Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
H RC
L .2)
E N CT E R F&L UA L FS T E N CS E F O (250
WA E M A NL E M E N C K W I
(SE CAL E R CLO
TH LO UNTE
measurIT technologies
ENG CO
U-L
2.50 ]
S
NIC
4.30 ]
TRO
ELEC
ART
[120X
SM
[109 LEL
MA RAL
T PA
4.30 ]
[109 FCI GF Series: FLA FLOW
TO 9
11.1 .2)
PT T (284
1" NIT POR 4.73 ]
D U [120
N
CO
TH
EAR ND 4)
G RO
U (25.
1.0"T
NPT
C H RT
1 IN IT PO Smart Thermal N P
CO NDU
3.002)
(76.
F LOW ION 3.10.7)
IR ECT (78
WD
FLO X
ESS 1/2
CKN
Single-point
CL E
SIZ HI
TUB
E ET
E/ ngth
NG
PIP
A Le FLA
3
ø1.1 AX X"
M
[29]
TES
ICA N
T IND TATIO
FCI GF SERIES
FLA RIEN
O
S ER T ING
EET WAT O U N
4.73 ]
R E M OOF, OVALSFIC M
U R R
LOS ON P APP PEC
I [120
ENCPLOSI IGHT FOR S
B EX UST TNUAL PES)
1/2
& D E MA AL TY TH
(SEPROV
3
ø4.68] ENG
U-L
AP [11
6
B
FCIFLUID COMP ONEN TS INTL
4.30 ] 2.50 ]
[109 [120X
MA
TH
X" FORL FLO
W EAR ND
U
T ICA TIONS .79) G RO
R
VE PLICA 5 (0
W AP .312 2B NPT
W FLO 4x 0 UNC– C H RT
1 IN IT PO
FLO –18
TAL N CON
DU
I Z ON TATIO
O R IEN
H OR N
W OW
FLO SH
CL
T
E/
PIP
AL
ION
OPTPLAY
DIS
9.75.7)
(247
Mass Flow Metering
3)
(37. 1/2
B
1.47
TY P
3) 7.69.3)
CS
(37. 6
1.47
for Gas Applications. (195 B
TYP
ESS 1/2
HI CKN
ET
NG
FLA
2.706) 3
ø1.1 AX X"
(68. M
S [29]
5.4) 6.13.7) ® ATE
DIC TION
(2
1.0"T (155 T I N T A
FLA RIEN
NP O
S ER T I NG
EET WAT MO
UN
4.73 ]
R E M OOF, OVALSFIC
U R R
LOS ION PT APP SPEC
I [120
3.002)
(76.
MeasurIT O F, Technologies ENCPLtd.
L OS TIGH FOR
P R O Craan, ES) EX UST NUAL PES) email: info@measurIT.com Phone: +353 (0) 53 942 8962
ION T Y P Craanford, & D E MA AL TY H
L O S VA L S OVA L 9 0 º www.measurIT.com Fax: +353 (0) 53 942 8963 -LENGT
T S E X P
P P R A PGorey,
O P AT E DCo. Wexford, Ireland
R (SEPROV ø 4.63] U
MEE HT G
A F I C R OT
IC E TY AP [118
URE T TI SPE OSUR CLARI
LOS DUS OR L R
E N CT E R & UA L F T E N CS E F O
WA M A N N
ME KWI 0 .50
measurIT technologies
The GF Series Gas Mass Flowmeters combine FCI’s highly length. Flange connections and field retractable packing gland
reliable Thermal Dispersion, no-moving-parts flow element design assemblies are also available.
with an advanced microprocessor-based programmable transmitter. Flow sensitivity ranges from 0.25 to 1600 SFPS (ft/sec at a
Performance and durability are unmatched in tough industrial appli- standard temperature of 70°F and pressure of 14.7 psia) or 0.08 to
cations ranging from exhaust stack gas to digester gas to hydrogen 487.7 NMPS [m/sec at a normal temperature of 21.1°C and pres-
make-up gas flow metering. sure of 1.013 bar (absolute)].
Reliability, Flexibility in Industrial Applications The GF92 Inline Model The GF92 is used for gas mass
The GF Series Mass Flowmeters are available in two models: the flow metering in pipe lines or tubing sizes from 0.125 to 3 inches
GF90 with an insertion flow element and the GF92 with an inline (0.3175 to 7.62 centimeters). It has a standard body length of 7.25
flow element. Both models feature standard 316 stainless steel, inches (18.4 centimeters) for installation in 1 inch (2.54 centimeters)
nickel braze construction. Corrosion- and abrasion-resistant flow tubes and 12 inches (30.48 centimeters) for 1.5 to 3 inch (3.81
alloys and all-welded construction are available for select service to 7.62 centimeters) pipe sizes. Custom lengths are also available.
in harsh process environments. Flow sensitivity ranges from 0.006 to 2000 SCFM (ft3 /min at a
FCI’s advanced constant power Thermal Dispersion technology standard temperature of 70°F and pressure of 14.7 psia) or 0.01 to
provides the GF Series Mass Flowmeters with turndowns up to 1000:1, 3398 Nm3/h [m3/hr at a normal temperature of 21.1°C and pressure
repeatability of ±0.5% reading or better, and flow rate accuracy of of 1.013 bar (absolute)]. Contact FCI or an FCI representative for
±1% reading plus 0.5% full scale. the specific flow range sensitivity for your application.
The GF Insertion Model The GF90 is available for use Smart Electronics The GF Series’ microprocessor-based
in ducts or pipe sizes with a suggested minimum 2.0 inch (5.1 cm) electronics are easily addressable via a built-in keypad or through
nominal inside diameter. The standard flow element has a 1 inch the serial ports and allow complete in-field reconfiguration to the
male NPT process connection and an application specific insertion instrument’s performance parameters (i.e., the changing of relay set
www.measurIT.com
measurIT technologies
points, output zeros and spans, display units, and installation and GF Series Top Level Block Diagram
operation parameters within the calibrated instrument range).
RS-232C serial port provides the ability to interface with a computer Display
Output
Keyboard
Input
or any ASCII-oriented terminal.
Two independent analog outputs can be set in the field.
Modes include: 4-20 mA, 0-10 Vdc, 0-5 Vdc, or 1-5 Vdc. Process Sensor
Excitation
Analog
Output
flow rate, temperature and all GF Series functions are simultaneously Flow
available through the RS-232C serial ports. Computer
Sensor Relay
Data
Smart Features Outstanding features of FCI’s GF Series Acquisition
Output
trouble shooting and other critical instrument functions. 2.0 PORT SET-UP 3.0 DISPLAY SET-UP 4.0 MISCELLANEOUS
Built-In Testing and Diagnostics. Built-in testing and diag- 1= Analog Output
2= Relays
1= Flow Set-up
2= Temperature Set-up
1= Set Group
2= Corrector Set-up
3= Comm Output 3= Totalizer Set-up 3= Password Set-up
nostic capabilities ensure accurate and reliable performance.
5.0 VERIFY
4= Aux Output 4= Sample Rate 1= All
2= Flow
Diagnostics include out of range detection and forced relay status. 3= Totalizer
4= Area
Non-Volatile Memory. Non-volatile memory prevents the loss of 5= Temperature
6= Ports
7.0 CALIBRATION
valuable application data and totalized flow due to loss of power.
7= Relay
1= Show Delta R 8= Calibration
2= Show Raw Data 9= Corrector
Security. Pass-code protection offers security against both unau- 3= Set Calibration
www.measurIT.com
measurIT technologies
Typical GF90/GF92 Mass Flow Metering Applications Hydrogen Make-up Gas
Flare Gas Natural Gas Pipeline Transmission
Combustion Air to Boilers & Furnaces Compressor Fuel
Preheater Air to Boilers & Furnaces Wastewater Digester Gas or Biogas
Fuel Gas Process Gas
Scrubber Balancing Heavy Industrial HVAC
Landfill Vapor Recovery Nitrogen Purge
Exhaust Stacks Other Gas Applications
ø4.63 4.73
[118] [120] ø1.13 1/2 X"
[29] Max
X" 6
4.30
Chassis [109]
Ground
Lug
2.50
[120] U-Length FLOW
Max For
ø2.06 1 Inch NPT Horizontal Vertical Flow
[52] Flow Orientation FLOW
Conduit Port Applications
Shown
Earth
Ground
1 Inch NPT Flat Parallel
4.73 to Flow
Conduit Port [120]
CL
FLOW
A Length
1/2 B
B 6
SMART ELECTRONICS
11.19 9.75
[284.2] [247.7]
1.47 TYP
[37.3]
3.10 1.0 [25.4] 2.70
NPT 7.69 1.47 TYP
[78.7] [68.6] [195.3] [37.3]
3.00
[76.2] 6.13
[155.7]
www.measurIT.com
measurIT technologies
www.measurIT.com
measurIT technologies
Test and Calibration Laboratory Fluid Components profiles from laminar to turbulent to conditioned are generated to
Intl maintains an extensive, instrument test and calibration labora- duplicate actual field conditions. Flow rates from 0 to 20,000+ SCFM
tory at its headquarters in San Marcos, California. Utilizing the latest (0 to 34,000 Nm3/h), velocities from 0 to 800 SFPS (0 to 240 NMPS),
in advanced, computerized data acquisition sys tems and calibration pressures from vacuum to 3000 psig [200 bar(g)], and tempera-
test equipment, this facility permits comprehensive product devel- tures from -100º to +900ºF (-70º to +480ºC) are available.
opment, testing, and calibration. Any FCI product can be calibrated
in accordance with cus tomer specifications. Laboratory standards On-Site Calibration and Training In-situ calibration
are maintained with NIST (National Institute of Standards and is available from FCI’s Field Service engineers where precise test
Technology) traceable Cavitating Venturis (CVs) and precisely cali- and calibration is accomplished in actual media conditions.
brated, pressure and temperature corrected turbine flowmeters. FCI’s Training Department can provide on-site or at the
Combustible and non-combustible gas calibration flow factory Product Knowledge Workshops for our customers. The
stands allow for the calibration of FCI products in a wide range of workshops cover installation, setup, and troubleshooting skills,
gases and gas mixtures from flow stand line sizes as small as 1/8 and include hands-on exercises using real products, under actual
inch to 30 inches (3 to 760 mm) in diameter. A variety of flow operating conditions.