DISOMATOpus

System Manual

BV-H2310GB

Service
Quality and reliability form the basis for Schencks corporate philosophy all over the world. Thats why we offer
you an extensive service strategy starting with our stringent quality control through assembly and
commissioning right down to all-round support. Were always there for you.
Free Helpdesk (Monday through Friday from at least 8 oclock to 5 p.m. CET)
Service specialists are available to you in every department during our normal office hours for analying
problems and malfunctions.
Heavy Industry
Building materials, mining, foundry,
steel and cement
T +49 61 51 - 32 31 38
F +49 61 51 - 32 32 70
heavy@schenckprocess.com

Vibrating & Screening


Technology
T +49 61 51 - 32 35 25
F +49 61 51 - 32 30 96
vibrating@schenckprocess.com

Light Industry
Chemistry, plastics, foodstuffs and pharmaceuticals
T +49 61 51 - 32 25 71
F +49 61 51 - 32 26 68
light@schenckprocess.com
Transport Automation
All industries with logistics processes and trains
T +49 61 51 - 32 24 48
F +49 61 51 - 32 13 69
transport@schenckprocess.com
Spare Parts & Components
T +49 61 51 - 32 17 58
F +49 61 51 - 32 36 32
spares@schenckprocess.com
components@schenckprocess.com
Individual phone consulting (fee required)
(Monday through Friday from at least 8 oclock to 5 p.m. CET)
Do you want one of our service specialists to give you phone support in commissioning your system or on-line
diagnosis / system optimisation? Were there for you. Schedule an appointment with us whenever you need it.
Free 24 h Customer Service Hotline
24h Emergency-Hotline:

+49 172 650 17 00


+49 171 225 11 95

Transport Automation and


Static Weighing Equipment
Heavy Industry, Light Industry
excluding Static Weighing
Equipment

Copyright 2006
Schenck Process GmbH
Pallaswiesenstrae 100, 64293 Darmstadt, Germany
www.schenckprocess.com
All rights reserved. Any reproduction of this documentation, regardless of method, without prior permission by
Schenck Process GmbH in writing, even by excerpt, is prohibited.
Subject to change without prior notice.

Contents
1

Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Housing dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3
3.1
3.1.1
3.2
3.3
3.4
3.5
3.6

Connection of the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6


Load cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Preparing the load cell plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Digital inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Impulse output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Relay outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Note for connecting the serial interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installing the legal-for-trade memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Bus coupling modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

4.1
4.2
4.3

Profibus VPB 020 coupling module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14


Fieldbus monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
VCB 020 device net coupling module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Instructions for operating the . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11

Serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DISOMAT Opus / Satus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Parametrization and calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Function Variant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Loading language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Backup and Restore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Loading flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Product Service Internet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Reading out the legal-for-trade memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Editing language. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Calibration / signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

I1

- Reserved for users notes -

I2

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Safety notes

The Manual
This manual describes the DISOMAT Opus weighing indicator, designated as
DISOMAT or the system below.
It explains:
How it works
The connection diagrams
The accessories
for the VKG 20700 and VKG 20701 system version.
This manual is valid from firmware version VWW 20700-01
You can find additional information (such as other details on the fieldbus
couplings) in the following manuals for the DISOMAT system.
n
n

The DISOMAT Opus Operation Manual BV-H 2313


Data communication DISOMAT, Bplus, DISOMAT Opus, Disobox
BV-H 2316

Safety notes
Using for the Intended Purpose
The measuring system with its connected mechanical components is only
intended for weighing and control applications directly associated with them. Any
use beyond this is deemed as not as originally intended.

Sources of danger
The measuring system does not generate any hazards during the weighing
process if the system is properly installed and put into service.
Using the measuring system might be dangerous if the system takes on control
functions or when the material weighed is transported. Potential sources of danger
would then be add-on equipment that the material weighed is transported in or
metered through. In such cases, the measuring system may cause residual
hazards if untrained staff uses or operates it incorrectly.
This measuring system may be a component of a more complex system. The
system operator bears the full responsibility for operating safety.

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

Safety notes

Labelling residual hazards


This symbol indicates hazards that could cause personal injury or even death in
extreme cases.
This symbol indicates hazards that could cause property damage to the measuring
system or other system components.

Personnel
Only trained technical staff may prepare, assemble, start up, operate, service or
maintain the measuring system.
Everyone doing work on the measuring system should read the safety instructions
and be aware of and follow the parts of the service manual applicable to them.
The operator should use the service manual to instruct the operating personnel to
comply with all regulations and instructions.

Changing parameters
Parameters dictate how the measuring system functions. Only persons familiar
with the systems function should change the parameters (such as persons trained
by SCHENCK). Incorrect parameter settings may be dangerous to persons or
cause property damage with control systems connected to the system. They may
also greatly disturb the weighing process.

Password:
Parameters are protected by password from being changed without authorization.
The measuring system operator should use the password in a responsible fashion.

Acknowledging fault indications


Fault indications may only be acknowledged after the cause of the fault has been
rectified.
Before acknowledging a fault, please ensure that connected peripheral units are
functioning properly. Especially connected control systems should be in a defined
and safe state.

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Safety notes

Service and maintenance


Please read all of the warning signs on the scale.
Please shut off the measuring system before working on the mechanical
equipment or peripheral units (particularly control systems). Take appropriate
action to ensure that the measuring system cannot be inadvertently restarted.
Electrical systems may only be worked on when they are dead (pull the plug).

Moisture and humidity


All parts of the scale (particularly the electrical components) have to be protected
from moisture and humidity when the casing is open (for instance, during service
and maintenance work). Otherwise, please observe the protection class of the
casings.

Design modifications
If you make design modifications on the measuring system or add components
that SCHENCK does not supply, SCHENCK shall not accept any liability or
warranty. This especially applies to modifications that may have an impact on
operational safety.

Replacing parts
Only use original SCHENCK spare parts if parts have to be replaced during
repairs. If other spare parts are used, the warranty shall be rendered invalid.

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

Housing dimensions

Housing dimensions
The DISOMAT Opus is a complete weighing indicator for a variety of applications.
The VKG 20700 / 20710 stainless steel protection class IP65 casing is designed
for table installation. It can also be mounted on the wall after rotating the lid
(downward cable outlet).
Figure 1 shows the system dimensions

Fig.: 1

Figure 2 shows the drilling pattern for wall mounting. The required mounting
hardware is included in the system.

Fig. 2:

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Housing dimensions
Figure 3 shows the position of the connecting terminals.

Fig. 3: The dimensions of the VEG 20700 top-hat rail machine

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

Connection of the equipment

Connection of the equipment


Figure 4 shows the situation of the connecting terminals

Fig. 4

1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:

Voltage supply (mains voltage)


Serial interface
S1
(RS 232)
Serial interface
S2
(RS 232)
Serial interface
S3
(RS 485)
Nanmur input/pulse output
Digital outputs
Digital inputs
Analog output
Load cell connection
Network connection (Ethernet)
USB cable
Extension connectors for field bus modules

Note:
Some of the interfaces are not equipped in some system designs.

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Connection of the equipment

Fig. 5:

Screened lines (load cell connection, the serial interfaces are stripped in the
system and strain relieved on the rail with the attached clamps).

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

Connection of the equipment

Fig. 6:

System block:
1
PWRST (green):
The supply voltage is applied
2
Idle: (yellow)
Display of system load
Longer ON period = less load
3
Fault (red):
Error message
5
Sys-CL (yellow):
System clock, flashes in normal operation
4, 6 Diag (green/red): No function
Network block:
1
Link (green):
2
DX (yellow):
3
100 (red):

Ethernet has connection


Full duplex
100 M baud (otherwise 10 M baud)

BV-H2310GB / 0628

System Manual DISOMATOpus


SCHENCK PROCESS

Connection of the equipment

3.1

3.1 Load cells

Load cells

Fig. 7: Schenck RT-weighing cell connection

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

3.1 Load cells

Connection of the equipment


If the scale design provides the ground connection for a load cell body, it is not
necessary to connect it via PAS.
It is not necessary to contact the cable screen on terminal 50 of the
interconnecting control with load cells where the shield of the connecting channel
is connected to the load cell body (such as Schenck VBB).
In this case, the shield is contacted via the load cell body and PAS or earth.
Please refer to the manufacturers documentation for details on connecting more
load cells.

3.1.1 Preparing the load cell plug


The memory chip for adjusting and calibrating data has to be mounted before
connecting the load cell cable.
The chip is enclosed in the delivery.
Connection 1 of the chip is removed (refer to the Figure; the flat side is on top).
It is connected on pins 2 and 3 of the plug as shown (refer to the Figure; the
flat side is on top)
The parameters are write-protected with a jumper between pins 1 and 3.

Fig. 8

Fig. 9

10

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Connection of the equipment

3.2

3.3 Impulse output

Digital inputs

Fig. 11: Inputs connection diagram

3.3

Impulse output

Fig. 10: Impulse output connection diagram

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

11

3.5 Note for connecting the serial interface

3.4

Connection of the equipment

Relay outputs

Fig.12 : Relay outputs connection diagram

3.5

Note for connecting the serial interface


S3 (RS485)
Contacts 1-3 and 2-4 are jumpered for operation as a RS485-2 wire interface. An
additional 120 Ohm bus termination resistor should be mounted for the last bus
devices.

Fig. 13: Connection diagram S3 as RS485-2

If the interface is operated in the 4-wire mode, the terminal resistor comes onto the
reception side (PIN 3-4).

12

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Connection of the equipment

3.6

3.6 Installing the legal-for-trade memory

Installing the legal-for-trade memory


Please do the following for subsequent installation of a legal-for-trade memory:
n Attach the module on the XES plug. The modules plug points to the plugs of
the mainboard (refer to the photo).
n It makes sense to safeguard the module with some hot glue.
n If a fieldbus card is used simultaneously with the legal-for-trade memory, the
LEDs on the bus card will push the memory board aside a little. This is safe.

Fig. 14:

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

13

4.1 Profibus VPB 020 coupling module

Bus coupling modules

Bus coupling modules


The VPB 020, VCB 020 and VSS 021 bus coupling modules are fastened to the
CPU board with 3 screws each (component side upwards). It is electrically
connected via the ribbon cable. All of the parts needed for subsequent mounting
are attached to the coupling module.

4.1

Profibus VPB 020 coupling module


This module can be attached to the main DISOMAT board to provide an interface
to the PROFIBUS-DP. This module is designed and certified as per DIN 19245 or
Part 2 of EN 50170 and has automatic baudrate identification to 12 Mbit/s (12
Mbaud).
The circuit board has two connections for connecting the bus. You can use both
the XP3 plug (clamps) and the XP1 (HD-9 pole) in the DISOMAT.
Please remember that the first and last unit on the PROFIBUS-DP system have to
have a bus termination. You can do this by setting jumpers W150, W151 and
W152 to 1-2.
Caution: All jumpers have to be in the same position.
Pin assignment
XP1

XP3

Pin No.

Pin No.

3
8
5
6
1

1
2
3
4
5

RxD/TxD-P*
RxD/TxD-N**
DGND
VP
screen***

* : = -P = B
** : -N = A
*** : The screen should not be placed on the plug, but on the
cable clamp.
The HI20 LEDs indicate proper bus operation (transmitting and receiving)

14

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Bus coupling modules

4.1 Profibus VPB 020 coupling module

Fig. 15: Position of connections and jumpers VPB 020

Caution!
W100 has to be in position 2-3 to operate with the DISOMAT.
Note:
If the last slave that is actively terminated is removed from the bus, this may cause
the entire bus to malfunction. This fault occurs particularly often when using
alternating scales. This problem can be prevented by using a separate active bus
termination such as the one offered by Siemens under order number 6ES7
972-0DA00-0AA0. You can also purchase the bus termination from Schenck
Process under material number V014298.B01.
External wiring
Instructions for setting up external wiring and preventing
malfunctions can be found in the Profibus
Guideline of the Profibus User Organization (PNO),
order number 2.111.
Please refer to the BV-H 2316 DISOMAT, Bplus, DISOMAT Opus, DISOBOX,
Data Communication for more details on the Profibus, particularly for setting up
transmitted data.
Projecting aids (drawings, rules)
Part 3 of the Profibus standard DIN 19245 defines a system master data file while
the matching Profibus planning file (.gsd) is available on storage medium. You can
also download it via Internet from the Schenck Process product page under
http://www.schenckprocess.com under Products/Services and Downloads.

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

15

4.3 VCB 020 device net coupling module

4.2

Bus coupling modules

Fieldbus monitoring
Fieldbus monitoring (Profibus DP)
Since output contacts are set and feed unit drives can be triggered via the fieldbus
interface, any breakdown in communication has to be identified and the
corresponding outputs have to be put into the safe state. Monitoring is active when
the set timeout time 0 and a fieldbus card is connected.
If communication to a fieldbus master breaks down, any charging in process is
stopped after the time-out time and a fault is indicated. After resuming
communication, the fault indication is automatically cleared.

4.3

VCB 020 device net coupling module


This module can be attached to DISOMATs to interface it to the DeviceNet.
The VCB 020 card has two bus connecting plugs. Both XC1 and XC3 plugs can be
used in DISOMAT.

Pin No..
1
2
3
4
5

0V
CANShielding (please put it on the cable inlet and not on the
XC plug)
CAN+
+24V

The bus address is set via software.


Please remember that the first and last unit on the CAN bus have to have a bus
termination. Set the jumper
W160 to 1-2.
W100 has to be on pos 2-3 to operate on the DISOMAT.
You can find more details on Devicenet (particularly on setting up the data
transmitted) in the manual DISOMAT, Bplus, DISOMAT Opus, DISOBOX, Data
Communication BV-H 2316.

16

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Bus coupling modules

4.3 VCB 020 device net coupling module

Fig. 16: Position of connectors and


jumpers VCB 020

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

17

4.3 VCB 020 device net coupling module

Instructions for operating the

Instructions for operating the


DISOPLAN DISOBOX
The DISOPLAN PC program is available for conveniently configuring and
parametering the DISOMAT family scales
The instruments that can be interfaced now are:
DISOMAT Opus
DISOMAT Satus
DISOBOX
Acceptable operating systems are:
n WINDOWS XP
n WINDOWS 2000
You can do the following with DISOPLAN:
n Assign subscriber addresses to the serial bus
n Configure interfaced instruments
n Display group and channel weights and their status (only with DISOBOX )
n Edit the language files and load into DISOMAT
n Read out the entire system configuration (back-up) and store in the PC
n Load stored data into a DISOMAT (restore) for fast substitute system set-up.
NOTE:
Access to the DISOPLAN functions is administered via license levels. They range
from the standard operator to the instrument developer. This is the reason why
some of the functions shown in this manual may not be visible or accessible in
other installations.
DISOPLAN installation is self-explanatory.

18

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Instructions for operating the

5.1

5.1 Serial connection

Serial connection
DISOMAT Satus has an explicit diagnosis interface to connect DISOPLAN. The
PC is connected via a zero modem cable.
Der Anschluss der DISOBOX verwendet Schnittstelle S1 im Gert. Am
einfachsten wird das Schenck-Kabel V052410.B01 verwendet. Alternativ kann
auch ein Kabel nach den Plnen im Systemhanbdbuch BV-H 2251 angefertigt
werden. Sofern die Schnittstelle S1 nicht von anderen Gerten belegt ist, ist der
Anschluss von DISOPLAN jederzeit mglich. Ist die Schnittstelle anderweitig
belegt, z.B. durch eine Zweitanzeige, muss die DISOBOX aus- und eingeschaltet
werden. Der Start des Einrichtbetriebs mit DISOPLAN ist innerhalb der ersten
Minute nach dem Einschalten mglich. Nach dem Beendigen von DISOPLAN wird
das Gert erneut aus- und eingeschaltet und nimmt nach einer Minute den
normalen Betrieb auf.
The same mechanism is also available with DISOMAT Opus. You can activate
setting-up mode at any time in the 5C Start DISOPLAN menu item.
All systems can also be configured via Ethernet (the VET 020 option card has to
be installed on DISOBOX). This allows access to the system at any time, but the
configuration of the PC used has to allow access to the systems network address.
The following figure shows the start screen of DISOPLAN:

Then select the interface used via the Settings/ Interface menu item:

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

19

5.1 Serial connection

Instructions for operating the

The interface parameters are fixed and DISOPLAN sets them correctly.
You can also configure a TCP interface for the appropriate instruments (see
above). Select the Fixed Address option. The IP address has to be set locally on
the instrument or the instrument default address has to be used (refer to the
particular System Manual).
Then open the interface via the Communication menu item.

20

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Instructions for operating the

5.1 Serial connection

If you select Serial Connection, you can assign bus addresses (MODBUS) for
interfaced instruments with the serial number on the outside of the instrument.
Then the Scan Bus button is used to search the interface for connected
instruments The following figure shows an example where a DISOBOX was found
on the bus.

Other detected instrument models are shown in the window with other symbols.
You either click the symbol twice to configure an instrument or it branches to the
appropriate instrument via Show Selection.

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

21

5.2 DISOMAT Opus / Satus

5.2

Instructions for operating the

DISOMAT Opus / Satus


You come to the following overview fields when you start configuring a DISOMAT
Opus Satus from the DISOPLAN start screen. From there you can directly call up
the most important functions:

Abb. 17:

22

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Instructions for operating the

5.3

5.3 Parametrization and calibration

Parametrization and calibration


You can use the settings symbol to get to instrument configuration. When you load
the data, it shows the internal menu tree of DISOMAT as shown.
It offers all instrument parameters and functions in a transparent fashion for editing
and executing. Since all of the functions have been explained in the BV-H2313
Operating Manual, we shall not go into them in detail here.

Fig. 18:

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

23

5.5 Loading language

5.4

Instructions for operating the

Function Variant
You can use this menu item to activate and parameter predefined configurations
for the DISOMAT. Please refer to the BV-H2313 Operating Manual for details.

Abb. 19:

5.5

Loading language
You can load a predefined language file into DISOMAT under language.
You can load it into the instrument after selecting the file (generally db_texte.lng)
and selecting a language (Spanish in this example).. Then activate this language
under National Settings / Language Loaded.

Fig. 20:

24

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Instructions for operating the

5.6

5.9 Reading out the legal-for-trade memory

Backup and Restore


The items in the Data Security menu are only available at the present if it has
serial coupling to DISOMAT.
They are:
Data security: reading out the program and data from DISOBOX into a back-up
file
Data restoration: restoring data from the back-up file into the instrument

5.7

Loading flash
Loading a new software version. Loading is registered in the instrument (logfile)

5.8

Product Service Internet


The code issued under Information / Product Service Internet enables you to
download current information on DISOBOX such as software updates or the latest
manuals.

5.9

Reading out the legal-for-trade memory


You can read out the internal legal-for-trade memory of DISOMAT in the Actions /
Read Legal-for-trade Memory menu item..

Fig. 21:

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

25

5.11 Control unit

Instructions for operating the


You can use Information to call up data on the oldest / most recent memory input
and its assignment. Then you can read the data into a new file or attach it to an
existing file. We recommend attaching files especially with greater amounts of data
since reading out a full legal-for trade memory can take several hours.
The data are filed in a text file and they can be opened with data processing
programs or also be imported into Excel.

5.10 Editing language


You can not only load prepared language files into DISOMAT as described above.
You can also change them and create new languages (under the Actions / Edit
Language menu item).

5.11 Control unit


You can start a window in the Actions / Control Unit item that shows the entire
display of DISOMAT. This allows you to operate the instrument via the built-in
keyboard. This function is especially useful when DISOPLAN is operated via
modem or network and the instrument is not in view.

26

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Calibration / signs

5.11 Control unit

Calibration / signs
The legal-for-trade parameters and the results of adjustment are stored in the
scale connector that is called a dongle. The benefit is the fact that it does not have
to be adjusted again after exchanging or changing the DISOMAT. Manipulating the
dongle causes a loss of adjustment.

Fig. 22:

Please do the following for parametring and adjustment:


1.
2.
3.
4.
5.
6.
7.
8.
9.

Switch the mains voltage off


Open the system and the dongle casing by unhinging on the side with a
screw driver
Remove the wire jumper between clips 1 and 3 of the attaching plug
(refer to the photograph)
Do calibration as described in the service manual.
The relevant data are write proteted when a wire jumper is set between
clips 1 and 3.
Clip the dongles plastic casing components together.
If it is calibrated, tape the calibration lead over the casing seam.
The instrument casing is not locked
A stamping plate is placed on the outside of the casing - preferably on the
front side above the keyboard - that has the following data:
- Min
- Max
-e
- The accuracy class of the scale (III or IIII)
- Its licence number D06-09-xx
- CEyy where yy is the last two digits of the year it was built (for instance,
CE06 was built in 2006)
- The easist way to make the plate is with Schencks DISOFORM software
and the figure below shows a sample print-out.

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

27

5.11 Control unit

Calibration / signs

Fig. 23

10. If the stamping plate is not made of material that is destroyed when removed,
it has to be protected by an adhesive stamp.
11. Also mount the EC calibration symbol (the green M).

28

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS

Technical Data

5.11 Control unit

Technical Data

Display

LCD 1 line 20 characters. Character height 12 mm , backlight

Keyboard

21 flexible membrane keys 6 keys

Supply voltage Typ VKG

85-250 VAC (-15/+10%), 50-60Hz, max. 10 VA

Supply voltage Typ VEG

18 - 36 VDC

Housing

Stainless steel, 1.4301, deep drawn, IP 65 ( NEMA XX )

Temperature range

Service temperature: -30 to +60 C ( legal for trade: -10 to +40C ); storage temperature: -40 to
+80 C

Measuring channels

Load cell supply voltage

5 VAC

Sensitivity

0.6 V/d

Input signal

0 15mV

Unit

kg, g, t, lb, N, kN

Number of increments

Legal-for-trade: max. 6000d


Multi-range scale: 3 x 3000d
Multi-divisional scale: 3 x 3000d
Resolution unlimited in non-legal-for-trade mode

Taring

Up to 100% of full scale

Zero setting function

Max. 20% settable; automatic zero tracking 0.5d/sec ( selectable ) auto-zeroing selectable)

Load cell impedance

Min. 47 ( corresponding to 8 x 380 L/C, or > 20 RT load cells / 4000 )

Date/time

Real-time clock (RTC), min. 7 days backup

Housing

Stainless steel 1.4301; protected to IP 65, desk-top or wall-mount

Binary inputs

4 x optocouplers, 18 - 36 VDC, typ. 5 mA


2 x NAMUR, max. 5V

Binary outputs

4 x Relais, 230 VAC, 60W max.


1 x optocouplers, 18 - 36VDC, max. 50 mA

Analog output

1 x 0(4) 20mA, 12 Bit, max. impedance 500 W

Serial interfaces

Interfaces for printer, EDP or secondary display


Interface 1
RS 232, fixed
Interface 2:
RS 232 fixed
Interface 3:
RS 485 2/4-wire
Max. baud rate: 19,200

Secondary display
protocols

DTA
DDP 8861
DDP 8850

EDP protocols

Siemens 3964R
S5 (RK512)
Schenck DDP8672 standard protocol
Schenck DDP8785 poll protocol

Ethernet interface

10/100Mbaud, on board

USB interface

On board

Fieldbus protocols
(optional)

Profibus DP-V0 Device Net


MODBUS

Further Options

PC-Keyboard (USB)
Legal-for-trade memory

DISOMAT Opus System Manual


SCHENCK PROCESS

BV-H2310GB / 0628

29

5.11 Control unit

Spare parts

Spare parts

Name

Type

Material No.

DISOMAT Opus Maxi, stainless steel instrument with a flexible membrane keyboard,
21 keys

VKG 20700

V040000.B01

DISOMAT Opus Mini, stainless steel instrument with a flexible membrane keyboard,
9 keys

VKG 20710

V040001.B01

DISOMAT Opus top-hat rail machine without a keyboard

VEG 20700

V040002.B01

Basic units

Options
Connection PROFIBUS

VPB 020

V040030.B01

Connection DeviceNet

VCB 020

V 40031.B01

Displaced PC keyboard (USB), German

VTT28001

V040045.B01

Displaced PC keyboard (USB), English

VTT28002

V040045.B02

Legal-for trade memory

VMM 20490

V029352.B01

Accessories

Spare Parts
Mainboard incl. CPU

V040011.B01

Display

V023489.B01

Keyboard VTT 700 for DISOMAT , 21 keys

V040040.B01

Keyboard VTT 700 for DISOMAT , 9 keys

V040041.B01

30

BV-H2310GB / 0628

System Manual DISOMAT Opus


SCHENCK PROCESS