Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
HIDRULICA II Y LABORATORIO
INFORMES DE LABORATORIO
PRESENTADO POR:
KELLY A RODRIGUEZ COD 7300113
BOGOTA, F E B R E R O 2013
TABLA DE CONTENIDO
1.
LABORATORIO FLUJO UNIFORME ........................................................................................ 6
INTRODUCCIN .................................................................................................................................. 6
MARCO TERICO ............................................................................................................................... 7
DIAGRAMA DE FLUJO FLUJO UNIFORME .......................................................................................... 8
DESARROLLO DE LABORATORIO FLUJO UNIFORME....................................................................... 9
DATOS DE LABORATORIO ......................................................................................................................... 9
1.1.1 Pendiente inicial ....................................................................................................................... 9
1.1.2 Caudales ................................................................................................................................ 10
1.1.3 Profundidad normal observada ............................................................................................... 11
1.1.4 Coeficiente de rugosidad de Manning "n"................................................................................ 14
1.1.5 Coeficiente de resistencia de Chezy "C" ................................................................................. 15
1.1.6 Nmero de Froude Fr ............................................................................................................. 15
1.1.7 Profundidad crtica yc ............................................................................................................. 15
RESULTADOS DE LOS ENSAYOS .............................................................................................................. 16
1.1.8 Condiciones de flujo ............................................................................................................... 19
ANALISIS DE RESULTADOS FLUJO UNIFORME .............................................................................. 20
CONCLUSIONES FLUJO UNIFORME ................................................................................................ 21
2.
LABORATORIO FLUJO GRADUALMENTE VARIADO............................................................ 22
INTRODUCCIN ................................................................................................................................ 22
DIAGRAMA DE FLUJO GRADUALMENTE VARIADO ......................................................................... 23
DESARROLLO DE LABORATORIO FLUJO GRADUALMENTE VARIADO .......................................... 24
DATOS DE LABORATORIO ....................................................................................................................... 24
RESULTADOS DE LOS ENSAYOS .............................................................................................................. 29
PERFILES OBTENIDOS ........................................................................................................................... 33
ANALISIS DE RESULTADOS FLUJO GRADUALMENTE VARIADO ................................................... 39
CONCLUSIONES FLUJO GRADUALMENTE VARIADO ..................................................................... 40
3.
LABORATORIO CHIMENA DE EQUILIBRIO .......................................................................... 41
INTRODUCCIN ................................................................................................................................ 41
MARCO TERICO ............................................................................................................................. 42
DIAGRAMA DE FLUJO CHIMENA DE EQUILIBRIO ............................................................................ 43
DESARROLLO DE LABORATORIO FLUJO GRADUALMENTE VARIADO .......................................... 44
DATOS DE LABORATORIO ....................................................................................................................... 44
3.1.1 Calculo de Coeficiente Friccin K1 ......................................................................................... 44
3.1.2 Calculo Zmax ......................................................................................................................... 45
3.1.3 Graficas F(z) vs z .................................................................................................................... 46
ANALISIS DE RESULTADOS DE CHIMENEA DE EQUILIBRIO .......................................................... 48
CONCLUSIONES FLUJO CHIMENEA DE EQUILIBRIO ...................................................................... 49
4.
LABORATORIO COMPUERTAS ............................................................................................ 50
INTRODUCCIN ................................................................................................................................ 50
MARCO TERICO ............................................................................................................................. 51
DIAGRAMA DE FLUJO CHIMENA DE EQUILIBRIO ............................................................................ 52
DESARROLLO DE LABORATORIO FLUJO GRADUALMENTE VARIADO .......................................... 53
DATOS DE LABORATORIO ....................................................................................................................... 53
4.1.1 Calculo de coeficientes de descarga Cd ................................................................................. 54
4.1.2 Calculo de coeficientes de descarga Cc ................................................................................. 54
ANALISIS DE RESULTADOS DE COMPUERTAS .............................................................................. 58
CONCLUSIONES FLUJO COMPUERTAS .......................................................................................... 59
5.
LABORATORIO RESALTO HIDRAULICO .............................................................................. 60
INTRODUCCIN ................................................................................................................................ 60
MARCO TERICO ............................................................................................................................. 61
DIAGRAMA DE FLUJO FLUJO GRADUALMENTE VARIADO ............................................................. 62
DESARROLLO DE LABORATORIO FLUJO GRADUALMENTE VARIADO .......................................... 63
DATOS DE LABORATORIO ....................................................................................................................... 63
5.1.1 CALCULOS ............................................................................................................................ 63
5.1.2 Clculos de Y2 TERICO. ..................................................................................................... 64
5.1.3 Lnea Piezometrica ................................................................................................................. 64
5.1.4. Medida de Profundidades Y1 y Y2 .......................................................................................... 66
5.1.5. Calculo de La perdida de Energia ........................................................................................... 68
5.1.6. Decir por qu la fuerza especfica ........................................................................................... 70
ANALISIS DE RESULTADOS DE RESALTO HIDRAULICO .................................................................................. 71
CONCLUSIONES RESALTO HIDRAULICO ..................................................................................................... 72
6.
LABORATORIO DE VERTEDEROS .................................................................................................. 73
INTRODUCCIN .................................................................................................................................... 73
MARCO TERICO................................................................................................................................... 74
DIAGRAMA DE FLUJO FLUJO GRADUALMENTE VARIADO ............................................................................. 75
DESARROLLO DE LABORATORIO VERTEDEROS ........................................................................................... 76
DATOS DE LABORATORIO ............................................................................................................................. 76
6.1.1 ECUACIONES:....................................................................................................................... 77
ANALISIS DE RESULTADOS DE RESALTO HIDRAULICO .................................................................................. 78
CONCLUSIONES VERTEDEROS ................................................................................................................. 79
GLOSARIO ............................................................................................................................................ 80
TABLAS
GRFICAS
Grfica 1.1 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q1............... 12
Grfica 1.2 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q2............... 13
Grfica 1.3 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q3............... 14
Grfica 1.4 comportamiento de las coordenadas de profundidad en funcin de la longitud ............... 16
Grfica 1.5 comportamiento de las coordenadas de profundidad en funcin del la longitud ............... 17
Grfica 1.6 comportamiento de las coordenadas de profundidad en funcin del la longitud ............... 18
Grfica 2.1 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q1............... 26
Grfica 2.2 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q2............... 27
Grfica 2.4 Comportamiento de la profundidad Normal en funcin de la Prpfundidad Critica Q1 ....... 30
Grfica 3.1 Variacin de la altura Z max promedio ............................................................................ 46
Grfica 4.1 Altura de la compuerta a1 ............................................................................................... 55
Grfica 4.2 Altura de la compuerta a2 ............................................................................................... 56
Grfica 4.3 Altura de la compuerta a3 ............................................................................................... 56
Grfica 1.4 Resumen de clculos obtenidos ...................................................................................... 57
Grfica 5.1 Comportamiento de resalto ............................................................................................. 65
Grfica 6.1 Comportamiento de Los vertederos en funcin del Caudal .............................................. 77
Grfica 6.21 Ecuaciones Lineales de Los Vertederos ........................................................................ 77
INTRODUCCIN
El flujo libre se presenta cuando los lquidos fluyen por la accin de la gravedad y solo
estn parcialmente envueltos por un contorno slido.
El conducto por el cual circula agua con flujo libre se llama canal, el que puede ser
cerrado o abierto. Las caractersticas generales del flujo libre son:
Presenta una superficie del lquido en contacto con la atmsfera, llamada superficie
libre.
La superficie libre coincide con la lnea piezomtrica.
Cuando el fluido es agua a temperatura ambiente, el rgimen de flujo es
usualmente turbulento.
OBJETIVO GENERAL
Determinar la informacin obtenida en el laboratorio (condiciones ideales) del flujo
uniforme.
OBJETIVOS ESPECIFICOS.
MARCO TERICO
Cuando el flujo ocurre en un canal abierto, el agua encuentra resistencia a medida que fluye
aguas abajo. Esta resistencia por lo general es contrarrestada por las componentes de las
fuerzas gravitacionales que actan sobre el cuerpo de agua en la direccin del movimiento
Un flujo uniforme se alcanzar si la resistencia se equilibra con las fuerzas gravitacionales.
La profundidad del flujo uniforme se conoce como profundidad normal.
Se considera que el flujo uniforme tiene las siguientes caractersticas principales:
La profundidad, el rea mojada, la velocidad y el caudal en cada seccin del canal
son constantes.
La lnea de energa, la superficie del agua y el fondo del canal son paralelos, es decir,
sus pendientes son todas iguales Sf = Sw = So = S, donde Sf es la pendiente
de la lnea de energa, Sw es la pendiente del agua y So es la pendiente del fondo del
canal.
Coeficiente de Chezy
HIDRAULICA II
Ecuacin de Manning
HIDRAULICA II
Datos de Laboratorio
Tabla.1.1 Parmetros geomtricos del canal
1.1.1
Abscisas
dx 10
dx 10-13
dx 13-16
dx 16-19
dx 19-23
0
91.5
90
99
118
0
91.5
181.5
280.5
398.5
Pendiente inicial
La inclinacin inicial del canal determina la pendiente del mismo a travs del experimento,
de acuerdo a las caractersticas del Flujo Uniforme en el que la pendiente de energa
hidrosttica (piezomtrica) es constante e igual a la pendiente del canal.
HIDRAULICA II
LECTURA INICIAL
Inclinada
Horizontal
Valores
2.17
1.95
2.17
1.94
2.17
1.92
2.17
1.9
2.17
1.87
2.17
1.85
2.17
1.81
2.17
1.78
2.17
1.76
2.17
1.73
2.17
1.7
2.17
1.66
2.17
1.63
2.16
1.58
14.4
PIEZ. No.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Hv
1.1.2
Q1
Q2
hpiez
2.1
2.1
2.08
2.07
2.05
2.03
2
1.98
1.96
1.94
1.9
1.87
1.85
1.8
Y
1.8
1.8
1.8
2
2.1
2.2
2.6
2.6
2.6
2.6
2.6
2.6
2.8
2.8
Q3
hpiez
2.1
2.1
2.08
2.08
2.05
2.04
2.01
2
1.98
1.95
1.9
1.84
1.85
1.82
Y
1.9
1.9
1.9
2
2.1
2.1
2.1
2.3
2.4
2.5
2.5
2.6
2.6
2.6
21.9
hpiez
2.12
2.1
1.99
1.98
1.97
1.95
1.92
1.9
1.88
1.85
1.83
1.8
1.75
1.73
24.9
Y
1.9
2
2
2
2.1
2.2
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.7
25.4
Caudales
DETERMINACIN DE CAUDALES
H = (Hv - H0)
2,34
Q (0,0172H )
HIDRAULICA II
Q0
Q1
Q2
Q3
3.6
11.1
14.1
14.6
UNIDAD
0.3446
lps
4.8038
LPS
8.4082
LPS
9.1225
LPS
344.569076
0.0003
cm3
m3/s
4803.79
0.0048
cm3/s
m3/s
8408.16
0.0084
cm3/s
m3/s
9122.51
0.0091
cm3/s
m3/s
1.1.3
Q1
Intervalos
Altura
de
piezomtrica
profundidad
promedio
y 10
2.10
y 10-13
3.31
y 13-16
3.31
y 16-19
3.31
y 19-23
3.309
PENDIENTE
0.00236
PROMEDIO
3.3087
HIDRAULICA II
Profundidad
promedio
1.80
2.35
2.35
2.35
2.350
ynormal
2.3500
Q1 = 4.8 lps
4.00
3.50
Altura (cm)
3.00
2.50
Altura
piezomtrica
promedio
Profundidad
experimental
2.00
h0
1.50
Altura
piezomtrica
inicial
Lineal (Altura
piezomtrica
promedio)
1.00
0.50
0.00
0
50
100
150
200
250
300
350
400
450
Grfica 1.1 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q1
Q2
Intervalos
Altura
de
piezomtrica
profundidad
promedio
y 10
2.10
y 10-13
3.51
y 13-16
3.51
y 16-19
3.51
y 19-23
3.51
PENDIENTE
0.00276
PROMEDIO
3.5133
HIDRAULICA II
Profundidad
promedio
1.90
1.93
2.10
2.40
2.58
ynormal
2.2769
Q2 = 8.41 lps
4.00
3.50
Altura piezomtrica
promedio
Profundidad
experimental
Altura (cm)
3.00
2.50
Altura piezomtrica
inicial
2.00
Lineal (Altura
piezomtrica promedio)
h0
1.50
Lineal (Altura
piezomtrica inicial)
1.00
0.50
0.00
50
100
150
200
250
300
350
400
450
Q3
Intervalos
Altura
de
piezomtrica
profundidad
promedio
y 10
2.12
y 10-13
2.02
y 13-16
1.95
y 16-19
1.88
y 19-23
1.78
PENDIENTE
-0.00084
PROMEDIO
1.8968
HIDRAULICA II
Profundidad
promedio
1.90
2.00
2.17
2.40
2.63
ynormal
2.3221
Q3 9.12 lps
3.00
h
2.50
Altura piezomtrica
promedio
Profundidad experimental
Altura (cm)
2.00
h0
1.50
0.50
0.00
0
100
200
300
400
500
Grfica 1.3 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q3
1.1.4
Este parmetro del canal se ha calculado para cada caudal a partir de la ecuacin:
HIDRAULICA II
1.1.5
Este parmetro del canal se ha calculado para cada caudal a partir de la ecuacin:
1.1.6
Nmero de Froude Fr
El nmero de Froude define la relacin entre las fuerzas inerciales y la velocidad del flujo,
est determinado por la ecuacin:
1.1.7
Profundidad crtica yc
La profundidad crtica es la altura de la lmina de agua que indica el cambio de flujo entre
supercrtico y subcrtico, es decir, para la cual Fr = 1. Para canales rectangulares:
Q=Q/b
HIDRAULICA II
A(m2)
0.0048
0.0047
0.0048
Q1
Q2
Q3
P(m)
0.2525
0.2510
0.25
R(m)
0.0191
0.0186
0.02
Tabla Error! No hay texto con el estilo especificado en el documento..7 Condiciones ideales
y experimentales de acuerdo al fondo del canal para Q1
CONDICIONES IDEALIZADAS Y EXPERIMENTALES REFERIDAS AL FONDO DEL CANAL
Q1
4.8LPS
Fondo
0.00
91.50
181.50
280.50
398.50
0.00
-0.03
-0.06
-0.09
-0.12
Profundidad Coordenada
experiment profundidad
al
normal
Altura
piezomtrica Videal (cm/s)
promedio
Altura de
velocidad
Altura de
energa
Coordenada
profundidad
crtica
3.82
3.79
3.76
3.73
3.70
1.80
2.32
2.29
2.26
2.23
2.35
2.32
2.29
2.26
2.23
2.10
3.31
3.31
3.31
3.31
99.47
99.47
99.47
99.47
99.47
5.04
5.01
4.99
4.96
4.92
7.39
7.34
7.28
7.22
7.15
yn (cm)
2.35
q (m3/s.m)
0.0234
n
0.0013
C
408.82
yc (cm)
3.82
Fr
2.07
CONDICIONES IDEALES Q1
8.00
6.00
yc
Fondo
cm
4.00
2.00
yn
0.00
0.00
-2.00
-4.00
Coordenada
profundidad normal
Coordenada
profundidad crtica
100.00
200.00
300.00
400.00
500.00
Fondo=S0.x
Longitud (cm)
HIDRAULICA II
Tabla Error! No hay texto con el estilo especificado en el documento..8 Condiciones ideales
y experimentales de acuerdo al fondo del canal para Q2
CONDICIONES IDEALIZADAS Y EXPERIMENTALES REFERIDAS AL FONDO DEL CANAL
Q2
8.41LPS
Fondo
0.00
91.50
181.50
280.50
398.50
0.00
-0.03
-0.06
-0.09
-0.12
Profundidad Coordenada
experiment profundidad
al
normal
Altura
piezomtrica Videal (cm/s)
promedio
Altura de
velocidad
Altura de
energa
Coordenada
profundidad
crtica
5.55
5.52
5.49
5.46
5.42
1.90
1.91
2.04
2.31
2.45
2.28
2.25
2.22
2.19
2.15
2.10
3.51
3.51
3.51
3.51
179.70
179.70
179.70
179.70
179.70
16.46
16.43
16.40
16.37
16.34
18.74
18.68
18.62
18.56
18.49
yn (cm)
2.28
q (m3/s.m)
0.04
n
0.0007
C
748.12
yc (cm)
5.55
Fr
3.80
CONDICIONES IDEALES Q2
8.00
Fondo
6.00
yc
Profundidad experimental
4.00
cm
yn
2.00
y
Fondo=S0.x
0.00
0.00
50.00
100.00
150.00
200.00
250.00
300.00
350.00
400.00
450.00
-2.00
-4.00
Longitud (cm)
HIDRAULICA II
Tabla 1.9 Condiciones ideales y experimentales de acuerdo al fondo del canal para Q3
CONDICIONES IDEALIZADAS Y EXPERIMENTALES REFERIDAS AL FONDO DEL CANAL
Q3
9.12LPS
Fondo
0.00
91.50
181.50
280.50
398.50
0.00
-0.03
-0.06
-0.09
-0.12
Profundidad Coordenada
experiment profundidad
al
normal
Altura
piezomtrica Videal (cm/s)
promedio
Altura de
velocidad
Altura de
energa
Coordenada
profundidad
crtica
5.86
5.83
5.80
5.77
5.73
1.90
1.97
2.11
2.31
2.50
2.32
2.29
2.27
2.24
2.20
2.12
2.02
1.95
1.88
1.78
191.17
191.17
191.17
191.17
191.17
18.63
18.60
18.57
18.54
18.50
20.95
20.89
20.84
20.78
20.70
yn (cm)
2.32
q (m3/s.m)
0.04
n
0.0007
C
789.53
yc (cm)
5.86
Fr
4.01
CONDICIONES IDEALES Q3
8.00
Fondo
6.00
yc
Coordenada profundidad
normal
4.00
Coordenada profundidad
crtica
cm
yn
Profundidad experimental
2.00
y
0.00
0.00
50.00
100.00
150.00
Fondo=S0.x
200.00
250.00
300.00
350.00
400.00
450.00
-2.00
-4.00
Longitud (cm)
HIDRAULICA II
1.1.8
Condiciones de flujo
El Flujo Uniforme est regulado por las caractersticas del canal (pendiente, rugosidad,
propiedades geomtricas) y el caudal adems de las profundidades normal y crtica.
Tabla.101 RESUMEN
RESUMEN
Q
4.8038
8.4082
9.1225
yn
2.35
2.28
2.32
yc
3.82
5.55
5.86
n
0.0013
0.0007
0.0007
C
408.82
748.12
789.53
Fr
2.07
3.80
4.01
Variacin de n con Q
0.0014
0.0012
0.0010
0.0008
0.0006
0.0004
0.0002
0.0000
0.0000
2.0000
4.0000
Q (LPS)
6.0000
8.0000
10.0000
HIDRAULICA II
La profundidad real muestra una tendencia a aumentar tal como en el perfil tpico
que se esperara de un Flujo Gradualmente variado incluso bajo las condiciones
estables de los experimentos. Dicha profundidad converge a un valor medio y estable
tal como la profundidad normal.
El valor encontrado del Coeficiente de Rugosidad "n" de Manning (aprox. 0,002) para
el tipo de canal (acrlico) es de los ms bajos referidos en la literatura, incluso menor
al del PVC cuya magnitud promedio es de 0,009, de hecho segn los resultados su
magnitud es proporcional al caudal (disminuye mientras este aumenta) indicando
posiblemente que no es un valor constante o que est correlacionado con otra
variable.
En todos los casos el flujo es supercrtico, demostrado esto por los Nmeros de
Froude (mayores a 1) y la permanencia de la lmina de agua por debajo de la
profundidad crtica, esta situacin puede asimilarse a un flujo rpido.
HIDRAULICA II
Pudimos determinar que los valores encontrados corresponden a las caractersticas de flujo
uniforme algo muy importante ya que comprueba todo lo estudiado en la teora.
Podemos obtener el tipo de flujo que observamos en la prctica de acuerdo con las
lneas de pendientes o tambin por medio del nmero de froude hallado
tericamente.
HIDRAULICA II
INTRODUCCIN
Se define el flujo gradualmente
variado como el flujo permanente en el cual la
profundidad vara con la distancia longitudinal de forma gradual. Estas situaciones se
pueden presentar aguas arriba o aguas abajo de secciones de control como en el caso
de vertederos, estructuras de cada o entradas de alcantarillas. La profundidad del
flujo gradualmente variado por lo general se representa por la profundidad y, sin utilizar
subndice.
Para el diseo de canales, es necesario conocer los principios que rigen el flujo gradualmente
variado, con el fin de analizar el comportamiento del flujo cuando se producen cambios en
la rugosidad, el tamao de la seccin transversal, la forma o la pendiente del canal. El
objetivo principal en el anlisis del flujo gradualmente variado es predecir el perfil que
tendr la superficie libre en un
canal cuyo caudal es permanente.
En un canal pueden existir secciones donde la profundidad del agua est forzada a
tener un valor diferente del correspondiente a la tirante normal. En estos casos, el
perfil de la superficie lquida tiene que variar en forma gradual.
La forma adoptada por la superficie del agua donde ocurre la transicin entre esas dos
profundidades se denomina perfil del flujo.
OBJETIVO GENERAL
Analizar el comportamiento del flujo gradualmente variado en un canal.
OBJETIVOS ESPECIFICOS.
HIDRAULICA II
HIDRAULICA II
Datos de Laboratorio
Tabla 2.1 Datos obtenidos en laboratorio
PIEZ. No.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Hv
LECTURA INICIAL
Horizontal
Inclinada
21.7
19.5
21.7
19.4
21.7
19.2
21.7
19
21.7
18.7
21.7
18.5
21.7
18.1
21.7
17.8
21.7
17.6
21.7
17.3
21.7
17
21.7
16.6
21.7
16.3
21.6
15.8
14.4
Q1
hpiez
21
20.9
20.7
20.6
20.5
20.2
20
16.8
19.5
19.3
22.5
23.5
24
24.2
Q2
Y
1.7
1.8
1.9
2
2.1
2.2
2.2
2.4
2.4
2.4
6.5
7.2
8.2
8.4
hpiez
21
21
20.8
20.6
20.5
20.2
23.5
27
27.7
28
28
28
28
28.2
23.8
Q3
Y
1.7
1.8
1.8
1.9
2
2.2
2.6
9.1
10
11
11.3
11.6
12.2
12.7
25.1
LECTURA
ABERTURA
PENDIENTE DEL ANCHO DEL INICIAL DEL
DE LA
CANAL (S0)
CANAL (b cm) VERTEDERO COMPUERTA
(H0 cm)
(a cm)
0.00923
HIDRAULICA II
20.55
10.8
2.5
hpiez
21
20.9
20.8
20.8
28
30
30.3
30.6
30.7
30.7
30.7
30.7
30.7
31
Y
1.8
2
2
2.1
11.4
11.6
11.9
12.3
12.6
13.2
13.6
14
14.4
15.1
26
H = (Hv - H0)
Q (0,0172H2,34)
HIDRAULICA II
0.3446
344.569076
lps
cm3
Q1
Q2
Q3
13
14.3
15.2
6.9527
LPS
8.6899
LPS
10.0240
LPS
6952.74
0.0070
cm3/s
m3/s
8689.90
0.0087
cm3/s
m3/s
10024.03
0.0100
cm3/s
m3/s
Altura
Profundidad
piezomtrica
21.00
20.90
20.70
20.60
20.50
20.20
20.00
16.80
19.50
19.30
22.50
23.50
24.00
24.20
PENDIENTE
0.00731
PROMEDIO
26.8867
1.70
1.80
1.90
2.00
2.10
2.20
2.20
2.40
2.40
2.40
6.50
7.20
8.20
8.40
ynormal
2.6760
Q1 = 6.95 lps
29.00
24.00
Altura piezomtrica
Altura (cm)
19.00
Profundidad
experimental
14.00
Altura piezomtrica
inicial
9.00
4.00
-1.00
Lineal (Altura
piezomtrica inicial)
h0
0
50
100
150
200
250
300
350
400
450
Grfica 2.7 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q1
HIDRAULICA II
21.00
21.00
20.80
20.60
20.50
20.20
23.50
27.00
27.70
28.00
28.00
28.00
28.00
28.20
PENDIENTE
0.02508
PROMEDIO
31.8507
1.70
1.80
1.80
1.90
2.00
2.20
2.60
9.10
10.00
11.00
11.30
11.60
12.20
12.70
ynormal
3.3181
Altura piezomtrica
19.00
Profundidad experimental
14.00
9.00
Lineal (Altura piezomtrica
inicial)
4.00
-1.00
h0
0
50
100
150
200
250
300
350
400
450
Grfica 2.8 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q2
HIDRAULICA II
21.00
20.90
20.80
20.80
28.00
30.00
30.30
30.60
30.70
30.70
30.70
30.70
30.70
31.00
PENDIENTE
0.02928
PROMEDIO
36.2271
1.80
2.00
2.00
2.10
11.40
11.60
11.90
12.30
12.60
13.20
13.60
14.00
14.40
15.10
ynormal
3.4537
h
29.00
Altura piezomtrica
Altura (cm)
24.00
19.00
Profundidad
experimental
14.00
Altura piezomtrica
inicial
9.00
Lineal (Altura
piezomtrica inicial)
4.00
-1.00
h0
0
50
100
150
200
250
300
350
400
450
Grfica 2.3 Variacin de la altura PZ promedio en funcin de la longitud del canal para Q2
HIDRAULICA II
Q
Q1
Q2
Q3
R(m)
0.0212
0.0251
0.03
Tabla 2.15 Condiciones ideales y experimentales de acuerdo al fondo del canal para Q1
CONDICIONES IDEALIZADAS Y EXPERIMENTALES REFERIDAS AL FONDO DEL CANAL
6.95LPS
Fondo
0.00
30.33
60.67
91.00
121.00
151.00
181.00
214.00
247.00
280.00
309.50
339.00
368.50
398.00
0.00
-0.28
-0.56
-0.84
-1.12
-1.39
-1.67
-1.97
-2.28
-2.58
-2.86
-3.13
-3.40
-3.67
HIDRAULICA II
Profundidad Coordenada
Altura
experiment profundidad
piezomtrica
al
normal
Videal
(cm/s)
Altura de
velocidad
Coordenada
Altura de
profundidad
energa
crtica
1.70
1.52
1.34
1.16
0.98
0.81
0.53
0.43
0.12
-0.18
3.64
4.07
4.80
4.73
2.68
2.40
2.12
1.84
1.56
1.28
1.01
0.70
0.40
0.09
-0.18
-0.45
-0.72
-1.00
21.00
20.90
20.70
20.60
20.50
20.20
20.00
16.80
19.50
19.30
22.50
23.50
24.00
24.20
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
126.43
8.15
7.87
7.59
7.31
7.03
6.75
6.48
6.17
5.87
5.56
5.29
5.02
4.75
4.48
10.82
10.26
9.70
9.14
8.59
8.04
7.48
6.88
6.27
5.66
5.11
4.57
4.02
3.48
yn (cm)
2.6760
q (m3/s.m)
0.0338
n
0.0030
C
175.40
yc (cm)
4.8866
Fr
-
4.89
4.61
4.33
4.05
3.77
3.49
3.22
2.91
2.61
2.30
2.03
1.76
1.49
1.21
Profundida
d
x (m)
experiment
al (m)
0.0000
0.0170
0.3033
0.0152
0.6067
0.0134
0.9100
0.0116
1.2100
0.0098
1.5100
0.0081
1.8100
0.0053
2.1400
0.0043
2.4700
0.0012
2.8000 -0.0018
3.0950
0.0364
3.3900
0.0407
3.6850
0.0480
3.9800
0.0473
Fondo
5.00
Coordenada
profundidad normal
4.00
3.00
Coordenada
profundidad crtica
cm
2.00
yc
1.00
Profundidad
experimental
0.00
-1.00
-2.00
yn
-3.00
Fondo=S0.x
-4.00
-5.00
0.00
100.00
200.00
300.00
400.00
500.00
Longitud (cm)
8.69LPS
Fondo
0.00
30.33
60.67
91.00
121.00
151.00
181.00
214.00
247.00
280.00
309.50
339.00
368.50
398.00
0.00
-0.28
-0.56
-0.84
-1.12
-1.39
-1.67
-1.97
-2.28
-2.58
-2.86
-3.13
-3.40
-3.67
HIDRAULICA II
Profundidad Coordenada
Altura
experiment profundidad
piezomtrica
al
normal
Videal
(cm/s)
Altura de
velocidad
Coordenada
Altura de
profundidad
energa
crtica
1.70
1.52
1.24
1.06
0.88
0.81
0.93
7.13
7.72
8.42
8.44
8.47
8.80
9.03
3.32
3.04
2.76
2.48
2.20
1.93
1.65
1.34
1.04
0.74
0.46
0.19
-0.08
-0.35
21.00
21.00
20.80
20.60
20.50
20.20
23.50
27.00
27.70
28.00
28.00
28.00
28.00
28.20
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
127.44
8.28
8.00
7.72
7.44
7.16
6.88
6.61
6.30
6.00
5.69
5.42
5.15
4.88
4.61
11.60
11.04
10.48
9.92
9.36
8.81
8.26
7.65
7.04
6.43
5.89
5.34
4.80
4.25
yn (cm)
3.32
q (m3/s.m)
0.0423
n
0.0030
C
180.35
yc (cm)
5.67
Fr
-
5.67
5.39
5.11
4.83
4.55
4.28
4.00
3.70
3.39
3.09
2.81
2.54
2.27
2.00
Profundida
d
x (m)
experiment
al (m)
0.0000
0.0170
0.3033
0.0152
0.6067
0.0124
0.9100
0.0106
1.2100
0.0088
1.5100
0.0081
1.8100
0.0093
2.1400
0.0713
2.4700
0.0772
2.8000
0.0842
3.0950
0.0844
3.3900
0.0847
3.6850
0.0880
3.9800
0.0903
8.00
Coordenada profundidad crtica
Profundidad experimental
6.00
yc
4.00
cm
yn
2.00
y
0.00
Fondo=S0.x
-2.00
Longitud (cm)
-4.00
0.00
50.00
100.00
150.00
200.00
250.00
300.00
350.00
400.00
450.00
10.02LPS
Fondo
0.00
30.33
60.67
91.00
121.00
151.00
181.00
214.00
247.00
280.00
309.50
339.00
368.50
398.00
0.00
-0.28
-0.56
-0.84
-1.12
-1.39
-1.67
-1.97
-2.28
-2.58
-2.86
-3.13
-3.40
-3.67
HIDRAULICA II
Profundidad Coordenada
Altura
experiment profundidad
piezomtrica
al
normal
Videal
(cm/s)
Altura de
velocidad
Altura de
energa
Coordenada
profundidad
crtica
6.24
5.96
5.68
5.40
5.12
4.84
4.57
4.26
3.96
3.65
3.38
3.11
2.84
2.56
1.80
1.72
1.44
1.26
10.28
10.21
10.23
10.33
10.32
10.62
10.74
10.87
11.00
11.43
3.45
3.17
2.89
2.61
2.34
2.06
1.78
1.48
1.18
0.87
0.60
0.33
0.05
-0.22
21.00
20.90
20.80
20.80
28.00
30.00
30.30
30.60
30.70
30.70
30.70
30.70
30.70
31.00
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
141.24
10.17
9.89
9.61
9.33
9.05
8.77
8.50
8.19
7.89
7.58
7.31
7.04
6.77
6.50
13.62
13.06
12.50
11.94
11.39
10.83
10.28
9.67
9.06
8.45
7.91
7.37
6.82
6.28
yn (cm)
3.45
q (m3/s.m)
0.0488
n
0.0030
C
181.25
yc (cm)
6.24
Fr
-
Profundida
d
x (m)
experiment
al (m)
0.0000
0.0180
0.3033
0.0172
0.6067
0.0144
0.9100
0.0126
1.2100
0.1028
1.5100
0.1021
1.8100
0.1023
2.1400
0.1033
2.4700
0.1032
2.8000
0.1062
3.0950
0.1074
3.3900
0.1087
3.6850
0.1100
3.9800
0.1143
HIDRAULICA II
Perfiles Obtenidos
Tabla 2.11 Condiciones perfil Q1
yCalculada
0.0840
0.0173
0.0172
0.0172
0.0172
0.0172
0.0172
0.0171
0.0171
0.0171
0.0171
0.0171
0.0170
0.0170
0.0170
0.0170
0.0170
0.0169
0.0169
0.0169
0.0168
0.0167
0.0166
0.0165
0.0164
0.0163
0.0162
0.0161
0.0160
0.0160
0.0160
0.0159
0.4028
0.4033
0.4037
0.4042
0.4047
0.4052
0.4057
0.4062
0.4066
0.4071
0.4076
0.4081
0.4086
0.4091
0.4096
0.4101
0.4106
0.4111
0.4116
0.4141
0.4167
0.4192
0.4219
0.4245
0.4272
0.4299
0.4327
0.4338
0.4346
0.4354
0.4363
0.0923
0.0922
0.0921
0.0920
0.0919
0.0919
0.0918
0.0917
0.0916
0.0915
0.0915
0.0914
0.0913
0.0912
0.0912
0.0911
0.0910
0.0909
0.0908
0.0904
0.0900
0.0897
0.0893
0.0889
0.0885
0.0881
0.0877
0.0876
0.0875
0.0874
0.0873
0.3735
0.3733
0.3731
0.3729
0.3727
0.3725
0.3723
0.3721
0.3719
0.3717
0.3715
0.3713
0.3711
0.3709
0.3707
0.3705
0.3703
0.3701
0.3699
0.3689
0.3679
0.3669
0.3659
0.3649
0.3639
0.3629
0.3619
0.3615
0.3612
0.3609
0.3606
0.0462
0.0462
0.0462
0.0461
0.0461
0.0461
0.0460
0.0460
0.0460
0.0459
0.0459
0.0459
0.0459
0.0458
0.0458
0.0458
0.0457
0.0457
0.0457
0.0455
0.0454
0.0452
0.0450
0.0449
0.0447
0.0446
0.0444
0.0443
0.0443
0.0442
0.0442
0.0840
0.0839
0.0838
0.0837
0.0836
0.0835
0.0834
0.0833
0.0832
0.0831
0.0830
0.0829
0.0828
0.0827
0.0826
0.0825
0.0824
0.0823
0.0820
0.0815
0.0810
0.0805
0.0800
0.0795
0.0790
0.0785
0.0781
0.0779
0.0778
0.0776
0.0035
0.0035
0.0035
0.0035
0.0035
0.0035
0.0035
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
1.9902
1.9855
1.9809
1.9762
1.9716
1.9671
1.9625
1.9579
1.9534
1.9489
1.9444
1.9400
1.9355
1.9322
1.9289
1.9256
1.9223
1.9191
1.9158
1.9126
1.9093
1.9061
1.9029
1.8997
1.8965
1.8933
1.8901
1.8870
1.8838
1.8807
1.8775
0.2189
0.2180
0.2171
0.2162
0.2153
0.2144
0.2135
0.2127
0.2118
0.2110
0.2101
0.2093
0.2084
0.2078
0.2072
0.2066
0.2059
0.2053
0.2047
0.2041
0.2035
0.2029
0.2023
0.2017
0.2012
0.2006
0.2000
0.1994
0.1988
0.1983
0.1977
0.2395
0.2396
0.2397
0.2397
0.2398
0.2399
0.2400
0.2401
0.2401
0.2402
0.2403
0.2404
0.2405
0.2405
0.2406
0.2406
0.2407
0.2408
0.2408
0.2409
0.2409
0.2410
0.2411
0.2411
0.2412
0.2412
0.2413
0.2414
0.2414
0.2415
0.2415
0.0146
0.0146
0.0146
0.0147
0.0147
0.0147
0.0148
0.0148
0.0148
0.0149
0.0149
0.0149
0.0149
0.0150
0.0150
0.0150
0.0150
0.0150
0.0151
0.0151
0.0151
0.0151
0.0152
0.0152
0.0152
0.0152
0.0152
0.0153
0.0153
0.0153
0.0153
0.0170
0.0171
0.0171
0.0171
0.0172
0.0172
0.0173
0.0173
0.0173
0.0174
0.0174
0.0175
0.0175
0.0175
0.0176
0.0176
0.0176
0.0176
0.0177
0.0177
0.0177
0.0178
0.0178
0.0178
0.0179
0.0179
0.0179
0.0179
0.0180
0.0180
0.0839
0.0838
0.0837
0.0836
0.0835
0.0834
0.0833
0.0832
0.0831
0.0830
0.0829
0.0828
0.0827
0.0826
0.0825
0.0824
0.0823
0.0822
0.0817
0.0812
0.0807
0.0802
0.0797
0.0792
0.0787
0.0782
0.0780
0.0778
0.0777
0.0776
0.017000
0.017040
0.017080
0.017120
0.017160
0.017200
0.017240
0.017280
0.017320
0.017360
0.017400
0.017440
0.017480
0.017510
0.017540
0.017570
0.017600
0.017630
0.017660
0.017690
0.017720
0.017750
0.017780
0.017810
0.017840
0.017870
0.017900
0.017930
0.017960
0.017990
0.018020
HIDRAULICA II
ym
S (ym)
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.04
-0.04
-0.04
-0.04
-0.04
-0.04
-0.04
-0.04
-0.02
-0.01
-0.01
-0.01
0.00
-0.01
-0.02
-0.03
-0.04
-0.04
-0.05
-0.06
-0.07
-0.08
-0.09
-0.10
-0.10
-0.11
-0.12
-0.13
-0.14
-0.15
-0.16
-0.20
-0.24
-0.29
-0.33
-0.37
-0.41
-0.45
-0.50
-0.51
-0.53
-0.54
-0.55
0.0099
0.0099
0.0098
0.0097
0.0096
0.0096
0.0095
0.0094
0.0094
0.0093
0.0092
0.0092
0.0091
0.0091
0.0090
0.0090
0.0089
0.0089
0.0088
0.0088
0.0087
0.0087
0.0086
0.0086
0.0086
0.0085
0.0085
0.0084
0.0084
0.0083
1.29
1.43
1.60
1.82
2.12
2.53
3.14
4.15
6.13
11.79
161.27
-13.74
-5.66
-3.90
-2.97
-2.40
-2.01
-1.73
-1.52
-1.35
-1.22
-1.11
-1.01
-0.94
-0.87
-0.81
-0.76
-0.71
-0.67
-0.64
0.00
1.29
2.72
4.32
6.14
8.26
10.79
13.93
18.08
24.21
36.00
197.27
183.53
177.87
173.97
170.99
168.59
166.58
164.85
163.33
161.98
160.77
159.66
158.65
157.71
156.84
156.04
155.28
154.56
153.89
153.25
yCalculada
Fondo
yc
yn
yCalculada
Fondo
yc
yn
Profundidad conjugada
Profundidad experimental (m)
PERFILES FGV Q1
0.1100
yConjugada
0.0900
0.0700
x=f(y1)
Profundidad (m)
0.0500
S1
Longitud
resalto
0.0300
LPC
yExperimental
0.0100
x=f(y2)
LPN
S3
-0.0100
-0.0300
-0.0500
1.50
2.00
2.50
3.00
Longitud (m)
HIDRAULICA II
3.50
4.00
4.50
0.1270
0.0261
0.0260
0.0260
0.0259
0.0259
0.0258
0.0258
0.0257
0.0257
0.0257
0.0256
0.0256
0.0255
0.0255
0.0255
0.0255
0.0255
0.0254
0.0254
0.0254
0.0254
0.0254
0.0254
0.0254
0.0254
0.0253
0.0252
0.0251
0.0251
0.0251
0.0250
0.3330
0.3343
0.3348
0.3353
0.3359
0.3364
0.3369
0.3375
0.3380
0.3386
0.3391
0.3397
0.3402
0.3407
0.3410
0.3413
0.3414
0.3416
0.3417
0.3418
0.3420
0.3421
0.3423
0.3424
0.3425
0.3439
0.3453
0.3459
0.3463
0.3468
0.3472
0.1327
0.1322
0.1320
0.1318
0.1316
0.1315
0.1313
0.1311
0.1309
0.1307
0.1306
0.1304
0.1302
0.1300
0.1299
0.1298
0.1298
0.1297
0.1297
0.1297
0.1296
0.1296
0.1295
0.1295
0.1294
0.1290
0.1285
0.1283
0.1282
0.1281
0.1279
0.4595
0.4585
0.4581
0.4577
0.4573
0.4569
0.4565
0.4561
0.4557
0.4553
0.4549
0.4545
0.4541
0.4537
0.4535
0.4533
0.4532
0.4531
0.4530
0.4529
0.4528
0.4527
0.4526
0.4525
0.4524
0.4514
0.4504
0.4500
0.4497
0.4494
0.4491
0.0568
0.0567
0.0567
0.0566
0.0566
0.0565
0.0565
0.0565
0.0564
0.0564
0.0563
0.0563
0.0563
0.0562
0.0562
0.0562
0.0562
0.0561
0.0561
0.0561
0.0561
0.0561
0.0561
0.0561
0.0561
0.0560
0.0559
0.0558
0.0558
0.0558
0.0557
0.1268
0.1264
0.1262
0.1260
0.1258
0.1256
0.1254
0.1252
0.1250
0.1248
0.1246
0.1244
0.1242
0.1241
0.1240
0.1239
0.1238
0.1238
0.1237
0.1237
0.1236
0.1236
0.1235
0.1235
0.1232
0.1227
0.1224
0.1222
0.1220
0.1219
0.0035
0.0035
0.0035
0.0035
0.0035
0.0035
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0036
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0037
0.0038
2.4874
2.4802
2.4729
2.4657
2.4585
2.4514
2.4443
2.4373
2.4303
2.4233
2.4164
2.4095
2.4026
2.3958
2.3891
2.3823
2.3757
2.3690
2.3624
2.3558
2.3493
2.3427
2.3363
2.3337
2.3311
2.3286
2.3260
2.3234
2.3209
2.3183
2.3158
0.3324
0.3306
0.3288
0.3270
0.3253
0.3235
0.3218
0.3201
0.3184
0.3168
0.3151
0.3135
0.3118
0.3102
0.3086
0.3070
0.3055
0.3039
0.3023
0.3008
0.2993
0.2978
0.2963
0.2957
0.2951
0.2945
0.2939
0.2933
0.2928
0.2922
0.2916
0.2395
0.2396
0.2397
0.2398
0.2399
0.2400
0.2401
0.2402
0.2403
0.2404
0.2405
0.2406
0.2407
0.2408
0.2409
0.2410
0.2411
0.2412
0.2413
0.2414
0.2415
0.2416
0.2417
0.2417
0.2418
0.2418
0.2419
0.2419
0.2419
0.2420
0.2420
0.0146
0.0146
0.0147
0.0147
0.0147
0.0148
0.0148
0.0148
0.0149
0.0149
0.0150
0.0150
0.0150
0.0151
0.0151
0.0151
0.0152
0.0152
0.0152
0.0153
0.0153
0.0154
0.0154
0.0154
0.0154
0.0154
0.0154
0.0155
0.0155
0.0155
0.0155
0.0170
0.0171
0.0171
0.0172
0.0172
0.0173
0.0173
0.0174
0.0174
0.0175
0.0175
0.0176
0.0176
0.0177
0.0177
0.0178
0.0178
0.0179
0.0179
0.0180
0.0180
0.0181
0.0181
0.0181
0.0182
0.0182
0.0182
0.0182
0.0182
0.0183
0.1265
0.1263
0.1261
0.1259
0.1257
0.1255
0.1253
0.1251
0.1249
0.1247
0.1245
0.1243
0.1241
0.1240
0.1239
0.1239
0.1238
0.1238
0.1237
0.1237
0.1236
0.1236
0.1235
0.1235
0.1230
0.1225
0.1223
0.1221
0.1220
0.1218
0.017000
0.017050
0.017100
0.017150
0.017200
0.017250
0.017300
0.017350
0.017400
0.017450
0.017500
0.017550
0.017600
0.017650
0.017700
0.017750
0.017800
0.017850
0.017900
0.017950
0.018000
0.018050
0.018100
0.018120
0.018140
0.018160
0.018180
0.018200
0.018220
0.018240
0.018260
HIDRAULICA II
ym
S (ym)
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0001
0.0001
0.0001
0.0001
0.0001
-0.05
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.01
-0.01
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
-0.05
-0.05
-0.02
-0.01
-0.01
-0.01
0.00
-0.05
-0.07
-0.09
-0.11
-0.13
-0.15
-0.17
-0.19
-0.21
-0.23
-0.25
-0.27
-0.29
-0.30
-0.31
-0.31
-0.32
-0.32
-0.33
-0.33
-0.34
-0.34
-0.35
-0.35
-0.40
-0.45
-0.47
-0.48
-0.50
-0.51
0.0155
0.0153
0.0152
0.0151
0.0149
0.0148
0.0147
0.0145
0.0144
0.0143
0.0141
0.0140
0.0139
0.0138
0.0136
0.0135
0.0134
0.0133
0.0132
0.0131
0.0129
0.0128
0.0128
0.0127
0.0127
0.0127
0.0126
0.0126
0.0125
0.0125
0.29
0.29
0.30
0.30
0.30
0.31
0.31
0.32
0.32
0.33
0.33
0.34
0.35
0.35
0.36
0.37
0.37
0.38
0.39
0.40
0.40
0.41
0.17
0.17
0.17
0.17
0.17
0.17
0.18
0.18
0.00
0.29
0.58
0.87
1.17
1.48
1.79
2.10
2.42
2.74
3.07
3.41
3.75
4.09
4.44
4.80
5.17
5.54
5.92
6.31
6.71
7.11
7.53
7.69
7.86
8.03
8.20
8.38
8.55
8.73
8.90
PERFILES FGV Q2
0.1500
yCalculada
Fondo
0.1300
yc
yConjugada
yn
yCalculada
0.1100
S1
Fondo
yc
0.0900
yn
x=f(y1)
Profundidad (m)
Profundidad conjugada
0.0700
Longitud
resalto
yExperimental
0.0500
0.0300
LPC
0.0100
x=f(y2)
S3
-0.0100
LPN
-0.0300
-0.0500
0.00
0.50
1.00
1.50
2.00
Longitud (m)
HIDRAULICA II
2.50
3.00
3.50
4.00
0.1510
0.0310
0.0309
0.0309
0.0308
0.0308
0.0308
0.0307
0.0307
0.0306
0.0306
0.0306
0.0305
0.0305
0.0304
0.0304
0.0304
0.0304
0.0304
0.0304
0.0304
0.0303
0.0303
0.0303
0.0303
0.0303
0.0302
0.0301
0.0301
0.0300
0.0300
0.0300
0.3230
0.3241
0.3245
0.3250
0.3254
0.3258
0.3263
0.3267
0.3272
0.3276
0.3280
0.3285
0.3289
0.3294
0.3296
0.3298
0.3299
0.3300
0.3301
0.3303
0.3304
0.3305
0.3306
0.3307
0.3308
0.3319
0.3331
0.3335
0.3339
0.3342
0.3346
0.1563
0.1559
0.1557
0.1555
0.1553
0.1551
0.1549
0.1547
0.1546
0.1544
0.1542
0.1540
0.1538
0.1536
0.1535
0.1534
0.1534
0.1534
0.1533
0.1533
0.1532
0.1532
0.1531
0.1531
0.1530
0.1526
0.1521
0.1519
0.1518
0.1516
0.1515
0.5075
0.5065
0.5061
0.5057
0.5053
0.5049
0.5045
0.5041
0.5037
0.5033
0.5029
0.5025
0.5021
0.5017
0.5015
0.5013
0.5012
0.5011
0.5010
0.5009
0.5008
0.5007
0.5006
0.5005
0.5004
0.4994
0.4984
0.4980
0.4977
0.4974
0.4971
0.0611
0.0611
0.0610
0.0610
0.0610
0.0609
0.0609
0.0609
0.0608
0.0608
0.0608
0.0607
0.0607
0.0607
0.0606
0.0606
0.0606
0.0606
0.0606
0.0606
0.0606
0.0606
0.0606
0.0606
0.0606
0.0605
0.0604
0.0604
0.0603
0.0603
0.0603
0.1508
0.1504
0.1502
0.1500
0.1498
0.1496
0.1494
0.1492
0.1490
0.1488
0.1486
0.1484
0.1482
0.1481
0.1480
0.1479
0.1478
0.1478
0.1477
0.1477
0.1476
0.1476
0.1475
0.1475
0.1472
0.1467
0.1464
0.1462
0.1460
0.1459
0.0037
0.0037
0.0037
0.0037
0.0037
0.0038
0.0038
0.0038
0.0038
0.0038
0.0038
0.0038
0.0038
0.0038
0.0038
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0039
0.0040
0.0040
2.7099
2.7024
2.6950
2.6875
2.6802
2.6728
2.6655
2.6582
2.6510
2.6438
2.6367
2.6296
2.6225
2.6155
2.6085
2.6015
2.5946
2.5877
2.5809
2.5741
2.5673
2.5606
2.5539
2.5512
2.5485
2.5459
2.5432
2.5406
2.5379
2.5353
2.5326
0.3923
0.3903
0.3883
0.3863
0.3843
0.3824
0.3804
0.3785
0.3766
0.3747
0.3728
0.3710
0.3691
0.3673
0.3655
0.3637
0.3619
0.3602
0.3584
0.3567
0.3549
0.3532
0.3515
0.3509
0.3502
0.3495
0.3488
0.3482
0.3475
0.3468
0.3462
0.2415
0.2416
0.2417
0.2418
0.2419
0.2420
0.2421
0.2422
0.2423
0.2424
0.2425
0.2426
0.2427
0.2428
0.2429
0.2430
0.2431
0.2432
0.2433
0.2434
0.2435
0.2436
0.2437
0.2437
0.2438
0.2438
0.2439
0.2439
0.2439
0.2440
0.2440
0.0153
0.0154
0.0154
0.0154
0.0155
0.0155
0.0155
0.0156
0.0156
0.0156
0.0157
0.0157
0.0157
0.0158
0.0158
0.0159
0.0159
0.0159
0.0160
0.0160
0.0160
0.0161
0.0161
0.0161
0.0161
0.0161
0.0162
0.0162
0.0162
0.0162
0.0162
0.0180
0.0181
0.0181
0.0182
0.0182
0.0183
0.0183
0.0184
0.0184
0.0185
0.0185
0.0186
0.0186
0.0187
0.0187
0.0188
0.0188
0.0189
0.0189
0.0190
0.0190
0.0191
0.0191
0.0191
0.0192
0.0192
0.0192
0.0192
0.0192
0.0193
0.1505
0.1503
0.1501
0.1499
0.1497
0.1495
0.1493
0.1491
0.1489
0.1487
0.1485
0.1483
0.1481
0.1480
0.1479
0.1479
0.1478
0.1478
0.1477
0.1477
0.1476
0.1476
0.1475
0.1475
0.1470
0.1465
0.1463
0.1461
0.1460
0.1458
0.018000
0.018050
0.018100
0.018150
0.018200
0.018250
0.018300
0.018350
0.018400
0.018450
0.018500
0.018550
0.018600
0.018650
0.018700
0.018750
0.018800
0.018850
0.018900
0.018950
0.019000
0.019050
0.019100
0.019120
0.019140
0.019160
0.019180
0.019200
0.019220
0.019240
0.019260
HIDRAULICA II
ym
S (ym)
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
-0.05
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.02
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.05
-0.05
-0.02
-0.02
-0.02
-0.02
0.00
-0.05
-0.07
-0.09
-0.11
-0.13
-0.15
-0.17
-0.19
-0.21
-0.23
-0.25
-0.27
-0.29
-0.30
-0.31
-0.32
-0.32
-0.33
-0.33
-0.34
-0.34
-0.35
-0.35
-0.36
-0.41
-0.46
-0.48
-0.49
-0.51
-0.52
0.0172
0.0171
0.0169
0.0168
0.0166
0.0165
0.0164
0.0162
0.0161
0.0159
0.0158
0.0157
0.0155
0.0154
0.0153
0.0152
0.0150
0.0149
0.0148
0.0147
0.0146
0.0144
0.0144
0.0143
0.0143
0.0142
0.0142
0.0142
0.0141
0.0141
0.25
0.26
0.26
0.26
0.26
0.27
0.27
0.27
0.28
0.28
0.28
0.29
0.29
0.29
0.30
0.30
0.30
0.31
0.31
0.32
0.32
0.33
0.13
0.13
0.13
0.13
0.13
0.13
0.14
0.14
0.00
0.25
0.51
0.77
1.03
1.29
1.56
1.83
2.10
2.37
2.65
2.93
3.22
3.51
3.80
4.10
4.40
4.70
5.01
5.32
5.64
5.96
6.29
6.42
6.55
6.68
6.81
6.95
7.08
7.22
7.36
HIDRAULICA II
Segn los tipos de perfil de flujo podemos determinar que los caudales que trabajamos son
M o sea con una pendiente moderada esto es posible verlo porque el flujo gradualmente
variado comienza en la zona 1, justo arriba de la LPN, para los tres casos. Sin embargo debajo
de la LPN se ve un fenmeno de resalto porque la lmina de agua cruza la lnea de pendiente
crtica, luego el perfil debajo de la LPN es crtico y corresponde a flujo rpidamente variado.
Por las pendientes que utilizamos vemos reflejado en el nmero de froude que tenemos un
flujo subcritico.
Para el caso de canales de pendiente suave (canal M), se distinguen.M1 si se encuentra por
sobre el .
La altura de la lmina de agua aguas arriba de la compuerta fue posible hallarla con base a la
ecuacin de caudal para compuertas en funcin del rea de la seccin del canal, mediante la
ecuacin cbica descrita anteriormente. Adicionalmente fue posible calcular la constante por
vena contracta C, a travs de la lectura de la lmina de agua aguas debajo de la compuerta y
la abertura de la compuerta, con lo cual la frmula era aplicable.
HIDRAULICA II
Se determino que para el flujo gradualmente variado: Los Flujos en un canal se caracterizan
por la velocidad media, aun cuando exista un perfil de velocidad en una seccin dada. El flujo
se clasifica en una combinacin de continuo o discontinuo, y de uniforme o no uniforme.
El flujo es rpidamente variado si la profundidad del agua cambia de manera abrupta en distancias
comparativamente cortas; de otro modo es gradualmente variado.
El flujo variado en canales compuestos siguen los mismos lineamentos del flujo uniforme y es
poco til en la practica si no se plantean hiptesis simplificadoras, pues se deben considerar
a adems de las condiciones en que ocurren los perfiles de flujo debido al poder existir mas
de un tirante critico para un mismo gasto.
El flujo de nuestro laboratorio es Sbucritico en este caso de flujo subcrtico, tambin denominado
flujo lento, el nivel efectivo del agua en una seccin determinada est condicionado al nivel de la
seccin aguas abajo.
HIDRAULICA II
INTRODUCCIN
Las chimeneas de equilibrio son tneles verticales abiertos que se sitan cerca del elemento que
provoca el golpe de ariete. De esta forma, la condicin de contorno se transforma en la de un
depsito (no ideal), convirtiendo la pulsacin de alta intensidad y frecuencia del golpe de ariete en
una pulsacin de baja intensidad y frecuencia, correspondiente a una oscilacin en masa. Es habitual
su utilizacin en centrales hidrulicas para proteger los tneles de hormign anteriores a las tuberas
forzadas En la, instalacin y funcionamiento de ciertas estructuras hidrulicas es necesario un control
de estos dos fenmenos: golpe de ariete y cavitacin, que originan sobrepresiones o depresiones
excesivas y que pueden conducir a averas, llegando hasta la destruccin misma de la estructura o de
la mquina. Este laboratorio se centrar en describir la teora asociada al fenmeno transitorio del
golpe de ariete.
Este fenmeno se produce en los conductos al cerrar o abrir una vlvula y al poner en marcha o parar
una mquina hidrulica, o tambin al disminuir bruscamente el caudal. Un caso muy comn es el
que ocurre en las centrales hidrulicas, donde se ha de reducir bruscamente el caudal.
OBJETIVO GENERAL
Conocer el mecanismo de funcionamiento de la chimenea de equilibrio as como tambin las
ecuaciones con las cuales se maneja este tipo de mecanismo y relacionar los resultados obtenidos en
laboratorio con los calculados.
OBJETIVOS ESPECIFICOS.
Analizar los casos que se pueden presentar al momento de cerrar o abrir una vlvula
Por medio de las expresiones tericas, calcular todos los elementos necesarios para analizar
el funcionamiento de la chimenea de equilibrio
Implementar el mtodo de clculo para determinar las diferentes variables que integran el
anlisis del fenmeno.
HIDRAULICA II
MARCO TERICO
La chimenea de equilibrio es un dispositivo que reduce las variaciones de presin en una tubera
mientras dura el rgimen no permanente .
El golpe de ariete es un fenmeno que se produce en una tubera forzada por el efecto de fluctuacin
del caudal circulante, y que se traduce en una variacin de la presin interna en la tubera, por
encima o por debajo de la presin de trabajo. La figura 1 representa una tubera de longitud L,
espesor y dimetro interior D por la que circula agua proveniente de un depsito aguas arriba y que
termina en una vlvula en su extremo derecho. Si se cierra sta rpidamente, en virtud del principio
de conservacin de la energa, al disminuir la energa cintica, sta se va transformando en un
trabajo de compresin del fluido que llena la tubera as como en un trabajo necesario para dilatar
esta ltima: golpe de arietepositivo. Por el contrario, al abrir rpidamente una vlvula se puede
producir una depresin: golpe de ariete negativo.
HIDRAULICA II
HIDRAULICA II
Datos de Laboratorio
Los datos rrecopilados en la prctica fueron recopilados en la presente tabla de registro.
Q1
Q2
Q3
122
111.5
99.5
Zo (cm)
13.5
24
36
145.5
146
145.6
145.5
146
146
146.6
146.1
146
10.43
10.38
9.49
11.01
10.06
9.51
10.67
9.71
9.17
Inc.
120
140
130
Fin.
150
160
150
Inc.
10.86
8.46
8.4
Zmax (cm)
t max (seg)
Peso W (kg)
Tiempo t (s)
NIVEL ESTATICO NE (cm)
Fin.
135.5
HIDRAULICA II
m (kg)
V=m/d (m/sg)
Q (cm/sg)
t(s)
A1(tub-cm) A4(chim-cm)
Zo
Vo(cm/s)
K1=(2g*Zo)/(Vo)
120.0000
0.1200
11049.7238
10.8600
11.4009
81.0734
13.5000
969.1937
0.0282
140.0000
0.1400
3546.0993
8.4600
11.4009
81.0734
24.0000
311.0356
0.4867
130.0000
0.1300
3571.4286
8.4000
11.4009
81.0734
36.0000
313.2572
0.7198
Q (cm/sg)
K1
Vo/2g
Iteracion
NE
Zmax
11049.7238
0.0282 -0.00010706
478.7647
122.0000
135.5
257.5000
3546.0993
0.4867 -0.00328544
49.3084
111.5000
135.5
247.0000
3571.4286
0.7198 -0.00728776
50.0153
99.5000
135.5
235.0000
HIDRAULICA II
Zmax Promedio
260
250
240
Series1
230
220
210
200
0
t max en (seg)
145.50
10.43
145.50
11.01
146.60
10.67
Q1 zmax - tmax
146.60
146.40
146.20
Series1
146.00
145.80
145.60
145.40
145.20
10.40
10.60
10.80
11.00
11.20
Grfica 3.2 Variacin de la altura PZmax promedio en funcin del tiempo del canal para
Q1
HIDRAULICA II
10.06
146.10
9.71
10.38
9.71
Q2 zmax - tmax
180.00
160.00
140.00
120.00
100.00
80.00
60.00
40.00
20.00
0.00
Ser
9.60
9.80
10.00
10.20
Grfica 3.3 Variacin de la altura Zmax promedio en funcin del tiempo del canal para Q2
Tabla 3.5 Profundidad Zmax Vs T en Q3
CAUDALES Q3
Zmax en (cm) t max en (seg)
145.60
9.49
146.00
9.51
146.00
9.17
Q3 zmax - tmax
146.10
146.05
146.00
145.95
145.90
145.85
145.80
145.75
145.70
145.65
145.60
145.55
Se
9.10
9.20
9.30
9.40
9.50
9.60
Grfica 3.4 Variacin de la altura Zmax promedio en funcin del tiempo del canal para Q3
HIDRAULICA II
Se observ que los valores de Zmax, para cada caudal permanecen constantes.
Mediante los datos recolectados fue posible el clculo de distintos caudales segn las
caractersticas descritas anteriormente.
En las grficas se puede observar que para z entre 0 y 140cm, el valor de Zmx resulta
negativo y adems se mantiene constante a partir de un punto en z.
HIDRAULICA II
Para la reduccin del golpe de ariete se tienen, bsicamente, dos posibilidades: bien actuar sobre la
fuente que produce la perturbacin, o bien reducirla una vez que sta se ha producido. El primer
sistema es el ms aconsejable, pero no siempre es posible su aplicacin.
Dentro de los medios para actuar sobre la fuente se tiene:
Aumentar los tiempos de apertura y cierre de las vlvulas.
Incrementar la inercia de bombas y turbinas.
Evitar vibraciones fluidodinmicas y posibles resonancias.
Dentro del mbito de aplicacin de actuacin sobre la perturbacin se encuentran:
Vlvulas de descarga.
Chimeneas de equilibrio.
\
HIDRAULICA II
4. LABORATORIO COMPUERTAS
INTRODUCCIN
Una Compuerta es una placa mvil, plana o curva, que al levantarse, forma un orificio entre su borde
inferior y la estructura hidrulica (presa, canal, etc.) sobre la cual se instala, y se utiliza en la mayora
de los casos para la regulacin de caudales, y como emergencia y cierre para mantenimiento en los
otros.
Las diferentes formas de las compuertas dependen de su aplicacin, el tipo de compuerta a utilizar
depender principalmente del tamao y forma del orificio, de la cabeza esttica, del espacio
disponible, del mecanismo de apertura y de las condiciones particulares de operacin.
Aplicaciones:
OBJETIVO GENERAL
Determinar los coeficientes de descarga (Cd) y contraccin (Cc), para la condicin de una apertura
constante, al tiempo que se determina la distribucin de presiones, tanto sobre la compuerta como
en el fondo del canal de prueba.
OBJETIVOS ESPECIFICOS.
Analizar la distribucin de presiones de velocidades a lo largo del fondo del canal y sobre la
pared de la compuerta.
Hallar los coeficientes de descarga y contraccin, para una compuerta cuando se mantiene
una abertura constante.
HIDRAULICA II
MARCO TERICO
Una compuerta es una puerta movible que se coloca en las esclusas de los canales y en los portillos
de las presas de ro para detener o dejar pasar las aguas. Las compuertas son equipos mecnicos
utilizados para el control del flujo del agua y mantenimiento en los diferentes proyectos de
ingeniera, tales como presas, canales y proyectos de irrigacin. Existen diferentes tipos y pueden
tener diferentes clasificaciones, segn su forma, funcin y su movimiento. Las diferentes formas de
las compuertas dependen de su aplicacin, el tipo de compuerta a utilizar depender principalmente
del tamao y forma del orificio, de la cabeza esttica, del espacio disponible, del mecanismo de
apertura y de las condiciones particulares de operacin. Aplicaciones: Control de flujos de aguas
Control de inundaciones Proyectos de irrigacin Crear reservas de agua Sistemas de drenaje
Proyectos de aprovechamiento de suelo Plantas de tratamiento de agua Incrementar capacidad de
reserva de las presas.
Por la ecuacin de energa se puede mostrar que la descarga a travs de una compuerta bajo el flujo
se puede expresar como:
Donde:
C : coeficiente de descarga
L : Longitud de la compuerta
h : Altura de la abertura de la compuerta
Y1 : Profundidad aguas arriba del flujo de llegada
V1 2/2g : es la altura de velocidad de flujo aprox.
Para estudios experimentales, el trmino de altura de velocidad se omite y su efecto se incluye en el
coeficiente as:
Ecuacin No.2
Donde C depende de la geometra de la estructura y de las profundidades aguas arriba y aguas abajo.
La ecuacin es la misma para flujo tanto libre como sumergido. Una compuerta sirve como
mecanismo de control de caudal en un canal.
HIDRAULICA II
HIDRAULICA II
Datos de Laboratorio
Tabla 4.17 Datos iniciales tomados en el laboratorio
PIEZA No.
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
ho
Y
Hv
Ho
LECTURA
INICIAL (cm)
0
0
0
0
0
28
28
28
28
28
2
18.8
12.5
10.8
a1 = 2cm
Ql
Qll
372.00 430.00
385.00 442.00
388.00 445.00
389.00 446.00
377.00 433.00
388.00 444.00
355.00 408.00
162.00 179.00
30.00 30.00
37.00 37.00
37.50 43.50
2.00
1.90
24.20 24.80
10.80 10.80
a2 = 2,5cm
Ql
Qll
302.00 415.00
312.00 430.00
315.00 432.00
315.00 433.00
328
435
313.00 432.00
278.00 383.00
145.00 174.00
37.00 41.00
37.00 45.00
30.00 71.50
2.20
2.10
25.20 25.80
10.80 10.80
HIDRAULICA II
a3 = 3cm
Ql
Qll
315.00 447.00
327.00 465.00
329.00 468.00
329.00 470.00
338.00 457.00
325.00 470.00
383.00 410.00
158.00 228.00
45.00 55.00
38.00 40.00
31.00 46.00
2.30
2.40
26.30 26.90
10.80 10.80
PIEZA No.
Expresin
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
ho
Y
Hv
Ho
H
Q
4.1.1
a1 = 2cm
Ql
372.00
385.00
388.00
389.00
377.00
388.00
355.00
162.00
30.00
37.00
37.50
2.00
24.20
10.80
13.40
7.52
Qll
430.00
442.00
445.00
446.00
433.00
444.00
408.00
179.00
30.00
37.00
43.50
1.90
24.80
10.80
14.00
8.34
a2 = 2,5cm
Ql
Qll
302.00
415.00
312.00
430.00
315.00
432.00
315.00
433.00
328.00
435.00
313.00
432.00
278.00
383.00
145.00
174.00
37.00
41.00
37.00
45.00
30.00
71.50
2.20
2.10
25.20
25.80
10.80
10.80
14.40
15.00
8.90
9.80
a3 = 3cm
Ql
315.00
327.00
329.00
329.00
338.00
325.00
383.00
158.00
45.00
38.00
31.00
2.30
26.30
10.80
15.50
10.58
Qll
447.00
465.00
468.00
470.00
457.00
470.00
410.00
228.00
55.00
40.00
46.00
2.40
26.90
10.80
16.10
11.56
Tabla Error! No hay texto con el estilo especificado en el documento..19 coeficientes de descarga
Cd
Usando la ecuacin
Cd
13.13
15.56
4.1.2
15.60
20.17
20.69
27.20
Tabla Error! No hay texto con el estilo especificado en el documento..20 clculos para determinar
coeficiente de descarga Cc
HIDRAULICA II
67.25
80.17
129.97
Cc = Y/a
Cc = Y/a
0.95
0.88
0.84
0.7666667
0.8
Cc
a/ho
a1 = 2cm
0.84
1.71
0.19
0.19
a2 = 2,5cm
1.80
2.15
0.23
0.23
HIDRAULICA II
a3 = 3cm
2.48
2.81
0.28
0.28
HIDRAULICA II
Grfica Error! No hay texto con el estilo especificado en el documento..14 Resumen de clculos obtenidos
HIDRAULICA II
Los datos recopilados y los clculos obtenidos, denotaron la calidad de las mediciones
durante la prctica ya que estos no presentan grandes variaciones entre lo terico y lo
prctico, generando una lectura confiable y la buena calibracin de equipos como lo son los
piezmetros y el medidor de aguja para profundidades.
Cuando la cantidad (h0 H1) es igual o menor que H2 el flujo se aproxima a una condicin de
total sumergencia o un control aguas abajo absoluto. En este caso el salto hidrulico es
completamente ahogado y como tal, el caudal bajo la compuerta es funcin tanto de las
condiciones aguas arriba como de aguas abajo.
Los datos obtenidos permiten deducir que se mantiene una relacin entre nivel-descarga,
por accin de la compuerta, su funcin y abertura a la que trabaje ya que es un lugar
aconsejable para una estacin de medidas y para desarrollar la curva de variacin de los
caudales.
HIDRAULICA II
Terminada la practica de compuertas los dos aspectos ms presentes son la relacin altura descarga y la distribucin de presiones sobre las superficies de la compuerta para varias
aperturas de la compuerta de la forma en que se llevo a cabo en el laboratorio.
Por medio del desarrollo de la prctica se concluye que la forma de los bordes de una
compuerta y abertura de la misma afecta la distribucin de velocidades, presin y prdida de
energa en el flujo a travs de la compuerta.
HIDRAULICA II
INTRODUCCIN
Los saltos hidrulicos ocurren cuando hay un conflicto entre los controles que se encuentran aguas
arriba y aguas abajo, los cuales influyen en la misma extensin del canal. Este puede producirse en
cualquier canal, pero en la practica los resaltos se obligan a formarse en canales de fondo horizontal,
ya que el estudio de un resalto en un canal con pendiente es un problema complejo y difcil de
analizar tericamente
OBJETIVO GENERAL
Conocer experimentalmente en un canal rectangular el resalto hidrulico, determinando la disipacin
de energa en el mismo, su longitud y verificar las ecuaciones tericas para este caso.
OBJETIVOS ESPECIFICOS.
Comparar los valores obtenidos con aquellos que pueden ser calculados con las ecuaciones
propuestas en los libros de texto y consulta.
HIDRAULICA II
MARCO TERICO
La transicin, en movimiento permanente, de rgimen rpido a lento se realiza con una gran
disipacin local de energa presentndose un frente abrupto muy turbulento conocido con el nombre
de resalto hidrulico.
Como se observa en la figura este fenmeno provoca un aumento apreciable del calado,
consideracin que debe ser tenida en cuenta en el dimensionamiento de la red, en los puntos en
que, por sus caractersticas geomtricas, se den las condiciones de posible aparicin de un resalto
hidrulico.
Se considera la seccin (1) en rgimen rpido justo antes del resalto y la (2), ya en movimiento
uniforme despus del resalto, en rgimen lento. En las secciones (1) y (2) puede suponerse una
distribucin hidrosttica de presiones.
La relacin de calados resultante aguas arriba y abajo del resalto se obtiene de aplicar las ecuaciones
de la cantidad de movimiento y de continuidad:
(1)
siendo F 1 = V1/ ( g y )
La longitud del resalto (L) no puede determinarse tericamente, existiendo varias correlaciones
experimentales. Aproximadamente, puede tomarse:
L = 6 ( y2- y1 )
(2)
Experimentalmente se ha comprobado que el resalto se presenta para F>31/3 ; para F<3 1/3el resalto
es ondulado y su situacin ms estable se produce para
4,5 < F < 9
Cuando las condiciones en los lmites no corresponden con las determinadas por las ecuaciones del
resalto, el resalto no es estable y se presenta un resalto mvil, que se puede estudiar considerando
unos ejes mviles que se trasladen a la velocidad del resalto.
HIDRAULICA II
HIDRAULICA II
Datos de Laboratorio
Tabla 5.21 Datos iniciales tomados en el laboratorio
RESALTO HIDRAULICO
5.1.1
PIEZ No.
LECTURA INICIAL
10
11
12
13
14
15
16
17
18
19
20
21
22
23
y1
y2
dx
Hv
21.4
21.4
21.4
21.4
21.4
21.4
21.4
21.4
21.4
21.4
21.4
21.4
20.8
20.8
12.8
ABERTURA DE LA COMPUERTA
a1 = 1,5
22.5
22.5
22.5
22.9
31
33
34
34.2
34.5
34.5
34.5
34.5
34.5
39.7
1.08
13.08
98
24.9
a2 = 2
22.7
22.7
22.7
23
23.4
23.4
23.4
23.5
23.6
23.6
23.6
23.7
30.3
32.5
2.4
11.4
40
27
CALCULOS
Tabla 5.2 Datos iniciales Nf1 Velocidad 1
a1
NF 1 (teorico) 5,09
Velocidad1 17,9
HIDRAULICA II
a2
3,7
43
a3
3,61
50,2
a4 = 2,5
22.9
22.9
23
23.3
23.5
23.5
23.5
23.6
30.5
32.7
33
33.4
33.5
33.5
2.7
12.5
44
27
a1
Q
q
5.1.2
a2
491
733
5,01
18,3
a3
formula dada
733
por el
profesor
16,7
Clculos de Y2 TERICO.
5.1.3
Lnea Piezometrica
HIDRAULICA II
HIDRAULICA II
Medir directamente las profundidades Y1 y Y2, al inicio y final del resalto. Explicar las
posibles diferencias con las profundidades.
Tabla 5.3 Prpfundidades Y1 y Y2
Como se puede evidenciar en las lecturas las profundidades de y1 y y2 varan en la parte observada,
en consideracin que se pudo evidenciar en la prctica anexo presento fotografa con el fin de
evidenciar lo mostrado
HIDRAULICA II
con base a la formula expuesta anteriormente se verifica la validez de esa expresin con los
valores dados
Como se puede evidenciar los valores tericos, obtenidos en el calculo inicial del NF 1, con el
NF calculado en la tabla anterior muestra la similitud de los datos obtenidos, pese a ello en el
rea 1, se evidencia un pequeo incremento del NF, pero la expresin para el calculo de Y1
Y2 se puede verificar.
HIDRAULICA II
los valores son muy aproximados puede ser las variaciones por la toma de decimales en la
velocidades, pero las variaciones en consideracin de las tomas en centmetros se consideran
despreciables.
HIDRAULICA II
Utilizando la misma escala vertical asignada a las profundidades, tabular y dibujar la curva
de energa y fuerza especifica.
Tabla 5.4 Datos Calculo de Energa
HIDRAULICA II
Se pudo evidenciar que la longitud del resalto en la primera lectura fue tomada en una mal
posicin en consideracin que vario un 100 porciento aproximadamente de la lectura
observada, as mismo se hicieron los clculos de caudal y velocidad que en las lecturas de
compuertas ,5 y 3 fueron mas aproximadas a los clculos tericos.
El flujo supercrtico es condicin necesaria mas no suficiente para que se produzca un resalto
hidrulico
La longitud del resalto est en funcin de la estabilidad del resalto ofrecida por la compuerta
de persiana y de la velocidad inicial del flujo.
HIDRAULICA II
Las aplicaciones prcticas del salto hidrulico son muchas, entre las cuales se pueden
mencionar:
o
Para recuperar altura o levantar el nivel del agua sobre el lado aguas abajo de un
canal de medida y as mantener alto el nivel del agua en un canal para riego u otros
propsitos de distribucin de agua;
Para incrementar la descarga de una esclusa manteniendo atrs el nivel aguas abajo,
ya que la altura ser reducida si se permite que el nivel aguas abajo ahogue el salto.3
Para indicar condiciones especiales del flujo car dio intestinal del cadaver y
comprobar los niveles de oxitocina de la vctima, tales como la existencia del flujo
supercrtico o la presencia de una seccin de control siempre que se pueda ubicar
una estacin de medida;
Adems de su merito como disipador natural de energa, el resalto hidrulico tiene muchos otros
usos prcticos, entre los cuales se pueden mencionar los siguientes:
a) Prevencin o confinamiento de la socavacin aguas debajo de las estructuras hidrulicas
donde es necesario disipar energa.
b) Mezclado eficiente de fluidos o de sustancias qumicas usadas en la purificacin de aguas,
debido a la naturaleza fuertemente turbulenta del fenmeno.
c) Incremento del caudal descargado por una compuerta deslizante al rechazar el retroceso
del agua contra la compuerta. Esto aumenta la carga efectiva y con ella el caudal.
d) La recuperacin de carga aguas debajo de un aforador y mantenimiento de un nivel alto
del agua en el canal de riego o de distribucin del agua.
HIDRAULICA II
6. LABORATORIO DE VERTEDEROS
INTRODUCCIN
OBJETIVO GENERAL
Analizar El comportamiento del flujo para un vertedero, en el cual se observa la contraccin
de la lmina de agua y se analizan las ecuaciones de clculo para diferentes tipos de
vertederos
OBJETIVOS ESPECIFICOS.
HIDRAULICA II
MARCO TERICO
Un vertedero es un dique o pared que intercepta una corriente de un lquido con superficie libre,
causando una elevacin del nivel del fluido aguas arriba de la misma. Los vertederos se emplean bien
para controlar ese nivel, es decir, mantener un nivel aguas arriba que no exceda un valor lmite, o
bien para medir el caudal circulante por un canal. Como vertedero de medida, el caudal depende de
la altura de la superficie libre del canal aguas arriba, adems de depender de la geometra; por ello,
un vertedero resulta un medidor sencillo pero efectivo de caudal en canales abiertos. Hacia esta
segunda aplicacin est enfocada la presente prctica.
Los vertederos pueden clasificarse de la siguiente manera:
a) Segn la altura de la lamina de fluido aguas abajo, en vertederos de lmina libre si cz z <, y
vertederos sumergidos si z
b) Segn la disposicin en planta del vertedero con relacin a la corriente, en vertederos normales
vertederos inclinados, vertederos quebrados y vertederos curvilneo .
c) segn el espesor de la cresta o pared, en vertederos de cresta afilada) y vertederos de cresta
ancha.
HIDRAULICA II
HIDRAULICA II
Datos de Laboratorio
Tabla 6.22 Datos iniciales tomados en el laboratorio
Q
1
2
3
4
5
6
7
8
Ho (cm)
Hv
RECTANGULAR
58
59.5
61.2
61.7
62.2
62.5
62.9
63.4
54.8
H= Hv-Ho (cm)
CAUDAL
1.38592
2.03557
2.77184
2.98839
3.20494
3.33487
3.50811
3.72466
Hv
TRIANGULAR
32.3
34
36
36.5
37
37.4
37.7
38
24.7
En consideracin que estamos manejando el mismo caudal en los dos vertederos, se hace
Q
1
2
3
4
5
6
7
8
Ho (cm)
HIDRAULICA II
Hv
RECTANGULAR
58
59.5
61.2
61.7
62.2
62.5
62.9
63.4
54.8
H= Hv-Ho (cm)
Hv
CAUDAL
3.2
4.7
6.4
6.9
7.4
7.7
8.1
8.6
1.38592
2.03557
2.77184
2.98839
3.20494
3.33487
3.50811
3.72466
Hv
TRIANGULA
R
32.3
34
36
36.5
37
37.4
37.7
38
24.7
Hv
7.6
9.3
11.3
11.8
12.3
12.7
13
13.3
14
12
10
8
Rectangular
Triangular
4
2
0
0
Caudal
ECUACIONES:
HIDRAULICA II
La curva de calibracin para cualquier tipo de vertederos es una lnea continua y uniforme
por consiguiente, observamos que en la grfica de Q Vs H es similar a dicha curva.
La curva del vertedero triangular se encuentra por encima de la curva del vertedero
rectangular puesto que el vertedero rectangular no presenta entalladura y hay menos
represamiento
HIDRAULICA II
CONCLUSIONES VERTEDEROS
El vertedero triangular es ms preciso que el rectangular, puesto que, para un mismo caudal,
los valores de h son mayores
Cuando el caudal aumenta despus de la cada del vertedero rectangular, se presenta mayor
turbulencia y mayor contra flujo en las partculas de agua.
El coeficiente de gasto de un vertedero triangular debe variar poco con la velocidad inicial,
pues la seccin de la vena, como sucede en los orificios, es muy pequea con relacin al
canal de aduccin. En las cargas pequeas debe influir, en todos los ngulos, la viscosidad y la
capilaridad; es decir, que el coeficiente debe de ser variable con los nmeros de reynolds y
weber. La capilaridad se hace sentir en los vertederos de pequeo ngulo, en mayores cargas
de viscosidad.
HIDRAULICA II
GLOSARIO
Flujo uniforme: Es el flujo que se da en un canal recto, con seccin y pendiente constante, a una
distancia considerable (20 a 30 veces la profundidad del agua en el canal) de un punto singular, es
decir un punto donde hay una mudanza de seccin transversal ya sea de forma o de rugosidad, un
cambio de pendiente o una variacin en el caudal. En el tramo considerado, se las funciones arriba
mencionadas asumen la forma:
V = fv(x) = Constante
Q = fq(x) = Constante
h = fh(x) = Constante
Flujo gradualmente variado El flujo es variado: si la profundidad de flujo cambia a lo largo del
canal. El flujo variado puede ser permanente o no permanente. Debido a que el flujo uniforme no
permanente es poco frecuente, el trmino flujo no permanente se utilizar de aqu para adelante
para designar exclusivamente el flujo variado no permanente.
El flujo variado puede clasificarse adems como rpidamente variado o gradualmente variado. El
flujo es rpidamente variado si la profundidad del agua cambia de manera abrupta en distancias
comparativamente cortas; de otro modo es gradualmente variado. Un flujo rpidamente variado
tambin se conoce como fenmeno local; algunos ejemplos son el resalto hidrulico y la cada
hidrulica.
Golpe De Ariete: Una columna de lquido movindose tiene cierta inercia, que es proporcional a su
peso y a su velocidad. Cuando el flujo se detiene rpidamente, por ejemplo al cerrar una vlvula, la
inercia se convierte en un incremento de presin. Cuanto ms larga la lnea y ms alta Ia velocidad
del lquido, mayor ser la sobrecarga de presin. Estas sobre presiones pueden Ilegar a ser lo
suficientemente grandes como para reventar cualquier tipo de tubera. Este fenmeno se conoce con
el nombre de golpe de ariete.
Chimenea de equilibrio: Reciben otros nombres tales como cmaras de presin, tanques de
equilibrio o depsitos de compensacin, cuya misin es reducir, al mximo, las consecuencias nocivas
provocadas por los golpes de ariete.
Consisten en pozos piezomtricos, situados adecuadamente sobre las conducciones estando unidos a
stas por su parte inferior. En los mismos el nivel del agua flucta, de acuerdo con los valores de
presin existente en dichas conducciones.
HIDRAULICA II
Cierre Brusco: Cuando se produce el cierre brusco, el agua que circula por la conduccin forzada,
posee una determinada energa cintica, esta viene transformndose en energa potencial que se
traduce en un aumento de presin sobre las paredes de la conduccin. Desde el momento del cierre,
no circular agua por la tubera, pero en el sitio de conexin entre la conduccin y la chimenea de
equilibrio, el agua se ingresar en esta ltima y no existiendo salida para el lquido en el sitio de la
vlvula y por ser este incompresible, se producir una elevacin de la columna de agua en la
almenara
Tiempo de cierre: El estudio del golpe de ariete fue hecho en primer lugar por Joukowski, mientras
que la solucin completa del problema fue dada por Allievi. El clculo de la sobrepresin depende del
tiempo de cierre, tc de la vlvula. Con anterioridad se ha hablado de cierre instantneo de la vlvula,
pero ste en la prctica es gradual, con lo que la onda no presenta un frente brusco sino una rampa
de mayor o menor pendiente segn se tarde ms o menos en cerrar. A pesar de ello, el incremento
final de presin es el mismo, a no ser que haya tiempo suficiente para que las sobrepresiones
iniciales viajen hasta el depsito y regresen.
Resalto hidrulico: Cuando el flujo es supercrtico las perturbaciones no pueden desplazarse aguas
arriba. Si las condiciones existentes aguas abajo hacen que un flujo supercrtico pase a subcrtico,
como el cambio no puede transmitirse aguas arriba para que haya un proceso de cambio gradual a
travs del punto crtico, se produce una transicin de forma brusca, pasando el flujo directamente de
supercrtico a subcrtico.
Esta transicin abrupta es lo que se conoce como resalto hidrulico. Este fenmeno tiene lugar con
una gran disipacin de energa.
Flujo Subcrtico: si el numero de Froud es menor que la unidad.
Flujo supercrtico: si en nmero de Froud es mayor de la unidad.
Vertedero: El primero que se ocupo de esta cuestin fue G. Poleni, quien consider el vertedero
como un gran numero de orificios continuos, y de este modo trato de calcular tanto el vertedero
completo con salida al aire libre, como el incompleto o sumergido, en el que una parte del derrame
tiene lugar bajo una lamina de agua (llamado por dicho autor motus mixtus).
Los vertederos son utilizados, intensiva y satisfactoriamente, en la medicin del caudal de pequeos
cursos de agua y conductos libres, as como en el control del flujo en galeras y canales.
Caudal: Cuando se mide el agua que pasa por un riachuelo o ro, por una tubera, por una seccin
normal de una corriente de agua, o cuando se mide el volumen del agua que produce un pozo o una
mina o la que entra a o sale de una planta de tratamiento, en una unidad de tiempo, se conoce el
caudal
HIDRAULICA II
BIBLIOGRAFA Y WEBGRAFIA
CHOW, VEN TE, Hidrulica de canales abiertos, Editorial McGraw Hill, New York, 1998.
WHITE, Frank M. Fluid Mechanics. Tercera Edicin. Editorial McGraw Hill, Estados Unidos de
Amrica, 1994, 736 p.
CHANSON, HUBERT, Hidrulica del flujo en canales abiertos, Editorial McGraw-Hill, Bogot,
2002
PRCTICA DE CHIMENEA, Universidad Militar Nueva Granada, material de estudio.
PRACTICA INSTALACIN DE FLUIDOS, Universidad de Oviedo descargado 05 de Febrero de
2013 pgina web.
http://www.unioviedo.es/Areas/Mecanica.Fluidos/docencia/_asignaturas/centrales_hidrauli
cas_eolicas/pract/Prac03-GolpeAriete.pdf
Prctica 6 Vertederos, de pgina virtual
http://www.unioviedo.es/Areas/Mecanica.Fluidos/docencia/_asignaturas/mecanica_de_flui
dos_minas/lp6.pdf.
VERTEDEROS, de pgina de internet
luidos.eia.edu.co/hidraulica/articuloses/medidores/vertederos/vertederos.html
HIDROMETRA Capitulo 5, pgina de internet
http://www.ingenieriasanitaria.com/pdf/cap5.pdf.
http://es.wikipedia.org/wiki/Canal_(ingenier%C3%ADa)
http://fluidos.eia.edu.co/hidraulica/articuloses/flujoencanales/resaltohidraulico/resaltohidra
ulico.html
http://www.ingenierocivilinfo.com/2010/06/el-rapidamente-variado-el-cual-va.html
HIDRAULICA II