Sperre Air Compressor

Technical Documentation
CUSTOMER: CORPORACION ELECTRICA DEL
ECUADOR CELEC EP
HULL/ VESSEL: POWER PLANT SANTA ELENA II
SPERRE ORDER CONF.: 486856
A STARTING AIR COMPRESSOR

1 x HL2/160

Final
Working
Approval

20.11.13

ISSUE

DATE

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail:industri@sperre.com

TOP

FHJ

PREP. BY

CHECK

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail:rotterdam@sperre.com

Sperre Asia PTE LTD


Tel +65 763 63 00
Fax +65 763 18 11
E-mail:asia@sperre.com

Sole suppliers of
genuine spare parts

LIST OF DRAWINGS

STARTING AIR COMPRESSOR

1 x HL2/160

No.

Type /Dwg.

A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16

Description
General arrangement
Installation diagram
Air compressor data sheet
El. Motor data sheet
El. Wiring diagram
El. Part list
Dimension sketch, starter panel
Non-return valve, KV-48
Oil & water separator, V-23-1
Solenoid drain/ unloading valve, H.P.
Pressure switch, start/ stop
Thermo switch
Oil level switch
Vibration damper, A2
Flexible hose, 1 Bsp
Recommended lub. oil list

G03-0007
D03-0007
HL16-114
M7336
E20202
E20202005
E00009-V.3
3-2828
3-3197
322H
PRS-30
TMS-80
VH 600M
4-1813

Part No.

4492
1941
4332
7756
7746
4356
4606
4598

Electric Motor
Data Sheet
Part no.

Manufacturer & Type


Manufacturer
Model

Construction
ABB
M3AA 200 MLB6

Supply
Volts/Cycles/Phases
Rated current, In
Starting current

440V / 60Hz / 3
45,9 A
6.1 x In

Output
Rated power
Power factor at FL (cos)
Efficiency at FL
Speed synchronous / FL

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail:industri@sperre.com

7336

Size and dimentions according to


Design (IEC 60034-7)
Frame size (IEC 60072)
Protection (IEC 60034-5)
Insulation class (IEC 60085) / Temp. rise
House material
Bearing greasing
Bearings DE/SPERRE part no.
Bearings NDE/SPERRE part no.
Weight

IEC 60072
IMB3
200M
IP55
F/B
Aluminium
Acc. to instr.man
63122ZC3/6322
62102ZC3/6333
218 kg

Installation
27.0 kW
0.84
91.7%
1200/1180RPM

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail:rotterdam@sperre.com

Starting method
Duty type
Rotation (seen against shaft end)
Wiring connection
Cable gland entries

Sperre Asia PTE LTD


Tel +65 6763 63 00
Fax +65 6763 18 11
E-mail:asia@sperre.com

DOL / Y-D
S1
CW
DELTA
2xM40/1xM16

Sole suppliers of
genuine spare parts

Comment

Program description:
The starter is designed with a MAN 0 AUT switch,
In MAN mode the compressor will run regardless of the start / stop pressure switch. It is not recommended to leave the compressor
running unattended in MAN mode although the parameters temperature, lub. Oil and motor overload is surveyed.
In 0 mode the compressor is switched off, but the starter is still powered.
In AUT mode the compressor is controlled by the start / stop pressure switch.
The starter is equipped with a common alarm signal lamp and a common alarm signal output. The alarm signal is a voltage free contact
programmed to be closed when the compressor condition is normal. This means that the alarm signal is open if the PLC is not running, or
there is a fault condition detected. When an existing alarm condition and a new alarm occurs, the remote alarm output goes from open to
close for one second before returning to open.
Following parameters will give alarm:
High temperature. It the temperature exceeds the setting of the temperature switch the compressor will stop and alarm will be given. The
alarm will remain until the reset button is pressed. The text HIGH TEMPERATURE will be displayed on the PLC and will remain in the
display until the reset button is pressed.
Lubrication oil failure. If the Lub. Oil level / pressure falls under the setting of the Lub. Oil switch the compressor will stop and alarm will be
given. The alarm will remain until the reset button is pressed. The text LUB. OIL FAILURE will be displayed on the PLC and will remain in
the display until the reset button is pressed.
El-motor overload. If the thermal overload relay releases, the compressor will stop and alarm will be given. The alarm will remain until the
thermal relay is reset. The text EL_MOTOR OVERLOAD will be displayed on the PLC and will remain in the display until the thermal
relay is reset.
Emergency stop. If the emergency stop push button is activated, the compressor will stop and alarm will be given. The alarm will remain
until the emergency stop push button is released and the reset button is pressed. The text EMERGENCY STOP ACTIVATED will be
displayed on the PLC and will remain in the display until the reset button is pressed.
The progtam is designed to autostart after blackout if the compressor is set to AUT mode, timer B2 will delay the start. If the compressor
is in MAN mode and there is a power blackout then the compressor will not restart when the power returns, but have to be switched to 0
and back to MAN (or AUT).

The starter is designed with an emergency run switch. When this switch is operated the PLC is overridden, and the alarm functions are
therefore not active.
This switch is intended for emergency run only and the compressor must not be left running unattended.
The program contains an hour counter with a time to service function. When the compressor is running the hour counter is shown in the
display. When the service timer have counted down to 0 the alarm lamp will go flashing to indicate time for service. To reset service
indication press reset button.

Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

Project:
Installation:
File:

E20202.lsc

Customer:
Diagram No.:
Page:

High

B002
Trg

hi

B018
B019/3

Rem = off
20:00s+ En B035

B16
I1

(S0 Emcy Stop)

B017

RS

Par

&

I4
I2

(S1 Man)

Rem=Off

&
B022

2/B029/Trg
B001

>1

Trg

I5

(S1 Aut)

B002

B004

Rem=Off

B023

X1

Rem = off
01:00s-

&

Prio = 6
Quit = off
STARTUP IN
PROGRESS
(B002-Cur)
(B002-On-)

(F1 Overload)

B025

Par

Rem = off
30:00m+
01:00s

Q1

(F13 Oil Level)

B014

&
I6

(F12 Temp)

Q2
B019

I
B002
I4

&

B007
R

B010

I4

&

En

&

Par

MI= 500h 0m+


OT= 0h 0m
Q->0=R+En

B013

B009/R
B017/3
B010/1
B022/4
Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

B034

>1

En
Inv

B015
2/B037/Trg

>1

B032
En

Rem = off
00:50s00:50s
B020

Q3

>1

Prio = 4
Quit = off
LUB. OIL
FAILURE

RS

Par

Rem = off

Ral

2/B036/Trg

S
R

M1

Par

B06
B008

(S3 Reset)

(K1 Compressor)

B024
P

Par
Prio = 1
Quit = off
B011 EL-MOTOR
Trg
B09
OVERLOAD S
T
I4
R RS
Par
Rem = off
Rem = off
03:00s+

B014/4

I7

(Y3 Drain Valve)

En

Par
Prio = 5
Quit = off
PRESS RESET
AFTER BLACKOUT IN MAN.
B031 OPERATION
En

Par

Q2

Inv

Rem = off
05:00s+

>1

En

B012
En

B003

&

B024/En

Trg

B021
R

I3

RS

Par
Prio = 0
Quit = off
HOURCOUNTER
(B007-Tot
TIME TO
SERVICE(B007-Ti
B005

&

M2

B030

Par

I4

(F11 Start/Stop)

B023/En

B020/3

Par

B026/1

Prio = 3
Quit = off
EMERGENCY
STOP
B25 ACTIVATED

B026

B002

I8

X2

En

Par

B035
B033
En
P

Par
Prio = 2
Quit = off
HIGH
TEMPERATURE
Project:
Installation:
File:

(H3 Alarm)

E20202.lsc

B027

M2

>1

2/B038/Trg

Customer:
Diagram No.:
Page:

1/2

B001/3
2/B028/1

1/B016 Trg B029


T

Rem = off
01:00s+
1/B031 Trg B036
T

Rem = off
01:00s+
1/B009 Trg B037

B039

M3

>1

1/M2

B028

Q4

>1

Rem = off
01:00s+
1/B006 Trg B038
T

Rem = off
01:00s+

Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

Project:
Installation:
File:

E20202.lsc

Customer:
Diagram No.:
Page:

2/2

(Remote Alarm)

Block Number (Type)

Parameter

B002(On-Delay) :

Rem = off
20:00s+

B005(On-Delay) :

Rem = off
05:00s+

B006(Latching Relay) :

Rem = off

B007(Hours Counter) :

MI= 500h 0m+


OT=
0h 0m
Q->0=R+En

B009(Latching Relay) :

Rem = off

B011(On-Delay) :

Rem = off
03:00s+

B012(Asynchronous Pulse Generator) :

Rem = off
30:00m+
01:00s

B016(Latching Relay) :

Rem = off

B018(Message texts) :

Prio = 0
Quit = off
HOURCOUNTER
(B007-Tota)
TIME TO
SERVICE(B007-Time)

B021(Off-Delay) :

Rem = off
01:00s-

B023(Message texts) :

Prio = 6
Quit = off
STARTUP IN
PROGRESS
(B002-Curr)
(B002-On-D)

B024(Message texts) :

Prio = 5
Quit = off
PRESS RESET
AFTER BLACKOUT IN MAN.
OPERATION

B025(Latching Relay) :

Rem = off

B029(Wiping relay (pulse output)) :

Rem = off
01:00s+

Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

Project:
Installation:
File:

E20202.lsc

Customer:
Diagram No.:
Page:

Block Number (Type)

Parameter

B031(Message texts) :

Prio = 1
Quit = off
EL-MOTOR
OVERLOAD

B032(Message texts) :

Prio = 4
Quit = off
LUB. OIL
FAILURE

B033(Message texts) :

Prio = 2
Quit = off
HIGH
TEMPERATURE

B034(Asynchronous Pulse Generator) :

Rem = off
00:50s00:50s

B035(Message texts) :

Prio = 3
Quit = off
EMERGENCY
STOP
ACTIVATED

B036(Wiping relay (pulse output)) :

Rem = off
01:00s+

B037(Wiping relay (pulse output)) :

Rem = off
01:00s+

B038(Wiping relay (pulse output)) :

Rem = off
01:00s+

Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

Project:
Installation:
File:

E20202.lsc

Customer:
Diagram No.:
Page:

Connection

Label

I1

S0 Emcy Stop

I2

S1 Man

I3

S1 Aut

I4

S3 Reset

I5

F1 Overload

I6

F12 Temp

I7

F13 Oil Level

I8

F11 Start/Stop

I9
I10
I11
I12
I13
I14
I15
I16
I17
I18
I19
I20
I21
I22
I23
I24

S1
S2
S3
S4
S5
S6
S7
S8
AI1

Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

Project:
Installation:
File:

E20202.lsc

Customer:
Diagram No.:
Page:

Connection

Label

AI2
AI3
AI4
AI5
AI6
AI7
AI8
Q1

K1 Compressor

Q2

Y3 Drain Valve

Q3

H3 Alarm

Q4

Remote Alarm

Q5
Q6
Q7
Q8
Q9
Q10
Q11
Q12
Q13
Q14
Q15
Q16
AQ1
AQ2
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12

Creator:
Checked:
Date:

Torgeir
1/23/02 9:28 AM/8/7/12 11:45 AM

Project:
Installation:
File:

E20202.lsc

Customer:
Diagram No.:
Page:

Partlist
Main voltage
Control voltage
Motor rated power
Motor rated Current
Max rating of associated fuses

Ref
M1
Q1
K1
F1
A1
P2
S0
S1
S3
S7
H2
H3
T2
F4 F5
F6
F11
F12
F13
Y3
MPS: E20202005

440 V
220 V
27 kW
45,9 A
100 A

Description
MOTOR
MAIN SWITCH 55A
MAIN CONTACTOR 50A
BIMETAL 37-50A
LOGIC MODULE, PROGRAM: E20202
HOUR COUNTER
STOP PUSH BUTTON
SWITCH 3 WAY
PUSH BUTTON BLACK
SWITCH 2 WAY
SIGNAL LAMP GREEN
SIGNAL LAMP RED
TRANSFORMER 440/220V 150VA
FUSES 2A 450V
FUSES 0,5A 450V
SWITCH BOARD h:500 b:400 d:250
PRESSURE SWITCH
THERMO SWITCH
LEVEL SWITCH
DRAIN VALVE

Partnr
7336
14 747 11
66245
66323
45 103 75
43 082 09
43 032 88
43 033 23
43 032 64
43 033 -2
43 030 07
43 030 08
66 800 -2
68212
68205
24 902 12
7756
7746
4356
4332

Solenoid drain valve


Part no.

2/2 shut of valve for unloading


and drain of compressors.

4332

Technical data
Function ............... : Open when de-energized
Valve design......... : Pilot operated diaphragm valve
Poppet type pilot.
Nominal diameter. : 14.5 mm
Port sizes .............. : BSP
Mounting.............. : Direct pipe mounting
Unrestricted position
Working pressure . : Max 40 bar
Pressure drops ...... : p min. 0.3 bar for opening
p min 0 bar for closing
p max 40 bar
Flow factor ........... : Kv = 60
Weight.................. : 880 g (incl. coil)

Material specification

Electrical data - Coil

Body ..................... : Forged brass


Internal parts......... : Stainless steel,
brass and nickel
Sealing.................. : Synthetic rubber (FKM)
Valve sealing ........ : Pressure/spring loaded
seat disc (O-Ring)
against a carefully
machined nozzle provides
bubble tight sealing.
Life expectancy .... : Hundreds of thousands
of cycles.

Material......................: Encapsulated in synthetic material.


Plug connection..........: 3 pin DIN 43650A, incl. Plug with
PG11 for cable conn.
Voltage ......................: DC 24 V AC 110 V (50 and 60 Hz)
AC 220 V (50 and 60 Hz) Other
voltages on request.
Voltage tolerance .......: -10% to +15% of nominal
Class of insulation......: F
Solenoid duty .............: Continuos
Power rating...............: 8 W
Protection class ..........: IP 65

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail:industri@sperre.com

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail:rotterdam@sperre.com

Sperre Asia PTE LTD


Tel +65 763 63 00
Fax +65 763 18 11
E-mail:asia@sperre.com

Sole suppliers of
genuine spare parts

Data Sheet
Pressure switch PRS-30

Part no.

7756

Adjustable pressure switch


for control of compressor's START and STOP.
Range: 3,5 - 35 bar

Construction:
Pressure switch type ........ : Diaphragm
Fluids controlled.............. : Hydraulic oils, fresh water,
sea water, air
Weight ............................. : 0.75 kg

Adjustment:
Range of switching point ... : 3,5 - 35 bar
(50,75 - 507,5 psi)
Min. diff. at low setting ...... : 1,7 bar (24,65 psi)
Min. diff. at high setting ..... : 2,55 bar (36,97 psi)
Max. diff. at high setting .... : 20 bar (290 psi)

Design:
Max temperature.............. :
Max. permissible pressure :
Per cycle
Occasional surge
Destruction pressure ........ :
Mechanical life.................:

Installation:
Fluid connection.................. : " BSP
El. connector type ............... : DIN 43650A, 4-pin male,
plug PG11
Enclosure............................. : IP65

70C
45 bar (652,5 psi)
80 bar (1160 psi)
160 bar (2320 psi)
6
5 x 10 operating cycles

Ship approvals:
DNV, LRS, GL, BV, RINA
CE marked acc. to 89/336/EC, 92/31EEC, 93/68/EEC

50,8

3,5

2000

290

20

Range
Plage

PRESSURE SWITCH

3500

508

35

N6

PH

350

PRS-30

Electrical wiring:

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail: industri@sperre.com

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail: rotterdam@sperre.com

9
1,7

SPERRE
www.sperre.com

IEC/EN60 947-5-1
Ui : 250V
IP65IP65
AC15
Ue : 240V
Ie
:
1,5A
France
Ie : 1,5A France

Sperre Asia PTE LTD


Tel +65 67 63 63 00
Fax +65 67 63 18 11
E-mail: asia@sperre.com

2
3
1

11

900 130,5
170 24,7

12

20

13

PH- High setting point


PB- Low setting point

290

14

PB

Differential
Ecart

Part no. 7756


2000

Sole suppliers of
genuine spare parts

Data Sheet
Temperature switch TMS-80

Part no.

7746

Adjustable temperature switch


for alarm indication and shut down of compressor
Alarm: S.P. 75C, Shut down: S.P. 80C

Construction:
Temperature switch type ............. : Rigid sensor
Weight ......................................... : 0.35 kg
Environmental conditions:
Operation temperature ................. :
Enclosure ..................................... :
Vibration stability
Sinusoidal 20g, 25 Hz - 2 Hz ... :
Shock resistance
Shock 50 g/6 ms, 500 g/1 ms .. :
Free fall ................................... :

-40 to +70C
IP65, IEC 529
IEC 68-2-6
IEC 68-2-27
IEC 68-2-32

Electrical specifications:
Switch.......................................... : SPDT
Contact load: AC15 .................. : 0.5 A, 250 V
DC13 .................. : 12 W, 125 V
Adjustment:

Performance:
Setting range ..................................: 50-100C
Differential .....................................: 3C
Permissible operating temp. ...........: 200C
Installation:
Process connection.......................: " BSP
El. connector type ........................: DIN 43650A, PG11
Material:
Wetted Parts:
Sensor pocket ...: Brass
Enclosure Parts: Housing ...........: AlMGSi1
Plug fixture ......: Glass filled polyamid
Ship approvals:
DNV, ABS, LRS, GL, BV, RINA, MRS, KRS
CE marked acc. to EN 60 947-5-1

When the top cover is removed, the


range can be set with the setting-screw.
The differential is non-adjustable

Electrical wiring:

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail: industri@sperre.com

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail: rotterdam@sperre.com

Sperre Asia PTE LTD


Tel +65 67 63 63 00
Fax +65 67 63 18 11
E-mail: asia@sperre.com

Sole suppliers of
genuine spare parts

Data Sheet
Oil level switch

Part no.

Technical data:
Nominal pressure ..................... :
Weight ..................................... :
Max. medium temp. ................. :
Max. ambient temp. ................. :
Switching hysteresis ................ :
Switching-on point reffered to
center position : ........................ :
Electrical specifications:
Max. switching current .......:
Max. switching voltage .......:
Max. rating .........................:
Protection class ...................:

4356

PN25
0.35 kg
110C
80C
ca. 1-4 mm
-4 to 0 mm

1A
230 VAC/ 48 VDC
26 VA / 20 W
IP 65

Material:
Body ............................. : Brass (Cu Zn 39Pb)
Float ball ....................... : PVDF
Installation:
Process connection ....... : " BSP
El. connector type .......... : Plug connector DIN 43650 type
A ISO 4400 including cable box, suitable for cables of
outside dia. 4.5 - 7 mm.

Adjustment of the switching unit


The contacts are normally set for "normally open" operation,
i.e. the contacts are closed when the lubricating oil level is
high enough.
For adjustment, the locking screw has to be released and the
switching unit has to be moved, so that the RED arrow
(normally open operation) or the WHITE arrow (normally
closed operation) is located at the input of the cross drilling.

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail: industri@sperre.com

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail: rotterdam@sperre.com

The switching point is adjustable within the WHITE or


the RED arrow. The direction of the arrow shows that
the switching unit switches at a lower level. After
adjustment the locking screw has to be fastened again.

Sperre Asia PTE LTD


Tel +65 67 63 63 00
Fax +65 67 63 18 11
E-mail: asia@sperre.com

Sole suppliers of
genuine spare parts

Data Sheet
Flexible hoses

1.

2.

3.

A
(inch)

B
(mm)

C
(mm)

D
(mm)

E
(mm)

F
(mm)

Opening
of the
spanner
(mm)

Minimum
bending
radius
(mm)

Sperre
part no.

1
1
1
2

600
600
800
800
800
800

500
470
670
600
600
580

31
38
43
57
70
80

25
33
38
50
57
70

22
29
38
50
54
66

27
33
38
50
60
70

180
240
300
420
500
635

4595
4596
4597
4598
4599
4601

(1)

Sperre part no.


w/ one end flange

Sperre part no.


w/ both end flange

(2)
PN40

(3)
PN40

4666
4667
4668
4669
4687

(DN15)
(DN20)
(DN25)
(DN32)
(DN40)

7495
7492
7493
7494
7496

(DN15)
(DN20)
(DN25)
(DN32)
(DN40)

Hose construction :
Tube : Oil resistant synthetic rubber
Reinforcement : Two high tensile steel wire braids
Cover : Abrasion and weather resistant synthetic rubber
Temperatur range : - 40C to + 100C
Flexible hoses acc. to SAE 100 R2

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail:industri@sperre.com

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail:rotterdam@sperre.com

Sperre Asia PTE LTD


Tel +65 763 63 00
Fax +65 763 18 11
E-mail:asia@sperre.com

Sole suppliers of genuine spare parts

www.sperre.com

Sperre China
Tel +86 21 65070436
Fax +86 21 65070402
E-mail:china@sperre.com

List of recommended lub. oil


Issue date:
16.11.2007
Replace list of: 23.12.2004

Synthetic oil

Mineral oil

ANDEROL 555
BP ENERSYN RX 100
CASTROL AIRCOL SN 100
COSMO RECIPRO SX 100
DAPHNE MARINE COMPR. 100
ESSO / EXXON ZERICE S 100
ESSO / EXXON SYNNESTIC 68
FAMM CETUS DE 100
MOBIL RARUS 827
NIPPON OIL CO. FAIRCOL SA 100
STATOIL FRIDGEWAY S 100
SHELL CORENA AP 68
TOTAL LUBMARINE BARELF AL 100
STATOIL COMPWAY SX68

BP ENERGOL RC 68
CASTROL AIRCOL PD 100
CALTEX RPM COMPR. OIL 68
COSMO RECIPRO 100
ESSO / EXXON EXXCOLUB 77
FAMM COMPRESSOR OIL EP VDL 100
GENERAL COMPOL A 100
MITSUBISHI COMPR. OIL 100
MOBIL RARUS 427
PHILLIPS COMPR. OIL 68
SHELL CORENA P 68
STATOIL COMPWAY 68
TOTAL DACNIS P

Quantities, application points and intervals for lubrication oil and grease.

Sperre Industri AS
Tel +47 70 16 11 00
Fax +47 70 16 11 10
E-mail:industri@sperre.com

Sperre Rotterdam BV
Tel +31 180 463 299
Fax +31 180 463 264
E-mail:rotterdam@sperre.com

Sperre Asia PTE LTD


Tel +65 763 63 00
Fax +65 763 18 11
E-mail:asia@sperre.com

Sole suppliers of
genuine spare parts

Once every 12 months

Electric motor bearings

After first 200 hours of operation,


and then after every 1000 hours of operation

Crank case

Air
Lub. Oil for Air compressor
Grease for El.motor
Compressor
Quantity
Application
Change
Quantity
Grease
Grease
type
[Liters]
point
interval
[Grams]
Application
interval
HLF2/77
1,8
HL2/77
4,0
Bearings lubricated for life time
HL2/90
4,0
HL2/105
4,0
HL2/120
10,0
20
HL2/140
10,0
20
HL2/160
10,0
20
HV1/85
1,5
20
HV1/120
2,0
20
HV1/140 *
4,0
20
HV1/156 *
4,0
20
HV2/200
8,0
30
HV2/210
8,0
30
HV2/219
8,0
30
HV2/220
20,0
30
HV2/240
20,0
30
HV2/270
30
24,0
HV2/285
30
24,0
HV2/300
30
24,0
* Cylinder lubrication from separate oil tank. (HV1/140A and HV1/156A does not have a separate cylinder
lubrication system, and these compressor models should be run on synthetic lub. oil only).