PROPOSED INTERIOR ELECTRICAL & ALLIED WORKS FOR IIT BOMBAY

Architect - Ar. Design Ideas


ELECTRICAL & ALLIED REPAIRING & RENOVATION WORKS ESTIMATE FOR RESIDENTIAL
BUILDING TYPE - A1
BILL OF QUANTITIES FOR ELECTRICAL & ALLIED WORKS

DATE : 25TH JUNE, 2014

SUMMARY OF ESTIMATED COST OF ELECTRICAL & ALLIED WORKS


SEC.

DESCRIPTION OF ITEM

AMOUNT(Rs.)

MAIN LT PANELS /DBS

Rs.

INTERNAL LIGHTING & POWER WIRING

Rs.

LIGHTING FIXTURES

Rs.

EARTHING

Rs.

DATA (LAN) / VOICE (TELEPHONE) NETWORKING

Rs.

T.V. CABLE NETWORKING

Rs.

MISCELLANEOUS WORKS

Rs.

TOTAL - (A to H)

Rs.

Total Cost of Electrical Works

for M/s, DESIGN IDEAS

Authorised Signatory

Authorised Signatory

SUMMARY

BILL OF QUANTITIES FOR ELECTRICAL & ALLIED WORKS FOR A1


S.N.

PARTICULARS

QTY UNIT

MAIN LT PANELS /DBS

1.1

Suply and installation of 4-way, TPN, Double Door, Polystyrene type, with
Transperant Door, Raw Distribution Board (RPDB), confirming to IEC-60439-3 /
IEC-61439, IP-40 / IP-65, IK-07 / IK-09, Insulation Class-2, FR Plastic, ROHS
Compliant, surface / flush mounted on wall, interconnected wiring complete with
earthing lugs housing following switchgears : (Similar to Hanger (Golf) / Legrand
(EKINOXE TX) make)

a
b

1.2

1 no., 40A, FP MCB, as main incomer


12 nos, 10/16/25A, SP, MCB outgoing
Full Set as above - (For Item No.A-3)
Lumpsum charges for arranging temporary power supply and lighting for all the
contractor at site including the required number of tubelight fittings, suffficient
number of plug points with plug tops, providing temeporary supply arrangements
for temeparay workstations and including all the necessary safety devices like
ELCB etc. to ensure SAFE & CONTINUED supply at site.

Nos

LS

20
10

Nos
Nos

Nos

2
12

Nos
Nos

TOTAL of SECTION (A)


B

INTERNAL LIGHTING & POWER WIRING

Supply & Installation of concealed / surface point wiring using 600v grade 1.5
sqmm copper conductor PVC insulated FRLS wires (with proper R,Y,B color code)
pulled through heavy gauge PVC conduits / casing-caping laid concealed over false
ceiling or in wall chases or on the ceiling & wall surface in case of an open ceiling
and modular type switch plate, switches, etc. including ceiling rose, lamp (CFL /
Bulb) holder as required and approved by the consultant / architect / client. (Each
circuit shall not feed more than 8 points OR 800 watts as per following
configuration.)

1.1
1.2
1.3
1.4
1.5
1.6

Primary light points including the cost of 5A switch


Secondary light points looped from the primary light point
Ceiling Fan points including fan hook, anchor fastner (Hilti make only), 150w
electronic step type regulator
Two way light points including the cost of 2 no.s of 5A two way switches
Secondary 5A Plug point on lighting switch board.
Door Bell point including the cost of electronic bell as approved by client / architect
/ consultant.

Nos

1.7

Exhaust fan point consisting of 5A socket near fan and switch on light switch board

Nos

Supplying & fixing suitable size GI box with modular plate and cover in front of
surface or in recess, icluding providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection, painting etc. as required. (For T.V.
Power, Service Power Point, etc.)

Nos

Supplying & fixing suitable size GI box with modular plate and cover in front of
surface or in recess, icluding providing and fixing 6 pin 15/16 amps modular socket
outlet and 15/16 amps modular switch, connection, painting etc. as required. (For
Refridgerator, Washing m/c., Kitchen Power Points, etc.)

Nos

Supplying & fixing suitable size GI box with modular plate and cover in front of
surface or in recess, including providing and fixing 6 pin 20 amps modular socket
outlet and 20 amps modular / industrial type with MCB, connection, painting etc. as
required. (For Room A.C., Geyser, etc.)

Nos

Supplying & installation of wiring for lighting / power circuit / submain wiring
alongwith earth wire with the following sizes of PVC insulated FRLS copper
conductor, single core cable in surface / recessed PVC conduit as required :120
40
140

Rmt
Rmt
Rmt

5.1
5.2
5.3

2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (Lighting circuit)


2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (5/6A Power circuit)
2 X 4 sq.mm + 1 X 4 sq.mm earth wire (15/16 /20A Power circuit)
TOTAL of SECTION (C)

LIGHTING FIXTURES
Page 2 of 6

RATE (Inc.
AMOUNT (Rs.)
of Taxes)

S.N.

PARTICULARS

QTY UNIT

Supply & Installation of lighting fixtures with lamps as per the details below
including necessary hardware such as clamps,nuts, bolts, nails, screws and
suspension rods as required for fixing the fixtures in position as directed by
architect / consultant / client.
Note :- Sample of all type of light fixtures / fans / exhaust fans / other fittings
shall be be approved from architect / consultant / client & the sample of each
approved fixture / fittings shall be kept & maintained at site.
1

Supply & Installation of (1 X 28W) T5 (4') Decorative Tubelight having low loss
ballast & 10% THD.

16

Nos

Supply & Installation of (1 X 28W) T5 (4') Patti Tubelight without cover having
low loss ballast & 10% THD.

Nos

Supply & Installation of required size wall mounting brackets / holders for
connection to Tubelight near Patti Tubelight fitting. The fitting shall be surface
mounted on wall at the height approved by architect / client / consultant.

Nos

Supply & Installation of (1 x 11W) Mirolta Light fixture. The fitting shall be
surface mounted at the height approved by architect / client.

Nos

Supply & Installation of (1 x 9W PL) Bulkhead Light fixture. The fitting shall be
surface mounted at the height approved by architect / client.

Nos

Supply & Installation of Wall mounted exhaust fan (9" dia.) of decorative plastic
body and removable blade with louvers on the outside of approved make.

Nos

Supply & Installation of Ceiling Fan (4'/1200 mm dia) along with necessary
hardware & accessories, etc.

Nos

Supply & Installation of Ceiling Fan (3'/900 mm dia) along with necessary
hardware & accessories, etc.

Supply & Installation of Ceiling Fan (2'/400 mm dia) along with necessary
hardware & accessories, etc.

Nos

10

Supply & fixing of 1x36w CFL Wall light fitting with, with acrylic cover & all
accessories. The fitting shall be fixed to wall with angled GI bracket of required
diameter. The brackets shall be fixed with clamps to the wall. The rate shall include
6"x 6" junction box, weather proof with 4 no.s of 10A elmex terminals & a kit-kat
fuse. The rate to include connection with 3core 0.5Sq.mm cable from JB to fitting
& 36w CFL.(PHILIPS Cat. No. FGS 120 / 136 HF / WIPRO Cat. No. WSP
11136 /equivalent model in CG make)

Nos

Nos

0
0

Mtrs
Mtrs

20

Mtrs

Nos

TOTAL of SECTION (D)


D

EARTHING

Supply & Installation of earth pit comprising of 300mm x 300mm x 6mm thick GI.
plate buried at a minimum depth of 2.5 meter including necessary materials like
charcoal,salt etc as required conforming to BIS standards having brick masonary
chamber with hinged cover and watering arrangement. (General Earthing for Each
Building & Pump Room)

2
2.1
2.2
2.3

Supply & Installation of copper /GI earthing wires/strips in following sizes


8 SWG bare GI wire
12 SWG bare GI wire
(25 x 6)mm GI. Strip through PVC sleeve (Electrical Earthing) (From Electrical
Earthing Pit to Main Electrical Earthing Busbar)
TOTAL of SECTION (E)

E
I

DATA (LAN) / VOICE (TELEPHONE) NETWORKING


DATA

Supply & Laying of Cat - 6 UTP cable through 25mm PVC conduits to be laid
conceled / surface as required including the cost of PVC conduit & all necessary
hardware & accessories, etc.

80

Rmt

Supply of Single I/O Face Plate with Information outlet & MS / PVC back box if
required including all necessary hardware & accessories, etc.

Nos.

Supply & installation of 24 Port 10/100 Mbps Unmanage network switch in the
network rack alongwith all necessary hardware & accessories, etc. as required.

Nos.

Supply & installation of 6U wall mounted network rack alongwith all necessary
hardware & accessories, etc.complete as required as approved & directed by the
client / consultant at site..

Nos.

Page 3 of 6

RATE (Inc.
AMOUNT (Rs.)
of Taxes)

S.N.

PARTICULARS

QTY UNIT

Termination, Testing, Scanning, Certification and Documentation of all UTP Points


mentioned above. (For each building.)

JOB

Note :- The entire installation is to be certified/documented by the Approved


Vendor for 20 years guarantee. It is the responsibility of the Contractor to get
the installation certified/documented from Approved Vendor. No separate
cost shall be paid by the Owner for getting the installation
certified/documented and approved from Approved Vendor.
II

VOICE

Supply & Laying of 2-pair 0.5 sq mm FR PVC insulated annealed copper


conductor, unarmored telephone wire through 20/25mm PVC conduits to be laid
conceled / surface as required including the cost of PVC conduit & all necessary
hardware & accessories, etc.

80

Rmt

Supply & installation of RJ-11 1M telephone socket outlet point along with
necessary hardware & accessories, etc. complete as required.

Nos.

Supply, installation, testing and commissioning of indoor type telephone


distribution box with suitable S.S. frame for mounting tag module, cable, wires and
incorporated in 16 SWG MS box with proper lockable cover. The box should be
fixed on wall with suitable fasteners including painting & earthing. This also
includes fixing the cable, distribution chart sufficient space for the cables, wires
etc.to be provided in the box for :-

3.1

50 pair MDF with Krone module (Each Building)

Nos.

TOTAL of SECTION (F)


F
1

T.V. CABLE NETWORKING


Supply & installation of T.V. outlet point including all necessary hardware,
accessories, etc.

Nos

Supply & laying of RG-6 TV cable through heavy guage PVC conduit including all
necessary hardware, accessories, etc.

80

Rmt

Supply & laying of RG-11 TV cable through heavy guage PVC conduit including
all necessary hardware, accessories, etc.

10

Rmt

Supply & laying of 2-way Splitter box for TV cable termination including all
necessary hardware, accessories, etc.

Nos

Supply & laying of 4-way Splitter box for TV cable termination including all
necessary hardware, accessories, etc.

Nos

TOTAL of SECTION (G)


G

MISCELLANEOUS WORKS

Preparation & submission of 4 sets (Client / Concultant / Contractor / Site each) of


hard copies & soft copies in the form of e-mail / CD, of all the required Electrical
Services As Built drawings, Approved Panel GA Drawings, Panel Test Certificates
& approval from the client / consultant & Submission of testing reports, earthing
test reports, opearating manuals, warranty / guarantee cards etc. complete as
required. (All drawing's printouts shall be of A3/A2/A1 size as required.)

TOTAL of SECTION (H)

Page 4 of 6

LS

RATE (Inc.
AMOUNT (Rs.)
of Taxes)

LIST OF APPROVED MANUFACTURERS FOR LT ELECTRICAL WORKS


S.N. MATERIALS
1

APPROVED MANUFACTURERS

Moulded Case Circuit Breaker (MCCB) i) Legrand


ii) Hager

Switch Fuse Unit (SFU)

i) L & T
ii) Siemens
iii) ABB

Contactors

i) L & T
ii) Siemens
iii) Schneider

Meters

i) L & T
ii) Secure
iii) Rishabh (To be considered for Remote Metering
Option Only)

LT cable

i) KEI
ii) Finolex
iii) Havells
iv) CCI

Cable Termination

i) Dowells
ii) Comet

Cable Tray

i) Profab
ii) Metalemms
iii) Asian Ancillary Corporation

Conduit Steel / PVC

i) Precisions
ii) Supreme
iii) Diamond

Wires

i) Havells
ii) Finolex
iii) R R Kabel

10

Modular Switches & Sockets with PVC


i) Legrand - Arteor
Box
ii) MK - Wrap around plus
iii) Crabtree - Verona

Page 5 of 6

S.N. MATERIALS
11 Distribution Board, MCB & ELMCB

APPROVED MANUFACTURERS
i) Legrand
ii) Hager

12 Data Cable & accessories

i) D-Link
ii) Amp
iii) Legrand

13 Telephone cable

i) Delton
ii) Fonolex
iii) National

14 Light Fixtures with lamp

i) Wipro
ii) Philips
iii) Crompton Greves
iv) Havells

15 CFL's

i) Philips
ii) Osram
iii) Trulite

16 Ceiling Fan

i) CG (High Breez)
ii) Havells (Equivalent)

17 Exhaust Fan

i) CG
ii) Havells
iii) Almonard
iv) Alstom

18 Panel Manufacturer

CPRI & ISO Certified Only. (As approved by the


Client / Consultant.)

Page 6 of 6