TRANSFORMERS
IS:10028 (Part 2 & 3)
Page 5 of 11
CIRCUIT BREAKERS
IS 14658-1999
-High Voltage Alternating Current Circuit Breakers - Guide for
Short-circuit and Switching Test Procedures for Metal-enclosed and Dead Tank
Circuit Breakers
IS-13118-1991
- High Voltage Alternating Current Circuit Breakers
IEC-62271-100
- High Voltage Alternating Current Circuit Breakers
IEC-60427
- Synthetic Testing of High Voltage alternating current
circuit Breakers.
IEC-61264
- Pressurised Hollow Column Insulators
IEC-60376
- Specification and Acceptance of New Sulphur
Hexafloride
IS-5621/ IEC-233
-Hollow column insulators
CURRENT TRANSFORMERS, VOLTAGE TRANSFORMERS
IS-2705- (P1 to P4)
- Current Transformers.
IS:3156- (P1 to P4)
- Voltage Transformers.
IS-4379
- Identification of the Contents of Industrial Gas Cylinders
IS-4201
-Application guide for current Transformer.
IEC-60044-1
- Current transformers.
IEC-60044-2
- Voltage Transformers.
IEC-60044-4
- Instrument Transformers: Measurement of Partial
Discharges
IS-2099
- Bushings for Alternating Voltages above 1000V.
IS-335
-New insulating oil for transformer and
switchgear.
IEC-60137
SURGE ARRESTERS
IS-3070 (PART2)
IS-4004
IEC-60099-4
IEC-60099-5
Page 6 of 11
DISCONNECTING SWITCHES
IEC-60129
- Alternating Current Disconnectors (Isolators) and
switches
IEC-1129
- Alternating Current Earthing Switches Induced
switching.
IS-9921
- Alternating Current Disconnectors (Isolators) and
switches.
IS: 2544-1973
:Porcelain Post insulators for systems with nominal
greater than 1000 Volts.
IEC-60265 (Part 1 & Part 2) - High Voltage switches
Earthing
Current
Earthing
voltages
Page 7 of 11
Page 8 of 11
IEC-60183
- Guide to the Selection of High Voltage Cables.
IEC-60189 (P1 to P7) - Low frequency cables and wires with PVC insulation and PVC
sheath.
IEC-60227 (P1 to P7) - Polyvinyl Chloride insulated cables of rated voltages up to and
including 450/750V.
IEC-60228
- Conductors of insulated cables
IEC-60230
- Impulse tests on cables and their accessories.
IEC-60287 (P1 to P3) - Calculation of the continuous current rating of cables (100% load
factor).
IEC-60304
- Standard colours for insulation for low frequency cables and
wires.
IEC 60840 (1988)
-Test for power cables with extruded insulation
IEC-60331
- Fire resisting characteristics of Electric cables.
IEC-60332 (P1 to P3) - Tests on electric cables under fire conditions.
IEC-754 (P1 and P2) - Tests on gases evolved during combustion of electric cables.
PAINTING
IS-6005
ANSI-Z551
Page 9 of 11
LT SWITCHGEAR
IS:8623 (Part-I)
Specification for low voltage switchgear and control gear
assemblies
IS:3231
Electrical relays for power system protection
IS:5578
Guide for Marking of insulated conductors of apparatus terminals
IS:13703 (part 1 and 2)- Low voltage fuses for voltage not exceeding 1000V AC or
1500V DC
IS:6005
Code of practice of phosphating iron and steel
IS:5082
Wrought Aluminum and Aluminum alloys for electrical purposes
Page 10 of 11
Electrical Installation
(1) IS:1293
3 pin plug
(2) IS:371
Two to three ceiling roses
(3) IS:3854
Switches for domestic and similar purposes
(4) IS:5216
Guide for safety procedures and practices in electrical
work.
(5) IS:732
Code of practice for electrical wiring installation
(system voltage not exceeding 650 Volts.)
(6) IS:3043
Code of practice for earthing.
(7) IS:3646
Code of practice of interior illumination part II & III.
(8) IS:1944
Code of practice for lighting of public through fares.
(9) IS:5571
Guide for selection of electrical equipment for hazardous areas.
(10) IS:800
Code of practice for use of structural steel in general building
construction.
(11) IS:2633
Methods of Testing uniformity of coating on zinc coated articles.
(12) IS:6005
Code of practice for phosphating iron and steel.
(13)
INDIAN ELECTRICITY ACT
(14)
INDIAN ELECTRICITY RULES
The design, manufacture and performance of the equipment provided under this
specification shall comply with the standards and rules given in the Annexure-I Unless
other wise specified the equipment shall conform to the latest applicable Indian
Standards/ IEC.
All the Indian manufacturers shall supply equipment as per IS and the Foreign
manufacturers shall follow relevant IEC.
Page 11 of 11
SECTION :B-V
CLIMATIC CONDITIONS AND SYSTEM PARAMETERS
1.1
The equipment covered under this specification are for outdoor installation and
heavily polluted atmospheric condition prevailing at site.
1.2
a)
TEMPERATURE:
The reference ambient temperature be taken as 43.3C as per IS-9676.
i)
Max. daily ambient air temp.
:
50C
ii)
Max. daily average temp.
:
40C
b)
RELATIVE HUMIDITY :
i)
Maximum
ii)
Minimum
iii)
Average Annual Rainfall
iv)
Average number of rain days
Per annum
v)
Average number of thunder from
Days per annum
vi)
Altitude
vii)
Wind pressure up to 30 Mtr.
Elevation as per IS-875-1975
1.3
1.4
:
:
:
100%
10%
750 mm
50
:
:
40
300 mtrs.
195 kg/Sq.Mtr.
The atmosphere is generally laden with mild acid and dust in suspension during
the dry months and is subject to fog in cold months. Heavy lightning strokes are
sometimes encountered in the area during the rainy months. The creepage
distance of the bushing for outdoor circuit breaker should not be less than 25
mm/KV for heavily polluted atmospheric conditions.
All the equipment shall be designed to withstand seismic forces corresponding to
an acceleration of 0.3g.
Page 1 of 2
Nominal Voltage
220 KV
66 KV
245
72.5
1050
325
460
140
40
31.5
Page 2 of 2