Plugs and Receptacles

Industrial Heavy Duty Interlocked


Hazardous

4P

Description

Page No.

Application/Selection

see pages 13001301

Interlocked Receptacle with


H.P. Rated Switch
Technical Data
FSQC 30A & 60A / APJ Plugs
FSQC 100A / APJ Plugs

see page 1302


see pages 13021303
see page 1304

Factory Sealed Switch


BHR 30A, 60A & 100A / BHP Plugs
SRD 30A & 60A / SP Plugs

see pages 13081309


see page 1310

Circuit Breaker
EBBR 30A, 60A, 100A
EPC, 30A, 60A, 100A, 200A
EPCB 30A, 60A, 100A
DBR 30A, 60A, 100A

see pages 13051307


see page 1312
see pages 13151316
see page 1317

4P

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1299

4P

CHS Controls AB

Plugs and Receptacles

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

Industrial Heavy Duty Interlocked


Application and Selection
Hazardous
Applications:
Where extra protection is a requirement.
Interlocked units provide dead front
receptacles; connection cannot be made
or broken when unit is under load.
In areas made hazardous by flammable
vapors, gases or dusts; to supply power
for portable electrical equipment and
provide safe disconnect means and
short circuit protection.

Options:

Considerations for
Selection:
Environmental:
The environment of the enclosure location
in terms of NEC/CEC compliance and
NEMA/EEMAC type required.
Material and construction to withstand
rough usage and atmospheric conditions.

Special polarity arrangements, material


options, accessories, and optional
arrangements of enclosure interiors are
available to meet specific application
needs. See listing pages for details.

Electrical:
Sufficient current-carrying capacity to
meet load requirements.
Compatibility with electrical system (new
or existing installation).
Interchangeability of plugs with other
hazardous and non-hazardous area
receptacles.
Function:
Switch vs. circuit breaker.

Quick Selector Chart


NEC/CEC & NEMA/EEMAC
Compliances
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 4, 7BCD, 9FG, 12

Receptacles
Interlocked With
Factory
sealed
switch

Page
See pages 13081309

Mating
Plugs
BHP

Electrical
Rating
30, 60, 100 amp.
480VAC
2-wire, 3-pole
3-wire, 4-pole
4-wire, 5-pole

DBR

NEC: Class II, Division 1 and 2, Groups F, G


NEC: Class III
NEMA/EFC: 3, 9FG, 12
CEC: Class II, Division 1 and 2, Group G
CEC: Class III
Encl. 3, 5

Circuit
breaker

See page 1317

APJ/NPJ

Circuit breaker:
100 amp. frame size
250VDC/600VAC
Receptacle:
30, 60, 100 amp.
2-wire, 3-pole
3-wire, 3-pole
3-wire, 4-pole

EBBR

Class I, Division 1 and 2, Groups B, C, D


Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 3R, 7BCD, 9FG, 12

Circuit
breaker

See pages 13051307

APJ/NPJ

Receptacle:
30, 60, 100, 150 amp.
3-wire, 4-pole

EPC

NEC: Class I, Division 1 and 2, Groups C, D


NEC: Class II, Division 1 and 2, Groups F, G
NEC: Class III
NEMA: 3, 7CD, 9FG, 12
CEC: Class I, Division 1 and 2, Groups C, D
CEC: Class II, Division 1 and 2, Group G
CEC: Class III
Encl. 3, 4

Circuit
breaker

See pages 13121314

APJ/NPJ

Circuit breaker:
100 amp. frame size
480VAC/250VDC
Receptacle:
30, 60, 100 amp.
2-wire, 3-pole
3-wire, 4-pole

EPC

Class I, Division 1 and 2, Group D


Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 7D, 9FG, 12

Circuit
breaker

See pages 13121314

DP

Circuit breaker:
225 amp. frame size
600VAC/250VDC
Receptacle:
200 amp.
3-wire, 4-pole

EPCB

NEC: Class I, Division 1 and 2, Groups B, C, D


NEC: Class II, Division 1 and 2, Groups F, G
NEC: Class III
NEMA: 3, 7BCD, 9FG, 12
CEC: Class I, Division 1 and 2, Groups B, C, D
CEC: Class II, Division 1 and 2, Group G
CEC: Class III
Encl. 3, 4

Circuit
breaker

See pages 13151316

APJ/NPJ

Circuit breaker:
100 amp. frame size
600VAC/250VDC
Receptacle:
30, 60, 100 amp.
2-wire, 3-pole
3-wire, 4-pole

4P

Series
BHR

1300

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

4P

Plugs and Receptacles


Industrial Heavy Duty Interlocked
Quick Selector and Interchangeability Chart
Hazardous
Quick Selector Chart
Series
FSQ

SRD

NEC/CEC & NEMA/EEMAC


Compliances
NEC: Class I, Division 1 and 2, Groups B, C, D
NEC: Class II, Division 1 and 2, Groups F, G
NEC: Class III
NEMA: 3, 7BCD, 9FG, 12
CEC: Class I, Division 1 and 2, Groups B, C, D
CEC: Class II, Division 1 and 2, Groups G
CEC: Class III
Encl. 3, 5

Receptacles
Interlocked With
Switch

Class I, Division 1 and 2, Group D


Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 7D, 9FG, 12

Factory
sealed
switch

Page
See pages
13021304

See pages
13101311

Mating
Plugs
APJ/NPJ

Electrical
Rating
30A 250V/20A 600VAC
2-wire, 3-pole
3-wire, 4-pole
60 & 100 amp.
2-wire, 3-pole
3-wire, 4-pole

5P

30 & 60 amp. 480VAC


2-wire, 3-pole
3-wire, 4-pole
4-wire, 5-pole

Interchangeability Chart
Many of the plugs listed in this section can
be used interchangeably with receptacles
from other sections, both in hazardous and
non-hazardous areas, provided electrical
rating and style of plug and receptacle
are the same. The following table is a
summary of possible combinations.

Listed in
Section

Plug &
Receptacle
Electrical
Rating

AR, NR
EPC, EPCB,
DBR, EBBR, CSR,
FSQC

1P
4P

30, 60, 100 amp.


3-wire, 4-pole

APJ/NPJ

NBR, NSR,
WSR, CSR,
WSRD, WSRDW,
WSQC,
WSRD SM S901

3P

30, 60, 100 amp.


3-wire, 3-pole
3-wire, 4-pole

BHP

BHR
SRD

4P

30, 60, 100 amp.


2-wire, 3-pole
3-wire, 4-pole
4-wire, 5-pole

SP

BHR
SRD

4P

30, 60 amp.
2-wire, 3-pole
3-wire, 4-pole
4-wire, 5-pole

Plugs
Shown in
Section 4P

Can be Used
with These
Receptacle
Series

CAUTION: To reduce the risk of ignition of hazardous


atmospheres, do not use plugs or receptacles in
Class II, Group F locations that contain electrically
conductive dusts.

4P

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1301

FSQC Arktite Dead Front


Interlocked Receptacles
and Switches

4P

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 7BCD, 9FG, 12

APJ/NPJ Arktite Plugs


Applications:
FSQC dead front switched interlock
receptacles are used:
To supply power to portable electrical
equipment such as hand lamps, lighting
systems, power tools, conveyors,
welders and similar equipment.
In areas which are hazardous due to the
presence of flammable vapors or gases
and combustible dusts.
In damp, wet or corrosive locations.
Indoors or outdoors at petroleum
refineries, chemical and petrochemical
plants and facilities for processing and
handling grain, flour and starch.

Features:

Options:

Compatible with Arktite APJ aluminum


and NPJ Krydon plugs
Switch cannot be turned "ON" until plug
is fully inserted and rotated
Plug cannot be withdrawn under load
Cover cannot be removed when switch
is "ON"
Satisfies OSHA lockout tagout requirement
Smallest mounting footprint for interlocks

Description
Suffix
Special polarity, receptacle
interior rotated 221/2....................... S4

Interchangeability of Plugs
with Other Hazardous and
Non-hazardous Location
Receptacles:
Plugs listed for FSQC receptacles on
1043 are standard APJ/NPJ plugs. Other
standard APJ/NPJ of the same rating,
style and number of poles may be used
with FSQC receptacles as well as with
DBR, EBBR, EPC and EPCB receptacles
listed in Section 2P and 4P.
As a result, portable equipment suitable
for the location and equipped with the
proper plug can be used with AR series
receptacles for non-hazardous areas,
EBBR, EPC, EPCB, and FSQC
receptacles for Class I hazardous
locations; DBR receptacles for Class II
hazardous locations.

Certifications and
Compliances:
NEMA 3, 7BCD, 9FG, 12
NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class I, Zone 1, Group IIB + Hydrogen
Class II, Division 1 & 2, Groups F, G
Class III
ANSI/UL Standards: 1010 UL Listed
CSA Standards: C22.2 No. 30 cUL Listed
& C22.2 No. 159

Dimensions
In Inches:
30 Amp FSQC

60 Amp FSQC

Materials:

4P

Enclosure copper-free aluminum


Cover and spring door copper-free
aluminum
Insulator Krydon
Contacts brass

Dimensions
Cat. #

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

1302

www.crouse-hinds.com

FSQC2320, 3320
FSQC2430, 3430
FSQC2390, 3390

US: 1-866-764-5454

CAN: 1-800-265-0502

Maximum Dimensions
a
c
d

43/4

93/4

Copyright 2010 Cooper Crouse-Hinds

31/8

53/4

/8

FSQC Arktite Dead Front


Interlocked Receptacles
and Switches

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 7BCD, 9FG, 12

4P

APJ/NPJ Arktite Plugs


FSQC Receptacles
With Spring Door Through Feed Hubs

Horsepower Rating:
Amps
30A
60A

120V

Amps
30A
60A

120V

Single Phase
240V
480V

600V

71/2

71/2

10

25

30

Three Phase
240V
480V
71/2
10

600V

15
25

15
30

Ordering Information:
Amps

Hub
/4"

30A
1"
60A

11/2"

Config.

Description

Cat. #

Matching Plug

2W3P
3W4P
2W3P
3W4P
2W3P
3W4P

2-Pole Switch
3-Pole Switch

FSQC2320
FSQC2430
FSQC3320
FSQC3430
FSQC5630
FSQC5640

APJ3385
APJ3485
APJ3385
APJ3485
APJ6385
APJ6485

2-Pole
3-Pole
2-Pole
3-Pole

Switch
Switch
Switch
Switch

FSQC for Use with Magnetic Motor Starters or Contactors


FSQC units listed below operate in the same way as standard units but are intended only for
use with magnetic motor starters or contactors (see Wiring Diagram 1).
Receptacles have leads for splicing to conductors from the load side of contactor. The
switch actuated by the plug is wired into the starter or contactor coil circuit and controls
only this circuit. The starter or contactor is energized only when the plug is fully inserted and
rotated to close the switch. Since the plug is inserted or withdrawn only when the switch is
open, the circuit cannot be made or broken under the load.
Plugs used are standard APJ units and special polarity units listed are recommended where
interchange with devices for other wiring systems is possible.

FSQC Receptacles

Wiring Diagram 1
FSQC2390 and 3390 only

With Spring Door Through Feed Hubs

Special Polarity Configuration


3
3W, 4P
/4
FSQC2390 S4
3W, 4P
1
FSQC3390 S4

Cable Dia.

Mating Plug
Cat. #

0.39-1.20
0.55-0.70
0.70-0.85

APJ3485
NPJ3483
NPJ3484

0.39-1.20
0.55-0.70
0.70-0.85

APJ3485 S4
NPJ3483 S4
NPJ3484 S4

www.crouse-hinds.com

US: 1-866-764-5454

4P

No. of
Hub
Receptacle
Poles
Size
Cat. #
Standard Configuration
3
/4
FSQC2390
3W, 4P
3W, 4P
1
FSQC3390
3W, 4P
1

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se
CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1303

Applications:

Materials:

To supply power to portable or fixed


electrical equipment such as welders,
pumps, motors, machine tools,
conveyors, oil rigs, mixers, grain
elevators, petroleum refineries, chemical
and petrochemical plants
In hazardous areas containing
flammable vapors or gases and
combustible dusts
In damp, wet or hosedown
environments
In highly corrosive locations

Features:

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 3R, 4, 4X*, 7BCD, 9FG, 12
Explosionproof

100 Amp FSQ Dead Front


Interlocked

4P

NEMA Type 4 watertight


Suitable for Group B
Compact housing
Simple operation
Compatible with Arktite APJ aluminium
and NPJ Krydon plugs
H.P.-rated enclosed switch
4 mounting feet can be rotated for
flexibility in positioning to surface
Wiring channel provided under switch
for easy wire routing to terminals
Dual bottom-feed hubs and one top hub
for convenient feed-through installation
Bread-loose fork lugs case in place for
easy removal of cover

Certifications and
Compliances:

Body copper-free aluminum


Cover copper-free aluminum
Locking collar Feraloy iron alloy
Insulator Krydon material
Contacts brass

Options:
Description
Suffix
Special polarity receptacle
interior rotated 221/2 to right......... S4
(example: FSQC61040 S4)
NEMA 4X epoxy powder coatedS752
(example: FSQC61040 S752)
Auxiliary contact............................ S483
Breather/Drain............................... S756V

Safety First:
Power cannot be turned "on" until plug
is fully inserted and Uni-Loc collar is
rotated
When Uni-Loc collar is in "on" position,
plug is locked in place to prevent
disengagement under load
Cover cannot be removed while switch
is "on"
Cover-Loc design prevents switch from
being turned "on" while cover is removed
Uni-Loc collar aligns with lug on housing
to permit OSHA lockout/tagout in the
"off" position

Electrical Rating:

NEMA 3, 3R, 4, 4X*, 7BCD, 12


Class I, Divisions 1 and 2, Groups B, C, D
Class I, Zone 1, Group IIB + H2
Class II, Divisions 1 and 2, Groups F, G
Class III
ANSI/UL Standards: 1010 and 98 UL
Listed
cUL Listed, CSA Standard C22.2 No. 30,
C22.2 No. 159
*NEMA 4X when ordered with suffix S752.

100A, 600VAC

Ordering Information:
Hub HP
Rating Config. Size Rating
100A,
600
VAC

3W4P

2"

Cat. #

50 HP
@ 600V, FSQC61040
480V

Dimensions

4P

In Inches:

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

1304

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

NEMA 4
Watertight

EBBR Series Interlocked Arktite


Receptacles with Circuit
Breakers
30, 60, 100 Amp Interlocked Receptacles

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 3R, 7BCD, 9FG, 12
Explosionproof

Dust-Ignitionproof
Raintight
Wet Locations

4P

Applications:

Standard Finishes:

EBBR interlocked receptacles with circuit


breakers are used:
As a service outlet for portable
equipment indoors or outdoors in
damp, wet, corrosive locations, without
the need for a protective shelter.
In areas which are hazardous due to
flammable vapors, gases or combustible
dust, e.g., refineries, chemical plants,
and other processing and handling
facilities of a hazardous nature.
In areas where frequent washdowns are
necessary or where heavy rain or water
spray is prevalent.

Copper-free aluminum natural


Fiberglass-reinforced polyester
natural (red)
Brass natural
Leaded red brass electro-tin-plated
Stainless steel natural

Electrical Rating Ranges:


Circuit breakers 20150 amps
Receptacles 30, 60, 100, 150 amp
3-wire, 4-pole configuration

Options:

Features:

Grounding:
Simple, straightforward installation of
breaker on pre-drilled mounting plate
within enclosure.
Neoprene cover gasket permanently
attached to the cover seals out moisture.
Bodies have top drilled and tapped
entrance for power conduit (11/2") plus
one at the top and one at the bottom for
a breather and drain (1/2"). Breather and
drain entrances are plugged.
Tap-on mounting feet.

Certifications and
Compliances:
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 3R, 7BCD, 9FG, 12
UL Standard: 1203

EBBR interlocked receptacles and


matching plugs are provided with an
extra grounding pole for attaching a
grounding wire. In addition, direct
connection is provided between
receptacle and metallic plug and the
grounding pole. If a compatible
non-metallic plug made of Krydon
fiberglass-reinforced polyester material
is used, grounding is accomplished
through the extra grounding pole only.
If a separate grounding wire is not
installed in the enclosure, grounding
is accomplished through the
conduit system.
Caution: To reduce the risk of ignition of hazardous
atmospheres, do not use plugs or receptacles in Class
II, Group F locations that contain electrically conductive
dusts.

Standard Materials:
Body, cover, and receptacle copperfree aluminum
Contact insulator (receptacles and
plugs) fiberglass-reinforced polyester
Receptacle contacts leaded red brass
Pressure contacts (plugs) brass
Operating handle copper-free
aluminum
Operating shafts and bushings
stainless steel
Interior parts heavy gauge sheet steel,
zinc plated
Cover bolts, washer and retractile
springs stainless steel

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

4P

Rugged, corrosion resistant, cast


copper-free aluminum construction.
Accepts compatible Arktite plug of same
rating and configuration.
Mechanical interlock mechanism for
dead front construction.
Receptacles are mechanically interlocked
with circuit breakers to provide
disconnect means, short circuit
protection and thermal time delay
overload protection.
A spring door receptacle, located at the
bottom of the unit, is mechanically
interlocked with the circuit breaker
operating mechanism for safe and
dependable operation.
Plug and receptacle contacts cannot be
made or broken under load. The circuit
breaker cannot be closed until the plug is
fully inserted and the plug cannot
be withdrawn unless the breaker is
de-energized.
Operating handles can be padlocked in
either "ON" or "OFF" positions. Breakers
are trip-free of the handles and will open
under short circuit or overload even if the
handle is locked in the "ON" position.
Component operating handles located
through the right side wall of the body
permits visual confirmation of correct
component assembly and operation.
Total compliance to the wiring and
room requirements of the National
Electrical Code.
Semi-clamshell enclosure design, with an
external machined flat joint flamepath
between body and cover makes interior
components easily accessible.
Minimum enclosure-to-enclosure spacing
with little interference between the opened
cover and an adjacent enclosure.
Copper-free aluminum hinges allow the
cover to swing well out of the way.
Stainless steel, quick release, captive,
hex head cover bolts. Stainless steel
springs provide clear indication cover
bolts are fully retracted from body.
Versatile, internal operating mechanisms
allow for field adjustment to accommodate
popular manufacturers' breakers.

The following options are available from


the factory by adding suffix to the Cat. #:
Description
Suffix
Receptacle interior rotated 221/2
to right (viewed from face) and
plug changed to match.................S4
Breather (ECD13) at top, Drain
(ECD11) at bottom........................ S198V
Group B Breather and Drain......... S756V
External Powder Epoxy Finish...... S752

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

Copyright 2010 Cooper Crouse-Hinds

1305

4P

EBBR Series Interlocked Arktite


Receptacles with Circuit
Breakers
30, 60, 100 Amp Interlocked Receptacles

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 3R, 7BCD, 9FG, 12
Explosionproof

Dust-Ignitionproof
Raintight
Wet Locations

Interchangeability of Plugs with Other


Hazardous and Non-hazardous Location
Receptacles:
Plugs listed for use with EBBR receptacles are standard Arktite
APJ/NPJ plugs. Standard APJ/NPJ and also CPH plugs of the
same rating, style and number of poles may be used with EBBR
receptacles, as well as with DBR, EPC and EPCB receptacles
listed in Section 4P of the catalog.
As a result, portable equipment suitable for the location and
equipped with the proper plug can be used with AR/NR series
receptacles for non-hazardous locations; EBBR, EPC and EPCB
receptacles for Class I and II hazardous locations; and DR and
DBR receptacles for Class II hazardous locations.

Complete EBBR receptacle with circuit breaker installed.

Ordering Information:
Receptacle
With Spring
Door Housing
30 Amp
3-wire
4-pole
Style 2
60 Amp
3-wire
4-pole
Style 2
100 Amp
3-wire
4-pole
Style 2

4P

150 Amp
3-wire
4-pole
Style 2

Hub
Size
(In.)
1 /2
1

11/2

11/2

11/2

Circuit Breaker
Rating
Amps

Without Circuit
Breaker Cat. #

w/Cutler-Hammer
Breaker

w/G.E. Breaker
EBBRA304
EBBRA304
EBBRA304
EBBRA304

WT20
WT30
WT40
WT50

3
3
3*
3*

TT20
TT30
TT40
TT50

w/Square D Breaker

3-pole
480VAC+
or
250 VDC
3-pole
480VAC+
or
250 VDC

20
30
40
50

EBBRA304
EBBRA304
EBBRA304
EBBRA304

EBBRA304
EBBRA304
EBBRA304
EBBRA304

3
3
3*
3*

EBBRA304
EBBRA304
EBBRA304
EBBRA304

DT20
DT30
DT40
DT50

3
3
3*
3*

50
60
70
90
100

EBBRA604
EBBRA604
EBBRA604
EBBRB604
EBBRB604

EBBRA604 WT50 3
EBBRA604 WT60 3
EBBRA604 WT70 3*
EBBRB604 WT90 3*
EBBRB604 WT100 3*

EBBRA604 TT50 3
EBBRA604 TT60 3
EBBRA604 TT70 3*
EBBRB604 TT90 3*
EBBRB604 TT100 3*

EBBRA604 DT50 3
EBBRA604 DT60 3
EBBRA604 DT70 3*
EBBRB604 DT90 3*
EBBRB604 DT100 3*

3-pole
480VAC+
or
250 VDC

50
60
70
90
100

EBBRA104
EBBRA104
EBBRA104
EBBRB104
EBBRB104

EBBRA104 WT50 3
EBBRA104 WT60 3
EBBRA104 WT70 3
EBBRB104 WT90 3
EBBRB104 WT100 3

EBBRA104 TT50 3
EBBRA104 TT60 3
EBBRA104 TT70 3
EBBRB104 TT90 3
EBBRB104 TT100 3

EBBRA104 DT50 3
EBBRA104 DT60 3
EBBRA104 DT70 3
EBBRB104 DT90 3
EBBRB104 DT100 3

3-pole
480VAC+
or
250 VDC

100
125
150

EBBRB154
EBBRB154
EBBRB154

EBBRB154 WT100 3
EBBRB154 WT125FDB 3
EBBRB154 WT150FDB 3

+Enclosures with 600 Volt circuit breakers are available. Add suffix "FDB" Ex: EBBRA304 WT20FDB-3.
*Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only, as higher trip rating may not protect wiring.
150A also available in A size enclosure for areas with space constraints (ie EBBRA154).
Caution: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

1306

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 3R, 7BCD, 9FG, 12
Explosionproof

EBBR Series Interlocked Arktite


Receptacles with Circuit
Breakers
30, 60, 100 Amp Interlocked Receptacles

Amps

Cable O.D.
Range

3-wire, 4-pole Cat. #


Krydon
Aluminum material

0.60 to 1.20
0.55 to 0.70
0.70 to 0.85

APJ3485

30

0.75 to 1.45
0.75 to 1.07
1.07 to 1.35

APJ6485

60

1.00 to 1.70
0.93 to 1.21
1.21 to 1.50

APJ10487

100

Dust-Ignitionproof
Raintight
Wet Locations

4P

APJ and NPJ Arktite Plugs

NPJ3483
NPJ3484
NPJ6484
NPJ6485
NPJ10486
NPJ10487

Aluminum APJ series

Krydon material NPJ series


(non-metallic)

Both APJ and NPJ series plugs may be used with EBBR series
interlocked receptacles.

Dimensions
In Inches:

EBBRA
Amps
30
60
100
150

EBBRB

19.40
19.40
19.40
19.40

22.85
23.95
24.70
24.70

17.25
17.25
17.25
17.25

14.50
14.50
14.50
14.50

26.90
26.90
26.90

31.45
32.20
32.20

24.75
24.75
24.75

22.00
22.00
22.00

4P

Caution: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or
receptacles in Class II, Group F locations that contain electrically conductive dusts.

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1307

4P

BHR Dead Front Interlocked


Receptacles with Factory
Sealed Switch
BHP Plugs

Applications:

Standard Materials:

BHR dead front interlocked receptacles


and switches with BHP plugs are used:
To supply power to portable electrical
equipment such as motor-generator
sets, compressors, heating and cooling
units, lighting systems, conveyors, and
similar equipment
Primarily in areas which are hazardous
due to the presence of hydrogen or
gases, or vapors of equivalent hazard
such as manufactured gas
In damp, wet, or corrosive locations
Indoors or outdoors in hydrogen areas of
process industries, missile bases where
hydrogen fuel is used, and gas
manufacturing plants

Receptacle housings copper-free


aluminum
Seals malleable iron
Plug exteriors copper-free aluminum
Insulation high impact glass filled
phenolic
Contacts brass

Dust-Ignitionproof
Raintight
Wet Locations

Standard Finishes:
Copper-free aluminum natural
Malleable iron electrogalvanized and
aluminum lacquer
Phenolic natural (black)
Brass silver plated
BHR/BHP in use.

Options:

Features:

4P

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 4, 7BCD, 9FG, 12
Explosionproof

BHR receptacles feature a built-in rotary


switch which is operated automatically
when the plug is inserted and withdrawn.
The switch, capable of making and
breaking the circuit at full rated load, is
operated by a helical blade in the center
of the plug
The plug and receptacle contacts cannot
be made or broken under load. When the
plug is inserted, the plug and receptacle
contacts engage before the switch
closes. When the plug is withdrawn, the
switch opens before the plug and
receptacle contacts disengage. This
sequence of operation provides
maximum safety in a dead front
receptacle. Arcing is isolated in a flame
and dust-tight chamber
Operation is simple, safe and positive. To
disconnect the portable device, the plug
fastening ring is unscrewed and the plug
simply pulled straight out. No separate
interlock device or operating handle need
be actuated
Positive engagement without
mismatching is assured by a distinct
physical polarization of the plug and
receptacle in every rating
Plugs are furnished with pressure
terminations. Receptacles are furnished
with flexible leads for splicing to the
supply conductors. A large threaded
cover provides access to the wiring
compartment
As shown in the listings, assemblies are
available for top, bottom or through feed
conduit arrangements in 3/4" to 2" sizes

Special polarity where two or more


receptacles of the same ampere rating
and number of poles are to be installed
in the same areas for use on different
voltages, alternate polarizations can be
furnished. Details on request.

Electrical Rating Ranges:


30, 60 and 100 amperes, 480VAC

Grounding:
BHR receptacles and BHP plugs are
provided with an extra grounding pole. In
plugs, provision is made for attachment of
the grounding wire to the grounding pole.
In addition, direct connection is provided
between the plug and receptacle
housings and the grounding pole. In the
receptacle, grounding is accomplished
through the conduit system
CAUTION: To reduce the risk of ignition of hazardous
atmospheres, do not use plugs or receptacles in Class
II, Group F locations that contain electrically conductive
dusts.

Dimensions
In Inches:

BHR/BHP separated
showing helical driver.

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

Certifications and
Compliances:

Class I, Division 1 and 2, Groups B, C, D


Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 4, 7BCD, 9FG, 12
ANSI/UL Standard: 1010

1308

www.crouse-hinds.com

US: 1-866-764-5454

BHR/BHP

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

BHR only

BHR Dead Front Interlocked


Receptacles with Factory
Sealed Switch

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 4, 7BCD, 9FG, 12

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

4P

BHP Plugs, 480 VAC, 60400 hertz


Receptacles
Receptacles are supplied ready to install with a threaded cap. Through feed hubs are standard.
Sealing fittings, nipples and closure plugs ordered separately depending on application. Receptacles
can be configured for Top Feed, Bottom feed or Through feed.
Amps

Hub Size (In.)

Cat. #

30

2-wire,
2-wire,
3-wire,
3-wire,
4-wire,
4-wire,

Config.
3-pole
3-pole
4-pole
4-pole
5-pole
5-pole

/4
1
3
/4
1
1
11/4

BHRC3382N
BHRC3383N
BHRC3482D
BHRC3483D
BHRC3583 NW
BHRC3584 NW

60

2-wire,
2-wire,
3-wire,
3-wire,
4-wire,
4-wire,

3-pole
3-pole
4-pole
4-pole
5-pole
5-pole

11/4
11/2
11/4
11/2
11/4
11/2

BHRC6384N
BHRC6385N
BHRC6484D
BHRC6485D
BHRC6584 NW
BHRC6585 NW

100

2-wire,
2-wire,
3-wire,
3-wire,
4-wire,
4-wire,

3-pole
3-pole
4-pole
4-pole
5-pole
5-pole

11/4
11/2
11/2
2
11/2
2

BHRC10384N
BHRC10385N
BHRC10485D
BHRC10486D
BHRC10585 NW
BHRC10586 NW

Plugs
Plugs mate to BHR receptacles. Plugs are supplied with threaded locking ring that threads onto
receptacle housing for secure connection and environmental seal. Mechanical external cord grip
and neoprene bushing provided for secure cord retention and environmental seal.
Amps

Cable Dia.

Cat. #

30

2-wire,
2-wire,
3-wire,
3-wire,
4-wire,
4-wire,

Config.
3-pole
3-pole
4-pole
4-pole
5-pole
5-pole

.500 - .875
.875 - 1.375
.500 - .875
.875 - 1.375
.500 - .875
.875 - 1.375

BHP3383N
BHP3385N
BHP3483D
BHP3485D
BHP3583 NW
BHP3585 NW

60

2-wire,
2-wire,
3-wire,
3-wire,
4-wire,
4-wire,

3-pole
3-pole
4-pole
4-pole
5-pole
5-pole

.500 - .875
.875 - 1.375
.500 - .875
.875 - 1.375
.875 - 1.375
1.375 - 1.875

BHP6383N
BHP6385N
BHP6483D
BHP6485D
BHP6585 NW
BHP6587 NW

100

2-wire,
2-wire,
3-wire,
3-wire,
4-wire,
4-wire,

3-pole
3-pole
4-pole
4-pole
5-pole
5-pole

.875 - 1.375
1.375 - 1.875
.875 - 1.375
1.375 - 1.875
.875 - 1.375
1.375 - 1.875

BHP10385N
BHP10387N
BHP10485D
BHP10487D
BHP10585 NW
BHP10587 NW

4P

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1309

SRD Dead Front Interlocked


Receptacles with Factory
Sealed Switch

4P

Cl. I, Div. 1 and 2, Group D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 7D, 9FG, 12
Explosionproof

4P

SP Plugs, 480 VAC, 60400 hertz


Applications:

Standard Materials:

SRD dead front interlocked receptacles,


switches, and SP plugs are used:
To supply power to portable electrical
equipment such as motor-generator
sets, compressors, heating and cooling
units, lighting systems, conveyors and
similar equipment
In areas which are hazardous due to the
presence of flammable vapors or gases
and combustible dusts
In damp, wet or corrosive locations
Indoors or outdoors at petroleum
refineries, chemical and petrochemical
plants, as well as facilities for processing
and handling grain, flour and starch

Back box Feraloy iron alloy


Threaded cover copper-free aluminum
Receptacle housings and plug exteriors
copper-free aluminum
Insulation high impact glass filled
phenolic
Contacts brass

Features:

Options:

SRD receptacles feature a built-in rotary


switch that operates automatically when
the plug is inserted and withdrawn. The
switch, capable of making and breaking
the circuit at full rated load, is operated
by a helical blade in the center of the
plug.
The plug and receptacle contacts cannot
be made or broken under load. When the
plug is inserted, the plug and receptacle
contacts engage before the switch
closes. When the plug is withdrawn, the
switch opens before the plug and
receptacle contacts disengage. This
sequence of operation provides the
maximum safety of a dead front
receptacle. Arcing is isolated in a flame
and dust-tight chamber.
Operation is simple, safe and positive.
To disconnect the portable device, the
plug is simply pulled straight out. No
separate interlock device or operating
handle need be actuated.
Positive engagement without mismating
is assured by a distinct physical
polarization of plug and receptacle in
every rating.
Plugs are furnished with pressure
terminations. Receptacles are furnished
with flexible leads for splicing to the
supply conductors. A threaded cover at
the top provides access to the wiring
compartment.
Back box is provided with 11/4" vertical
through feed hubs.

Special polarity where two or more


receptacles of the same ampere rating
and number of poles are to be installed
in the same area for use on different
voltages, alternate polarizations can be
furnished. Details on request.

Dust-Ignitionproof
Raintight
Wet Locations

Standard Finishes:
Feraloy iron alloy electrogalvanized
and aluminum acrylic paint
Copper-free aluminum natural
Phenolic natural (black)
Brass silver plated

Electrical Rating Ranges:


30 and 60 amperes, 480VAC

Grounding:
SRD receptacles and SP plugs are
provided with an extra grounding pole.
In plugs, provision is made for
attachment of a grounding wire to the
grounding pole. In addition, direct
connection is provided between plug
and receptacle housings and the
grounding pole. In the receptacle,
grounding is accomplished through the
conduit system.
CAUTION: To reduce the risk of ignition of hazardous
atmospheres, do not use plugs or receptacles in Class II,
Group F locations that contain electrically conductive
dusts.

Dimensions
In Inches:

Certifications and
Compliances:
NEC:
Class I, Division 1 and 2, Group D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 7D, 9FG, 12
ANSI/UL Standard: 1010

1310

www.crouse-hinds.com

US: 1-866-764-5454

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

SRD Dead Front Interlocked


Receptacles with Factory
Sealed Switch
SP Plugs, 480 VAC, 60400 hertz

SRD Receptacle with spring


door

Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 and 2, Group D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA 3, 7D, 9FG, 12
Explosionproof

SP Plug

SRD Receptacle with threaded


cap

4P

SP Plug with fastening ring

Back Box 11/4" Vertical Through Feed Hubs

Rating

30 amp.

60 amp.

Description

With
Spring
Door
Cat. #

With
Threaded
Cap
Cat. #

With Cable Grip and


Neoprene Bushing
Cable Dia.
Cat. #

2-wire,
3-pole

SRD3324N

3-wire,
4-pole

SRD3424D

4-wire,
5-pole

SRD3524 NW

2-wire,
3-pole

SRD6324N

3-wire,
4-pole

SRD6424D

4-wire,
5-pole

SRD6524 NW

to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to 1.375
[ .875
1.375 to 1.875

With Cable Grip and


Neoprene Bushing
Cable Dia.
Cat. #

SP3363N
SP3365N

SRD3384N

SP3463D
SP3465D

SRD3484D

SP3563 NW
SP3565 NW

SRD3584 NW

SP6363N
SP6365N

SRD6384N

SP6463D
SP6465D

SRD6484D

SP6565 NW
SP6567 NW

SRD6584 NW

to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to .875
[ .500
.875 to 1.375
to 1.375
[ .875
1.375 to 1.875

SP3383N
SP3385N
SP3483D
SP3485D
SP3583 NW
SP3585 NW
SP6383N
SP6385N
SP6483D
SP6485D
SP6585 NW
SP6587 NW

4P

CHS Controls AB

Florettgatan 33
SE-254 67 Helsingborg, Sweden
Tel +46 42 38 61 00, Fax +46 42 38 61 29
chs@chscontrols.se
www.chscontrols.se

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1311

4P

EPC Circuit Breakers and


Enclosures with Interlocked
Arktite Receptacles
APJ/NPJ and DP Arktite Plugs

Applications:

Standard Materials:

The EPC interlock receptacle is


designed for use as a service outlet for
portable equipment
It is designed for use in damp, wet and
corrosive locations, indoors or outdoors,
in areas which are hazardous due to
flammable vapors, gases or combustible
dust. For example: refineries, chemical
plants, and other processing and
handling facilities of a hazardous nature

Bodies, covers and receptacle housings


copper-free aluminum
Operating handles copper-free
aluminum
Operating shafts stainless steel
Interior parts sheet steel
Insulation (receptacles and plugs)
fiberglass-reinforced polyester
Pressure contacts brass
Crimp/solder contacts leaded red
brass

Features:

4P

Cl. I, Div. 1 and 2, Groups C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7CD, 9FG, 12
Explosionproof

Dust-Ignitionproof
Raintight
Wet Locations

Mechanical interlock mechanism for


dead front construction
Receptacles are mechanically
interlocked with circuit breakers to
provide disconnect means, short circuit
protection and thermal time delay
overload protection
A spring door receptacle, located at
bottom of 30, 60 and 100 ampere units
and at front of 200 ampere units, is
mechanically interlocked with the circuit
breaker operating mechanism for
maximum safety
Plug and receptacle contacts cannot be
made or broken under load. The circuit
breaker cannot be closed until the plug
is fully inserted and the plug cannot be
withdrawn unless the breaker is open
Operating handles can be padlocked in
either "ON" or "OFF" positions. Breakers
are trip-free of the handles and will open
under short circuit or overload even if
the handle is locked in the "ON" position
Quick installation and leveling is
provided by the three-point mounting
arrangement which has one keyhole slot
at top and two open slots at bottom
Bodies have four taper-tapped conduit
hubs with integral bushings. Two are
located at top and two directly below.
Sizes are as shown in the listings.

Standard Finishes:

Certifications and
Compliances:

The following special options are available by adding suffix to Cat. #:


Description
Suffix
Special polarity used where two or more receptacles of the same ampere rating,
style and number of poles are to be installed in the same area for use on different
voltages. Available on 30, 60 and 100 ampere units as follows:
Receptacle interior rotated 221/2 clockwise when viewed from face of receptacle
and plug changed to match........................................................................................... S4
Side bosses drilled and tapped same size as standard hubs, 30, 60 and
100 ampere units only ................................................................................................... S366
Back boss drilled and tapped same size as standard hubs, 30, 60 and
100 ampere units only ................................................................................................... S367
Breather and drain (Class I, Class II) ............................................................................. S198V
Breather and drain (Class I only).................................................................................... S454V

NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 7CD, 9FG, 12
ANSI/UL Standard: 1010
CEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Group G
Class III
Encl. 3, 4

Copper-free aluminum natural


Stainless steel natural
Sheet steel electrogalvanized with
chromate finish
Brass natural
Fiberglass-reinforced polyester natural
(red)
Leaded red brass electro-tin-plate

30, 60 and 100 ampere size EPC

Electrical Rating Ranges:


Receptacle ratings: 30, 60, 100 and 200
amperes
Circuit breakers: 100 and 225 ampere
frame sizes

Grounding:
EPC interlocked receptacles and
matching plugs are provided with an
extra grounding pole for attaching a
grounding wire. In addition, direct
connection is provided between plug
and receptacle and the grounding pole.
If a separate grounding wire is not
installed in the enclosure, grounding is
accomplished through the conduit
system.

200 ampere size EPC

Options:

CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F
locations that contain electrically conductive dusts.
Pressure connectors are standard. Crimp/solder type terminators are optionally available for 2, 3 and 4-pole 30 ampere,
3 and 4-pole 60 and 100 ampere. For details, see page 1233. To specify, add the suffix "T" to the catalog number.
For example: APJ3365-T (Plug).

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

1312

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

EPC Circuit Breakers and


Enclosures with Interlocked
Arktite Receptacles

Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 and 2, Groups C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7CD, 9FG, 12
Explosionproof

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

Interchangeability of Plugs with Other


Hazardous and Non-hazardous Location
Receptacles:
Plugs listed for use with 30, 60 and 100 ampere EPC assemblies
are standard Arktite APJ/NPJ plugs. Other standard APJ and CPH
plugs of the same rating, style and number of poles may be used
with EPC receptacles, as well as with DBR, EBBR and EPCB
receptacles listed elsewhere in this section.

4P

As a result, portable equipment suitable for the location and


equipped with the proper plug can be used with AR/NR series
receptacles for non-hazardous locations: EBBR, EPC and EPCB
receptacles for Class I hazardous locations; DR and DBR
receptacles for Class II hazardous locations.

Ordering Information:
100 Ampere Frame Size Thermal-magnetic Circuit Breaker with Non-interchangeable Thermal Trip and
Non-adjustable Magnetic Trip
Circuit Breaker

Enclosure
With Circuit Breaker

Receptacle
with Spring
Door Housing

Rating

30 amp.
2-wire,
3-pole,
Style 2
30 amp.
3-wire,
4-pole,
Style 2

2-pole,
480VAC
or
250 VDC
3-pole,
480VAC
or
250 VDC

60 amp.
2-wire,
3 pole,
Style 2

2-pole,
480VAC
or
250 VDC

60 amp.
3-wire,
4-pole,
Style 2

3-pole,
480VAC
or
250 VDC

100 amp.
2-wire,
3-pole,
Style 2
100 amp.
3-wire,
4-pole,
Style 2

2-pole,
480VAC
or
250 VDC
3-pole,
480VAC
or
250VDC

Hub
Size
(In.)

Ckt.
Bkr.
Amps

600VAC

1 /4

20
30
40*
50*

600VAC

11/4

20
30
40*
50*
50
60
70*
90*
100*

11/4
600VAC
2

50
60
70*
90*
100*

11/4
600VAC
2

600VAC

600VAC

60
70
90
100

60
70
90
100

Without
Circuit
Breaker
Cat. #

Cutler-Hammer
"EHD" Cat. #

General Electric
"TED" Cat. #

EPC43032

EPC43032
EPC43032
EPC43032
EPC43032

WT20
WT30
WT40
WT50

2
2
2
2

EPC43032
EPC43032
EPC43032
EPC43032

TT20
TT30
TT40
TT50

2
2
2
2

EPC43042

EPC43042
EPC43042
EPC43042
EPC43042

WT20
WT30
WT40
WT50

3
3
3
3

EPC43042
EPC43042
EPC43042
EPC43042

TT20
TT30
TT40
TT50

3
3
3
3

EPC46032
EPC66032
EPC66032
EPC66032
EPC66032

WT50 2
WT60 2
WT70 2
WT90 2
WT100 2

EPC46032
EPC66032
EPC66032
EPC66032
EPC66032

TT50 2
TT60 2
TT70 2
TT90 2
TT100 2

EPC46042
EPC66042
EPC66042
EPC66042
EPC66042

WT50 3
WT60 3
WT70 3
WT90 3
WT100 3

EPC46042
EPC66042
EPC66042
EPC66042
EPC66042

TT50 3
TT60 3
TT70 3
TT90 3
TT100 3

EPC61032

EPC61032
EPC61032
EPC61032
EPC61032

WT60 2
WT70 2
WT90 2
WT100 2

EPC61032
EPC61032
EPC61032
EPC61032

TT60 2
TT70 2
TT90 2
TT100 2

EPC61042

EPC61042
EPC61042
EPC61042
EPC61042

WT60 3
WT70 3
WT90 3
WT100 3

EPC61042
EPC61042
EPC61042
EPC61042

TT60 3
TT70 3
TT90 3
TT100 3

EPC46032
EPC66032
EPC46042
EPC66042

225 Ampere Frame Size Circuit Breaker with Interchangeable Thermal Magnetic Trip
Circuit Breaker

Enclosure

Receptacle
with Spring
Door Housing

Rating

Hub
Size
(In.)

200 amp.
3-wire,
4-pole,
Style 2

3-pole,
600VAC
or
250 VDC

With Circuit Breaker

125
150
175
200
225*

Without Circuit
Breaker Cat. #
EPC604 2042
EPC605 2042

*Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only,
as higher trip rating may not protect wiring.
200 ampere units are suitable for Class I, Group D (NEMA 7D).
Enclosures with 600 volt circuit breakers from U.S.A. are available. Information on request.
CSA Certified units are supplied with 600VAC FDB frame circuit breakers.

www.crouse-hinds.com

US: 1-866-764-5454

Cutler-Hammer
"KB" Cat. #
EPC604
EPC604
EPC604
EPC604
EPC604

2042
2042
2042
2042
2042

General Electric
"TFK" Cat. #

WT125
WT150
WT175
WT200
WT225

3
3
3
3
3

EPC605
EPC605
EPC605
EPC605
EPC605

2042
2042
2042
2042
2042

TT125
TT150
TT175
TT200
TT225

4P

Ckt.
Bkr.
Amps

3
3
3
3
3

CAUTION: To reduce the risk of ignition of hazardous


atmospheres, do not use plugs or receptacles in Class II, Group
F locations that contain electrically conductive dusts.

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1313

4P

APJ Plug

Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 and 2, Groups C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7CD, 9FG, 12
Explosionproof

APJ/NPJ and DP Arktite


Plugs with Cable Grip and
Neoprene Bushing

NPJ Plug

DP Plug

Ordering Information - APJ/NPJ and DP Arktite Plugs


600VAC/250VDC with Cable Grip and Neoprene Bushing Style 2
Cable
O.D. Range

2-wire, 3-pole
Cat. #

3-wire, 4-pole
Cat. #

30

0.60 to 1.20
0.55 to 0.70
0.70 to 0.85

APJ3385
NPJ3383
NPJ3384

APJ3485
NPJ3483
NPJ3484

60

0.75 to 1.45
0.75 to 1.07
1.07 to 1.35

APJ6385
NPJ6384
NPJ6385

APJ6485
NPJ6484
NPJ6485

100

1.00 to 1.70
0.93 to 1.21
1.21 to 1.50

APJ10387
NPJ10386
NPJ10387

APJ10487
NPJ10486
NPJ10487

Amps

200

1.875 to 2.50

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

Pressure connectors are supplied as standard. To


specify crimp/solder type terminations add the suffix "T"
to the catalog number. For example: APJ3385-T (Plug).

DP20468

Dimensions

4P

In Inches:

APJ

Recept.
30 Amp.
60 Amp.
60 Amp.
100 Amp.
200 Amp.

NPJ

Breaker

hh

2050 Amp.
50 Amp.
70100 Amp.
70100 Amp.
125225 Amp.

24
241/2
241/2
251/4
36

105/8
105/8
1213/16
1213/16
18

143/8
143/8
143/8
143/8
27

93/8
93/8
93/8
93/8

711/16
711/16
711/16
711/16
131/2

113/4
113/4
113/4
113/4

49/16
51/16
51/16
513/16

413/16
513/16
513/16
65/8

7
613/16
613/16
73/4

203/4
203/4
203/4
203/4
341/4

73/8
73/8
91/4
91/4

21/16
21/16
25/8
25/8

Dim. "h" and "hh" are exposed portion of plug when engaged with receptacle.

1314

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

51/2

EPCB Circuit Breakers and


Enclosures with Interlocked
Arktite Receptacles
APJ/NPJ Arktite Plugs

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7BCD, 9FG, 12
Explosionproof

Applications:

Standard Materials:

The EPCB interlock receptacle is designed


for use as a service outlet for portable
equipment. The circuit breaker provides
overcurrent and short circuit protection
It has a mechanical interlock mechanism
for dead front construction and no load
make or break feature
It is designed for use in damp, wet and
corrosive locations, indoors or outdoors,
in areas which are hazardous due to
flammable vapors, gases or combustible
dust. For example: refineries, chemical
plants, and other processing and
handling facilities of a hazardous nature

Bodies, covers and receptacle housings


copper-free aluminum
Operating handles copper-free aluminum
Operating shafts stainless steel
Interior parts sheet steel
Insulation fiberglass-reinforced polyester
Pressure contacts brass
Crimp/solder contacts leaded red brass

Features:
Spring door receptacle located at the
bottom is mechanically interlocked with
the circuit breaker operating mechanism
for maximum safety. Plug and receptacle
contacts cannot be made or broken
under load. The circuit breaker cannot
be closed until the plug is fully inserted
and the plug cannot be withdrawn
unless the breaker is open
Operating handles can be padlocked in
either "ON" or "OFF" positions. Breakers
are trip-free of the handles and will open
under short circuit or overload even if
the handle is locked in the "ON" position
Quick installation and leveling is
provided by the three-point mounting
arrangement having one keyhole slot at
top and two open slots at bottom
Bodies have four 11/4" taper tapped
conduit hubs with integral bushings. Two
are located at top and two directly below
When installing, seals suitable for
Class I, Group B hazardous areas
must be located within 11/2" of each
conduit opening

Certifications and
Compliances:

4P

Standard Finishes:
Copper-free aluminum natural
Stainless steel natural
Sheet steel zinc electroplate with
chromate finish
Brass natural
Fiberglass-reinforced polyester
natural (red)
Leaded red brass electro-tin-plate

Electrical Rating Ranges:


Receptacle ratings: 30, 60 and 100
amperes
Circuit breakers: 100 ampere frame size

Options:
The following special options are available by adding the suffix to the Cat. #:
Description
Suffix
Special polarity. For use where two or more receptacles of the same ampere rating,
style and number of poles are to be installed in the same area for use on different
voltages. Receptacle interior rotated 221/ 2 to right (viewed from face) and plug
changed to match ......................................................................................................... S4
Side bosses drilled and tapped same size as standard hubs ...................................... S366
Back boss drilled and tapped same size as standard hubs......................................... S367

Interchangeability of Plugs
with Other Hazardous and
Non-hazardous Location
Receptacles:
Plugs listed for use with EPCB
assemblies are standard Arktite APJ/NPJ
plugs. Other standard APJ and CPH
plugs of the same rating, style and
number of poles may be used with
EPCB receptacles as well as DBR and
EPC receptacles listed elsewhere in this
section
As a result, portable equipment suitable
for the location and equipped with the
proper plug can be used with AR/NR
series receptacles for non-hazardous
locations; EBBR, EPC and EPCB
receptacles for Class I hazardous
locations; DR and DBR receptacles for
Class II hazardous locations

Grounding:
EPCB interlocked receptacles and
matching plugs are provided with an
extra grounding pole for attaching a
grounding wire. In addition, direct
connection is provided between plug
and receptacle and the grounding pole.
If a separate grounding wire is not
installed in the enclosure, grounding is
accomplished through the conduit
system

4P

NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 7BCD, 9FG, 12
ANSI/UL Standard: 1010
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Group G
Class III
Encl. 3, 4

Dust-Ignitionproof
Raintight
Wet Locations

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

Pressure connectors are supplied as standard. To specify crimp/solder type terminations add the suffix "T" to the catalog number. For example: APJ3365-T (Plug).

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1315

4P

Cl. I, Div. 1 and 2, Groups B, C, D


Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7BCD, 9FG, 12
Explosionproof

EPCB Circuit Breakers and


Enclosures with Interlocked
Arktite Receptacles
APJ/NPJ Arktite Plugs

Dust-Ignitionproof
Raintight
Wet Locations

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

Ordering Information:
100 Ampere Frame Size Thermal-magnetic Circuit Breaker with
Non-interchangeable Thermal Trip and Non-adjustable Magnetic Trip
Circuit Breaker
Receptacle
with Spring
Door Housing Rating
30 amp.
2-wire,
3-pole,
Style 2
30 amp.
3-wire,
4-pole,
Style 2

2-pole,
600VAC
or
250 VDC
3-pole,
600VAC
or
250 VDC

60 amp.
2-wire,
3-pole,
Style 2

2-pole,
600VAC
or
250 VDC

60 amp.
3-wire,
4-pole,
Style 2

3-pole,
600VAC
or
250 VDC

100 amp.
2-wire,
3-pole,
Style 2
100 amp.
3-wire,
4-pole,
Style 2

2-pole,
600VAC
or
250 VDC
3-pole,
600VAC
or
250 VDC

Enclosure with Circuit Breaker


Hub Ckt.
Size Bkr.
(In.)
Amps Cutler-Hammer

General Electric

1 /4

20
30
40*
50*

EPCB43632
EPCB43632
EPCB43632
EPCB43632

WT20HFD
WT30HFD
WT40HFD
WT50HFD

2
2
2
2

EPCB43632
EPCB43632
EPCB43632
EPCB43632

TT20TED
TT30TED
TT40TED
TT50TED

2
2
2
2

1 /4

20
30
40*
50*

EPCB43642
EPCB43642
EPCB43642
EPCB43642

WT20HFD 3
WT30HFD3
WT40HFD 3
WT50HFD 3

EPCB43642
EPCB43642
EPCB43642
EPCB43642

TT20TED
TT30TED
TT40TED
TT50TED

3
3
3
3

11/4

50
60*
70*
90*
100*

EPCB46632
EPCB46632
EPCB46632
EPCB46632
EPCB46632

WT50HFD 2
WT60HFD 2
WT70HFD 2
WT90HFD 2
WT100HFD 2

EPCB46632
EPCB46632
EPCB46632
EPCB46632
EPCB46632

TT50TED 2
TT60TED 2
TT70TED 2
TT90TED 2
TT100TED 2

11/4

50
60*
70*
90*
100*

EPCB46642
EPCB46642
EPCB46642
EPCB46642
EPCB46642

WT50HFD 3
WT60HFD 3
WT70HFD 3
WT90HFD 3
WT100HFD 3

EPCB46642
EPCB46642
EPCB46642
EPCB46642
EPCB46642

TT50TED 3
TT60TED 3
TT70TED 3
TT90TED 3
TT100TED 3

11/4

70
90
100

EPCB41632 WT70HFD 2
EPCB41632 TT70TED 2
EPCB41632 WT90HFD 2
EPCB41632 TT90TED 2
EPCB41632 WT100HFD 2 EPCB41632 TT100TED 2

1 /4

70
90
100

EPCB41642 WT70HFD 3
EPCB41642 TT70TED 3
EPCB41642 WT90HFD 3
EPCB41642 TT90TED 3
EPCB41642 WT100HFD 3 EPCB41642 TT100TED 3

Pressure connectors are supplied as standard.


To specify crimp/solder type terminators add the
suffix "T" to the catalog number. For example:
APJ3385-T (Plug).
*Circuit breaker trip rating may exceed receptacle
rating for welding equipment applications only, as
higher trip rating may not protect wiring.
For detailed information on circuit breaker
selection see Section 3C.

APJ/NPJ Arktite Plugs


600VAC/250VDC with Cable Grip and Neoprene
Bushing Style 2
APJ Plug

Cable
O.D. Range

2-wire,
3-pole
Cat. #

3-wire,
4-pole
Cat. #

30

0.60 to 1.20
0.55 to 0.70
0.70 to 0.85

APJ3385
NPJ3383
NPJ3384

APJ3485
NPJ3483
NPJ3484

60

0.75 to 1.45
0.75 to 1.07
1.07 to 1.35

APJ6385
NPJ6384
NPJ6385

APJ6485
NPJ6484
NPJ6485

100

1.00 to 1.70
0.93 to 1.21
1.21 to 1.50

APJ10387
NPJ10386
NPJ10387

APJ10487
NPJ10486
NPJ10487

NPJ Plug
Amps

Dimensions

4P

In Inches:

APJ

NPJ

Receptacle
30 Amp.
60 Amp.
100 Amp.

261/ 4
263/ 4
271/ 2

115/ 16
115/ 16
115/ 16

113/ 4
113/ 4
113/ 4

85/ 8
85/ 8
85/ 8

5
5
5

73/ 4
73/ 4
73/ 4

Receptacle
30 Amp.
60 Amp.
100 Amp.

jj

139/ 16
139/ 16
139/ 16

415/ 16
57/ 16
63/ 16

413/ 16
513/ 16
65/ 8

7
613/ 16
73/ 4

243/ 4
243/ 4
243/ 4

83/ 16
83/ 16
83/ 16

15/ 8
15/ 8
15/ 8

Dim "j" and "jj" are exposed portion of plug when engaged with receptacle.

1316

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

Cl. II, Div. 1 and 2, Groups F, G


Cl. III
NEMA/EEMAC 3, 9FG, 12
Dust-Ignitionproof
Raintight

DBR Interlocked Arktite


Receptacles With Enclosed
Circuit Breakers
APJ/NPJ Arktite Plugs
Applications:

Standard Finishes:

DBR interlocked Arktite receptacles with


enclosed circuit breakers and APJ/NPJ
Arktite plugs are used:
To supply power to portable electrical
equipment such as motor-generator
sets, compressors, heating and cooling
units, conveyors, and similar equipment
In locations where hazardous dusts are
present, as in grain processing and
handling plants, chemical plants and
certain food processing industries
Indoors or outdoors in damp, wet or
corrosive locations

Copper-free aluminum plug exterior,


enclosure and receptacle housing
natural
Stainless steel natural
Brass natural
Fiberglass-reinforced polyester
natural (red)
Leaded red brass electro-tin-plate

Features:
Receptacles are mechanically interlocked
with circuit breakers to provide
disconnect means, short circuit
protection and thermal time delay
overload protection.
Enclosures are compact and rectangular
in shape permitting close spacing.
For maximum safety, the spring door
receptacle at the bottom is mechanically
interlocked with the circuit breaker
operating mechanism. The circuit
breaker cannot be closed until the plug
is fully inserted and the plug cannot be
withdrawn unless the breaker is open.
Operating handles can be padlocked in
either "ON" or "OFF" positions. Breakers
are trip-free of the handles and will open
under short circuit or overload even if the
handle is locked in the "ON" position.
Enclosure is provided with a drilled and
tapped conduit opening at top center,
equipped with a threaded-in bushing. The
size furnished is 11/2", and removing the
bushing permits the use of a 2" conduit.

Certifications and
Compliances:
NEC:
Class II, Division 1 and 2, Groups F, G
Class III
NEMA/EEMAC: 3, 9FG, 12
UL Standard: 698, 1010
CEC:
Class II, Division 1 and 2, Group G
Class III
Encl. 3, 5

Bodies, covers and operating handles


copper-free aluminum
Operating shafts stainless steel
Receptacle housings and plug exteriors
copper-free aluminum
Insulation: plugs and receptacles
fiberglass-reinforced polyester
Pressure contacts brass
Crimp/solder contacts leaded red brass

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

Options:
The following special options are available
by adding suffix to Cat. #:
Description
Suffix
Special polarity for use where
two or more receptacles of the
same ampere rating, style and
number of poles are to be
installed in the same area for use
on different voltages. Receptacle
interior rotated 221/ 2 clockwise
when viewed from receptacle face
and plug changed to match .......... S4
Breather (drain furnished as
standard)........................................ S219
Conduit arrangements other than
standard can be supplied. Details
on request.

CAUTION: To reduce the risk of ignition of hazardous


atmospheres, do not use plugs or receptacles in
Class II, Group F locations that contain electrically
conductive dusts.

Electrical Rating Ranges:


Receptacle ratings: 30, 60 and
100 amperes
Circuit breakers: 100 ampere frame size

Dimensions
In Inches:

Interchangeability of Plugs
with Other Hazardous and
Non-hazardous Location
Receptacles:
Plugs listed for use with DBR assemblies
are standard Arktite APJ/NPJ plugs.
Other standard APJ/NPJ and CPH plugs
of the same rating, style and number of
poles may be used with DBR
receptacles, as well as with EBBR,
EPC and EPCB receptacles listed in
Section 4P.
As a result, portable equipment suitable
for the locations and equipped with the
proper plug can be used with AR
receptacles for non-hazardous locations,
with EBBR, EPC and EPCB receptacles
for Class I hazardous locations, and with
DR and DBR interlocked receptacles for
Class II hazardous locations.

4P

Standard Materials:

4P

Dimensions:
Amps
30
60
100

bb

213/4
223/4
231/2

61/2
81/2
101/8

7
613/16
73/4

APJ

NPJ

Dim. "b" and "bb" are exposed portion of plug when


engaged with receptacle.

www.crouse-hinds.com

Pressure connectors are standard. Crimp/solder type


terminators are optionally available for 3 and 4-pole,
30, 60 and 100 ampere. For details, see page 1233.
To specify, add the suffix "T" to the catalog number.
For example: AP3375-T (Plug).

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds

1317

Cl. II, Div. 1 and 2, Groups F, G


Cl. III
NEMA/EEMAC 3, 9FG, 12
Dust-Ignitionproof
Raintight

DBR Interlocked Arktite


Receptacles With Enclosed
Circuit Breakers

4P

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29


chs@chscontrols.se www.chscontrols.se

Ordering Information:
100 Ampere Frame Size with Non-interchangeable Thermal Trip
and Non-adjustable Magnetic Trip
Enclosure
Receptacle
With Spring
Door Housing
30 amp.,
3-wire,
3-pole,
Style 1
30 amp.,
2-wire,
3-pole,
Style 2
30 amp.,
3-wire,
4-pole,
Style 2

Circuit
Breaker
Rating

Hub
Size
(In.)

Ckt.
Bkr.
Amps

1 /2

20
30
40
50

DBR53731

3-pole
600VAC

DBR53731
DBR53731
DBR53731
DBR53731

WT20
WT30
WT40
WT50

3
3
3*
3*

2-pole
600VAC
or
250 VDC

20
30
40
50

DBR53732

11/2

DBR53732
DBR53732
DBR53732
DBR53732

WT20
WT30
WT40
WT50

2
2
2*
2*

11/2

20
30
40
50

DBR53742

3-pole
600VAC

DBR53742
DBR53742
DBR53742
DBR53742

WT20
WT30
WT40
WT50

3
3
3*
3*

DBR56731

11/2

50
60
70
90
100

DBR56731
DBR56731
DBR56731
DBR56731
DBR56731

WT50 3
WT60 3
WT70 3*
WT90 3*
WT100 3*

DBR56732

11/2

50
60
70
90
100

DBR56732
DBR56732
DBR56732
DBR56732
DBR56732

WT50 2
WT60 2
WT70 2*
WT90 2*
WT100 2*

DBR56742

3-pole
600VAC

11/2

50
60
70
90
100

DBR56742
DBR56742
DBR56742
DBR56742
DBR56742

WT50 3
WT60 3
WT70 3*
WT90 3*
WT100 3*

1 /2

60
70
90
100

DBR51731

3-pole
600VAC

DBR51731
DBR51731
DBR51731
DBR51731

WT60 3
WT70 3
WT90 3
WT100 3

2-pole
600VAC
or
250 VDC

60
70
90
100

DBR51732

11/2

DBR51732
DBR51732
DBR51732
DBR51732

WT60 2
WT70 2
WT90 2
WT100 2

11/2

60
70
90
100

DBR51742

3-pole
600VAC

DBR51742
DBR51742
DBR51742
DBR51742

WT60 3
WT70 3
WT90 3
WT100 3

60 amp.,
3-wire,
3-pole,
Style 1

3-pole
600VAC

60 amp.,
2-wire,
3-pole,
Style 2

2-pole
600VAC
or
250 VDC

60 amp.,
3-wire,
4-pole,
Style 2
100 amp.,
3-wire,
3-pole,
Style 1
100 amp.,
2-wire,
3-pole,
Style 2
100 amp.,
3-wire,
4-pole,
Style 2

Without Circuit
Breaker Cat. #

APJ/NPJ Arktite Plugs

Amps

4P

APJ Plug

1318

www.crouse-hinds.com

With Circuit
Breaker Cat. #
Cutler-Hammer "FDB"

Cable
O.D. Range

*Circuit breaker trip rating may exceed receptacled


rating for welding equipment applications only, as
higher trip rating may not protect wiring.
For detailed information on circuit breaker selection,
see Section 3C.
Style 1 Grounded through shell. Style 2 Grounded
through extra pole and shell. For a detailed description
of these grounding methods, see page 1231.

Style 1
3-wire,
3-pole
Cat. #

Style 2
2-wire,
3-pole
Cat. #

3-wire,
4-pole
Cat. #

0.60 to 1.20
0.55 to 0.70
0.70 to 0.85

APJ3375

30

APJ3385
NPJ3383
NPJ3384

APJ3485
NPJ3483
NPJ3484

0.75 to 1.45
0.75 to 1.07
1.07 to 1.35

APJ6375

60

APJ6385
NPJ6384
NPJ6385

APJ6485
NPJ6484
NPJ6485

1.00 to 1.70
0.93 to 1.21
1.21 to 1.50

APJ10377

100

APJ10387
NPJ10386
NPJ10387

APJ10487
NPJ10486
NPJ10487

NPJ Plug

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2010 Cooper Crouse-Hinds