Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Save
Specification
Magnetic Flowmeters
Electrodeless Magnetic Flowmeter
Series 10D1477
S-FL/MAG-10D1477_2
Magnetic Flowmeter
Series 10D1477
ELECTRODELESS
MAGNETIC FLOWMETER
(MICROPROCESSOR BASED)
Accuracy % of rate
2.6
3.3
6.6
10
20
SIZE
MM
ANSI Rating
Class 150
90
100
50
Class 300
30
33.33 (f/s)
Engineering Specifications
1 thru 3
16.66
Pressure
1.3
% of
cal-factor
Sizes
INCH
CALFACTOR
GPM*
25
53.7
6.0
20.0
60.0
200.0
40
1-1/2
161.1
18.0
60.0
180.0
600.0
50
268.4
30.0
114.0
300.0
1140.0
80
805.3
90.0
340.0
900.0
3400.0
100
1074.0
120.0
455.0
1200.0
4550.0
TA B L E 1 .
*NOTE: FLOW VEL (ft/s) = (GPM x 32.8) / Cal-Factor
**Useable max imum = 1.12 x Cal-Factor
S-FL/MAG-10D1477_2
Sample Specification
Materials of Construction
Meter Tube: Ceramic 99.7% Alumina.
Housing:
ME TE R WE IGHT
INCH
POUNDS
KILOGRAMS
25
11.5
5.2
40
1-1/2
16.5
7.5
50
13
5.9
80
21
9.5
100
32
14.5
Ordering Information
Specify Model 10D1477 and flowmeter size (usually
same as pipe size).
Type and class of flange being used.
Remote mounted converter.
Power source.
Output signal and maximum flow rate.
Liquid or slurry (by name, concentration, conductivity,
viscosity, operating temperature and pressure).
Environment temperature (maximum) and hazardous
classification.
S-FL/MAG-10D1477_2
10D1477
__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
09
11
12
14
15
Mating Flange
ANSI Class 150 ...................................................... P
ANSI Class 300 ...................................................... Q
DIN PIN 16 ............................................................. D
DIN PIN 40 ............................................................. F
Information Not Required ....................................... X
Electrode Material - None ................................................ A
Electrode Type - None ............................................................ 1
Flange Material - Flangeless Design .............................................. 9
Safety Classification
Unapproved Instruments - including 220/240 Vac .............................. A
FM Approved for Class I, Div. 2, Gr. A, B, C, & D;
Class II, Div. 1, Gr E, F, & G; Class III, Div. 1 ................................... K
Electrical Requirements**
Remote Mounted Converter w/Separate Model No. .................................. Y
Flowmeter Enclosure Rating
IEC 529 IP65, NEMA 4X .................................................................................... 1
IEC 520 IP67, Accidental Submergence in water
to 30 ft. for 48 hrs. ............................................................................................ 5
Fluid Temperature Range
120C (248F) ........................................................................................................... 2
Output Signal - (Remote converter required) ..................................................................... A
Output Option - (Remote Converter) ......................................................................................... 1
Communication Mode - (Remote Converter) .................................................................................. 1
Coil Drive Frequency - 15 Hz .................................................................................................................. 2
Additional Options
None
........................................................................................................................................................ 2
Mounting Hardware
Kilnger Sil Gaskets ............................................................................................................................................... C
Gylon Gaskets ...................................................................................................................................................... D
Not Required ........................................................................................................................................................ X
Converter
Required ...................................................................................................................................................................... 1
Not Required (Primary only) ........................................................................................................................................ 2
*
***
S-FL/MAG-10D1477_2
OUTLINE DIMENSIONS
METER
AND
FLANGE
SIZE
INCH
(MM)
1
(25)
1-1/2
(40)
METER
AND
FLANGE
SIZE
INCH
(MM)
2
(50)
3
(80)
4
(100)
CUSTOM
ER
FLANGE
TYPE
AND
RATING
ANSI
CLASS
150
BS 10
TBL D &
E
DIN PN
16
C DIA
INCH
(MM)
INCH
(MM)
INCH
(MM)
INCH
(MM)
INCH
(MM)
6-13/16
(173)
2-19/32
(66)
4-7/8
(124)
3-1/8
(79)
3-9/16
(90)
8-11/16
(221)
3-3/16
(81)
5-1/8
(130)
4-31/32
(126)
6-5/32
(156)
9-3/8
(238)
3-11/16
(94)
6-3/8
(162)
5-11/16
(144)
7-1/2
(190)
S-FL/MAG-10D1477_2
CUSTOM
ER
FLANGE
TYPE
AND
RATING
ANSI
CLASS
150
BS 10
TBL D &
E
DIN PN
16
C DIA
INCH
(MM)
INCH
(MM)
INCH
(MM)
INCH
(MM)
INCH
(MM)
6-13/16
(173)
2-19/32
(66)
4-7/8
(124)
3-1/8
(79)
3-9/16
(90)
7-1/2
(191)
3-9/32
(83)
6-1/8
(156)
3-13/16
(97)
4-1/16
(103)
ABB Inc.
125 East County Line Road
Warminster, PA 18974 USA
Tel: 215-674-6000
Fax: 215-674-7183
S-FL/MAG-10D1477_2
ABB Ltd
Howard Road
St. Neots, Cambs.
England, PE19 3EU
Tel: +44 (0)1480-475-321
Fax: +44 (0)1480-217-948
ABB S.p.A
Via Sempione 243
20016 Pero (Milano) Italy
Tel: +39 (02) 33928 1
Fax: +39 (02) 33928 240
6
ABB GmbH
Industriestr. 28
D-65760 Eschborn Germany
Tel: +49 (0) 6196 800 0
Fax: +49 (0) 6196 800 1849