the water content of the
concrete to perform more eec vely.
This eect can be used to improve workability, to increase
ul mate strengths or to facilitate a reduc on in the
cement content while sustaining mix proper es.
Flocrete SP66M2 has strong workability reten on which
helps in long distance and hot weather concrete deliveries,
and is par cularly suitable for ready-mix concrete.
Brown liquid
Freezing point:
-2C
Specific gravity:
1.151 0.02
Chloride content:
BS 5075
Nil
Air entrainment:
Applications
Long distance and hot weather concrete deliveries.
Where high workability reten on and retarda on are
of prime importance.
To produce high quality concrete of improved
durability and water ghtness.
Advantages
Higher strength with same cement content.
Minimising segrega on problems by improving
cohesion.
Excellent slump reten on proper es.
Improved workability reduces placing and compac on
problems.
Cold joints can be avoided by extending ini al and
final concrete se ng me.
Saving
cement
without
aec ng
strength
specifica ons.
More durable concrete by considerable reduc on in
permeability.
Compatibility
Flocrete SP66M2 can be used with all types of
Portland cement and cement replacement materials.
Flocrete SP66M2 is compa ble with other DCP admixtures
used in the same concrete mix.
If more than one type of admixture will be used in the
concrete mix, they must be dispensed to the concrete
separately.
Standards
Flocrete SP66M2 complies with ASTM C494, Type B, D
and G, depending on the dose.
Method of Use
Flocrete SP66M2 should be added to the concrete with
the mixing water to achieve op mum performance.
An automa c dispenser should be used to dispense the
correct quan ty of Flocrete SP66M2 to the concrete mix.
Dosage
The guidance dosage is between 0.70 - 1.80 litre per 100
kg of cemen ous materials in the mix, including GGBFS,
PFA or microsilica.
Effects of Over Dosage
Flocrete SP66M2 over dosage will cause the following:
Significant increase in retarda on.
Increase in workability.
Ul mate concrete strength will not be adversely aected
and will generally be increased provided that proper
concrete curing is maintained.
Setting Time
Although the se ng me is dependent on the dosage
of Flocrete SP66M2, the following factors should be
considered:
Flocrete SP66M2
i. Retarda on is increased with a lower level of tricalcium in the cement.
ii. Lower temperatures will delay the se ng me.
iii. SRC cement gives higher retarda on level than
ordinary cement.
iv. Using more than one type of admixture in the same
concrete mix could aect the si ng me.
v. Retarda on level is increased when cement
replacement materials are used in the concrete mix.
Cleaning
Flocrete SP66M2 can be washed immediately by cold
water.
Packaging
Concrete admixtures.
Surface treatments
Grouts and anchors.
Concrete repair.
Flooring systems.
Protec ve coa ngs.
Sealants.
Waterproofing.
Adhesives.
Tile adhesives and grouts.
Building products.
Structural strengthening.
Cautions
Health and Safety
Flocrete SP66M2 is not classified as hazardous material.
Flocrete SP66M2 should not come into contact with skin
and eyes.
In case of contact with eyes wash immediately with
plenty of water and seek medical advice promptly.
For further informa on refer to the Material Safety Data
Sheet.
Fire
Flocrete SP66M2 is nonflammable.
01-0219-A-2016
Note:
t
,