Sei sulla pagina 1di 27

Innovative Solutions for Non Intrusive

Inspecting of Insulated Objects

ing. Mark de Waard


Project Manager
Applus RTD

Contents

Introduction Applus RTD

Non Intrusive Inspection

Principle of RTD-INCOTEST
Top 5 Applications

|2

Introduction Applus RTD


RTD was Founded in 1937 in the Netherlands
Part of the Applus Group in 2006
Specialized in Non-Destructive Testing (NDT) and
Inspection Solutions

|3

Introduction Applus RTD

|4

Non-Intrusive means

Examine installation parts whenever you want while inservice


No unnecessary destruction of insulation or other
Status on interior/exterior of equipment
Know what is happening before a maintenance shutdown

|5

Minimizing Downtime

Common approach

Planned downtime

Extended
downtime

Last minute
defects are found

The Applus RTD approach

Early in-service
inspection

Downtime is shorter as you know exactly


where to look without last minute surprises

|6

In-Service Spot Check


What is UT spot check?
Wall thickness measurement at one single point
Mapping according to grid
Only global degradation; detection of local corrosion is
sheer luck

A
B

D
C

RUN
|7

In-Service Spot Check


Alternative RTD-INCOTEST?
Average Wall Thickness screening in one single area
Mapping according to grid
Only global degradation; detection of local corrosion is
sheer luck

|8

Principle of RTD-INCOTEST

INsulated COmponent TESTing,


by means of Pulsed Eddy Current (PEC)

|9

Principle of RTD-INCOTEST

Low Alloy Carbon Steel (ferromagnetic)


Wall Thickness 6-65 mm
Insulation Thickness <200 mm

SS, Al or Fe Sheeting Types


Temp. -150 C to 500 C

Minimum Pipe Diameter 50 mm (2)


Note: certain combinations may limit application range

| 10

Principle of RTD-INCOTEST

Sensor selection diagram - none, alu & SS sheeting

Wall thickness [mm]

70
60
50
40
30

P1.5-04

20

V1.0-02
P0.5-1

10
0

P0.25-0

25

50

75
____

100
MKI

125

150

Lift-off [mm]

_____

175

200

225

250

MKII

| 11

Principle of RTD-INCOTEST
Standard probes

50mm

| 12

Principle of RTD-INCOTEST

Time

| 13

Principle of RTD-INCOTEST

| 14

Principle of RTD-INCOTEST
Evaluation
Numbers

AWT [%]

Inspection
Grid

Eddy Current
Decay

| 15

Top 5 Applications
Sphere Legs
Piping
Vessels and Tanks
Columns
Sub Sea Applications

| 16

Top 5 Applications Sphere Legs

| 17

Top 5 Applications Sphere Legs

| 18

Top 5 Applications Piping

| 19

Top 5 Applications Vessels and Tanks

| 20

Top 5 Applications Columns

| 21

Top 5 Applications Sub Sea

Off-shore = On-shore for RTD-INCOTEST


| 22

Top 5 Applications Sub Sea

| 23

Why RTD-INCOTEST
Conventional

Down time
Scaffolding
Insulation Removal
Surface preperation
Inspection
Apply Insulation

RTD-INCOTEST

On stream
Rope Access or
Extension Tool
Directly on Insulation

| 24

Screening and follow-up

False Call

Severe Corrosion!
| 25

Reporting RTD-INCOTEST

| 26

Corrosion Detection
Screening Tool
No Direct Surface Contact Needed
No Surface Preparation Needed
On-Stream

Saves Time, Costs* and Risk


*NOTE: RTD-INCOTEST examination is part of integral inspection approach, never stand alone.