Measuring Task Clamp-On Flow


Flow measurement of a fluid at pressures above 250 bar Measurement at
and at temperatures over 100°C in a stainless steel pipe High Pressure
(Ø 48.4 mm, wall 9.2 mm)

Instruments Used Customer


FLUXUS®ADM 8027-S with transducers
Q4N-Ex and VARIOFIX fixation system
Advantages
• Precise, non-invasive measurement
• Not disturbed by deposits
• No process interruption for maintenance or installation Degussa,
production site Marl
Selling Points
• Significant savings in comparison to in-line systems due to the high
pressure levels involved
• Reliable measuring at the output of the high pressure pump
• High precision measurement due to statistical signal analysis
• ATEX certification for operation in explosion hazard areas

Description
In a production facility at the degussa plant in the Chemical Park Marl,
precise reactant metering during the synthesis of an alcohol is excep-
tionally important for the process management.
At the measuring point, the fluid is conveyed with a high pressure pump at
> 250 bar overpressure and a mass flow rate of up to 500 kg/h.
In the past, the flow measurement was realized at the inlet of the high
pressure pump with a Coriolis flowmeter. The strong pressure fluctuations
caused by the pump resulted in significant measuring irregularities.
In addition, the formation of crystalline deposits inside the pipe made
regular maintenance necessary.
FLUXUS® ADM 8027 is a clamp-on flowmeter. No cutting into the pipe
system is needed for installation, the ultrasonic flow transducers must
simply mounted onto the outer wall of the pipe. The measurement is not
pressure sensitive. In this case, this means that the flow measurement
can be made at the outlet of the high pressure pump without incurring any
additional costs.
As the measurement takes place in an explosion hazard area, the ATEX
certified FLUXUS® ADM 8027-S with Q4N-Ex-transducers is used in this
special application.
The pilot project has been running continuously and trouble-free since
August of 2003. Up to now, no maintenance has been necessary.
The FLUXUS® ADM 8027-S had already been successfully tested by the
degussa subsidiary for flow measurement of process gas at P > 250 bar
and in the sump circuit at P > 250 bar and T > 100 °C.

Copying and distribution allowed only with the written permission of FLEXIM GmbH. The copyright of this report, its components, its content and its
pictures is owned by FLEXIM or by third parties. All rights reserved. The aim of this application report is solely to give general information about the
application. It gives no insurance about the suitability for a specific purpose.
AR-200511-degussa-EN.doc, 07/12/2005, Page 1 of 1

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963

Potrebbero piacerti anche