Sei sulla pagina 1di 3

NO 5 AND 7 JALAN 35/10A,

TAMAN PERINDUSTRIAN IKS,


IKS MUKIM BATU CAVES,
68100 KUALA LUMPUR, MALAYSIA.
URL: http://www.greenseal.com.my

Tel: 603-61882298
Fax: 603-61861298
E-mail : sales@greenseal.com.my

Greenseal Product (M) Sdn Bhd is an ISO qualified company: AR 2748. The Greenseal
Products Quality System is compliance with MS ISO 9001: 2008.
GREENSEAL FLEXI 201 CEMENTITIOUS WATERPROOFING METHOD STATEMENT
FOR PLANTER BOX / LANDSCAPE AREA / GARDEN TERRACE / AIR-COND LATCH /
BALCONY / WATER TANK / COVERED WATER TANK AREA

Description:
Greenseal Flexi 201 is a flexible cement based of 2 components polymer modified
waterproof coating. It is suitable to be applied to concrete and mortar to prevent water
infiltration as to fill and seal pores and voids crack and hair line of all substrates and yet
provides a breathable coating which allows water vapour transmission. It acts as a
protective layer against aggressive gas such as carbon dioxide, frost and thawing salts.

1.

Surface Preparation

Main contractor is to power float or steel trowelled the surface to receive the
waterproofing material.

All surfaces to be treated with Greenseal product must be thoroughly inspected, the
concrete surface must be clean and free from oil, Grease, paint, loose dust, mud
and laitance.

Horizontal surfaces should not have curing agents or hardeners applied prior to the
Greenseal application.

Honeycombs should be hacked off to expose the concrete.

All chipping and loose particles should be removed, clean surface with water before
repairing.

All the hacked off areas with Greenseal Injection Grout.

New concrete must be at least three days old before it should be treated.

2.

Angle Fillet

At all junctions between slabs and walls, do an angle fillet of 25mm X 25mm with
Greenseal Injection Grout.

Mix 3 parts of Greenseal Injection Grout to 1 part water to mix thoroughly to a


mortar consistently and applied with a trowel to form an angle fillet.

3.

Outlet and Pipe Penetration

Around all outlets hacked around the pipe sleeve to make a V groove joint
surrounding the outlets and pipes to a depth of 25 mm.

Wash thoroughly this hacked off areas to expose the clean concrete surfaces
between outlet pipe and concrete.

Mix Geenseal Injection Grout 2 parts to 1 part of water in a container and stirred
thoroughly for at least 3 minutes until the mixture become a thick consistency slurry
and pour the mixture or grout into the hacked off V grooved and level to concrete
level.

4.

Mixing

GS Flexi 201 is supplied in 2 components, to generate consistent slurry, pour the


liquid component into a pail following by adding in the powder component gradually
to the liquid. In the meantime, use a stirrer to stir the mixture until the mixture is free
from lumps. Take note of the consistency of the slurry. The consistency of the slurry
can be altered by reducing or adding in powder component.

5.

No water or other material should be added in the mixture.

Application Procedures

Apply GS Flexi 201 with a stiff brush or spray onto the prepared surface
approximately 1.0 kg/m2 per coat 2 coats are required.

Interval of each coat should be 1-2 hours minimum. To avoid pin holes and ensure
full coverage, apply each brush coat at different direction.

Be caution. No standing water or excessive water shall be remained on the


substrate that to be applied with GS Flexi 201.

For large space, spray is recommended by using a worm-gear type of spray


equipment.

For best result, apply GS Flexi 201 under shaded shelter to prevent rapid drying of
the coating.

6.

Curing

The freshly applied GS Flexi 201 shall be protected from direct rain, dirt, oil, grease
or other loose particle for at least 12 hours.

It is foot trafficable after 24 hours and resistant to light mechanical stress after 3
days. Permanent water pressure resistance shall be achieved after a full hardening
of 14 days.

Clean tools and equipment immediately with clean water before the waterproofing
sets. Hardened material can only be removed mechanically.

7.

Screed and tiling works

Any plastering or screed to be applied on top of GS Flexi 201 shall have the advice
of Greenseal Product Malaysia Sdn. Bhd.

For tiling works to be laid on top of GS Flexi 201 at shower wall area, the Flexi 201
membrane must be at least 3 days old before tiling. Ensure finish coat has been
applied, and it must be ensured that the surface is free from dust, efflorescence,
and clean, dry and dust/contamination-free prior to tiling. The surfaces of Flexi 201
should be primed with a suitable primer such as GREENSEAL SBR 701 BONDING
AGENT and allowed to dry before tiling.

8.

Protection Gear

General products are alkaline materials and prolonged contact with the skin is best
avoided as it could give rise to irritation. To minimize such risks, we recommend the
use of rubber gloves when handling or sprinkling our products.

Greenseal Products (M) Sdn. Bhd.


Lot 5 & 7, Jalan 35/10A, Taman Perindustrian IKS
Mukim Batu Caves, 68100 Kuala Lumpur, Malaysia
Tel : 603-6188 2298 Fax : 603-6186 1298
E-mail : sales@greenseal.com.my
URL: http://www.greenseal.com.my
3