Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Selection Matrix
BULLETIN DPQG-1
BULLETIN DPQG-1
MODEL:
Specifications:
Accuracy
Range Limits
Max. Static Pressure
Dial Size
Case Material
Available Body Materials
Diaphragm Material
Tube and Socket Material
Connection Size
Min/Max Ambient Temp.
Min/Max Process Temp.
IP Rating
Window
Attach to Seals
Warranty
Options
Switch Rating
Notes:
1125/1125A
1127/1128
5503
5509
1130
1131
1132
1133
1134
2-1-2% of Span
0-20 psid to 1000 psid
30 psi to 1500 psi
range dependent
412 or 6
Aluminum
NA
NA
Bronze/Brass
1
4 NPT
0/150F
0/150F
IP 53
Glass, Plastic optional
Yes
1 Year
Electric Contacts
2-1-2% of Span
0-10 psid to 1000 psid
45 psi to 1200 psi
range dependent
412 or 6
Aluminum
NA
NA
316SS
1
4 NPT Lower Only
0/150F
0/150F
IP 53
Glass, Plastic optional
Yes
1 Year
2% Ascending
0-5 psid to 150 psid
3000 psi (6000 w SS)
2% Ascending
0-5 psid to 100 psid
3000 psi
2% Ascending
0-1 psid to 60 psid
1500 psi
2% Ascending
0-1 IWD to 25 IWD
500 psi
2% Ascending
0/.6 IW - 60 IWD
35 psi
2 through 6
Stainless Steel
Aluminum, Brass, SS
Buna, Viton or EPDM
NA
1
4 NPTF
40/175F
40/175F
IP 65
Glass, Plastic optional
No
5 Years
212 through 6
Stainless Steel
Aluminum, Brass, SS
Buna, Viton or EPDM
NA
1
4 NPTF
40/175F
32/175F (3)
IP 65
Glass, Plastic optional
No
5 Years
212 through 6
Stainless Steel
Aluminum, Brass, SS
Buna, Viton or EPDM
NA
1
4 NPTF
40/175F
32/175F (3)
IP 65
Glass, Plastic optional
No
5 Years
312 through 6
Stainless Steel
Aluminum and SS.
Buna, Viton or EPDM
NA
1
4 NPTF
40/175F
32/175F (3)
IP 65
Glass, Plastic optional
No
5 Years
412
Stainless Steel
Glass Filled Nylon
Buna or EPDM
NA
1
8 NPTF
40/175F
32/175F (3)
IP 65
Glass, Plastic optional
No
5 Years
5 Weeks
$$
Wika, US Gauge
5 Weeks
$$
Wika, US Gauge
8 Weeks
$$$$
ITT Barton, Wika
8 Weeks
$$$
Wika
5 Weeks
$
Orange Research,
Midwest
5 Weeks
$
Orange Research,
Midwest
5 Weeks
$
Orange Research,
Midwest
5 Weeks
$
Orange Research,
Midwest
5 Weeks
$
Dwyer Magnehelic,
Orange Research
Pump performance,
filtration monitoring, level
measurement, flow rate
N/A
1. Duratherm for 10psi and above. 316SS for 5psi and below.
3. The diaphragm material can be exposed to temperatures as low as 40F. While exposed to extreme
temperatures the diaphragm will stiffen and effect accuracy. Once temperature returns to the normal
operating temperature the diaphragm will continue to operate without any damage to the unit.